首页 | 官方网站   微博 | 高级检索  
     

分光光度法测定水中水合肼方法检出限的优化
引用本文:丁佳.分光光度法测定水中水合肼方法检出限的优化[J].环境监控与预警,2015,7(4):19-23.
作者姓名:丁佳
作者单位:绍兴市环境监测中心站,浙江 绍兴 312000
摘    要:用对二甲氨基苯甲醛分光光度法测定水中水合肼,将显色剂用量由5.0 m L降至3.0 m L,比色皿厚度由30 mm增至50 mm,水样酸度由1 mol/L降至0.5 mol/L,同时增加低浓度校准曲线,实现对其方法检出限的优化。结果表明,优化后方法检出限由0.007 8 mg/L降至0.001 0 mg/L,精密度及加标回收率均符合规范要求,能够保证低浓度水样的准确测定。

关 键 词:水合肼  对二甲氨基苯甲醛分光光度法  检出限
收稿时间:2014/12/18 0:00:00
修稿时间:2015/5/26 0:00:00

Optimization of the Detection Limit of Hydrazine Hydrate in Water by Spectrophotometric Method
DING Ji,TENG Kai ling.Optimization of the Detection Limit of Hydrazine Hydrate in Water by Spectrophotometric Method[J].Environmental Monitoring and Forewarning,2015,7(4):19-23.
Authors:DING Ji  TENG Kai ling
Abstract:The paradime thylaminobenzaldehyde spectrophotometric method was used for the determination of hydrazine hydrate in water and its detection limit was optimized. The dose of chromogenic agent was reduced from 5.0 mL to 3.0 mL, the thickness of cuvette was increased from 30 mm to 50 mm, the acidity of the water samples was reduced from 1 mol/L to 0.5 mol/L, and the amount of sampling points at low concentrations on the calibration curve was increased all of which were used to optimize the detection limit. The experimental results showed that the optimized detection limit decreased significantly from 0.007 8 mg/L to 0.001 0 mg/L. The precision and recovery rate could both meet the requirements of the specification, which guaranteed the accuracy of the determination of water samples at low concentration.
Keywords:Hydrazine hydrate  Paradime thylaminobenzaldehyde spectrophotometric method  Detection limit
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《环境监控与预警》浏览原始摘要信息
点击此处可从《环境监控与预警》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号