首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
Boiler briquette coal versus raw coal: Part I--Stack gas emissions   总被引:1,自引:0,他引:1  
Stack gas emissions were characterized for a steam-generating boiler commonly used in China. The boiler was tested when fired with a newly formulated boiler briquette coal (BB-coal) and when fired with conventional raw coal (R-coal). The stack gas emissions were analyzed to determine emission rates and emission factors and to develop chemical source profiles. A dilution source sampling system was used to collect PM on both Teflon membrane filters and quartz fiber filters. The Teflon filters were analyzed gravimetrically for PM10 and PM2.5 mass concentrations and by X-ray fluorescence (XRF) for trace elements. The quartz fiber filters were analyzed for organic carbon (OC) and elemental carbon (EC) using a thermal/optical reflectance technique. Sulfur dioxide was measured using the standard wet chemistry method. Carbon monoxide was measured using an Orsat combustion analyzer. The emission rates of the R-coal combustion (in kg/hr), determined using the measured stack gas concentrations and the stack gas emission rates, were 0.74 for PM10, 0.38 for PM2.5, 20.7 for SO2, and 6.8 for CO, while those of the BB-coal combustion were 0.95 for PM10, 0.30 for PM2.5, 7.5 for SO2, and 5.3 for CO. The fuel-mass-based emission factors (in g/kg) of the R-coal, determined using the emission rates and the fuel burn rates, were 1.68 for PM10, 0.87 for PM2.5, 46.7 for SO2, and 15 for CO, while those of the BB-coal were 2.51 for PM10, 0.79 for PM2.5, 19.9 for SO2, and 14 for CO. The task-based emission factors (in g/ton steam generated) of the R-coal, determined using the fuel-mass-based emission factors and the coal/steam conversion factors, were 0.23 for PM10, 0.12 for PM2.5, 6.4 for SO2, and 2.0 for CO, while those of the BB-coal were 0.30 for PM10, 0.094 for PM2.5, 2.4 for SO2, and 1.7 for CO. PM10 and PM2.5 elemental compositions are also presented for both types of coal tested in the study.  相似文献   

2.
As part of an international research project, aerosol samples were collected by several filter-based devices on Nuclepore polycarbonate membrane, Teflon membrane and quartz fibre filters over separate daylight periods and nights, and on-line aerosol measurements were performed by TEOM and aethalometer within an urban canyon (kerbside) and at a near-city background site in Budapest, Hungary from 23 April–5 May 2002. Aerosol masses in PM2.0, PM10–2.0, PM2.5, PM10 size fractions and of TSP were determined gravimetrically; atmospheric concentrations of organic (OC) and elemental carbon (EC) for PM2.5 (or PM2.0), PM10 fractions and for TSP were measured by thermal–optical transmission method. Repeatability of the mass determination by Nuclepore filters seems to be 5–6%. Collections on Teflon filters yielded smaller mass on average by 8(±12)% than that for the Nuclepore filters. Quartz filters overestimated the PM10 mass in comparison with the Nuclepore filters due primarily to sampling artefacts on average by 10(±16)% at the kerbside. Tandem filter set-ups were utilised for correcting the sampling artefacts for OC by subtraction method. At the kerbside, the aerosol mass was made up on average of 35(±4)% of organic matter (OM) in the PM10 fraction, while the contribution of OM to the PM2.5 mass was 43(±9)%. At the background, OM also accounted for 43(±13)% of the PM2.0 mass. On average, EC made up 14(±6)%, 7(±2)% and 4.5(±1.1)% of the mass in the PM2.5, PM10 fractions and TSP, respectively, at the kerbside; while its contribution was only 2.1(±0.5)% in the PM2.0 fraction in the near-city background. Temporal variability for PM mass, OC and EC concentrations was related to road traffic, local meteorology and long-range transport of air masses. It was concluded that a direct coupling between the atmospheric concentration levels and vehicle circulation can be identified within the urban canyon, nevertheless, the local meteorology in particular and long-range transport of air masses have much more influence on the air quality than changes in the source intensity of road traffic. Concentration ratios of OC/EC were evaluated, and the amount of secondary organic aerosol (SOA) was estimated by using EC as tracer for the primary OC emissions. Mean contribution and standard deviation of the SOA to the OM in the PM2.5 size fraction at the kerbside over daylight periods and nights were of 37(±18) and 46(±16)%, respectively.  相似文献   

3.
Outdoor and indoor fine particulate species were measured at the Lindon Elementary School in Lindon, Utah, to determine which components of ambient fine particles have strong indoor and outdoor concentration correlations. PM2.5 mass concentrations were measured using tapered element oscillating microbalance (TEOM) monitors and by gravimetric analysis of Teflon filter samples. Gas-phase HNO3, sulfur dioxide, particulate nitrate, strong acid, and particulate sulfate were measured using annular denuder samplers. Soot was measured using quartz filters in filter packs. Total particulate number was measured with a condensation nucleus counter (CNC). Total particulate number and fine particulate sulfate and soot were correlated for ambient and indoor measurements. Indoor PM2.5 mass showed a low correlation with outdoor PM2.5 mass because of the influence of coarse material from student activities on indoor PM2.5. Fine particle acidity and the potentiation of biological oxidative mechanisms by iron were not correlated indoors and outdoors.  相似文献   

4.
The Monterrey Metropolitan Area (MMA) has shown a high concentration of PM2.5 in its atmosphere since 2003. The contribution of possible sources of primary PM2.5 and its precursors is not known. In this paper we present the results of analyzing the chemical composition of sixty 24-hr samples of PM2.5 to determine possible sources of PM2.5 in the MMA. The samples were collected at the northeast and southeast of the MMA between November 22 and December 12, 2007, using low-volume devices. Teflon and quartz filters were used to collect the samples. The concentrations of 16 airborne trace elements were determined using x-ray fluorescence (XRF). Anions and cations were determined using ion chromatography. Organic carbon (OC) and elemental carbon (EC) were determined by thermal optical analysis. The results show that Ca had the maximum mean concentration of all elements studied, followed by S. Enrichment factors above 50 were calculated for S, Cl, Cu, Zn, Br and Pb. This indicates that these elements may come from anthropogenic sources. Overall, the major average components of PM2.5 were OC (41.7%), SO4(2-) (22.9%), EC (7.4%), crustal material (11.4%), and NO3- (12.6%), which altogether accounted for 96% of the mass. Statistically, we did not find any difference in SO4(2-) concentrations between the two sites. The fraction of secondary organic carbon was between 24% and 34%. The results of the factor analysis performed over 10 metals and OC and EC show that there are three main sources of PM2.5: crustal material and vehicle exhaust; industrial activity; and fuel oil burning. The results show that SO4(2-), OC, and crustal material are important components of PM2.5 in MMA. Further work is necessary to evaluate the proportion of secondary inorganic and organic aerosol in order to have a better understanding of the sources and precursors of aerosols in the MMA.  相似文献   

5.
Daily particle samples were collected in Chillán, Chile, at six urban locations from September 1, 2001, through September 30, 2003. Aerosol samples were collected using monitors equipped with a Sierra Andersen 246-b cyclone inlet on Teflon filters. Average concentrations of coarse particulate matter (PM10) for the 2001-2003 period ranged from 43.4 microg/m3 to 81.8 microg/m3 across the six sites. Annual PM10 concentration levels exceeded the European Union concentration limits. Mean PM10 levels during the cold season (April through September) were more than twice as high as those observed in the warm season (October through March). Average contributions to PM10 from organic matter, soil dust, nitrate (NO3-), elemental carbon, ammonium (NH4+), and sulfate (SO4(2-)) were 31%, 27%, 11%, 8%, 7%, and 5%, respectively. The chemical analyses indicated that carbonaceous substances were the most abundant components of PM10 in cold months, whereas crustal material was the most abundant component of PM10 during warm months. Higher concentration levels were observed in the downtown area suggesting a clear anthropogenic origin, whereas in the rural sites the source was mainly natural, such as resuspended soil dust associated with traffic on unpaved roads and agricultural activities.  相似文献   

6.
During collection on filter-based aerosol samplers, organic and inorganic aerosol compounds both contribute to positive and negative artefacts, significantly affecting chemical analyses results for single species and PM mass concentrations. Up to now, studies on organic or inorganic artefacts have been conducted in Europe but very scarce data are available for both in a single study.The field study was carried out in Milan, which is located in the Po valley (Northern Italy) one of the major pollution hot spots in Europe. As sampling artefacts depend on many factors, such as filter type, face velocity, sampling duration, and ambient conditions, in this field study two different filter types have been considered (i.e. quartz fibre filters and Teflon filters) for the assessment of both inorganic and organic artefacts during two different seasons (performing also some samplings at different flow-rates).Results showed that positive artefacts due to OC adsorption on quartz filters accounted for 39% of the OC measured concentration in summer, and 23% in winter. Negative artefact due to nitrate volatilisation by the filters was 51% on Teflon and 22% on the quartz filters in summer, and no or negligible losses were observed in winter. A significant improvement in the PM mass comparability obtained in parallel samplings on different filters was obtained taking into account the artefact estimates performed in this study.  相似文献   

7.
Fang GC  Chang CN  Wang NP  Wu YS  Wang V  Fu PP  Cheng CD  Chen SC  Lin DY 《Chemosphere》2000,41(11):1727-1731
Ambient particle concentration was taken on the traffic sampling site over the Chung-Chi Road over bridge (CCROB) in front of Hungkuang Institute of Technology (HKIT). The sampling time was from August 1999 to December 1999. During the sampling period, Taiwan's biggest earthquake in more than a century registered 7.3 on the Richter scale (Taiwan Chi-Chi Earthquake). Besides, there were more than 20,000 aftershocks that followed the Taiwan Chi-Chi Earthquake within three months. Thus, the PM2.5, PM(2.5-10) particle concentrations were also collected then and compared with total suspended particle (TSP) in this study. The average PM(2.5-10), PM2.5 and TSP concentrations are 24.6, 58.0 and 106 microg/m3, respectively, after the Taiwan Chi-Chi Earthquake. The average TSP concentrations before and after Taiwan Chi-Chi Earthquake were 70 and 127 microg/m3, respectively. It is clearly shown that the average concentration of TSP after Taiwan Chi-Chi Earthquake was about 1.8 times as that of TSP concentration before Taiwan Chi-Chi Earthquake in the traffic site of central Taiwan. And the ratios of PM2.5/PM(2.5-10), PM2.5/PM10 and PM2.5/TSP are 2.2%, 67.2%, 38.9%, respectively. The results also indicated about Chi-Chi fine particle concentration (PM25) and the TSP increases in the traffic site of central Taiwan after Taiwan Chi-Chi Earthquake.  相似文献   

8.
The extent of mass loss on Teflon filters caused by ammonium nitrate volatilization can be a substantial fraction of the measured particulate matter with an aerodynamic diameter less than 2.5 microm (PM2.5) or 10 microm (PM10) mass and depends on where and when it was collected. There is no straightforward method to correct for the mass loss using routine monitoring data. In southern California during the California Acid Deposition Monitoring Program, 30-40% of the gravimetric PM2.5 mass was lost during summer daytime. Lower mass losses occurred at more remote locations. The estimated potential mass loss in the Interagency Monitoring of Protected Visual Environments network was consistent with the measured loss observed in California. The biased mass measurement implies that use of Federal Reference Method data for fine particles may lead to control strategies that are biased toward sources of fugitive dust, other primary particle emission sources, and stable secondary particles (e.g., sulfates). This analysis clearly supports the need for speciated analysis of samples collected in a manner that preserves volatile species. Finally, although there is loss of volatile nitrate (NO3-) from Teflon filters during sampling, the NO3- remaining after collection is quite stable. We found little loss of NO3- from Teflon filters after 2 hr under vacuum and 1 min of heating by a cyclotron proton beam.  相似文献   

9.
This paper presents and discusses the results obtained from the gravimetric and chemical analyses of the 24-hr average dichotomous samples collected from five sites in the El Paso-Cd. Juarez air quality basin between August 1999 and March 2000. Gravimetric analysis was performed to determine the temporal and spatial variations of PM2.5 (particulate matter less than 2.5 microm in diameter) and PM25-10 (particulate matter less than 10 pm but greater than 2.5 microm in diameter) mass concentrations. The results indicate that approximately 25% of the PM10 (i.e., PM25 + PM25-10) concentration is composed of PM2.5. Concurrent measurements of hourly PM concentrations and wind speed showed strong diurnal patterns of the regional PM pollution. Results of X-ray fluorescence (XRF) elemental analyses were compared to similar but limited studies performed by the Texas Natural Resource Conservation Commission (TNRCC) in 1990 and 1997. Major elements from geologic sources-Al, Si, Ca, Na, K, Fe, and Ti-accounted for 35% of the total mass concentrations in the PM2.5-10 fraction, indicating that geologic sources in the area are the dominant PM sources. Levels of toxic trace elements, mainly considered as products of anthropogenic activities, have decreased significantly from those observed in 1990 and 1997.  相似文献   

10.
INTENTION, GOAL, SCOPE, BACKGROUND: As the strong negative health effect of exposure to the inhalable particulate matter PM10 in the urban environment has been confirmed, the study of the mass concentrations, physico-chemical characteristics, sources, as well as spatial and temporal variation of atmospheric aerosol particles becomes very important. OBJECTIVE: This work is a pilot study to assess the concentration level of ambient suspended particulate matter, with an aerodynamic diameter of less than 10 microm, in the Belgrade central urban area. Average daily concentrations of PM10 and PM2.5 have been measured at three representative points in the city between June 2002 and December 2002. The influence of meteorological parameters on PM10 and PM2.5 concentrations was analyzed, and possible pollution sources were identified. METHODS: Suspended particles were collected on Pure Teflon filters by using a Mini-Vol low-volume air sampler (Airmetrics Co., Inc.; 5 l min(-1) flow rate). Particle mass was determined gravimetrically after 48 h of conditioning in a desiccator, in a Class 100 clean room at the temperature T = 20 degrees C and at about 50% constant relative humidity (RH). RESULTS AND DISCUSSION: Analysis of the PM10 data indicated a marked difference between season without heating--(summer; mean value 56 microg m(-3)) and heating season--(winter; mean value 96 microg m3); 62% of samples exceeded the level of 50 microg m(-3). The impact of meteorological factors on PM concentrations was not immediately apparent, but there was a significant negative correlation with the wind speed. CONCLUSIONS: The PM10 and PM2.5 mass concentrations in the Belgrade urban area had high average values (77 microg m(-3) and 61 microg m(-3)) in comparison with other European cities. The main sources of particulate matter were traffic emission, road dust resuspension, and individual heating emissions. When the air masses are coming from the SW direction, the contribution from the Obrenovac power plants is evident. During days of exceptionally severe pollution, in both summer and winter periods, high production of secondary aerosols occurred, as can be seen from an increase in PM2.5 in respect to PM10 mass concentration. RECOMMENDATION AND OUTLOOK: The results obtained gave us the first impression of the concentration level of particulate matter, with an aerodynamic diameter of less than 10 microm, in the Belgrade ambient air. Due to measured high PM mass concentrations, it is obvious that it would be very difficult to meet the EU standards (EEC 1999) by 2010. It is necessary to continue with PM10 and PM2.5 sampling; and after comprehensive analysis which includes the results of chemical and physical characterization of particles, we will be able to recommend effective control measures in order to improve air quality in Belgrade.  相似文献   

11.
ABSTRACT

This paper presents and discusses the results obtained from the gravimetric and chemical analyses of the 24-hr average dichotomous samples collected from five sites in the El Paso-Cd. Juarez air quality basin between August 1999 and March 2000. Gravimetric analysis was performed to determine the temporal and spatial variations of PM2.5 (particulate matter less than 2.5 um in diameter) and PM2.5-10 (particulate matter less than 10 μm but greater than 2.5 μm in diameter) mass concentrations. The results indicate that ~25% of the PM10 (i.e., PM2.5 + PM2.5-10) concentration is composed of PM2.5. Concurrent measurements of hourly PM concentrations and wind speed showed strong diurnal patterns of the regional PM pollution. Results of X-ray fluorescence (XRF) elemental analyses were compared to similar but limited studies performed by the Texas Natural Resource Conservation Commission (TNRCC) in 1990 and 1997. Major elements from geologic sources—Al, Si, Ca, Na, K, Fe, and Ti—accounted for 35% of the total mass concentrations in the PM2.5-10 fraction, indicating that geologic sources in the area are the dominant PM sources. Levels of toxic trace elements, mainly considered as products of anthropogenic activities, have decreased significantly from those observed in 1990 and 1997.  相似文献   

12.
The Maryland State Highway Administration (SHA) monitoring program monitored the impact of vehicular emissions on the concentrations of the fine particles smaller than 2.5 microns (PM2.5). PM2.5 concentrations were monitored in close proximity to a highway in order to determine whether traffic conditions on the roadway impact concentrations at this location. The monitoring program attempted to connect monitored concentrations with the roadway traffic exhaust or with the other sources of PM2.5. PM2.5 concentrations were collected near the Capital Beltway (I-495/I-95) in Largo, Maryland. The monitoring program was launched on May 13, 2009 and continued through the end of 2012. Two co-located monitors, one for continuous PM2.5 measurements and the other for speciation measurements, were used in this program. Meteorological and traffic information was also continuously collected at or near the monitoring site. Additionally, data from the two other monitoring locations, one at the Howard University-Beltsville, MD and one at McMillan Reservoir, DC, was used for comparison with the data collected at the SHA monitoring location. The samples collected by the speciation monitor were analyzed at the RTI and DRI Laboratories to determine the composition and the sources of the collected PM2.5 samples. Based on the apportionment analysis, the contribution of roadway sources is about 12 to 17 percent of PM2.5 at the near-road site.

Implications: PM2.5 monitoring at 150 m (approximately 500 feet) from a major highway in Maryland near Washington, DC, demonstrated that roadway traffic contributes to the total PM2.5 concentration near the roadway, but the contribution at such distance is small, in the order of 12–17% of the total.  相似文献   

13.
Two semicontinuous elemental and organic carbon analyzers along with daily integrated samplers, which were used for laboratory elemental and organic carbon analysis, were operated to measure PM2.5 organic carbon (OC) and elemental carbon (EC) for the entire year of 2002 at the St. Louis Midwest Supersite. The annual-average denuded OC and EC concentrations were 3.88 and 0.7 microg/m3, respectively. A comparison of the 24-hr average denuded and undenuded OC measurements showed a positive bias for the undenuded OC measurement that was best represented by a positive intercept of 0.34 +/- 0.1 microg/m3 and a slope of 1.06 +/- 0.02, with an R2 of 0.91. The full year of daily EC and OC measurements was used to demonstrate that a one-in-six-day sampling strategy at this site accurately represents the annual average concentrations. Although fine particle OC concentrations did not correlate with day of the week, EC concentrations showed a significant weekly pattern, with the highest concentration during the middle of the workweek and the lowest concentration on Sundays. Hourly EC and OC measurements yielded average diurnal patterns for the EC to OC ratio that peaked during morning rush hour traffic on weekdays but not on weekends.  相似文献   

14.
ABSTRACT

Several recent studies have shown associations between ambient concentrations of particle mass (PM) and rates of morbidity and mortality in the general population. These studies have raised the issue of quality of coarse mass (CM, PM between 2.5 and 10 µm) data used for these purposes. CM data may have precision three or more times worse than the associated PM 2.5 or PM10 data, depending on the measurement method, PM 2.5 to PM 10 ratios, and CM concentrations. CM is measured either as the difference between collocated PM10 and PM2.5 samplers or more directly with a dichotomous (virtual impactor) sampler. CM precision for the difference method is degraded due to the increased errors inherent with using the difference between two independent measurements, as well as the high PM2.5 to PM10 ratios (and low CM concentrations) typical of the eastern United States. The dichotomous sampler (dichot) makes a more direct measurement of CM, but there is a potential for significant postexposure loss of particles from unoiled CM dichot filters, as well as uncertainties in the dichot’s CM channel enrichment factor. Compared to the dichot, low-volume inertial impactor samplers such as the Harvard Impactor (HI) or PM2.5 Federal Reference Method (FRM) are simpler to operate and maintain, provide sharper cut points, and do not require oiled filters to prevent loss of CM from the filter during transport. With the recent interest in CM spatial and temporal variability with respect to PM health effects, we have developed modifications to the HI PM method to provide measurements of 24-hour PM with estimated CM precision of better than 5% CV and r2 higher than 0.95, primarily by lowering field blank variability and increasing gravimetric analytical precision. These high-precision PM techniques are not limited to the HI sampler; they can also be applied to the PM2.5 FRM sampler. The measurement methods described here can be applied to future PM studies to avoid the potential problems with exposure assessment caused by CM measurements that have poor precision.  相似文献   

15.
We developed and tested a methodology to extract both the size-segregated source apportionment of atmospheric aerosol and the size distribution of each detected element. The experiment is based on the parallel use of a standard low-volume sampler to collect Particulate Matter (PM) and an Optical Particle Counter (OPC). The approach is complementary to size-segregated PM sampling, and it was tested versus a 12-stage cascade impactor. Samples were collected inside the urban area of Genoa (Italy) and their elemental composition was measured by Energy Dispersive-X Ray Fluorescence (ED-XRF). Positive Matrix Factorization (PMF) was applied to time series of elemental concentrations to identify major PM sources, and both PM mass concentration and size-segregated particle number concentration were apportioned. Source profiles and temporal trends extracted by PMF were analyzed together with the OPC data to obtain the size distribution for several elements. The new methodology proved to be reliable for the PM apportionment as well as in providing the elemental concentrations in PM10, PM2.5, and PM1 (PM with aerodynamic diameter, Dae < 10, 2.5, and 1 μm, respectively). The elemental size distributions are in good agreement with those obtained by the cascade impactor for several elements but some discrepancies, in particular for traffic emissions, are stressed and discussed in the text. The new methodology has two main advantages: it only requires standard semi-automatic sampling equipment and compositional analysis and it provides size-segregated information averaged over quite long periods (typically several months). This is particularly important since campaigns with cascade impactors are generally laborious and thus limited to short periods.  相似文献   

16.
In December 1994, the South Coast Air Quality Management District (SCAQMD) initiated a comprehensive program, the PM10 Technical Enhancement Program (PTEP), to characterize fine PM in the South Coast Air Basin (SCAB). A 1-year special particulate monitoring project was conducted from January 1995 to February 1996 as part of the PTEP. Under this enhanced monitoring, HNO3, NH3, and speciated PM10 and PM2.5 concentrations were measured at five stations (Anaheim, downtown Los Angeles, Diamond Bar, Fontana, and Rubidoux) in the SCAB and at one background station at San Nicolas Island. PM2.5 and PM10 mass and 43 individual species were analyzed for a full chemical speciation of the particle data. The PTEP data indicate that the most abundant chemical components of PM10 and PM2.5 in the SCAB are NH4+ (8-9% of PM10 and 14-17% of PM2.5), NO3- (23-26% of PM10 and 28-41% of PM2.5), SO4- (6-11% of PM10 and 9-18% of PM2.5), organic carbon (OC) (15-19% of PM10 and 18-26% of PM2.5), and elemental carbon (EC) (5-8% of PM10 and 8-13% of PM2.5). On an annual average basis, PM2.5 comprises 52-59% of the SCAB PM10. Annual average PM10 and PM2.5 concentrations showed strong spatial variations, low at coastal sites and high at inland sites. Annual average PM10 concentrations varied from 40.8 micrograms/m3 at Anaheim to 76.8 micrograms/m3 at Rubidoux, while annual average PM2.5 concentrations varied from 21.7 micrograms/m3 at Anaheim to 39.8 micrograms/m3 at Rubidoux. The chemical characterizations of the PM2.5 and PM10 concentrations, as well as their spatial variations, were examined; the important findings are summarized in this paper, and the temporal variations are discussed in the companion paper.  相似文献   

17.
Taking advantage of the continuous spatial coverage, satellite-derived aerosol optical depth (AOD) products have been widely used to assess the spatial and temporal characteristics of fine particulate matter (PM2.5) on the ground and their effects on human health. However, the national-scale ground-level PM2.5 estimation is still very limited because the lack of ground PM2.5 measurements to calibrate the model in China. In this study, a national-scale geographically weighted regression (GWR) model was developed to estimate ground-level PM2.5 concentration based on satellite AODs, newly released national-wide hourly PM2.5 concentrations, and meteorological parameters. The results showed good agreements between satellite-retrieved and ground-observed PM2.5 concentration at 943 stations in China. The overall cross-validation (CV) R 2 is 0.76 and root mean squared prediction error (RMSE) is 22.26 μg/m3 for MODIS-derived AOD. The MISR-derived AOD also exhibits comparable performance with a CV R 2 and RMSE are 0.81 and 27.46 μg/m3, respectively. Annual PM2.5 concentrations retrieved either by MODIS or MISR AOD indicated that most of the residential community areas exceeded the new annual Chinese PM2.5 National Standard level 2. These results suggest that this approach is useful for estimating large-scale ground-level PM2.5 distributions especially for the regions without PMs monitoring sites.  相似文献   

18.
Recent studies have used land use regression (LUR) techniques to explain spatial variability in exposures to PM2.5 and traffic-related pollutants. Factor analysis has been used to determine source contributions to measured concentrations. Few studies have combined these methods, however, to construct and explain latent source effects. In this study, we derive latent source factors using confirmatory factor analysis constrained to non-negative loadings, and develop LUR models to predict the influence of outdoor sources on latent source factors using GIS-based measures of traffic and other local sources, central site monitoring data, and meteorology. We collected 3–4 day samples of nitrogen dioxide (NO2) and PM2.5 outside of 44 homes in summer and winter, from 2003 to 2005 in and around Boston, Massachusetts. Reflectance analysis, X-ray fluorescence spectroscopy (XRF), and high-resolution inductively-coupled plasma mass spectrometry (ICP-MS) were performed on particle filters to estimate elemental carbon (EC), trace element, and water-soluble metals concentrations. Within our constrained factor analysis, a five-factor model was optimal, balancing statistical robustness and physical interpretability. This model produced loadings indicating long-range transport, brake wear/traffic exhaust, diesel exhaust, fuel oil combustion, and resuspended road dust. LUR models largely corroborated factor interpretations through covariate significance. For example, ‘long-range transport’ was predicted by central site PM2.5 and season; ‘brake wear/traffic exhaust’ and ‘resuspended road dust’ by traffic and residential density; ‘diesel exhaust’ by percent diesel traffic on nearest major road; and ‘fuel oil combustion’ by population density. Results suggest that outdoor residential PM2.5 source contributions can be partially predicted using GIS-based terms, and that LUR techniques can support factor interpretation for source apportionment. Together, LUR and factor analysis facilitate source identification, assessment of spatial and temporal variability, and more refined source exposure assignment for evaluation of source contributions to health outcomes in epidemiological studies.  相似文献   

19.
Absorption of sunlight by sub-micron particles is an important factor in calculations of the radiation balance of the earth and thus in climate modelling. Carbon-containing particles are generally considered as the most important in this respect. Major sources of these particles are generally considered to be bio-mass burning and vehicle exhaust. In order to characterise size fractionated particulate matter in a rural village in Botswana with respect to light absorption and elemental content experiments were performed, in which simultaneous sampling was made with a dichotomous impactor and a laboratory-made sampler, made compatible with black carbon analysis by reflectometry. The dichotomous impactor was equipped with Teflon filters and the other sampler with glass fibre filters. Energy dispersive X-ray fluorescence was used for elemental analysis of both kinds of filters. It appeared that Teflon filters were the most suitable for the combination of mass-, elemental- and black carbon measurements. The black carbon content in coarse (2.5–10 μm) and fine (<2.5 μm) particles was determined separately and related to elemental content and emission source. The results show that the fine particle fraction in the aerosol has a much higher contribution of black particles than the coarse particle fraction. This observation is valid for the village in Botswana as well as for a typical industrialised city in Sweden, used as a reference location.  相似文献   

20.
The associations between residential outdoor and ambient particle mass, fine particle absorbance, particle number (PN) concentrations, and residential and traffic determinants were investigated in four European urban areas (Helsinki, Athens, Amsterdam, and Birmingham). A total of 152 nonsmoking participants with respiratory diseases, not exposed to occupational pollution, were included in the study, which comprised a 7-day intensive exposure monitoring period of both indoor and home outdoor particle mass and number concentrations. The same pollutants were also continuously measured at ambient fixed sites centrally located to the studied areas (fixed ambient sites). Relationships between concentrations measured directly outside the homes (residential outdoor) and at the fixed ambient sites were pollutant-specific, with substantial variations among the urban areas. Differences were more pronounced for coarse particles due to resuspension of road dust and PN, which is strongly related to traffic emissions. Less significant outdoor-to-fixed variation for particle mass was observed for Amsterdam and Birmingham, predominantly due to regional secondary aerosol. On the contrary, a strong spatial variation was observed for Athens and to a lesser extent for Helsinki. This was attributed to the overwhelming and time-varied inputs from traffic and other local sources. The location of the residence and traffic volume and distance to street and traffic light were important determinants of residential outdoor particle concentrations. On average, particle mass levels in suburban areas were less than 30% of those measured for residences located in the city center. Residences located less than 10 m from a street experienced 133% higher PN concentrations than residences located further away. Overall, the findings of this multi-city study, indicated that (1) spatial variation was larger for PN than for fine particulate matter (PM) mass and varied between the cities, (2) vehicular emissions in the residential street and location in the center of the city were significant predictors of spatial variation, and (3) the impact of traffic and location in the city was much larger for PN than for fine particle mass.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号