首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 343 毫秒
1.
The production of cement in China is accompanied by various emissions, such as fine particulate matter, heavy metals, nitrogen oxides, sulfur oxides, carbon dioxide…. Moreover, cement kiln presents a potential health risk to its surroundings, linking to emissions of persistent organic pollutants (POPs), such as polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), in brief dioxins. Flue gas samples were collected from five typical cement kilns during twelve runs and were used to evaluate the levels and distribution of PCDD/Fs in the emissions from cement kilns. The PCDD/Fs concentrations (136 congeners) and I-TEQ values ranged from 2.3 to >40 ng/m3 and 9.3?~?90.8?×?10?3 ng I-TEQ/m3, respectively, which were lower than the emission standard in China (0.1 ng I-TEQ/m3). In weight units, the dominant congeners were OCDD, 1,2,3,4,6,7,8-HpCDF, and OCDF; 2,3,4,7,8-PeCDF is the largest contributor (36–66 %) to the total I-TEQ value of twelve runs. HxCDF and TCDF were the first two most abundant homologue groups (12–85 and 4–52 %), and the homologue concentration decreased with rising chlorine number for PCDDs. In addition, there was no marked difference in homologue profiles when solid wastes (refuse-derived fuel and municipal solid waste) and hazardous wastes (DDT and POPs) were combusted as supplemental fuels. The use of various supplemental fuels had no obvious effect on the fingerprint of PCDD/F homologues. Moreover, there was no significant difference in levels of PCDD/Fs emission due to the diversity of production capacity, which were consistent with reported previously. Air pollution control device had effect on the homologue profiles, and cement system with electrostatic precipitators (ESP) had more fractions of octachloro congeners to the total.  相似文献   

2.
The PCDD/F and PBDD/F pollution in the ambient atmosphere of Shanghai, China   总被引:11,自引:1,他引:10  
Li H  Feng J  Sheng G  Lü S  Fu J  Peng P  Man R 《Chemosphere》2008,70(4):576-583
Rapid economic growth in the last two decades in Shanghai has had a great adverse influence on its air quality. Therefore, the atmospheric pollutants of Shanghai have received much concern. In this study, concentrations of 2,3,7,8-substituted PCDD/Fs and PBDD/Fs congeners were measured in the ambient air of four districts in Shanghai. The mean atmospheric concentrations (TEQs) of total 2,3,7,8-PCDD/Fs and 2,3,7,8-PBDD/Fs were 8031 fg m(-3) (497.1 fg I-TEQ m(-3)) and 1358 fg m(-3) (304.1 fg I-TEQ m(-3)) for Jiading District, 5308 fg m(-3) (289.0 fg I-TEQ m(-3)) and 709 fg m(-3) (146.9 fg I-TEQ m(-3)) for Zhabei District, 4014 fg m(-3) (144.4 fg I-TEQ m(-3)) and 1239 fg m(-3) (256.9 fg I-TEQ m(-3)) for Pudong District, 3348 fg m(-3) (143.2 fg I-TEQ m(-3)) and 699 fg m(-3) (148.4 fg I-TEQ m(-3)) for Huangpu District, respectively. Our results showed that almost all the PCDD/Fs and PBDD/Fs congeners were partitioned into the particulate phase except the lower chlorinated or brominated ones. The logarithm of the gas/particle partitioning coefficient K(p) has good linear correlation with that of the sub-cooled vapor pressure p(L). Concentrations of PCDD/Fs and PBDD/Fs were both positively correlated to elemental carbon in all districts except Pudong District, suggesting elemental carbon could be a good indicator for dioxins' air pollution. It is intensively suggested that more detailed and deeper studies about PBDD/Fs should be carried out due to their relatively high atmospheric concentrations in Shanghai.  相似文献   

3.
Most polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in the atmosphere are bound to particles which are suspended in the atmosphere, and eventually settle on soil, vegetation, water bodies or other receptors in the environment. Monitoring atmospheric deposition fluxes (dry/wet) is important in tracing the environmental fate and behavior of PCDD/Fs. PCDD/F depositions were collected via an automated PCDD/F ambient sampler and traditional cylindrical vessels, respectively, from April 2007 to February 2008. The automated PCDD/F ambient sampler used in this study can prevent both re-suspension and photo degradation of the PCDD/Fs collected and effectively separates the PCDD/F samples into dry and wet contributions. The results indicated that the ambient PCDD/F concentrations collected using the PS-1 sampler ranged from 0.02 pg I-TEQ/m3 to 0.16 pg I-TEQ/m3 in Northern Taiwan. The results also indicated that the PCDD/F deposition flux collected using the automated PCDD/F sampler (17.5 pg I-TEQ/m2 d to 25.8 pg I-TEQ/m2 d) was significantly higher than that sampled with the cylindrical vessels (2.0 pg I-TEQ/m2 d to 9.9 pg I-TEQ/m2 d). The difference was attributed to the fact that part of the PCDD/F depositions collected using the traditional cylindrical vessels had undergone photo degradation and evaporation. In addition, the wet deposition flux of PCDD/Fs (39.4 pg I-TEQ/m2 rainy day to 228 pg I-TEQ/m2 rainy day) observed in this study was significantly higher than the dry deposition flux (12.3 pg I-TEQ/m2 sunny day to 16.7 pg I-TEQ/m2 sunny day). These results demonstrated that wet deposition is the major PCDD/F removal mechanism in the atmosphere.  相似文献   

4.
Municipal solid waste incinerators (MSWIs) have long been the major contributors of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) to ambient air in Taiwan. After stringent MSWI emission standards were introduced in 2001, the long-term continuous monitoring of flue gas and ambient air quality became necessary to ensure the effectiveness of the related control strategies. Three MSWIs and the surrounding ambient air were investigated in the current study for PCDD/F characteristics during 2006 to 2011. The average concentrations in the flue gas ranged from 0.008?~?0.0488 ng I-TEQ/Nm3, which is much less than the emission standard in Taiwan (0.1 ng I-TEQ/Nm3) (I-TEQ is the abbreviation of International Toxic Equivalent). This led to extremely low levels in the ambient air, 0.0255 pg I-TEQ/Nm3, much less than the levels seen in most urban areas around the world. Additionally, the results obtained using the Industrial Source Complex Short-Term Dispersion Model (ISCST3) indicate that the PCDD/F contributions from the three MSWIs to the ambient air were only in the range from 0.164?~?0.723 %. Principal component analysis (PCA) showed that the PCDD/Fs in the air samples had very similar characteristics to those from mobile sources. The results thus show that stringent regulations have been an effective control strategy, especially for urban areas, such as Taipei City.  相似文献   

5.
Polychlorinated dibenzo-p-dioxin and dibenzofuran (PCDD/PCDF) were overall measured and compared in ambient air, water, soils, and sediments along the upper reaches of the Haihe River of North China, so as to evaluate their concentrations, profiles, and to understand the processes of gas–particle partitioning and air–water/soil exchange. The following results were obtained: (1) The average concentrations (toxic equivalents, TEQs) of 2,3,7,8-PCDD/PCDF in air, water, sediment, and soil samples were 4,855 fg/m3, 9.5 pg/L, 99.2 pg/g dry weight (dw), and 56.4 pg/g (203 fg TEQ/m3, 0.46 pg TEQ/L, 2.2 pg TEQ/g dw, and 1.3 pg TEQ/g, respectively), respectively. (2) Although OCDF, 1,2,3,4,6,7,8-HpCDF, OCDD, and 1,2,3,4,6,7,8-HpCDD were the dominant congeners among four environmental sinks, obvious discrepancies of these congener and homologue patterns of PCDD/PCDF were observed still. (3) Significant linear correlations for PCDD/PCDF were observed between the gas–particle partition coefficient (K p) and the subcooled liquid vapor pressure (P L 0) and octanol–air partition coefficient (K oa). (4) Fugacity fraction values of air–water exchange indicated that most of PCDD/PCDF homologues were dominated by net volatilization from water into air. The low-chlorinated PCDD/PCDF (tetra- to hexa-) presented a strong net volatilization from the soil into air, while high-chlorinated PCDD/PCDF (hepta- to octa-) were mainly close to equilibrium for air–soil exchange.  相似文献   

6.
Polychlorinated biphenyls (PCBs) and polychlorinated dibenzodioxin and furan (PCDD/F) concentrations in the atmosphere were analysed using passive air samplers (PAS) close to the Rhine River between France and Germany. Collectors were placed in industrial, urban, rural and remote areas (Vosges Mountains) between March 2009 and August 2010, and the mean PCB concentrations (sum of 22 congeners) were 3.3, 3.9, 4.1 and 1.4 ng?PAS?1?day?1, respectively. Two events during the sampling period were observed in April 2009 and February–March 2010 with the highest PCB concentrations found in the industrial area (19.6 ng?PAS?1?day?1). PCDD/F level were measured during these periods, and the maximum concentration observed was from 37.5 fg?WHO?PAS?1?day?1  相似文献   

7.
Levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) were determined in fourteen ambient air samples collected in twelve cities of five provinces and one large municipality in China. The PCDD/F concentrations varied from 2.6 to 120 pg m−3 (or from 0.04 to 1.93 pg I-TEQ m−3). Generally, TCDF was the dominant homologue group and as a rule the homologue concentration of PCDF decreased with rising chlorine substitution number of PCDF. In all cases 2,3,4,7,8-PeCDF was the most important contributor to the I-TEQ value, accounting for 35–57% of the total I-TEQ value. Higher PCDD/F levels in ambient air were found during winter. The highest PCDD/F levels were found in Chengdu, Sichuan Province. In general, the PCDD/F levels in this study were in the same range as in other studies in China.  相似文献   

8.
Chang MB  Huang HC  Tsai SS  Chi KH  Chang-Chien GP 《Chemosphere》2006,62(11):1761-1773
Distribution of PCDD/F (polychlorinated dibenzo-p-dioxin and polychlorinated dibenzofuran) congeners at two electric arc furnaces (EAFs) in Taiwan is evaluated via intensive stack sampling and analysis. Two kinds of exhaust system in EAFs including stack system and shutter system are selected for measuring dioxin emissions. In addition, dioxin emissions during oxidation and reduction stages at EAF-A were characterized. Results indicate that the PCDD/F concentration of stack gas in EAF-A was 4.39 ng/N m3 while total Toxic Equivalent Quantity (TEQ) concentration was 0.35 ng I-TEQ/N m3. The PCDD/F concentration of stack gas in EAF-B was 2.20 ng/N m3 and the TEQ concentration was 0.14 ng I-TEQ/N m3. 1,2,3,4,6,7,8-HpCDF, OCDD and OCDF are the major contributors of the dioxin concentrations for two EAFs investigated and the percentage of PCDD/F in particulate phase increases as the chlorination level of the PCDD/F congener increases. The results obtained on gas/particulate partitioning of PCDD/Fs in flue gases prior to the APCD in EAFs indicate that more than 90% exists in particulate phase. In EAF-A, the PCDD/F concentration during oxidation stage is slightly higher than that measured during reduction stage, including the sampling points of CO converter outlet, prior to bag filter and stack. Majority of PCDD/Fs emitted from steel-making processes exists in particulate-phase (about 60–70%) at both EAFs investigated.  相似文献   

9.
Polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) were measured in bulk deposition at three Danish rural forest sites with a mutual maximum distance of 450 km. At one of the forest sites concentrations in the ambient atmosphere were sampled from a 12 m high tower. Sampling was carried out within a period of 3 years with sampling intervals of 1–2 months. Mean bulk deposition fluxes were 1 ng m−2 yr−1 I-TEQ and deviated less than 30% between the sites. Yearly average PCDD/F concentrations in the atmosphere were 24 fg m−3 I-TEQ with maximum values in the winter period. During winter months atmospheric concentrations of PCDD/F and oxidized sulphur compounds showed a positive correlation, furthermore seasonal bulk deposition showed correlation between PCDD/F and sulphate.  相似文献   

10.
Ten years measuring PCDDs/PCDFs in ambient air in Catalonia (Spain)   总被引:2,自引:0,他引:2  
This work summarizes the results of a ten year surveillance programme on PCDD/F in ambient air carried out in Catalonia (Spain). The study has been conducted by the Dioxin Laboratory of Spanish Council for Scientific Research (CSIC) in collaboration with the Environment Department of the Catalonian Government. 175 samples have been collected throughout Catalonia from 1994 to 2004. Different sampling locations classified as industrial, traffic, urban, suburban and rural sites have been monitored in order to find the most contaminated zones as well as the ones with expected background concentrations. The highest concentrations found in this study were determined at the industrial locations. Concentrations ranging from 5 to 1196 fg I-TEQ/m3, with a mean value of 140 fg I-TEQ/m3 and from 10 to 357 fg I-TEQ/m3, with a mean value of 72 fg I-TEQ/m3 were determined in industrial and traffic sampling points, respectively. In contrast, the lowest concentrations were found in rural stations, ranging from 5 to 45 fg I-TEQ/m3, with a mean value of 28 fg I-TEQ/m3. The PCDD/F concentration trend in Catalonian ambient air shown a clear drop of the median values occurred during the study sampling period. A decline of about 70% was observed from 1997-1998 to 2003-2004.  相似文献   

11.
PCDD/F contamination of the Baltic Sea has resulted in the European Union imposing restrictions on the marketing of several fish species. Atmospheric deposition is the major source of PCDD/Fs to the Baltic Sea, and hence there is a need to identify the source regions of the PCDD/Fs in ambient air over the Baltic Sea. A novel monitoring strategy was employed to address this question. During the winter of 2006–2007 air samples were collected in Aspvreten (southern Sweden) and Pallas (northern Finland). Short sampling times (24 h) were employed and only samples with stable air mass back trajectories were selected for analysis of the 2,3,7,8-substituted PCDD/F congeners. The range in the PCDD/F concentrations from 40 samples collected at Aspvreten was a factor of almost 50 (range 0.6–29 fg TEQ/m3). When the samples were grouped according to air mass origin into seven compass sectors, the variability was much lower (typically less than a factor of 3). This indicates that air mass origin was the primary source of the variability. The contribution of each sector to the PCDD/F contamination over the Baltic Sea during the winter half year of 2006/2007 was calculated from the average PCDD/F concentration for each sector and the frequency with which the air over the Baltic Sea came from that sector. Air masses originating from the south–southwest, south–southeast and east segments contributed 65% of the PCDDs and 75% of the PCDFs. Strong correlations were obtained between the concentrations of most of the PCDD/F congeners and the concentration of soot. These correlations can be used to predict the PCDD/F concentrations during the winter half year from inexpensive soot measurements.  相似文献   

12.
Chang MB  Chi KH  Chang-Chien GP 《Chemosphere》2004,55(11):1457-1467
Partitioning of PCDD/F congeners between gaseous and particulate phases and removal efficiencies of the air pollution control devices (APCDs) for PCDD/Fs at an existing municipal waste incinerator (MWI) in Taiwan are evaluated via stack sampling and analysis. The MWI investigated is equipped with electrostatic precipitators (EP), wet scrubbers (WS) and selective catalytic reduction system (SCR) as APCDs. The average PCDD/F concentration of stack gas is 1.49 ng/N m3, and the International Toxic Equivalent Quantity (I-TEQ) is 0.043 ng-I-TEQ/N m3. The EP increases PCDD/F concentration by 174.0% while the average removal efficiency of WS + SCR system for PCDD/Fs reaches 99.1%. In addition, the PCDF removal efficiency achieved with WS + SCR system (97.1–99.8%) is higher than that for PCDDs (96.5–99.3%). The results obtained on gas/particulate partitioning in flue gas indicate that the particulate-phase PCDD/Fs accounted for 65% at the inlet of EP, 20% at the outlet of EP and 50% at the stack, respectively, of the total PCDD/F concentrations. This study also indicates that as the chlorination level of PCDD/F congeners increases, the percentage of PCDD/Fs existing in gas phase decreases in all flue gas samples.  相似文献   

13.
The concentrations of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) were determined in plasma samples of 20 nonoccupationally exposed subjects living in the vicinity of a new hazardous waste incinerator (HWI), now under construction in Tarragona (Catalonia, Spain). The mean PCDD/F value was 27.0 pg I-TEQ/g lipid with a range from 14.8 to 48.9 pg I-TEQ/g lipid. All samples showed higher PCDD than PCDF levels. Although PCDD/F concentrations were higher in women (27.7 pg I-TEQ/g lipid) than in men (25.2 pg I-TEQ/g lipid), the difference was not statistically significant. While a significant correlation (r = 0.565, p < 0.01) between the age of the subjects and the levels of PCDD/F in plasma could be observed, no significant differences were found in relation to the specific residential area. The plasma concentrations of PCDD/F obtained in the current study are discussed and compared with the results of similar investigations reported in the last two years.  相似文献   

14.
Sampling and analysis of ambient dioxins in northern Taiwan   总被引:2,自引:0,他引:2  
Chang MB  Weng YM  Lee TY  Chen YW  Chang SH  Chi KH 《Chemosphere》2003,51(10):1103-1110
In this study, ambient air samples were taken concurrently in the vicinity area of a large-scale municipal waste incinerator (MWI) and the background area for measuring polychlorinated dibenzo-p-dioxins and furans (PCDD/Fs) concentrations from November 1999 through July 2000 in northern Taiwan. The results obtained from eighteen ambient air samples indicate that the mean PCDD/F concentration of seventeen 2,3,7,8-substituted congeners in wintertime (188–348 fg-I-TEQ/m3) is significantly higher than that measured in summertime (56–166 fg-I-TEQ/m3). In addition, the seasonal PCDD/F concentrations are compared with the ambient air quality data including CO, NO2, PM10 and TSP sampled from Taipei area to gain better insights. It indicates that the variation of ambient air PCDD/F concentrations is closely correlated with that of PM10 concentrations. Besides, the results indicate that the I-TEQ concentration of ambient air in sampling site B (directly downwind of the MWI) is of the highest while the sampling site A (upwind of MWI) is of the lowest among all sampling sites. This implies that existing MWI can be a significant emitter of PCDD/Fs in this area. Furthermore, the patterns of the PCDD/F congener distribution at all sampling sites (including the background site in Taoyuan) are quite similar. OCDD concentration is of the highest among seventeen PCDD/F congeners investigated and accounts for about 35% of the total concentration. As for the I-TEQ concentrations, 2,3,4,7,8-PeCDF is the most significant contributor, generally being responsible for 30–45% of the total I-TEQ values depending on the sampling sites and seasons.  相似文献   

15.
Atmospheric deposition of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) was investigated at four locations, namely at Yuancun, Wushan, Haizhu and Changban in Guangzhou City, Guangdong Province. The annual deposition fluxes of tetra- to octa-CDD/Fs (total PCDD/Fs) were found to range from 170 to 3000 (mean 1500) pg m−2 day−1, and the fluxes of total 2, 3, 7, 8-substituted PCDD/F congeners ranged from 2.1 to 41 (mean 20) pg WHO-TEQ m−2 day−1 at Wushan. The average deposition fluxes of total 2, 3, 7, 8-substituted PCDD/F congeners in rainy season were found to be 37, 27 and 28 pg WHO-TEQ m−2 day−1 at Yuancun, Haizhu and Changban, respectively, and the PCDD/F deposition fluxes behaved obviously higher in rainy season than in dry season. Results from regression analysis showed that number of rainy days, the amount of wet precipitation, PCDD/F concentrations in particles and organic carbon content played important roles in the variation of PCDD/F deposition fluxes. Monthly average temperatures change little over the year. Therefore, it only played a minor role in monthly variation of PCDD/F deposition fluxes. Particle deposition fluxes were generally not considered as the factor that could cause the differences in PCDD/F deposition fluxes between rainy and dry season, but were found to be related with PCDD/F deposition fluxes in rainy season or dry season. It was found that the profiles of PCDD/F homologs or congeners in the samples were the same either spatially or temporally, indicating that the PCDD/F emission sources were similar to one another. The similarities in PCDD/F homolog patterns and the differences in deposition fluxes between samples collected from heavy-traffic roadside and nearby residence house roof indicated that vehicle exhaust might be an important source for PCDD/F in Guangzhou. PCDD/F concentrations and profiles of PCDD/F homologs in atmospheric deposition were compared with those in both total suspended particles in air and soils, and conclusions indicated that atmospheric deposition possibly tended to remove lower-chlorinated DD/Fs from air and was one of sources for PCDD/Fs in soils.  相似文献   

16.
Particle-bound polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) and polychlorinated biphenyls (PCBs) were monitored at two sites in northern Greece for an eight-month period in 1999. PCDD/F concentrations were close to the lower end of reported values worldwide. Excepting a few cases, the PCDD/Fs homologue profile was stable. The gaseous PCDD/F fractions calculated were found to account for a small percentage of the total concentrations (<2% for OCDD/Fs and HpCDD/Fs, while 30-35% for TCDFs). Particle-bound PCBs were also found at low concentrations which, however, were higher at the urban site. Calculations of the dry deposition of particulate PCDD/ Fs and PCBs gave mean values of 0.52 and 0.59 pg I-TEQ/m2/day of PCDD/Fs, while 242 and 74 pg/m2/day of sigmaPCBs for the urban and the semirural areas respectively. An anticorrelation of PCDD/F concentrations with ambient temperature was derived particularly for the lower chlorinated congeners. A weak association with winds of western and southern origin was also observed. Factor analysis and literature source profiles were employed to identify possible emission sources. It was appeared that the PCDD/F compositional pattern of TSP is influenced by mixed sources the most prominent being uncontrolled fires and car exhausts.  相似文献   

17.
Particle-bound polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) in ambient air were monitored together with particulate matter less than 10 μm (PM10) at three sampling sites of the Andean city of Manizales, Colombia; during September 2009 and July 2010. PCDD/Fs ambient air emissions ranged from 1 fg WHO-TEQ m−3 to 52 fg WHO-TEQ m−3 in particulate fraction. The PM10 concentrations ranged from 23 μg m−3 to 54 μg m−3. Concentrations of PM10 and PCDD/Fs in ambient air observed for Manizales - a medium sized city with a population of 380 000 - were comparable to concentrations in larger cities. The highest concentrations of PCDD/Fs and PM10 found in this study were determined at the central zone of the city, characterized by public transportation density, where diesel as principal fuel is used. In addition, hypothetical gas fractions of PCDD/Fs were calculated from theoretical Kp data. Congener profiles of PCDD/Fs exhibited ratios associated with different combustion sources at the different sampling locations, ranging from steel recycling to gasoline and diesel engines. Taking into account particle and gas hypothetical fraction of PCDD/Fs, Manizales exhibited values of PCDD/Fs equivalent to rural and urban-industrial sites in the southeast and center of the city respectively. Poor correlation of PCDDs with PM10 (r = −0.55 and r = 0.52) suggests ambient air PCDDs were derived from various combustion sources. Stronger correlation was observed of PCDFs with PM10. Poor correlation between precipitation and reduced PM10 concentration in ambient air (r = −0.45) suggested low PM10 removal by rainfall.  相似文献   

18.
Abstract

This study investigates the characteristics of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in the ambient air of two municipal solid waste incinerators (MSWIs: GS and RW) and a coal-fired power plant (PW) in the Kaohsiung County (KC) area in Taiwan. The results show that the toxic equivalency (TEQ) concentration in the flue gas of GS and RW averaged 0.090 and 0.044 ng international toxic equivalents (I-TEQ)/N·m3, respectively. The TEQ concentration in the flue gas of PW averaged 0.050 ng I-TEQ/N·m3. All PCDD/Fs concentrations from the stack flue gas are lower than the Taiwan Environmental Protection Administration emission standard. Furthermore, the mean I-TEQ concentration in the ambient atmosphere ranged from approximately 0.019 to 0.165 pg I-TEQ/N·m3, much lower than the environmental quality standards for dioxins in Japan (0.6 pg TEQ/N·m3). This work classified all sampling sites into three clusters according to k-means cluster analysis. The result shows a probable direct correlation between the GS incinerator and site C. Although the concentration from the PW plant did not exceed the emission standard, it was much higher than that in Fernández-Martínez’s study. For proper environmental management of dioxins, establishing a complete emission inventory of PCDD/Fs is necessary. The government of Taiwan should particularly pay more attention to power plants to address the information shortage.  相似文献   

19.
The gas/particle partitioning of polychlorinated dibenzo-p-dioxins and furans (PCDD/Fs) was measured at three sites for a year in order to monitor the variation of PCDD/Fs levels and describe their partitioning. The air concentrations of PCDD/Fs ranged from 71 to 1161 fg I-TEQ/m3 and large changes in these levels did not correlate with seasonal changes during this study. Different homolog patterns were observed in the gas/particle phase. High chlorinated dioxin/furans dominated the particle phase while low chlorinated dioxin/furans dominated the gas phase. The high correlation coefficient between log [(PCDD/Fsvap)(TSP)/(PCDD/Fspat)] and 1/T was observed in lower chlorinated dioxin/furans unlike in OCDD/F. The slope of homolog ranged from −0.410 to −1.025 and that of 2,3,7,8-substituted isomers ranged from −0.379 to −0.772 in plots of the log partition coefficient (Kp) versus the log subcooled vapor pressure (PL°).The octanol/air partition coefficient (Koa)-based model of PCDD/Fs is more compatible with experimental data than those of the Junge–Pankow model that tends to overestimate results, even though both models include some level of uncertainty. However, both models can underestimate the particle phase of PCDD/Fs, especially when the ambient air temperature is extremely low in winter.  相似文献   

20.
Shin SK  Jin GZ  Kim WI  Kim BH  Hwang SM  Hong JP  Park JS 《Chemosphere》2011,83(10):1339-1344
Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) and dioxin-like polychlorinated biphenyls (DL-PCBs) were measured in ambient air samples collected from different parts of South Korea in 2008, and the measured levels were used for assessing the spatial and temporal distribution of atmospheric PCDDFs and DL-PCBs in South Korea. The average concentrations of atmospheric PCDD/Fs and DL-PCBs among the 37 sites were 28 fg I-TEQ m−3 (ND ∼ 617) and 1 fg WHO-TEQ m−3 (ND ∼ 0.016). Elevated atmospheric levels of PCDD/Fs and DL-PCBs observed at residential/industrial sites and in the north-west of Korea, indicated a potential contribution and impacts of anthropogenic sources of PCDD/Fs and DL-PCBs. These levels were similar or lower than those previously reported in other ambient air surveys. Average concentrations of PCDD/Fs showed small seasonal variations (ANOVA analysis, p = 0.144). The highest concentrations of PCDD/Fs were observed during winter, followed by spring, autumn and summer. Atmospheric PCDD/Fs and DL-PCBs in South Korea rapidly decreased during the last 10 years (1998-2008), demonstrating the efficiency of stricter regulations and the application of best available technologies/best environmental practices at emission sources. Comparison of the congener profiles and principal component analysis showed that current atmospheric PCDD/Fs are mostly influenced by industrial sources and PCBs from old commercial PCB uses. Nationwide POPs monitoring will continue and allows an effective evaluation of the implementation of the Stockholm Convention on POPs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号