首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The U.S. Environmental Protection Agency (EPA) Quality Assurance (QA) Guidance Document 2.12: Monitoring PM2.5 in Ambient Air Using Designated Reference or Class I Equivalent Methods (Document 2.12) requires conditioning of PM2.5 filters at 20-23 degrees C and 30-40% relative humidity (RH) for 24 hr prior to gravimetric analysis. Variability of temperature and humidity may not exceed +/-2 degrees C and +/-5% RH during the conditioning period. The quality assurance team at EPA Region 2's regional laboratory designed a PM2.5 weighing facility that operates well within these strict performance requirements. The traditional approach to meeting the performance requirements of Document 2.12 for PM2.5 filter analysis is to build a walk-in room, with costs typically exceeding $100,000. The initial one-time capital cost for the laboratory at EPA's Edison, NJ, facility was approximately $24,000. Annual costs [e.g., National Institute of Standards and Technology (NIST) recertifications and nitrogen replacement cylinders used for humidity control] are approximately $500. The average 24-hr variabilities in temperature and RH in the Region 2 weighing chamber are small, +/-0.2 degrees C and +/-0.8% RH, respectively. The mass detection limit for the PM2.5 weighing system of 47-mm stretched Teflon (lab blank) filters is 6.3 microg. This facility demonstrates an effective and economical example for states and other organizations planning PM2.5 weighing facilities.  相似文献   

2.
Abstract

The U.S. Environmental Protection Agency (EPA) Quality Assurance (QA) Guidance Document 2.12: Monitoring PM2.5 in Ambient Air Using Designated Reference or Class I Equivalent Methods1 (Document 2.12) requires conditioning of PM2.5 filters at 20-23 °C and 30-40% relative humidity (RH) for 24 hr prior to gravimetric analysis. Variability of temperature and humidity may not exceed ±2 °C and ±5% RH during the conditioning period. The quality assurance team at EPA Region 2’s regional laboratory designed a PM2.5 weighing facility that operates well within these strict performance requirements.

The traditional approach to meeting the performance requirements of Document 2.12 for PM2.5 filter analysis is to build a walk-in room, with costs typically exceeding $100,000. The initial one-time capital cost for the laboratory at EPA’s Edison, NJ, facility was approximately $24,000. Annual costs [e.g., National Institute of Standards and Technology (NIST) recertifications and nitrogen replacement cylinders used for humidity control] are approximately $500. The average 24-hr variabilities in temperature and RH in the Region 2 weighing chamber are small, ±0.2 °C and ±0.8% RH, respectively. The mass detection limit for the PM2.5 weighing system of 47-mm stretched Teflon (lab blank) filters is 6.3 μg. This facility demonstrates an effective and economical example for states and other organizations planning PM2.5 weighing facilities.  相似文献   

3.
Black carbon (BC) or elemental carbon (EC) is a by-product of incomplete fuel combustion, and contributes adversely to human health, visibility, and climate impacts. Previous studies have examined nondestructive techniques for particle light attenuation measurements on Teflon® filters to estimate BC. The incorporation of an inline Magee Scientific OT21 transmissometer into the MTL AH-225 robotic weighing system provides the opportunity to perform optical transmission measurements on Teflon filters at the same time as the gravimetric mass measurement. In this study, we characterize the performance of the inline OT21, and apply it to determine the mass absorption cross-section (MAC) of PM2.5 BC across the United States. We analyzed 5393 archived Teflon® filters from the Chemical Speciation Network (CSN) collected during 2010–2011 and determined MAC by comparing light attenuation on Teflon® filters to corresponding thermal EC on quartz-fiber filters. Results demonstrated the importance of the initial transmission (I0) value used in light attenuation calculations. While light transmission varied greatly within filter lots, the average I0 of filter blanks during the sampling period provided an estimate for archived filters. For newly collected samples, it is recommended that filter-specific I0 measurements be made (i.e., same filter before sample collection). The estimated MAC ranged from 6.9 to 9.4 m2/g and varied by region and season across the United States, indicating that using a default value may lead to under- or overestimated BC concentrations. An analysis of the chemical composition of these samples indicated good correlation with EC for samples with higher EC content as a fraction of total PM2.5 mass, while the presence of light-scattering species such as crustal elements impacted the correlation affecting the MAC estimate. Overall, the method is demonstrated to be a quick, cost-effective approach to estimate BC from archived and newly sampled Teflon® filters by combining both gravimetric and BC measurements.

Implications: Robotic optical analysis is a valid, cost-effective means to obtain a vast amount of BC data from archived and current routine filters. A tailored mass absorption cross-section by region and season is necessary for a more representative estimate of BC. Initial light transmission measurements play an important role due to the variability in blank filter transmission. Combining gravimetric mass and BC analysis on a single Teflon® filter reduces costs for monitoring agencies and maximizes data collection.  相似文献   


4.
An investigation of high volume particle sampling and sample handling procedures was undertaken to evaluate variations of protocols being used by the U.S. Environmental Protection Agency. These protocols are used in urban ambient air studies which collect ambient and source samples for subsequent mutagenicity analysis of the organic extracts of the aerosol fraction. Specific protocol issues investigated include: (a) duration of sampling period, (b) type of filter media used to collect air particles, (c) necessity for cryogenic field site storage and dry ice shipping of filter samples, and (d) sample handling at the receiving laboratory. Six PM10 Hi-Vol samplers were collocated at an urban site in downtown Durham, North Carolina and operated simultaneously to evaluate 12 h versus 24 h collection periods and filter media choices of glass fiber, Teflon impregnated glass fiber (TIGF), and quartz fiber. Filters from the samplers plus field blanks were collected during each of 25 sampling periods. TIGF filters from two samplers were immediately placed on dry ice in the field and transported directly to cryogenic storage. TIGF, quartz, and glass fiber filters from three samplers were transported at ambient and maintained at room temperature for three to six days prior to cryogenic storage. One TIGF sample, which was collected on a previously tared filter, was subjected to controlled environment equilibration (40 percent relative humidity, 22 degrees C) for 8 to 24 h and weighed prior to cryogenic storage. All filters were subsequently stored at -70 degrees C to -80 degrees C prior to a one-time extraction and Salmonella (Ames) mutagenicity bioassay of the entire sample set.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

5.
An investigation of high volume particle sampling and sample handling procedures was undertaken to evaluate variations of protocols being used by the U.S. Environmental Protection Agency. These protocols are used in urban ambient air studies which collect ambient and source samples for subsequent mutagenicity analysis of the organic extracts of the aerosol fraction. Specific protocol issues investigated include: (a) duration of sampling period, (b) type of filter media used to collect air particles, (c) necessity for cryogenic field site storage and dry ice shipping of filter samples, and (d) sample handling at the receiving laboratory. Six PM10 Hi-Vol samplers were collocated at an urban site in downtown Durham, North Carolina and operated simultaneously to evaluate 12 h versus 24 h collection periods and filter media choices of glass fiber, Teflon® impregnated glass fiber (TIGF), and quartz fiber. Filters from the samplers plus field blanks were collected during each of 25 sampling periods. TIGF filters from two samplers were immediately placed on dry ice in the field and transported directly to cryogenic storage. TIGF, quartz, and glass fiber filters from three samplers were transported at ambient and maintained at room temperature for three to six days prior to cryogenic storage. One TIGF sample, which was collected on a previously tared filter, was subjected to controlled environment equilibration (40 percent relative humidity, 22°C) for 8 to 24 h and weighed prior to cryogenic storage. All filters were subsequently stored at ?70°C to ?80°C prior to a one-time extraction and Salmonella (Ames) mutagenicity bioassay of the entire sample set. Results indicate that the sample handling variations and collection period variables had no significant effect on recovery of organics or mutagens. However, a filter type difference was observed. The sonication extraction of organics and mutagens was significantly greater for TIGF filters than for glass fiber or quartz. Results from a second phase of study indicated differences in extracted organics and mutagens for these filter types.  相似文献   

6.
Fine PM measurements: personal and indoor air monitoring   总被引:3,自引:0,他引:3  
This review compiles personal and indoor microenvironment particulate matter (PM) monitoring needs from recently set research objectives, most importantly the NRC published "Research Priorities for Airborne Particulate Matter (1998)". Techniques and equipment used to monitor PM personal exposures and microenvironment concentrations and the constituents of the sampled PM during the last 20 years are then reviewed. Development objectives are set and discussed for personal and microenvironment PM samplers and monitors, for filter materials, and analytical laboratory techniques for equipment calibration, filter weighing and laboratory climate control. The progress is leading towards smaller sample flows, lighter, silent, independent (battery powered) monitors with data logging capacity to store microenvironment or activity relevant sensor data, advanced flow controls and continuous recording of the concentration. The best filters are non-hygroscopic, chemically pure and inert, and physically robust against mechanical wear. Semiautomatic and primary standard equivalent positive displacement flow meters are replacing the less accurate methods in flow calibration, and also personal sampling flow rates should become mass flow controlled (with or without volumetric compensation for pressure and temperature changes). In the weighing laboratory the alternatives are climatic control (set temperature and relative humidity), and mechanically simpler thermostatic heating, air conditioning and dehumidification systems combined with numerical control of temperature, humidity and pressure effects on flow calibration and filter weighing.  相似文献   

7.
Final design, calibration, and field testing have been completed for a new 1.13 m3/min (40 cfm) High-volume Virtual Impactor (HVVI). Field tests have demonstrated that the new classifier/collector works well as an accessory to the existing PM10 Size Selective Inlet high-volume samplers. The HVVI provides two fractions of PM10 mass, both of which are collected by filtration. The fine fraction (0-2.5 μm aero. dia.) Is collected on the standard 20.3 × 25.4 cm (8- × 10-in) high-volume filter; the coarse fraction (2.5-10 μm aero. dia.) is collected on a 5.1 × 15.2 cm (2- × 6-in) filter. Coarse flow through the receiver tubes is limited to 0.057 m3/min (2 cfm), 5 percent of the total flow.

The operating pressure drop across the HVVI stages Is sufficiently high to make changes In pressure across the collection filters Insignificant. The HVVI filter holder assembly facilitates loading/ unloading samples in the laboratory, thus eliminating damage due to handling filters in the field. Size separation characteristics of the HVVI agree well with those for the 16.7 L/min commercially available dichotomous sampler with the 50 percent effectiveness (cut-point) occurring at 2.5 μm. Applying laboratory-determined particle losses to the typical ambient particle mass size distribution described In Federal Register 49, 40 CFR, Part 53, Table D-3, the HVVI fine fraction total mass loss is less than 0.8 percent for liquid particles and less than 0.1 percent for solid particles; coarse fraction total mass loss is less than 2.5 percent for liquid particles, and less than 0.2 percent for solid particles.  相似文献   

8.
An annular denuder system, which consisted of a cyclone separator; two diffusion denuders coated with sodium carbonate and citric acid, respectively; and a filter pack consisting of Teflon and nylon filters in series, was used to measure acid gases, ammonia (NH3), and fine particles in the atmosphere from April 1998 to March 1999 in eastern North Carolina (i.e., an NH3-rich environment). The sodium carbonate denuders yielded average acid gas concentrations of 0.23 microg/m3 hydrochloric acid (standard deviation [SD] +/- 0.2 microg/m3); 1.14 microg/m3 nitric acid (SD +/- 0.81 microg/m3), and 1.61 microg/m3 sulfuric acid (SD +/- 1.58 microg/m3). The citric acid denuders yielded an average concentration of 17.89 microg/m3 NH3 (SD +/- 15.03 microg/m3). The filters yielded average fine aerosol concentrations of 1.64 microg/m3 ammonium (NH4+; SD +/- 1.26 microg/m3); 0.26 microg/m3 chloride (SD +/- 0.69 microg/m3), 1.92 microg/m3 nitrate (SD +/- 1.09 microg/m3), and 3.18 microg/m3 sulfate (SO4(2-); SD +/- 3.12 microg/m3). From seasonal variation, the measured particulates (NH4+, SO4(2-), and nitrate) showed larger peak concentrations during summer, suggesting that the gas-to-particle conversion was efficient during summer. The aerosol fraction in this study area indicated the domination of ammonium sulfate particles because of the local abundance of NH3, and the long-range transport of SO4(2-) based on back trajectory analysis. Relative humidity effects on gas-to-particle conversion processes were analyzed by particulate NH4+ concentration originally formed from the neutralization processes with the secondary pollutants in the atmosphere.  相似文献   

9.
The real-time ambient mass sampler (RAMS) is a continuous monitor based on particle concentrator, denuder, drier, and tapered element oscillating microbalance (TEOM) monitor technology. It is designed to measure PM2.5 mass, including the semi-volatile species NH4NO3 and semi-volatile organic material, but not to measure PM2.5 water content. The performance of the RAMS in an urban environment with high humidity was evaluated during the July 1999 NARSTO-Northeast Oxidant and Particles Study (NEOPS) intensive study at the Baxter water treatment plant in Philadelphia, PA. The results obtained with the RAMS were compared to mass measurements made with a TEOM monitor and to constructed mass obtained with a Particle Concentrator-Brigham Young University Organic Sampling System (PC-BOSS) sampler designed to determine the chemical composition of fine particles, including the semi-volatile species. An average of 28% of the fine particulate material present during the study was semi-volatile organic material lost from a filter during particle collection, and 1% was NH4NO3 that was also lost from the particles during sampling. The remaining mass was dominantly nonvolatile (NH4)2SO4 (31%) and organic material (37%), with minor amounts of soot, crustal material, and nonvolatile NH4NO3. Comparison of the RAMS and PC-BOSS results indicated that the RAMS correctly monitored for fine particulate mass, including the semivolatile material. In contrast, the heated filter of the TEOM monitor did not measure the semi-volatile material. The comparison of the RAMS and PC-BOSS data had a precision of +/-4.1 microg/m3 (+/-9.6%). The precision of the RAMS data was limited by the uncertainty in the blank correction for the reversible adsorption of water by the charcoal-impregnated cellulose sorbent filter of the RAMS monitor. The precision of the measurement of fine particulate components by the PC-BOSS was +/-6-8%.  相似文献   

10.
Passive sampling devices are popular in applications which do not require the monitoring of hourly concentrations. Nitrogen oxides are often collected using filters coated with 2-phenyl-4,4,5,5-tetramethylimidazoline-1-oxyl-3-oxide (PTIO). The filter extract can then be analyzed using flow injection analysis ion chromatography fitted with a copper/cadmium reduction column or UV–vis spectroscopy. When the latter is used to measure low concentrations of nitrogen oxides, absorbance by PTIO at the analytical wavelength of 545 nm contributes significantly. PTIO concentration on the filter also shows variation with filter storage and exposure time not accounted for in a single point blank subtraction at the analytical wavelength. A method is presented that uses a scaling factor to account for variations in concentration of PTIO on the field blank and provides a more accurate method for determining and correcting for the PTIO contribution to absorption when measuring ambient nitrogen oxide concentrations.  相似文献   

11.
This study performed a workplace evaluation of emission control using available air sampling filters and characterized the emitted particles captured in filters. Characterized particles were contained in the exhaust gas released from carbon nanotube (CNT) synthesis using chemical vapor deposition (CVD). Emitted nanoparticles were collected on grids to be analyzed using transmission electron microscopy (TEM). CNT clusters in the exhaust gas were collected on filters for investigation. Three types of filters, including Nalgene surfactant-free cellulose acetate (SFCA), Pall A/E glass fiber, and Whatman QMA quartz filters, were evaluated as emission control measures, and particles deposited in the filters were characterized using scanning transmission electron microscopy (STEM) to further understand the nature of particles emitted from this CNT production. STEM analysis for collected particles on filters found that particles deposited on filter fibers had a similar morphology on all three filters, that is, hydrophobic agglomerates forming circular beaded clusters on hydrophilic filter fibers on the collecting side of the filter. CNT agglomerates were found trapped underneath the filter surface. The particle agglomerates consisted mostly of elemental carbon regardless of the shapes. Most particles were trapped in filters and no particles were found in the exhaust downstream from A/E and quartz filters, while a few nanometer-sized and submicrometer-sized individual particles and filament agglomerates were found downstream from the SFCA filter. The number concentration of particles with diameters from 5 nm to 20 µm was measured while collecting particles on grids at the exhaust piping. Total number concentration was reduced from an average of 88,500 to 700 particle/cm3 for the lowest found for all filters used. Overall, the quartz filter showed the most consistent and highest particle reduction control, and exhaust particles containing nanotubes were successfully collected and trapped inside this filter.

Implications: As concern for the toxicity of engineered nanoparticles grows, there is a need to characterize emission from carbon nanotube synthesis processes and to investigate methods to prevent their environmental release. At this time, the particles emitted from synthesis were not well characterized when collected on filters, and limited information was available about filter performance to such emission. This field study used readily available sampling filters to collect nanoparticles from the exhaust gas of a carbon nanotube furnace. New agglomerates were found on filters from such emitted particles, and the performance of using the filters studied was encouraging in terms of capturing emissions from carbon nanotube synthesis.  相似文献   

12.
ABSTRACT

Because the Federal Reference Method for PM25 specifies the collection of ambient particles on Teflon filters, we have examined the loss of a known volatile species, particulate nitrate, during sampling. Data are presented from two studies in southern California for which parallel samples were collected by different methods. Differences in collected nitrate are modeled using an evaporation model based on the work of Zhang and McMurry. The average nitrate obtained from sampling with Teflon filters was 28% lower on average than that measured by denuded nylon filters. In contrast, cascade impactor samples were within 5% of the denuded nylon filter on average. A simple model is presented that accounts for the particulate nitrate loss from Teflon filters either by scavenging nitric acid and ammonia in the sampler inlet or by heating the filter substrate during sampling. The observed magnitude of loss is explained by any of the following situations: (1) 100% nitric acid and ammonia vapor loss in the inlet, (2) 5 °C heating of the filter substrate above ambient temperature during sampling, or (3) a combination of these factors, such as 50% vapor loss in the inlet and 3 °C heating of the filter.  相似文献   

13.
The performance of Teflon-coated glass fiber filter media (Pallflex Emfab TX40) is evaluated for particulate matter (PM) sampling of residential wood heating devices in a dilution tunnel. Thirty samples of varying duration and PM loading and concentration were collected from an U.S. Environmental Protection Agency (EPA) Method 28 dilution tunnel using dual Method 5G sample trains with untreated glass fiber and Emfab filters. Filters were weighed soon after the end of sampling and again the next day after equilibration at 35% relative humidity (RH). PM concentrations from both types of filters agreed very well with 1-day equilibration, demonstrating that Emfab filters are appropriate for use in measuring PM from residential wood burning appliances in a dilution tunnel and have performance equal to or better than the glass fiber filter media. Agreement between filter media without equilibration was erratic, with PM from glass fiber filter samples varying from slightly less than the Emfab samples to as much as 2.8 times higher. Some of the glass fiber filters lost substantial mass with equilibration, with the highest percent loss at lower filter mass loadings. Mass loss for Emfab samples was a small percentage of the mass and very consistent across the range of mass loadings. Taken together, these results may indicate water uptake on the glass fiber media that is readily removed with 1-day equilibration at moderate RH conditions.

Implications: EPA regulations now allow the use of either glass fiber or Teflon filter media for wood appliance PM emission testing. Teflon filter media minimizes the potential for acid-gas PM artifacts on glass fiber filters; this is important as EPA moves toward the use of locally sourced cordwood for testing that may have higher sulfur content. This work demonstrates that the use of Teflon-coated glass fiber filters can give similar PM measurement results to glass fiber filters after 1 day of equilibration. With no equilibration, measured PM from glass fiber filters was usually higher than from Teflon-coated glass fiber filters.  相似文献   


14.
A cost-effective weighing chamber for particulate matter filters   总被引:1,自引:0,他引:1  
Particulate matter (PM) is a ubiquitous air pollutant that has been receiving increasing attention in recent years due in part to the association between PM and a number of adverse health outcomes, including mortality and increases in emergency room visits and respiratory symptoms, as well as exacerbation of asthma and decrements in lung function. As a result, the ability to accurately sample ambient PM has become important, both to researchers and to regulatory agencies. The federal reference method for the determination of fine PM as PM2.5 in the atmosphere recommends that particle-sampling filters be conditioned and weighed in an environment with constant temperature and relative humidity (RH). It is also recommended that vibration, electrostatic charges, and contamination of the filters from laboratory air be minimized to reduce variability in filter weight measurements. These controls have typically been maintained in small, environmentally controlled "cleanrooms." As an alternative to constructing an elaborate cleanroom, we have designed, and presented in this paper, an inexpensive weighing chamber to maintain the necessary level of humidity control.  相似文献   

15.
INTENTION, GOAL, SCOPE, BACKGROUND: As the strong negative health effect of exposure to the inhalable particulate matter PM10 in the urban environment has been confirmed, the study of the mass concentrations, physico-chemical characteristics, sources, as well as spatial and temporal variation of atmospheric aerosol particles becomes very important. OBJECTIVE: This work is a pilot study to assess the concentration level of ambient suspended particulate matter, with an aerodynamic diameter of less than 10 microm, in the Belgrade central urban area. Average daily concentrations of PM10 and PM2.5 have been measured at three representative points in the city between June 2002 and December 2002. The influence of meteorological parameters on PM10 and PM2.5 concentrations was analyzed, and possible pollution sources were identified. METHODS: Suspended particles were collected on Pure Teflon filters by using a Mini-Vol low-volume air sampler (Airmetrics Co., Inc.; 5 l min(-1) flow rate). Particle mass was determined gravimetrically after 48 h of conditioning in a desiccator, in a Class 100 clean room at the temperature T = 20 degrees C and at about 50% constant relative humidity (RH). RESULTS AND DISCUSSION: Analysis of the PM10 data indicated a marked difference between season without heating--(summer; mean value 56 microg m(-3)) and heating season--(winter; mean value 96 microg m3); 62% of samples exceeded the level of 50 microg m(-3). The impact of meteorological factors on PM concentrations was not immediately apparent, but there was a significant negative correlation with the wind speed. CONCLUSIONS: The PM10 and PM2.5 mass concentrations in the Belgrade urban area had high average values (77 microg m(-3) and 61 microg m(-3)) in comparison with other European cities. The main sources of particulate matter were traffic emission, road dust resuspension, and individual heating emissions. When the air masses are coming from the SW direction, the contribution from the Obrenovac power plants is evident. During days of exceptionally severe pollution, in both summer and winter periods, high production of secondary aerosols occurred, as can be seen from an increase in PM2.5 in respect to PM10 mass concentration. RECOMMENDATION AND OUTLOOK: The results obtained gave us the first impression of the concentration level of particulate matter, with an aerodynamic diameter of less than 10 microm, in the Belgrade ambient air. Due to measured high PM mass concentrations, it is obvious that it would be very difficult to meet the EU standards (EEC 1999) by 2010. It is necessary to continue with PM10 and PM2.5 sampling; and after comprehensive analysis which includes the results of chemical and physical characterization of particles, we will be able to recommend effective control measures in order to improve air quality in Belgrade.  相似文献   

16.
17.
Tapered element oscillating microbalances (TEOMs) are used in the UK Automatic Monitoring Network for the continuous measurement of ambient airborne particles. Used TEOM filters from Swansea, Cardiff and Pembroke were examined under high-resolution field emission scanning electron microscopy (FESEM). Clusters of calcium sulphate crystals, gypsum (CaSO4·2H2O) and anhydrite (CaSO4) were abundant on spring and summer filters, and not present on autumn and winter filters. From textural considerations, the sulphates must have crystallised on the filter surfaces, either by dissolution and recrystallisation of CaSO4 collected as particles, or by direct precipitation from saline water collected on the filters; in much the same way as the formation of ‘desert roses’ by the evaporation of saline pore waters in desert sands. The proposed mechanism for the formation of these crystals has two important implications. Firstly, if the filters are episodically saturated with water, then on occasion the recorded masses will consist of both particles plus water, causing errors in the results of continuous monitoring; an important consideration for epidemiological studies based on TEOM data. Secondly, past toxicological experiments undertaken on TEOM-derived ‘PM10’ may have investigated material containing a significant component of in situ formed crystals, rather than the original PM10.  相似文献   

18.
There is growing scientific evidence linking early childhood exposure to environmental agents with asthma and other illnesses that may not appear until later in life. Unfortunately the direct measurement of personal exposures of children in the first year of life is not possible by existing methodologies. This study developed and evaluated a new methodology to better assess exposure of children to inhalable particles in the first year of life while involved in floor play in the home. We constructed the Pre-Toddler Inhalable Particulate Environmental Robotic (PIPER) sampler. Two series of measurements of inhalable particles were carried out. One collected filter samples of airborne inhalable particles and a second used a real-time total particle mass concentration monitor. Samples were collected for seven residential locations. Duplicate samples were collected with PIPER 20 cm above the floor and from an identical stationary monitor positioned at a height of 110 cm. The mean observed airborne inhalable particle concentrations measured by PIPER was 98.6 microg/ m3, whereas simultaneously collected stationary samples mean concentration was 49.8 microg/m3. The average observed ratio of PIPER samples to stationary samples was 2.4. A paired t test comparison of the two sampling methods indicated a statistically significant higher level of inhalable particle concentration measured by PIPER in comparison with the fixed sampler (P < 0.0001). Peak concentrations as measured by a real-time monitor were in excess of 3600 microg/m3. The results suggest that children playing on the floor are exposed to a higher concentration of total inhalable particles than previous methodologies estimate.  相似文献   

19.
Exposure of black carbon (BC) is associated with a variety of adverse health outcomes. A number of optical methods for estimating BC on Teflon filters have been adopted but most assume all light absorption is due to BC while other sources of colored particulate matter exist. Recently, a four-wavelength-optical reflectance measurement for distinguishing second hand cigarette smoke (SHS) from soot-BC was developed (Brook et al., 2010; Lawless et al., 2004). However, the method has not been validated for soot-BC nor SHS and little work has been done to look at the methodological issues of the optical reflectance measurements for samples that could have SHS, BC, and other colored particles. We refined this method using a lab-modified integrating sphere with absorption measured continuously from 350 nm to 1000 nm. Furthermore, we characterized the absorption spectrum of additional components of particulate matter (PM) on PM(2.5) filters including ammonium sulfate, hematite, goethite, and magnetite. Finally, we validate this method for BC by comparison to other standard methods. Use of synthesized data indicates that it is important to optimize the choice of wavelengths to minimize computational errors as additional components (more than 2) are added to the apportionment model of colored components. We found that substantial errors are introduced when using 4 wavelengths suggested by Lawless et al. to quantify four substances, while an optimized choice of wavelengths can reduce model-derived error from over 10% to less than 2%. For environmental samples, the method was sensitive for estimating airborne levels of BC and SHS, but not mass loadings of iron oxides and sulfate. Duplicate samples collected in NYC show high reproducibility (points consistent with a 1:1 line, R(2) = 0.95). BC data measured by this method were consistent with those measured by other optical methods, including Aethalometer and Smoke-stain Reflectometer (SSR); although the SSR looses sensitivity at filter loadings above 90 ng/mm(2). Furthermore, positive correlations (R(2) = 0.7) were observed between EC measured by NIOSH Method 5040 on quartz filters and BC measured in co-located Teflon filter samples collected from both heating and non-heating seasons. Overall, the validation data demonstrates the usefulness of this method to evaluate BC from archived Teflon filters while potentially providing additional component information.  相似文献   

20.
Tsai YI  Cheng MT 《Chemosphere》2004,54(8):1171-1181
Ambient PM10 aerosol samples were collected from Taiwan's Taichung metropolitan basin between October 1997 and January 1998, and their chemical characteristics studied. The average mass concentration of PM10 was 109.0 +/- 54.1 microg/m3. Carbonaceous materials, sulfate, nitrate, and ammonium were the most important contributors to the PM10 component. On average, 64% of the PM10 was made up of fine particles. During PM10 episodes, average wind speed was 0.7 m/s and relative humidity was high, 83% on average, probably giving rise to stagnation of air pollutants and their entrapment close to the surface. With relative humidity < 70%, NO3-, NH4+, SO4(2-), carbonaceous materials, and PM10 mass showed high correlation with maximum hourly average ozone (O3M). Variation in atmospheric humidity may affect the gas-to-particle interactions of S and N species. The most significant contribution to PM10 in the Taichung urban basin was from the photochemical formation of secondary aerosols and carbonaceous materials in the atmospheric environment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号