EDTA容量法测定硫酸根离子的误差分析
引用本文:尧文元,仇荣亮.EDTA容量法测定硫酸根离子的误差分析[J].中国环境监测,1999(1).
作者姓名:尧文元  仇荣亮
作者单位:中山大学环境科学系
摘    要:系统分析了EDTA容量法测定硫酸根离子的误差产生环节,并对各个环节提出了相应的误差控制办法。文中着重分析了由移液过程和滴定过程所产生的误差,最后指出,作为测定硫酸根离子的方法标准,EDTA容量法无法保证应有的精度,应由离子色谱法取代之

关 键 词:EDTA容量法  硫酸根离子  误差分析

Error Analysis of Determining SO 2- 4 by EDTA Volume Method
Yao Wenyuan,et al.Error Analysis of Determining SO 2- 4 by EDTA Volume Method[J].Environmental Monitoring in China,1999(1).
Authors:Yao Wenyuan  
Abstract:The procedures which give rise to error in determining SO 2- 4 by EDTA volume method are analysed,and relevant measures to control them are given in this paper.The error results from the procedures of removing liquid and titration are analysed paticularly.At the end of the paper,authers point out that EDTA volume method can not guarantee the due determination precision and should be replaced by ion chromatography as a standard method.
Keywords:EDTA volume method  SO    2-    4  Error analysis  