首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Airborne dust bioaerosols, ammonia and formaldehyde levels were determined inside two different (ventilated and unventilated) wood working shops. Airborne dust was found at mean values of 4.3 and 3.01 mg m(-3). These levels were higher than that recommended by Egyptian environmental law [1 mg m(-3) indoor maximum allowable concentration (MAC) for hard wood]. The highest frequency of aerodynamic size distribution of airborne wood dust was detected at a diametre of 4.9 microm which was recorded during a machining operation. Total viable bacteria were recorded at a mean value of 10(4) colony-forming units (cfu) m(-3), whereas Gram-negative bacteria were found at very low counts (10(1) cfu m(-3)). Fungi levels were recorded at mean values of 10(3) and 10(2) cfu m(-3) in ventilated and unventilated shops, respectively. Penicillium, Aspergillus, Cladosporium and yeast species were dominant isolates. Moreover, actinomycetes were found at a mean value of 10(3) cfu m(-3) at both workshops. Ammonia was detected in relatively low concentrations (mean values of 457 and 623 microg m(-3)), whereas formaldehyde was found in relatively moderate concentrations (mean values of 0.42 and 0.64 ppm).  相似文献   

2.
A temporary renovation activity releases considerably high concentrations of particulate matter, viable and non-viable, into air. These pollutants are a potential contributor to unacceptable indoor air quality (IAQ). Particulate matter and its constituents lead, sulfate, nitrate, chloride, ammonium and fungi as well as fungal spores in air were evaluated in a building during renovation action. Suspended dust was recorded at a mean value of 6.1 mg m(-3) which exceeded the Egyptian limit values for indoor air (0.15 mg m(-3)) and occupational environments (5 mg m(-3)). The highest particle frequency (23%) of aerodynamic diameter (dae) was 1.7 microm. Particulate sulfate (SO(4)(2-)), nitrate (NO(3)(-)), chloride (Cl(-)), ammonium (NH(4)(+)) and lead components of suspended dust averaged 2960, 28, 1350, 100 and 13.3 microg m(-3), respectively. Viable fungi associated with suspended dust and that in air averaged 1.11 x 10(6) colony forming unit per gram (cfu g(-1)) and 92 colony forming unit per plate per hour (cfu p(-1) h(-1)), respectively. Cladosporium(33%), Aspergillus(25.6%), Alternaria(11.2%) and Penicillium(6.6%) were the most frequent fungal genera in air, whereas Aspergillus(56.8%), Penicillium(10.3%) and Eurotium(10.3%) were the most common fungal genera associated with suspended dust. The detection of Aureobasidium, Epicoccum, Exophiala, Paecilomyces, Scopulariopsis, Ulocladium and Trichoderma is an indication of moisture-damaged building materials. Alternaria, Aureobasidium, Cladosporium, Scopulariopsis and Nigrospora have dae > 5 microm whereas Aspergillus, Penicillium and Verticillium have dae < 5 microm which are suited to penetrate deeply into lungs. Particulate matter from the working area infiltrates the occupied zones if precautionary measures are inadequate. This may cause deterioration of IAQ, discomfort and acute health problems. Renovation should be carefully designed and managed, in order to minimize degradation of the indoor and outdoor air quality.  相似文献   

3.
Personal exposures to viable fungi and bacteria were compared with the concentrations being assessed by stationary samplers in home and workplace microenvironments. A random sample of 81 elementary school teachers in eastern Finland performed two 24-hour measurement periods in wintertime. Concentrations and prevalences of viable fungi and bacteria on the collection filters were determined by cultivation method. The geometric mean concentration was 3-12 cfu m(-3) for total viable fungi, 0.6-3.7 cfu m(-3) for Penicillium and mainly under 1 cfu m(-3) for other fungi. The samples with higher fungal concentrations also had higher diversity of fungi than samples with lower concentrations. The total number of fungal genera recovered was 39 for personal, 34 for home and 23 for work samples. The variation in concentration of Penicillium explained even 25-95% of the variations of total fungal concentration in personal exposure, home and workplace environments. There was an association between personal exposure and home concentration of viable fungi and between personal exposure and home and work concentrations of viable bacteria. Personal exposure and home concentrations of fungi were higher in rural areas than in urban areas. Our results also indicate that presence of a certain fungus in a microenvironment does not necessarily mean similar findings in personal exposure samples.  相似文献   

4.
The composition and variability of airborne fungal spores were studied using two complementary sampling methods in an outdoor environment in Kolkata suburb for 2 years, from November 2002 to October 2004. For monitoring the total fungal spore burden in the air, Burkard 7-day volumetric sampler was used, whereas Andersen two-sage viable sampler was used for isolating the cultivable airborne fungi. Among the 37 fungal spore types identified in the air samples, the predominant ones were Cladosporium, unidentified ascospores, unidentified basidiospores, Aspergilli/Penicilli, Nigrospora, Periconia, Chaetomium, Drechslera, Alternaria, Coprinus, Ganoderma, Pithomyces, and rust spores. Only six fungal spore types (Alternaria, Aspergilli/Penicilli, Cladosporium, Curvularia, Drechslera, and Nigrospora) were recovered in common by the two samplers. For Aspergilli/Penicilli, Drechslera, and Nigrospora, the spore concentration was underestimated in the non-viable sampling method (Burkard sampler). In general, higher spore count was recorded in winter. The highest fungal species variability was observed in early monsoon (June). Relative humidity could significantly predict the seasonal periodicity of the maximum number of airborne spores. The total airborne fungi concentration recorded in the study (15-16?×?10(3) spores m(-3) of air) was lower than the proposed threshold limit value for clinical significance, suggesting apparently no or less airborne-fungi-exposure-related health risk in the sampling area. Cladosporium cladosporioides was recorded beyond the proposed threshold limit value in January 2003 and March 2004; Aspergillus fumigatus and Aspergillus nidulans in winter that might have posed considerable health risk to sensitized individuals.  相似文献   

5.
Exposure to microorganisms can cause various diseases or exacerbate the excitatory responses, inflammation, dry cough and shortness of breath, reduced lung function, chronic obstructive pulmonary disease, and allergic response or allergic immune. The aim of the present study was to investigate the density of microorganisms around the air of processing facilities of a biocomposting plant. Each experiment was carried out according to ASTM E884-82 (2001) method. The samples were collected from inhaled air in four locations of the plant, which had a high traffic of workers and employees, including screen, conveyor belt, aerated compost pile, and static compost pile. The sampling was repeated five times for each location selected. The wind speed and its direction were measured using an anemometer. Temperature and humidity were also recorded at the time of sampling. The multistage impactor used for sampling was equipped with a solidified medium (agar) and a pump (with a flow rate of 28.3 l/m) for passing air through the media. It was found that the mean density of total bacteria was >1.7 × 103 cfu/m3 in the study area. Moreover, the mean densities of fungi, intestinal bacteria (Klebsiella), and Staphylococcus aureus were 5.9 × 103, 3.3 × 103, and 4.1 × 103 cfu/m3, respectively. In conclusion, according to the findings, the density of bacteria and fungi per cubic meter of air in the samples collected around the processing facilities of the biocomposting plant in Sanandaj City was higher than the microbial standard for inhaled air.  相似文献   

6.
Cladosporium is one of the most common airborne molds found in indoor and outdoor environments. Cladosporium spores are important aeroallergens, and prolonged exposure to elevated spore concentrations can provoke chronic allergy and asthma. To accurately quantify the levels of Cladosporium in indoor and outdoor environments, two real-time PCR systems were developed in this study. The two real-time PCR systems are highly specific and sensitive for Cladosporium detection even in a high background of other fungal DNAs. These methods were employed to quantify Cladosporium in aerosols of five different indoor environments. The investigation revealed a high spore concentration of Cladosporium (10(7) m(-3)) in a cow barn that accounted for 28-44% of the airborne fungal propagules. In a countryside house that uses firewood for heating and in a paper and pulp factory, Cladosporium was detected at 10(4) spores m(-3), which accounted for 2-6% of the fungal propagules in the aerosols. The concentrations of Cladosporium in these three indoor environments far exceeded the medical borderline level (3000 spores m(-3)). In a power station and a fruit and vegetable storage, Cladosporium was found to be a minor component in the aerosols, accounted for 0.01-0.1% of the total fungal propagules. These results showed that monitoring Cladosporium in indoor environments is more important than in outdoor environments from the public health point of view. Cladosporium may not be the dominant fungi in some indoor environments, but its concentration could still be exceeding the threshold value for clinical significance. The methods developed in this study could facilitate accurate detection and quantification of Cladosporium for public health related risk assessment.  相似文献   

7.
This on-site survey study was performed to determine the concentrations and emissions of aerial contaminants in the different types of swine houses in Korea and then to present beneficial information available for Korean pig producers to manage optimal air quality in swine house. The swine houses investigated in this research were selected based on three criteria; manure removal system, ventilation mode and growth stage of swine. Mean concentrations of aerial pollutants in swine houses were 8 ppm for ammonia, 300 ppb for hydrogen sulfide, 2 mg m−3 for total dust, 0.6 mg m−3 for respirable dust, 4 log(cfu m−3) for total airborne bacteria and 3 log(cfu m−3) for total airborne fungi, respectively. Mean emissions based on pig (liveweight; 75 kg) and area (m2) were 250 and 340 mg h−1 for ammonia, 40 and 50 mg h−1 for hydrogen sulfide, 40 and 50 mg h−1 for total dust, 10 and 15 mg h−1 for respirable dust, 1.0 and 1.3 log(cfu) h−1 for total airborne bacteria and 0.7 and 1.0 log(cfu) h−1 for total airborne fungi, respectively. In general concentrations and emissions of gases were relatively higher in the swine houses managed with deep-pit manure system with slats and mechanical ventilation mode than the different swine housing types whereas those of particulates and bioaerosol were highest in the naturally ventilated swine houses with deep-litter bed system.  相似文献   

8.
The impact of Attenda abattoir, Ogbomoso southwestern Nigeria on four water sources was investigated using geoelectrical imaging and microbiological analysis. 2D electrical resistivity imaging indicated groundwater contamination by leachate from the abattoir. Electrical resistivity values measured by the traverse run directly on the waste dump and other areas impacted by the waste from the abattoir are generally very low (6.68-16.7 ?m) in comparison to other positions (135-288 ?m). The total viable bacteria count of the water samples ranged from 0.49 × 10(6) to 2.85 × 10(8) cfu/ml and all samples are contaminated with coliforms with the most probable number (MPN)/100 ml ranging from 110 to ≥ 1,600 MPN/100 ml. Among bacteria isolated from the study site (n = 95), resistance to eight antibiotics ranged from 35.8% to 94%. In addition, 85% of Streptococcus agalactiae (n = 31) and Staphylococci (n = 9) showed haemolytic activity while 92% of all isolates showed β-lactamase activity. These results suggest that operations of the abattoir may impact negatively on surrounding aquatic ecosystem and endanger the health of surrounding residents who use water from the wells for domestic purposes. Furthermore, such aquatic ecosystems may serve as reservoir of antibiotic resistant bacteria.  相似文献   

9.
Motor vehicles constitute a significant source of polycyclic aromatic hydrocarbon (PAH) emissions to the atmosphere. Particle-phase priority pollutant PAH concentrations and total suspended particle mass (TSP) were measured in the Lapa bus station and the Americo Simas Tunnel, located in the city of Salvador, Brazil. Separate samples were collected at the bus station at different times of the day, including rush- and non-rush-hour periods. The highest concentrations for nearly all 16 priority PAHs measured at the bus station were observed at 18:30 h, with chrysene showing the highest mean value (26.6 ng m-3). The highest average PAH concentrations measured in the tunnel were observed for pyrene (79.4 +/- 11.5 ng m-3) followed by fluoranthene (39.0 +/- 5.2 ng m-3) and chrysene (28.0 +/- 4.17 ng m-3). TSP levels reached 423 micrograms m-3 in the bus station, and values as high as 2 mg m-3 in the tunnel. The measured Salvador tunnel PAH profiles are very similar to the Salvador bus station profiles, and are similar to PAH profiles reported for the Kojouike Tunnel, located in Kurashiki City, Japan, and the Caldecott Tunnel, located in Berkeley, California.  相似文献   

10.
Bioaerosol concentrations were investigated in a totally indoor composting facility processing fermentable household and green wastes to assess their variability. Stationary samples were collected by filtration close to specific composting operations and then were analysed for cultivable mesophilic bacteria, thermophilic bacteria, mesophilic fungi, thermophilic fungi, endotoxins and total airborne bacteria (DAPI-staining). Indoor concentrations exceeded the background levels, between 500 and 5400 EU m(-3) for endotoxins, 10(4) and 10(6) CFU m(-3) for cultivable bacteria and generally below 10(5) CFU m(-3) for airborne cultivable fungi. No significant (p > 0.05) differences were observed between the indoor composting operations. Successive 30 minute bioaerosol samples were collected to investigate the variation of cultivable mesophilic microorganisms over the work shift. Concentrations of mesophilic bacteria and fungi varied up to 1 log unit depending on the time at which they were collected in the day. Total airborne particles, counted using an optical particle counter, were present at up to 10(8) particles m(-3) and several concentration peaks were noted. Values for total airborne bacteria were roughly 70-fold higher than cultivable bacteria. These results raise the question of the sampling strategy (duration of sampling; number of samples to be collected) used in similar studies. They provide new bioaerosol concentration data in a composting facility and suggest that the filtration sampling method might be a useful tool for exposure measurements in that occupational environment.  相似文献   

11.
The purpose of this study was to compare tanker drivers' occupational exposure level before and after the installation of vapour recovery facilities at 14 service stations. Road tanker drivers are exposed when handling volatile petrol liquid in bulk in the distribution chain. The drivers' exposure was studied during the unloading operation as the bulk petrol flowed into underground storage tanks, displacing vapours in the tank space and causing emission to the environment and the drivers' work area. The exposures were measured again when the dual point Stage I vapour recovery systems were installed for recycling vapours. Short-term measurements were carried out in the drivers' breathing zones by drawing polluted air through a charcoal tube during unloading. The samples were analysed in the laboratory by gas chromatography for C3-C11 aliphatic hydrocarbons, tert-butyl methyl ether (MTBE), tert-amyl methyl ether (MTAE), benzene, toluene and xylene. The road tanker loads delivered consisted of oxygenated and reformulated petrol (E95 and E98 brands), which contained on average 13% oxygenates. Before the installation of the vapour recovery system, the geometric mean (GM) concentration of aliphatic hydrocarbons was 65 mg m-3 (range 6-645 mg m-3) in the drivers' breathing zones. After the installation at the same service stations, the corresponding exposure level was 8.3 mg m-3 (range < 1-79 mg m-3). The GM of the MTBE concentrations was 8.6 mg m-3 (range 1-67 mg m-3) without vapour recovery and 1.5 mg m-3 (range < 0.1-10 mg m-3) with vapour recovery. The differences between the aliphatic hydrocarbons and the MTBE exposure levels during the unloading of the road tankers without and with vapour recovery were statistically significant (p < 0.05).  相似文献   

12.
Bioaerosols are a type of suspended sediments that contribute to poor air quality in Taiwan. Bioaerosols include allergens such as: fungi, bacteria, actinomycetes, arthropods and protozoa, as well as microbial products such as mycotoxins, endotoxins and glucans. When allergens and microbial products are suspended in the air, local air quality will be influenced adversely. In addition, when the particle size is small enough to pass through the respiratory tract entering the human body, the health of the local population is also threatened. Therefore, the purpose of this study is to attempt to understand the concentration and types of bacteria and the bacteria numbers for various particle size ranges during a study period of June 2005 to February 2006 in Taichung City, Central Taiwan. The results indicate that the total average bacterial concentration by using NA medium incubated for 48 h were 8.0 × 102, 1.4 × 103, 2.4 × 103 and 1.3 × 103, 1.9 × 103, 3.5 × 103 cfu/m3 for CMES, TRIPS and RFS sampling sites during the daytime and nighttime period of June 2005 to February 2006. Moreover, the total average bacterial concentration by using R2A medium incubated for 48 h were 8.5 × 102, 1.5 × 103, 2.2 × 103 and 1.2 × 103, 1.7 × 103, 2.5 × 103 cfu/m3 for CMES, TRIPS and RFS sampling sites the daytime and nighttime during the same sampling period. The total average bacteria concentration was the same in either NA or R2A medium for the same sampling times or sites. The total average bacterial concentration was higher in daytime period than that of nighttime period for CMES, TRIPS and RFS sampling sites. The high average bacterial concentration was found in the particle size range of 0.53–0.71 mm (average bioaerosol size was in the range of 2.1–4.7 μm) for each sampling site. Also, 20 kinds of bacteria exceeded levels for each sampling site and were classified as according to shape: rod, coccus and filamentous.  相似文献   

13.
This study was primarily aimed at investigating the physicochemical and microbial quality of water in 14 such dugouts from five districts in the northern region of Ghana. Results obtained suggest that except for colour, turbidity, total iron and manganese, many physicochemical parameters were either within or close to the World Health Organisation’s acceptable limits for drinking water. Generally, colour ranged from 5 to 750 Hz (mean 175 Hz), turbidity from 0.65 to 568 nephelometric turbidity units (NTU; mean 87.9 NTU), total iron from 0.07 to 7.85 mg/L (mean 1.0 mg/L) and manganese from 0.03 to 1.59 mg/L (mean 0.50 mg/L). Coliform counts in water from all the dugouts in both wet and dry seasons were, however, above the recommended limits for drinking water. Total and faecal coliforms ranged from 125 to 68,000 colony forming units (cfu)/100 mL (mean 10,623 cfu/100 mL) and <?1 to 19,000 cfu/100 mL (mean 1,310 cfu /100 mL), respectively. The poor microbial quality, as indicated by the analytically significant presence of coliform bacteria in all samples of dugout water, strongly suggests susceptibility and exposure to waterborne diseases of, and consequent health implications on, the many people who continuously patronise these vital water resources throughout the year. In particular, more proactive sustainable water management options, such as introduction to communities of simple but cost-effective purification techniques for water drawn from dugouts for drinking purposes, education and information dissemination to the water users to ensure environmentally hygienic practices around dugouts, may be needed.  相似文献   

14.
Mass Concentration of ambient particulate matter with an aerodynamic diameter less than 10µm (PM10) are reported for the first time for a range of sites in Dublin City over a 6 month period from January 1st 1996 to June 30th 1996. PM10 gravimetric mass concentration measurements are made with low flow Partisol 2000 air samplers using an impaction type PM10 inlet and 47mm diameter glass fibre filters. In addition, much finer time resolution measurements (minimum sampling frequency of 30 minutes) are made using a tapered element oscillating microbalance (TEOM) PM10 mass monitor. These PM10 mass concentrations methods are also compared with mass concentration inferred using the standard black smoke method. Analysis of the ambient mass concentration data with reference to traffic density and meteorological influences are presented. Results for the first six months of 1996 show that the average PM10 values range from a high of 49 µg m-3 at the Dublin city centre site to 14 µg m-3 at one of the suburban sites. Intercomparison between PM10 and black smoke mass concentrations show that the relationship is site specific. Statistical analysis between PM10 levels and car traffic number show a positive correlation while a weak negative correlation is found between PM10 levels and rainfall amount, wind speed and air temperature.  相似文献   

15.
于2006年4-6月在红沙港海域进行了四个航次调查,对海域中5个站位的海水样品进行了细菌学检测.结果表明,四个航次海水粪大肠杆菌群超标率最高为40%,异养细菌总数超标率均达60%以上.四个航次海水粪大肠杆菌单项污染指数平均值分别为0.755、1.792、2.215和0.578,异养细菌总数单项污染指数平均值分别为1.54、2.73、24.04和6.11.生物统计学分析显示,粪大肠杆菌群与异养细菌总数存在一定的正相关关系,其相关系数r2=0.439 9.红沙港海水已受到粪大肠杆菌和异氧细菌污染.  相似文献   

16.
对装有空气污染控制系统的垃圾压缩车同普通垃圾压缩车进行了实验比较,结果表明,前者收集垃圾时生物气溶胶的暴露减少:总尘量减少了约2/3(α=3%);内毒素减少了约2/3(α=10%);总微生物减少了约6/7(α=9%);活菌减少了约3/4(α=15%);活真菌减少了约4/5(α=1%)。垃圾压缩车收集垃圾时生物气溶胶暴露可通过在覆盖于压缩车垃圾斗处塑料薄板帘后安装的排风设备减少。  相似文献   

17.
Hourly concentrations of ozone (O(3)), 55 volatile organic compounds (VOCs, ozone precursors) and nitrogen oxides (NOx) were measured at an upwind urban site, a downwind suburban site, and a rural site in central Taiwan, from January 2003 to December 2006. VOC and NOx mean concentrations showed a gradient from high to low across the urban (56 ppb and 34 ppb), suburban (38 ppb and 27 ppb) and rural sites (25 ppb and 21 ppb) but a reverse gradient in ozone across these sites (24, 27, and 29 ppb, respectively). Although there was about twice the difference in VOC concentrations between the urban and rural sites, nearly 65% ozone formation potential was contributed to by the same 9 VOCs. Seasonal patterns showed peak ozone levels in autumn and minima in summer at the urban site, but minima in winter at the downwind suburban and rural sites. Ozone precursor levels, on the other hand, were lowest in summer and highest in winter. The diurnal pattern showed that ozone levels peaked one hour later at the rural site than at the urban site. The ethylbenzene to m,p-xylene ratio, an indicator of the age of the air mass, increased from 0.4 at the urban site to 0.6 at the suburban site and 0.8 at the rural site during daily peak ozone times. This finding suggests the transport of ozone and precursors from upwind to downwind producing elevated ozone levels in the suburban and rural areas. Ozone episodes occurred mostly in days with a mean midday UV index of 6.5 (1 UV index=100 J m(-2)) and wind speed at 1.3 m s(-1) at all three sites.  相似文献   

18.
以西安城市表层土壤和地表灰尘为研究对象,分析其基本理化指标。结果表明,西安市表层土壤pH值的变化范围是7.65~8.54,属弱碱性。地表灰尘pH值的变化范围是6.59~11.19,属碱性。表层土壤的低频磁化率和高频磁化率均值分别为1.55×10^-6 m^3/kg和1.46×10^-6 m^3/kg,频率磁化率均值为6.7%。地表灰尘的低频磁化率和高频磁化率均值分别为5.50×10^-6 m^3/kg和4.84×10^-6 m^3/kg,频率磁化率均值为1.88%。表层土壤和地表灰尘中总有机碳均值分别为1.31%和3.97%。西安城市表层土壤和地表灰尘均主要以粉粒为主,且二者各理化性质之间均有一定的相关性。  相似文献   

19.
The long-term behaviour of (137)Cs activity concentrations in air and fallout has been studied in the city of Zagreb for the post-Chernobyl period (1986-2006) as a part of an extended monitoring program of radioactive contamination of human environment in Croatia. Annual mean (137)Cs activity concentrations in air and annual total deposition fluxes (wet plus dry) decreased from 2.8 x 10(-4) Bq m(-3) in September 1986 to 3.0 x 10(-6) Bq m(-3) in last quarter of 2006 and from 6,410 Bq m(-2) year(-1) in 1986 to 2 Bq m(-2) year(-1) in 2006 respectively. By fitting the measured (137)Cs activity concentrations to the theoretical curve the ecological half-lives of (137)Cs in air and fallout were estimated with respective values of 0.46 and 0.54 years for immediate post-Chernobyl period, increasing to 5.52 and 3.97 years afterwards. Using the data on (137)Cs activity concentrations in air and fallout total caesium deposition velocity of (3.34 +/- 3.13) x 10(-2) ms(-1) was estimated with median value being 2.13 x 10(-2) ms(-1). Such relatively high (137)Cs deposition velocities compared with pre-Chernobyl ones, are characteristic for the post-Chernobyl period and, according to Stokes' settling law, indicate that the diameters of aerosol particles associated with (137)Cs originated from the Chernobyl accident are pretty large, i.e. >1 microm. (134)Cs/(137)Cs activity ratio in fallout and in air has been found to be similar to the theoretically predicted values, initial value being about 0.5 and decreasing according to differential radioactive decay. The similar ratio has been observed in most of the other environmental samples.  相似文献   

20.
The Po valley in northern Italy is renowned for its high air pollutant concentrations. Measurements of air pollutants from a background site in Modena, a town of 200 thousand inhabitants within the Po valley, are analysed. These comprise hourly data for CO, NO, NO(2), NO(x), and O(3), and daily gravimetric equivalent data for PM(10) from 1998-2010. The data are analysed in terms of long-term trends, annual, weekly and diurnal cycles, and auto-correlation and cross-correlation functions. CO, NO and NO(2) exhibit a strongly traffic-related pattern, with daily peaks at morning and evening rush hour and lower concentrations over the weekend. Ozone shows an annual cycle with a peak in July due to local production; notwithstanding the diurnal cycle dominated by titration by nitrogen oxide, the decreasing long term trend in NO concentration did not affect the long term trend in O(3), whose mean concentration remained steady over the sampling period. PM(10) shows a strong seasonality with higher concentration in winter and lower concentration in summer and spring. Both PM(10) and ozone show a marked weekly cycle in summer and winter respectively. Regressions of PM(10) upon NO(x) show a consistently greater intercept in winter, representing higher secondary PM(10) in the cooler months of the year. There is a seasonal pattern in primary PM(10) to NO(x) ratios, with lower values in winter and higher values in summer, but the reasons are unclear.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏