首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 324 毫秒
1.
Dimeric inhibin A was measured in maternal serum samples from 45 pregnancies affected by trisomy 21 and 493 samples from unaffected pregnancies at 10–14 weeks of gestation. Inhibin A levels in affected pregnancies were compared with levels of free β-hCG and PAPP-A in the same series. In the trisomy 21 group, the median multiple of the median (MoM) inhibin A was not significantly elevated (1.28 vs 1.00) with only 15.5% being above the 95th centile. In contrast, the median MoM free β-hCG was significantly increased (2.05 vs 1.00) with 36% above the 95th centile and PAPP-A was significantly reduced (0.49 vs 1.00) with 42% below the 5th centile. Inhibin A levels in the trisomy 21 group were significantly correlated with gestational age such that median levels rose from 1.04 at 11 weeks to 1.30 at 12 weeks and 1.67 at 13 weeks. These findings suggest that first trimester biochemical screening for trisomy 21, which is currently optimised using maternal serum free β-hCG and PAPP-A and fetal nuchal translucency, will not benefit from the inclusion of inhibin A. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

2.
In 45 cases of trisomy 18 and 493 control pregnancies at 10–14 weeks of gestation, maternal serum inhibin A, total activin A, free β-hCG and PAPP-A were measured. In the trisomy 18 pregnancies the median values were 0.74 MoM for inhibin A, 1.23 MoM for activin A, 0.38 MoM for free β-hCG and 0.16 MoM for PAPP-A. The degree of deviation from normal in the levels of inhibin and activin is small in comparison with free β-hCG and PAPP-A and they are therefore unlikely to be of value in improving the sensitivity of 90% for a 1% false-positive rate achieved by screening with fetal nuchal translucency and maternal serum free β-hCG and PAPP-A. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

3.
This study examines 45 cases of trisomy 13 and 59 cases of trisomy 18 and reports an algorithm to identify pregnancies with a fetus affected by trisomy 13 or 18 by a combination of maternal age fetal nuchal translucency (NT) thickness, and maternal serum free β-hCG and PAPP-A at 11–14 weeks of gestation. In this mixed trisomy group the median MoM NT was increased at 2.819, whilst the median MoMs for free β-hCG and PAPP-A were reduced at 0.375 and 0.201 respectively. We predict that with the use of the combined trisomy 13 and 18 algorithm and a risk cut-off of 1 in 150 will for a 0.3% false positive rate allow 95% of these chromosomal defects to be identified at 11–14 weeks. Such algorithms will enhance existing first trimester screening algorithms for trisomy 21. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

4.
Trisomy 21 maternal serum marker screening has led to screening for other anomalies, including trisomy 18. Trisomy 18 is generally prenatally diagnosed because of major morphological defects. However, in up to 30% of cases ultrasound signs are unclear, and in most cases diagnosis is performed late in pregnancy. Of the different maternal serum markers, PAPP-A is now considered as the best for trisomy 18 screening. However, pregnancy-associated plasma protein A (PAPP-A) is of value in first trimester screening for trisomy 21, but not in the second trimester. We therefore propose a two-step screening strategy. Based on 45 trisomy 18 cases, we confirm the values of alpha-fetoprotein (AFP) (median 0.61 MoM), free β-human chorionic gonadotrophin (β-hCG) (median 0.24 MoM) and of PAPP-A (median 0.08 MoM). In the first step, a 0.5 MoM cut-off for AFP or for free β-hCG resulted in detection of 37/45 trisomy 18 cases (82%) with a 10% false-positive rate. The second step consisted of the measurement of PAPP-A for all these false-positive cases. Using a PAPP-A cut-off of 0.5 MoM, all the 37 trisomy 18 cases were detected, but now with a 0.1–0.2% false-positive rate. Amniocentesis was only offered to these few patients. This two-step second trimester screening will be of value for patients who have not been included in first trimester screening based on nuchal translucency (NT) measurement combined with the first trimester markers, PAPP-A and free β-hCG. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

5.
Maternal serum total activin-A concentration was measured in 45 pregnancies affected by trisomy 21 and 493 control unaffected pregnancies at 10–14 weeks of gestation. In the trisomy 21 pregnancies total activin-A concentration was significantly higher (1.36 MoM of the unaffected pregnancies) and in 16% of cases the level was above the 95th centile of normal. The log10 SD for the control group and the trisomy 21 group were 0.17 and 0.22, respectively. The median pregnancy associated plasma protein-A (PAPP-A) in this trisomy 21 series was 0.49 and for free β-hCG was 2.05. In the trisomy group there were significant positive associations between total activin-A and PAPP-A (0.6071) and free β-hCG (0.4255). The low median difference and the high overlap in values between trisomic and unaffected pregnancies make total activin-A of little practical use in first-trimester screening for trisomy 21. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

6.
In a study of 180 twin pregnancies I have examined the distribution of maternal serum free β-human chorionic gonadotrophin (β-hCG) and pregnancy-associated plasma protein-A (PAPP-A), in addition to fetal nuchal translucency thickness (NT), in twins classified as monochorionic or dichorionic, based on ultrasound appearance at 10–14 weeks of gestation. In 45 monochorionic and 135 dichorionic twin pregnancies the median MoM free β-hCG was not significantly different (1.00 vs 1.01), whilst that for PAPP-A was lower (0.89 vs 1.01) but again with no statistical significance. Previous reports of an increased fetal NT in monochorionic twins pregnancies could not be confirmed (1.03 vs 1.00). It is concluded that the existing pseudo risk twin correction algorithm is appropriate for both monochorionic and dichorionic twins in providing accurate first trimester risks for trisomy 21. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

7.
In a series of 54 cases of pregnancies complicated by Down syndrome and 224 unaffected pregnancies we examined maternal serum levels of hyperglycosylated human chorionic gonadotrophin (HhCG) in samples collected in the first trimester (11–13 weeks) using a sialic acid-specific lectin immunoassay. We compared these levels with those of other potential first trimester serum markers [free β-hCG, pregnancy-associated plasma protein A (PAPP-A) and total hCG (ThCG)] and modeled detection rates and false-positive rates of various biochemical markers in conjunction with fetal nuchal translucency (NT) and maternal age using an maternal age standardized population. Maternal serum HhCG in cases of Down syndrome were significantly elevated (median MoM 1.97) with 24/54 (44%) of cases above the 95th centile for unaffected pregnancies. Free β-hCG was also elevated (median MoM 2.09) with 33% of cases above the 95th centile. PAPP-A levels were reduced (median MoM 0.47) with 38% below the 5th centile. ThCG levels, whilst elevated (median MoM 1.34), had only 20% of cases above the 95th centile. Maternal serum HhCG levels were not correlated with fetal NT but showed significant correlation with ThCG and free β-hCG and with PAPP-A in the Down syndrome group (r=0.536). Maternal serum HhCG levels in cases with Down syndrome had a significant correlation with gestational age, increasing as the gestation increased. When HhCG was combined together with fetal NT, PAPP-A and maternal age, at a 5% false-positive rate the modeled detection rate was 83%, some 6% lower than when free β-hCG was used and some 4% better than when ThCG was used. Maternal serum HhCG is unlikely to be of additional value when screening for Down syndrome in the first trimester. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

8.
In a group of 149 women who had undergone routine first trimester screening using fetal nuchal translucency thickness (NT) and maternal serum free β-hCG and pregnancy associated plasma protein-A (PAPP-A) in two consecutive pregnancies the within person between pregnancy biological variability of these markers has been assessed. For fetal NT there was no correlation between NT MoM in the first and second pregnancy (r=0.0800). For maternal serum free β-hCG MoM a significant correlation was observed (r=0.4174) as was also found for PAPP-A MoM (r=0.3270). The implications for such between pregnancy marker association is that women who have an increased risk of Down syndrome in their first pregnancy are 1.5–2 times more likely to repeat this event in their next pregnancy. This observation may be useful in counselling women in the first trimester screening of a subsequent pregnancy. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

9.
The aims of this study were to determine whether assumptions used in prenatal screening for Down syndrome in twin pregnancies are valid and derive estimates of risk and screening performance in twin pregnancies using observed data. Data were collected on nuchal translucency, chorionicity, pregnancy associated plasma protein-A (PAPP-A), and free ß human chorionic gonadotrophin (free ß-hCG) from 61 twin pregnancies with Down syndrome and 7302 unaffected twin pregnancies. Distribution parameters were determined and used to estimate screening performance. The assumption that proportional differences in serum marker levels in affected and unaffected singleton pregnancies apply to twin pregnancies was not confirmed. Median free β-hCG value in monochorionic affected twin pregnancies (2.63 multiples of the median [MoM]; 95% CI, 1.79-3.22 MoM) was lower than that assuming proportionality (3.76 MoM), and the median PAPP-A value in dichorionic affected twin pregnancies (1.88 MoM; 95% CI, 1.60-2.17 MoM) was higher than that based on proportionality (1.33 MoM). The detection rate was 87% for a 3% false-positive rate in monochorionic twin pregnancies and 74% in dichorionic twin pregnancies compared with 86% in singleton pregnancies. Estimates of screening performance in Down syndrome twin pregnancies do not need to rely on assumptions and can take account of chorionicity and gestational age.  相似文献   

10.
In pregnancies obtained after assisted reproduction the false-positive rate of second trimester Down syndrome (DS) screening is increased by 1.5–3-fold. This may cause an increase in the number of amniocenteses and the fetal loss rate. The present study for the first time examined whether assisted reproductive technologies affect the results of first trimester screening. The markers PAPP-A, free β-hCG and the nuchal translucency (NT) thickness were examined at 12–14 weeks' gestation. Screening markers in 47 in vitro fertilisation (IVF), 63 ovulation induction (OI) and 3026 spontaneously conceived singleton pregnancies were compared. The MoM (multiples of the median) value in the IVF pregnancies was 1.02 (95% CI: 0.85–1.22) for PAPP-A, 1.14 (95% CI: 0.95–1.37) for β-hCG and 0.97 (95% CI: 0.89–1.05) for NT; the MoM value in the OI pregnancies was 0.89 (95% CI: 0.76–1.05) for PAPP-A, 1.08 (95% CI: 0.93–1.25) for β-hCG and 1.02 (95% CI: 0.95–1.11) for NT. The first trimester marker values in assisted reproductive pregnancies and spontaneously conceived pregnancies were not significantly different. Estimated false-positive rates for a risk cut-off of 1:400 varied from 4.7% in IVF pregnancies to 5.1% in OI pregnancies. Therefore the false-positive rate in Down syndrome screening should be independent of the method of conception. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

11.
First-trimester maternal serum alpha-fetoprotein (AFP) and human chorionic gonadotropin (HCG) levels were measured in samples from 29 women with cytogenetically abnormal pregnancies and 145 women with cytogenetically normal pregnancies matched for gestational age, race, and sample storage time. All patients had a risk of fetal aneuploidy greater than or equal to that of a mother 35 years of age. AFP was significantly lower in samples from pregnancies affected with trisomy 21 (0.67 MoM;p <0.05), while HCG values were no different from those of matched controls. Trisomies 13 and 18 could not be distinguished from matched controls by AFP. However, levels of HCG were significantly lower in such pregnancy samples, with median values of 0.65 MoM in trisomy 13 and 0.32 MoM in trisomy 18 (p<0.05). Variations in AFP and HCG levels suggest that expressed differences between autosomal aneuploidies include differences in fetal and placenta! protein production in the first trimester.  相似文献   

12.
Maternal serum and amniotic fluid alpha-fetoprotein levels were studied retrospectively in a total of 58 pregnancies with trisomy 18. In those pregnancies uncomplicated by either fetal exomphalos or neural tube defect the midtrimester maternal serum alpha-fetoprotein (MSAFP) levels were markedly reduced, the median value for 38 such pregnancies being 0.6 multiples of the median (MoM). Trisomy 18 with exomphalos was associated with a higher median MSAFP, but still within the normal range: 1.1 MoM, (nine pregnancies); trisomy 18 with exomphalos and neural tube defect (NTD) was associated with grossly raised levels: median MSAFP was 4-5 MoM (three pregnancies). Amniotic fluid alpha-fetoprotein (AFAFP) levels were normal in uncomplicated trisomy 18 pregnancies: median AFAFP, for 19 pregnancies, was 1.1 MoM. Exomphalos alone, or together with neural tube defect, was associated with greatly elevated levels of AFAFP; for exomphalos alone median AFAFP was 9.59 MoM (four pregnancies), and for exomphalos with neural tube defect the median AFAFP was 23.95 Mom (three pregnancies). Screening with low and high MSAFP, routine ultrasound, and amniocentesis on all women aged 35 years or over, together might identify over 50 per cent of pregnancies with trisomy 18.  相似文献   

13.
A study was performed to investigate the concentrations of the α and β free sub-units of human chorionic gonadotrophin (free α-hCG and free β-hCG) in maternal serum between 15 and 22 weeks of pregnancy in 126 pregnancies among 92 women with insulin-dependent diabetes mellitus (IDDM). Each IDDM pregnancy was matched with two control singleton pregnancies for gestational age (same completed week) and duration of sample storage (same calendar quarter). The median free α-hCG level in the IDDM pregnancies was 0·86 multiples of the median (MOM) for pregnancies without IDDM at the same gestational age (P<0·002) (95 per cent confidence interval 0·80–0·94). The corresponding free β-hCG level was 0·96 MOM (95 per cent confidence interval 0·85–1·09). These results enable free α-hCG values to be adjusted so that antenatal screening for Down's syndrome can be performed using this marker in IDDM pregnancies as well as in non-diabetic pregnancies.  相似文献   

14.
Over the past three years approximately 12 000 women have been screened in the first trimester through our OSCAR programme, which utilizes fetal NT and maternal serum free β-hCG and PAPP-A. During this time 30 cases of Down syndrome were identified either prenatally or postnatally. Using an established procedure the accuracy of predicted risk for Down syndrome was assessed in a population of 30 cases of Down syndrome and 11 758 unaffected pregnancies. The correlation between predicted risk and prevalence of Down syndrome was very high (r=0.9995). It is concluded that risks produced by the Fetal Medicine Foundation combined risk algorithm agree very closely with Down syndrome prevalence and can be used with confidence when counselling women of their risk. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

15.
The Dutch Working Party on Prenatal Diagnosis has initiated a study on the possibilities of first-trimester screening for fetal chromosomal disorders. We report on maternal serum human chorionic gonadotrophin (MS-hCG) measurements in 1348 pregnancies with a chromosomally normal fetus and 53 pregnancies with a chromosomally abnormal fetus. The median MS-hCG concentration in 24 pregnancies with Down's syndrome was 1.19 multiples of the normal median (MoM). The MS-hCG distributions in normal and Down's syndrome pregnancies did not differ significantly (t-test: t = 1.945, p >0.05). We also found no difference between normal pregnancies and pregnancies with other chromosomal disorders (six cases of trisomy 18, MoM = 0.80; four cases of sex chromosome abnormality, MoM = 1.01; 17 cases of chromosomal mosaicism in chorionic villi, MoM = 1.11). Selecting an upper limit at the 90th centile could detect 25 per cent of pregnancies with Down's syndrome. We conclude that, in the first trimester, MS-hCG as a screening factor for Down's syndrome is of minor value. However, MS-hCG could be a useful factor in a first-trimester screening programme based on a combination of markers.  相似文献   

16.
Serum measurements of pregnancy-associated plasma protein A (PAPP-A) and the free β-human chorionic gonadotrophin (hCG) subunit were made in 13 women with Down syndrome (DS) pregnancies and six other women with fetal aneuploidy ascertained at chorionic villus sampling (CVS), as well as 89 women with contemporaneous normal control pregnancies. Median serum PAPP-A measurements (0·31 MOM, 95 per cent confidence interval (CI) 0·22–0·65 vs. normal 1·06, 95 per cent CI 0·89–1·20) were lower and free β-hCG subunit measurements (1·13 MOM, 95 per cent CI 0·93–2·63 vs. normal 0·91, 95 per cent CI 0·79–1·03) were higher at statistically significant levels. Receiver operator characteristic (ROC) curves showed that the highest sensitivity for detection, 71·2 per cent (95 per cent CI 54·7–87·6 per cent), was for depressed PAPP-A levels; the combination of low serum PAPP-A levels, maternal age, and elevated free β-hCG levels yielded a detection rate of 78·9 per cent (95 per cent CI 64·9–92·8 per cent) of the affected pregnancies at 8–12 weeks' gestation.  相似文献   

17.
Maternal serum levels of human chorionic gonadotrophin and its subunits (intact, α, and free βhCG) and pregnancy-associated plasma protein A (PAPP-A) were measured in 279 women between 8 and 14 weeks' gestation. This group included 23 pregnancies in which the fetus had Down syndrome (DS), diagnosed either at birth or during the second trimester (n=17) or from chorionic villus sampling (CVS) (n=6). Normal medians were determined from the 258 apparently normal pregnancies. The median levels of intact hCG (1·4 MOM) and free βhCG (2·1 MOM) were significantly raised, whereas the median level of PAPP-A (0·39 MOM) was significantly lower in the DS pregnancies when compared with the control group. Levels of αhCG were similar in both the control and the DS pregnancies. Analysis of samples taken prior to 14 weeks' gestation demonstrated that only PAPP-A (0·34 MOM) was significantly altered in DS pregnancies. However, after the exclusion of DS cases diagnosed at CVS, the median intact hCG (1·56 MOM), free βhCG (2·27 MOM), and αhCG (1·8 MOM) were all raised in DS pregnancies. This emphasizes the problem of the interpretation of biochemical markers when DS cases are diagnosed at CVS.  相似文献   

18.
The value of measuring the separate sub-units of human chorionic gonadotrophin (free α-hCG and free β-hCG) instead of total hCG together with alpha-fetoprotein (AFP) and unconjugated oestriol (uE3) was examined to determine the effect on the performance of serum screening for Down's syndrome between 15 and 22 weeks of pregnancy. The study was based on stored serum samples relating to 75 singleton pregnancies with fetal Down's syndrome and 367 unaffected singleton pregnancies, matched for maternal age, gestational age, and duration of storage of the serum sample, supplemented by data from 970 white women with unaffected pregnancies. Using the four serum markers AFP, uE3, free β-hCG, and free α-hCG, in addition to maternal age, 65 per cent of Down's syndrome pregnancies were detected for a 5 per cent false-positive rate compared with 59 per cent with the conventional triple test (AFP, uE3, total hCG with maternal age). If gestation was based on an ultrasound scan examination, the detection rate was 72 per cent using the four serum markers compared with 67 per cent with the triple test. As an alternative illustration, if the detection rate was kept at 60 per cent and gestation was estimated by an ultrasound scan examination the four-marker test reduced the false-positive rate by one-third from 3 per cent using the triple test to 2 per cent with the four-marker test. Screening performance was hardly affected by adjusting marker levels for maternal weight. The four-marker test is, both from a medical and from a financial perspective, the most effective method of prenatal screening for Down's syndrome suitable for routine use.  相似文献   

19.
Combined first trimester screening using pregnancy associated plasma protein-A (PAPP-A), free β-human chorionic gonadotrophin, and nuchal translucency (NT), is currently accepted as probably the best combination for the detection of Down syndrome (DS). Current first trimester algorithms provide computed risks only for DS. However, low PAPP-A is also associated with other chromosome anomalies such as trisomy 13, 18, and sex chromosome aneuploidy. Thus, using currently available algorithms, some chromosome anomalies may not be detected. The purpose of the present study was to establish a low-end cut-off value for PAPP-A that would increase the detection rates for non-DS chromosome anomalies. The study included 1408 patients who underwent combined first trimester screening. To determine a low-end cut-off value for PAPP-A, a Receiver–Operator Characteristic (ROC) curve analysis was performed. In the entire study group there were 18 cases of chromosome anomalies (trisomy 21, 13, 18, sex chromosome anomalies), 14 of which were among screen-positive patients, a detection rate of 77.7% for all chromosome anomalies (95% CI: 55.7–99.7%). ROC curve analysis detected a statistically significant cut-off for PAPP-A at 0.25 MoM. If the definition of screen-positive were to also include patients with PAPP-A<0.25 MoM, the detection rate would increase to 88.8% for all chromosome anomalies (95% CI: 71.6–106%). This low cut-off value may be used until specific algorithms are implemented for non-Down syndrome aneuploidy. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

20.
Risks appropriate for mid-trimester prenatal screening for autosomal trisomies have been estimated from a combination of maternal age and maternal serum (MS) alpha-fetoprotein (AFP) levels at 16–20 weeks gestation. Published data on the frequency of Down's syndrome births relative to maternal age were modified to include the additional age-related frequency of trisomy 18 and trisomy 13 cases to provide an overall risk for an autosomal trisomy at midtrimester. MSAFP results from a retrospective study of 142 affected (114 trisomy 21, 19 trisomy 18, and 9 trisomy 13)and 113 000 unaffected pregnancies were converted to multiples of the appropriate gestational median (MOM). The AFP levels in the autosomal trisomy pregnancies were found to be significantly reduced at 0.72 MOM of the unaffected pregnancies. Risks (likelihood ratios) were derived from the overlapping log Gaussian distributions for affected and unaffected pregnancies and combined with maternal age risks to give the overall odds of an affected pregnancy. A mid-trimester cut-off risk of 1:280 gave an estimated 37 per cent detection rate for autosomal trisomies in the west of Scotland population for a follow-up (false-positive) rate of 6.6 per cent. These figures compare with a 30 per cent detection and 6.7 per cent false-positive rate if age 35 years and over is used as the sole criterion for selection of at-risk pregnancies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号