首页 | 官方网站   微博 | 高级检索  
     

复三维电极生物膜反应器脱除饮用水中的硝酸盐
引用本文:范彬,曲久辉,刘锁祥,雷鹏举,孟光辉.复三维电极生物膜反应器脱除饮用水中的硝酸盐[J].环境科学学报,2001,21(1):39-43.
作者姓名:范彬  曲久辉  刘锁祥  雷鹏举  孟光辉
作者单位:1. 中科院生态环境研究中心
2. 北京市节水用水办公室
基金项目:国家自然科学基金(批准号:59978050)资助项目
摘    要:研究了以无烟煤和以颗粒活性炭为介质的复三维电极电化学-生物膜反应器脱除饮用水中硝酸盐的工艺,该工艺将复三维电化学产氢与以氢气为电子供体的自养反硝化工艺结合起来.实验表明,两种介质的反应器在不加任何有机基质时都能有效地脱除水中的硝酸盐,并且两种反应器的最大电流效率分别达到204%和185%.在水力停留时间不小于2.1—2.5h时,反应器的脱硝率接近100%.在34℃、槽压4.97V时处理21.4mg(NO

关 键 词:复三维电极-生物膜反应吕  饮用水  氢气  自养反硝化  填充介质  脱除  硝酸盐
文章编号:0253-2468(2001)-01-0039-05
收稿时间:1999/12/6 0:00:00
修稿时间:1999年12月6日

Nitrate removal from drinking water by three-dimension electrode electrochemical-biofilm reactors
FAN Bin,QU Jiuhui,LIU Suoxiang,LEI Pengju and MENG Guanghui.Nitrate removal from drinking water by three-dimension electrode electrochemical-biofilm reactors[J].Acta Scientiae Circumstantiae,2001,21(1):39-43.
Authors:FAN Bin  QU Jiuhui  LIU Suoxiang  LEI Pengju and MENG Guanghui
Affiliation:State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Scinces, Beijing 100085,State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Scinces, Beijing 100085,State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Scinces, Beijing 100085,State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Scinces, Beijing 100085 and Beijing Water Saving & Supplying Office
Abstract:Nitrste removal from drinking water through autotrophic denitrification by two bipolar-three-dimension-electrode-biofilm reactors with anthracite or GAC as medium was studied. This technique combined autotrophic denitrification process with bipolar-three-dimension-electrode hydrogen generating process. The nitrate can be removcd effectively by both reactors without adding any organic carbon. The electric current efficiency of the reactor using anthracite as medium is up to 204 %, and that of GAC is up to 185 %. As the HRT more than 2.1—2.5 hours, both reactors can get nearly 100 % nitrate removal. When treating water of 21.4 mg(NO3- -N )/L at 34℃ and 4.97V,The denitrification rate of the reactor with anthracite is 0.247 mg(NO3- -N)/cm2 of electrade surface/day,and that of one with GAC is 0.213 mg(NO3- -N)/cm2 of electrode surface/day.
Keywords:bipolar\|three\|dimension\|electrode\|biofilm reactor  drinking water  hydrogen  autotrophic denitrification  packed med
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《环境科学学报》浏览原始摘要信息
点击此处可从《环境科学学报》下载全文