1.
Yuan C  Weng CH 《Chemosphere》2006,65(1):88-96
An enhanced electrokinetic process for removal of metals (Cr, Cu, Fe, Ni, Pb, Zn) from an industrial wastewater sludge was performed. The electrokinetic experiments were conducted under a constant potential gradient (1.25 V cm(-1)) with processing fluids of tap water (TW), sodium dodecylsulfate (SDS) and citric acid (CA) for 5 days. Results showed that metal removal efficiency of heavy metals for EK-TW, EK-SDS and EK-CA systems are 11.2-60.0%, 37.2-76.5%, and 43.4-78.0%, respectively. A highest metal removal performance was found in EK-CA system. The removal priority of investigated metals from sludge by EK process was found as: Cu > Pb > Ni > Fe > Zn > Cr. The results of sequential extraction analysis revealed that the binding forms of heavy metals with sludge after electrokinetic process were highly depend upon the processing fluid operated. It was found that the binding forms of metals with sludge were changed from the more difficult extraction type (residual and sulfate fractions) to easier extraction types (exchangeable, sorbed, and organic fraction) after treatment by electrokinetic process. Results imply that if a proper treatment technology is followed by this EK process to remove metals more effectively, this treated sludge will be more beneficial for sludge utilization afterwards. Before it was reused, the risk associated with metals of more mobile forms to the environment need to be further investigated. The cost analysis was also evaluated for the investigated electrokinetic systems.  相似文献   

2.
Optimizing process parameters that affect the remediation time and power consumption can improve the treatment efficiency of the electrokinetic remediation as well as determine the cost of a remediation action. Lab-scale electrokinetic remediation of Pb-contaminated soils was investigated for the effect of complexant ethylenediaminetetraacetic acid (EDTA) and acetic acid and approaching anode on the removal efficiency of Pb. When EDTA was added to the catholyte, EDTA dissolved insoluble Pb in soils to form soluble Pb–EDTA complexes, increasing Pb mobility and accordingly removal efficiency. The removal efficiency was enhanced from 47.8 to 61.5 % when the EDTA concentration was increased from 0.1 to 0.2 M, showing that EDTA played an important role in remediation. And the migration rate of Pb was increased to 72.3 % when both EDTA and acetic acid were used in the catholyte. The “approaching anode electrokinetic remediation” process in the presence of both EDTA and acetic acid had a higher Pb-removal efficiency with an average efficiency of 83.8 %. The efficiency of electrokinetic remediation was closely related to Pb speciation. Exchangeable and carbonate-bounded Pb were likely the forms which could be removed. All results indicate that the approaching anode method in the presence of EDTA and acetic acid is an advisable choice for electrokinetic remediation of Pb-contaminated soil.  相似文献   

3.
Airflow rate is one of the most important parameters for the soil vapor extraction of contaminated sites, due to its direct influence on the mass transfer occurring during the remediation process. This work reports the study of airflow rate influence on soil vapor extractions, performed in sandy soils contaminated with benzene, toluene, ethylbenzene, xylene, trichloroethylene and perchloroethylene. The objectives were: (i) to analyze the influence of airflow rate on the process; (ii) to develop a methodology to predict the remediation time and the remediation efficiency; and (iii) to select the most efficient airflow rate. For dry sandy soils with negligible contents of clay and natural organic matter, containing the contaminants previously cited, it was concluded that: (i) if equilibrium between the pollutants and the different phases present in the soil matrix was reached and if slow diffusion effects did not occur, higher airflow rates exhibited the fastest remediations, (ii) it was possible to predict the remediation time and the efficiency of remediation with errors below 14%; and (iii) the most efficient remediation were reached with airflow rates below 1.2 cm(3)s(-1) standard temperature and pressure conditions.  相似文献   

4.
In this study, we evaluated the feasibility of in situ electrokinetic remediation for arsenic (As)-, copper (Cu)-, and lead (Pb)-contaminated soil, in a pilot-scale field application with two-dimensional electrode configurations. Square and hexagonal configurations with different electrode spacing, 1 m and 2?m, were investigated under a constant 100 V. A square configuration with electrode spacing of 2 m removed 61.5 % of As, 11.4 % of Cu, and 0.9 % of Pb, respectively, and a hexagonal configuration with the same spacing showed a higher removal efficiency in top (59 % of As, 0–0.5 m) and middle (53 % of As, 0.5–1.0 m) layers, but much lower removal efficiency in the bottom layer (1–1.5 m), which was thought to be due to groundwater flow through periodic rise and fall of tides. Fractionation analysis showed that As bound to Fe–Mn oxyhydroxide was the main form of As removed by the electrokinetic process. The two-dimensional configuration wasted less electrical energy by Joule heating, and required fewer electrode installations, compared to the one-dimensional electrode configuration.  相似文献   

5.
利用电动修复技术对铅污染土壤的修复进行了实验室研究,研究了修复时间和络合剂EDTA对电动修复效果的影响,分析了土壤重金属的迁移和变化特征。结果表明,在电场力作用下随着修复时间的增长污染物的去除率相应提高,去除率由修复时间5 d时的13%增加到15 d时的20%。以EDTA作为阴极控制液,EDTA可与硝酸铅反应形成溶解态的络合物,提高铅离子的移动性,从而提高修复效果。随着EDTA浓度由0.1 mol/L到0.2 mol/L,Pb的去除率由44.4%提高到61.5%,说明添加络合剂可以提高修复效果。另外,电动修复效果与铅的形态分布有密切关系,交换态和碳酸盐结合态有利于重金属铅的去除。  相似文献   

6.
Instead of direct current power supply, a series of electrokinetic remediation experiments driven by solar energy on fluorine-contaminated soil were conducted in a self-made electrolyzer, in order to reduce energy expenditure of electrokinetic remediation. After the 12-day electrokinetic remediation driven by solar energy, the removal efficiency of fluorine was 22.3 %, and electrokinetic treatment had an impact on changes in partitioning of fluorine in soil. It proved that the combination of electrokinetics and solar energy was feasible and effective to some extent for the remediation of fluorine-contaminated soil. Meanwhile, the experimental results also indicated that the electromigration was a more dominant transport mechanism for the removal of fluorine from contaminated soil than electroosmosis, and the weather condition was the important factor in affecting the removal efficiency.  相似文献   

7.
The system performance of a trickle bed biofilter for treating single and mixed benzene, toluene, ethylbenzene, and o-xylene (BTEX) vapors from waste gases was investigated under different gas flow rates and influent BTEX concentrations. When a single substrate was fed, removal efficiencies of greater than 90% could be achieved for the loads below 64 g benzene/m3/hr, 110 g toluene/m3/hr, 53 g ethylbenzene/m3/hr, and 55 g o-xylene/m3/hr. When a mixed substrate was fed, removal efficiencies of each compound could be above 90% at BTEX loads below 96 g/m3/hr. The trickle bed biofilter appears to be an effective treatment process for removing both single and mixed BTEX vapors with low to high loads. Under similar substrate loads, BTEX vapors were preferentially biodegraded in the order of toluene, benzene, o-xylene, and ethylbenzene. The volumetric removal rates (elimination capacities) of BTEX vapors for a single-substrate feed were higher than those for a mixed-substrate feed under similar substrate loads; these differences were enhanced at higher substrate loads and less significant for a preferred substrate.  相似文献   

8.
EDTA强化电动力学修复重金属复合污染土壤   总被引:2,自引:0,他引:2  
在自制的电动力学装置中,研究多种重金属复合污染土壤的电动力学修复,通过在阴极添加络合剂EDTA来提高修复效率。实验结果表明,EDTA的引入提高了修复过程中的电流值,且EDTA与重金属的络合提高了污染物向电极液的迁移效率,从而强化了电动力学修复效果。在设定的浓度(0、0.01、0.02、0.05和0.1 mol/L)中,0.1 mol/L的EDTA具有最佳的修复效率。在此实验条件下,污染土壤中的总铜、总铅和总镉的去除率分别为90.2%、68.1%和95.1%。电动力学修复后,对土壤重金属进行化学形态分析,发现电动力学修复显著改变了土壤重金属存在形态,修复后土壤中的铜、铅、镉主要以较稳定的有机态和残余态形式存在,显著降低了对周边生物和环境的毒害。  相似文献   

9.
Yuan C  Chiang TS 《Chemosphere》2007,67(8):1533-1542
An innovative remediation system of electrokinetic process coupled with permeable reaction barrier (PRB) was proposed for arsenic removal in soil matrix. Batch tests with PRB media of Fe(0) and FeOOH under potential gradient of 2 V cm(-1) for 5d duration were conducted to evaluate the removal mechanisms of arsenic. Arsenic enhancement of 1.6-2.2 times was achieved when a PRB system was installed in an electrokinetic system. A best performance was found in system with FeOOH layer located in the middle of elctrokinetic cell. This was largely because of higher surface area of FeOOH and the moving of HAsO(4)(2-) to the anode side by electromigration effect was inhibited by the electroosmosis flow. The surface characteristics of PRB media, which were qualified by SEM coupled with energy dispersive spectroscopy (EDS), were clearly confirmed that arsenic was found on the passive layer surface. Results indicated that the removal of As in EK/PRB systems was much more contributed by surface adsorption/precipitation on PRB media than by EK process. Furthermore among the electrical removal mechanisms, electromigration was predominant than electrosmotic flow. Surface adsorption and precipitation were respectively the principal removal mechanism under acid environment, e.g. near anode side, and under basic environment, e.g. near cathode side. The results reported in the present work will be beneficial to optimizing design of batch EK/PRB system and enlarging to the field scale system.  相似文献   

10.
Enhanced chemical oxidation of aromatic hydrocarbons in soil systems   总被引:5,自引:0,他引:5  
Kang N  Hua I 《Chemosphere》2005,61(7):909-922
Fenton's destruction of benzene, toluene, ethylbenzene, and xylene (BTEX) was investigated in soil slurry batch reactors. The purpose of the investigation was to quantify the enhancement of oxidation rates and efficiency by varying process conditions such as iron catalyst (Fe(II) or Fe(III); 2, 5, and 10mM), hydrogen peroxide (H2O2; 30, 150, 300 mM), and metal chelating agents (l-ascorbic acid, gallic acid, or N-(2-hydroxyethyl)iminodiacetic acid). Rapid contaminant mass destruction (97% after 3h) occurred in the presence of 300 mM H2O2 and 10 mM Fe(III). An enhanced removal rate (>90% removal after 15 min and 95% removal after 3h) was also observed by combining Fe(III), N-(2-hydroxyethyl)iminodiacetic acid and 300 mM H2O2. The observed BTEX mass removal rate constants (3.6-7.8 x 10(-4)s(-1)) were compared to the estimated rate constants (4.1-10.1 x 10(-3)s(-1)). The influence of non-specific oxidants loss (by reaction with iron hydroxides and soil organic matter) was also explored.  相似文献   

11.
Isosaari P  Sillanpää M 《Chemosphere》2010,81(9):1155-1158
The aim of this study was to investigate the feasibility of enhanced electrokinetic remediation technology for controlled leaching and collection of labile arsenic fractions from mine tailings. Direct current was applied to tailings for 20 d using ammonium oxalate and sodium hydroxide as enhancement solutions. Migration of arsenic was observed, resulting in 63-71% removal near the cathode but only 6-17% overall removal in the entire tailings matrix in 20 d. However, significant migration of arsenic towards the anode and accumulation in a collection well near the anode was observed, especially under alkaline conditions. Thus, treatment time and consumption of chemicals could probably be reduced by installing specific collection or adsorption zones near the anode. A relationship between electrokinetic mobility of arsenic and other elements and their extractability in sequential extraction tests was established, indicating that dissolution or desorption of the elements and thermodynamic conditions (pH and Eh gradient) played a bigger role in the electrokinetic removal process than electromigration of soluble ions.  相似文献   

12.
电动与渗透反应格栅联合修复镉污染地下水实验   总被引:5,自引:0,他引:5  
胡宏韬 《环境工程学报》2009,3(10):1773-1777
通过实验方法研究了地下水中镉污染的电动力学修复效果,并分析其迁移变化特征。实验结果表明,电动修复中由于阴阳两极的氧化还原反应造成电极附近pH值产生明显变化,其中阳极附近的pH值由开始时的7.0逐渐变小到6.8,而阴极附近则相反,由开始时6.9逐渐增大到9.1,表明土壤的酸碱条件变化明显。Cd浓度变化反映在自然渗透条件下含水层中重金属污染物的迁移能力较弱,阳极附近地下水中Cd的去除率仅8.4%,而在电场作用下地下水中重金属的浓度发生明显变化,使得重金属污染物能在电极附近富集而被去除,当实验电场强度为0.5 V/cm时,Cd在阴极的累积使得阳极附近地下水中去除率为72.9%,说明电动修复重金属Cd污染地下水的效果明显好于自然渗透状态。  相似文献   

13.
A numerical model of metabolic reductive dechlorination is used to describe the performance of enhanced bioremediation in fractured clay till. The model is developed to simulate field observations of a full scale bioremediation scheme in a fractured clay till and thereby to assess remediation efficiency and timeframe. A relatively simple approach is used to link the fermentation of the electron donor soybean oil to the sequential dechlorination of trichloroethene (TCE) while considering redox conditions and the heterogeneous clay till system (clay till matrix, fractures and sand stringers). The model is tested on lab batch experiments and applied to describe sediment core samples from a TCE-contaminated site. Model simulations compare favorably to field observations and demonstrate that dechlorination may be limited to narrow bioactive zones in the clay matrix around fractures and sand stringers. Field scale simulations show that the injected donor is expected to be depleted after 5 years, and that without donor re-injection contaminant rebound will occur in the high permeability zones and the mass removal will stall at 18%. Long remediation timeframes, if dechlorination is limited to narrow bioactive zones, and the need for additional donor injections to maintain dechlorination activity may limit the efficiency of ERD in low-permeability media. Future work should address the dynamics of the bioactive zones, which is essential to understand for predictions of long term mass removal.  相似文献   

14.
为了提高厌氧流化床微生物燃料电池(AFB-MFC)的性能,并为双室MFC寻找价廉、易得、无污染的阴极液,在曝气量16~24 L/h、温度(35±2)℃、回流量10.2 L/h、阴极底边距阴极室内底部17.3 cm、外电阻250 Ω、水力停留时间(HRT)14.0~14.9 h以及进水pH 7.81~8.37下,研究了阴极液及底物浓度对系统产电及废水处理性能的影响。结果表明,使用缓冲溶液、阳极室出水和自来水作阴极液时,自来水的产电性能最佳,阴极液种类不影响系统有机基质的去除。以自来水为阴极液时,阴极液pH及电导率随运行时间增加而增加,COD去除率为80.11%~89.29%,输出电压及功率密度开始随运行时间增加而增加,之后稳定在440~452 mV和48.40~51.08 mW/m2之间。增加底物浓度对COD去除率影响不大,而输出电压及功率密度随底物浓度增加而下降;底物COD浓度由3 307.09 mg/L增至9 520 mg/L时,COD去除率在85.77%~94.44%之间,输出电压及功率密度则分别由449 mV和50.40 mW/m2下降至406 mV和41.21 mW/m2。自来水作阴极液可避免二次污染及阴极液对阳极室微生物的影响,并得到高的产电能力。  相似文献   

15.
Luo Q  Wang H  Zhang X  Fan X  Qian Y 《Chemosphere》2006,64(3):415-422
In situ bioremediation is a safe and cost-effective technology for the cleanup of contaminated sites, but its remediation rate is usually very slow. This study attempted to accelerate the process of bioremediation by employing non-uniform electrokinetic transport processes to mix organic pollutants and degrading bacteria in soils under in situ conditions (namely, in situ bioelectrokinetic remediation) by use of an electrode matrix and a rotational operation mode. A bench-scale non-uniform electrokinetic system with periodic polarity-reversal was developed for this purpose, and tested by using a sandy loam spiked with phenol as a model organic pollutant. The results demonstrated that non-uniform electrokinetic processes could enhance the in situ biodegradation of phenol in the soil, the efficiency of which depended upon the operational mode of the electric field. Compared with the unidirectional operation and the bidirectional operation, the rotational operation could effectively stimulate the biodegradation of phenol in the soil if adopting appropriate time intervals of polarity-reversal and electrode matrixes. A reversal interval of 3.0 h and a square-shaped electrode matrix with four electrode couples appeared appropriate for the in situ biodegradation of phenol, at which a maximum phenol removal of 58% was achieved in 10d and the bioremediation rate was increased about five times as compared to that with no electric field applied. The results also showed that adopting a small polarity-reversal interval and an appropriate electrode array could produce a high and uniform removal of phenol from the soil. It is believed that in situ bioelectrokinetic remediation holds the potential for field application.  相似文献   

16.
Zhou DM  Deng CF  Cang L 《Chemosphere》2004,56(3):265-273
The effect of enhancement reagents on the efficiency of electrokinetic remediation of Cu contaminated red soil is evaluated. The enhancement agents were a mix of organic acids, including lactic acid+NaOH, HAc-NaAc and HAc-NaAc+EDTA. The soil was prepared to an initial Cu concentration of 438 mgkg(-1) by incubating the soil with CuSO4 solution in a flooded condition for 1 month. Sequential extraction showed that Cu was partitioned in the soil as follows: 195 mgkg(-1) as water soluble and exchangeable, 71 mgkg(-1) as carbonate bound and 105 mgkg(-1) as Fe and Mn oxides. The results indicate that neutralizing the catholyte pH maintains a lower soil pH compared to that without electrokinetic treatment. The electric currents varied depending upon the conditioning solutions and increased with an increasing applied voltage potential. The electroosmotic flow rate changed significantly when different conditioning enhancing reagents were used. It was observed that lactic acid+NaOH treatments resulted in higher soil electric conductivities than HAc-NaAc and HAc-NaAc+EDTA treatments. Ultimately, enhancement by lactic acid+NaOH resulted in highest removal efficiency (81% Cu removal) from the red soil. The presence of EDTA did not enhance Cu removal efficiencies from the red soil, because EDTA complexed with Cu to form negatively charge complexes, which slowly migrated toward the anode chamber retarding Cu2+ transport towards the cathode.  相似文献   

17.
Trickle-bed air biofilters (TBABs) are suitable for treating volatile organic compounds (VOCs) at a significantly high practical loading because of their controlled environmental conditions. The application of TBAB for treating styrene-contaminated air under periodic backwashing and cyclical nonuse periods at a styrene loading of 0.64-3.17 kg chemical oxygen demand (COD)/m3 x day was the main focus of this study. Consistent long-term efficient performance of TBAB strongly depended on biomass control. A periodic in situ upflow with nutrient solution under media fluidization, that is, backwashing, was approached in this study. Two different nonuse periods were employed to simulate a shutdown for equipment repair or during weekends and holidays. The first is a starvation period without styrene loading, and the second is a stagnant period, which reflects no flow passing through the biofilter. For styrene loadings up to 1.9 kg COD/m3 x day, removal efficiencies consistently above 99% were achieved by conducting a coordinated biomass control strategy, that is, backwashing for 1 hr once per week. Under cyclical nonuse periods for styrene loadings up to 1.27 kg COD/m3 x day, stable long-term performance of the biofilter was maintained at more than 99% removal without employing backwashing. No substantial impact of nonuse periods on the biofilter performance was revealed. However, a coordinated biomass control by backwashing subsequently was unavoidable for attaining consistently high removal efficiency at a styrene loading of 3.17 kg COD/m3 x day. As styrene loading was increased, reacclimation of the biofilter to reach the 99% removal efficiency following backwashing or the nonuse periods was delayed. After the non-use periods, the response of the biofilter was a strong function of the biomass in the bed. No significant difference between the effects of the two different nonuse periods on TBAB performance was observed during the study period.  相似文献   

18.
The feasibility of electrokinetic remediation of copper-contaminated soil was evaluated following eight days of electroreclamation. The results indicate that electrokinetic reclamation of Cu is totally ineffective in soil composed primarily of clay minerals and organic matter. The strong absorption of copper by this kind of soil, in our view mainly a result of retention by the clay component, makes it resistant to mobilization by the electrogenerated acidic front as well as by citrates (the competitors of natural chelating agents, i.e., humates). Such conditions, while adverse for the electroremediation process, may cause this kind of soil to act as a natural barrier to the leaching of copper ions.  相似文献   

19.
施加电压对铬污染土壤电动修复的影响   总被引:4,自引:0,他引:4  
试验研究了不同电压条件下电动修复去除效率和单位能耗随施加电压的变化关系,探讨了电动修复经济有效的电压范围.试验选用重铬酸钾作为污染物,配制高岭土中Cr(Ⅵ)初始质量分数为100 mg/kg和500 mg/kg,含水量为50%,试验运行48 h,用乙酸控制阴极pH在4~7之间,施加一系列不同直流电压.试验结果表明,随着施加电压升高,去除效率增大,电压升高到1 V/cm时,去除效率显著升高,2种试验土壤去除效率分别为76.7%和89.8%;同时随着施加电压增加,电能消耗显著增加,与电压呈现线性递增和幂指数递增关系;综合去除效率和单位能耗2种因素,对于试验所研究的土壤,1~1.5 V/cm的电压是较为经济有效的.  相似文献   

20.
A suspended-growth bioreactor (SGB) was operated for the treatment of a gaseous stream mimicking emissions generated at a leather industrial company. The main volatile organic compounds (VOCs) present in the gaseous stream consisted of 1-methoxy-2-propanol, 2,6-dimethyl-4-heptanone, 2-butoxyethanol, toluene and butylacetate. A microbial consortium able to degrade these VOCs was successfully enriched. A laboratory-scale SGB was established and operated for 210-d with an 8h cycle period and with shutdowns at weekends. Along this period, the SGB was exposed to organic loads (OL) between 6.5 and 2.3 x 10(2) g h(-1) m(-3). Most of the compounds were not detected at the outlet of the SGB. The highest total VOC removal efficiency (RE) (ca 99%) was observed when an OL of 1.6 x 10(2) g h(-1) m(-3) was fed to the SGB. The maximum total VOC elimination capacity (1.8 x 10(2) g h(-1) m(-3)) was achieved when the OL applied to the SGB was 2.3 x 10(2) g h(-1) m(-3). For all the operating conditions, the SGB showed high levels of degradation of toluene and butylacetate (RE approximately equal to 100%). This study also revealed that recirculation of the gaseous effluent improved the performance of the SGB. Overall, the SGB was shown to be robust, showing high performance after night and weekend shutdown periods.  相似文献   