首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 142 毫秒
1.
Indoor radon survey and gamma activity measurements in soil samples were carried out in the Giresun province (Northeastern Turkey). The result of analysis of variance showed a relationship between indoor radon and radium content in soil (R(2)=0.54). It was found that indoor radon activity concentration ranged from 52 to 360 Bq m(-3) with an average value of 130 Bq m(-3). A model built by BEIR VI was used to predict the number of lung cancer deaths due to indoor radon exposure. It was found that indoor radon is responsible for 8% of all lung cancer deaths occurring in this province. (137)Cs activity concentration was measured 21 years after the Chernobyl accident. The results showed that (137)Cs activity concentration ranged from 41 to 1304 Bq kg(-1) with an average value of 307 Bq kg(-1). The indoor radon results and the geology of the studied area were discussed. Annual effective doses to the both radionuclides of natural origin and (137)Cs were estimated.  相似文献   

2.
The aim of this work was to make a comparison of indoor radon concentrations in dwellings and in soil air in the area of two geological formations in the Suwa?ki region (Poland). The mean arithmetic airborne concentration was found to be the highest (301 Bq m (-3)) in the basements of buildings in the gravel and sand areas, whereas in the boulder clay areas it reached 587 Bq m (-3). Out of 54 measurements of radon concentrations performed at the ground floor, in eight cases concentrations were found to exceed 200 Bq m (-3) - permissible radon level in new-built houses in Poland and in three cases these values were even higher than 400 Bq m (-3). The highest radon levels were noted in houses with earthen basement floors and with direct entrance from the basement to rooms or kitchens. The mean arithmetic radon concentration in the soil air in the sandy and gravel formations was 39.7 kBq m (-3) and in clay formation it was 26.5 kBq m (-3). Higher radon levels were also found in the water obtained from household wells reaching 8367 Bq m (-3) as compared with tap water (2690 Bqm (-3)). The mean indoor concentration for the whole area under study was found to be 169.4 Bq m (-3), which is higher than the mean value for Poland (49.1 Bq m (-3)) by a factor of 3.5.  相似文献   

3.
Specific activities of the natural radionuclides (238)U, (226)Ra, (232)Th and (40)K were measured by means of gamma-ray spectrometry in surface soil samples collected from the city of Ptolemais, which is located near lignite-fired power plants. The mean activity values for (238)U, (226)Ra, (232)Th and (40)K were found to be 42+/-11, 27+/-6, 36+/-5 and 496+/-56 Bq kg(-1), respectively. These values fall within the range of typical world and Greek values for soil. The indoor radon concentration levels, which were also measured in 66 dwellings by means of SSNTD, ranged from 12 to 129 Bq m(-3), with an average value of 36+/-2 Bq m(-3). This value is close to world and Greek average values for indoor radon concentrations. The total effective dose due to outdoor external irradiation of terrestrial origin and to indoor internal irradiation from the short-lived decay products of (222)Rn was estimated to be 1.2 mSv y(-1) for adults, which is lower than the global effective dose due to natural sources of 2.4 mSv y(-1).  相似文献   

4.
The aim of the study was to compare radon concentrations in neighbouring hospital buildings which were constructed in different years during the period 1963-2000 and are located in areas with similar radon potential. The value of arithmetic mean (AM) radon concentration in soil gas amounted to 14,464 Bq m(-3). In a hospital built 40 years ago, the AM radon concentration in the cellar was 38.4+/-36.7 Bq m(-3) and on higher levels it was 17.1+/-10.3 Bq m(-3). In a hospital built 16 years ago, these values equaled 45.5+/-47.2 Bq m(-3) and 20.4+/-12.5 Bq m(-3), respectively. In the newest hospital, built three years ago, radon concentration (AM) in a cellar was 32.3+/-27.4 Bq m(-3) and the respective value on higher levels amounted to 20.4+/-12.6 Bq m(-3). When comparing radon concentrations in the cellars, no statistically significant differences were found. Similarly, no statistically significant differences were observed between radon concentrations measured on higher levels in investigated hospital buildings.  相似文献   

5.
This paper reports on radon concentrations in dwellings from fifty different locations of India. The incorporated data were obtained using the passive solid state nuclear track detector technique. The estimated geometric mean value for India is 67.1 Bq m(-3). Chuadanga in Bangladesh had the lowest observed indoor radon concentration of 27.3 Bq m(-3) and Una in the northern part of India had the highest concentration of 281.5 Bq m(-3). This paper discusses the national geometrical mean value in terms of the national geometric mean values of other countries and also in terms of the geological influence. The estimated indoor radon levels are compared with the indoor radon levels as recommended by the International Commission on Radiation Protection (ICRP). It was observed that there are several locations in India where dwellings have higher indoor radon levels than the ICRP recommended value and requires some sort of intervention from regulating authorities. The mean value for indoor radon level given in the report of UNSCEAR 2000 for India needs to be revised.  相似文献   

6.
Radon levels in atmospheric and aquatic systems in Cyprus have recently been measured using the radon monitor Alpha Guard. Indoor and outdoor radon levels were obtained in situ, whereas analysis of radon concentrations in water was performed using tap and ground water samples collected from several areas of the island. The average value for outdoor and indoor radon concentration is 11+/-10 and 7+/-6 Bq m(-3), respectively, and for tap and ground water 0.4 Bq l(-1) and 1.4 Bq l(-1), respectively. From these data the annual dose equivalent of airborne radon to the Cypriot population is about 0.19 mSv y(-1), which is quite low compared to the total dose equivalent of natural and man-made ionising radiation in Cyprus. Radon levels in aquatic systems are relatively low due to an exhaustive utilisation of ground water resources and also to the increased input of desalinated sea water in the water distribution network and eventually into the ground water reservoirs.  相似文献   

7.
Measurements of indoor radon concentrations were performed in 28 low-rise houses and 30 apartments in Patras area from December 1996 to November 1997, using nuclear track detectors. The investigation was focused on the effects of season and floor number, as well as on the existence of a basement in low-rise houses on indoor radon levels. It was found that the differences in mean radon concentrations between adjacent seasons, in a number of 61 selected sampling sites distributed in 28 houses, were statistically significant. As expected, a maximum was found in winter and a minimum in summer. The differences in mean radon concentration on different floors of the same houses were also statistically significant and followed a linear decrease from underground to 2nd floor. In addition, indoor radon concentrations in the ground floor were found to be influenced by the existence or not of a basement. The average annual radon concentration was found to be 41 Bq m(-3) for the houses, 28 Bq m(-3) for the apartments and 38 Bq m(-3) for all the dwellings. These values lead to an average effective dose equivalent of 1.1, 0.7 and 0.9 mSv y(-1), respectively. Residents living on the underground in low-rise houses, during winter, where the average effective dose equivalent is 2.1 mSv y(-1), attain the higher risk.  相似文献   

8.
Radon-222 in Brazil: an outline of indoor and outdoor measurements   总被引:3,自引:0,他引:3  
This study discusses the methodology for measuring and assessing the radon concentration in indoor and outdoor environments. A research study was developed to investigate the long-term behavior of the diurnal and seasonal fluctuations of radon (222)Rn EEC (Equilibrium-Equivalent Concentration) and the influence of temperature and other climatic aspects on this behavior. The study was performed by means of both integrated and instantaneous measurements of radon and its short-lived daughter products for a period of 1 year in an indoor environment in Rio de Janeiro city, Brazil (reference environment), with continuous measurement, using a radon monitor with an alpha spectrometry detector.For a single day, a variability of about 50% could be observed in the (222)Rn EEC values measured on a hourly basis, with a maximum occurring early in the morning and a minimum in the afternoon. For the long-term period, seasonality is responsible for a two order of magnitude variability, with a maximum of 50 Bq.m(-3) in winter (dry season) and a minimum of 0.5 Bq.m(-3) in the summer months (wet season), outdoors. A negative correlation with temperature was observed. The conclusions of this experiment led to a survey of radon gas concentration in dwellings in Rio de Janeiro city, Brazil, in urban area with nearly 7 million inhabitants, through integrated sampling methods, using a Solid State Nuclear Track Detectors Technique (SSNTD). The study was conducted in different geomorphological locations in town. The radon gas concentration in Rio de Janeiro dwellings ranged from 5 Bq.m(-3) to 200 Bq.m(-3). A good correlation between indoor radon gas concentration and location of dwellings was observed. The seashore areas presented the lowest levels of indoor radon concentration, whereas the highest levels were found close to the mountains.  相似文献   

9.
High-resolution gamma spectrometry was used to determine the concentration of 40K, 238U and 232Th series in soil samples taken from areas surrounding the city of Aldama, in Chihuahua. Results of indoor air short-time sampling, with diffusion barrier charcoal detectors, revealed relatively high indoor radon levels, ranging from 29 to 422 Bq/m3; the radon concentrations detected exceeded 148 Bq/m3 in 76% of the homes tested. Additionally, liquid scintillation counting showed concentrations of radon in drinking water ranging from 4.3 to 42 kBq/m3. The high activity of 238U in soil found in some places may be a result of the uranium milling process performed 20 years ago in the area. High radon concentrations indoor and in water may be explained by assuming the presence of uranium-bearing rocks underneath of the city, similar to a felsic dike located near Aldama. The estimated annual effective dose of gamma radiation from the soil and radon inhalation was 3.83 mSv.  相似文献   

10.
A radon survey has been carried out around the town of Niska Banja (Serbia) in a region partly located over travertine formations, showing an enhanced level of natural radioactivity. Outdoor and indoor radon concentrations were measured seasonally over the whole year, using CR-39 diffusion type radon detectors. Outdoor measurements were performed at 56 points distributed over both travertine and alluvium sediment formations. Indoor radon concentrations were measured in 102 living rooms and bedrooms of 65 family houses. In about 50% of all measurement sites, radon concentration was measured over each season separately, making it possible to estimate seasonal variations, which were then used to correct values measured over different periods, and to estimate annual values. The average annual indoor radon concentration was estimated at over 1500 Bq/m3 and at about 650 Bq/m3 in parts of Niska Banja located over travertine and alluvium sediment formations, respectively, with maximum values exceeding 6000 Bq/m3. The average value of outdoor annual radon concentration was 57 Bq/m3, with a maximum value of 168 Bq/m3. The high values of indoor and outdoor radon concentrations found at Niska Banja make this region a high natural background radiation area. Statistical analysis of our data confirms that the level of indoor radon concentration depends primarily on the underlying soil and building characteristics.  相似文献   

11.
Radon (Rn(222)) levels in an indoor atmosphere of a multi-storey building at Mumbai have been measured for one year covering all the four seasons. Monitoring was carried out using the time-integrated passive detector technique, using Kodak-115 type Solid State Nuclear Track Detector (SSNTD) films of 2.5x2.5 cm size. Measured indoor radon levels showed a decreasing trend with height with concentration ranging from 41 Bq m(-3) at ground floor level to 15 Bq m(-3) at 19th floor level. Using the dose conversion factors, the inhalation dose due to breathing of radon gas is estimated to be 1.03 mSv y(-1) at the ground floor to 0.38 mSv y(-1) at the 19th floor level. Measured indoor radon concentrations on each floor were compared with the computed values using a mathematical model. The agreement between measured values and calculated values of indoor concentrations at different floors was very good within the limitations of various field parameter values.  相似文献   

12.
In the Harghita volcanic range (Romania) there are many occurrences of dry CO(2) emanations, called mofettes. The emanating gas with high carbon dioxide content has a proved curative effect. The gas also contains important quantities of radon. Since the mofettes are used in curative purposes in several illnesses, in most of the cases without medical supervising, has been proposed to determine the radon activity concentration in some of the most frequented mofettes from Romania. The seasonal variations have also been monitored and were calculated the effective doses received by the patients during a cure. The radon activity concentrations' levels above the mofettes indoor air range between 548 and 10 717Bq/m(3) while within the gas pools' values between 3210 and 32 781Bq/m(3) have been measured. The effective dose received by the patients during a cure is between 0.0086 and 0.16mSv. No major seasonal variations of the radon activity concentrations levels have been pointed out so far in the studied mofettes.  相似文献   

13.
The concentration of radon-222 has been monitored since 1995 in the atmosphere of a 2 m transverse dimension, 128 m long, dead-end horizontal tunnel located in the French Alps, at an altitude of 1600 m. Most of the time, the radon concentration is stable, with an average value ranging from 200 Bq m(-3) near the entrance to about 1000 Bq m(-3) in the most confined section, with an equilibrium factor between radon and its short-lived decay products varying from 0.61 to 0.78. However, radon bursts are repeatedly observed, with amplitudes reaching up to 36 x 10(3) Bq m(-3) and durations varying from one to several weeks, with similar spatial variations along the tunnel as the background concentration. These spatial variations are qualitatively interpreted in terms of natural ventilation. Comparing the radon background concentration with the measured radon exhalation flux at the wall yields an estimate of 8+/-2 x 10(-6) s(-1) (0.03+/-0.007 h(-1)) for the ventilation rate. The hypothesis that the bursts could be due to transient changes in ventilation can be ruled out. Thus, the bursts are the results of transient increased radon exhalation at the walls, that could be due to meteorological effects or possibly combined hydrological and mechanical forcing associated with the water level variations of the nearby Roselend reservoir lake. Such studies are of interest for radiation protection in poorly ventilated underground settings, and, ultimately, for a better understanding of radon exhalation associated with tectonic or volcanic processes.  相似文献   

14.
The paper presents the results of indoor radon concentration survey in 201 homes and offices in Niska Banja (the Spa of Nis), a well-known health resort and a spa in the South-East of Serbia. Radon indoor concentrations were determined by active charcoal method, according to standard EPA procedure. The indoor radon concentrations were in the range of up to 200 Bq/m(3) (47%), from 200-600 Bq/m(3) (26%) and over 600 Bq/m(3) (27%). Three areas of extremely high average radon concentrations were found (1,340-4,340 Bq/m(3)), with a maximum above 13,000 Bq/m(3). The content of natural radionuclides ((226)Ra, (214)Pb, (214)Bi, (235)U, (228)Ac, (212)Pb, (212)Bi, (208)Tl, (40)K) and (137)Cs, as well as the content of total uranium, thorium and potassium in mud used in peloidotherapy in the Health Institute "Niska Banja" was determined, too. The activities of the radionuclides were determined on an HPGe detector, by standard gamma spectroscopy. The results indicated considerably high amounts of total uranium and thorium (0.021 g/kg mud and 0.003 g/kg mud, respectively), due to the karsts origin of the soil.  相似文献   

15.
Evaluation was made of the distribution of radon gas and radiation exposure rates in the four main natural gas treatment facilities in Syria. The results showed that radiation exposure rates at contact of all equipment were within the natural levels (0.09-0.1 microSvh(-1)) except for the reflex pumps where a dose rate value of 3 microSvh(-1) was recorded. Radon concentrations in Syrian natural gas varied between 15.4 Bq m(-3) and 1141 Bq m(-3); natural gas associated with oil production was found to contain higher concentrations than the non-associated natural gas. In addition, radon concentrations were higher in the central processing facilities than the wellheads; these high levels are due to pressurizing and concentrating processes that enhance radon gas and its decay products. Moreover, the lowest 222Rn concentration was in the natural gas fraction used for producing sulfur; a value of 80 Bq m(-3) was observed. On the other hand, maximum radon gas and its decay product concentrations in workplace air environments were found to be relatively high in the gas analysis laboratories; a value of 458 Bq m(-3) was observed. However, all reported levels in the workplaces in the four main stations were below the action level set by IAEA for chronic exposure situations involving radon, which is 1000 Bq m(-3).  相似文献   

16.
The concentrations of 222Rn (radon) and its progeny with surrounding environmental gamma-dose rates were measured simultaneously inside and outside of buildings at 10 locations around Taipei and Hualien in Taiwan. For summer radon in Taiwan, indoor concentrations were estimated to be about 20 Bq m(-3) with about 90 nSv h- of environmental gamma, and outdoors, about 10 Bq m(-3) with about 70 nSv h(-1). The equilibrium factors were calculated to be 0.2-0.3 indoors and 0.3-0.4 outdoors. Indoor radon concentration had a weak positive correlation with gamma-dose rate. Since there is a possibility that high radon concentrations exist indoors during the cool season in Taiwan because of extremely low ventilation rates in the dwellings, a winter survey in January through February will be needed for future estimation of the annual effective dose.  相似文献   

17.
Nationwide outdoor radon (222Rn) concentrations in Japan were measured to survey the environmental outdoor 222Rn level and to estimate the effective dose to the general public from 222Rn and its progeny. The 222Rn concentration was measured with a passive-type radon monitor. The 222Rn monitors were installed at about 700 points throughout Japan from 1997 to 1999. The annual mean 222Rn concentration in Japan was estimated from four quarters measurements of 47 prefectures in Japan. Nationwide outdoor mean 222Rn concentration was 6.1 Bq m(-3). This was about 40% of the indoor 222Rn concentration in Japan. The 222Rn concentration in Japan ranged from 3.3 Bq m(-3) in the Okinawa region to 9.8 Bq m(-3) in the Chugoku region, reflecting geological characteristics. Seasonal variation of outdoor 222Rn concentration was also found to be lowest in July to September, and highest in October to December. From the results of this 222Rn survey and previous indoor 222Rn survey program, the effective dose to the general public from 222Rn and its progeny was estimated to be 0.45 mSv y(-1).  相似文献   

18.
To quantify the effectiveness of Sub-Slab Depressurisation, widely used in the United Kingdom (U.K.) to mitigate indoor radon gas levels in residential properties, a study was made of radon concentration data collected from a set of 170 homes situated in Radon Affected Areas in Northamptonshire and neighbouring counties, remediated using conventional sump/pump technology. A high incidence of satisfactory remediation outcomes was achieved, with 100% of the houses remediated demonstrating post-remediation radon concentrations below the U.K. domestic Action Level of 200 Bq m(-3), while more than 75% of the sample exhibited radon mitigation factors (defined as the ratio of radon concentrations following and prior to remediation) <0.2. Two systematic trends are identified. Firstly, absolute radon concentration reduction following remediation is directly proportional to initial radon concentration, with a mean reduction factor of 0.96 and a residual component of around 75 Bq m(-3). Secondly, houses with lower initial radon concentrations demonstrate poorer (higher) mitigation factors. These observations support a model in which the total indoor radon concentration within a dwelling can be represented by two principal components, one susceptible to mitigation by sub-slab depressurisation, the other remaining essentially unaffected. The first component can be identified with radon emanating from the subsoil and bedrock geologies, percolating through the foundations of the dwelling as a component of the soil-gas, and potentially capable of being attenuated by sub-slab depressurisation or radon-barrier remediation technologies. The second contribution can be identified with radon emanating from materials used in the construction of the dwelling with a further contribution from the natural background level, and is essentially unaffected by ground-level remediation strategies. Modelling of a multi-component radon dependency using ground-radon attenuation factors derived from the experimental data, in conjunction with typical background and structural-radon levels, yields behaviour in good agreement with the observed dependence of mitigation factor on initial radon concentration.  相似文献   

19.
Results of indoor gamma radiation and radon measurements in 95 wooden dwellings located in a Norwegian thorium-rich carbonatite area using thermoluminescent dosemeters and CR-39 alpha track detectors, respectively, are reported together with a thorough analysis of the indoor data with regard to geological factors. Slightly enhanced radium levels and thorium concentrations of several thousands Bq kg(-1) in the carbonatites were found to cause elevated indoor radon-222 levels and the highest indoor gamma dose rates ever reported from wooden houses in Norway. An arithmetic mean indoor gamma dose rate of 200 nGy h(-1) and a maximum of 620 nGy h(-1) were obtained for the group of dwellings located directly on the most thorium-rich bedrock.  相似文献   

20.
The RAD Laboratory measured annual means of radon activity concentrations in 15 277 first-floor rooms of dwellings and in 325 rooms on upper floors in Hungary (1994-2004). The original purpose of the survey was to find radon-prone area in Hungary. The maximum measured value was 5800 Bq m(-3), while the minimum was 10 Bq m(-3). Due to geological diversity and different structures of buildings, the data set of first-floor rooms did not follow the lognormal distribution. Therefore, strata were chosen so that the measured data fitted the lognormal distribution. The numbers of dwellings above a given radon level were determined in each stratum. The national distribution was then taken as the sum of the individual distributions of all strata. This distribution was not lognormal. The parameters of the best fitting lognormal distribution were GM = 58 Bq m(-3), GSD = 2.2. The weighted averages of strata values GM = 62 Bq m(-3), GSD=2.1 were obtained corresponding to 92% of Hungarian dwellings.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号