首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 265 毫秒
1.
Anderson DR  Fisher R 《Chemosphere》2002,46(3):371-381
Several countries have compiled national inventories of dioxin (polychlorinated dibenzo-p-dioxin [PCDD] and polychlorinated dibenzofuran [PCDF]) releases that detail annual mass emission estimates for regulated sources. High temperature processes, such as commercial waste incineration and iron ore sintering used in the production of iron and steel, have been identified as point sources of dioxins. Other important releases of dioxins are from various diffuse sources such as bonfire burning and domestic heating. The PCDD/F inventory for emissions to air in the UK has decreased significantly from 1995 to 1998 because of reduced emissions from waste incinerators which now generally operate at waste gas stack emissions of 1 ng I-TEQ/Nm3 or below. The iron ore sintering process is the only noteworthy source of PCDD/Fs at integrated iron and steelworks operated by Corus (formerly British Steel plc) in the UK. The mean waste gas stack PCDD/F concentration for this process is 1,2 ng I-TEQ/Nm3 based on 94 measurements and it has been estimated that this results in an annual mass release of approximately 38 g I-TEQ per annum. Diffuse sources now form a major contribution to the UK inventory as PCDD/Fs from regulated sources have decreased, for example, the annual celebration of Bonfire Night on 5th November in the UK causes an estimated release of 30 g I-TEQ, similar to that emitted by five sinter plants in the UK.  相似文献   

2.
Ok G  Ji SH  Kim SJ  Kim YK  Park JH  Kim YS  Han YH 《Chemosphere》2002,46(9-10):1351-1357
The atmospheric contamination levels of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) were evaluated from the analysis of pine needles in South Korea. Pine needles were collected from 30 sampling points at five main cities in South Korea (Busan, Daegu, Gwangju, Changwon and Jeju island). The highest concentrations of PCDDs/DFs (2.19–26.88 pg I-TEQ/g of dry weight) were measured at Busan, where is the city of the highest population density and traffic volume among five cities. The lowest concentration was detected at Jeju with 0.62 pg I-TEQ/g dry weight, suggesting Jeju could be an environmental background area in Korea. The dominant homologues of PCDDs/DFs in pine needles were the lower chlorine-substituted compounds such as tetra CDDs and CDFs, and the distribution ratios of PCDDs/DFs decreased with increase of the number of chlorine substituents. Homologue profiles of pine needle samples were similar to PCDDs/DFs profiles of the vapor phase in the ambient air, and thus the pine needles absorbed the vapor phase of PCDDs/DFs from air. Results suggested that pine needles could be used as an indicator of the atmospheric contamination for PCDDs/DFs in Korea.  相似文献   

3.
The present study was intended to establish an inventory of PCDD/F emissions in Tarragona Province (Catalonia, NE Spain), as a preliminary phase in the development of a flow analysis of PCDD/Fs in this Province. In 1999, global PCDD/F emissions reached a value of 2.24 g I-TEQ/y, which means a density of 3.8 micrograms I-TEQ/inhabitant/y. The low amount of PCDD/Fs emitted to air by the only municipal solid waste incinerator in the Province (approximately 0.04% of the total) has been one of the most notable results. As a reflection of uncertainties in the estimates for individual sources, the 90th percentiles of PCDD/F releases for 1999 ranged up to 4.1 g I-TEQ/y.  相似文献   

4.
This study investigates the emissions of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) from four electric arc furnaces (EAFs) and eight secondary aluminum smelters (secondary ALSs) in Taiwan. The mean PCDD/F International-Toxicity Equivalents (I-TEQ) concentrations in the stack gases of these EAFs and secondary ALSs are 0.28 ng I-TEQ/Nm3 (relative standard deviation [RSD]= 100%) and 3.3 ng I-TEQ/Nm3 (RSD = 260%), respectively. The high RSDs, especially for those obtained from secondary ALSs, could be caused by the intrinsic differences in their involved feeding materials, furnace operating conditions, and air pollution control devices. The mean I-TEQ emission factor of PCDD/Fs for EAFs (1.8 microg I-TEQ/tonne-feedstock) is lower than that for secondary ALSs (37 microg I-TEQ/tonne-feedstock). This result might be because the involved furnace temperatures for secondary ALSs (650-750 degrees C) are lower than those for EAFs (1600-1700 degrees C), resulting in the deterioration of the combustion condition, leading to the formation of PCDD/Fs during the industrial process. This study found that the total PCDD/F emissions from EAFs (20 g I-TEQ/yr) and secondary ALSs (18 g I-TEQ/yr) are approximately 27, 53, and approximately 24, 49 times higher than those from municipal solid waste incinerators (MSWIs; 0.74 g I-TEQ/yr) and medical waste incinerators (MWIs; 0.37 g I-TEQ/yr), respectively; while those are 44 and 40% of total PCDD/F emission from sinter plants (45 g I-TEQ/ yr), respectively. Considering a more stringent emission limit has been applied to waste incinerators (0.1 ng I-TEQ/Nm3) in Taiwan lately, the results suggest that the control of the emissions from metallurgical processes has become the most important issue for reducing the total PCDD/F emission from industrial sectors to the ambient environment.  相似文献   

5.
Fabrellas B  Sanz P  Abad E  Rivera J 《Chemosphere》2001,43(4-7):683-688
The main objectives of the Spanish dioxin inventory and the incidence of municipal waste incinerators in the PCDD/Fs releases in the period from January 1997-November 1999 are presented. Preliminary data about the stack emission levels, fly ashes and slags as solid residues and the PCDD/Fs input in the USW are also presented to elaborate an initial balance for the incineration sector. A great decrease, from 20 to 1.2 g I-TEQ/y, from incineration gas emissions has been observed since 1996. The preliminary balance in the MWI sector suggests an overall PCDD/Fs destruction. The calculated emission factor, 1.06 microg I-TEQ/Mg, indicates a high quality of the air pollution control systems. The assumption of PCDD/Fs in the USW permits an initial evaluation of other waste management systems.  相似文献   

6.
Control of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) in emissions and thermal residues from incinerators has been a cause of public concern for more than one decade. Recently, several studies showed that other persistent organic pollutants (POPs) such as coplanar polychlorinated biphenyls (co-PCBs) also have dioxin-like activity and are released from incinerators. Therefore, the present study was aimed at making a risk assessment about dioxin-like activity in extracts of thermal waste residues (e.g. combustion gas; fly ash, slag) from incineration and melting processes in Germany and Japan. For this purpose, polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs), coplanar polychlorinated biphenyls (co-PCBs), polychlorinated naphthalenes (PCNs) and polyaromatic hydrocarbons (PAHs) were analyzed by chemical analysis. Additionally, 2, 3, 7, 8-TCDD equivalents (EROD-TEQs) were determined by in vitro Micro-EROD bioassay using rat H4IIE hepatoma cells. EROD-TEQs could be correlated to I-TEQ values (from PCDD/Fs/co-PCBs) analyzed by chemical analysis resulting in a maximal sixfold higher estimate. Our study indicates minor influences of co-PCBs, PAHs and PCNs to the sum of dioxin-like toxicity in the extracts of thermal waste residues as determined here. Furthermore, we showed that the levels of dioxins and co-PCBs contained in slag from melting processes and bottom ashes from incineration processes were lower by 1-2 orders of magnitude than that in fly ash.  相似文献   

7.
Yu BW  Jin GZ  Moon YH  Kim MK  Kyoung JD  Chang YS 《Chemosphere》2006,62(3):494-501
The metallurgy industry and municipal waste incinerators are considered the main sources of polychlorinated dibenzo-p-dioxin and dibenzofurans (PCDD/Fs) in many countries. This study investigated the emission factors and total emissions of PCDD/Fs and dioxin-like polychlorinated biphenyls (PCBs) emitted from metallurgy industries (including ferrous and nonferrous foundries) in Korea. The toxic equivalency (TEQ) emission factor of PCDD/Fs was the highest for secondary copper production, at 24451 ng I-TEQ/ton. The total estimated emissions of PCDD/Fs from these sources were 35.259 g I-TEQ/yr, comprising 0.088 g I-TEQ/yr from ferrous foundries, 31.713 g I-TEQ/yr from copper production, 1.716 g I-TEQ/yr from lead production, 0.111 g I-TEQ/yr from zinc production, and 1.631 g I-TEQ/yr from aluminum production. The total estimated annual amounts of dioxin-like PCBs emitted from these sources were 13.260 g WHO-TEQ/yr, comprising 0.014 g WHO-TEQ/yr from ferrous foundries, 12.675 g WHO-TEQ/yr from copper production, 0.170 g WHO-TEQ/yr from lead production, 0.017 g WHO-TEQ/yr from zinc production, and 0.384 g WHO-TEQ/yr from aluminum production. The highest emission factor was found for secondary copper smelting, at 9770 ng WHO-TEQ/ton.  相似文献   

8.
Alcock RE  Gemmill R  Jones KC 《Chemosphere》1999,38(4):759-770
PCDD/F data are presented from 75 samples of primary emissions sampled between 1995-97 as part of the compliance monitoring survey undertaken by the UK Environment Agency. Municipal solid waste (MSW), chemical waste and clinical waste incinerators, cement kilns, sinter plants and sewage sludge incinerators were the source categories monitored and reported here. Based on this monitoring programme, the previous national UK emission estimates by Eduljee and Dyke (1) of 560-1100 g I-TEQ a(-1) for 1993 have been revised downwards to 220-660 g I-TEQ a(-1). Despite source reduction measures, MSW incinerators remain a significant source of PCDD/Fs to the atmosphere, contributing between 30-50% of the EPCDD/F I-TEQ emission, rather than the approximately 80% they were estimated to contribute in 1993. 2,3,7,8-substituted PCDD/F congener profile data are presented for some of the source categories and generally support the view that differences in the mixtures ('fingerprints') of PCDD/Fs emitted from different sources are observed. New data on the dioxin-like PCB emissions are presented for cement kilns and sinter plants. These show that TEQ-rated PCBs can make an important contribution to the I-TEQ emitted from certain combustion sources. High concentrations of a full range of PCB congeners/homologues have been measured in the atmosphere close to sintering strands, although the precise source of PCBs from this process remains unclear.  相似文献   

9.
Substance Flow Analysis (SFA) is an important instrument that allows for the undertaking of environmental management for a specific contaminant. 'Control Analysis' is a tool that assesses the effect on a target flow of changes in flows forming part of a control basis set. The purpose of the present study was to perform a modeling of the annual PCDD/F flows in Tarragona Province and to apply the model for human health risk assessment. The validation of the model has been evaluated by comparing estimated fluxes with experimental values. Eleven subsystems, as well as a set of 88 flows of the system in Tarragona Province were considered. The total PCDD/F accumulation in Tarragona Province was between 62.6 and 159.5 g I-TEQ/y. Accumulation in sediments (27.9-74.6 g I-TEQ/y) and soils (35.0-80.8 g I-TEQ/y) are the two principal modes of deposition. Estimated flow in human adipose tissue means a mean intake of PCDD/F (via ingestion and inhalation) of 243 pg I-TEQ/person/day. The food chain pathway accounts for 99% of the total daily intake. As a result of the simulation, a 100% decrease in industrial emissions would cause a 1.7% reduction in the PCDD/F accumulation in humans. In turn, a 100% reduction of PCDD/Fs in the industrial waste waters would cause only an insignificant 0.1% decrease in the accumulation of PCDD/Fs in humans.  相似文献   

10.
Oh JE  Choi SD  Lee SJ  Chang YS 《Chemosphere》2006,64(4):579-587
To examine the influence of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) emissions from a municipal solid waste incinerator (MSWI) on the environment, we measured the levels of PCDD/Fs in ambient air and soil samples collected near a MSWI in Bucheon, Korea. The PCDD/Fs concentrations in the ambient air samples ranged from 0.22 to 1.16 pg I-TEQm(-3) (13.39-75.16 pg m(-3)), with an average of 0.66 pg I-TEQ m(-3) (35.62 pg m(-3)). The soil samples contained between 1.25 and 74.98 pg I-TEQ g(-1) (38.15-3,303.33 pg g(-1)), with an average of 19.06 pg I-TEQ g(-1) (1,077.11 pg g(-1)). These levels were higher than those previously reported by other investigators in a number of surveys. The furan homologues predominated in the air samples and some soil samples, and the soil PCDD/Fs levels decreased with increasing distance from the MSWI. Comparison of the homologue patterns and a multivariate statistical analysis showed that PCDD/Fs emission from the MSWI directly affected the pattern of PCDD/Fs in air, while the PCDD/Fs patterns in soil differed according to the location relative to the MSWI, roads, and construction sites. These results collectively indicate that the MSWI was the major PCDD/Fs emission source in this area, but that unidentified combustion sources and vehicles might influence the environment to some extent.  相似文献   

11.
The aim of this study is improving currently applied methodology for spatial disaggregation, as well as mapping air emission inventories by taking into account the auxiliary spatial data on population density. District heating infrastructure occurring in more populated areas changes distinctly the spatial distribution of estimated air emission; however, it does not change the initial estimate. That means the total, disaggregated value is constant. Considered sources of domestic combustion are located in the central part of the Silesian Metropolis, in the southern part of Poland. A large part of this area is strongly urbanized and supplied with heat (hot water) from the district heating system. Data on population density help to determine the area within which the dwellers use heat energy and hot water supplied by the heating infrastructure, apart from heating with small domestic boilers and stoves. This causes the domestic combustion’s emission impact within the distinguished area to be significantly lower in comparison to the official guidelines on air emission inventories. The important differences in spatial air emissions distributions calculated using a top-down approach are found for strongly urbanized areas supplied partly with heat and hot water from the district heating network. This fact should be taken into account when preparing detailed, high-resolution emission inventories for air regional and local quality modeling.

Implications: The spatial issues connected with elaboration of the high-resolution emission inventories are presented for the example of the populated area of the Silesian Metropolis (Poland). Spatial distribution of the population density is used to determine the area supplied with heat and hot water from the district heating system. It changes distinctly the spatial distribution of the air emission from small residential combustion sources.  相似文献   


12.
Lee SJ  Choi SD  Jin GZ  Oh JE  Chang YS  Shin SK 《Chemosphere》2007,68(5):856-863
Municipal solid waste incinerators (MSWIs) have been shown to be important sources of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). The emission of PCDD/Fs by MSWIs is a controversial subject in human health risk assessment. In this study the effect of a MSWI on a residential area was assessed before and after the installation of an additional treatment system for flue gas. This additional treatment system resulted in a dramatic decrease in PCDD/F concentrations in stack flue gas samples by 99.98%, while the concentrations in air decreased by approximately 50% (36,500 and 0.75 pg I-TEQ m(-3) for air in 1999; 3.5 and 0.38 pg I-TEQ m(-3) in 2002; 1.6 and 0.076 pg I-TEQ m(-3) in 2005 for stack gas and air, respectively). Considering the congener distributions of PCDD/Fs between stack flue gas and air samples, the study area seemed to have been contaminated by other urban sources as well as the MSWI. ISC3 model results support the conclusion that this incinerator became only a minor contributor to the study area after installation of the supplementary systems. This resulted from both proper MSWI operation using modern technology and additional sources of contaminants in this region. Finally, PCDD/F uptake by humans through inhalation of contaminated air was estimated. Assuming that inhalation exposure contributes 10% of total exposure, total exposure was lower than WHO guidelines. These results confirm that proper operation and maintenance of the incinerator led to a reduction in emissions and potential health impacts of PCDD/Fs.  相似文献   

13.
PCDD/F emissions from heavy duty vehicle diesel engines   总被引:1,自引:0,他引:1  
Geueke KJ  Gessner A  Quass U  Bröker G  Hiester E 《Chemosphere》1999,38(12):2791-2806
The currently available information on PCDD/F emissions from diesel vehicles is briefly surveyed. Considerable uncertainty is identified concerning the emissions from heavy duty diesel trucks which have been measured only twice so far. These measurements led to emission factors differing by a factor of 200; similar discrepancy was also revealed by measurements of ambient air in traffic tunnels. New PCDD/F emission measurement results are presented which have been carried out at the exhaust systems of a stationary engine and of a modern heavy duty vehicle engine at transient operation conditions simulated on a test bench. PCDD/F concentrations in the exhaust gases were found to be in the range of control blank samples. Based on the highest concentration observed in the truck engine exhaust (9.7 pg I-TEQ/dry standard m3) a worst case estimate of the annual PCDD/F emission freight from diesel fuel combustion in the European countries of about 30 g I-TEQ/year is calculated. This emission appears to be irrelevant compared to the overall emission rate of more than 6,000 g I-TEQ/year being inventoried recently. Finally the possibilities to link congener/homologue profiles of diesel emission to profiles found in food or human samples are discussed.  相似文献   

14.
In this work, the findings of the first assessment of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in emissions releases to the atmosphere from coal-fired power plants are given. A total of five plants were selected for the study located at different provinces in Spain. In all the cases, the results revealed very low levels, in the range of 0.41 pg I-TEQ/Nm(3). The profile indicated in the majority of the cases predominance of highly chlorinated congeners being OCDD the most important contributor. The findings were also used to estimate contribution of PCDDs/PCDFs emitted from coal-fired power plants in Spain. Individual plant results revealed values below 0.02 g I-TEQ per year and plant. Nevertheless, considering the total coal consumption in Spain in 1997, the values are comparable to those reported in other countries in the range of 0.6-0.7 g I-TEQ per year. Moreover, emission factors were determined considering operating conditions of evaluated plants. In general, large variability was observed and values below 1-5 pg I-TEQ/kg coal were early reached.  相似文献   

15.
Malisch R  Dilara P 《Chemosphere》2007,67(9):S79-S89
Milk and milk products have shown to be good indicator samples for the contamination of persistent organic pollutants (POPs) along the food chain. To gather information on whether exposure to dioxins and PCBs might cause a problem in countries about to join the European Union in 2004 or later, a study for evaluation of dioxin and levels of PCBs in 16 butter samples from eight countries (Cyprus, Czech Republic, Estonia, Lithuania, Poland, Romania, Slovenia and Slovakia) was performed. Comprehensive quality assurance/quality control (QA/QC) was requested. For this, eight quality control samples were included (in comparison to long-term mean, mean recovery for WHO-PCDD/F-TEQ of 97.9% with a CV of 3.0%, mean recovery for WHO-PCB-TEQ of 100.4% with a CV of 3.3%). Additionally, all butter samples were run as duplicates resulting in a confidence region of 95% statistical certainty of 4.6% for WHO-PCDD/F-TEQ and of 3.5% for WHO-PCB-TEQ. All samples except one from Romania were in the range of 0.21-0.59 pg WHO-PCDD/F-TEQ/g fat (upper bound), all samples except one from Romania and one from Estonia in the range of 0.32-0.82 pg WHO-PCB-TEQ/g fat (upper bound) and all samples except one from Romania and one from Estonia in the range of 0.57-1.23 pg sum WHO-TEQ/g fat (upper bound). The maximum values were found in samples from Romania (0.98 pg WHO-PCDD/F-TEQ/g fat; 1.75 pg WHO-PCB-TEQ/g fat) and Estonia (0.26 pg WHO-PCDD/F-TEQ/g fat; 1.62 pg WHO-PCB-TEQ/g fat). As a conclusion, all samples except one from Romania and one from Estonia were in the range of the actual low background contamination for PCDD/F and dioxin-like PCBs. The samples with elevated concentrations were below the EU action and maximum levels which have been valid since 2002, or will be applied from November 2006. In all samples except in one from Estonia, the contribution of dioxin-like PCBs to sum WHO-TEQ was 47-68% which reflects the usual range in Europe. In one sample from Estonia this contribution was 86% which points to a particular yet unknown PCB source. Thirty eight PCB congeners were determined allowing a detailed discussion of the relative contribution of individual congeners to the total PCB concentration. Correlation between PCB 153 and WHO-PCB-TEQ varied considerably between samples from different countries. Major tetra- or pentachlorinated mono-ortho PCBs without assigned TEFs were PCBs 60, 66, 74, and 110.  相似文献   

16.
A survey to estimate the polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) emissions of Spanish hot dip galvanising sector was carried out during 2002. This investigation is the first presenting Spanish experimental data related to this industrial sector. Three different matrices: flue gas, ash and filter dust were tested to quantify the PCDD/Fs generated during the galvanising process. The organic source of PCDD/F formation could be from the insufficient degreasing o from inhibitors or additives used in the pickling steps such as quinoline, isoquinoline, 8-methylquinoline or polyether phosphoric acid. Low levels PCDD/Fs were achieved in air emissions when air control devices are used. On the contrary, filter dusts are highly contaminated; indicating that the absence of air control devices would increase the risk of fugitive emissions. Homologue profiles and Principal Component Analysis demonstrate there are differences in the formation mechanisms in the bath zone (ashes) compared to the stack location (filter dusts and air emissions), related to the de novo synthesis and reaction time. The annual PCDD/F emission to the atmosphere for this sector during 2002 has been estimated in 0.023g I-TEQ. The emission factor of plants with air control devices has been calculated at 0.030microg I-TEQ/ton of galvanised steel.  相似文献   

17.
Levels of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) in both air and soil samples were measured at three different sites in Italy, in proximity to three municipal solid waste incinerators (MSWIs) to determine baseline contamination and the contributory role of incinerator emissions. At the first site, located in an agricultural, cattle-breeding, typically flattish area of the Po Valley, the dioxin concentrations had already been measured before the start-up of the new MSWI. These dioxin concentrations were then again measured after two years of continual operation of the incinerator. Despite the presence of the plant, the PCDD/Fs concentrations appear not to have been affected and were found to be in a range of 22-125 fg I-TEQ m(-3) in the air samples and 0.7-1.5 pg I-TEQ g(-1) in the soil samples. The second site is located in an industrial district of the Veneto Region, in the surroundings of an old MSWI that is not equipped with Best Available Technology (BAT) dioxin removal system. The PCDD/Fs concentrations in the air samples were between 144 and 337 fg I-TEQ m(-3). This is a typical range of values for industrial areas, while the soil samples showed contamination levels between 1.1 and 1.4 pg I-TEQ g(-1). The third site lies in the Adige Valley, near a MSWI that has been equipped with BAT for flue gas cleaning. The observed values ranged from 10 to 67 fg I-TEQ m(-3) for the air samples and 0.08-1.2 pg I-TEQ g(-1) for the soil samples. The contributory factors of the varying characteristics of the different areas together with the types of technology adopted at each MSWI plant are discussed. The PCDD/Fs levels are subsequently compared with established values from previous studies.  相似文献   

18.
Endosulfan in China 2—emissions and residues   总被引:4,自引:0,他引:4  
Background, aim, and scope  Endosulfan is one of the organochlorine pesticides (OCPs) and also a candidate to be included in a group of new persistent organic pollutants (UNEP 2007). The first national endosulfan usage inventories in China with 1/4° longitude by 1/6° latitude resolution has been reported in an accompanying paper. In the second part of the paper, we compiled the gridded historical emissions and soil residues of endosulfan in China from the usage inventories. Based on the residue/emission data, gridded concentrations of endosulfan in Chinese soil and air have been calculated. These inventories will provide valuable data for the further study of endosulfan. Methods  Emission and residue of endosulfan were calculated from endosulfan usage by using a simplified gridded pesticide emission and residue model—SGPERM, which is an integrated modeling system combining mathematical model, database management system, and geographic information system. By using the emission and residue inventories, annual air and soil concentrations of endosulfan in each cell were determined. Results and discussion  Historical gridded emission and residue inventories of α- and β-endosulfan in agricultural soil in China with 1/4° longitude by 1/6° latitude resolution have been created. Total emissions were around 10,800 t, with α-endosulfan at 7,400 t and β-endosulfan at 3,400 t from 1994 to 2004. The highest residues were 140 t for α-endosulfan and 390 t for β-endosulfan, and the lowest residues were 0.7 t for α-endosulfan and 170 t for β-endosulfan in 2004 in Chinese agricultural soil where endosulfan was applied. Based on the emission and residue inventories, concentrations of α- and β-endosulfan in Chinese air and agricultural surface soil were also calculated for each grid cell. We have estimated annual averaged air concentrations and the annual minimum and maximum soil concentrations across China. The real concentrations will be different from season to season. Although our model does not consider the transport of the insecticide in the atmosphere, which could be very important in some areas during some special time, the estimated concentrations of endosulfan in Chinese air and soil derived from the endosulfan emission and residue inventories are in general consistent with the published monitoring data. Conclusions  To our knowledge, this work is the first inventory of this kind for endosulfan published on a national scale. Concentrations of the chemical in Chinese air and agricultural surface soil were calculated for each grid cell. Results show that the estimated concentrations of endosulfan in Chinese air and soil agree reasonably well with the monitoring data in general. Recommendations and perspectives  The gridded endosulfan emission/residue inventories and also the air and soil concentration inventories created in this study will be updated upon availability of new information, including usage and monitoring data. The establishment of these inventories for the OCP is important for both scientific communities and policy makers.  相似文献   

19.
Only a few data are reported about the formation of polychlorinated dibenzo-p-dioxins (PCDD) and dibenzofurans (PCDF) in forest fires. However, the inventories of sources undertaken by several European and American countries consider natural fires as a possible source of PCDD/F and, in some cases, as one of the most important. In our work we have analysed vegetation and soil samples burned in four forest fires which happened in Catalonia in the summer of 1998. The concentration of dioxin-like compounds (PCDD/F, non-ortho polychlorinated bi-phenyls (PCB) and mono-ortho PCB) has been compared to the concentration present in the corresponding unburned material collected in places near the fires but not affected. The results of this preliminary study show very low concentrations in all the samples, both burned and unburned. Although a change in the profile (proportional increase of tetrachlorinated congeners in PCDD/F) is observed in burned samples compared to unburned ones, the absolute values of concentration decrease in most samples. Therefore, natural fires seem not to be an important source of dioxin-like compounds. These results will be confirmed with air emissions measurements in future studies.  相似文献   

20.
Municipal solid waste incinerators (MSWIs) have long been the major contributors of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) to ambient air in Taiwan. After stringent MSWI emission standards were introduced in 2001, the long-term continuous monitoring of flue gas and ambient air quality became necessary to ensure the effectiveness of the related control strategies. Three MSWIs and the surrounding ambient air were investigated in the current study for PCDD/F characteristics during 2006 to 2011. The average concentrations in the flue gas ranged from 0.008?~?0.0488 ng I-TEQ/Nm3, which is much less than the emission standard in Taiwan (0.1 ng I-TEQ/Nm3) (I-TEQ is the abbreviation of International Toxic Equivalent). This led to extremely low levels in the ambient air, 0.0255 pg I-TEQ/Nm3, much less than the levels seen in most urban areas around the world. Additionally, the results obtained using the Industrial Source Complex Short-Term Dispersion Model (ISCST3) indicate that the PCDD/F contributions from the three MSWIs to the ambient air were only in the range from 0.164?~?0.723 %. Principal component analysis (PCA) showed that the PCDD/Fs in the air samples had very similar characteristics to those from mobile sources. The results thus show that stringent regulations have been an effective control strategy, especially for urban areas, such as Taipei City.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号