首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 281 毫秒
1.
PCDDs/PCDFs, dl-PCBs and HCB in the flue gas from coal fired CFB boilers   总被引:1,自引:0,他引:1  
The aim of the project was to measure the actual emissions of polychlorinated dibenzodioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), dioxin-like polychlorinated biphenyls (dl-PCBs) and hexachlorobenzene (HCB) from four selected power plants in Poland in order to update the national inventory of PCDDs/PCDFs emission. Relatively low PCDDs/PCDFs as well as dl-PCBs concentrations in flue gas obtained in measurements in this study for four different circulated fluidized bed (CFB) boilers indicate practical absence of any hazards caused by PCDDs/PCDFs emission from these units. The results of PCDDs/PCDFs determination obtained in this study indicate that hard coal combustion in large CFB in the four central heating plants (CHP) is not a significant source of PCDDs/PCDFs emission to the environment even if operated by co-firing of waste coal. PCDDs/PCDFs concentration in flue gases as well as emission factors were recorded in the range of 0.012-0.060ngI-TEQ/m(n)(3) and 7.51-46.4mugI-TEQ/TJ, respectively. Dl-PCBs concentration was practically below the LOQ=0.006ng WHO-PCB TEQ/m(n)(3) in all experiments. HCB concentration as well as emission factors were recorded in the range of 11.5-42.0ng/m(n)(3) and 6.19-26.7mg/TJ, respectively, where the highest value was obtained for co-firing of waste coal, however. Obtained in this work emission factors will be used for national emission inventory purposes instead of the factors proposed by Toolkit or taken from previous measurements. However, consideration should be given to the fact that the measurements in most cases are related to single installations. Therefore, the need for further development of national factors for the power generation industry in Poland is desired.  相似文献   

2.
Removal of PCDDs/DFs and dl-PCBs in MWI fly ash by heating under vacuum   总被引:1,自引:0,他引:1  
Temperature dependence of PCDD/DF and dioxin-like polychlorinated biphenyl (dl-PCB) concentrations in fly ash from a municipal waste incinerator (MWI) heated under vacuum has been investigated as a function of sample temperature ranging from T(s)=425 to 800 K to find out if PCDDs/DFs in fly ash evaporate and are trapped in a liquid nitrogen-cooled trap. The results show that more than 99.98% of PCDDs/DFs in TEQ is removed from fly ash by vacuum heat treatment at T(s)>650 K for 4 h. Almost no PCDDs/DFs were detected in the liquid nitrogen-cooled trap. Homologue distributions indicate that dechlorination/hydrogenation (DCH) reactions proceed in fly ash at T(s)>450 K. Arrhenius rate parameters for the DCH reactions have been determined for each homologue assuming that only DCH reactions occur. The fly ash heated under vacuum at 650 or 800 K was reheated at 573 K (300 degrees C) in a stream of dry or humid air to see how much PCDDs/DFs and dl-PCBs are regenerated. We have found that (1) PCDDs/DFs are regenerated in both 650 K and 800 K treated fly ash, whereas dl-PCBs are regenerated in 650 K treated fly ash, (2) formation of PCDFs predominates over that of PCDDs or dl-PCBs, and (3) less chlorinated homologues are abundant for PCDDs/DFs and dl-PCBs.  相似文献   

3.
Five fluidized bed incinerators combusting municipal solid waste were assessed for the impact of coplanar PCBs on total TEQ emission. In 17 stack measurements, the coplanar PCBs contributed on average less than 3% to total TEQ with a maximum contribution of 7.5% to total TEQ in one measurement. Differences in the design of the flue gas cooling section did not show an effect on the impact of coplanar PCBs on total TEQ. The effect of emission control devices on the impact of coplanar PCBs on the total TEQ was studied in more detail at one incinerator. The relative contribution of PCBs to total TEQ increased along the flue gas line. This was caused by a slightly higher removal efficiency for TEQ relevant PCDDs/PCDFs compared to coplanar PCBs by the bag filters and a higher destruction efficiency for PCDDs/PCDFs compared to PCBs by the SCR catalyst. Additionally, the removal efficiencies of the emission control devices (bag filters and catalyst) for other chlorinated aromatic compounds which have been proposed as TEQ indicator compounds (polychlorinated benzenes and polychlorinated phenols) were compared with those for PCDDs/PCDFs and coplanar PCBs. Removal efficiencies for polychlorinated benzenes or polychlorinated phenols considerably differed from those of PCDD/PCDF and coplanar PCBs. Implications for TEQ assessments using indicator compounds as proposed in the literature are discussed.  相似文献   

4.
Two artificial wastes (A and B) whose contents reflect regional differences in municipal solid waste composition, were used to investigate the thermal formation of polychlorinated dibenzo-p-dioxins (PCDDs), dibenzofurans (PCDFs), biphenyls (PCBs), and naphthalenes (PCNs) during incineration. Flue gas samples were simultaneously collected at three ports in the post-combustion zone corresponding to flue gas temperatures of 400, 300, and 200 °C. The combustion of Waste B, which had a higher chlorine and metal content than Waste A, produced greater levels of highly-chlorinated homologues, as demonstrated by a higher degree of chlorination. The total concentrations of PCDDs, PCDFs, PCBs, and PCNs formed in the combustion of both wastes increased as temperature decreased along the convector. There were no significant differences in total concentrations between Waste A and Waste B combustion at specific temperatures, with exception of PCDFs at 400 °C. Orthogonal Projections to Latent Structures Discriminant Analysis (OPLS-DA) modeling, used to evaluate the data for all compound groups, suggest that during flue gas quenching at temperatures of 400 °C low-chlorinated homologues are preferentially formed in the presence of copper, which is known to be a very active catalyst for this process. At 300 and 200 °C, the formation of highly-chlorinated homologues is favored.  相似文献   

5.
Nie Z  Zheng M  Liu W  Zhang B  Liu G  Su G  Lv P  Xiao K 《Chemosphere》2011,85(11):1707-1712
Magnesium production is considered to be one potential source of unintentional persistent organic pollutants (unintentional POPs). However, studies on the emissions of unintentional POPs from magnesium metallurgy are still lacking. Emissions of unintentional POPs, such as polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDD/Fs), dioxin-like polychlorinated biphenyls (dl-PCBs), polychlorinated naphthalenes (PCNs), hexachlorobenzene (HxCBz) and pentachlorobenzene (PeCBz) are covered under the Stockholm Convention. In this study, these emissions were investigated through a magnesium smelting process. Stack gas and fly ash samples from a typical magnesium plant in China were collected and analyzed to estimate the emissions of unintentional POPs from magnesium metallurgy. Emissions factors of 412 ng TEQ t−1 for PCDD/Fs, 18.6 ng TEQ t−1 for dl-PCBs, 3329 μg t−1 for PCNs, 820 μg t−1 for HxCBz, and 1326 μg t−1 for PeCBz were obtained in 2009. Annual emissions from magnesium metallurgy in China were estimated to be 0.46 g WHO-TEQ for PCDD/Fs and dl-PCBs, 1651 g for PCNs, 403 g for HxCBz and 653 g for PeCBz, respectively.  相似文献   

6.
A series of treatment experiments were carried out to evaluate the applicability of a high-temperature melting treatment (GeoMelt process) to the destruction of polychlorinated naphthalene (PCN) formulation. We started with 10-kg-scale experiments in which a small melting furnace was used and then scaled up to a 1-t-scale experiment in which a melting furnace that resembled an actual treatment system was used. These runs were evaluated whether destruction efficiency (DE) of total PCNs was more than 99.999 % and whether concentrations of PCNs and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/DFs) in vitrified materials, emission gas, and scrubber water were below the target levels. Because DE values and the target levels of PCNs and PCDDs/DFs in these runs were satisfactory, then we carried out a demonstrative experiment using the actual treatment system and confirmed destruction of PCNs. Based on good results of the demonstrative experiment, stock of PCN formulation was successfully treated continuously.  相似文献   

7.
Exposure to dioxins has raised much public concern recently. We determined the congeners' distribution of polychlorinated-dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (dl-PCBs) in the breast milk samples collected in Tokyo, Japan. Breast milk was taken from 240 mothers, 30 days after delivery in 1999 and 2000 in Tokyo, Japan. The actual concentration and TEQ concentration of PCDDs (14 congeners), PCDFs (15 congeners), and dl-PCBs (12 congeners), and each congener's contribution to the total TEQ level were calculated. Among all the samples, PCDDs accounted for 34.8%, PCDFs accounted for 23.5%, dl-PCBs accounted for 41.7%, which was also similar in the breast milk from the primiparae and secundiparae. The main contributors to the total TEQ with increasing percentages were 2,3,4,7,8-PeCDF, 1,2,3,7,8-PeCDD and 3,3',4,4',5-PCB (#126), and they accounted for more than 65% of the total TEQ. Detailed congener analysis in breast milk samples is effective to understand dioxin sources.  相似文献   

8.
Kim SC  Jeon SH  Jung IR  Kim KH  Kwon MH  Kim JH  Yi JH  Kim SJ  You JC  Jung DH 《Chemosphere》2001,43(4-7):701-707
This study was carried out to examine the formation and the emission status of polychlorinated dibenzo-p-dioxins/polychlorinated dibenzofurans (PCDDs/PCDFs) in the flue gases of commercial-scale municipal solid waste (MSW) incinerators, and thus to provide the engineering data for the reduction of PCDDs/PCDFs emitted from MSW incinerators. The formation concentrations of the PCDDs/PCDFs generated at the outlet of waste heat boilers (WHB) were in the range of 1.18-29.61 ng-TEQ/N m3 (average 5.75 ng-TEQ/N m3), while the emission concentrations at the stacks were in the range of 0.026-4.548 ng-TEQ/N m3 (average 0.924 ng-TEQ/N m3). Two major 2,3,7,8-substituted congeners were 2,3,4,7,8-PeCDF and 2,3,4,6,7,8-HxCDF, and their concentrations were up to 50% and 64% of total TEQ values at the outlet of WHB and the stack, respectively. From the results of multi-regression analysis, the formation concentration of PCDDs/PCDFs could be predicted as follows with the correlation factor of r2 = 0.962: PCDDs/PCDFs (ng-TEQ/N m3) = 3.036 (Cl) + 0.094 (T1) - 0.472 (Combustibles) + 0.059 (CO) - 0.039 (THC) - 3.366 (H) + 22.157, where T1 (degrees C) is the temperature at the outlet of the WHB. Cl, Combustibles and H are given as percentages and the others are in parts per million.  相似文献   

9.
Ham SY  Kim YJ  Lee DH 《Chemosphere》2008,70(9):1685-1693
To investigate the leaching characteristic of persistent organic pollutants (POPs), such as non-ortho and mono-ortho substituted chlorobiphebyls (dioxin-like PCBs), polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDDs/DFs), in leachate from municipal solid waste (MSW) landfill sites containing incineration residues, raw leachate samples were collected twice from 12 selected MSW landfill sites. The samples were divided into their liquid and solid phases using GF/B (pore size 1.0 microm), and the concentrations of POPs then determined. The concentrations of PCDDs/DFs ranged from 0.65 to 5.88 pg-TEQ/l (average 2.86 pg-TEQ/l), and those of dioxin-like PCBs from 0.05 to 0.32 pg-TEQ/l (average 0.18 pg-TEQ/l). The major congeners of leached PCDDs/DFs and dioxin-like PCBs in liquid and solid phases were OCDD (about 60%), 2,3',4,4',5-PeCBs (about 30%), and 2,3,4,4',5-PeCBs (about 54%). The relationship between landfill age and the leaching concentration of PCDDs/DFs, and effects of dissolved organic carbon (DOC) on the leaching of PCDDs/DFs are also discussed. Finally, a leaching prediction model of PCDDs/DFs from MSW landfills has been suggested using parameters, such as hydrophobic neutral organic carbons, total dissolved solid, and the ratio of non-biodegradable wastes in landfill sites.  相似文献   

10.
Control of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) in emissions and thermal residues from incinerators has been a cause of public concern for more than one decade. Recently, several studies showed that other persistent organic pollutants (POPs) such as coplanar polychlorinated biphenyls (co-PCBs) also have dioxin-like activity and are released from incinerators. Therefore, the present study was aimed at making a risk assessment about dioxin-like activity in extracts of thermal waste residues (e.g. combustion gas; fly ash, slag) from incineration and melting processes in Germany and Japan. For this purpose, polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs), coplanar polychlorinated biphenyls (co-PCBs), polychlorinated naphthalenes (PCNs) and polyaromatic hydrocarbons (PAHs) were analyzed by chemical analysis. Additionally, 2, 3, 7, 8-TCDD equivalents (EROD-TEQs) were determined by in vitro Micro-EROD bioassay using rat H4IIE hepatoma cells. EROD-TEQs could be correlated to I-TEQ values (from PCDD/Fs/co-PCBs) analyzed by chemical analysis resulting in a maximal sixfold higher estimate. Our study indicates minor influences of co-PCBs, PAHs and PCNs to the sum of dioxin-like toxicity in the extracts of thermal waste residues as determined here. Furthermore, we showed that the levels of dioxins and co-PCBs contained in slag from melting processes and bottom ashes from incineration processes were lower by 1-2 orders of magnitude than that in fly ash.  相似文献   

11.
This study determined the concentrations of organochlorine contaminants in common seafood in two Chinese coastal cities (Guangzhou and Zhoushan), and assessed the health risk due to the daily consumption of contaminated seafood. Twenty-six pooled samples, belonging to five food categories (fish, bivalves, shrimp, crab, and cephalopods), were purchased from local markets in Guangzhou and Zhoushan in 2003 and 2004. These samples were analyzed for total polychlorinated biphenyls (PCBs), non- and mono-ortho-PCBs (coplanar PCBs), polychlorinated naphthalenes (PCNs), and polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDDs/DFs). The concentrations of total PCBs and coplanar PCBs in fish samples were higher in Guangzhou than in Zhoushan, while the levels of PCNs and PCDDs/DFs were comparable between the two cities. The total daily intake values of dioxin-like compounds were 1.05 and 0.86pg WHO-TEQ/kg body weight in Guangzhou and Zhoushan, respectively. Hazard ratios of non-cancer risk in the two cities were all less than unity.  相似文献   

12.
Nine typical waste incinerating plants were investigated for polychlorinated naphthalene (PCN) contents in their stack gas. The incinerators investigated include those used to incinerate municipal solid, aviation, medical, and hazardous wastes including those encountered in cement kilns. PCNs were qualified and quantified by isotope dilution high resolution gas chromatography–high resolution mass spectrometry techniques. An unexpectedly high concentration of PCNs (13,000 ng?Nm?3) was found in the stack gas emitted from one waste incinerator. The PCN concentrations ranged from 97.6 to 874 ng?Nm?3 in the other waste incinerators. The PCN profiles were dominated by lower chlorinated homologues, with mono- to tetra-CNs being the main homologues present. Furthermore, the relationships between PCNs and other unintentional persistent organic pollutants involving polychlorinated dibenzo-p-dioxins and dibenzofurans, polychlorinated biphenyls, hexachlorobenzene, and pentachlorobenzene were examined to ascertain the closeness or otherwise of their formation mechanisms. A good correlation was observed between ΣPCN (tetra- to octa-CN) and ΣPCDF (tetra- to octa-CDF) concentrations suggesting that a close relationship may exist between their formation mechanisms. The results would provide an improved understanding of PCN emissions from waste incinerators.  相似文献   

13.
In this study, PCDDs/DFs and co-planar PCBs concentrations in flue gases from 17 crematories and in fly ashes and bottom ashes (mainly bone) from several crematories were measured to grasp the present state of PCDDs/DFs emissions from crematories. The effects of several factors were discussed to prevent PCDDs/DFs emissions from crematories. Total concentration (normalized by 12% O2) of PCDDs/DFs was ranged from 4.9 to 1200 ng/m3 N, and toxic equivalent concentration was ranged from 0.064 to 24 ng TEQ/m3 N. As the results obtained in this research, the following measures to reduce PCDDs/DFs emission are recommended for existing crematories: (1) keeping the temperature at 800 degrees C in main/secondary chambers during a whole cremation, and (2) lowering the temperature in the dust collector. For newly installed crematories, following measures to prevent PCDDs/DFs emission including the measures for existing ones are recommended: (1) connecting one secondary chamber to one main chamber, (2) installing the high efficiency dust collector and reducing dust concentration to less than 0.01 g/m3 N, and (3) installing the sampling point for monitoring of PCDDs/DFs.  相似文献   

14.
PCDDs/DFs emissions from crematories in Japan   总被引:1,自引:0,他引:1  
Concentrations of PCDDs and PCDFs in emission gases from 10 crematories were measured. The relationship between PCDDs/DFs and several factors such as structure, equipment and operational state of the crematory is discussed. Furthermore, emission of PCDDs/DFs from all crematories in Japan is estimated. The following results are obtained: (1) total concentration of PCDDs/DFs was 2.2-290 ng/N m3, whose TEQ concentration was 0.0099-6.5 ng TEQ/N m3; (2) total concentration of PCDFs was higher than that of PCDDs; (3) T4CDFs was the highest in the homologue pattern and 2,3,7,8-T4CDF was the highest in the isomer pattern; (4) emission of PCDDs/DFs was the largest in the first 20 min of cremation; (5) concentration of PCDDs/DFs was related to the existence of a secondary combustion chamber and a dust collector, and the ratio of the numbers of main and secondary combustion chambers; (6) total emission of PCDDs/DFs from crematories in Japan was estimated to be 8.9 g TEQ/yr.  相似文献   

15.
Emissions of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDDs/Fs) from incinerators and other stationary combustion sources are of environmental concern because of the toxicity of certain PCDD/F congeners. Measurement of trace levels of PCDDs/Fs in combustor emissions is not a trivial matter. Development of one or more simple, easy-to-measure, reliable indicators of stack PCDD/F concentrations not only would enable incinerator operators to economically optimize system performance with respect to PCDD/F emissions, but could also provide a potential technique for demonstrating compliance status on a more frequent basis. This paper focuses on one approach to empirically estimate PCDD/F emissions using easy-to-measure volatile organic C2 chlorinated alkene precursors coupled with flue gas cleaning parameters. Three data sets from pilot-scale incineration experiments were examined for correlations between C2 chlorinated alkenes and PCDDs/Fs. Each data set contained one or more C2 chloroalkenes that were able to account for a statistically significant fraction of the variance in PCDD/F emissions. Variations in the vinyl chloride concentrations were able to account for the variations in the PCDD/F concentrations strongly in two of the three data sets and weakly in one of the data sets.  相似文献   

16.
Wang LC  Lee WJ  Tsai PJ  Lee WS  Chang-Chien GP 《Chemosphere》2003,50(9):1123-1129
This study investigated four sinter plants, classified into two categories--with selective catalytic reduction (SCR) (S1, S2 and S3) and without SCR (S4) as its air pollution control device. Polychlorinated dibenzofurans (PCDFs) are dominant in the stack flue gases of sinter plants with and without SCR. The polychlorinated dibenzofurans/polychlorinated dibenzo-p-dioxins (PCDFs/PCDDs) ratio exceeds 1 extremely. The degree of chlorination of the sinter plant without SCR is towards hepta and hexa congeners while that of the sinter plant with SCR is towards penta and hexa congeners. PCDD/Fs are indeed decomposed (75.5% and 69% on ng and ng TEQ bases, respectively) and not only reduced in degree of chlorination. The overall concentration in the stack flue gas of sinter plants with SCR (7.97-14.1 ng/Nm(3); 0.995-2.06 ng TEQ/Nm(3)) is lower than that of the sinter plant without SCR (28.9 ng/Nm(3); 3.10 ng TEQ/Nm(3)). In Taiwan, based on the emission factors of 0.970 microg TEQ/ton-feedstock (sinter plants with SCR) and 3.13 microg TEQ/ton-feedstock (sinter plant without SCR), the annual PCDD/F emission of 44.7 g TEQ/year from sinter plants is 60 and 121 times higher than those from municipal solid waste incinerators (0.750 g TEQ/year) and MWIs (0.369 g TEQ/year). These results show that sinter plants have become the dominating PCDD/F emission source since tighter emission limits have been applied to incinerators.  相似文献   

17.
Combustion of brominated flame retardants and behavior of its byproducts   总被引:13,自引:0,他引:13  
The substance flow rate of PBDDs/DFs into flue gas and incineration residues from incineration of three types of waste samples containing brominated flame retardants were examined. The samples used consisted of PBDEs (a typical retardant), used TV casing materials (actual waste materials), and waste printed circuit boards. PBDDs/DFs concentrations in the experimental samples of PBDEs/PE, waste TV casing materials and printed circuit boards ranged between 3000 and 130,000 ng/g. These values are very high when compared to other investigations. The increase of chlorine concentration in input sample reduced the ratio of PBDDs/DFs in flue gas and raised the ratio of PCDDs/DFs. With adequate combustion control and flue gas treatment, the amount of PBDDs/DFs released from the incineration of resin containing brominated flame retardants was lower than the input amount. The presence of PBDDs/DFs in incineration residues dominated the total amount of dioxins released. When PBDDs/DFs, PCDDs/DFs and PXDDs/DFs were considered as a total, the total amount released was lower than the total amount input.  相似文献   

18.
Blood serum specimens from 81 non-occupationally exposed adults residing in four areas close to municipal and waste incinerators as well as metallurgical industry plant and 44 adult subjects coming from control area of Slovakia were analysed for polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), dioxin-like polychlorinated biphenyls (dl-PCBs) and polybrominated diphenylethers (PBDEs). The concentration of total WHO(98)TEQ PCDD/F/dl-PCBs in whole group of donors from areas where known sources causing dioxin contamination are present was significantly higher than in control group of donors (p<0.001). Correlation between the age of donors and PCDD/F and dl-PCB levels was confirmed (Spearman's r(PCDD/Fs)=0.543, r(dl-PCBs)=0.521, p<0.001). Furthermore, this study presents first results concerning the PBDE congeners in human serum of Slovak general population. The total concentration (congeners 28, 47, 99, 100, 153, 154, 183) in control group was approximately 1.5-times higher in comparison to that of residents coming from areas with supposed environmental pollution. The most abundant congeners in all samples were BDE-47 and BDE-153 with median values of 0.24 ng g(-1) lipid and 0.23ngg(-1) lipid, respectively. The positive association between PBDE values and age of donors was not found.  相似文献   

19.
In this paper the results of sampling for trace chlorinated organics at two municipal refuse incinerators in Ontario are presented. The information may be of Interest to individuals concerned with the assessment of PCDD/PCDF (polychlorinated dibenzo-p-dioxin/polychlorinated dibenzofuran) emissions from incineration of refuse and their impact on the energyfrom- waste program. PCDDs, PCDFs, PCBs (polychlorinated biphenyls), CBs (chlorobenzenes) and CPs (chlorophenols) were quantified in all process streams including refuse, ash and stack emissions. Manual sorting of refuse and collection of ash samples were carried out simultaneously with three 24-hour continuous stack sampling tests at each plant. The results suggested that the total output of PCDDs and PCDFs varied proportionately with their input at both incinerators. However, the input of PCDDs/PCDFs could not account for their total output. The chemistry of PCDDs/PCDFs in the input and output streams were different in that only heptachlorinated and octachlorinated species were present in significant quantities in the refuse while lower chlorinated species were predominant in stack emissions and ash streams. There was no correspondence between the Input of PCBs/CBs/CPs and the output of PCDDs/PCDFs. The output of PCDDs/PCDFs, however, varied Inversely with the total output of PCBs/CBs/CPs, suggesting that the latter compounds could have been partially responsible for the formation of PCDDs and PCDFs. The PCDF emissions were also affected by combustion conditions; they were higher in magnitude and consisted of predominantly tetrachlorinated and pentachlorinated species at the plant where the combustion temperatures were lower.  相似文献   

20.
Unintentionally produced persistent organic pollutants (UP-POPs) including polychlorinated dibenzo-p-dioxins, and dibenzofurans (PCDD/Fs), polychlorinated biphenyls (PCBs), and polychlorinated naphthalenes (PCNs) were characterized and quantified in stack gas and fly ash from the second ventilation systems in five typical converters in five different steelmaking plants. The 2378-substituted PCDD/Fs (2378-PCDD/Fs) and dioxin-like PCB (dl-PCBs) toxic equivalents (TEQs) were 1.84–10.3 pg WHO-TEQ Nm?3 in the stack gas and 5.59–87.6 pg WHO-TEQ g?1 in the fly ash, and the PCN TEQs were 0.06–0.56 pg TEQ Nm?3 in the stack gas and 0.03–0.08 pg TEQ g?1 in the fly ash. The concentrations of UP-POPs in the present study were generally lower than those in other metallurgical processes, such as electric arc furnaces, iron ore sintering, and secondary metallurgical processes. Adding scrap metal might increase UP-POP emissions, indicating that raw material composition was a key influence on emissions. HxCDF, HpCDF, OCDF, HpCDD, and OCDD were the dominant PCDD/Fs in the stack gas and fly ash. TeCB and PeCB were dominant in the stack gas, but HxCB provided more to the total PCB concentrations in the fly ash. The lower chlorinated PCNs were dominant in all of the samples. The 2378-PCDD/F, dl-PCB, and PCN emission factors in stack gases from the steelmaking converter processes (per ton of steel produced) were 1.88–2.89, 0.14–0.76, and 229–759 μg t?1, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号