首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Modern society grapples with large amounts of household waste. The anaerobic digestion of this waste offers a promising source for energy-rich biogas production but generates high toxic effluents that require treatment before reuse or disposal into the environment. This study aimed to investigate three techniques, namely coagulation/flocculation, electro-coagulation, and activated sludge, in terms of efficiency in the treatment of these effluents. It also aimed to assess their toxicity effects on the germination and growth of durum wheat Triticum aestivum L. seeds before and after 6 days of treatment. Activated sludge was most efficient in reducing chemical oxygen demand, turbidity, and conductivity (95.7 %, 15.8 %, and 37.5 %, respectively). The effluent treated with this technique induced a marked delay in germination (low mean time of germination) and a significant reduction in the percentages of seed germination and root and leaf growths. It was also noted to strongly induce lipid peroxidation in roots and leaves, which presumably explained the germination/growth inhibition of the wheat seeds. The effluent also induced marked lipid peroxidation effects and strongly inhibited the activities of butyrylcholinesterase in mice bone marrows. The effluent shows a high ability to inhibit the growth of three microalgae; these endpoints are useful tools to biomonitor the physico-chemical quality of this wastewater. Overall, while no significant alterations were observed in terms of animal and vegetable toxicities when the effluent was treated by coagulation/flocculation, activated sludge treatment proved efficient in reducing the toxicities induced by the untreated effluents. The results indicate that the application of this technique is promising with regards to attaining efficient, eco-friendly, and cost-effective strategies for the management and treatment of household waste.  相似文献   

2.
Batt AL  Kim S  Aga DS 《Chemosphere》2007,68(3):428-435
The occurrence of ciprofloxacin, sulfamethoxazole, tetracycline, and trimethoprim antibiotics in four full-scale wastewater treatment plants (WWTPs) that differ in design and operating conditions was determined. The WWTPs chosen utilized a variety of secondary removal processes, such as a two stage activated sludge process with a nitrification tank, extended aeration, rotating biological contactors, and pure oxygen activated sludge. Several of the WWTPs also employed an advanced treatment process, such as chlorination and UV radiation disinfection. The detected concentrations (microg/l) ranged from 0.20 to 1.4 for ciprofloxacin, 0.21 to 2.8 for sulfamethoxazole, 0.061 to 1.1 for tetracycline, and 0.21 to 7.9 for trimethoprim. The overall percent difference in the concentrations of the antibiotics in the effluent and influent of these antibiotics differed between plants and ranged from 33% to 97%. Based on these four full-scale WWTPs evaluated, the apparent removal of organic micropollutants in wastewater is dependent on a combination of biological and physico-chemical treatment processes and operating conditions of the treatment system.  相似文献   

3.
In this study the fate of pharmaceuticals and personal care products which are irrigated on arable land with treated municipal wastewater was investigated. In Braunschweig, Germany, wastewater has been irrigated continuously for more than 45 years. In the winter time only the effluent of the sewage treatment plant (STP) of Braunschweig is used for irrigation, while during summer digested sludge is mixed with the effluent. In the present case study six wells and four lysimeters located in one of the irrigated agricultural fields were monitored with regard to the occurrence of 52 pharmaceuticals and two personal care products (PPCPs; e.g. betablockers, antibiotics, antiphlogistics, carbamazepine, musk fragrances, iodinated contrast media (ICM) and estrogens). No differences in PPCP pollution of the groundwater were found due to irrigation of STP effluents with and without addition of digested sludge, because many polar compounds do not sorb to sludge and lipophilic compounds are not mobile in the soil-aquifer. Most of the selected PPCPs were never detected in any of the lysimeter or groundwater samples, although they were present in the treated wastewater irrigated onto the fields. In the groundwater and lysimeter samples primarily the ICM diatrizoate and iopamidol, the antiepileptic carbamazepine and the antibiotic sulfamethoxazole were detected up to several mugl(-1), while the acidic pharmaceuticals, musk fragrances, estrogens and betablockers were likely sorbed or transformed while passing the top soil layer. Potential estrogenic effects are likely to disappear after irrigation, since the most potent steroid estrogens were not measurable.  相似文献   

4.
This study evaluated the use of steam explosion as a pretreatment for municipal wastewater treatment sludges and biosolids as a technique for enhancing biogas generation during anaerobic digestion. Samples of dewatered anaerobic digester effluent (biosolids) and a mixture of thickened waste activated sludge (TWAS) and biosolids were steam-exploded under differing levels of intensity in this study. The results indicate that steam explosion can solublize components of these sludge streams. Increasing the intensity of the steam-explosion pressure and temperature resulted in increased solublization. The steam-explosion pretreatment also increased the bioavailability of sludge components under anaerobic digestion conditions. Increasing the steam-explosion intensity increased the ultimate yield of methane during anaerobic digestion. Batch anaerobic digestion tests suggested that pretreatment at 300 psi was the most optimal condition for enhanced biogas generation while minimizing energy input. Semicontinuous anaerobic digestion revealed that the results that were observed in the batch tests were sustainable in prolonged operation. Semicontinuous digestion of the TWAS/biosolids mixture that was pretreated at 300 psi generated approximately 50% more biogas than the controls. Semicontinuous digestion of the pretreated biosolids resulted in a 3-fold increase in biogas compared with the controls. Based on capillary suction test results, steam-explosion pretreatment at 300 psi improved the dewaterability of the final digested sludge by 32 and 45% for the TWAS/ biosolids mixture and biosolids, respectively, compared with controls. The energy requirements of the nonoptimized steam-explosion process were substantially higher than the additional energy produced from enhanced digestion of the pretreated sludge. Substantial improvements in energy efficiency will be required to make the process viable from an energy perspective.  相似文献   

5.

Surgical cotton production has drastically been increased in the past few years due to excessive use by medical health professionals especially in countries like India, which is among the top three exporters of cotton worldwide. The effluent generated from surgical cotton industries differ from textile effluents by the conspicuous absence of dyeing chemicals. This wastewater has a high concentration of suspended particles, COD, dissolved ions, organic carbon, and alkaline pH. Several studies have been published on the treatment of textile effluents and the degradation of dyeing chemicals, while the treatment studies on surgical cotton wastewater have been rarely reported in spite of their potential to cause pollution in receiving land/water bodies. Activated sludge microbes have been extensively studied and well documented in the treatment of several industrial effluent but does not match to the production of valuable biomass from algae. The global energy demand has prompted the scientific community to investigate and explore the possibility of using algae for energy production with simultaneous wastewater treatment. To the best of the authors’ knowledge, no research articles have been published which compare the effectiveness of activated sludge microorganisms, microalgae, and macroalgae in removing contaminants from real wastewater. To date, there is a knowledge gap in understanding and selecting the right choice of biological system for effective and economical effluent treatment. In an attempt to minimize this gap, carbon removal by microalgae, macroalgae, and activated sludge microbes were investigated on real effluent from surgical cotton industries. It was observed that the strain of Chlorella vulgaris could dissipate 83% of COD from real wastewater, while consortia of macroalgae (consisting predominantly of Ulvaceae and Chaetomorpha) and activated sludge microbes could remove 81% and 69% of the carbon, respectively. The microalgal growth (in terms of wet weight) increased from 0.15 to 0.3 g, whereas the macroalgal wet weight increased from 1.5 to 3 g in over 7 days of batch experiments conducted in triplicates. This indicated the superlative performance of microalgae over activated sludge microbes in carbon dissipation.

  相似文献   

6.
Occurrence and fate of heavy metals in the wastewater treatment process   总被引:19,自引:0,他引:19  
The occurrence and the fate of heavy metals (Cd, Pb, Mn, Cu, Zn, Fe and Ni) during the wastewater treatment process were investigated in the wastewater treatment plant (WTP) of the city of Thessaloniki, northern Greece, operating in the activated sludge mode. For this purpose, wastewater and sludge samples were collected from six different points of the plant, namely, the influent (raw wastewater, RW), the effluent of the primary sedimentation tank (primary sedimentation effluent, PSE), the effluent of the secondary sedimentation tank (secondary sedimentation effluent, SSE), sludge from the primary sedimentation tank (primary sludge, PS), activated sludge from the recirculation stream (activated sludge, AS), and the digested/dewatered sludge (final sludge, FS).

The distribution of metals between the aqueous and the solid phase of wastewater was investigated. Good exponential correlation was found between the metal partition coefficient, logKp, and the suspended solids concentration. The mass balance of heavy metals in the primary, secondary and the whole treatment process showed good closures for all metal species. The relative distribution of individual heavy metals in the treated effluent and the sludge streams indicated that Mn and Cu are primarily (>70%) accumulated in the sludge, while 47–63% of Cd, Cr, Pb, Fe, Ni and Zn remain in the treated effluent.  相似文献   


7.
以某城市污水处理厂剩余污泥为对象,通过实验研究了超声与次氯酸钠预处理对污泥的溶胞效果,以及对后续厌氧消化的影响。结果表明,超声与次氯酸钠耦合作用最优操作条件为超声声能密度1.0 W/mL,作用时间50 min。在此条件下,次氯酸钠投加量为4.023 mg/g SS时,对污泥厌氧消化改善效果最明显,剩余污泥产气率及甲烷含量较对照组分别提高了69.73%和10%。同时污泥VSS去除率由11.11%提高到21.24%,在一定程度上实现了污泥减量。  相似文献   

8.
金属铁铝对混凝强化初沉污泥中温厌氧消化的影响   总被引:1,自引:0,他引:1  
选取FeCl3和AlCl3·6H2O作为混凝剂对城市污水进行一级强化混凝处理,降低二级生物处理的进水负荷,减少污水生物处理系统的能量消耗。主要研究混凝过程投加的金属盐对一级强化混凝产生的初沉污泥中温厌氧消化的影响。和剩余污泥相比,初沉污泥更适合厌氧消化处理,污泥降解性能和产气性能更高。当采用城市污水一级强化混凝处理时,污泥中的金属和金属盐水解引起的pH降低,使混凝强化初沉污泥的厌氧消化受到一定抑制。随着污泥中铝含量的降低和铁含量的增加,厌氧消化的COD降解率和挥发性固体(VS)降解率逐渐升高,生物气产量逐渐增大,产气速率加快。当混凝强化初沉污泥只含有铁时(铁含量为10.16 mg/L),混凝强化初沉污泥厌氧消化效果最好,产气稳定,而且产气速率高,生物气产量为237 mL,生物气甲烷含量为55.5%,降解单位VS产气量为0.80 L/g,均高于其他含铝的混凝强化初沉污泥。污泥中的铁对初沉污泥厌氧消化的抑制作用远远小于铝的作用,说明铁盐适合用于城市污水的一级强化混凝处理。  相似文献   

9.
废水处理工艺中抗生素类污染物的存在可能会对生物处理过程产生长期而深远的影响,为探明此类污染物对废水生物处理主体活性污泥性能等方面的影响,采用间歇培养法研究了活性污泥法处理污水时,抗生素类污染物的存在对活性污泥性能如胞外聚合物(EPS)、污染物处理能力、脱氢酶活性和群落结构的影响。结果表明,抗生素的存在会导致活性污泥的胞外聚合物总量及其主要组分蛋白质和多糖增加,以产生保护屏障;且由于污泥絮体解体,细胞破裂导致EPS中DNA和色氨酸含量增加。同时,由于蛋白质大量增加引起的表面负电荷的增加,使污泥疏水性增强,絮凝性能恶化;污泥絮体解体导致污泥颗粒变小,SVI也随之下降;在活性污泥脱氢酶活性急剧下降的同时,出水TOC迅速升高。此外,抗生素类污染物在抑制活性污泥中大部分细菌的同时,对部分菌群也有刺激生长作用,最终导致活性污泥生物群落结构的改变。四环素类抗生素对活性污泥的EPS和絮凝沉降性能的影响大于磺胺类,而对污水处理能力和群落结构的影响则不如磺胺类。抗生素类污染物的长期存在会对活性污泥沉降性能、絮凝性能、脱氢酶活性以及活性污泥群落结构等产生一系列负面影响,进而影响污染物去除效果,导致出水水质恶化。  相似文献   

10.
The treatment efficiency, as toxicity removal, of complex effluents from the Industrial District of Cama?ari (BA, Brazil), after biological treatment with activated sludge was evaluated using Microtox. Samples of the equalised effluent (EE) were collected prior to treatment together with samples of the treated effluent (TE), which remained 24 h in the treatment plant. Rehydrated colonies of Vibrio fischeri were exposed to sequential dilutions of EE and TE to assess luminosity interference. Values for EC50 were calculated, together with the respective toxicity units. In all, twenty assays of each effluent type were carried out and the mean toxicity removal was 92.71%, while the chemical oxygen demand (COD) presented mean reduction of 83.04%. There was a variability of an order of magnitude between the Microtox results for the two types of effluents. The mean EC50 values were 2.12 for EE and 47.78% for TE. In spite of its weakness in some conditions, the Microtox system demonstrated to work adequately in assessing effluent toxicity removal in this treatment plant and therefore can be used for further toxicity removal programs.  相似文献   

11.
Anaerobic inhibition and biodegradation of antibiotics in ISO test schemes   总被引:2,自引:0,他引:2  
Gartiser S  Urich E  Alexy R  Kümmerer K 《Chemosphere》2007,66(10):1839-1848
Municipal sewage is the main exposure route for antibiotics that are used in human medical care. Antibiotics that adsorb to the primary sludge and/or sur-plus activated sludge will enter the anaerobic digesters of municipal sewage treatment plants. Here anaerobic biodegradation or inhibition of anaerobic bacteria resulting in a disturbance of the process might occur. ISO standards 13641 (2003) and 11734 (1999) were used for assessing the anaerobic inhibition of 16 and the anaerobic biodegradability of 9 antibiotics respectively. Digestion sludge from a municipal sewage treatment plant (1g/l d.s.) was used as inoculum in both tests. In ISO 13641 (2003) most antibiotics showed only moderate inhibition effects after a 7 day incubation period, with EC50 values between 24 mg/l and more than 1000 mg/l (equal to mg/g d.s.). In contrast, metronidazol was decisively toxic to anaerobic bacteria with an EC50 of 0.7 mg/l. In the anaerobic degradation tests according to ISO standard 11734 (1995), only benzylpenicillin showed certain ultimate biodegradation after 60 days and most antibiotics inhibited the digesting sludge in the respective parallel tested inhibition controls. Thus the inhibition of anaerobic bacteria by antibiotics observed in the degradation tests was higher than expected from the results of the inhibition tests. The possible explanations are that distinct substrates are used (yeast extract versus sodium benzoate), that the digestion sludge loses activity during the washing steps performed for the degradation tests and that the exposure time in the degradation tests was 8 times longer than in the inhibition test.  相似文献   

12.
废水处理工艺中抗生素类污染物的存在可能会对生物处理过程产生长期而深远的影响,为探明此类污染物对废水生物处理主体活性污泥性能等方面的影响,采用间歇培养法研究了活性污泥法处理污水时,抗生素类污染物的存在对活性污泥性能如胞外聚合物(EPS)、污染物处理能力、脱氢酶活性和群落结构的影响。结果表明,抗生素的存在会导致活性污泥的胞外聚合物总量及其主要组分蛋白质和多糖增加,以产生保护屏障;且由于污泥絮体解体,细胞破裂导致EPS中DNA和色氨酸含量增加。同时,由于蛋白质大量增加引起的表面负电荷的增加,使污泥疏水性增强,絮凝性能恶化;污泥絮体解体导致污泥颗粒变小,SVI也随之下降;在活性污泥脱氢酶活性急剧下降的同时,出水TOC迅速升高。此外,抗生素类污染物在抑制活性污泥中大部分细菌的同时,对部分菌群也有刺激生长作用,最终导致活性污泥生物群落结构的改变。四环素类抗生素对活性污泥的EPS和絮凝沉降性能的影响大于磺胺类,而对污水处理能力和群落结构的影响则不如磺胺类。抗生素类污染物的长期存在会对活性污泥沉降性能、絮凝性能、脱氢酶活性以及活性污泥群落结构等产生一系列负面影响,进而影响污染物去除效果,导致出水水质恶化。  相似文献   

13.
To understand the transport and fate of antibiotic resistance genes in wastewater treatment plants, 12 resistance genes (ten tetracycline resistance genes, two sulfonamides genes) and class 1 integron gene (intI1) were studied in five wastewater treatment plants with different treatment processes and different sewage sources. Among these resistance genes, sulfonamides genes (sul1 and sul2) were of the most prevalent genes with detection frequency of 100 %. The effluent water contained fewer types of resistance genes than the influent in most selected plants. The abundance of five quantified resistance genes (tetG, tetW, tetX, sul1, and intI1) decreased in effluent of plants treating domestic or industrial wastewater with anaerobic/aerobic or membrane bioreactor (MBR) technologies, but tetG, tetX, sul1, and intI1 increased along the treatment units of plants treating vitamin C production wastewater by anaerobic/aerobic technology. In plant treating cephalosporins production wastewater by UASB/aerobic process, the quantities of tetG, tetX, and sul1 first decreased in anaerobic effluent water but then increased in aerobic effluent water.  相似文献   

14.
Literature shows that full-scale pure-oxygen activated sludge (O2-AS) wastewater treatment plants (WWTPs) generate effluents with higher dissolved-organic carbon (DOC) concentrations and larger high-molecular-weight fractions compared to air-activated-sludge (Air-AS) WWTP effluents. The purpose of this paper was to evaluate how gas supplied (air vs. pure oxygen) to sequencing-batch reactors affected DOC transformations. The main conclusions of this paper are (a) O2-AS effluent DOC is more refractory than air-AS effluent DOC; and (b) O2-AS systems may have higher five-day biochemical oxygen demand removals than air-AS systems; however, in terms of COD and DOC removal, air-AS systems are better than O2-AS systems. Analysis of a database from side-by-side O2- and air-AS pilot tests from literature supported these observations.  相似文献   

15.
实际污水与模拟污水活性污泥系统的特性差异   总被引:2,自引:0,他引:2  
实验中经常采用人工配置的模拟生活污水,为了研究其与实际生活污水活性污泥系统的特性差异,采用2个序批式间歇反应器(SBR)进行平行实验(厌氧、好氧方式运行),系统地考察了在进水主要组分和运行参数相同的情况下,不同原水对活性污泥系统脱氮、除磷、比好氧速率、污泥絮体形态和出水水质等方面的影响。结果表明,模拟污水系统的硝化活性强于实际污水系统,两者的平均硝化速率分别为7.43 mg NH4+-N/(L.h)和5.55 mg NH4+-N/(L.h)。在前置厌氧段,模拟污水系统的释磷量比实际污水系统高出36.45%。两者在后续好氧阶段都能够充分吸磷。模拟污水系统的平均比好氧速率(SOUR)高达64.54 mg O2/(g MLSS.h),而实际污水系统的则只有32.81 mg O2/(g MLSS.h)。模拟污水系统的污泥絮体疏松,粒径小,形状不规则,沉降性差,沉后出水平均悬浮物浓度(SS)为20 mg/L;而实际污水系统的污泥絮体则密实、粒径大,沉降性好,沉后水十分清澈,SS几乎检测不出。  相似文献   

16.
A new way of generating Class A sludge using microwaves was evaluated through a series of laboratory-scale experiments. Microwaves provide rapid and uniform heating throughout the material. Other benefits of microwave treatment include instant and accurate control and selective and concentrated heating on materials, such as sludge, that have a high dielectric loss factor. Sludge was irradiated with 2450-MHz microwaves, and fecal coliforms were counted. Fecal coliforms were not detected at 65 degrees C for primary sludge and anaerobic digester sludge and at 85 degrees C for waste activated sludge when sludge was irradiated with 2450-MHz microwaves. During the bench-scale anaerobic digester operation, the highest average log reduction of fecal coliforms was achieved by the anaerobic digester fed with microwave-pretreated sludge (> or = 2.66 log removal). The anaerobic digester fed with microwave-irradiated sludge was more efficient in inactivation of fecal coliforms than the other two digesters fed with raw sludge and externally heated sludge, respectively. It took more than three hydraulic retention times for a bench-scale mesophilic anaerobic digester to meet Class A sludge requirements after feeding microwave-irradiated sludge. Class A sludge can be produced consistently with a continuously fed mesophilic anaerobic digester if sludge is pretreated with microwaves to reach 65 degrees C.  相似文献   

17.
The effects of wastewater treatment on the proportion of Escherichia coli and Enterococcus sp. resistant to specific antibiotics were investigated at two facilities in Davis County, Utah, one of which received hospital waste. Samples were taken from the influent, effluent before disinfection, and secondary anaerobic sludge digester effluent. There was very little difference in antibiotic resistance among E. coli in the inflow waters of the plants but the plant receiving hospital waste had a significantly higher proportion of antibiotic resistant Enterococcus. The effect of wastewater treatment on antibiotic resistance was more pronounced on enterococci than E. coli. Although some increases in antibiotic resistance were observed, the general trend seemed to be a decrease in resistance, especially in the proportion of multidrug resistant Enterococcus sp.  相似文献   

18.
Effluents from a night-soil treatment plant, where night-soil was aerobically treated by an activated sludge process, were irradiated with a UV lamp excluding short wavelengths less than 300 nm as a model of exposure to sunlight and the mutagenicities of the ethylacetate extracts from the irradiated effluents were assayed using Salmonella typhimurium TA98. The extracts exhibited mutagenicity toward S. typhimurium TA98 in the absence of rat liver S9 fraction only when the effluents were fortified with nitrite ion (more than 6 ppm) by over aeration or by artificial addition of nitrite, indicating that a limiting factor for mutagen formation is nitrite ion concentration. Nine organic-N-containing compounds as models of the organic components in the effluent were also irradiated and direct-acting potent mutagens were found to be produced from such compounds having indole moiety as indole, oxindole, tryptophan and tryptamine.  相似文献   

19.
选取FeCl3和AlCl2·6H2O作为混凝剂对城市污水进行一级强化混凝处理,降低二级生物处理的进水负荷,减少污水生物处理系统的能量消耗。主要研究混凝过程投加的金属盐对一级强化混凝产生的初沉污泥中温厌氧消化的影响。和剩余污泥相比,初沉污泥更适合厌氧消化处理,污泥降解性能和产气性能更高。当采用城市污水一级强化混凝处理时,污泥中的金属和金属盐水解引起的pH降低,使混凝强化初沉污泥的厌氧消化受到一定抑制。随着污泥中铝含量的降低和铁含量的增加,厌氧消化的COD降解率和挥发性固体(Vs)降解率逐渐升高,生物气产量逐渐增大,产气速率加快。当混凝强化初沉污泥只含有铁时(铁含量为10.16mg/L),混凝强化初沉污泥厌氧消化效果最好,产气稳定,而且产气速率高,生物气产量为237mL,生物气甲烷含量为55.5%,降解单位Vs产气量为0.80L/g,均高于其他含铝的混凝强化初沉污泥。污泥中的铁对初沉污泥厌氧消化的抑制作用远远小于铝的作用,说明铁盐适合用于城市污水的一级强化混凝处理。  相似文献   

20.
Abstract

This paper presents a comparative assessment of the cost and quality of treatment of tannery wastewater in India by two common effluent treatment plants (CETPs) constructed for two tannery clusters, at Jajmau (Kanpur) and at Unnao in the state of Uttar Pradesh, India. The Jajmau plant is upflow anaerobic sludge blanket (UASB) process-based, while the Unnao plant is activated sludge process (ASP)-based. Investigations indicated that the ASP-based plant was superior in all respects. Total annualized costs, including capital and operation and maintenance costs, for the UASB and ASP plants were Rs. 4.24 million/million liters per day (MLD) and Rs. 3.36 million/MLD, respectively. Land requirements for the two CETPs were 1.4 hectares/MLD and 0.95 hectares/MLD, respectively. Moreover, the treated UASB effluent had higher biochemical and chemical oxygen demand (BOD/COD) and considerable amounts of other undesirable constituents, like chromium (Cr) and sulfide, as compared with the ASP effluent, which had lower BOD/COD and negligible concentration of sulfide and Cr. Sludge production from the UASB-based plant was also higher at 1.4 t/day/MLD, in comparison to the sludge production of 0.8 t/day/MLD for the ASP-based plant. Also, the entire sludge produced in the UASB-based plant was Cr-contaminated and, hence, hazardous, while only a small fraction of the sludge produced in the ASP-based plant was similarly contaminated. The results of this study are at variance with the conventional wisdom of the superiority of anaerobic processes for tannery waste-water treatment in tropical developing countries like India.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号