首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
The ozone that initially presents in the previous day's afternoon mixing layer can remain in the nighttime atmosphere and then be carried over to the next morning. Finally, this ozone can be brought to the ground by downward mixing as mixing depth increases during the daytime, thereby increasing surface ozone concentrations. Variation of ozone concentration during each of these periods is investigated in this work. First, ozone concentrations existing in the daily early morning atmosphere at the altitude range of the daily maximum mixing depth (residual ozone concentrations) were measured using tethered ozonesondes on 52 experimental days during 2004-2005 in southern Taiwan. Daily downward-mixing ozone concentrations were calculated by a box model coupling the measured daily residual ozone concentrations and daily mixing depth variations. The ozone concentrations upwind in the previous day's afternoon mixing layer were estimated by the combination of back air trajectory analysis and known previous day's surface ozone distributions. Additionally, the relationship between daily downward-mixing ozone concentration and daily photochemically produced ozone concentration was examined. The latter was calculated by removing the former from daily surface maximum ozone concentration. The measured daily residual ozone concentrations distributed at 12-74 parts per billion (ppb) with an average of 42 +/- 17 ppb are well correlated with the previous upwind ozone concentration (R2 = 0.54-0.65). Approximately 60% of the previous upwind ozone was estimated to be carried over to the next morning and became the observed residual ozone. The daily downward-mixing ozone contributes 48 +/- 18% of the daily surface maximum ozone concentration, indicating that the downward-mixing ozone is as important as daily photochemically produced ozone to daily surface maximum ozone accumulation. The daily downward-mixing ozone is poorly correlated with the daily photochemically produced ozone and contributes significantly to the daily variation of surface maximum ozone concentrations (R2 = 0.19). However, the contribution of downward-mixing ozone to daily ozone variation is not included in most existing statistical models developed for predicting daily ozone variation. Finally, daily surface maximum ozone concentration is positively correlated with daily afternoon mixing depth, attributable to the downward-mixing ozone.  相似文献   

2.
To quantify the possible sources of the high ambient ozone concentration in the low troposphere over Taiwan, ozone sounding data from a two-year intensive field measurement program conducted in April and early May of 2004 and 2005 in northern Taiwan has been examined. We found that the vertical ozone distributions and occurrence of enhanced ozone in the lower troposphere (below 6 km) mainly resulted from (1)Type NE: the long-range transport of ozone controlled by the prevailing northeasterly winds below 2 km, (2)Type LO: the local photochemical ozone production process, and (3)Type SW: the strong southwest/westerly winds aloft (2–6 km). In the boundary layer (BL), where Asian continental outflow prevails, the average profile for type NE is characterized by a peak ozone concentration of nearly 65 ppb at about 1500 m altitude. For type LO, high ozone concentration with an average ozone concentration greater than 80 ppb was also found in the BL in the case of stagnant atmospheric and sunny weather conditions dominated. For type SW, significant ozone enhancement with average ozone concentration of 70–85 ppb was found at around 4 km altitude. It is about 10 ppb greater than that of the types NE and LO at the same troposphere layer owing to the contribution of the biomass burning over Indochina. Due to Taiwan's unique geographic location, the complex interaction of these ozone features in the BL and aloft, especially features associated with northeasterly and south/southwesterly winds, have resulted in complex characteristics of ozone distributions in the lower troposphere over northern Taiwan.  相似文献   

3.
Passive samplers with two different collection substrates were used to obtain an average ozone concentration for 1 month during the summer of 2002 for each South Carolina county. One sampler contained a filter coated with indigo carmine, whose color fades when exposed to ozone. The fading was measured by reflectance spectroscopy. The other sampler contained filters that were coated with nitrite, which is oxidized to nitrate when exposed to ozone. The nitrate was measured by ion chromatography. Calibration curves were developed for the two methods by comparing color fading from indigo carmine and nitrate ion concentration from the nitrite filter with ambient ozone concentration measured by a co-located reference continuous UV ozone analyzer. These curves were used to calculate integrated ozone concentrations for samplers distributed across South Carolina. Using the indigo carmine method, the average ozone concentrations ranged from 21 to 64 ppb (average = 46 +/- 7.9 ppb, n = 58) across the 46 counties in the state during one summer month of 2002. Concentrations for the same time period from the nitrite-coated filters ranged from 23 to 62 ppb (average = 41 +/- 8.1 ppb, n = 58). Also for the same time period, the 23 continuous UV photometric ozone monitors operated by the South Carolina Department of Health and Environmental Control at sites within 10 miles of some of the passive monitors showed ozone concentrations ranging from 28 to 50 ppb (average = 39 +/- 6.3 ppb, n = 22).  相似文献   

4.
Abstract

To evaluate methods of reducing exposure of school children in southwest Mexico City to ambient ozone, outdoor ozone levels were compared to indoor levels under three distinct classroom conditions: windows/doors open, air cleaner off; windows/doors closed, air cleaner off; windows/ doors closed, air cleaner on. Repeated two-minute average measurements of ozone were made within five minutes of each other inside and outside of six different school classrooms while children were in the room. Outdoor ozone two-minute average levels varied between 64 and 361 ppb; mean outdoor levels were above 160 ppb for each of the three conditions. Adjusting for outdoor relative humidity, for a mean outdoor ozone concentration of 170 ppb, the mean predicted indoor ozone concentrations were 125.3 (±5.7) ppb with windows/doors open; 35.4 (±4.6) ppb with windows/ doors closed, air cleaner off; and 28.9 (±4.3) ppb with windows/ doors closed, air cleaner on. The mean predicted ratios of indoor to outdoor ozone concentrations were 0.71 (±0.03) with windows/doors open; 0.18 (±0.02) ppb with windows/doors closed, air cleaner off; and 0.15 (±0.02) ppb with windows/doors closed, air cleaner on. As outdoor ozone concentrations increased, indoor ozone concentrations increased more rapidly with windows and doors open than with windows and doors closed. Ozone exposure in Mexican schools may be significantly reduced, and can usually be kept below the World Health Organization (WHO) guideline of 80 ppb, by closing windows and doors even when ambient ozone levels reach 30Q ppb or more.  相似文献   

5.
Abstract

Passive samplers with two different collection substrates were used to obtain an average ozone concentration for 1 month during the summer of 2002 for each South Carolina county. One sampler contained a filter coated with indigo carmine, whose color fades when exposed to ozone. The fading was measured by reflectance spectroscopy. The other sampler contained filters that were coated with nitrite, which is oxidized to nitrate when exposed to ozone. The nitrate was measured by ion chromatography.

Calibration curves were developed for the two methods by comparing color fading from indigo carmine and nitrate ion concentration from the nitrite filter with ambient ozone concentration measured by a co-located reference continuous UV ozone analyzer. These curves were used to calculate integrated ozone concentrations for samplers distributed across South Carolina.

Using the indigo carmine method, the average ozone concentrations ranged from 21 to 64 ppb (average = 46 ± 7.9 ppb, n = 58) across the 46 counties in the state during one summer month of 2002. Concentrations for the same time period from the nitrite-coated filters ranged from 23 to 62 ppb (average = 41 ± 8.1 ppb, n = 58). Also for the same time period, the 23 continuous UV photometric ozone monitors operated by the South Carolina Department of Health and Environmental Control at sites within 10 miles of some of the passive monitors showed ozone concentrations ranging from 28 to 50 ppb (average = 39 ± 6.3 ppb, n = 22).  相似文献   

6.
Using the differential optical absorption spectroscopy (DOAS) technique and a Fourier transform spectrometer, NO2, SO2, O3, benzene. and toluene were measured during three measurement campaigns held in Brussels in 1995, 1996, and 1997. The O3 concentrations could be explained as the results of the local photochemistry and the dynamical properties of the mixing layer. NO2 concentrations were anti-correlated to the O3 concentrations, as expected. SO2 also showed a pronounced dependence on car traffic. Average benzene and toluene concentrations were, respectively 1.7 ppb and between 4.4 and 6.6 pbb, but high values of toluene up to 98.8 ppb were observed. SO2 concentrations and to a lesser extent, those of NO2 and 03, were dependent on the wind direction. Ozone in Brussels has been found to be influenced by the meteorological conditions prevailing in central Europe. Comparisons with other measurements have shown that 03 and SO2 data are in general in good agreement, but our NO2 concentrations seem to be generally higher.  相似文献   

7.
Abstract

A research site for atmospheric chemistry and air pollution measurements was established at Pinnacle State Park in Addison, NY, in 1995. This paper presents an overview of the site characteristics and measurement program, as well as monthly average concentrations for many of the trace gas and aerosol pollutants over the full measurement period. Monthly averaged ozone concentrations range from values as low as 15 parts per billion (ppb) during cold-season months, to values approaching 50 ppb during some spring and summer months. Sulfur dioxide (SO2), oxides of nitrogen (NOx), and reactive odd nitrogen (NOy) all show distinct seasonal variation, with summertime monthly averages as low as 1–3 ppb, and wintertime monthly averages from 6–12 ppb. The variation in carbon monoxide (CO) is much smaller, with minimums of approximately 150 ppb and maximums only rarely exceeding 250 ppb. Data for three hydrocarbon species propane, benzene, and isoprene—are presented. Propane and benzene show higher monthly averaged concentrations in the winter and lower values in the summer, with values ranging over a factor of 4–5. Isoprene, on the other hand has much higher values during the summer season, sometimes a factor of 10 or more greater than concentrations measured in the winter. Monthly averaged plots for fine particulate matter (PM2.5) beginning in 1999 show a robust summer maximum and winter minimum, and roughly a factor of two difference between the two. An empirical measure of ozone production using the correlation of hour-averaged ozone and NOy data illustrates relatively robust ozone production during some, but not all, summertime months over the time period. Also, an analysis of the frequency distribution of the hours of maximum ozone concentration shows a strong mid-afternoon peak, as expected, but also a prominent secondary maximum centered around midnight. The secondary peak is interpreted as ozone transported from ozone-producing areas to the west, including Buffalo, Cleveland, Pittsburgh, and the Ohio Valley. Finally, SO2 concentrations as a function of wind direction clearly indicate maximum impacts when the winds are out of the south (Pittsburgh and Philadelphia), with a secondary peak when the winds are from the north-northeast, consistent with the locations of major SO2 emission sources in the region.  相似文献   

8.
A spatially and temporally resolved biogenic hydrocarbon and nitrogen oxides (NOx) emissions inventory has been developed for a region along the Mexico-U.S. border area. Average daily biogenic non-methane organic gases (NMOG) emissions for the 1700 x 1000 km2 domain were estimated at 23,800 metric tons/day (62% from Mexico and 38% from the United States), and biogenic NOx was estimated at 1230 metric tons/day (54% from Mexico and 46% from the United States) for the July 18-20, 1993, ozone episode. The biogenic NMOG represented 74% of the total NMOG emissions, and biogenic NOx was 14% of the total NOx. The CIT photochemical airshed model was used to assess how biogenic emissions impact air quality. Predicted ground-level ozone increased by 5-10 ppb in most rural areas, 10-20 ppb near urban centers, and 20-30 ppb immediately downwind of the urban centers compared to simulations in which only anthropogenic emissions were used. A sensitivity analysis of predicted ozone concentration to emissions was performed using the decoupled direct method for three dimensional air quality models (DDM-3D). The highest positive sensitivity of ground-level ozone concentration to biogenic volatile organic compound (VOC) emissions (i.e., increasing biogenic VOC emissions results in increasing ozone concentrations) was predicted to be in locations with high NOx levels, (i.e., the urban areas). One urban center--Houston--was predicted to have a slight negative sensitivity to biogenic NO emissions (i.e., increasing biogenic NO emissions results in decreasing local ozone concentrations). The highest sensitivities of ozone concentrations to on-road mobile source VOC emissions, all positive, were mainly in the urban areas. The highest sensitivities of ozone concentrations to on-road mobile source NOx emissions were predicted in both urban (either positive or negative sensitivities) and rural (positive sensitivities) locations.  相似文献   

9.
Ozone (O3) concentrations were monitored during the 1997-1999 growing seasons in 32 forest sites of the Carpathian Mountains. At all sites (elevation between 450 and 1320 m) concentrations of O3, nitrogen dioxide (NO2), and sulfur dioxide (SO2) were measured with passive samplers. In addition, in two western Carpathian locations, Vychodna and Gubalówka, ozone was continuously monitored with ultraviolet (UV) absorption monitors. Highest average hourly O3 concentrations in the Vychodna and Guba?ówka sites reached 160 and 200 microg/m3 (82 and 102 ppb), respectively (except for the AOT40 values, ozone concentrations are presented as microg/m3; and at 25 degrees C and 760 mm Hg, 1 microg O3/m3 = 0.51 ppb O3). These sites showed drastically different patterns of diurnal 03 distribution, one with clearly defined peaks in the afternoon and lowest values in the morning, the other with flat patterns during the entire 24-h period. On two elevational transects, no effect of elevation on O3 levels was seen on the first one, while on the other a significant increase of O3 levels with elevation occurred. Concentrations of O3 determined with passive samplers were significantly different between individual monitoring years, monitoring periods, and geographic location of the monitoring sites. Results of passive sampler monitoring showed that high O3 concentrations could be expected in many parts of the Carpathian range, especially in its western part, but also in the eastern and southern ranges. More than four-fold denser network of monitoring sites is required for reliable estimates of O3 distribution in forests over the entire Carpathian range (140 points). Potential phytotoxic effects of O3 on forest trees and understory vegetation are expected on almost the entire territory of the Carpathian Mountains. This assumption is based on estimates of the AOT40 indices for forest trees and natural vegetation. Concentrations of NO2 and SO2 in the entire Carpathian range were typical for this part of Europe and below the expected levels of phytotoxicity.  相似文献   

10.
The purpose of this study was to obtain a better assessment of the Patras, Greece, air quality, in terms of the primary pollutants total suspended particulates (TSPs) and sulfur dioxide (SO2), because limited and short-duration measurements have been conducted in the past. Installation and operation of a mobile air monitoring station at two different locations in the Patras downtown area and one location in the outskirts of the city was undertaken and covered the periods July 1, 1994-January 30, 1995; March 18-August 23, 1995; and April 19-July 27, 1996, respectively. For both pollutants measured at each location, the monthly average concentrations and typical weekly variation of daily averages, as well as the diurnal variations and frequency concentration distributions in each month of the monitoring periods, were calculated and are presented in bar diagrams. The annual and winter period medians and the annual 98th percentile were also calculated and are compared with the limit and guide values provided by the European Economic Community Council Directive 80/779/EEC. In addition, comparison of SO2 values is made with the limit values adopted by the more recent Directive 1999/30/EC. It was found that the TSP and SO2 levels at all locations were very low and were lower than the levels found in Thessaloniki and Athens, Greece. An attempt to explain what had been measured is also undertaken. The data presented are considered essential for future reference and comparison purposes.  相似文献   

11.
Nicotiana tabacum 'Bel W3' is a widely used sensitive bioindicator for ambient ozone, but it is rarely used in tropical countries. Our goal was to determine the suitability of this plant for biomonitoring ozone in the city of S?o Paulo by evaluating the relationships between leaf necroses and ozone under field conditions and measurements of chlorophyll a fluorescence and antioxidants in plants exposed to different concentrations of ozone in closed chambers. While a weak linear relationship between leaf injury and ozone concentrations (R(2)=0.10) was determined in the field, a strong linear relationship was observed in the chamber experiments. Maximum leaf injury was observed in plants submitted to 40 ppb, which coincided with a significant decrease in fluorescence and total ascorbic acid. The relationship between leaf damage observed in the field and ozone was improved when the concentrations were limited to 40 ppb (R(2)=0.28).  相似文献   

12.
A survey of monthly average concentrations of sulfur dioxide (SO2) and hydrogen sulfide (H2S) at rural locations in western Canada (provinces of Alberta, British Columbia, and Saskatchewan) was conducted in 2001-2002, as part of an epidemiological study of the effects of oil and gas industry emissions on the health of cattle. Repeated measurements were obtained at some months and locations. We aimed to develop statistical models of the effect of oil and gas infrastructure on air concentrations. The regulatory authorities supplied the information on location of the different oil and gas facilities during the study period and, for Alberta, provided data on H2S content of wells and flaring volumes. Linear mixed effects models were used to relate observed concentrations to proximity and type of oil and gas infrastructure. Low concentrations were recorded; the monthly geometric mean was 0.1-0.2 ppb for H2S, and 0.3-1.3 ppb for SO2. Substantial variability between repeated measurements was observed. The precision of the measurement method was 0.005 ppb for both contaminants. There were seasonal trends in the concentrations, but the spatial variability was greater. This was explained, in part, by proximity to oil/gas/bitumen wells and (for SO2) gas plants. Wells within 2 km of monitoring stations had the greatest impact on measured concentrations. For H2S, 8% of between-location variability was explained by proximity to industrial sources of emissions; for SO2 this proportion was 18%. In Alberta, proximity to sour gas wells and flares was associated with elevated H2S concentrations; however, the estimate of the effect of sour gas wells in the immediate vicinity of monitoring stations was unstable. Our study was unable to control for all possible sources of the contaminants. However, the results suggest that oil and gas extraction activities contribute to air pollution in rural areas of western Canada.  相似文献   

13.
This study considers the characteristics of carbon monoxide (CO), nitrogen dioxide (NO(2)), ozone (O(3)) and sulfur dioxide (SO(2)) in two major South Korean cities, including the capital city of Seoul, over a time period of 7-8 years. Changes in the annual mean and percentiles of the daily 1-h maximum and other hour-based concentrations varied according to the compound and city type. Seasonal variations varied according to the compound, yet not with the city type. Both Seoul and Taegu exhibited lower O(3) concentrations in July compared to other summer months. There was a high degree of correlation between the daily 1- and 8-h maximum or daily mean concentrations of all compounds in both cities, with an R(2) of 0.66-0.90 at p<0.0001. It was indicated that for CO and O(3), the 8-h standard was more stringent than the 1-h standard, while for NO(2) and SO(2), the 1-h standard was more stringent than the 24-h standard. The correlation coefficients between the daily 1-h maximum and daily mean concentrations decreased as the maximum concentration values of NO(2), O(3 ), and SO(2) increased in the two cities. For all the target compounds, Seoul recorded a substantially higher frequency of days with concentrations above the relevant 1-, 8-, and 24-h standards compared to Taegu.  相似文献   

14.
Ozone concentrations at a rural-remote site in a forested region of north-central West Virginia were monitored during 1988 and 1989, a drought and wet year, respectively. During 1988, the absolute maximum average concentration for a single hour was 156 ppb, while it was only 107 ppb in 1989. Overall, the frequency of high concentrations was greater during 1988; the 120 ppb National Ambient Air Quality Standard was exceeded 17 times. The 7-h period encompassing the highest growing season concentrations for this site over the 2-yr period is 1100- 1759 h EST, rather than the period 0900-1559 h originally used by the National Crop Loss Assessment Network. The 7-h growing season means (0900-1559 h) of 52.6 ppb and 47.1 ppb for 1988 and 1989, respectively, compare well to those reported for the Piedmont/Mountain/Ridge-Valley area, but are higher than those for other surrounding areas. The diurnal ozone patterns, as well as the distribution of concentration ranges and timing of seasonal maxima, suggest that long-range transport of ozone and its precursors probably is an important factor at this site, given its remote and rural character.  相似文献   

15.
Over the past few years, concern has increased in Canada over the health and environmental impacts of elevated concentrations of ground-level ozone. During the summer the most populated regions of Canada frequently record ozone concentrations that exceed the one-hour average maximum acceptable air quality objective of 32 parts per billion (ppb). In 1988 the Canadian Council of Ministers of the Environment agreed to develop a federal/provincial management plan to control nitrogen oxide and volatile organic compound emissions to reduce ozone concentrations in all affected regions of the country. In addition to the proposed interim control measures, the plan recommended that studies be undertaken to acquire the information necessary to develop sound control strategies. This report represents one of those studies and provides a summary of ground-level ozone measurements for eastern Canada for the 1980 to 1991 period with an emphasis on seasonal variations, trends, and occurrences of high concentrations.

Southwestern Ontario experiences the highest maximum hourly ozone concentrations and the greatest frequency of hours greater than the 82 ppb acceptable objective. Urban sites have the highest frequencies of ozone concentration measurements in the < 10 ppb range, while rural and remote sites show peaks in frequency distribution in the 20 to 30 ppb range. Trend analysis of summertime (May to September) average daily maximum ozone concentration showed no consistent pattern for eastern Canadian sites during 1980 to 1991. Sites in Montreal showed statistically insignificant downward trends while sites in Toronto showed small but statistically significant upward trends. These ozone-increasing trends are associated with reductions in nitric oxide concentrations. At all sites there was large year-to-year variability in peak ozone levels and in the frequency of hours with ozone concentrations above the maximum acceptable objective.  相似文献   

16.
The meteorological conditions exert large impacts on ozone concentrations, and may mask the long-term trends in ozone concentrations resulting from precursor emissions. Estimation of long-term trends of ozone concentrations due to the changes in precursor emissions is important for corresponding control strategy. Multiple linear regression (method I), multilayer perceptron (MLP) neural network (method II) and Komogorov-Zurbenko (KZ) filter method plus MLP methodology (method III), are used to estimate the meteorologically adjusted long-term trends of daily maximum ozone concentrations by removing the masking effects of meteorological conditions in this study. The daily maximum ozone concentrations and relative meteorological variables were extracted from six air-monitoring stations in Taipei area from 1994 to 2001. The data collected during 1994–2000 period were used as modeling set and utilized to estimate the meteorologically adjusted trends, and the data of 2001 were used as the validation data. The meteorologically adjusted trends of ozone for these three methods were calculated and compared. The results show that both MLP and KZ filter +MLP models are more suitable than multiple linear regression for estimating the long-term trends of ozone in Taipei, Taiwan. The long-term linear trends of meteorologically adjusted ozone concentrations due to the precursor emissions show an increase trend at all stations, and the percent changes per year range from 1.0% to 2.25% during the modeling period in Taipei area.  相似文献   

17.
This study examined student’s exposure to volatile organic compounds (VOCs) while commuting by bus and motorcycle in Taipei, Taiwan in the winter of 1992. A total of 19 target G5-C10 VOCs on three most frequently used commuting routes were collected on Tenax-GC adsorbent tubes. The VOCs were desorbed by thermal desorption method and analyzed by GCMS. The most abundant VOC exposure experienced by commuters was to toluene. Several alkylated benzenes, such as propyl benzenes, ethyl-methyl-benzenes and trimethyl-benzenes, were relatively abundant on the roads in Taipei. The mean benzene concentration measured in buses was 173 µg/m3 and 379.7 µg/m3 on motorcycles. On the average, the commuters in Taipei experienced about three to eight times higher VOC concentrations than the commuters in Los Angeles, California. Higher VOC concentrations were measured on motorcycles than in buses. The VOC concentrations were not significantly different between morning and afternoon commutes, nor among the three commuting routes. VOC concentrations measured in classrooms at three schools in downtown Taipei did not vary significantly on each sampling day. However, at each school the in-classroom VOC concentrations varied significantly over the six consecutive sampling days. The VOC concentrations measured on the roads were about five times higher than those measured in the school classrooms in the city. Moderate to high correlations were found among most of the measurements of the 19 VOCs. The survey questionnaire indicated that daily commuting time ranged from 45 minutes for elementary school students to 95 minutes for vocational school students. The projected upper-bound cancer risks associated with student’s exposure to benzene ranged from 7.5 x 10-3 to 1.8 x 10-5 during their commutes in Taipei.  相似文献   

18.
Ozone concentrations were measured both inside and outside the Sainsbury Centre for Visual Arts, near a small city in rural eastern England, during a three-week period in summer. The inside concentration was typically 70 ± 10% of the outside concentration during the period of expected maximum outside levels. During the period of observation the maximum outside ozone levels ranged up to 60 ppb, although there have been periods at this location where outside ozone levels have been well in excess of 120 ppb. The relatively high indoor/outdoor ozone ratio is a function of the Centre’s design, its internal geometry, and its ventilation system. Conventional art galleries and museums experience much lower indoor ozone exposure. The measured indoor ozone levels imply deleterious effects on the gallery exhibits and an enhanced ozone exposure may have to be considered in the design of modern galleries and museums.  相似文献   

19.
The natural background in the ozone concentration at rural locations in the United States and western Europe has been estimated by use of several approaches. The approaches utilized include the following: (1) historical trends in ozone concentration measurements, (2) recent ozone measurements at remote sites, (3) use of tracers of air originating in the stratosphere or upper troposphere and (4) results from applications of tropospheric photochemical models. While each of these approaches has its own limitations it appears that the natural background of ozone during the warmer months of the year is in the range of 10 to 20 ppb. Most of the ozone originating in the lower stratosphere or upper troposphere is lost by chemical or physical removal processes as well as undergoing dilution by air in the lower troposphere before reaching ground level rural locations. Lower tropospheric photochemical processes, those below 5 km, are likely to account for most of the ozone measured at rural locations during the warmer months of the year.

A key aspect to improved quantitation of the contributions from lower tropospheric photochemical processes to ozone concentrations continues to be more extensive atmospheric measurements of the distribution of reactive species of nitrogen. The emission densities of anthropogenic sources of NOx are known to be highly variable over populated areas of continents as well as between continental areas and the oceans. The emission densities of biogenic sources of NOx are small, likely to be highly variable, but poorly quantitated. These wide variations indicate the need for use of three dimensional tropospheric photochemical models over large continental regions.

Available results do indicate higher efficiencies for ozone formation at lower NOx concentrations, especially below 1 ppb.  相似文献   

20.
Three modeling approaches, the U.S. Environmental Protection Agency’s (EPA) Community Multiscale Air Quality (CMAQ) zero-out, the Comprehensive Air quality Model with extensions (CAMx) zero-out, and the CAMx probing tools ozone source apportionment tool (OSAT), were used to project the contributions of various source categories to future year design values for summer 8-hr average ozone concentrations at selected U.S. monitors. The CMAQ and CAMx zero-out or brute-force approaches predicted generally similar contributions for most of the source categories, with some small differences. One of the important findings from this study was that both the CMAQ and CAMx zero-out approaches tended to apportion a larger contribution to the “other” category than the OSAT approach. For the OSAT approach, this category is the difference between the total emissions and the sum of the tracked emissions and consists of non-U.S. emissions. For the zero-out approach, it also includes the effects of nonlinearities in the system because the sum of the sensitivities of all sources is not necessarily equal to the sum of their contributions in a nonperturbed environment. The study illustrates the strengths and weaknesses of source apportionment approaches, such as OSAT, and source sensitivity approaches, such as zero-out. The OSAT approach is suitable for studying source contributions, whereas the zero-out approach is suitable for studying response to emission changes. Future year design values of summer 8-hr average ozone concentrations were projected to decrease at all the selected monitors for all the simulations in each city, except at the downtown Los Angeles monitor. Both the CMAQ and CAMx results showed all modeled locations project attainment in 2018 and 2030 to the current National Ambient Air Quality Standards (NAAQS) level of 75 ppb, except the selected Los Angeles monitor in 2018 and the selected San Bernardino monitor in 2018 and 2030.
Implications:This study illustrates the strengths and weaknesses of three modeling approaches, CMAQ zero-out, CAMx zero-out, and OSAT to project contributions of various source categories to future year design values for summer 8-hr average ozone concentrations at selected U.S. monitors. The OSAT approach is suitable for studying source contributions, whereas the zero-out approach is suitable for studying response to emission changes. Future year design values of summer 8-hr average ozone concentrations were projected to decrease, except at the downtown Los Angeles monitor. Comparing projections with the current NAAQS (75 ppb) show attainment everywhere, except two locations in 2018 and one location in 2030.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号