首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 343 毫秒
1.
Distillery spent-wash has very high organic content (75,000 to 125,000 mg/L chemical-oxygen demand [COD]), color, and contains difficult-to-biodegrade organic compounds. For example, anaerobic treatment of the distillery spent-wash used in this study resulted in 60% COD reduction and low color removal. Subsequent aerobic treatment of the anaerobic effluent resulted in enhancement of COD removal to 66%. In this paper, the effect of ozonation on various properties of the anaerobically treated distillery effluent, including the effect on its subsequent aerobic biodegradation, was investigated. Ozonation of the anaerobically treated distillery effluent at various ozone doses resulted in the reduction of total-organic carbon (TOC), COD, COD/TOC ratio, absorbance, color, and increase in the biochemical-oxygen demand (BOD)/COD ratio of the effluent. Further, ozonation of the anaerobically treated distillery effluent at an ozone dose of 2.08 mg/mg initial TOC and subsequent aerobic biodegradation resulted in 87.4% COD removal, as compared to 66% removal when ozonation was not used.  相似文献   

2.
Laboratory-scale experiments were conducted in order to investigate the effect of ozone as pre-aerobic treatment and post-aerobic treatment for the treatment of the distillery wastewater. The degradation of the pollutants present in distillery spent wash was carried out by ozonation, aerobic biological degradation processes alone and by using the combinations of these two processes to investigate the synergism between the two modes of wastewater treatment and with the aim of reducing the overall treatment costs. Pollutant removal efficiency was followed by means of global parameters directly related to the concentration of organic compounds in those effluents: chemical oxygen demand (COD) and the color removal efficiency in terms of absorbance of the sample at 254 nm. Ozone was found to be effective in bringing down the COD (up to 27%) during the pretreatment step itself. In the combined process, pretreatment of the effluent led to enhanced rates of subsequent biological oxidation step, almost 2.5 times increase in the initial oxidation rate has been observed. Post-aerobic treatment with ozone led to further removal of COD along with the complete discoloration of the effluent. The integrated process (ozone-aerobic oxidation-ozone) achieved approximately 79% COD reduction along with discoloration of the effluent sample as compared to 34.9% COD reduction for non-ozonated sample, over a similar treatment period.  相似文献   

3.
This study is aimed at exploring strategies for mineralization of refractory compounds in distillery effluent by anaerobic biodegradation/ozonation/aerobic biodegradation. Treatment of distillery spent-wash used in this research by anaerobic-aerobic biodegradation resulted in overall COD removal of 70.8%. Ozonation of the anaerobically treated distillery spent-wash was carried out as-is (phase I experiments) and after pH reduction and removal of inorganic carbon (phase II experiments). Introduction of the ozonation step resulted in an increase in overall chemical oxygen demand (COD) removal, with the highest COD removals of greater than 95% obtained when an ozone dose of approximately 5.3 mg ozone absorbed/mg initial total organic carbon was used. The COD removal during phase II experiments was slightly superior compared with phase I experiments at similar ozone doses. Moreover, efficiency of ozone absorption from the gas phase into distillery spent-wash aliquots was considerably enhanced during phase II experiments.  相似文献   

4.
Fenton氧化-生化组合工艺处理染料中间体废水   总被引:9,自引:4,他引:9  
针对染料中间体废水具有COD高、BOD5/COD低和具有生物毒性的特性,采用Fenton氧化-水解酸化-好氧组合工艺进行染料中间体生产废水的处理试验,试验结果表明:废水经Fenton氧化及水解酸化工序后,废水的BOD5/COD值由0.03升高至0.48,经好氧生化工序处理后的出水COD和BOD5浓度分别达122.6 mg/L和54.6 mg/L,符合《污水综合排放标准》(GB8978-1996)二级标准,该组合工艺COD总去除率达94%.  相似文献   

5.
Treatment and detoxification of a sanitary landfill leachate   总被引:10,自引:0,他引:10  
The leachate from an old sanitary landfill (Gramacho Metropolitan Landfill, Rio de Janeiro) was characterized and submitted to coagulation and flocculation treatment followed by ozonation and ammonia stripping. The performance of the treatment was assessed by monitoring the removal of organic matter (COD and TOC), ammonium nitrogen and metals. Detoxification was assessed by determining acute toxicity, using the following organisms: Vibrio fisheri, Daphnia similis, Artemia salina and Brachydanio rerio. Membrane fractionation was employed to infer the range of molecular masses of the pollutants found in the effluent, as well as the toxicity associated to these fractions. Of the techniques under investigation, coagulation and flocculation followed by ammonia stripping were the most effective for toxicity and ammonium nitrogen removal. Membrane fractionation was effective for COD removal; however, acute toxicity was almost the same in all the fractionated samples. Ozonation was moderately effective for COD removal, but significant toxicity removal was only attained when high ozone doses were used.  相似文献   

6.
Advanced oxidation of a pulp mill bleaching wastewater.   总被引:8,自引:0,他引:8  
The degradation, by several advanced oxidation reactions, of a pulp mill ECF bleaching effluent, was studied. The initial biodegradability of the organic matter present in the effluent, estimated as the BOD5/COD, was low (0.3). When the effluent was submitted to ozonation and to five different advanced oxidation systems (O3/UV, O3/UV/ZnO, O3/UV/TiO2, O2/UV/ZnO, O2/UV/TiO2), the biodegradability increase significantly. After five minutes of reaction, the O3/UV system appears as the most efficient in to transform the organic matter to more biodegradable forms. A similar effect was observed when the effluent was submitted to an activated sludge treatment. The COD, TOC and toxicity reduction correlated well with the biodegradability enhancement after AOPs treatments.  相似文献   

7.
臭氧-曝气生物滤池深度处理印染制革园区废水   总被引:3,自引:0,他引:3  
针对浙江省某印染制革园区污水处理厂二级生化出水,开展了处理规模36~120 t/d的臭氧-曝气生物滤池中试研究,对臭氧预处理进行优化,考察了臭氧预处理优化后与不同填料BAF组合对污染物的去除情况。结果表明,当臭氧预处理条件为投加量25 mg/L,三点投加且投加比为6:3:1,臭氧接触时间为42 min时,处理效果较好且最经济;在此臭氧预处理条件下,臭氧-活性炭BAF的出水COD能稳定在50 mg/L,色度稳定在5度,满足《城镇污水厂污染物排放标准》(GB 18918-2002)中的一级B排放要求;臭氧-混合填料BAF的出水COD和色度也能基本达到一级B排放要求;而臭氧-陶粒BAF出水COD和色度都未能达到一级B排放要求。  相似文献   

8.
城市污水厂二级处理出水深度处理组合工艺研究   总被引:2,自引:0,他引:2  
为了研究臭氧-曝气生物滤池二级处理出水深度处理组合工艺的处理效果,采用臭氧-曝气生物滤池(biological aerated filter, BAF)组合工艺对城市污水处理厂二级生化处理出水进行深度处理。结果表明,组合工艺对造成水中色度的主要物质腐植酸和富里酸类有机物和嗅味物质中的二甲基三硫和二甲基异莰醇(MIB)能够进行有效去除。臭氧氧化能够显著提高后续BAF单元对CODMn的去除。在进水CODMn6~8 mg/L、色度为25~30度、浊度约为8 NTU的条件下,当臭氧投加量为5~6 mg/L、BAF的水力停留时间为1~1.5 h时,出水CODMn< 5 mg/L、色度<5度、浊度<1 NTU,出水水质可满足生产工艺对回用水的水质要求。  相似文献   

9.
The efficiency of several lab scale treatments (aerobic, anaerobic and ozone or combination of these) was evaluated using two packaging board mill whitewaters. The effect of the different treatments on the elimination of the organic load, the chemical oxygen demand (COD) and the toxicity was tested as well as the relationship between these parameters. Biocides, phenolic compounds, surfactants, plasticiziers and wood extractives were identified in untreated and treated whitewaters by liquid chromatography coupled with mass spectrometry (LC-MS) or gas chromatography coupled with mass spectrometry (GC-MS). A strong dependency on the water type and treatment efficiency was observed, being the combination of anaerobic and aerobic treatments the best option to reduce the organic contaminants in these waters, although in some cases, the toxicity did not decrease. However, ozone as post-treatment permitted a further reduction of organic compounds, toxicity and COD.  相似文献   

10.
Ozonation characteristics of synthetic Procaine Penicillin G (PPG) formulation effluent were investigated in a semi-batch ozone reactor at different pH (3, 7 and 12), ozone feed rates (600-2600 mg h-1) and COD values (200-600 mg l-1). Ozonation of aqueous PPG effluent resulted in 37 (82)% COD removal after 60 (120) min ozonation when the reaction pH was kept constant at pH=7.900 mg l-1 (corresponding to 50% of the total introduced) ozone was absorbed during a reaction period of 1 h. The effects of increasing the applied ozone dose and the initial COD on the COD abatement rates of PPG effluent were also studied. Results have indicated that increasing the ozone dose and decreasing the COD content both have positive effects on COD removal rates. The significant contribution of the free radical (.OH) reaction pathway to PPG ozonation could be traced using tert-butyl alcohol as the .OH probe compound at varying concentrations. The bimolecular reaction rate constants for the direct reaction of PPG with ozone were found as 152 and 2404 M-1 h-1 at pH=3 and 7, respectively, using the gas phase ozone partial pressures determined from of the outlet gas stream analysis. It could be demonstrated that ozone decomposition to free radicals being triggered by increasing the pH from 3 to 7 is essential for the rate enhancement of PPG effluent ozonation.  相似文献   

11.
The coking wastewater generally comprises highly concentrated, recalcitrant, and toxic organic pollutants, so its treatment has been of great importance to prevent living beings and their environment from these hazardous contaminations. The treatment of pretreated coking wastewater by flocculation-coagulation, alkali out, air stripping, and three-dimensional (3-D) electrocatalytic oxidation was performed (gap between the used β-PbO2/Ti anode and titanium cathode, 12 mm; mass ratio of Cu-Mn/granular activated carbon (GAC) to effluent, 1:4; cell voltage, 7 V). The results showed that the pH adjusting from 3.7 to 6.1 was necessary for coagulants; alkali out played an important role because it brought up precipitation containing higher fatty acids as well as other contaminants to decrease the chemical oxygen demand (COD) in the effluent, and it had also forced the reduction of ammonia nitrogen (NH3-N) by incorporating with air stripping; for 3-D electrocatalytic oxidation with a bleaching liquid assisting, the initial pH 8.5 of effluent was suitable for Cu-Mn/GAC; moreover, it was considered that its Cu component was dedicated to the decrease of COD and NH3-N, while the Mn component specialized in the decay of NH3-N. The residual COD and NH3-N values in the final effluent with pH 6.5 were 95.8 and 8.8 mg/L, respectively, demonstrating that the whole processes applied were feasible and low in cost.  相似文献   

12.
The efficacy of ozonation and of photocatalysis processing in the treatment of pulp mill ECF (elementary chlorine free) bleaching and textile effluents was evaluated by determining total organic carbon reduction (TOC) and the toxicity. The chronic toxicity of the effluents was evaluated by the ability to inhibit the growth of algae Selenastrum capricornutum. Cultured hamster V79 fibroblasts were used to assess the cytotoxicity of effluents submitted to different detoxification processes. Two endpoints were measured in V79 cells: 3-(4,5-dimethylthiazole-2-yl)-2,5-biphenyl tetrazolium bromide (MTT) reduction and neutral red uptake (NRU). Both treatment processes were able to reduce the TOC, although ozonization was less effective for pulp mill ECF bleaching. The pulp mill ECF bleaching and textile effluents reduced the growth of S. capricornutum by 39% and 27%, respectively. However, at the highest concentration tested, the textile effluents treated by photochemical process for 60 min showed increased cytotoxicity in V79 cells compared to the untreated effluent when assessed by the NRU and MTT reduction assays (increases of 30% and 40%, respectively). Pulp mill ECF bleaching effluent treated by ozonization had a similar cytotoxicity to that of untreated effluent in the NRU assay. In contrast, the MTT reduction assay indicated that effluents treated with ozone were around 20% more cytotoxic than untreated effluents. These results show that cultured fibroblasts may be useful for studying cellular responses to pollutants and may be included in tests to monitor the efficiency of effluent detoxification processes.  相似文献   

13.
以某地表水为原水(TOC为5.3mg/L),研究了氯、氯胺和臭氧3种消毒剂对可同化有机碳(AOC)的影响。结果表明,投加1mg/L氯氧化30min就会使AOC升高近3倍。投加3种剂量(1、2、3mg/L)的氯胺,氧化30min时AOC增加不到1倍;氧化24h时AOC浓度均比30min时的高,这说明氯胺的作用机理与氯不同。投加臭氧2.0mg/L氧化30min时可使AOC增加2.4倍;当臭氧质量浓度大于2.0mg/L时,AOC开始下降,这说明一部分中间产物进一步被氧化成了二氧化碳和水。  相似文献   

14.
采用臭氧氧化法对生活垃圾焚烧厂沥滤液经生化处理后的废水(称沥滤液生化处理水)进行深度处理。实验结果表明,COD降解速率随废水pH的提高明显增加,其中pH=10.5时的COD降解速率常数约为pH=4时的5.8倍。在臭氧投量为52.92 mg/min、pH=10.5的条件下反应70 min后,UV254和COD去除率分别达到84.7%和59.3%。向反应体系投加叔丁醇后COD去除率下降了约15%,由羟自由基氧化去除的COD占总COD去除量的26.7%。毒性实验结果表明,沥滤液生化处理水的96 h-EC50为38%,经臭氧氧化进一步处理后出水的96 h-EC50为77%,表明经臭氧深度处理后沥滤液生化处理水的毒性明显降低。  相似文献   

15.
臭氧预处理—厌氧消化工艺促进剩余污泥减量化的研究   总被引:1,自引:0,他引:1  
主要研究了臭氧氧化对剩余污泥的破解效果及污泥厌氧消化效率的影响.结果表明,随着臭氧投加量的增加,悬浮物(SS)、可挥发性悬浮物(VSS)逐步减少,而剩余污泥上清液中的溶解性COD(SCOD)、总有机碳(TOC)、蛋白质和多糖则明显增加.经臭氧预处理(臭氧投加量为0.050 g(以每克SS计))后,剩余污泥中温(35℃)厌氧消化效率明显提高,经65d稳定运行后,总挥发性固体(TVS)去除率为67.58%,与未经臭氧预处理的剩余污泥相比提高50.61%;甲烷平均产率为0.303 L(以每克TVS计),与未经臭氧预处理的剩余污泥相比提高54.59%.可见,臭氧预处理能有效促进污泥厌氧消化,从而达到污泥减量的目的.  相似文献   

16.
The main objective of this study was to investigate the feasibility of coagulation as a post-treatment method of anaerobically treated primary municipal wastewater. Both mesophilic and ambient (20 degrees C) temperature conditions were investigated in a laboratory-scale upflow anaerobic sludge bed (UASB) reactor. In addition, optimization of the coagulant, both in terms of type and dose, was performed. Finally, phosphorus removal by means of aluminum and iron coagulation and phosphorus and ammonia nitrogen removal by means of struvite precipitation were studied. Anaerobic treatment of primary effluent at low hydraulic retention times (less than 15 hours) resulted in mean chemical oxygen demand (COD) removals ranging from 50 to 70%, while, based on the filtered treated effluent, the mean removals increased to 65 to 80%. Alum coagulation of the UASB effluent gave suspended solids removals ranging from approximately 35 to 65%. Turbidity removal reached up to 80%. Remaining COD values after coagulation and settling were below 100 mg/L, while remaining total organic carbon (TOC) levels were below 50 mg/L. Filterable COD levels were generally below 60 mg/L, while filterable TOC levels were below 40 mg/L. All coagulants tested, including prepolymerized aluminum and iron coagulants, demonstrated similar efficiency compared with alum for the removal of suspended solids, COD, and TOC. Regarding struvite precipitation, optimal conditions for phosphorus and nitrogen removal were pH 10 and molar ratio of magnesium: ammonia-nitrogen: phosphate-phosphorus close to the stoichiometric ratio (1:1:1). During struvite precipitation, removal of suspended solids reached 40%, while turbidity removal reached values up to 80%. The removal of COD was approximately 30 to 35%; yet, when removal of organic matter was based on the treated filterable COD, the removal increased to approximately 65%. In addition, nitrogen was removed by approximately 70%, while phosphorus removal ranged between approximately 30 and 45% on the basis of the initial phosphorus concentration. Finally, size fractionation of the organic matter (COD) showed that the various treatment methods were capable of removing different fractions of the organic matter.  相似文献   

17.
采用内循环好氧生物流化床对中低浓度糖业废水进行生物降解,当进水COD、NH3-N浓度分别为400~600mg/L和7~11 mg/L时,其相应去除率达到80%~90%和70%~80%,处理效果良好;COD容积负荷可达到5.1 kg COD/(m3·d),反应器具有较强的抗负荷冲击能力.采用臭氧氧化工艺对COD浓度为28...  相似文献   

18.
This study examines the feasibility of coupling a Catalytic Wet Air Oxidation (CWAO), with activated carbon (AC) as catalyst, and an aerobic biological treatment to treat a high-strength o-cresol wastewater. Two goals are pursued: (a) To determine the effect of the main AC/CWAO intermediates on the activated sludge of a municipal WasteWater Treatment Plant (WWTP) and (b) To demonstrate the feasibility of coupling the AC/CWAO effluent as a part of the influent of a municipal WWTP. In a previous study, a high-strength o-cresol wastewater was treated by AC/CWAO aiming to establish the distribution of intermediates and the biodegradability enhancement. In this work, the biodegradability, toxicity and inhibition of the most relevant intermediates detected in the AC/CWAO effluent were determined by respirometry. Also, the results of a pilot scale municipal WWTP study for an integrated AC/CWAO-aerobic biological treatment of this effluent are presented. The biodegradation parameters (i.e. maximum oxygen uptake rate and oxygen consumption) of main AC/CWAO intermediates allowed the classification of the intermediates into readily biodegradable, inert or toxic/inhibitory compounds. This detailed study, allowed to understand the biodegradability enhancement exhibited by an AC/CWAO effluent and to achieve a successful strategy for coupling the AC/CWAO step with an aerobic biological treatment for a high-strength o-cresol wastewater. Using 30%, as COD, of AC/CWAO effluent in the inlet to the pilot scale WWTP, the integrated AC/CWAO-biological treatment achieved a 98% of total COD removal and, particularly, a 91% of AC/CWAO effluent COD removal without any undesirable effect on the biomass.  相似文献   

19.
The photo-Fenton reaction effect on the biodegradability improvement of 100 mg/L solution of 2,4-dichlorophenol (DCP) has been investigated. Biochemical oxygen demand (BOD) at 5 and 21 days, BODn/ chemical oxygen demand (COD) and BODn/total organic carbon (TOC) ratios, average oxidation state, and inhibition on activated sludge were monitored. For 50 mg/L hydrogen peroxide and 10 mg/L iron(II) initial concentrations and 40 minutes of reaction time in the photo-Fenton process, the biodegradability of the pretreated solution, measured as BOD5/COD ratio, was improved from 0 for the original DCP solution up to 0.18 (BOD21/COD = 0.24). At that point, all DCP was eliminated from the solution. To study the effect of the pretreatment step, the biological oxidation of pretreated solutions was tested in two semicontinuous stirred tank reactors, one operated with activated sludge and one with biomass acclimated to phenol. Results showed that more than 80% TOC removal could be obtained by codigestion of the pretreated solution with municipal wastewater. Total organic carbon removals of approximately 60% were also obtained when the sole carbon source for the aerobic reactors was the pretreated solution. The hydraulic retention times used in the bioreactors were of the same order of magnitude as those used at domestic wastewater treatment plants (i.e., between 12 and 24 hours). Kinetic studies based on pseudo-first-order kinetics have also been carried out. Constants were found to be in range 0.67 to 1.7 L x g total volatiles suspended solids(-1) x h(-1).  相似文献   

20.
The treatment of an effluent from the production of trifluraline was studied using a 1-L, semi-batch, tank-stirred glass reactor for performing three different advanced oxidation processes (photoperoxidation, Fenton, photo-Fenton). A commercial, medium-pressure mercury lamp was used for sample irradiation. The degradation was monitored by measurements of absorptiometric color reduction, UV-visible absorption spectra, and chemical oxygen demand (COD). The obtained results showed that the photo-Fenton process was the most effective treatment for the trifluraline effluent.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号