首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 328 毫秒
1.
Abstract

A simple, very efficient method is presented for routine analysis of herbicide Krovar I? (active components bromacil and diuron) in water and soil samples. Water samples were extracted by liquid–liquid extraction with dichloromethane (DCM) as extraction solvent. For soil samples two different extraction techniques were compared: microwave-assisted solvent extraction and a shaking technique using a platform shaker. Extracts were analyzed by high performance liquid chromatography using a water:methanol gradient. Liquid chromatography was coupled with atmospheric pressure chemical ionization mass spectrometry (LC-APCI-MS) for quantification of bromacil and diuron. Optimization of the APCI-MS was done by using standards in the flow injection analysis mode (FIA). Method detection limit for liquid samples for bromacil is 0.04 µg L?1 and for diuron 0.03 µg L?1. Method detection limit for soil samples is 0.01 µg g?1 dry weight for both compounds. Results of analysis of field samples of water and soil are also presented.  相似文献   

2.
Four methods were developed for the analysis of fluroxypyr in soil samples from oil palm plantations. The first method involved the extraction of the herbicide with 0.05 M NaOH in methanol followed by purification using acid base partition. The concentrated material was subjected to derivatization and then cleaning process using a florisil column and finally analyzed by gas chromatography (GC) equipped with electron capture detector (ECD). By this method, the recovery of fluroxypyr from the spiked soil ranged from 70 to 104% with the minimum detection limit at 5 microg/kg. The second method involved solid liquid extraction of fluroxypyr using a horizontal shaker followed by quantification using high performance liquid chromatography (HPLC) equipped with UV detector. The recovery of fluroxypyr using this method, ranged from 80 to 120% when the soil was spiked with fluroxypyr at 0.1-0.2 microg/g soil. In the third method, the recovery of fluroxypyr was determined by solid liquid extraction using an ultrasonic bath. The recovery of fluroxypyr at spiking levels of 4-50 microg/L ranged from 88 to 98% with relative standard deviations of 3.0-5.8% with a minimum detection limit of 4 microg/kg. In the fourth method, fluroxypyr was extracted using the solid liquid extraction method followed by the cleaning up step with OASIS HLB (polyvinyl dibenzene). The recovery of fluroxypyr was between 91 and 95% with relative standard deviations of 4.2-6.2%, respectively. The limit of detection in method 4 was further improved to 1 pg/kg. When the weight of soil used was increased 4 fold, the recovery of fluroxypyr at spiking level of 1-50 microg/kg ranged from 82-107% with relative standard deviations of 0.5-4.7%.  相似文献   

3.
The present study describes the application of different solid-phase extraction techniques for the extraction, separation, and quantitative determination of 10 commonly used herbicides with different chemical structures (chlorsulfuron, diuron, bentazone, linuron, chlorpropham, fenoxoprop-ethyl, MCPA, diclofop-methyl, fluazifop-butyl, trifluraline) in water. Octadecyl (C(18)) Empore extraction disks, octadecyl (C(18)), and stryene divinylbenzene (SDB) Bond Elut Env cartridges were compared for solid-phase extraction efficiency. Herbicides were separated and quantified by reversed-phase high performance liquid chromatography with diode-array detection (HPLC-DAD) with simultaneous separation on two columns of differing polarity (C(18) and CN) to confirm identification. Analytical separation was performed simultaneously on C(18) and CN columns. Reanalysis of the sample extracts on a (cyano) CN column were used to confirm the identity of these compounds. Method optimization and validation parameters were presented in this work. Recoveries varied from 76.0% to 99.0% for C(18) disks, from 75.1% to 100.0% for C(18) cartridges, and from 54.0% to 98.0% for SDB cartridges over concentrations at 0.025--0.4 microg L(-1). The limits of detection were 0.012--0.035 microg L(-1).  相似文献   

4.
Tran AT  Hyne RV  Doble P 《Chemosphere》2007,67(5):944-953
The present study describes the application of different extraction techniques for the preconcentration of ten commonly found acidic and non-acidic polar herbicides (2,4-D, atrazine, bensulfuron-methyl, clomazone, dicamba, diuron, MCPA, metolachlor, simazine and triclopyr) in the aqueous environment. Liquid-liquid extraction (LLE) with dichloromethane, solid-phase extraction (SPE) using Oasis HLB cartridges or SBD-XC Empore disks were compared for extraction efficiency of these herbicides in different matrices, especially water samples from contaminated agricultural drainage water containing high concentrations of particulate matter. Herbicides were separated and quantified by high performance liquid chromatography (HPLC) with an ultraviolet detector. SPE using SDB-XC Empore disks was applied to determine target herbicides in the Murrumbidgee Irrigation Area (NSW, Australia) during a two-week survey from October 2005 to November 2005. The daily aqueous concentrations of herbicides from 24-h composite samples detected at two sites increased after run-off from a storm event and were in the range of: 0.1-17.8 microg l(-1), < 0.1-0.9 microg l(-1) and 0.2-17.8 microg l(-1) at site 1; < 0.1-3.5 microg l(-1), < 0.1-0.2 microg l(-1) and < 0.2-3.2 microg l(-1) at site 2 for simazine, atrazine and diuron, respectively.  相似文献   

5.
Chaves A  Shea D  Danehower D 《Chemosphere》2008,71(4):629-638
We present a method using gas chromatography (GC) and liquid chromatography (LC) coupled to a mass selective detector to measure concentrations of the fungicide chlorothalonil and several of its metabolites in soil and water. The methods employed solid-phase extraction using a hydrophobic polymeric phase for the isolation of analytes. In lake water, average analyte recoveries ranged from 70% to 110%, with exception of pentachloronitrobenzene that gave low recoveries (23%). The method detection limits were determined to be in the range of 1 and 0.1microg l(-1) for the LC and GC methods, respectively. In soil samples, recoveries ranged from 80% to 95% for 4-hydroxy-2,5,6-trichloroisophthalonitrile (metabolite II) and 1,3-dicarbamoyl-2,4,5,6-tetrachlorobenzene (metabolite III). Limits of detection (LOD) were 0.05 and 0.02microg g(-1), respectively. Chlorothalonil and other metabolites were analyzed by GC giving recoveries ranging from 54% to 130% with LOD of 0.001-0.005microg g(-1).  相似文献   

6.
A novel and cost-effective method of sulfosulfuron extraction has been developed using distilled water as an extraction solvent. Using this method, the environmental fate of sulfosulfuron was investigated in soil under wheat crop. Studies were conducted under natural field conditions in randomized block design and herbicide (75% water dispersible granules (WG)) was applied after 24 days of sowing. The rates of applications were 25 and 50 g of active ingredient (a.i.) per hectare. Soil samples were collected at predetermined intervals and analyzed by high performance liquid chromatography (HPLC). The minimum detection limit was found to be 0.001 micro g g(-1). The dissipation of sulfosulfuron followed first-order rate kinetics and dissipated with a half-life of 5.4-6.3 days. After harvest, field soil was used for conducting a pot experiment with bottle gourd (Lagenaria siceraria) as test plants to study the carry over effect of sulfosulfuron. No phytotoxicity was observed to bottle gourd in pot experiment with harvest soil.  相似文献   

7.
A method for trace analysis of two plasticizers, di-2-ethylhexyl phthalate (DEHP) and di-2-ethylhexyl adipate (DEHA), contaminated in packaged curry paste were investigated by gas chromatography with flame ionization detector (GC-FID). Curry paste samples were extracted by ultrasonic and solid phase extraction using Florisil(R) cartridge. Analysis by the GC-FID system provided limits of detection for DEHA and DEHP at 12 and 25 microg L(- 1) and a linear dynamic range between 25 microg L(- 1) to 60 mg L(- 1) with a coefficient of determination (R(2)) greater than 0.99. High recoveries were obtained, ranged from 91 to 99% and 88 to 98% for DEHP and DEHA with RSD lower than 7 and 10% respectively. The method detection limit and limits of quantitation were ranged from 27 to 30 and 90 to 100 microg L(- 1). The analysis of curry paste samples showed concentrations of DEHP and DEHA in the range of 4.0 ng g(- 1) to 0.61 microg g(- 1).  相似文献   

8.
In this work the development, validation and application of method using Solid Phase Microexctration (SPME) for the analyses of five pollutants (phenol, 2-nitrophenol, 2,4-dimethylphenol, 2,4-dichlorophenol and 4-chloro, 3-methyl phenol) in supplying water, using gas chromatography (GC) with flame ionization detector (FID) is described. The optimal conditions obtained for SPME were: fiber type: Poliacrylate (PA); extraction time: 40 minutes; extraction temperature: 70 degrees C; amount of salt added to sample (NaCl): 15%; desorption temperature: 8 minutes. The parameters studied in the method validation were: limit of detection (0.3 and 3.5 microg.L(- 1)); precision, measured by the variation coefficient (between 2.1 and 8.8%); calibration curve and linearity, by using the external standardization method (between 1 and 50 50 microg.L(- 1)). After the methodology development, samples of water collected in Atibaia River (S?o Paulo - Brazil) were analyzed, using the optimized methodology. Three water samples collected in the rain season showed a peak with retention time close to 4-chloro, 3 methyl phenol further analyzed by Gas Chromatography-Mass Spectrometry for the identity confirmation. In spite of the fact that none target compounds were found in the river water samples analyzed, the presence of two phenols different from those investigated (p-terc butyl phenol; butylated hydroxytoluene) were detected. These results together with the results of the limit of detection (that showed to be lower than the maximum concentration of phenols demanded by different environment control agencies), and the results of the validation, indicate the applicability of this method for the analysis of selected phenols in river water samples.  相似文献   

9.
This paper presented a modified method for the analysis of volatile organic sulfides (VOS) simultaneously with volatile organic compounds (VOC) in wastewater using purge-and-trap with gas chromatography/ mass spectrometry. Calibration standards were prepared using filtered and nitrogen-purged VOS-free wastewater, acidified to pH 1.4. Samples were also acidified to pH 1.4. This approach minimized the oxidation of methanethiol to dimethyl disulfide (DMDS), which hampered the liquid-phase analysis of VOS. Compounds were concentrated from the liquid phase, and automated analyses were performed without additional equipment, other than that required for routine wastewater VOC analysis. The linear range was 5 to 500 microg/L, with r2 > or = 0.99. The average recovery from replicate analyses of spiked samples was 81 +/- 0.5% for methanethiol, 100 +/- 1.5% fordimethyl sulfide (DMS), and 92 +/- 1.5% for DMDS. Method detection limits were 4.8, 2.8, and 1.2 microg/L for methanethiol, DMS, and DMDS, respectively. The relative percent differences were between 0 and 8%.  相似文献   

10.
A novel and cost-effective method of sulfosulfuron extraction has been developed using distilled water as an extraction solvent. Using this method, the environmental fate of sulfosulfuron was investigated in soil under wheat crop. Studies were conducted under natural field conditions in randomized block design and herbicide (75% water dispersible granules (WG)) was applied after 24 days of sowing. The rates of applications were 25 and 50 g of active ingredient (a.i.) per hectare. Soil samples were collected at predetermined intervals and analyzed by high performance liquid chromatography (HPLC). The minimum detection limit was found to be 0.001 μ g g? 1. The dissipation of sulfosulfuron followed first-order rate kinetics and dissipated with a half-life of 5.4–6.3 days. After harvest, field soil was used for conducting a pot experiment with bottle gourd (Lagenaria siceraria) as test plants to study the carry over effect of sulfosulfuron. No phytotoxicity was observed to bottle gourd in pot experiment with harvest soil.  相似文献   

11.
Microcystins, toxic cyclic heptapeptides and nodularin-R, a toxic cyclic pentapeptide, were determined using liquid chromatography (LC) with detection using photo-diode array ultra-violet (PDA-UV) and protein phosphatase (PP) assay. Positive fractions were analysed for toxins using collision-induced dissociation (CID) and tandem MS/MS experiments which were carried out simultaneously using electrospray ion-trap instrumentation. Reversed-phase liquid chromatography (LC) using an acetonitrile/water gradient was used for the LC-MS(2) determination of six microcystins standards and nodularin. The molecular related ion species, [M+H](+)([M+2H](2+) in the case of MC-RR), were used as the precursor ions for MS(2) experiments. Optimum calibration and reproducibility data were obtained for MC-LR using LC-MS(2); 0.1-5.0 microg/ml, r2 = 0.992 (n = 3); % RSD < or =7.3 at 0.25 microg MC-LR/ml (n = 3). The detection limit (S/N = 3) was better than 0.1 ng. Water samples for microcystin analysis were first screened using protein phosphatase (PP) assays and positives were concentrated using C-18 solid-phase extraction. The developed method was applied to examine a lake in Ireland contaminated by Microcystis sp. and MC-LR and MC-LA were identified.  相似文献   

12.
In the present work, a sample pre-treatment technique for the determination of trace concentrations of benzene, toluene, ethyl benzene and xylene (BTEX) in aqueous samples has been developed and applied to analysis of the selected analytes in environmental water samples. The extraction procedure is based on coupling polypropylene hollow-fiber liquid phase microextraction (HF-LPME) with gas chromatography by flame ionization detection (GC-FID). The effective parameters such as organic solvent, extraction time, agitation speed and salting effect were investigated. Good reproducibilities of the extraction performance were obtained, with the RSD values ranging from 2.02 to 4.61% (n=5). The method provided 41.47-128.01 fold preconcentration of the target analytes. The limits of detections for the BTEX were in the range of 0.005-03microg ml(-1). In addition, sample clean-up was achieved during LPME due to the selectivity of the hollow fiber, which prevented undesirable large molecules from being extracted. Real samples (River and waste waters) containing BTEX were examined using this method with good linearity and precision (RSDs most lower than 6.00%, n=5). All experiments were carried out at room temperature, 22+/-0.5 degrees C.  相似文献   

13.
Abstract

Four methods were developed for the analysis of fluroxypyr in soil samples from oil palm plantations. The first method involved the extraction of the herbicide with 0.05 M NaOH in methanol followed by purification using acid base partition. The concentrated material was subjected to derivatization and then cleaning process using a florisil column and finally analyzed by gas chromatography (GC) equipped with electron capture detector (ECD). By this method, the recovery of fluroxypyr from the spiked soil ranged from 70 to 104% with the minimum detection limit at 5 µg/kg. The second method involved solid liquid extraction of fluroxypyr using a horizontal shaker followed by quantification using high performance liquid chromatography (HPLC) equipped with UV detector. The recovery of fluroxypyr using this method, ranged from 80 to 120% when the soil was spiked with fluroxypyr at 0.1–0.2 µg/g soil. In the third method, the recovery of fluroxypyr was determined by solid liquid extraction using an ultrasonic bath. The recovery of fluroxypyr at spiking levels of 4–50 µg/L ranged from 88 to 98% with relative standard deviations of 3.0–5.8% with a minimum detection limit of 4 µg/kg. In the fourth method, fluroxypyr was extracted using the solid liquid extraction method followed by the cleaning up step with OASIS® HLB (polyvinyl dibenzene). The recovery of fluroxypyr was between 91 and 95% with relative standard deviations of 4.2–6.2%, respectively. The limit of detection in method 4 was further improved to 1 µg/kg. When the weight of soil used was increased 4 fold, the recovery of fluroxypyr at spiking level of 1–50 µg/kg ranged from 82–107% with relative standard deviations of 0.5–4.7%.  相似文献   

14.
A microanalytical method suitable for the quantitative determination of the sugar anhydride levoglucosan in low-volume samples of atmospheric fine particulate matter (PM) has been developed and validated. The method incorporates two sugar anhydrides as quality control standards. The recovery standard sedoheptulosan (2,7-anhydro-beta-D-altro-heptulopyranose) in 20 microL solvent is added onto samples of the atmospheric fine PM and aged for 1 hr before ultrasonic extraction with ethylacetate/ triethylamine. The extract is reduced in volume, an internal standard is added (1,5-anhydro-D-mannitol), and a portion of the extract is derivatized with 10% by volume N-trimethylsilylimidazole. The derivatized extract is analyzed by gas chromatography/mass spectrometry (GC/MS). The recovery of levoglucosan using this procedure was 69 +/- 6% from five filters amended with 2 microg levoglucosan, and the reproducibility of the assay is 9%. The limit of detection is approximately 0.1 microg/mL, which is equivalent to approximately 3.5 ng/m3 for a 10 L/min sampler or approximately 8.7 ng/m3 for a 4 L/min personal sampler (assuming 24-hr integrated samples). We demonstrated that levoglucosan concentrations in collocated samples (expressed as ng/m3) were identical irrespective of whether samples were collected by PM with aerodynamic diameter < or = 2.5 microm or PM with aerodynamic diameter < or = 10 microm impactors. It was also demonstrated that X-ray fluorescence analysis of samples of atmospheric PM, before levoglucosan determinations, did not alter the levels of levoglucosan.  相似文献   

15.
Movement of bromacil and hexazinone in soils of Hawaiian pineapple fields   总被引:1,自引:0,他引:1  
Zhu Y  Li QX 《Chemosphere》2002,49(6):669-674
Bromacil and hexazinone have been heavily used to control weeds in the pineapple fields in central Oahu, Hawaii, USA, since 1970s and 1980s, respectively. The last application prior to this study was at a rate of 0.6 kg active ingredient (a.i.) ha(-1) for hexazinone and 1.8 or 3.4 kg (a.i.) ha(-1) for bromacil in the six study fields during June-October 1998. Soils were collected from 0 to 1860 cm below the surface in January-May 1999 to survey the residue profiles of the two herbicides. Stratoprobe sampling showed to be an efficient and convenient method for deep soil cores. Bromacil was detected in all the soil samples above 60 cm (105-1338 ng g(-1) dry weight) and in 74% of the samples above 400 cm (26-473 ng g(-1)). Trace amounts of bromacil (90-113 ng g(-1)) were detected in some of the samples collected from as deep as 1540 cm. Hexazinone was detected in three of the six fields at 0-60 cm only (86-107 ng g(-1) dry weight). The more frequent detection of bromacil at higher concentrations than hexazinone is related to the prolonged higher application rates of bromacil in the fields and its higher persistence and mobility in soil.  相似文献   

16.
A high-performance liquid chromatography method with diode-array detection (HPLC-DAD) is described for the determination of three neonicotinoid insecticides imidacloprid, thiacloprid, and thiamethoxam in soil and water. The soil samples were extracted with acetonitrile, while the water samples were extracted using C18 cartridges. The mean recoveries plus standard deviations for spiked soil samples were 82 +/- 4.2% for thiamethoxam, 99 +/- 4.2% for imidacloprid and 94 +/- 1.4% for thiacloprid. The recoveries for water samples ranged from 87 +/- 3.4% for thiamethoxam to 97 +/- 3.9% for imidacloprid and 97 +/- 2.6% for thiacloprid. The limits of quantitation (LOQ) were 0.1, 0.1, 0.01 mg/kg in soil (5g), and 2, 2, 0.5, micro/L in water (50 mL) for thiamethoxam, imidacloprid, and thiacloprid, respectively.  相似文献   

17.
Alavi G  Sanda M  Loo B  Green RE  Ray C 《Chemosphere》2008,72(1):45-52
Recent discovery of low concentrations of bromacil in drinking water prompted the State of Hawaii to examine the leaching behavior of bromacil in pineapple fields. This study is a follow up to earlier work on bromacil concentrations in soil profiles in a pineapple field in central Oahu, Hawaii. Soil samples were collected for bromacil analysis at different times prior to and after application from a pineapple field that was previously surveyed by other research workers. The leaching pattern of bromacil was further investigated at two different application rates (2.25 and 1.8 kg ha(-1)). The concentration of bromacil in the topsoil about 100 days after bromacil application (1.8 kg ha(-1)) was substantially higher in 2002 compared to 1999. The distribution profiles were generally consistent with the one presented in the previous study. Residual bromacil was present in the entire sampled zone (3m deep) about 18 months after the previous bromacil application. Over a period of 9 months, there was substantial dissipation of bromacil residue present in the topsoil. The residual concentration of bromacil in the area that received the reduced application rate (1.8 kg ha(-1)) were lower than those receiving the current application rate (2.25 kg ha(-1)) and the depth of penetration of the bromacil front was shallower at the reduced application rate. Because of the common practice of placing plastic mulch around the base of the pineapple plants to retain volatile nematicides, the applied bromacil was found to be concentrated in the areas between the plastic mulch, transported by runoff from the plastic. The study results encourage the use of less than the label led rate of application of bromacil for pineapple fields.  相似文献   

18.
This paper describes a new analytical method for determination of organophosphorus pesticides (OPs) along with their degradation products involving liquid chromatography (LC) positive ion electrospray (ESI+) tandem mass spectrometry (MS-MS) with selective reaction monitoring (SRM). Chromatography was performed on a Gemini C6-Phenyl (150 mmx2.0 mm, 3 microm) with a gradient elution using water-methanol with 0.1% formic acid, 2 mM ammonium acetate mobile phase at a flow rate of 0.2 mL min(-1). The LC separation and MS/MS operating conditions were optimized with a total analysis time less than 40 minutes. Method detection limits of 0.1-5 microg L(-1) for selected organophosphorus pesticides (OP), OP oxon degradation products, and other degradation products: 3,5,6-trichloro-2-pyridinol (TCP); 2-isopropyl-6-methyl-4-pyrimidol (IMP); and diethyl phosphate (DEP). Some OPs such as fenchlorphos are less sensitive (MDL 30 microg L(-1)). Calibration curves were linear with coefficients of correlation better than 0.995. A three-point identification approach was adopted with area from first selective reaction monitoring (SRM) transition used for quantitative analysis, while a second SRM transition along with the ratio of areas obtained from the first to second transition are used for confirmation with sample tolerance established by the relative standard deviation of the ratio obtained from standards. This new method permitted the first known detection of OP oxon degradation products including chlorpyrifos oxon at Bratt's Lake, SK and diazinon oxon and malathion oxon at Abbotsford, BC in atmospheric samples. Atmospheric detection limits typically ranged from 0.2-10 pg m(-3).  相似文献   

19.
Ferrari S  Mandel F  Berset JD 《Chemosphere》2002,47(2):173-182
An analytical method was developed to determine quantitatively 1-hydroxypyrene (OHP) in bovine urine samples. The procedure includes an enzymatic hydrolysis to cleave the conjugated metabolite, an enrichment step using solid phase extraction with a non-polar rinse step and elution with dichloromethane. A final clean-up on silicagel was performed before high-performance liquid chromatography (HPLC) analysis and fluorescence detection. Alternatively, HPLC and electrospray ionization in the negative ion mode applying selective ion monitoring acquisition revealed to be a highly sensitive detection method allowing the quantitation of low pg of OHP in the urine samples. The method was successfully applied to the determination of OHP in bovine urine samples from animals living in urban and rural areas. Urine concentrations of OHP were significantly higher (median 8.6 microg l(-1)) of bovines living close to a highway.  相似文献   

20.
A new approach to surface water analysis has been investigated in order to enhance the detection of different organic contaminants in Nathan Creek, British Columbia. Water samples from Nathan Creek were prepared by liquid/liquid extraction using dichloromethane (DCM) as an extraction solvent and analyzed by gas chromatography mass spectrometry method in scan mode (GC-MS scan). To increase sensitivity for pesticides detection, acquired scan data were further analyzed by Automated Mass Spectrometry Deconvolution and Identification Software (AMDIS) incorporated into the Agilent Deconvolution Reporting Software (DRS), which also includes mass spectral libraries for 567 pesticides. Extracts were reanalyzed by gas chromatography mass spectrometry single ion monitoring (GC-MS-SIM) to confirm and quantitate detected pesticides. Pesticides: atrazine, dimethoate, diazinone, metalaxyl, myclobutanil, napropamide, oxadiazon, propazine and simazine were detected at three sampling sites on the mainstream of the Nathan Creek. Results of the study are further discussed in terms of detectivity and identification level for each pesticide found. The proposed approach of monitoring pesticides in surface waters enables their detection and identification at trace levels.  相似文献   