首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 812 毫秒
1.
The effects of the organic loading rate (OLR) on the performance and the granular sludge characteristics of an expanded granular sludge bed (EGSB) reactor used for treating real traditional Chinese medicine (TCM) wastewater were investigated. Over 90 % of the COD removal by the EGSB reactor was observed at the OLRs of 4 to 13 kg COD/(m3 day). However, increasing the OLR to 20 kg COD/(m3 day) by reducing the hydraulic retention time (HRT 6 h) reduced the COD removal efficiency to 78 %. The volatile fatty acid (VFA) concentration was 512.22 mg/L, resulting in an accumulation of VFAs, and propionic acid was the main acidification product, accounting for 66.51 % of the total VFAs. When the OLR increased from 10 to 20 kg COD/(m3 day), the average size of the granule sludge decreased from 469 to 258 μm. There was an obvious reduction in the concentration of Ca2+ and Mg2+ in the granular sludge. The visible humic acid-like peak was identified in the three-dimensional excitation-emission matrix (EEM) fluorescence spectra of the soluble microbial products (SMPs). The fatty acid bond, amide II bond, amide III bond, and C–H bond bending were also observed in the Fourier transform infrared (FTIR) spectra of the SMPs. Methanobacterium formicicum, Methanococcus, and Bacteria populations exhibited significant shifts, and these changes were accompanied by an increase in VFA production. The results indicated that a short HRT and high OLR in the EGSB reactor caused the accumulation of polysaccharides, protein, and VFAs, thereby inhibiting the activity of methanogenic bacteria and causing granular sludge corruption.  相似文献   

2.
The presence of a high concentration of sodium in wastewater is considered inhibitory for anaerobic biological treatment. This research was designed to investigate the potential use of halophilic methanogens and a mixed culture of halophilic methanogens and digester sludge, in anaerobic filters, for treatment of organic pollutants in high-saline wastewater at 35 degrees C. Data related to startup of the filters are presented. Both halophilic and mixed-culture anaerobic filters were able to operate at a sodium chloride concentration of 35 g/L, at organic loading rates (OLRs) of 6.2 and 5 kg chemical oxygen demand (COD)/m(3) x d, respectively. The COD removal efficiency was as high as 80%, and the systems were able to maintain a low volatile fatty acids concentration of 500 mg/L. No significant difference in COD removal was observed between the halophilic filter and the mixed-culture filter. Increasing the salt concentration to 37 g/L at an OLR of 3 kg/m(3) x d caused system failure.  相似文献   

3.
采用膨胀颗粒污泥床(EGSB)反应器对城市生活垃圾焚烧厂产生的垃圾沥滤液进行处理。实验结果表明:中温条件下,当COD浓度为55 000 mg/L左右,有机容积负荷(OLR)为22.8 kg COD/(m3.d)时,EGSB对垃圾沥滤液具有较好的的处理效果,COD去除率可达94.2%。当进水COD为72 000 mg/L左右时,为保证反应器的稳定运行,OLR应降低至18.2 kg COD/(m3.d),此时COD去除率可以达到88%左右,出水COD平均为9 103 mg/L。垃圾沥滤液和EGSB处理出水均以小分子量有机物为主,其中<4 kDa的有机物分别占76.5%和74.4%。EGSB对整个分子量区间的溶解性有机物都有较好的处理效果,其中对大分子有机物的处理效率相对更高。  相似文献   

4.
Simultaneous nitrification-denitrification (SND) of municipal wastewater was investigated in a laboratory-scale membrane bioreactor (MBR) operated at two different hydraulic retention times (HRTs), 0.5 and 1 day, dissolved oxygen 3.0 to 0.5 mg/L, and solids retention time (SRT) between 28 and 120 days. The organic loading rate (OLR) (0.11 to 0.64 kg chemical oxygen demand [COD]/m3/d) and influent soluble COD (SCOD)/ total Kjeldahl nitrogen (TKN) ratio (5 to 19) were varied by the addition of glucose. The ammonia-nitrogen and TKN removals were over 97%, and total nitrogen removal was approximately 89% in the MBR. The maximum specific nitrification rates (98 mg N/d/g VSS) and specific denitrification rates (81 mg N/d/g VSS) occurred at an SCOD/TKN ratio of 9.1. The optimum conditions for maximum total nitrogen removal by SND in a single reactor MBR have been found to be low dissolved oxygen (< 0.6 mg/L) and high OLR (approximately 0.64 kg COD/m3/d) at an HRT of 0.5 day and SRT of approximately 85 days.  相似文献   

5.

This article presents a review of anaerobic treatment technologies to treat slaughterhouse wastewater including its advantages and disadvantages. Physico-chemical characteristics and biochemical methane potential (BMP) of slaughterhouse wastewater are addressed. Various anaerobic treatment technologies are presented with the related operating parameters, viz., hydraulic retention time (HRT), organic loading rate (OLR), upflow velocity (Vup), and biogas yield vis-a-vis treatment efficiency in terms of chemical oxygen demand (COD). In addition, various factors that affect the anaerobic treatment of slaughterhouse wastewater such as high oil & grease (O & G) concentration in influent, inhibitors, volatile fatty acids (VFAs), and the loading rate are also addressed. The literature review indicated that the slaughterhouse wastewater can be treated effectively by employing any anaerobic treatment technologies at OLRs up to 5 kg COD/m3.d with more than 80% COD removal efficiency without experiencing operational problems. Anaerobic hybrid reactors (AHRs) were found the most effective among various reviewed technologies because of their ability to operate at higher OLRs (8 to 20 kg COD/m3.d) and lower HRTs (8 to 12 hrs).

  相似文献   

6.
Chowdhury N  Nakhla G  Zhu J 《Chemosphere》2008,71(5):807-815
A novel liquid-solid circulating fluidized bed bioreactor (LSCFB) configured with anoxic and aerobic columns and lava rock as the biofilm carrier was used to treat synthetic municipal wastewater. Four different empty bed contact times (EBCTs) of 0.82, 0.65, 0.55, and 0.44 h were examined to optimize nutrient removal capability of the system. The LSCFB demonstrated tertiary effluent quality organic and nitrogen removal efficiencies. Effluent characteristics of the LSCFB were soluble biological oxygen demand (SBOD)10 mg l(-1) and total nitrogen (TN)<10 mg l(-1) at organic loading rate (OLR) of 5.3 kg m(-3)d(-1) and nitrogen loading rate of 0.54 kg Nm(-3)d(-1). Remarkably low yields of 0.14, 0.17, 0.19, and 0.21 g VSS g(-1)COD were observed at OLR of 2.6, 3.2, 4.1 and 5.3 kg COD m(-3)d(-1), where increment of biomass growth and detachment rate were also experienced with increasing OLR. However the system demonstrated only 30% phosphorus removal, and mass balances along the anoxic and aerobic columns showed biological phosphorus removal in the system. Organic mass balance showed that approximately 40% of the influent COD was utilized in the anoxic column and the remaining COD was oxidized in the aerobic column. The system is very efficient in nitrification-denitrification, with more than 90% nitrification of ammonium and overall nitrogen removal in the LSCFB was 70+/-11% even at an EBCT of 0.44 h.  相似文献   

7.
在中温(35±1℃)条件下,以新型橡胶颗粒为载体的厌氧流化床(AFB)反应器处理模拟味精废水为研究体系,考察有机负荷(OLR)由2.08 kg/(m3.d)提高到19.20 kg/(m3.d)期间,污染物去除率、胞外聚合物(EPS)含量及其在生物膜和混合液中的分布、生物膜中MLVSS含量及脱氢酶活性等的变化情况。结果表明,随有机负荷增加,污染物去除稳定,COD去除率维持在80%左右;EPS在生物膜中的量大于在混合液中的量,并以蛋白质为主要成分,但其总量呈递减趋势;当有机负荷为19.20 kg/(m3.d)时,生物膜中MLVSS含量约为23.1 mg/g载体,脱氢酶活性则为22.6 mg/(L.h);载体生物膜的生物相以独缩虫属、聚缩虫属、累枝虫属和钟虫等为主。  相似文献   

8.
通过自主设计的多级厌氧反应器系统来考察半连续处理螺旋霉素工业发酵菌渣的效果。该系统总反应体积为44L,由4个11L的升流式厌氧反应罐组成,罐体间采用串联方式连接。121d的连续运行周期分为3个阶段,各阶段的有机负荷率分别为1.27、1.82和2.73kgCOD/(m3·d)。全过程中主要监测了各级罐体的产气量和螺旋霉素的降解。结果表明,多级厌氧反应器系统启动初期会出现产气不稳定现象,经过2个月的运行之后系统达到稳定状态。在有机负荷达到2.73kgCOD/(m3·d)时,各级罐体仍能稳定运行,总产气的45%集中在1号罐。在系统启动初期,螺旋霉素不能被明显降解。运行约80d后,整个体系达到了快速降解螺旋霉素的状态,在2.73kgCOD/(m3·d)的有机负荷率下,螺旋霉素降解率达到97%,同时可溶性COD降解率也达到了90%。  相似文献   

9.
采用两级SBR工艺(TSSBR)处理COD与氮浓度较高的工业废水,SBR1去除有机物,SBR2主要进行硝化反硝化。TSSBR与传统SBR工艺相比,COD降解速率和硝化反应速率明显提高,COD去除率由84%提高到93%,2种工艺的反硝化速率没有明显差别。在原水COD浓度较高的情况下,TSSBR可有效克服高COD浓度对硝化反应的抑制,硝化反应速率是传统SBR的2倍。对于COD和氮浓度较高的工业废水,TSSBR明显优于传统SBR,是一种理想的处理工艺。  相似文献   

10.
低温环境下内置腐殖土填料SBR系统处理糠醛废水   总被引:1,自引:0,他引:1  
在水温为5~10℃左右的条件下,通过实验对比了传统SBR系统与内置腐殖土填料式SBR系统处理糠醛废水的效能,结果表明:由于内置腐殖土填料的作用,填料式SBR系统的去除效能要高于未装填料的SBR系统;传统SBR系统的COD、氨氮和总氮的去除率分别为89%、85%和59%,出水浊度为8.6 NTU;填料式SBR系统的COD、氨氮和总氮的去除率分别为95%、90%和71%,出水浊度为1.7 NTU。  相似文献   

11.
两级SBR与传统SBR工艺的对比研究   总被引:2,自引:0,他引:2  
用两级SBR工艺(TSSBR)处理COD与氮浓度较高的工业废水,SBR1去除有机物,SBR2主要进行硝化反硝化。TSSBR与传统SBR工艺相比,COD降解速率和硝化反应速率明显提高,COD去除率由84%提高到93%,2种工艺的反硝化速率没有明显差别。在原水COD浓度较高的情况下,TSSBR可有效克服高COD浓度对硝化反应的抑制,硝化反应速率是传统SBR的2倍。对于COD和氮浓度较高的工业废水,TSSBR明显优于传统SBR,是一种理想的处理工艺。  相似文献   

12.
Columnar packed-bed (PB) reactors with a specific surface area of 127 m2/m3 were investigated in this study for treating nitrate wastewater. This study demonstrated that a single-stage packed bed was able to achieve total nitrogen (TN) and chemical oxygen demand (COD) removal efficiencies higher than 83 and 75%, respectively. The highest achievable TN and COD removal rates were 47.2 g N/m2 x d and 158.0 g COD/m2 x d, respectively. The substrate removal rate in the PB column was found to follow half-order reaction kinetics, with a reaction coefficient, kappa, of 53.62 (mg/L)1/2/d. A dual-stage PB system was capable of achieving TN and COD removal efficiencies greater than 99 and 98%, respectively. Effluent TN and COD concentrations less than 6.5 mg NO3(-)-N/L and 50.0 mg COD/L, respectively, were obtained when the dual PB system was used.  相似文献   

13.
BACKGROUND: Dye wastewater is one of the main pollution sources of water bodies in China. Conventional biological processes are relatively ineffective for color removal, the development of alternative treatment methods will become important. Our subjective was that of introducing a new biotreatment technology which combined a facultative biofilm reactor (FBR) with an aerobic reactor (AR) to treat a dye wastewater. The efficiencies of color and chemical oxygen demand (COD) removal and the mechanism of dye degradation were investigated. METHODS: The anthraquinone acid dye (acid blue BRLL) concentration, organic loading rate (OLR) and hydraulic retention time (HRT) were varied in the experiments to evaluate the treatment efficiency and process stability. The biodegradation products were detected by infrared (IR) and high performance liquid chromatography and mass spectrometry (HPLC-MS). RESULTS AND DISCUSSION: The results demonstrated that the facultative biofilm process was more effective for decolorization than the anaerobic stage of an anaerobic-aerobic process. Most color removal occurred in the facultative reaction (maximum to 88.5%) and the BOD (biochemical oxygen demand): COD of the FBR effluent increased by 82.2%, thus improving the biodegradability of dyes for further aerobic treatment. The dye concentration, OLR and HRT will be the factors affecting decolorization. Color removal efficiency falls as the influent dye concentration increases, but rises with increased HRT. The infrared and HPLC-MS analyses of the effluents of FBR and AR reveal that the dye parent compound was degraded in each reactor during the process. CONCLUSION: The Facultative-aerobic (F-A) system can effectively remove both color and COD from the dye wastewater. The FBR played an essential role in the process. The average overall color and COD in the system were removed by more than 93.9% and 97.1%, respectively, at an OLR of 1.1 kg COD m(-3) d(-1) and at the HRT of 18-20 hours in the FBR and 4-5 hours in the AR. The color removal mechanism in each reactor was not only a sort of biosorption on the floc materials, but even more an effect of biodegradation, especially in the facultative process. Recommendation and Outlook. In applying the F-A system to treat a dye wastewater, the control of facultative processes and the set up of appropriate operation conditions appear to be critical factors. Also, it is suggested a moderate COD loading rate and about a 24-hour HRT will favor the F-A system.  相似文献   

14.
An upflow anaerobic sludge blanket (UASB)-anoxicaerobic system was used for treatment of tomato and bean processing wastewater. At various hydraulic retention times, ranging from 0.7 to 5 days, excellent removal of chemical oxygen demand (COD), biochemical oxygen demand (BOD), total suspended solids (TSS), ammonia-nitrogen (NH4-N), and total Kjeldahl nitrogen was achieved with final effluent BOD/TSS/NH4N concentrations of less than 15/15/1 mg/L. Biogas yield in the UASB reactor varied from 0.33 to 0.44 m3/kgCODremoved. The kinetics of anaerobic treatment were investigated. The yield coefficient was 0.03 gVSS/gCOD; maximum specific growth rate was 0.24 day(-1); Monod half velocity constant was 135 mgCOD/L; and specific substrate utilization rate was 3.25 gCOD/gVSS x d. Nitrification and denitrification kinetics were studied in batch experiments, and the rates were comparable with those in the continuous flow system.  相似文献   

15.
好氧颗粒污泥的培养及处理味精废水   总被引:1,自引:1,他引:0  
于鲁冀  何青  王震 《环境工程学报》2012,6(6):1929-1935
以厌氧颗粒污泥为接种污泥,在模拟废水条件下利用SBR 35 d成功培养出了具有同步硝化反硝化作用的好氧颗粒污泥,反应器对COD和NH4+-N去除率分别高于95%和99%。将该反应器用于处理味精废水,当COD、NH4+-N的容积负荷分别为2.4 kg/(m3.d)、0.24 kg/(m3.d)时,COD、NH4+-N和TN去除率分别高于90%、99%和85%。处理味精废水后的颗粒污泥粒径由之前的0.8~2.5 mm减小至0.6~1.8 mm,颗粒结构较之前更加密实。  相似文献   

16.
采用厌氧流化床(AFB)-序批式反应器(SBR)工艺处理蓝皮制革工业废水。分别考察了水力停留时间(HRT)、容积负荷对厌氧流化床以及曝气时间、污泥浓度、溶解氧浓度对SBR反应器处理效果的影响。试验结果表明,AFB将实验废水的BOD_5/COD(B/C)值由0.19~0.26提高至0.35~0.42,有效提高了其可生化性;在进水COD浓度为1 700~1 890 mg/L、HRT为1 d、容积负荷为1.792 kg COD/(m~3·d)时,COD去除率达65.2%~68.5%,且具有良好的抗冲击负荷能力。SBR在进水COD浓度为628~712 mg/L、污泥浓度为2.9 g/L、曝气时间为10 h、溶解氧浓度为2 mg/L工况下,COD去除率达87.6%,NH_3-N去除率达93.6%,处理后出水水质符合污水综合排放标准(GB 8978-1996)中的一级标准要求。  相似文献   

17.

Performance and microbial community composition were evaluated in a two-phase anaerobic and aerobic system treating sulfate-rich cellulosic ethanol wastewater (CEW). The system was operated at five different chemical oxygen demand (COD)/SO4 2− ratios (63.8, 26.3, 17.8, 13.7, and 10.7). Stable performance was obtained for total COD removal efficiency (94.5%), sulfate removal (89.3%), and methane production rate (11.5 L/day) at an organic loading rate of 32.4 kg COD/(m3·day). The acidogenic reactor made a positive contribution to net VFAs production (2318.1 mg/L) and sulfate removal (60.9%). Acidogenic bacteria (Megasphaera, Parabacteroides, unclassified Ruminococcaceae spp., and Prevotella) and sulfate-reducing bacteria (Butyrivibrio, Megasphaera) were rich in the acidogenic reactor. In the methanogenic reactor, high diversity of microorganisms corresponded with a COD removal contribution of 83.2%. Moreover, methanogens (Methanosaeta) were predominant, suggesting that these organisms played an important role in the acetotrophic methanogenesis pathway. The dominant aerobic bacteria (Truepera) appeared to have been responsible for the COD removal of the SBR. These results indicate that dividing the sulfate reduction process could effectively minimize sulfide toxicity, which is important for the successful operation of system treating sulfate-rich CEW.

  相似文献   

18.
外循环式UASB反应器处理槟榔废水   总被引:1,自引:0,他引:1  
在中温(35±2℃)条件下,利用外循环式UASB反应器处理中高有机浓度的槟榔加工废水,并着重探讨了水力停留时间(HRT)对厌氧消化的影响。研究表明,当反应器稳定运行,水力停留时间为1 d,进水COD浓度5 000 mg/L左右,容积负荷在2.53-5.25 kg COD/(m3·d)时,COD去除率在38%以上,出水COD〈3 000 mg/L,平均产气率为0.41 m3/kg COD;若水力停留时间延长至4 d,容积负荷为1.26-1.30 kg COD/(m3·d),COD去除率可以达到79%,出水COD〈1 200 mg/L,出水可生化性下降,BOD5/COD平均为0.28,实验取得了良好的处理效果,为利用厌氧技术处理槟榔加工废水提供了设计依据。  相似文献   

19.
Trickle-bed air biofilters (TBABs) are suitable for treating volatile organic compounds (VOCs) at a significantly high practical loading because of their controlled environmental conditions. The application of TBAB for treating styrene-contaminated air under periodic backwashing and cyclical nonuse periods at a styrene loading of 0.64-3.17 kg chemical oxygen demand (COD)/m3 x day was the main focus of this study. Consistent long-term efficient performance of TBAB strongly depended on biomass control. A periodic in situ upflow with nutrient solution under media fluidization, that is, backwashing, was approached in this study. Two different nonuse periods were employed to simulate a shutdown for equipment repair or during weekends and holidays. The first is a starvation period without styrene loading, and the second is a stagnant period, which reflects no flow passing through the biofilter. For styrene loadings up to 1.9 kg COD/m3 x day, removal efficiencies consistently above 99% were achieved by conducting a coordinated biomass control strategy, that is, backwashing for 1 hr once per week. Under cyclical nonuse periods for styrene loadings up to 1.27 kg COD/m3 x day, stable long-term performance of the biofilter was maintained at more than 99% removal without employing backwashing. No substantial impact of nonuse periods on the biofilter performance was revealed. However, a coordinated biomass control by backwashing subsequently was unavoidable for attaining consistently high removal efficiency at a styrene loading of 3.17 kg COD/m3 x day. As styrene loading was increased, reacclimation of the biofilter to reach the 99% removal efficiency following backwashing or the nonuse periods was delayed. After the non-use periods, the response of the biofilter was a strong function of the biomass in the bed. No significant difference between the effects of the two different nonuse periods on TBAB performance was observed during the study period.  相似文献   

20.
分别采用水解酸化与好氧(SBR)、厌氧(UASB)与好氧(SBR)工艺对涤纶短纤维废水的生物降解性能进行研究。水解酸化与好氧工艺在进水COD为1 900 mg/L的时候,去除率在80%左右。采用UASB-SBR工艺,进水COD为2700 mg/L时,COD去除率可以达到96%,出水COD〈100 mg/L。实验研究表明,涤纶短纤维废水更适合采用UASB-SBR工艺来处理,并且能够取得较好的效果。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号