首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 10 毫秒
1.
Among the objectives of the EPA’s Superfund Innovative Technology Evaluation (SITE) Program are two which pertain to the issue of economics: 1. That the program will provide a projected cost for each treatment technology demonstrated.

2. That the program will attempt to identify and remove impediments to the development and commercial use of alternative technologies.1

The SITE Program has fostered a special relationship between elements of the public and private sector. In turn, this has created a unique set of problems. These problems are most apparent where objectives of the public and private sector conflict, as in the area of cost economics. One concern of the SITE Program is to provide the public with an impartial analysis of each technology’s cost. Just as important is the need to be sensitive to the demands of the competitive economic environment which face every firm selling innovative technology (especially when the goal is to promote the commercial use of new technologies).

An early concern of the SITE Program was to design a methodology for projecting and reporting costs which tried to balance the needs of these two groups. Toward this end, four issues were identified which were thought to have a significant impact on the SITE Program's ability to generate useful cost projections. An analysis of these issues led to the creation of a simple five-part cost methodology. This paper will review the nature of these problems and will describe the methodology which addresses them. Finally, a review of cost data gathered from the first nine demonstrations will be presented.  相似文献   

2.
3.
California Air Resources Board (CARB) staff developed a phased integrated approach to implement the Standing Air Monitoring Work Group’s (SAMWG) quality assurance requirements. This approach separates quality assurance requirements into a single project with a management plan and manager, and assigns each requirement to one of three key task areas—standardized methods and procedures measurement standards and tests, and audits. Tasks are assigned priorities and a detailed management plan is developed with SAMWG dates as milestones.

Benefits of the phased integrated approach are a streamlined, flexible quality assurance program; maximum utilization of personnel and resources; timely implementation of SAMWG requirements; a uniform quality assurance program applied to state, local, and private industry monitoring programs; and data with documented precision and accuracy. Additionally, peculiarities of procedures and analyzers that lead to data inaccuracies are quickly identified and corrected.  相似文献   

4.
5.
6.
Solvent extraction of contaminated soils, sludges and sediments has been successfully completed at a number of Superfund sites. Each commercialized process uses a unique operating system to extract organic contaminants from solids. These operating systems may be classified by the properties of the solvents each utilizes: (1) standard solvents, (2) near-critical fluids/liquified gases, and (3) critical solution temperature solvents. Pretreatment and post-treatment requirements vary depending upon the operating systems of the solvent extraction system. Future demonstrations of these technologies by the U.S. EPA’s Superfund Innovative Technology Evaluation Program will provide additional information regarding the efficacy of these processes.  相似文献   

7.
以《全国污染源普查条例》为依据,结合工业污染源调查、排污申报以及环境统计的体会,阐述了影响污染源普查的质量内涵、制约因素,提出了相应的对策,对污染源普查具有一定的借鉴作用。  相似文献   

8.
水环境监测的质量控制与保证措施   总被引:1,自引:0,他引:1  
介绍了质量控制和质量保证体系,详细论述了质量监控方法及其注意事项,为样品监测的精确性提供了保障。  相似文献   

9.
Abstract

The U.S. Environmental Protection Agency (EPA) Quality Assurance (QA) Guidance Document 2.12: Monitoring PM2.5 in Ambient Air Using Designated Reference or Class I Equivalent Methods1 (Document 2.12) requires conditioning of PM2.5 filters at 20-23 °C and 30-40% relative humidity (RH) for 24 hr prior to gravimetric analysis. Variability of temperature and humidity may not exceed ±2 °C and ±5% RH during the conditioning period. The quality assurance team at EPA Region 2’s regional laboratory designed a PM2.5 weighing facility that operates well within these strict performance requirements.

The traditional approach to meeting the performance requirements of Document 2.12 for PM2.5 filter analysis is to build a walk-in room, with costs typically exceeding $100,000. The initial one-time capital cost for the laboratory at EPA’s Edison, NJ, facility was approximately $24,000. Annual costs [e.g., National Institute of Standards and Technology (NIST) recertifications and nitrogen replacement cylinders used for humidity control] are approximately $500. The average 24-hr variabilities in temperature and RH in the Region 2 weighing chamber are small, ±0.2 °C and ±0.8% RH, respectively. The mass detection limit for the PM2.5 weighing system of 47-mm stretched Teflon (lab blank) filters is 6.3 μg. This facility demonstrates an effective and economical example for states and other organizations planning PM2.5 weighing facilities.  相似文献   

10.
The Superfund Innovative Technology Evaluation (SITE) Program is now in its sixth year of demonstrating technologies applicable to Superfund sites. The SITE Program, conducted by the U.S. Environmental Protection Agency's Risk Reduction Engineering Laboratory, is intended to accelerate the use of new and innovative treatment processes as well as evaluate innovative measurement and monitoring techniques. Within the SITE Program, the Demonstration Program and the Emerging Technologies Program are responsible for innovative/alternative waste treatment technology development. Separate and parallel activities are progressing for development and evaluation of measuring and monitoring technologies as well as technology transfer operations.  相似文献   

11.
Collaborative testing is the traditional means used to establish the precision of test methods. The role that quality assurance plays in the collaborative testing of U.S. Environmental Protection Agency stationary source test methods is presented. The applicability of the quality assurance procedures presented for routine use in compliance testing is also described.  相似文献   

12.
13.
The initial state implementation plans concentrated on attainment of the ambient air quality standards in the relatively polluted areas of the country. Many of these plans must now be modified to ensure that the ambient standards will be maintained for the foreseeable future, and to ensure that significant deterioration of air quality in clean areas of the country is prevented.

The existing implementation plans currently contain many measures which are applicable to the maintenance and deterioration efforts, but additional measures must also be developed. Many of these additional measures will involve future planning activities—most common of which will be land use planning activities.

The point is made that, after existing sources have reduced their emissions to the lowest practical level, further air pollution control can only be accomplished by implementing rational planning procedures for management of any new sources of air pollution. This will require extensive cooperation among the air pollution control community; regional, state, and local planning agencies; state and local governments; and the general public in order to ensure that future land use plans include appropriate air quality considerations.  相似文献   

14.
介绍了扬中市环境监测站在创建实验室认可的过程中,将环境监测全过程的质量保证措施纳入质量体系文件,并通过检查实施情况,实现对环境监测全过程的质量管理。  相似文献   

15.
16.
质量控制和质量保证是水环境监测工作的重要组成部分,质量体系是实验室内部实施质量管理的法规,覆盖了监测样品、监测过程、仪器设备、人员素质、设施与环境、量值溯源与校准、检验方法和化学试剂等全部质量控制要求。能够准确地反应水环境质量现状和预测污染的发展趋势。  相似文献   

17.
田湾核电站外围辐射环境监测工作的质量保证   总被引:1,自引:0,他引:1  
总结了田湾核电站外围辐射环境监测中的质量保证实施情况,包括:人员培训和考核,仪器设备溯源,样品采集、运输、贮存及生物样品前处理的质控,样品分析和现场监测的质控,数据的记录处理和管理要求等,最后提出几点建议。  相似文献   

18.
In November 1990, the Silicate Technology Corporation's (STC) proprietary process for treating soil contaminated with toxic semivolatile organic and inorganic contaminants was evaluated in a Superfund Innovative Technology Evaluation (SITE) field demonstration at the Selma Pressure Treating (SPT) wood preserving site in Selma, California. The SPT site was contaminated principally with pentachlorophenol (PCP) and arsenic, as well as lesser amounts of chromium and copper. Because of their importance when selecting a remedy for the site, PCP and arsenic were identified as critical analytes to evaluate the effectiveness of treatment.

Evaluation of STC's treatment process was based on contaminant mobility, measured by numerous leaching tests, and structural integrity of the solidified material, measured by physical, engineering, and morphological tests. An economic analysis was also performed, using cost information supplied by STC and supplemented by information generated during the demonstration.

Conclusions drawn from this SITE demonstration evaluation are: (1) the STC process can chemically stabilize contaminated soils similar to those at the Selma site that contain both semivolatile organic and inorganic contaminants; (2) PCP was successfully treated as demonstrated by total waste analysis; (3) heavy metals such as arsenic can be immobilized successfully based on various leach-test criteria; (4) the short-term physical stability of the treated waste was good, with unconfined compressive strengths (UCS) well above landfill solidification standards; (5) treatment resulted in a volume increase of 59 to 75 percent (68 percent average) and a slight increase in bulk density; and (6) the process is expected to cost approximately $190 to $360 per cubic yard when it is used to treat 15,000 cubic yards of waste similar to that found at the STC demonstration site, assuming that on-site, in-place disposal is performed.  相似文献   

19.
20.
Abstract

A major component of the Southern Oxidants Study (SOS) 1992 Atlanta Intensive was the measurement of atmospheric nonmethane hydrocarbons. Ambient air samples were collected and analyzed by a network of strategically located automated gas chromatography (GC) systems (field systems). In addition, an extensive canister sampling network was deployed. Combined, more than 3000 chromatograms were recorded. The SOS science team targeted for quantitative analysis 56 compounds which may be substantial contributors to ozone formation or used as air mass tracers. A quality assurance program was instituted to ensure that good measurements were being made throughout the network for each target compound. Common, high-quality standards were used throughout the network. The performance of individual field systems was evaluated during the intensive through the analysis of challenge mixtures. This methodology helped to identify and correct analytical problems as they arose.  相似文献   