首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this work we present the results of a 2-year survey of indoor radon variations in four cities of Lahijan, Ardabil, Sar-Ein and Namin in North and Northwest Iran. We used both passive and active measurements by solid state nuclear track detectors (SSNTDs) with CR-39 polycarbonate and PRASSI Portable radon Gas Surveyor. A total of 1124 samplers in Lahijan, Ardabil, Sar-Ein and Namin were installed. Sampling frequency was seasonal and sampling locations were randomly chosen based on dwelling structures, floors, geological formations, elevation and temperature variation parameters. For quality assurance, 281 active measurements and double sampling were carried out. Based on our results and the results of previous surveys, Ardabil and Lahijan have the second and third highest radon concentration in Iran, respectively (Ramsar is first). The average radon concentration during the year in Lahijan, Ardabil, Sar-Ein and Namin were 163, 240, 160 and 144 Bq/m(3) with medians of 160, 168, 124 and 133 Bq/m(3), respectively. These concentrations give rise to annual effective doses of 3.43 mSv/y for Lahijan and 5.00 mSv/y for Ardabil. The maximum recorded concentration was 2386 Bq/m(3) during winter in Ardabil and the minimum concentration was 55 Bq/m(3) during spring in Lahijan. Relationships between radon concentration and building materials and room ventilation were also studied. The dosimetry calculations showed that these four cities could be categorized as average natural radiation zones. The correlation coefficients relating warm and cold season radon variation data were obtained.  相似文献   

2.
Measurements of indoor radon concentrations were performed in 28 low-rise houses and 30 apartments in Patras area from December 1996 to November 1997, using nuclear track detectors. The investigation was focused on the effects of season and floor number, as well as on the existence of a basement in low-rise houses on indoor radon levels. It was found that the differences in mean radon concentrations between adjacent seasons, in a number of 61 selected sampling sites distributed in 28 houses, were statistically significant. As expected, a maximum was found in winter and a minimum in summer. The differences in mean radon concentration on different floors of the same houses were also statistically significant and followed a linear decrease from underground to 2nd floor. In addition, indoor radon concentrations in the ground floor were found to be influenced by the existence or not of a basement. The average annual radon concentration was found to be 41 Bq m(-3) for the houses, 28 Bq m(-3) for the apartments and 38 Bq m(-3) for all the dwellings. These values lead to an average effective dose equivalent of 1.1, 0.7 and 0.9 mSv y(-1), respectively. Residents living on the underground in low-rise houses, during winter, where the average effective dose equivalent is 2.1 mSv y(-1), attain the higher risk.  相似文献   

3.
Specific activities of the natural radionuclides (238)U, (226)Ra, (232)Th and (40)K were measured by means of gamma-ray spectrometry in surface soil samples collected from the city of Ptolemais, which is located near lignite-fired power plants. The mean activity values for (238)U, (226)Ra, (232)Th and (40)K were found to be 42+/-11, 27+/-6, 36+/-5 and 496+/-56 Bq kg(-1), respectively. These values fall within the range of typical world and Greek values for soil. The indoor radon concentration levels, which were also measured in 66 dwellings by means of SSNTD, ranged from 12 to 129 Bq m(-3), with an average value of 36+/-2 Bq m(-3). This value is close to world and Greek average values for indoor radon concentrations. The total effective dose due to outdoor external irradiation of terrestrial origin and to indoor internal irradiation from the short-lived decay products of (222)Rn was estimated to be 1.2 mSv y(-1) for adults, which is lower than the global effective dose due to natural sources of 2.4 mSv y(-1).  相似文献   

4.
To quantify the effectiveness of Sub-Slab Depressurisation, widely used in the United Kingdom (U.K.) to mitigate indoor radon gas levels in residential properties, a study was made of radon concentration data collected from a set of 170 homes situated in Radon Affected Areas in Northamptonshire and neighbouring counties, remediated using conventional sump/pump technology. A high incidence of satisfactory remediation outcomes was achieved, with 100% of the houses remediated demonstrating post-remediation radon concentrations below the U.K. domestic Action Level of 200 Bq m(-3), while more than 75% of the sample exhibited radon mitigation factors (defined as the ratio of radon concentrations following and prior to remediation) <0.2. Two systematic trends are identified. Firstly, absolute radon concentration reduction following remediation is directly proportional to initial radon concentration, with a mean reduction factor of 0.96 and a residual component of around 75 Bq m(-3). Secondly, houses with lower initial radon concentrations demonstrate poorer (higher) mitigation factors. These observations support a model in which the total indoor radon concentration within a dwelling can be represented by two principal components, one susceptible to mitigation by sub-slab depressurisation, the other remaining essentially unaffected. The first component can be identified with radon emanating from the subsoil and bedrock geologies, percolating through the foundations of the dwelling as a component of the soil-gas, and potentially capable of being attenuated by sub-slab depressurisation or radon-barrier remediation technologies. The second contribution can be identified with radon emanating from materials used in the construction of the dwelling with a further contribution from the natural background level, and is essentially unaffected by ground-level remediation strategies. Modelling of a multi-component radon dependency using ground-radon attenuation factors derived from the experimental data, in conjunction with typical background and structural-radon levels, yields behaviour in good agreement with the observed dependence of mitigation factor on initial radon concentration.  相似文献   

5.
Using high-sensitivity radon ((222)Rn) portable detectors (passive electronic devices of the type RADIM3), the airborne (222)Rn concentration in the interior of various Cypriot buildings and dwellings was measured. For each preselected building and dwelling, a calibrated detector was put into a closed room, and the (222)Rn concentration was registered in sampling intervals of 2 to 4 h for a total counting time of typically 48 h. (222)Rn activity concentrations were found to be in the range of 6.2 to 102.8 Bq m(-3), with an overall arithmetic mean value of (19.3+/-14.7) Bq m(-3). This value is by a factor of two below the world average (population-weighted) value of 39 Bq m(-3). The total annual effective dose equivalent to the Cypriot population was calculated to be between 0.16 and 2.6 mSv with an overall arithmetic mean value of (0.49+/-0.37) mSv.  相似文献   

6.
Radon (Rn(222)) levels in an indoor atmosphere of a multi-storey building at Mumbai have been measured for one year covering all the four seasons. Monitoring was carried out using the time-integrated passive detector technique, using Kodak-115 type Solid State Nuclear Track Detector (SSNTD) films of 2.5x2.5 cm size. Measured indoor radon levels showed a decreasing trend with height with concentration ranging from 41 Bq m(-3) at ground floor level to 15 Bq m(-3) at 19th floor level. Using the dose conversion factors, the inhalation dose due to breathing of radon gas is estimated to be 1.03 mSv y(-1) at the ground floor to 0.38 mSv y(-1) at the 19th floor level. Measured indoor radon concentrations on each floor were compared with the computed values using a mathematical model. The agreement between measured values and calculated values of indoor concentrations at different floors was very good within the limitations of various field parameter values.  相似文献   

7.
Coal and its by products often contain significant amounts of radionuclides, including uranium which is the ultimate source of the radioactive gas radon. Burning of coal and the subsequent emission to the atmosphere cause the re-distribution of toxic trace elements in the environment. Due to considerable economic and environmental importance and diverse uses, the collected fly ash has become a subject of worldwide interest in recent years. In the present study, radon exhalation rate and the activity concentration of (238)U, (232)Th and (40)K radionuclides in fly ash samples from Durgapur thermal power plant (WB) have been measured by "Sealed Can technique" using LR-115 type II detectors and a low level NaI (Tl) based gamma ray spectrometer, respectively. Radon exhalation rate varied from 360.0 to 470.0 mBq m(-2)h(-1) with an average value of 406.8 mBq m(-2)h(-1). Activity concentrations of (238)U ranged from 84.8 to 126.4 Bq kg(-1) with an average value of 99.3Bqkg(-1), (232)Th ranged from 98.1 to 140.5 Bq kg(-1) with an average value of 112.9 Bq kg(-1) and (40)K ranged from 267.1 to 364.9 Bq kg(-1) with an average value of 308.9 Bq kg(-1). Radium equivalent activity obtained from activity concentrations is found to vary from 256.5 to 352.8 Bq kg(-1) with an average value of 282.5 Bq kg(-1). Absorbed gamma dose rates due to the presence of (238)U, (232)Th and (40)K in fly ash samples vary in the range 115.3-158.5 nGy h(-1) with an average value of 126.4 nGy h(-1). While the external annual effective dose rate varies from 0.14 to 0.19 mSv y(-1) with an average value of 0.15 mSv y(-1), effective dose equivalent estimated from exhalation rate varies from 42.5 to 55.2 microSv y(-1) with an average value of 47.8 microSv y(-1). Values of external hazard index H(ex) for the fly ash samples studied in this work range from 0.69 to 0.96 with a mean value of 0.77.  相似文献   

8.
Radon levels in atmospheric and aquatic systems in Cyprus have recently been measured using the radon monitor Alpha Guard. Indoor and outdoor radon levels were obtained in situ, whereas analysis of radon concentrations in water was performed using tap and ground water samples collected from several areas of the island. The average value for outdoor and indoor radon concentration is 11+/-10 and 7+/-6 Bq m(-3), respectively, and for tap and ground water 0.4 Bq l(-1) and 1.4 Bq l(-1), respectively. From these data the annual dose equivalent of airborne radon to the Cypriot population is about 0.19 mSv y(-1), which is quite low compared to the total dose equivalent of natural and man-made ionising radiation in Cyprus. Radon levels in aquatic systems are relatively low due to an exhaustive utilisation of ground water resources and also to the increased input of desalinated sea water in the water distribution network and eventually into the ground water reservoirs.  相似文献   

9.
The results of a survey of outdoor radon concentrations in Milan are reported. Measurements were performed hourly over a continuous four year period from January 1997 to December 2000. Radon concentration was obtained by two means: both direct measurement of radon; and measurement of its decay products. The average daily pattern of radon concentration featured a minimum in the late afternoon and a maximum in the early hours of the morning. A seasonal pattern with higher concentrations in winter than in summer (from around 15 Bq m(-3) in winter to around 5 Bq m(-3) in summer) was also observed. Similar average annual values of around 10 Bq m(-3) were obtained. The annual effective outdoor radon dose was found to be 0.12 mSv. The variation from minimum in the afternoon to maximum the following morning was found to be a good indicator of the height of the nocturnal mixing layer. The variation between maximum and minimum levels on the same day is an index of the maximum height of the mixing layer. Furthermore, our long term measurements of radon have permitted us to examine the dispersion characteristics of the atmosphere over Milan, and to establish the frequency of conditions unfavourable to the dispersion of atmospheric pollutants.  相似文献   

10.
An investigation of radon levels in the caves of Creswell Crags, Derbyshire, an important Site of Special Scientific Interest (SSSI) shows that the Lower Magnesian Limestone (Permian) caves have moderate to raised radon gas levels (27-7800 Bq m(-3)) which generally increase with increasing distance into the caves from the entrance regions. This feature is partly explained in terms of cave ventilation and topography. While these levels are generally below the Action Level in the workplace (400 Bq m(-3) in the UK), they are above the Action Level for domestic properties (200 Bq m(-3)). Creswell Crags has approximately 40,000 visitors per year and therefore a quantification of effective dose is important for both visitors and guides to the Robin Hood show cave. Due to short exposure times the dose received by visitors is low (0.0016 mSv/visit) and regulations concerning exposure are not contravened. Similarly, the dose received by guides is fairly low (0.4 mSv/annum) due in part to current working practice. However, the risk to researchers entering the more inaccessible areas of the cave system is higher (0.06 mSv/visit). This survey also investigated the effect of seasonal variations on recorded radon concentration. From this work summer to winter ratios of between 1.1 and 9.51 were determined for different locations within the largest cave system.  相似文献   

11.
High-resolution gamma spectrometry was used to determine the concentration of 40K, 238U and 232Th series in soil samples taken from areas surrounding the city of Aldama, in Chihuahua. Results of indoor air short-time sampling, with diffusion barrier charcoal detectors, revealed relatively high indoor radon levels, ranging from 29 to 422 Bq/m3; the radon concentrations detected exceeded 148 Bq/m3 in 76% of the homes tested. Additionally, liquid scintillation counting showed concentrations of radon in drinking water ranging from 4.3 to 42 kBq/m3. The high activity of 238U in soil found in some places may be a result of the uranium milling process performed 20 years ago in the area. High radon concentrations indoor and in water may be explained by assuming the presence of uranium-bearing rocks underneath of the city, similar to a felsic dike located near Aldama. The estimated annual effective dose of gamma radiation from the soil and radon inhalation was 3.83 mSv.  相似文献   

12.
Radon ((222)Rn) concentration was measured at indoor workplaces in Japan to estimate effective dose to the public from (222)Rn and its progeny. Measurements were made from 2000 to 2003 at 705 sites in four categories of office, factory, school and hospital. Passive type Rn monitors equipped with two sheets of polycarbonate thin films for measuring radon concentrations were installed at observation sites and replaced every 3 months to observe seasonal variations in (222)Rn concentrations. The range of annual mean (222)Rn concentrations for all sites was 1.4-182 Bq m(-3), with the arithmetic mean and standard deviation were 20.8 and 19.5 Bq m(-3). Annual mean (222)Rn concentration observed at office, factory, school and hospital were 22.6, 10.1, 28.4 and 19.8 Bq m(-3), respectively. Seasonal variations in (222)Rn concentrations at offices, schools and hospitals were similar to those found in dwellings, and variations in factories were similar to those found in outdoor environments. (222)Rn concentration observed in every quarter period was found to decrease as follows: school>office>hospital>factory. The average effective dose to the public due to (222)Rn was estimated to be 0.41 mSv y(-1) weighted by the working population. Considering the (222)Rn exposure in indoor workplaces, effective dose to the general public is estimated to be in the range from approximately 0.42 to 0.52 mSv y(-1).  相似文献   

13.
Nationwide outdoor radon (222Rn) concentrations in Japan were measured to survey the environmental outdoor 222Rn level and to estimate the effective dose to the general public from 222Rn and its progeny. The 222Rn concentration was measured with a passive-type radon monitor. The 222Rn monitors were installed at about 700 points throughout Japan from 1997 to 1999. The annual mean 222Rn concentration in Japan was estimated from four quarters measurements of 47 prefectures in Japan. Nationwide outdoor mean 222Rn concentration was 6.1 Bq m(-3). This was about 40% of the indoor 222Rn concentration in Japan. The 222Rn concentration in Japan ranged from 3.3 Bq m(-3) in the Okinawa region to 9.8 Bq m(-3) in the Chugoku region, reflecting geological characteristics. Seasonal variation of outdoor 222Rn concentration was also found to be lowest in July to September, and highest in October to December. From the results of this 222Rn survey and previous indoor 222Rn survey program, the effective dose to the general public from 222Rn and its progeny was estimated to be 0.45 mSv y(-1).  相似文献   

14.
A radon survey has been carried out around the town of Niska Banja (Serbia) in a region partly located over travertine formations, showing an enhanced level of natural radioactivity. Outdoor and indoor radon concentrations were measured seasonally over the whole year, using CR-39 diffusion type radon detectors. Outdoor measurements were performed at 56 points distributed over both travertine and alluvium sediment formations. Indoor radon concentrations were measured in 102 living rooms and bedrooms of 65 family houses. In about 50% of all measurement sites, radon concentration was measured over each season separately, making it possible to estimate seasonal variations, which were then used to correct values measured over different periods, and to estimate annual values. The average annual indoor radon concentration was estimated at over 1500 Bq/m3 and at about 650 Bq/m3 in parts of Niska Banja located over travertine and alluvium sediment formations, respectively, with maximum values exceeding 6000 Bq/m3. The average value of outdoor annual radon concentration was 57 Bq/m3, with a maximum value of 168 Bq/m3. The high values of indoor and outdoor radon concentrations found at Niska Banja make this region a high natural background radiation area. Statistical analysis of our data confirms that the level of indoor radon concentration depends primarily on the underlying soil and building characteristics.  相似文献   

15.
A new winter and summer investigation of radon concentrations in parts of the Ogof Ffynnon Ddu system at Penwyllt, South Wales, has been carried out using 100 environmental National Radiological Protection Board track etch detectors. Fifty detectors were installed in the system in December 1998 and again in August 1999 for a period of a month. The data obtained confirm that the system has moderately high radon concentrations with a system mean of 2318 Bq m(-3) in winter and 2844 Bq m(-3) in summer. Traverse means have a summer high of 3094 Bq m(-3) for OFDI to Cwm Dwr and a winter low of 1946 Bq m(-3). The extremely high concentrations approaching 20,000 Bq m(-3), reported previously from the system (Hyland, 1995), have not been reproduced. The data show that the airflow directions at the entrances are not what might have been predicted. Air appears to be largely continuously emerging from the lowest entrance but, at the higher entrances, conversely to the predictions, in winter air enters and in summer appears to be coming out or is variable. Internally, there are sites that in winter have very low radon concentrations that can only be explained by the ingress of fresh air. These are not matched in the summer experiment, again indicating that ingress of fresh air to some parts of the system is very variable. The data illustrate the complexity of airflow within a multi-entrance system but behind these variations several mean concentrations can be obtained from which an approximation of the dose likely to be received can be calculated. Using the maximum mean concentration obtained, 3094 Bq m(-3), and using the latest dose conversion, a 10 h underground trip in the Ogof Ffynnon Ddu system yields a calculated dose of 0.12 mSv. Given that the recommended limit for a member of the public is 1 mSv, this dose would be reached after about 80 h of caving in the system.  相似文献   

16.
The paper presents the results of indoor radon concentration survey in 201 homes and offices in Niska Banja (the Spa of Nis), a well-known health resort and a spa in the South-East of Serbia. Radon indoor concentrations were determined by active charcoal method, according to standard EPA procedure. The indoor radon concentrations were in the range of up to 200 Bq/m(3) (47%), from 200-600 Bq/m(3) (26%) and over 600 Bq/m(3) (27%). Three areas of extremely high average radon concentrations were found (1,340-4,340 Bq/m(3)), with a maximum above 13,000 Bq/m(3). The content of natural radionuclides ((226)Ra, (214)Pb, (214)Bi, (235)U, (228)Ac, (212)Pb, (212)Bi, (208)Tl, (40)K) and (137)Cs, as well as the content of total uranium, thorium and potassium in mud used in peloidotherapy in the Health Institute "Niska Banja" was determined, too. The activities of the radionuclides were determined on an HPGe detector, by standard gamma spectroscopy. The results indicated considerably high amounts of total uranium and thorium (0.021 g/kg mud and 0.003 g/kg mud, respectively), due to the karsts origin of the soil.  相似文献   

17.
In the Harghita volcanic range (Romania) there are many occurrences of dry CO(2) emanations, called mofettes. The emanating gas with high carbon dioxide content has a proved curative effect. The gas also contains important quantities of radon. Since the mofettes are used in curative purposes in several illnesses, in most of the cases without medical supervising, has been proposed to determine the radon activity concentration in some of the most frequented mofettes from Romania. The seasonal variations have also been monitored and were calculated the effective doses received by the patients during a cure. The radon activity concentrations' levels above the mofettes indoor air range between 548 and 10 717Bq/m(3) while within the gas pools' values between 3210 and 32 781Bq/m(3) have been measured. The effective dose received by the patients during a cure is between 0.0086 and 0.16mSv. No major seasonal variations of the radon activity concentrations levels have been pointed out so far in the studied mofettes.  相似文献   

18.
Indoor radon survey and gamma activity measurements in soil samples were carried out in the Giresun province (Northeastern Turkey). The result of analysis of variance showed a relationship between indoor radon and radium content in soil (R(2)=0.54). It was found that indoor radon activity concentration ranged from 52 to 360 Bq m(-3) with an average value of 130 Bq m(-3). A model built by BEIR VI was used to predict the number of lung cancer deaths due to indoor radon exposure. It was found that indoor radon is responsible for 8% of all lung cancer deaths occurring in this province. (137)Cs activity concentration was measured 21 years after the Chernobyl accident. The results showed that (137)Cs activity concentration ranged from 41 to 1304 Bq kg(-1) with an average value of 307 Bq kg(-1). The indoor radon results and the geology of the studied area were discussed. Annual effective doses to the both radionuclides of natural origin and (137)Cs were estimated.  相似文献   

19.
The aim of this work was to make a comparison of indoor radon concentrations in dwellings and in soil air in the area of two geological formations in the Suwa?ki region (Poland). The mean arithmetic airborne concentration was found to be the highest (301 Bq m (-3)) in the basements of buildings in the gravel and sand areas, whereas in the boulder clay areas it reached 587 Bq m (-3). Out of 54 measurements of radon concentrations performed at the ground floor, in eight cases concentrations were found to exceed 200 Bq m (-3) - permissible radon level in new-built houses in Poland and in three cases these values were even higher than 400 Bq m (-3). The highest radon levels were noted in houses with earthen basement floors and with direct entrance from the basement to rooms or kitchens. The mean arithmetic radon concentration in the soil air in the sandy and gravel formations was 39.7 kBq m (-3) and in clay formation it was 26.5 kBq m (-3). Higher radon levels were also found in the water obtained from household wells reaching 8367 Bq m (-3) as compared with tap water (2690 Bqm (-3)). The mean indoor concentration for the whole area under study was found to be 169.4 Bq m (-3), which is higher than the mean value for Poland (49.1 Bq m (-3)) by a factor of 3.5.  相似文献   

20.
Radon concentrations in air and geothermal water of the spa pools in Croatia were measured and the average values of 40.3 and 4.5 kBq/m3 were obtained, respectively. Great difference between radon concentrations in pool and spring water was considered as a result of mixing normal and geothermal water in the pool as well as the radon decay. Estimation of an effective dose, received by the personnel in the Bizovac spa, gave the value of 0.27 mSv/y. At the location Stubica, the transfer factor of the radon for air and thermal water in the pool was calculated, and the value of 4.9+/-0.7 x 10(-3) was obtained.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号