首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 546 毫秒
1.
水质对紫外消毒在两种典型再生水中应用的影响   总被引:1,自引:0,他引:1  
以大肠杆菌为对象,研究了再生水水质变化对紫外消毒效果和光复活的影响。结果表明,紫外对大肠杆菌有很强的灭活作用,在紫外剂量为4mJ/cm^2时,大肠杆菌的灭活率达到了4.41个对数级。腐殖酸、铁和2种再生水水体中其他溶解性物质会影响光吸收和紫外透射率,但对紫外消毒动力学无影响。在颗粒物浓度为0~200mg/L的范围内,外源高岭土和活性污泥等颗粒物的投加对紫外消毒效果影响较小,而再生水水样W1中原有的2.61/1:g/L的颗粒物则会极大地影响消毒效果,使UV对细菌的灭活出现明显的拖尾现象。腐殖酸会增强紫外损伤大肠杆菌的光复活能力,但2种再生水中细菌的光复活能力相对磷酸盐缓冲溶液(PBS)中减弱,减弱程度在不同水样中有所不同。  相似文献   

2.
The treatment process described in this research explores the impact of exposing water samples containing fecal coliforms to the radiation produced by single ultraviolet (UV) light-emitting diodes (LEDs) operating at 265 nm. UV LEDs are long lasting, compact in size and produce more efficient light output than traditional mercury-vapour bulbs, making them ideal for application in point-of-use disinfection systems, such as in remote areas. In this study, contaminated water samples containing either a pure culture of Escherichia coli or tertiary effluent from the City of Regina Wastewater Treatment Plant were used to study the application and efficiency of using UV LEDs for water disinfection. The results indicate that bacterial inactivation was achieved in a time-dependent manner, with 1- and 2.5-log E. coli reductions in water following 20 and 50 min of UV LED exposure, respectively. Ultraviolet radiation was less effective in reducing coliform bacteria in wastewater samples due to the elevated turbidity levels. Further work remains to be completed to optimize the application of UV LEDs for point-of-use disinfection systems; however, the results from this study support that bacterial inactivation using UV LEDs is possible, meriting further future technological development of the LEDs.  相似文献   

3.
Dunlop PS  Ciavola M  Rizzo L  Byrne JA 《Chemosphere》2011,85(7):1160-1166
Solar disinfection (SODIS) of Escherichia coli suspensions in low-density polyethylene bag reactors was investigated as a low-cost disinfection method suitable for application in developing countries. The efficiency of a range of SODIS reactor configurations was examined (single skin (SS), double skin, black-backed single skin, silver-backed single skin (SBSS) and composite-backed single skin) using E. coli suspended in model and real surface water. Titanium dioxide was added to the reactors to improve the efficiency of the SODIS process. The effect of turbidity was also assessed. In addition to viable counts, E. coli injury was characterised through spread-plate analysis using selective and non-selective media. The optimal reactor configuration was determined to be the SBSS bag (t50 = 9.0 min) demonstrating the importance of UVA photons, as opposed to infrared in the SODIS disinfection mechanism. Complete inactivation (6.5-log) was achieved in the presence of turbidity (50 NTU) using the SBSS bag within 180 min simulated solar exposure. The addition of titanium dioxide (0.025 g L−1) significantly enhanced E. coli inactivation in the SS reactor, with 6-log inactivation observed within 90 min simulated solar exposure. During the early stages of both SODIS and photocatalytic disinfection, injured E. coli were detected; however, irreversible injury was caused and re-growth was not observed. Experiments under solar conditions were undertaken with total inactivation (6.5-log) observed in the SS reactor within 240 min, incomplete inactivation (4-log) was observed in SODIS bottles exposed to the same solar conditions.  相似文献   

4.
Sulfaquinoxaline (SQX) is an antimicrobial of the sulfonamide class, frequently detected at low levels in drinking and surface water as organic micropollutant. The main goal of the present study is the evaluation of SQX reactivity during chlorination and UV irradiations which are two processes mainly used in water treatment plants. The SQX transformation by chlorination and UV lights (254 nm) was investigated in purified water at common conditions used for water disinfection (pH =?7.2, temperature =?25 °C, [chlorine] =?3 mg L?1). The result shows a slow degradation of SQX during photolysis compared with chlorination process. Kinetic studies that fitted a fluence-based first-order kinetic model were used to determine the kinetic constants of SQX degradation; they were equal to 0.7?×?10?4 and 0.7?×?10?2 s?1corresponding to the half time lives of 162 and 1.64 min during photolysis and chlorination, respectively. In the second step, seven by-products were generated during a chlorination and photo-transformation of SQX and identified using liquid chromatography with electrospray ionization and tandem mass spectrometry (MS-MS). SO2 extrusion and direct decomposition were the common degradation pathway during photolysis and chlorination. Hydroxylation and isomerization were observed during photodegradation only while electrophilic substitution was observed during chlorination process.  相似文献   

5.
以枯草芽孢杆菌芽孢为模型微生物,研究了实际水体中单独氯消毒、单独臭氧消毒和臭氧-自由氯联合作用的灭菌效果.结果表明,枯草芽孢杆菌芽孢对单独氯消毒的抗性很大,6 mg/L氯作用240 min后灭活率仅为0.84个对数级;臭氧对枯草芽孢杆菌芽孢有较好的灭活效果,臭氧作用5 min,对其有4.68个对数级的灭活率.与单独氯消...  相似文献   

6.
研究水质对254 nm紫外线透射率的影响,通过动态实验考察了照射时间、254 nm紫外线透射率以及紫外线剂量对炼化企业中水消毒效果的影响并同时考察异养菌、硫酸盐还原菌和铁细菌的光复活及暗修复现象。结果表明,有机物是影响炼化企业中水紫外线消毒的重要因素;紫外线对炼化企业中水中的异养菌具有良好的灭活作用;增加照射时间对消毒效果的提升作用受254 nm紫外线透射率的影响;紫外线透射率在较低的范围内时对消毒效果的影响相对较大,在较高的范围内时影响较小;紫外线剂量-响应曲线受254 nm紫外线透射率的影响;剂量的“成分”,即照射时间和透射率的不同组合,也会对消毒效果产生影响;在80 mJ/cm2的剂量下,20 h内异养菌出现了较强烈的光复活和暗修复现象,铁细菌仅出现了明显的光复活现象,硫酸盐还原菌没有表现出明显的复活。  相似文献   

7.
Chlorination for drinking water forms various disinfection byproducts (DBPs) of trihalomethanes (THMs) and haloacetic acids (HAAs). Chlorination has been attributed to the destruction of activated aromatic sites of the natural organic matter (NOM) predominantly at electron rich sites. Experiments with Istanbul surface waters showed that the magnitude of the decrease in the ultraviolet (UV) absorbance at 272 nm (UV272) was an excellent indicator of destruction of these sites by chlorine. The main objective of the present study is to develop the differential UV272 absorbance (ΔUV272) related models for the prediction of the formation of THM, HAA, and their species in raw water samples from Terkos, Buyukcekmece, and Omerli lakes under different chlorination conditions. Significant factors affecting DBP formation in the raw waters were identified through numerical and graphical techniques. The R2 values of the models varied between 0.94 and 0.97, indicating excellent predictive ability for THM4 and HAA9 in the raw waters. The models were validated using additional data. The results of this study concluded that addition of ΔUV272 parameter into THM4 and HAA9 models make the prediction of these DBP compounds more precisely than those of DBP models developed in the past. A better understanding of these modeling systems will help the water treatment plant operators to minimize the DBP formation, providing a healthier and better drinking water quality as well as identifying strategies to improve water treatment and disinfection processes.  相似文献   

8.
Minimization of the formation of disinfection by-products   总被引:1,自引:0,他引:1  
The drinking water industry is required to minimize DBPs levels while ensuring adequate disinfection. In this study, efficient and appropriate treatment scheme for the reduction of disinfection by-product (DBPs) formation in drinking water containing natural organic matter has been established. This was carried out by the investigation of different treatment schemes consisting of enhanced coagulation, sedimentation, disinfection by using chlorine dioxide/ozone, filtration by sand filter, or granular activated carbon (GAC). Bench scale treatment schemes were applied on actual samples from different selected sites to identify the best conditions for the treatment of water. Samples were collected from effluent of each step in the treatment train in order to analyze pH, UV absorbance at 254 nm (UVA254), specific UV absorbance at 254 nm (SUVA254), dissolved organic carbon (DOC), haloacetic acids (HAAs) and trihalomethanes (THMs). The obtained results indicated that using pre-ozonation/enhanced coagulation/activated carbon filtration treatment train appears to be the most effective method for reducing DBPs precursors in drinking water treatment.  相似文献   

9.
The Ni-doped and N-doped TiO2 nanoparticles were investigated for their antibacterial activities on Staphylococcus aureus (S. aureus) and Escherichia coli (E. coli) bacteria. Their morphological features and characteristics such as particle size, surface area, and visible light absorbing capacity were compared and discussed. Scanning electron microscopy, X-ray diffraction, and UV–visible spectrophotometry were used to characterize both materials. The inactivation of E. coli (as an example of Gram-negative bacteria) and S. aureus (as an example of Gram-positive bacteria) with Ni-doped and N-doped TiO2 was investigated in the absence and presence of visible light. Antibacterial activity tests were conducted using undoped, Ni-doped, and N-doped TiO2. The N-doped TiO2 nanoparticles show higher antibacterial activity than Ni-doped TiO2. The band gap narrowing of N-doped TiO2 can induce more visible light absorption and leads to the superb antibacterial properties of this material. The complete inactivation time for E. coli at an initial cell concentration of 2.7?×?104 CFU/mL was 420 min which is longer than the 360 min required for S. aureus inactivation. The rate of inactivation of S. aureus using the doped TiO2 nanoparticles in the presence of visible light is greater than that of E. coli. The median lethal dose (LD50) values of S. aureus and E. coli by antibacterial activity under an 18-W visible light intensity were 80 and 350 mg/ml for N-doped TiO2, respectively.  相似文献   

10.
Jeong J  Kim JY  Cho M  Choi W  Yoon J 《Chemosphere》2007,67(4):652-659
Recently, the electrochemical disinfection has gained a great interest as one of the alternatives to conventional chlorination due to its high effectiveness and environmental compatibility. Despite the extensive reports on electro-chlorination disinfection, few researches were reported on the systems without generating chlorine. This study mainly focused on the potential disinfecting ability of electro-generated oxidants other than chlorine with using an inert medium (chloride-free phosphate buffer solution), which was intended to exclude the formation of chlorine during the electrolysis, as the Escherichia coli as an indicator bacterium was disinfected by applying the current to a platinum anode. The electrochemical inactivation of E. coli without chlorine production was demonstrated to occur in two distinct stages. The first stage inactivation takes place rapidly at the beginning of electrolysis, which appears to be achieved by the electrosorption of negatively charged E. coli cells to the anode surface, followed by a direct electron transfer reaction. As the electrolysis continues further, the inactivation becomes slower but steady, in contrast to the first stage of inactivation. This was attributed to the action of reactive oxidants generated from water discharge, such as hydroxyl radical. Overall, this study suggests that the electrochemical disinfection could be successfully performed even without producing chlorine, recommending the potential application for disinfecting water that does not allow including any chloride ions (such as the production of ultra-pure sterilized water for semiconductor washing).  相似文献   

11.
为研究中水消毒过程,对次氯酸钠消毒中水的折点加氯反应与消毒效果之间的关系进行研究。通过探讨加氯量位于折点曲线不同位置的消毒效果,分析接触时间和氨氮浓度的影响,得出了根据氨氮浓度确定的接触时间和加氯量公式。结果表明,氨氮浓度〈2 mg/L时,将加氯量控制在折点之后接触反应30 min,氨氮浓度〉2 mg/L时,将加氯量控制在峰点附近接触反应60 min均可实现中水消毒要求。  相似文献   

12.

Purpose

The disinfection efficiency of water and secondary treated wastewater by means of photoelectrocatalytic oxidation (PEC) using reference strains of Enterococcus faecalis and Escherichia coli as faecal indicators was evaluated. Operating parameters such as applied potential (2?C10?V), initial bacterial concentration (103?C107?CFU/mL), treatment time (up to 90?min) and aqueous matrix (pure water and treated effluent) were assessed concerning their impact on disinfection.

Methods

PEC experiments were carried out using a TiO2/Ti film anode and a zirconium cathode in the presence of simulated solar radiation. Bacterial inactivation was monitored by the culture method and real-time SYBR green PCR.

Results

A 6.2 log reduction in E. faecalis population was achieved after 15?min of PEC treatment in water at 10?V of applied potential and an initial concentration of 107?CFU/mL; pure photocatalysis (PC) led to only about 4.3 log reduction, whilst negligible inactivation was recorded when the respective electrochemical oxidation process was applied (i.e. without radiation). PEC efficiency was generally improved increasing the applied potential and decreasing initial bacterial concentration. Regarding real wastewater, E. coli was more susceptible than E. faecalis during treatment at a potential of 5?V. Wastewater disinfection was affected by its complex composition and the contained mixed bacterial populations, yielding lower inactivation rates compared to water treatment. Screening the results obtained from both applied techniques (culture method and real-time PCR), there was a discrepancy regarding the recorded time periods of total bacterial inactivation, with qPCR revealing longer periods for complete bacterial reduction.

Conclusions

PEC is superior to PC in terms of E. faecalis inactivation presumably due to a more efficient separation and utilization of the photogenerated charge carriers, and it is mainly affected by the applied potential, initial bacterial concentration and the aqueous matrix.  相似文献   

13.
Drinking water in the vast Arctic Canadian territory of Nunavut is sourced from surface water lakes or rivers and transferred to man-made or natural reservoirs. The raw water is at a minimum treated by chlorination and distributed to customers either by trucks delivering to a water storage tank inside buildings or through a piped distribution system. The objective of this study was to characterize the chemical and microbial drinking water quality from source to tap in three hamlets (Coral Harbour, Pond Inlet and Pangnirtung—each has a population of <2000) on trucked service, and in Iqaluit (population ~6700), which uses a combination of trucked and piped water conveyance. Generally, the source and drinking water was of satisfactory microbial quality, containing Escherichia coli levels of <1 MPN/100 mL with a few exceptions, and selected pathogenic bacteria and parasites were below detection limits using quantitative polymerase chain reaction (qPCR) methods. Tap water in households receiving trucked water contained less than the recommended 0.2 mg/L of free chlorine, while piped drinking water in Iqaluit complied with Health Canada guidelines for residual chlorine (i.e. >0.2 mg/L free chlorine). Some buildings in the four communities contained manganese (Mn), copper (Cu), iron (Fe) and/or lead (Pb) concentrations above Health Canada guideline values for the aesthetic (Mn, Cu and Fe) and health (Pb) objectives. Corrosion of components of the drinking water distribution system (household storage tanks, premise plumbing) could be contributing to Pb, Cu and Fe levels, as the source water in three of the four communities had low alkalinity. The results point to the need for robust disinfection, which may include secondary disinfection or point-of-use disinfection, to prevent microbial risks in drinking water tanks in buildings and ultimately at the tap.  相似文献   

14.
Escherichia coli (E. coli) and Bacillus megaterium bacteria were frozen at -15 degrees C using a freezer and a spray freezing method. The frozen Bacillus spores were also exposed to UV and free chlorine. An average of 4.7-log inactivation was obtained from the spray ice with 2-day storage time, while the freezer freezing only caused 0.84-log reduction with the same storage time. Significantly higher inactivation levels were observed for the E. coli cells with 2-day storage compared with those without storage. The spray freezing was found more effective in killing the E. coli cells, while more cells were sublethally injured by the freezer freezing. Freezing did not kill the Bacillus megaterium spores, but affected their response to UV and chlorine. Greater inactivation levels were observed at higher free chlorine doses or longer contact time, and the UV fluence-response curve showed initial rapid kill followed by tailing for the frozen spores.  相似文献   

15.

Purpose  

The present research aims to investigate the individual and interactive effects of chlorine dose/dissolved organic carbon ratio, pH, temperature, bromide concentration, and reaction time on trihalomethanes (THMs) formation in surface water (a drinking water source) during disinfection by chlorination in a prototype laboratory-scale simulation and to develop a model for the prediction and optimization of THMs levels in chlorinated water for their effective control.  相似文献   

16.
鼠伤寒沙门氏菌的紫外灭活及光复活抑制的研究   总被引:1,自引:0,他引:1  
研究了鼠伤寒沙门氏菌的紫外失活动力学、在日光灯下的光复活现象以及氯对其光复活的抑制。结果表明,鼠伤寒沙门氏菌的紫外失活动力学曲线分为滞后区、一级动力学区、拖尾区三阶段,在PBS中的一级动力学失活速率常数为0.9041 cm2/mJ。而紫外灭活后的鼠伤寒沙门氏菌在日光灯下存在光复活。当紫外剂量为10 mJ/cm2时,鼠伤寒沙门氏菌在日光灯下照射3 h内发生明显的光复活,浓度从8.6×103CFU/mL增加到4.1×106 CFU/mL;但是在紫外消毒后,投加1 mg/L的氯可以有效抑制该细菌的光复活,投加2 mg/L的氯可以在10 min内全部灭活。因此,紫外-氯联合消毒能够有效的抑制鼠伤寒沙门氏菌细菌光复活,使其得到高效灭活。  相似文献   

17.

Purpose  

Need, coupled with advances in water treatment technology, is motivating a growing interest in augmenting drinking water supplies with reclaimed water. Using reclaimed water to increase the flow of the Llobregat River upstream the water catchment site of the complex multi-step drinking water treatment plant of Sant Joan Despí has been considered. The impact of reclaimed water discharges on the load of E. coli, spores of sulphite-reducing clostridia, somatic coliphages, cytopathogenic enteroviruses, and total and infectious Cryptosporidium oocysts in the Llobregat River water was assessed to gain information for funded decisions in potential future emergencies.  相似文献   

18.
Nano-silver is increasingly used in consumer products from washing machines and refrigerators to devices marketed for the disinfection of drinking water or recreational water. The nano-silver in these products may be released, ending up in surface water bodies which may be used as drinking water sources. Little information is available about the stability of the nano-silver in sources of drinking water, its fate during drinking water disinfection processes, and its interaction with disinfection agents and disinfection by-products (DBPs). This study aims to investigate the stability of nano-silver in drinking water sources and in the finished drinking water when chlorine and chloramines are used for disinfection and to observe changes in the composition of DBPs formed when nano-silver is present in the source water. A dispersion of nano-silver particles (10 nm; PVP-coated) was used to spike untreated Ottawa River water, treated Ottawa River water, organic-free water, and a groundwater at concentrations of 5 mg/L. The diluted dispersions were kept under stirred and non-stirred conditions for up to 9 months and analyzed weekly using UV absorption to assess the stability of the nano-silver particles. In a separate experiment, Ottawa River water containing nano-silver particles (at 0.1 and 1 mg/L concentration, respectively) was disinfected by adding sodium hypochlorite (a chlorinating agent) in sufficient amounts to maintain a free chlorine residual of approximately 0.4 mg/L after 24 h. The disinfected drinking water was then quenched with ascorbic acid and analyzed for 34 neutral DBPs (trihalomethanes, haloacetonitriles, haloacetaldehydes, 1,1 dichloro-2-propanone, 1,1,1 trichloro-2-propanone, chloropicrin, and cyanogen chloride). The results were compared to the profile of DBPs obtained under the same conditions in the absence of nano-silver and in the presence of an equivalent concentration of Ag+ ions (as AgNO3). The stability of the nano-silver dispersions in untreated Ottawa River water, with a dissolved organic carbon concentration of 6 mg/L, was significantly higher than the stability of the nano-silver dispersions in distilled, organic-free water. Nano-silver particles suspended in the groundwater agglomerated and were quickly and quantitatively removed from the solution. Our data confirm previous observations that natural dissolved organic matter stabilizes nano-silver particles, while the high-ionic strength of groundwater appears to favor their agglomeration and precipitation. As expected, nano-silver was not stable in Ottawa River water through the chlorination process, but survived for many days when added to the Ottawa River water after treatment with chlorine or chloramines. Stirring appeared to have minimal effect on nano-silver stability in untreated and treated Ottawa River water. The profile of DBPs formed in the presence of nAg differed significantly from the profile of DBPs formed in the absence of nAg only at the 1 mg/L nAg concentration. The differences observed consisted mainly in reduced formation of some brominated DBPs and a small increase in the formation of cyanogen chloride. The reduced formation of brominated congeners may be explained by the decrease in available bromide due to the presence of Ag+ ions. It should be noted that a concentration of 1 mg/L is significantly higher than nAg concentrations that would be expected to be present in surface waters, but these results could be significant for the disinfection of some wastewaters with comparably high nano-silver concentrations.  相似文献   

19.
Faecal indicator bacteria (FIB) are commonly used as water quality indicators; implying faecal contamination and therefore the potential presence of pathogenic enteric bacteria, viruses, and protozoa. Hence in wastewater treatment, the most commonly used treatment process measures (surrogates) are total coliforms, faecal coliforms, Escherichia coli (E. coli), and enterococci. However, greywater potentially contains skin pathogens unrelated to faecal load, and E. coli and other FIB may grow within greywater unrelated to pathogens. Overall, FIB occurs at fluctuating and relatively low concentrations compared to other endogenous greywater bacteria affecting their ability as surrogates for pathogen reduction. Therefore, unlike municipal sewage, FIB provides a very limited and unreliable log-reduction surrogate measure for on-site greywater treatment systems. Based on our recent metagenomic study of laundry greywater, skin-associated bacteria such as Staphylococcus, Corynebacterium, and Propionibacterium spp. dominate and may result in more consistent treatment surrogates than traditional FIB. Here, we investigated various Staphylococcus spp. as potential surrogates to reliably assay over 4-log10 reduction by the final-stage UV disinfection step commonly used for on-site greywater reuse, and compare them to various FIB/phage surrogates. A collimated UV beam was used to determine the efficacy of UV inactivation (255, 265 and 285 nm) against E. coli, Enterococcus faecalis, E. faecium, E. casseliflavus, Staphylococcus aureus, and S. epidermidis. Staphylococcus spp. was estimated by combining the bi-linear dose-response curves for S. aureus and S. epidermidis and was shown to be less resistant to UV irradiation than the other surrogates examined. Hence, a relative inactivation credit is suggested; whereas, the doses required to achieve a 4 and 5-log10 reduction of Staphylococcus spp. (13.0 and 20.9 mJ cm?2, respectively) were used to determine the relative inactivation of the other microorganisms investigated. The doses required to achieve a 4 and 5-log10 reduction of Staphylococcus spp. resulted in a log10 reduction of 1.4 and 4.1 for E. coli, 0.8 and 2.8 for E. faecalis, 0.8 and 3.6 for E. casseliflavus and 0.8 and 1.2 for MS2 coliphage, respectively. Given the concentration difference of Staphylococcus spp. and FIB (3 to 5-log10 higher), we propose the use of Staphylococcus spp. as a novel endogenous performance surrogate to demonstrate greywater treatment performance given its relatively high and consistent concentration and therefore ability to demonstrate over 5-log10 reductions.  相似文献   

20.
Buth JM  Ross MR  McNeill K  Arnold WA 《Chemosphere》2011,84(9):1238-1243
Triclosan, a common antimicrobial agent, may react during the disinfection of wastewater with free chlorine to form three chlorinated triclosan derivatives (CTDs). This is of concern because the CTDs may be photochemically transformed to tri- and tetra-chlorinated dibenzo-p-dioxins when discharged into natural waters. In this study, wastewater influent, secondary (pre-disinfection) effluent, and final (post-disinfection) effluent samples were collected on two occasions each from two activated sludge wastewater treatment plants, one using chlorine disinfection and one using UV disinfection. Concentrations of triclosan and three CTDs were determined using ultra performance liquid chromatography-triple quadrupole mass spectrometry with isotope dilution methodology. Triclosan and the CTDs were detected in every influent sample at levels ranging from 453 to 4530 and 2 to 98 ng L−1, respectively, though both were efficiently removed from the liquid phase during activated sludge treatment. Triclosan concentrations in the pre-disinfection effluent ranged from 36 to 212 ng L−1, while CTD concentrations were below the limit of quantification (1 ng L−1) for most samples. In the treatment plant that used chlorine disinfection, triclosan concentrations decreased while CTDs were formed during chlorination, as evidenced by CTD levels as high as 22 ng L−1 in the final effluent. No CTDs were detected in the final effluent of the treatment plant that used UV disinfection. The total CTD concentration in the final effluent of the chlorinating treatment plant reached nearly one third of the triclosan concentration, demonstrating that the chlorine disinfection step played a substantial role in the fate of triclosan in this system.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏