首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 58 毫秒
1.
衍生化气相色谱-质谱联用法测定土壤中多种酚类化合物   总被引:2,自引:0,他引:2  
采用衍生化气相色谱-质谱联用法测定土壤中17种酚类化合物,通过试验优化方法参数,使17种酚类化合物在0.400 mg/L~10.0 mg/L范围内线性良好。当取样量为10.0 g时,方法检出限在0.01 mg/kg~0.04 mg/kg之间,实际土壤样品的加标回收率为60.4%~104%,6次平行测定结果的RSD不超过12.5%。  相似文献   

2.
通过将动态吹扫捕集气相色谱-质谱联用技术在线化,实现了全自动在线测定地表水中的54种挥发性有机物(VOCs),并能对其他VOCs进行定性半定量监测。54种VOCs的方法检出限为0.05~0.74μg/L,在0~10μg/L范围内线性良好;加标回收率为69.6%~107.2%;除1,2,4-三氯苯等5种VOCs外,其余49种VOCs的测定标准偏差均10%。该方法检出限、线性、准确度和精密度都能满足水质自动监测的需要。  相似文献   

3.
采用液液萃取-气相色谱/质谱联用法测定饮用水源水中19种苯胺类化合物,选择DB-5MS色谱柱,讨论了pH值对回收率的影响.方法在0.500 mg/L~5.00 mg/L范围内线性良好,19种苯胺类化合物的检出限为0.016μg/L~0.067 μg/L,标准溶液平行测定的RSD为1.2% -13.2%,实际样品加标回收...  相似文献   

4.
建立了顶空-气相色谱-质谱联用测定水中丁基黄原酸的方法。丁基黄原酸在酸性条件下分解成易挥发的二硫化碳,可用顶空-气相色谱分离、质谱定量测定。与传统的分光光度法相比,该法简便、快捷,在0.010~1.00 mg/L范围内线性良好,准确度高,加标回收率为95.1%~100.6%,精密度好,相对标准偏差为3.1%~6.5%,方法检出限为0.002 mg/L,适用于水中丁基黄原酸的监测。  相似文献   

5.
采用气相色谱-质谱联用法测定水中9种卤代乙酸类化合物,通过优化试验条件,使方法在5.00μg/L~200μg/L范围内线性良好。当取样量为40 m L时,方法检出限在0.7μg/L~1.0μg/L之间,3种实际水样的加标回收率为81.2%~98.0%,6次平行测定结果的RSD≤12%。  相似文献   

6.
气相色谱/质谱联用法测定环境空气中恶臭类硫化物   总被引:8,自引:0,他引:8       下载免费PDF全文
采用冷阱预浓缩-气相色谱/质谱联用法测定环境空气中硫化氢、甲硫醇、甲硫醚、二硫化碳、二甲二硫、噻吩等6种硫化物,讨论了采样容器材质的影响。方法线性良好,6种硫化物的检出限为1.0μg/m3~5.0μg/m3,混合标准气平行测定的RSD≤8.1%,加标回收率为93.5%~97.3%。  相似文献   

7.
建立了吹扫捕集-气相色谱-质谱联用测定水中丁基黄原酸的方法.丁基黄原酸在酸性条件下分解成易挥发的二硫化碳,经吹扫捕集富集后用气相色谱分离质谱定量测定.与传统的分光光度法相比,更简便快捷,在0.25~10.0μg/L范围内线性良好,准确度高,添加回收率为98.3%~105%,精密度好,相对标准偏差为5.92% ~ 10.7%,方法检出限为0.07μg/L.与顶空法相比,灵敏度更高.  相似文献   

8.
采用固相微萃取与气相色谱-质谱联用测定饮用水中甲基叔丁基醚(MTBE),研究了萃取头涂层材料、萃取温度、盐浓度、萃取时间和溶液的pH值等操作条件对分析方法的影响.该方法分析MTBE的线性范围0.01-10μg/L,检出限0.66ng/L.0.01μg/L的MTBE水样五组平行测定实验中,相对标准偏差为4.8%.用所建立的方法测得大兴某地下水中MTBE的含量0.8μg/L,加标回收率达到90%.  相似文献   

9.
气相色谱/质谱联用法测定水中甲萘威   总被引:3,自引:0,他引:3       下载免费PDF全文
采用二氯甲烷萃取、气相色谱/质谱联用选择离子方式测定水中甲萘威,优化了试验条件。方法在0.010 mg/L~0.400 mg/L范围内线性良好,检出限为0.001 mg/L,3种浓度的添加试验平均回收率为81.3%~93.3%,RSD为3.3%~12.2%。  相似文献   

10.
采用吹扫捕集-气相色谱/质谱联用法测定地表水中氯丁二烯。当进样体积为20 mL时,方法在0.100μg/L~50.0μg/L范围内线性良好,检出限为0.05μg/L,标准溶液平行测定的RSD≤3.7%,地表水样加标回收率为91.0%~101%,方法可用于地表水中卤代烃、苯系物等其他21种挥发性有机物的同时测定。  相似文献   

11.
通过优化顶空条件(氯化钠加入量、顶空平衡温度、顶空平衡时间),对采用顶空-气相色谱-质谱联用法测定地下水中55种挥发性有机物的方法进行探究.结果表明:该方法检出限为0.24~2.30μg/L,相对标准偏差为0.76% ~13.2%,实际样品加标回收率为82.7% ~119%.该方法具有较高的灵敏度、精密度和准确度,操作...  相似文献   

12.
建立了吹扫捕集-气相色谱/质谱法(GC-MS)测定饮用水源地水中乙醛的方法。方法的检出限为0.5μg/L,相对标准偏差为3.9%~4.6%,加标回收率为92.5%~97.8%。该方法操作简单,灵敏度高,适用于水源水中乙醛的测定。  相似文献   

13.
气相色谱-串联质谱法测定水中己烯雌酚残留   总被引:2,自引:0,他引:2  
采用乙酸乙酯提取水样中己烯雌酚残留,经BSTFA/TMCS衍生化后,用GC-MS/MS测定,通过优化试验条件,使该方法在0.05 mg/L~1.00 mg/L范围内线性良好,方法检出限为146 ng/L。实际水样2个质量浓度水平的加标回收率为90.8%和91.9%,5次测定结果的RSD分别为2.2%和2.1%。  相似文献   

14.
We have aimed at characterizing top soil samples taken in-situ from five different locations of the unregulated dumping site in Eskişehir/Turkey for a period of six months. The study is the first attempt in the city and in Turkey, regarding particularly the SPME (Solid Phase Microextraction Technique) analysis method utilized. A comprehensive research has been conducted to produce critical soil data to be used for indicating current risks as well as the urgency of rehabilitating the site and establishing a sanitary landfill in the site. Conventional physicochemical analytical methods and SPME technique were used to analyze the samples. Physicochemical analyses were performed for determining the pH, total dried matter, volatile matter, total nitrogen, phosphorus, macro elements and heavy metals. Meteorological data were also recorded for the same period. SPSS.10.0 statistical program was used to determine the correlation between meteorological data and physicochemical analysis results. Mean values were used in the correlation analyses. These data indicated that the air temperature and precipitation have significant effects on soil characteristics. SPME, coupled with GC/MS, was used to identify eighty six volatile and semi-volatile organic compounds contained in soil samples. The samples were extracted by headspace SPME with heating (δHS-SPME). SPME analyses were conducted using a commercially available polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber having a film thickness of 65 μm (Supelco) as a capture medium. The experimentally optimized headspace sampling conditions were arranged (15 min. at 50˚C) before a 30 min. sampling period.  相似文献   

15.
针对室内空气挥发性有机物测定方法的不足,本文采用预冷浓缩系统和气相色谱,质谱联用。建立了测定室内空气中39种挥发性有机物的分析方法,该方法采用苏码罐采样,经液氮预冷冻浓缩后,用心城由检测。该方法灵敏度高,操作简便、重现性好、准确度高,适用于室内空气中挥发性有机物的测定。  相似文献   

16.
采用动态顶空气相色谱FID法测定水中乙醛、丙酮、甲醇、丙烯醛、丙烯腈、乙腈、吡啶等7种极性水溶性有机物,通过优化动态顶空条件,使该方法在0.157mg/L~7.92mg!L之间线性良好。方法检出限在0.008mg/L~0.048mg/L之间,空白水样的加标回收率为103%~111%,RSD为5.4%~8.7%。用该方法测定某制药企业排口污水和地表水,只有污水中甲醇、乙腈、吡啶有响应值。  相似文献   

17.
水中的VOCs经吹扫富集、解吸后,用HP-VOC色谱柱分离,采用全扫描和选择离子监测模式分析,内标法定量。最佳富集条件为:吹扫流速为40 m L/min,吹扫温度为40℃,吹扫时间为15 min,解吸温度为200℃,解吸时间为2 min。该法27种VOCs在一定的质量浓度范围内与其峰面积呈线性关系,相关系数r0.995,检出限为0.02~1.18μg/L。以空白样品为基体进行加标回收试验,测得回收率为79.8%~114%,相对标准偏差为0.3%~12%。  相似文献   

18.
建立了固相萃取、毛细柱气相色谱-电子捕获检测器定量分析水中硝基苯类化合物的分析方法。通过对固相萃取柱的选择、固相萃取条件(样品溶液的pH值、上样速度、上样体积、洗脱液选择及配比)的优化,得出了最佳实验条件。穿透体积可达1.5L,回收率在80%~105%,最小检出浓度在0.00037~0.072μg/L之间,均大大低于GB13194-91的规定。相对标准偏差在0.7%~5.3%之间。该方法准确、简单,重现性好、回收率高,污染小。  相似文献   

19.
建立了加速溶剂萃取-气相色谱质谱法同时测定34种有机氯农药(OCPs)和18种多氯联苯类化合物(PCBs)的方法。当取样量为10.0g时,52种有机化合物的检出限为0.03~0.29μg/kg,以空白样品为基体进行加标回收试验,平均回收率为44.7%~123.0%,相对标准偏差(RSD,n=7)为1.8%~21.5%。该方法灵敏度高,实现了低浓度有机化合物的定量分析,分析结果准确可靠,满足土壤和沉积物中34种有机氯农药和18种多氯联苯类化合物分析的要求。  相似文献   