首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 265 毫秒
1.
C. Cuiu  R. Halman  K. Li  R.S. Thomas  R.C. Lao 《Chemosphere》1986,15(9-12):1091-1098
Sample extracts from each section of a blank stack sampling train are portioned into two fractions, one to be used for PCDD/PCDF and PCB/CB analysis and the other for PAH/CP. The results of recovery studies for spiked compounds are presented. Developed protocols will be applied to future stack sampling programs and other environmental monitorings.  相似文献   

2.
Weber R  Sakurai T  Ueno S  Nishino J 《Chemosphere》2002,49(2):127-134
The correlation of PCDD/PCDF levels with the CO emissions in a full-scale municipal waste incinerator was assessed during a four-week measurement effort. PCDD/PCDF concentrations in fly ashes-containing more than 99% of the total PCDD/PCDF burden of the fluidized bed incinerator (FBI)-were measured and compared with the emitted CO concentrations. The CO concentration during the sampling time showed no significant correlation to the PCDD/ PCDF amount in fly ash (R2 = 0.078). However, a comparison of the time integrated CO concentration several hours before sampling lead to a correlation with the PCDD/PCDF burden. Maximum correlation was found for the time integrated CO values of 3 and 4 h before sampling (R2 = 0.467 and R2 = 0.457 respectively). This indicates a memory effect in the high temperature cooling section of several hours. Possible mechanisms leading to the memory effect are discussed. The correlation of PCDD/PCDF with CO concentration demonstrate that the combustion conditions play an important role for PCDD/PCDF formation in FBIs. However the variability in the correlation of CO to PCDD/PCDF levels show that other factors have a significant influence on PCDD/PCDF formation.  相似文献   

3.
Three laboratories participated in a PCDD and PCDF sampling experiment on the stack of a municipal waste incinerator and six laboratories examined a fly ash sample for PCDDS and PCDFS in order to assess analytical precision.

The flue gas sampling results are in agreement for the three laboratories and show that the PCDDS and PCDFS are predominantly in the gas phase, whereas emitted particulate account for 20% of the total PCDD/PCDF concentration.  相似文献   


4.
H.Y. Tong  F.W. Karasek 《Chemosphere》1986,15(9-12):1219-1224
Flyash samples were collected from the electrostatic precipitators of seven municipal refuse incinerators of four different countries. Analytical results of PCDD and PCDF in these samples shows a very similar iosmer distribution pattern for all PCDD/PCDF although concentrations of PCDD and PCDF vary. These results imply that PCDD/PCDF were formed through the same mechanism in those incinerators regardless of garbage composition or incinerator design.  相似文献   

5.
Jon Knutzen

M. Oehme 《Chemosphere》1989,19(12):1897-1909

The contamination of a fjord region by PCDD and PCDF produced from a Mg-production plant has been studied. Levels in organisms (fish, crustacea, mussels) and sediments were determined. The results allowed an estimate of the spreading of PCDD/PCDF by coastal currents. The present situation is compared with available information from other contaminated areas and with data for other contaminants in the recipient area such as hexachlorobenzene and octachlorostyrene.  相似文献   

6.
On-line detectable indicator parameters in the flue gas of municipal solid waste incinerators (MSWI) such as chlorinated benzenes (PCBz) are well known surrogate compounds for gas-phase PCDD/PCDF concentration. In the here presented work derivation of indicators is broadened to the detection of fly and boiler ash fractions with increased PCDD/PCDF content. Subsequently these fractions could be subject to further treatment such as recirculation in the combustion chamber to destroy their PCDD/PCDF and other organic pollutants' content. Aim of this work was to detect suitable on-line detectable indicator parameters in the gas phase, which are well correlated to PCDD/PCDF concentration in the solid residues. For this, solid residues and gas-phase samples were taken at three MSWI plants in Bavaria. Analysis of the ash content from different plants yielded a broad variation range of PCDD/PCDF concentrations especially after disturbed combustion conditions. Even during normal operation conditions significantly increased PCDD/PCDF concentrations may occur after unanticipated disturbances. Statistical evaluation of gas phase and ash measurements was carried out by means of principal component analysis, uni- and multivariate correlation analysis. Surprisingly, well known indicators for gas-phase PCDD/PCDF concentration such as polychlorinated benzenes and phenols proved to be insufficiently correlated to PCDD/PCDF content of the solid residues. Moreover, no single parameter alone was found appropriate to describe the PCDD/PCDF content of fly and boiler ashes. On the other hand, multivariate fitting of three or four parameters yielded convenient correlation coefficients of at least r=0.8 for every investigated case. Thereby, comprehension of plant operation parameters such as temperatures and air flow alongside concentrations of inorganic compounds in the gas phase (HCl, CO, SO2, NOx) gave the best results. However, the suitable set of parameters suited best for estimation of PCDD/PCDF concentration in solid residues has to be derived anew for each individual plant and type of ash.  相似文献   

7.
Cunliffe AM  Williams PT 《Chemosphere》2007,68(9):1723-1732
The influence of temperature on the levels of PCDD and PCDF remaining in, and desorbed from, a municipal solid waste incinerator flyash was investigated by heating the ash to between 200 and 400 degrees C under a simulated flue gas for four days reaction time. Considerable desorption of PCDD/PCDF from the flyash was seen at 275 degrees C and above. Maximum desorption occurred at 350 degrees C, with the equivalent of nearly eight times the total PCDD/PCDF concentration of the original flyash being lost to the vapour phase per unit mass of initial flyash. The I-TEQ value of the desorbed PCDD/PCDF was considerable, being over fourteen times that of the original flyash at 325 degrees C. The results indicate that formation of PCDD/PCDF on flyash deposits in the post-combustion plant of incinerators can result in the release of significant amounts of PCDD/PCDF to the flue gas stream.  相似文献   

8.
Since the publication of the first version of European standard EN-1948 in 1996, long-term sampling equipment has been improved to a high standard for the sampling and analysis of polychlorodibenzo-p-dioxin (PCDD)/polychlorodibenzofuran (PCDF) emissions from industrial sources. The current automated PCDD/PCDF sampling systems enable to extend the measurement time from 6–8 h to 15–30 days in order to have data values better representative of the real pollutant emission of the plant in the long period. EN-1948:2006 is still the European technical reference standard for the determination of PCDD/PCDF from stationary source emissions. In this paper, a methodology to estimate the measurement uncertainty of long-term automated sampling is presented. The methodology has been tested on a set of high concentration sampling data resulting from a specific experience; it is proposed with the intent that it is to be applied on further similar studies and generalized. A comparison between short-term sampling data resulting from manual and automated parallel measurements has been considered also in order to verify the feasibility and usefulness of automated systems and to establish correlations between results of the two methods to use a manual method for calibration of automatic long-term one. The uncertainty components of the manual method are analyzed, following the requirements of EN-1948-3:2006, allowing to have a preliminary evaluation of the corresponding uncertainty components of the automated system. Then, a comparison between experimental data coming from parallel sampling campaigns carried out in short- and long-term sampling periods is realized. Long-term sampling is more reliable to monitor PCDD/PCDF emissions than occasional short-term sampling. Automated sampling systems can assure very useful emission data both in short and long sampling periods. Despite this, due to the different application of the long-term sampling systems, the automated results could not be directly compared with manual results, not even in terms of measurement uncertainty. This investigation focuses on both uncertainty and repeatability of the automated sampling method. The standard 20988, developed by Internarional Organization of Standardization (ISO) can be used to estimate the measurement uncertainty. The results confirm that the uncertainties of manual and automated methods are comparable. At the same time, it is not appropriate to consider the manual method as a reference for the evaluation of the uncertainty of the automated sampling system, due to the high variability of both systems.  相似文献   

9.
Ogura I  Masunaga S  Nakanishi J 《Chemosphere》2001,44(6):1473-1487
The atmospheric bulk (dry and wet) deposition of dioxins was investigated at four locations (Tokyo, Yokohama, Tsukuba, and Tanzawa) in the Kanto region (in Japan) over one year using a stainless-steel pot. Annual average polychlorinated dibenzo-p-dioxins/polychlorinated dibenzofurans (PCDD/PCDF) deposition fluxes were estimated to be from 450 to 1300 ng/m2/yr, and the annual average TEQ fluxes from 5.7 to 17 ng-TEQ/m2/yr at the four locations. The PCDD/PCDF deposition flux was higher in winter than in summer. The deposition flux could be related to ambient temperature, particularly for less chlorinated PCDDs/PCDFs, while the deposition flux is not necessarily related to the amount of precipitation. The PCDD/PCDF deposition flux increased as the particle deposition flux increased, for the winter samples. Based on the ratio of the PCDD/PCDF deposition fluxes to the particle deposition fluxes, the contribution of the reentrainment of soil particles to the TEQ of PCDD/PCDF deposition was considered to be negligible in this region. Based on the air concentrations monitored near our deposition sampling points by the municipalities, the ratio of the annual deposition flux to the annual average air concentration was roughly estimated to be 0.082 cm/s. The range of deposition flux in the Kanto region was estimated to be from 1.5 to 31 (median: 9.8) ng-TEQ/m2/yr based on the range of air concentration data measured by the municipalities. The total annual deposition flux in the entire Kanto region was estimated to range from 50 to 900 g-TEQ/yr (median 320 g-TEQ/yr). This estimated flux was of the same order as the sum of estimated emissions from municipal solid waste incinerators and industrial waste incinerators in the Kanto region. The contributions of dioxin-like PCBs in Yokohama, Tsukuba, and Tanzawa depositions were less than 10% of the total TEQ; however, in Tokyo it was almost equal to or more than 50%.  相似文献   

10.
Gas chromatography-low resolution mass spectrometry was used to quantitate PCDD and PCDF emitted from an urban incinerator. The amounts were determinated in 17 samples collected over 9 months. Wide variability in the different sample concentrations, ranging from 2.3 mg/h to 348 mg/h for PCDD and from 3.9 mg/h to 324 mg/h for the PCDF, was observed.  相似文献   

11.
The aim of this study was to determine a new spectrum of substances that will be selected for future breast milk monitoring in Bavaria, Germany. Up to now, the analysis of breast milk in Bavaria was limited to selected organochlorine pesticides (OCP) and polychlorinated biphenyls (PCB). Information on background levels of toxicologically interesting substances, such as dioxins and dioxin-like polychlorinated biphenyls (dl-PCB) or on flame retardants, such as polybrominated diphenyl ethers (PBDE) are very limited or not available for Bavaria. We present here levels on OCP, some nitro musks, indicator PCB, polychlorinated dibenzo-p-dioxins (PCDD), polychlorinated dibenzofurans (PCDF) and dl-PCB concentrations in breast milk collected at 12 weeks post-partum of 43 primiparous mothers living in Bavaria. The average concentrations of PCDD, PCDF and dl-PCB were 4.98, 4.93 and 9.92 pg WHO-TEQ g(-1) lipid, respectively. The mean contribution of PCDD, PCDF, non-ortho and mono-ortho PCB to the total WHO-TEQ is consistently about 25% each. Furthermore the concentration on PBDE in breast milk at two sampling points, 12 weeks and 16 weeks after delivery, were determined. Overall, 19 PBDE congeners were analysed, however the level of 12 PBDE congeners were below the limit of detection. BDE-153 and BDE-47 were the predominant congeners accounting for about 66% of the total PBDE. The means of the total concentrations of PBDE (five congeners) at the first and second sampling point were 1.90 and 2.03 ng g(-1) lipid, respectively. Based on our results the overall concentrations of the analysed substances in milk samples from Bavaria are consistent with the levels of breast milk samples of other European countries reflecting the low background body burden of these compounds.  相似文献   

12.
Hart JR 《Chemosphere》2008,72(1):75-78
Emissions and inlet concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/PCDF) have been measured from a catalytic oxidizer and a thermal oxidizer. The catalyst inlet temperature was 427 degrees C. The thermal oxidizer operating temperature was 791 degrees C. Data of the toxic dioxin and furan congeners are reported. Important results of this field study are: (1) the catalytic oxidizer in this study produced an increase in PCDD/PCDF congener concentration of almost 10-fold from the inlet to the outlet (stack), thus verifying results of a previous study that evaluated only PCDD/PCDF emissions. All congeners increased from inlet to the stack. (2) The thermal oxidizer had little effect on PCDD/PCDF levels. There was a decrease in four of the congeners and an increase in 13 congeners. (3) Ambient air was the main source of PCDD/PCDFs in the stack emissions of the thermal oxidizer in this study. Laboratory investigations are needed to understand how PCDD/PCDFs are formed (and emitted) under conditions of this study.  相似文献   

13.
Ryu JY  Mulholland JA  Oh JE  Nakahata DT  Kim DH 《Chemosphere》2004,55(11):1447-1455
A model for predicting the distribution of dibenzofuran and polychlorinated dibenzofuran (PCDF) congeners from a distribution of phenols was developed. The model is based on a simplified chemical mechanism. Relative rate constants and reaction order with respect to phenol precursors were derived from experimental results using single phenols and equal molar mixtures of up to four phenols. For validation, experiments were performed at three temperatures using a distribution of phenol and 19 chlorinated phenols as measured in municipal waste incinerator exhaust gas. Comparison of experimental measurements and model predictions for PCDF isomer distributions and homologue pattern shows agreement within measurement uncertainty. The R-squared correlation coefficient exceeds 0.9 for all PCDF isomer distributions and the distribution of PCDF homologues. These results demonstrate that the distribution of dibenzofuran and the 135 PCDF congeners from gas-phase condensation of phenol and chlorinated phenols can be predicted from measurement of the distribution of phenol and the 19 chlorinated phenol congeners.  相似文献   

14.
Moore S 《Chemosphere》2002,49(2):121-125
The analysis of polychlorinated dioxins and furans (PCDDs/PCDFs) can produce erroneous results when polychloro diphenyl ethers (PCDEs) are present because they fragment and rearrange under electron ionization to give isobaric ions with PCDFs. Mass information must be generated to indicate the occurrence of possible PCDEs but uncertainty still exists if a PCDE congener has the same retention time as a PCDF congener. The metastable atom bombardment (MAB) ion source does not transfer enough energy to PCDE upon ionization to fragment the molecular ion, thus eliminating the need for PCDE tracking in PCDF analysis. Experiments were conducted with different gases, representing different ionization energies, to demonstrate that PCDE interference can be eliminated from PCDF analysis.  相似文献   

15.
The levels of polychlorinated dibenzo-dioxins (PCDDs), polychlorinated dibenzo-furans (PCDFs), coplanar polychlorinated biphenyls (coPCBs), and polybrominated diphenyl ethers (PBDEs) were measured in fish collected from San Francisco Bay in 2000 and from the California coast in 2001. The samples were composites of only the edible portions of the fish (skin on, skin off, or whole body minus head and guts) of comparable size and from distinct geographical areas. Sixty-five composite samples were analyzed for PCDD/PCDF/coPCBs, and 43 composite samples were analyzed for PBDEs. For all fish of all species from all sampling areas, the mean concentration of the sum of BDEs 47, 99, 100, 153, and 154 was 302 ng/g lipid weight, with BDE 47>100>99 approximately 154>153. For all fish of all species from all sampling areas, the mean PCDD/PCDF International Toxic Equivalent (I-TEQ) was 33.1 pg/g lipid. For the three coPCBs (77, 126, 169), the mean I-TEQ for all fish of all species from all sampling areas was 109 pg/g lipid. The highest concentrations of both PCDD/PCDF/coPCBs and PBDEs were found in the highly populated areas of San Francisco Bay, the Los Angeles area, and San Diego Bay.  相似文献   

16.
At a MSWI (municipal solid waste incinerator) plant PCDD/PCDF samples (gasphase and particulates) were taken simultaneously be a shock-freezing method in the incinerator combustion chamber at approx. 800°C and in four sampling sections in the boiler at about 490°C, 370°C, 330°C and 270°C. In this way PCDD/PCDF-formation in the flow through the boiler was determined. Two data sets were evaluated. A considerable PCDD/PCDF-formation had occurred already at boiler temperatures of about 490°C; the highest concentration, however, was found at the end of the boiler at about 300°C. The accompanying measuring program of plant parameters made the calculation of the PCDD/PCDF mass flows possible, which allowed the inclusion of the PCDD/PCDF-content in the ESP dust in the mass flow calculations.  相似文献   

17.
Open burning for waste disposal is, in many countries, the dominant source of polychlorinated dibenzodioxins, dibenzofurans and biphenyls (PCDD/PCDF/PCB) release to the environment. To generate emission factors for open burning, experimental pile burns of about 100 kg of household waste were conducted with emissions sampling. From these experiments and others conducted by the same authors it is found that less compaction of waste or active mixing during the fire - “stirring” - promotes better combustion (as evidenced by lower CO/CO2 ratio) and reduces emissions of PCDD/PCDF/PCB; an intuitive but previously undemonstrated result. These experiments also support previous results suggesting PCDD/PCDF/PCB generation in open burning - while still highly variable - tends to be greater in the later (smoldering) phases of burning when the CO/CO2 ratio increases.  相似文献   

18.
Discharge of WHO toxicity equivalents (TEQs) of PCDF/PCDDs to Frierfjorden, Norway has been reduced from an estimated sum of 50-100 kg in the period 1951-1975 to about 6-7 kg in 1976-1990, and further to about 20 g for 1991-2000. In accordance with this, the yearly monitoring since 1987 has shown considerably decreasing contamination in organisms, first highly significant in all indicator species from 1990 to 1991, then levelling off. Present concentrations thus are still high. Compared with estimated "high background" (reference) concentrations of 10 ng TEQ(PCDF/PCDD)/kg w.w. in liver of cod and in hepatopancreas ("brown meat") of crabs, Frierfjord samples in 2001 were about 60 and 70 times higher, respectively. With considerable uncertainty due to large fluctuations, the rate of yearly decrease for TEQ(PCDF/PCDD) in cod liver 1991-2001 has been calculated to 10-12%. A hypothetic target value of 50 ng TEQ/kg w.w. will not be reached until 2015-2020, possibly even later. Including contributions from dioxin-like PCBs and PCNs, the weekly maximum tolerable amount of cod liver and crab hepatopancreas from Frierfjorden in 2001 were about 2-3 g. Multivariate analysis of PCDF/PCDD congener profiles in four fish species, mussels and crabs resulted in five distinct groups, separating four of the species and grouping the remaining two together, hence demonstrating examples of species specific accumulation characteristics.  相似文献   

19.
Polychlorinated dibenzo-p-dioxins (PCDD), dibenzofurans (PCDF) and non-ortho substituted biphenyls (PCB, CB) were determined in 6 polar bear milk samples from Svalbard (Norway). For these compounds, no data for polar bears have been reported before from this region. Most of the PCDD/PCDF congeners were found at detectable levels. Concentrations expressed as 2,3,7,8-TCDD equivalents (Nordic model) were in the order of 1–3 pg/g−1 fat (0.2–1.6 pg ml−1 milk) which is comparable with ringed and harp seal blubber from the same region. On whole milk basis, concentrations were similar to those found in human milk. An estimation of the daily uptake via milk showed that the intake is lower for polar bears compared to humans. As in human milk, relatively high levels of OCDD were found in some polar bear milk samples. The PCDD/PCDF congener pattern in the milk was different to that found in polar bear fat from the Canadian Arctic. Non-ortho substituted PCB levels in polar bear milk were similar to those found in polar bear fat from the Canadian North. However, CB 77 or 169 dominated in the milk while CB 126 was the most abundant congener in fat. PCDD/PCDF levels expressed as 2,3,7,8-TE were highly correlated with the fat content of the milk. No correlation between CB and PCDD/PCDF concentrations was found. Some data indicate that PCDD/PCDF concentrations in polar bear milk decrease with increasing time after delivery.  相似文献   

20.
Background, Aims and Scope The Rocky Mountain Arsenal (RMA) is a US Army facility located northeast of Denver, Colorado that has been listed on the National Priorities List (NPL). It is currently being re-mediated under the authority of the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) and the Superfund Amendments and Reauthorization Act of 1986 (SARA). As part of the remediation activities at RMA, indications were found that a source of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) had existed on the RMA. As a result, investigations were undertaken to assess the possible nature and extent of any potential sources of PCDDs and PCDFs on the RMA site. In addition, other studies were conducted that examined PCDD/PCDF contamination in the Denver area. The goal of these studies was to examine nature and extent of PCDD/PCDF contamination both on the RMA as well as in the surrounding Denver area. The intent of this study was to characterize sources of dioxins (PCDDs) and dibenzofurans (PCDFs) at low environmental concentrations which might have originated from diffuse sources in the Denver Colorado area and in particular, the Rocky Mountain Arsenal (RMA) using Principal Component Analysis (PCA). Methods Over 200 soil samples were collected from the RMA and the Denver area. From the RMA, soil was collected as part of three studies that included a (1) random site-wide sampling of the RMA, (2) soils from the Western Tier Parcel (WTP), and (3) soils from Historic Use areas. Denver area soil samples were collected from five different land use categories: Residential, Agricultural, Open Space, Commercial, and Industrial. PCA was conducted on concentrations of 17 2,3,7,8-substuituted PCDD and PCDF congeners in 220 soil samples collected from the RMA and the Denver Front Range region. Results and Discussion PCA demonstrated the presence of possible minor sources of dioxins on the RMA. Current remediation efforts on RMA will result in the removal of these sources. Samples from the RMA were identified by the presence of a congener profile containing higher chlorinated PCDFs while the Denver Front Range areas were characterized by the presence of higher chlorinated PCDD congeners. The presence of a PCDF signature for the RMA samples does not necessarily indicate a major source of these contaminants on-site. Indeed, the relatively diffuse nature of the sample clusters would argue strongly against the presence of a single large source. Instead, the predominance of the PCDF congeners probably indicates the mixed industrial activities that took place on and near the site. Conclusion PCA results indicate that PCDD/PCDF profiles in soils collected from the RMA differed from those collected from the outlying Denver areas but that a major source of these contaminants was not present. Rather, the diffuse nature of sample clusters from the PCA indicated that the congener profile of RMA samples was most likely a result of the mixed industrial activities that historically have taken place on and near the site. PCA also indicated that many of the 'open area' (peripheral site-wide) RMA soils samples did not differ from Denver are reference congener profiles. This finding was also true for samples collected from the WTP that were essentially indistinguishable from Off-RMA reference samples. In addition, total TEQ concentrations in soils collected from WTP were similar to those measured in soils collected from the Denver Front Range areas indicating that lack of a major source of PCDD/PCDF within the WTP zones of the RMA. Recommendation and Outlook Analytical as well as statistical results of the soil congener data indicate that the WTP soils are indistinguishable from soils collected from non-industrial areas in the Denver area. This finding would support the recent 'de-listing' of the WTP from the other RMA areas and its' transfer to other authorities in the Denver area.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号