首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
It appears from current evidence that the most effective screening strategy for Down syndrome will involve a combination of first trimester nuchal translucency and serum biochemistry, whether performed in the first or second trimester. The aim of this study was to determine the optimum gestation based upon menstrual dates at which to schedule nuchal translucency (NT) measurement for the evaluation of fetal Down syndrome risk. Five thousand eight hundred and thirty-five pregnancies had an ultrasound scan scheduled between 11 and 14 completed weeks of gestation based upon either the last menstrual period (n = 3199) or a prior ultrasound scan (n = 2636). For last menstrual period-based ultrasound scans, with advancing gestation the frequency of missed miscarriage significantly decreased (p = 0.009, chi squared test), as did the need to reschedule a further scan because the gestation of the scheduled scan was too early to measure NT (p < 0.0001, Chi-squared test). In contrast, with advancing gestation the rate of unsuccessful NT measurement because the crown–rump length (CRL) was greater than 84 mm significantly increased (p < 0.0001, Chi-squared test). Of the women who had had an earlier ultrasound, 42 (1.6%) had a missed miscarriage and 9 (0.3%) were over gestation at the time of the NT scan. These data suggest that when only the last menstrual period is known the optimum time to schedule a nuchal translucency measurement is at 12 to 13 weeks' gestation. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

2.
Recent data have suggested that fetal nuchal translucency (NT) is affected by fetal gender. We investigated the size of this effect in 12 189 unselected pregnancies with known normal outcomes that had undergone NT measurements between 10 and 14 weeks of gestation. NT increased with gestation and was converted to multiples of the median (MoM) for the gestational day. The median NT MoM (95% CI) for female fetuses was 0.98 (0.97–0.99). This was significantly lower than that of the male fetuses (1.03; range1.02–1.04) (p<0.0005; Wilcoxon rank-sum test). The gender difference was not observed at 10 weeks but was observed from 11 weeks onwards. There is no obvious explanation for the above findings. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

3.
Objective The aim of this study is to describe a fetus with androgen insensitivity syndrome diagnosed at mid-second trimester. Case and Methods Nuchal translucency was measured thick and double test was found higher. The patient referred to our center at 16th weeks of gestation. Fetal ultrasound examination and amniocentesis was performed. Results The nuchal translucency (NT) of fetus in present pregnancy was measured approximately 10 mm at 13 weeks and Down syndrome risk was calculated 1 in 10 by double test. On ultrasound examination; thick nuchal fold (NF) and short fetal limbs were found, and the fetus was seen a female and amniocentesis was performed. Three weeks later the fetal karyotype was reported normal as 46,XY. Thereupon the fetus reexamined for 2D and 4D ultrasound, and confirmed previous findings. The fetus was terminated at 19th weeks and seen a female phenotype. The fetal gonads removed in abdomen and testicles confirmed histopatologically. Conclusion In generally, diagnosis of AIS is most made postnatally. This is the second case in English literature, which diagnosed mid-second trimester. In this situation, the fetus with thick NT/NF and short limbs may be AIS, therefore appearance of fetal sex on ultrasound should be compared with genetic sex Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

4.
The aim of the present study was to assess the sonographic contour of the increased nuchal translucency (NT) and to correlate this with pregnancy outcome. Fifty sonographic images of fetuses with increased NT [>95th centile thickness of the normal range for crown–rump length (CRL) between 38 and 84 mm] were retrospectively assessed. In all the cases a complete pregnancy and even infancy follow-up (<36 months) was available. The NT appearances were subdivided into two forms: a ‘notched’ or ‘uniform’ appearance. The images were correlated with karyotype results [trisomy 21 (DS) vs euploid cases] and pregnancy outcome. Complicated outcomes were classified as being either DS fetuses, miscarriage or termination of pregnancy because of structural anomaly. Thus 30/35 (86%) of the euploid fetuses had a ‘uniformly’ increased NT, whereas 8/13 DS cases (62%) had a ‘notched’ appearance (Fisher's exact test, p=0.004). Additionally, 27/29 fetuses (93%) which had an uneventful pregnancy outcome had a ‘uniform’ increased NT, whereas 12/26 (57%) of the fetuses which had adverse pregnancy outcome had a ‘notched’ appearance of their NT (Fisher's exact test, p<0.001). Although it was not possible to correlate the sonographic data with post-evacuation microdissection findings, it is possible that a uniformly shaped, increased NT may be more representative of a developmental delay in a normal fetus. Conversely, a ‘notched’ nuchal surface may represent abnormal lymphatic or cardiovascular development more commonly seen in DS fetuses. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

5.
Increased fetal nuchal translucency (NT) in the first trimester is associated with adverse pregnancy outcomes. Whether the increased NT is also associated with an increased frequency of pregnancy-associated hypertension (PAH) is not known. Seven hundred and seventy-nine pregnant women who received NT-based Down syndrome screening and delivered their babies at our hospital by September 2000 were enrolled into this study. Among these women, there are 46 cases of preeclampsia, 68 cases of gestational hypertension (GH); 665 women without any adverse pregnancy outcomes served as controls. Correlation analysis demonstrated that NT MoM (multiples of median) level had a positive association with maternal diastolic blood pressure at the time of admission for delivery (r = 0.104; p < 0.01). The severity of PAH was concordant with the stepwise increase of mean NT MoM level, which was 0.88 in control, 1.07 in gestational hypertension, and 1.13 in preeclampsia (p < 0.001). Using the 95th (1.52 MoM) and 90th (1.31 MoM) percentiles of NT thickness as cut-offs, the sensitivities and odds ratios of the women at risk for developing GH after 20 weeks of gestation were 8.8%, 19.1% and 1.98, 2.15 respectively, while for preeclampsia were 10.9%, 28.3% and 2.49, 3.58 respectively. It is concluded that the pathological changes in the placenta responsible for the development of PAH may also influence the physiological decrease of NT thickness in late first trimester. However, the sensitivity of fetal NT measurement in first trimester is not sufficient as a single marker for predicting the pregnant women at risk for subsequent PAH. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

6.
Objective To investigate the involvement of the genes encoding for COL6A1, COLA2 and super-oxide dismutase (SOD) in the mechanism for the retention of subcutaneous fluid in fetuses with trisomy 21. Methods During a 7-month period (November 2004–May 2005), human fetal skin from the nuchal region was obtained from euploid fetuses and from fetuses with trisomy 21 following abortions and terminations of pregnancy. Cell cultures were performed from nuchal skin. Quantification of COL6A1, COL6A2, COL6A3 and SOD mRNAs were performed using real-time quantitative RT-PCR. Results Twelve fetuses were studied between 13–15 and 19–20 weeks of gestation including 7 cases of trisomy 21. A significant overexpression of genes of interest was demonstrated in trisomy 21 fetuses when compared with euploid fetuses, in the first and in the second trimester of pregnancy (p < 0.0001). Conclusion This study demonstrates a homogeneous overexpression of the genes encoding for α1 and α2 chains of Collagen type VI, and SOD in nuchal skin of human trisomy 21 fetuses. Persistence of this overexpression in the second trimester of pregnancy, despite the absence of an enlarged nuchal translucency (NT), may characterize some compensatory mechanisms. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

7.
Prevalence of congenital heart disease increases with nuchal translucency (NT) thickness. First-trimester fetal bradycardia may result from heart block associated with complex congenital heart disease. We report two cases detected in the first trimester of pregnancy, in which both fetuses showed an increased nuchal translucency and bradycardia. Fetal karyotype was normal in both fetuses. First-trimester fetal echocardiography was performed and, in both cases, complex congenital heart disease was diagnosed. We discuss the added role of fetal heart rate in first-trimester ultrasound screening, in fetuses with increased nuchal translucency and normal karyotype. We stress, as well, the importance of echocardiography performed in the first trimester as a potential tool for early diagnosis in selected cases. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

8.
In pregnancies obtained after assisted reproduction the false-positive rate of second trimester Down syndrome (DS) screening is increased by 1.5–3-fold. This may cause an increase in the number of amniocenteses and the fetal loss rate. The present study for the first time examined whether assisted reproductive technologies affect the results of first trimester screening. The markers PAPP-A, free β-hCG and the nuchal translucency (NT) thickness were examined at 12–14 weeks' gestation. Screening markers in 47 in vitro fertilisation (IVF), 63 ovulation induction (OI) and 3026 spontaneously conceived singleton pregnancies were compared. The MoM (multiples of the median) value in the IVF pregnancies was 1.02 (95% CI: 0.85–1.22) for PAPP-A, 1.14 (95% CI: 0.95–1.37) for β-hCG and 0.97 (95% CI: 0.89–1.05) for NT; the MoM value in the OI pregnancies was 0.89 (95% CI: 0.76–1.05) for PAPP-A, 1.08 (95% CI: 0.93–1.25) for β-hCG and 1.02 (95% CI: 0.95–1.11) for NT. The first trimester marker values in assisted reproductive pregnancies and spontaneously conceived pregnancies were not significantly different. Estimated false-positive rates for a risk cut-off of 1:400 varied from 4.7% in IVF pregnancies to 5.1% in OI pregnancies. Therefore the false-positive rate in Down syndrome screening should be independent of the method of conception. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

9.
Fetal nuchal translucency was measured at 11–14 weeks' gestation in 97 pregnancies referred for early amniocentesis for advanced maternal age. The nuchal translucency was abnormal in 11 fetuses and the fetal karyotype was abnormal in five of these 11 cases. The karyotype was normal in 86 cases with normal nuchal translucency. The culture failure and miscarriage rates associated with early amniocentesis were 3·3 per cent and 2·2 per cent respectively. Amniotic fluid leakage occurred in 6 per cent of cases. In women requesting fetal karyotyping for advanced maternal age without additional biochemical screening, fetal nuchal translucency should be measured at 11–14 weeks. If the nuchal thickness is ≥ 3 mm, a first-trimester diagnostic procedure is indicated; however, if it is <3 mm, amniocentesis should be delayed until 16 weeks' gestation.  相似文献   

10.
In a group of 149 women who had undergone routine first trimester screening using fetal nuchal translucency thickness (NT) and maternal serum free β-hCG and pregnancy associated plasma protein-A (PAPP-A) in two consecutive pregnancies the within person between pregnancy biological variability of these markers has been assessed. For fetal NT there was no correlation between NT MoM in the first and second pregnancy (r=0.0800). For maternal serum free β-hCG MoM a significant correlation was observed (r=0.4174) as was also found for PAPP-A MoM (r=0.3270). The implications for such between pregnancy marker association is that women who have an increased risk of Down syndrome in their first pregnancy are 1.5–2 times more likely to repeat this event in their next pregnancy. This observation may be useful in counselling women in the first trimester screening of a subsequent pregnancy. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

11.
A method is described to combine the ultrasound marker nuchal translucency (NT) with serum markers so that they can be used together in prenatal screening for Down syndrome in twin pregnancies. For monochorionic twin pregnancies (taken as monozygous), the two fetus-specific NT measurements are averaged before risk is calculated and before the contribution of the serum markers is incorporated. For dichorionic twin pregnancies (taken as dizygous), the risk for each fetus based on the individual NT measurements is calculated, the two fetus-specific risks are added together, and then the contribution of the serum markers is incorporated. In this way, all the screening markers can be used in combination to produce a pregnancy-specific ‘pseudo-risk’, rather than a fetus-specific pseudo-risk. We refer to pseudo-risk because in the absence of sufficient data on the screening markers in affected twin pregnancies, a true risk estimate cannot be calculated. Tentative estimates are given of screening performance in twins using NT, the combined test (NT with first-trimester serum markers), and the integrated test (NT with first- and second-trimester serum markers), all interpreted with maternal age. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

12.
We report a de novo translocation between chromosome 15 and 18 resulting in monosomy 18p in prenatal diagnosis. The patient was referred for amniocentesis due to increased nuchal translucency (INT) (5 mm) at 13.6 weeks of gestation. Karyotype of the fetus revealed 45,XX,der(15;18)(q10;q10) in all metaphases. The targeted fetal ultrasound at 20 weeks of gestation did not show any special physical abnormalities other than 6.4 mm of nuchal fold thickness. Molecular cytogenetic findings using CGH and FISH confirmed the del(18p) with dicentromeres from both chromosome 15 and 18. The present study shows that the INT at first trimester was the only prenatal finding for the fetus with del(18p) syndrome and that molecular cytogenetic methods are useful for detecting chromosomal aberrations precisely. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

13.

Objectives

To give an overview of the genetic and structural abnormalities occurring in fetuses with nuchal translucency (NT) measurement exceeding the 95th percentile at first-trimester screening and to investigate which of these abnormalities would be missed if cell-free fetal DNA (cfDNA) were used as a first-tier screening test for chromosomal abnormalities.

Methods

This is a national study including 1901 pregnancies with NT≥95th percentile referred to seven university hospitals in the Netherlands between 1 January 2010 and 1 January 2016. All cases with unknown pregnancy outcome were excluded. Results of detailed ultrasound examinations, karyotyping, genotyping, pregnancy and neonatal outcomes, investigation by a clinical geneticist and post-mortem investigations were collected.

Results

In total, 821 (43%) pregnancies had at least one abnormality. The rate of abnormalities was 21% for fetuses with NT between 95th and 99th percentile and 62% for fetuses with NT≥99th percentile. Prevalence of single-gene disorders, submicroscopic, chromosomal and structural abnormalities was 2%, 2%, 30% and 9%, respectively.

Conclusion

Although cfDNA is superior to the combined test, especially for the detection of trisomy 21, 34% of the congenital abnormalities occurring in fetuses with increased NT may remain undetected in the first trimester of pregnancy, unless cfDNA is used in combination with fetal sonographic assessment, including NT measurement.  相似文献   

14.
In a study of 180 twin pregnancies I have examined the distribution of maternal serum free β-human chorionic gonadotrophin (β-hCG) and pregnancy-associated plasma protein-A (PAPP-A), in addition to fetal nuchal translucency thickness (NT), in twins classified as monochorionic or dichorionic, based on ultrasound appearance at 10–14 weeks of gestation. In 45 monochorionic and 135 dichorionic twin pregnancies the median MoM free β-hCG was not significantly different (1.00 vs 1.01), whilst that for PAPP-A was lower (0.89 vs 1.01) but again with no statistical significance. Previous reports of an increased fetal NT in monochorionic twins pregnancies could not be confirmed (1.03 vs 1.00). It is concluded that the existing pseudo risk twin correction algorithm is appropriate for both monochorionic and dichorionic twins in providing accurate first trimester risks for trisomy 21. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

15.
We report on a fetus presenting with increased nuchal translucency at 11 weeks' gestation, suggesting cystic hygroma. Chorion villous sampling was performed, and cytogenetic analysis revealed a supernumerary isochromosome 5p leading to tetrasomy 5p: 47,XX,+ i(5p)[7]/46,XX[5] after short-term culture and 47,XX,+ i(5p)[20] after long-term culture. Subsequent targeted sonographic follow-up at 12 and 14 weeks revealed further increase of the NT to 6.4 mm and the additional presence of a congenital heart defect (pulmonary atresia with intact ventricular septum). Termination of pregnancy was performed, and the heart defect was confirmed. Isochromosome 5p was found in varying proportions in all examined organs. Only a few cases of mosaic tetrasomy 5p have been reported in the literature, and recent reports on prenatally detected isochromosome 5p showed a possible relationship to increased nuchal translucency in some cases and also a possible role of confined mosaicism in others. Whereas cases with confined mosaicism did not show suspicious signs on ultrasound, true mosaicism conversely showed increased nuchal thickness as well as structural abnormalities. This is the first report on the association of a cardiac defect with this chromosome aberration. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

16.
This is the first report of a fetus affected with campomelic acampomelic dysplasia presenting with increased nuchal translucency. Ultrasonography at 13 weeks of amenorrhea showed a nuchal translucency 5.6 mm thick. The karyotype performed on amniotic fluid cells was normal (46,XY). Ultrasonography at 22 weeks revealed a normal femoral length and female genitalia. A second amniocentesis was performed to confirm the karyotype and for dosage of steroid hormones. Testosterone dosage was low, corresponding to a female fetus. Ultrasonography at 32 weeks showed growth retardation of the long bones (<3rd centile) that were not curved. A severe malformation syndrome was suspected and the pregnancy was terminated at 33 weeks. The fetus displayed macrocephaly, facial dysmorphism and female external genitalia. X ray showed straight and thickened long bones, hypoplastic scapulae and moderate platyspondyly. In view of the association of sex reversal, hypoplasia of the scapulae, and the presence of straight long bones, campomelic acampomelic dysplasia was suspected and confirmed by the finding of a SOX9 mutation. This case shows the importance of a careful echographic survey in a fetus with a nuchal translucency > 4 mm, especially if there is discordance between phenotypic and genotypic sex, since growth retardation may occur later during the pregnancy. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

17.
We assessed the discriminatory efficiency and cost-effectiveness of a novel way of organising first trimester screening for Down syndrome (DS), contingent testing, where a serological test (PAPP-A and β-hCG: the double test) is made in early first trimester and followed by nuchal translucency testing (NT) only in women with an intermediate risk, e.g. <1:65 and >1:1000, and not in all women as in normal first trimester screening (NFTS). Using Monte Carlo simulation contingent testing had a detection rate (DR) of 78.9% and a false-positive rate (FPR) of 4.0% for DS with 19.4% of women offered NT testing. The DR of NFTS was 85.5% and the FPR 4.4%. The decrease in NT screening was associated with an increase from 23% to 29% in the proportion of DS cases born. The cost of the contingent testing programme was £53 000 per DS case not born and £91 000 in NFTS. The number of aborted fetuses per DS case were 0.35 and 0.36, respectively. Thus, contingent testing is an organisation of first trimester screening where costs can be reduced with a marginal decrease in performance. Contingent testing is attractive in areas where NT screening is the bottleneck preventing the introduction of first trimester screening. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

18.
19.
We report on the prenatal diagnosis of ring chromosome 15 in a fetus with increased nuchal fold and intrauterine growth restriction (IUGR). A 27-year-old woman gravida 2, para 1 had normal maternal serum screen tests in the early second trimester of the index pregnancy. Fetal nuchal fold thickening up to 8 mm was incidentally found during the routine obstetric ultrasound scan at 20 weeks' gestation. Amniocentesis was undertaken and the fetal karyotype was found to be 46,XY,r(15) on cytogenetic study. Fluorescence in situ hybridization (FISH) using a telomeric probe of chromosome 15 demonstrated a terminal deletion on the q arm of the ring-shaped chromosome 15. This is the first report of a prenatally diagnosed case of ring chromosome 15. Moreover, nuchal fold thickness in the second trimester may have a role in its prenatal diagnosis. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

20.
In this overview the current knowledge of the relationship between an increased nuchal translucency (NT) measurement and fetal heart structure and function in chromosomally normal fetuses is reviewed. Relevant pathophysiological theories behind the increased NT are discussed. Fetuses with an increased NT have an increased risk for congenital heart disease (CHD) with no particular bias for one form of CHD over another. This risk increases with increasing NT measurement. Although the NT measurement is only a modestly effective screening tool for all CHD when used alone, it may indeed be effective in identifying specific CHD “likely to benefit” from prenatal diagnosis. The combination of an increased NT, tricuspid regurgitation and an abnormal ductus venosus (DV) Doppler flow profile, is a strong marker for CHD. A fetal echocardiogram should be performed at 20 weeks' gestation in fetuses with an NT ≥ 95th percentile but < 99th percentile. When the NT measurement is ≥ 99th percentile, or when tricuspid regurgitation and/or an abnormal DV flow pattern is found along with the increased NT, an earlier echocardiogram is indicated, followed by a repeat scan at around 20 weeks' gestation. The resultant increased demand for early fetal echocardiography and sonographers with this special expertise needs to be planned and provided for. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号