首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 171 毫秒
1.
Surfactant enhanced aquifer remediation (SEAR) had previously been thought to require a capillary barrier below the contaminated zone to prevent the vertical migration of a microemulsion containing solubilized DNAPL. This paper shows the vertical migration of the dense microemulsion is described and predicted by the value of three dimensionless scaling groups. Embedded within these scaling groups are four design parameters. The value of these parameters can be manipulated in order to reduce the amount of vertical migration anticipated for a given remediation design. Plots have been constructed that illustrate the relationship between vertical migration and the value of the scaling groups; such plots can be used to predict vertical migration and to determine appropriate screen intervals of extraction wells to ensure full capture of the contaminants. This predictive capability has been verified in laboratory experiments. Predicted migration of the microemulsion agreed within about 2% of that observed. Development of the scaling groups is presented, remediation design implications are discussed, and laboratory verification is shown. Additional discussion of the laboratory work is given in a companion paper [Kostarelos, K., Pope, G.A., Rouse, B.A., Shook, G.M., 1998. A new concept: the use of neutrally-buoyant microemulsions for DNAPL remediation, J. Contam. Hydro., this edition].  相似文献   

2.
Phase diagrams were used for the formulation of alcohol–surfactant–solvent and to identify the DNAPL (Dense Non Aqueous Phase Liquid) extraction zones. Four potential extraction zones of Mercier DNAPL, a mixture of heavy aliphatics, aromatics and chlorinated hydrocarbons, were identified but only one microemulsion zone showed satisfactory DNAPL recovery in sand columns. More than 90 sand column experiments were performed and demonstrate that: (1) neither surfactant in water, alcohol–surfactant solutions, nor pure solvent can effectively recover Mercier DNAPL and that only alcohol–surfactant–solvent solutions are efficient; (2) adding salts to alcohol–surfactant or to alcohol–surfactant–solvent solutions does not have a beneficial effect on DNAPL recovery; (3) washing solution formulations are site specific and must be modified if the surface properties of the solids (mineralogy) change locally, or if the interfacial behavior of liquids (type of oil) changes; (4) high solvent concentrations in washing solutions increase DNAPL extraction but also increase their cost and decrease their density dramatically; (5) maximum DNAPL recovery is observed with alcohol–surfactant–solvent formulations which correspond to the maximum solubilization in Zone C of the phase diagram; (6) replacing part of surfactant SAS by the alcohol n-butanol increases washing solution efficiency and decreases the density and the cost of solutions; (7) replacing part of n-butanol by the nonionic surfactant HOES decreases DNAPL recovery and increases the cost of solutions; (8) toluene is a better solvent than D-limonene because it increases DNAPL recovery and decreases the cost of solutions; (9) optimal alcohol–surfactant–solvent solutions contain a mixture of solvents in a mass ratio of toluene to D-limonene of one or two. Injection of 1.5 pore volumes of the optimal washing solution of n-butanol–SAS–toluene–D-limonene in water can recover up to 95% of Mercier DNAPL in sand columns. In the first pore volume of the washing solution recovered in the sand column effluent, the DNAPL is in a water-in-oil microemulsion lighter than the excess aqueous phase (Winsor Type II system), which indicates that part of the DNAPL was mobilized. In the next pore volumes, DNAPL is dissolved in a oil-in-water microemulsion phase and is mobilized in an excess oil phase lighter than the microemulsion (Winsor Type I system). The main drawback of this oil extraction process is the high concentration of ingredients necessary for DNAPL dissolution, which makes the process expensive. Because mobilization of oil seems to occur at the washing solution front, an injection strategy must be developed if there is no impermeable limit at the aquifer base. DNAPL recovery in the field could be less than observed in sand columns because of a smaller sweep efficiency related to field sand heterogeneities. The role of each component in the extraction processes in sand column as well as the Winsor system type have to be better defined for modeling purposes. Injection strategies must be developed to recover ingredients of the washing solution that can remain in the soil at the end of the washing process. ©1997 Elsevier Science B.V.  相似文献   

3.
A framework is developed for simultaneous, optimal design of groundwater contaminant source removal and plume remediation strategies. The framework allows for varying degrees of effort and cost to be dedicated to source removal versus plume remediation. We have accounted for the presence of physical heterogeneity in the DNAPL source, since source heterogeneity controls mass release into the plume and the efficiency of source removal efforts. We considered high and low estimates of capital and operating costs for chemical flushing removal of the source, since these are expected to vary form site to site. Using the lower chemical flushing cost estimates, it is found that the optimal allocation of funds to source removal or plume remediation is sensitive to the degree of heterogeneity in the source. When the time elapsed between the source release and the implementation of remediation was varied, it was found that, except for the longest elapsed time (50,000 days), a combination of partial source removal and plume remediation was most efficient. When first-order, dissolved contaminant degradation was allowed, source removal was found to be unnecessary for the cases where the degradation rate exceeded intermediate values of the first-order rate constant. Finally, it was found that source removal became more necessary as the degree of aquifer heterogeneity increased.  相似文献   

4.
Analytical solutions, describing the time-dependent DNAPL source-zone mass and contaminant discharge rate, derived previously in Part I [Falta, R.W., Rao, P.S., Basu, N., this issue. Assessing the impacts of partial mass depletion in DNAPL source zones: I. Analytical modeling of source strength functions and plume response. J. Contam. Hydrol.] are used as a flux-boundary condition in a semi-analytical contaminant transport model. These analytical solutions assume a power relationship between the flow-averaged source concentration, and the source DNAPL mass; the empirical exponent (gamma) is a function of the flow field heterogeneity, DNAPL architecture, and the correlation between them. The DNAPL source strength terms can account for partial source remediation, either at time zero, or at some later time after the DNAPL release. The transport model considers advection, retardation, three-dimensional dispersion, and sequential first-order decay/production of several species. A separate solution is used to compute the time-dependent mass of each contaminant in the plume. A series of examples using different values of gamma shows how the benefits of partial DNAPL source remediation can vary with site conditions. In general, when gamma>1, relatively large short-term reductions in the plume concentrations and mass occur, but the source longevity is not strongly affected. Conversely, when gamma<1, the short-term reductions in the plume concentrations and mass are smaller, but the source longevity can be greatly reduced. In either case, the source remediation effort is much more effective if it is undertaken at an early time, before much contaminant mass has entered the plume. If the remediation effort is significantly delayed, the leading parts of the plume are not affected by the source remediation, and additional control or remediation of the plume itself is required.  相似文献   

5.
Modeling field-scale cosolvent flooding for DNAPL source zone remediation   总被引:2,自引:1,他引:1  
A three-dimensional, compositional, multiphase flow simulator was used to model a field-scale test of DNAPL removal by cosolvent flooding. The DNAPL at this site was tetrachloroethylene (PCE), and the flooding solution was an ethanol/water mixture, with up to 95% ethanol. The numerical model, UTCHEM accounts for the equilibrium phase behavior and multiphase flow of a ternary ethanol-PCE-water system. Simulations of enhanced cosolvent flooding using a kinetic interphase mass transfer approach show that when a very high concentration of alcohol is injected, the DNAPL/water/alcohol mixture forms a single phase and local mass transfer limitations become irrelevant. The field simulations were carried out in three steps. At the first level, a simple uncalibrated layered model is developed. This model is capable of roughly reproducing the production well concentrations of alcohol, but not of PCE. A more refined (but uncalibrated) permeability model is able to accurately simulate the breakthrough concentrations of injected alcohol from the production wells, but is unable to accurately predict the PCE removal. The final model uses a calibration of the initial PCE distribution to get good matches with the PCE effluent curves from the extraction wells. It is evident that the effectiveness of DNAPL source zone remediation is mainly affected by characteristics of the spatial heterogeneity of porous media and the variable (and unknown) DNAPL distribution. The inherent uncertainty in the DNAPL distribution at real field sites means that some form of calibration of the initial contaminant distribution will almost always be required to match contaminant effluent breakthrough curves.  相似文献   

6.
表面活性剂强化抽出处理含水层中DNAPL污染物的去除特征   总被引:1,自引:0,他引:1  
为明确表面活性剂强化抽出处理含水层中DNAPL污染物过程中表面活性剂的增强修复效果,及DNAPL自身理化性质和介质孔径的影响,利用数码图像分析技术对1,2-二氯乙烷和四氯乙烯2种DNAPL在石英砂填充的二维砂箱中的抽取迁移过程进行了实验模拟研究,并对抽出水样中DNAPL的浓度进行了测试分析。结果表明,实验条件下加入低浓度(0.18%)的十二烷基苯磺酸钠(SDBS)大幅提高了对弱透水层截留的2种DNAPL聚集体的抽出处理效率。1,2-二氯乙烷在该表面活性剂溶液中的表观溶解度远高于四氯乙烯,因此其短时间内的绝对去除率更高。SDBS强化抽出处理DNAPL的作用机理以增溶作用为主,而其增流作用使DNAPL迁移流动后分布面积增大,增加了与表面活性剂溶液接触的面积,对增溶作用起到促进效果。细粒介质中DNAPL迁移后的最大分布面积较大,因此体系中DNAPL的溶解速率较高。在DNAPL聚集体质量与水力梯度固定的条件下,油水界面张力越低,DNAPL的密度越大,DNAPL垂向迁移的风险就越大。本研究为修复工程中如何依据DNAPL种类与场地多孔介质的情况选择表面活性剂提供了参考。  相似文献   

7.
就SEAR技术修复土壤及地下水中NAPL污染的原理及发展现状进行了综述.SEAR技术可以快速有效地去除土壤和地下水中的NAPL污染源,适于多种污染物.该技术通过增溶和增流2种途径提高NAPL污染物的去除率.表面活性剂的选择和微乳液体系的调配是SEAR技术实施的关键环节.将SEAR技术用于高浓度NAPL污染源的治理,并与生物修复和自然降解相结合,是经济高效的治理方案.  相似文献   

8.
A two-dimensional (2D) laboratory model was used to study effects of gravity on areal recovery of a representative dense non-aqueous phase liquid (DNAPL) contaminant by an alcohol pre-flood and co-solvent flood in dipping aquifers. Recent studies have demonstrated that injection of alcohol and co-solvent solutions can be used to reduce in-situ the density of DNAPL globules and displace the contaminant from the source zone. However, contact with aqueous alcohol reduces interfacial tension and causes DNAPL swelling, thus facilitating risk of uncontrolled downward DNAPL migration. The 2D laboratory model was operated with constant background gradient flow and a DNAPL spill was simulated using tetrachloroethene (PCE). The spill was dispersed to a trapped, immobile PCE saturation by a water flood. Areal PCE recovery was studied using a double-triangle well pattern to simulate a remediation scheme consisting of an alcohol pre-flood using aqueous isobutanol ( approximately 10% vol.) followed by a co-solvent flood using a solution of ethylene glycol (65%) and 1-propanol (35%). Experiments were conducted with the 2D model oriented in the horizontal plane and compared to experiments at the 15 degrees and 30 degrees dip-angle orientations. Injection was applied either in the downward or upward direction of flow. Experimental results were compared to theoretical predictions for flood front stability and used to evaluate effects of gravity on areal PCE recovery. Sensitivity experiments were performed to evaluate effects of the alcohol pre-flood on PCE areal recovery. For experiments conducted with the alcohol pre-flood and the 2D model oriented in the horizontal plane, results indicate that 89-93% of source zone PCE was recovered. With injection oriented downward, results indicate that areal PCE recovery was 70-77% for a 15 degrees dip angle and 57-59% for a 30 degrees dip angle. With injection oriented upward, results indicate that areal PCE recovery was 57-60% at the 30 degrees dip angle, which was similar to PCE recovery for injection in the downward flow direction. Lower areal PCE recovery at greater dip angles in either direction of flow was attributed to DNAPL swelling and migration, flood front instabilities and bypassing of the displaced fluid past the extraction wells during the alcohol pre-flood. Additional results demonstrate that the use of an alcohol pre-flood can be beneficial in improving DNAPL recovery in the horizontal orientation, but pre-flooding may reduce areal recovery efficiency in dip-angle orientations. This study also demonstrates the use of theoretical perturbation (fingering) analysis in predicting NAPL recovery efficiency for flooding processes in remediating aquifers with dip angles.  相似文献   

9.
This study provides a coupled simulation–optimization approach for optimal design of petroleum-contaminated groundwater remediation under uncertainty. Compared to the previous approaches, it has the advantages of: (1) addressing the stochasticity of the modeling parameters in simulating the flow and transport of NAPLs in groundwater, (2) providing a direct and response-rapid bridge between remediation strategies (pumping rates) and remediation performance (contaminant concentrations) through the created proxy models, (3) alleviating the computational cost in searching for optimal solutions, and (4) giving confidence levels for the obtained optimal remediation strategies. The approach is applied to a practical site in Canada for demonstrating its performance. The results show that mitigating the effects of uncertainty on optimal remediation strategies (through enhancing the confidence level) would lead to the rise of remediation cost due to the increase in the total pumping rate.  相似文献   

10.
Analytical solutions are developed for approximating the time-dependent contaminant discharge from DNAPL source zones undergoing dissolution and other decay processes. The source functions assume a power relationship between source mass and chemical discharge and can consider partial DNAPL source remediation (depletion) at any time after the initial DNAPL release. The source functions are used as a time-dependent boundary condition in an idealized chemical transport model to develop leading order approximations of the plume response to DNAPL source removal. The results suggest that partial DNAPL remediation does not tend to have a dramatic impact on the maximum extent of the plume if very low concentration values are used to define the plume boundaries. However, the solutions show that partial DNAPL removal from the source zone is likely to lead to large reductions in plume concentrations and mass, and it reduces the longevity of the plume. When the mass discharge from the source zone is linearly related to the DNAPL mass, it is shown that partial DNAPL depletion leads to linearly proportional reductions in the plume mass and concentrations.  相似文献   

11.

In this study, fate and contaminant transport model-driven human health risk indexes were calculated due to the presence of dense non-aqueous phase liquids (DNAPLs) in the subsurface environment of air force base area in Florida, USA. Source concentration data of DNAPLs was used for the calculation of transport model-driven health risk indexes for the children and adult sub-population via direct oral ingestion and skin dermal contact exposure scenario using 10,000 Monte Carlo type simulations. The highest variation in the probability distribution of transformed DNAPL compound (cis-dichloroethene (cis-DCE) > vinyl chloride (VC)) was observed as compared to parent DNAPL (tetrachloroethene (PCE)) based on the 50-year simulation timespan. Transformed DNAPL compounds (VC, cis-DCE) posed the highest risk to human health for a longer duration (up to 15 years) in comparison to parent DNAPL (PCE), as non-carcinogenic hazard quotient varied from 400 to 1100. Carcinogenic health risks were observed as 3-order of magnitude higher than safe limit (HQSafe < 10−6) from 2nd to 5th year timespan and fall in the high-risk zone, indicating the need for a remediation plan for a contaminated site. Variance attribution analysis revealed that concentration, body weight, and exposure duration (contribution percentage – 70 to 95%) were the most important parameters, highlighting the impact of dispersivity and exposure model in the estimation of risk indexes. This approach can help decision-makers when a contaminated site with partial data on hydrogeological properties and with higher uncertainty in model parameters is to be assessed for the formulation of remediation measures.

  相似文献   

12.
Understanding the process of mass transfer from source zones of aquifers contaminated with organic chemicals in the form of dense non-aqueous phase liquids (DNAPL) is of importance in site management and remediation. A series of intermediate-scale tank experiments was conducted to examine the influence of aquifer heterogeneity on DNAPL mass transfer contributing to dissolved mass emission from source zone into groundwater under natural flow before and after remediation. A Tetrachloroethylene (PCE) spill was performed into six source zone models of increasing heterogeneity, and both the spatial distribution of the dissolution behavior and the net effluent mass flux were examined. Experimentally created initial PCE entrapment architecture resulting from the PCE migration was largely influenced by the coarser sand lenses and the PCE occupied between 30 and 60% of the model aquifer depth. The presence of DNAPL had no apparent effect on the bulk hydraulic conductivity of the porous media. Up to 71% of PCE mass in each of the tested source zone was removed during a series of surfactant flushes, with associated induced PCE mobilization responsible for increasing vertical DNAPL distributions. Effluent mass flux due to water dissolution was also found to increase progressively due to the increase in NAPL-water contact area even though the PCE mass was reduced. Doubling of local groundwater flow velocities showed negligible rate-limited effects at the scale of these experiments. Thus, mass transfer behavior was directly controlled by the morphology of DNAPL within each source zone. Effluent mass flux values were normalized by the up-gradient DNAPL distributions. For the suite of aquifer heterogeneities and all remedial stages, normalized flux values fell within a narrow band with mean of 0.39 and showed insensitivity to average source zone saturations.  相似文献   

13.
When steam is injected into soil containing a dense volatile non-aqueous phase liquid contaminant, the DNAPL vaporized within the heated soil region condenses and accumulates ahead of the steam condensation front. If enough DNAPL accumulates, gravitational forces can overcome trapping forces allowing the liquid contaminant to flow downward. By injecting air with steam, a portion of the DNAPL vapor remains suspended in equilibrium with the air, decreasing liquid contaminant accumulation ahead of the steam condensation front, and thus reducing the possibility of downward migration. In a previous work, a theoretical model was developed to predict the optimum injection ratio of air to steam that would eliminate accumulation of DNAPL ahead of the temperature front and thus minimize the potential for downward migration. In this work, the theoretical model is summarized, and an experiment is presented in order to evaluate the optimum injection ratio prediction. In the experiment, a two-dimensional water saturated sand pack is contaminated with a known mass of TCE (DNAPL). The system is then remediated by co-injecting air and steam at the predicted optimum injection ratio, calculated based on the average contaminant soil concentration in the sand pack. Results for the co-injection of air and steam are compared to results for the injection of pure steam or pure air. Injection at the predicted optimum injection ratio for a volumetric average NAPL saturation, reduced accumulation of the contaminant ahead of the condensation front by over 90%, as compared to steam injection alone. This indicates that the optimum injection ratio prediction is a valuable tool for limiting the spreading of DNAPL during steam-enhanced extraction. Injection at the optimum injection ratio resulted in earlier recovery of contaminant than for steam injection alone. Co-injection of steam and air is also shown to result in much higher recovery rates than air injection alone.  相似文献   

14.
We have conducted well-controlled DNAPL remediation experiments within a 2-D, glass-walled, sand-filled chamber using surfactants (Aerosol MA and Tween 80) to increase solubility and an oxidant (permanganate) to chemically degrade the DNAPL. Initial conditions for each remediation experiment were created by injecting DNAPL as a point source at the top of the chamber and allowing the DNAPL to migrate downward through a water-filled, heterogeneous, sand-pack designed to be evocative of a fluvial depositional environment. This migration process resulted in the DNAPL residing as a series of descending pools. Lateral advection across the chamber was used to introduce the remedial fluids. Photographs and digital image analysis illustrate interactions between the introduced fluids and the DNAPL. In the surfactant experiments, we found that DNAPL configured in a series of pools was easily mobilized. Extreme reductions in DNAPL/water interfacial tension occurred when using the Aerosol MA surfactant, resulting in mobilization into low permeability regions and thus confounding the remediation process. More modest reductions in interfacial tension occurred when using the Tween 80 surfactant resulting in modest mobilization. In this experiment, capillary forces remained sufficient to exclude DNAPL migration into low permeability regions allowing the excellent solubilizing properties of the surfactant to recover almost 90% of the DNAPL within 8.6 pore volumes. Injection of a potassium permanganate solution resulted in precipitation of MnO2, a reaction product, creating a low-permeability rind surrounding the DNAPL pools. Formation of this rind hindered contact between the permanganate and the DNAPL, limiting the effectiveness of the remediation. From these experiments, we see the value of performing visualization experiments to evaluate the performance of proposed techniques for DNAPL remediation.  相似文献   

15.
While the capability of nanoscale zero-valent iron (NZVI) to dechlorinate organic compounds in aqueous solutions has been demonstrated, the ability of NZVI to remove dense non-aqueous phase liquid (DNAPL) from source zones under flow-through conditions similar to a field scale application has not yet been thoroughly investigated. To gain insight on simultaneous DNAPL dissolution and NZVI-mediated dechlorination reactions after direct placement of NZVI into a DNAPL source zone, a combined experimental and modeling study was performed. First, a DNAPL tetrachloroethene (PCE) source zone with emplaced NZVI was built inside a small custom-made flow cell and the effluent PCE and dechlorination byproducts were monitored over time. Second, a model for rate-limited DNAPL dissolution and NZVI-mediated dechlorination of PCE to its three main reaction byproducts with a possibility for partitioning of these byproducts back into the DNAPL was formulated. The coupled processes occurring in the flow cell were simulated and analyzed using a detailed three-dimensional numerical model. It was found that subsurface emplacement of NZVI did not markedly accelerate DNAPL dissolution or the DNAPL mass-depletion rate, when NZVI at a particle concentration of 10g/L was directly emplaced in the DNAPL source zone. To react with NZVI the DNAPL PCE must first dissolve into the groundwater and the rate of dissolution controls the longevity of the DNAPL source. The modeling study further indicated that faster reacting particles would decrease aqueous contaminant concentrations but there is a limit to how much the mass removal rate can be increased by increasing the dechlorination reaction rate. To ensure reduction of aqueous contaminant concentrations, remediation of DNAPL contaminants with NZVI should include emplacement in a capture zone down-gradient of the DNAPL source.  相似文献   

16.
Two-dimensional chamber studies were conducted to determine qualitative and quantitative performance of cosolvents targeted at pooled dense non-aqueous phase liquid (DNAPL) (perchlorethylene, PCE) residing above a fine-grain capillary barrier. Downward mobilization of DNAPL, up gradient along an overriding cosolvent front, was observed. This produced significant pooling above a fine-grain layer that in some cases lead to entry into the capillary barrier beneath. Entry pressure calculations using physical and hydrogeologic parameters provided an excellent prediction of breakthrough of DNAPL into the capillary barrier. Calculations predict approximately 0.5 m of DNAPL would be necessary to enter a Beit Netofa clay, under extreme cosolvent flooding conditions (100% ethanol). Gradient injection of cosolvent did not appear to provide any benefit suggesting a rapid decrease in interfacial tension (IFT) compared to the rate of DNAPL solubilization. Use of a partitioning alcohol (tertiary butyl alcohol, TBA) resulted in DNAPL swelling and reduced entry into the capillary barrier. However, the trapping of flushing solution, containing PCE, could potentially lead to longer remediation times.  相似文献   

17.
We describe a three-dimensional, multicomponent, multiphase compositional finite-difference simulator for application to the analysis of contaminant transport and surfactant enhanced aquifer remediation (SEAR) of nonaqueous-phase liquid (NAPL) pollutants. Mixtures of surfactant, water and NAPL can form many types of micellar and microemulsion phases with a complex and important dependence on many variables of which the dilute aqueous solution typically assumed in SEAR models is just one example. The phase behavior model is central to our approach and allows for the full range of the commonly observed micellar and microemulsion behavior pertinent to SEAR. The other surfactant related properties such as adsorption, interfacial tension, capillary pressure, capillary number and microemulsion viscosity are all dependent on an accurate phase behavior model. This has proven to be a highly successful approach for surfactant enhanced oil recovery modeling, so it was adapted to SEAR modeling. However, there are many significant differences between petroleum and environmental applications of surfactants, so many new features have been added to model contaminant transport and remediation and these are described and illustrated for the first time here.  相似文献   

18.
Changes in contaminant fluxes resulting from aggressive remediation of dense nonaqueous phase liquid (DNAPL) source zone were investigated at two sites, one at Hill Air Force Base (AFB), Utah, and the other at Ft. Lewis Military Reservation, Washington. Passive Flux Meters (PFM) and a variation of the Integral Pumping Test (IPT) were used to measure fluxes in ten wells installed along a transect down-gradient of the trichloroethylene (TCE) source zone, and perpendicular to the mean groundwater flow direction. At both sites, groundwater and contaminant fluxes were measured before and after the source-zone treatment. The measured contaminant fluxes (J; ML(-2)T(-1)) were integrated across the well transect to estimate contaminant mass discharge (M(D); MT(-1)) from the source zone. Estimated M(D) before source treatment, based on both PFM and IPT methods, were approximately 76 g/day for TCE at the Hill AFB site; and approximately 640 g/day for TCE, and approximately 206 g/day for cis-dichloroethylene (DCE) at the Ft. Lewis site. TCE flux measurements made 1 year after source treatment at the Hill AFB site decreased to approximately 5 g/day. On the other hand, increased fluxes of DCE, a degradation byproduct of TCE, in tests subsequent to remediation at the Hill AFB site suggest enhanced microbial degradation after surfactant flooding. At the Ft. Lewis site, TCE mass discharge rates subsequent to remediation decreased to approximately 3 g/day for TCE and approximately 3 g/day for DCE approximately 1.8 years after remediation. At both field sites, PFM and IPT approaches provided comparable results for contaminant mass discharge rates, and show significant reductions (>90%) in TCE mass discharge as a result of DNAPL mass depletion from the source zone.  相似文献   

19.
Nanoscale zero-valent iron (nZVI) has received considerable attention as a potential in situ remediation technology for treating chlorinated solvent source zones. Experimental and mathematical modeling studies were conducted to investigate the performance of nZVI in the transformation of tetrachloroethene (PCE) entrapped as a dense nonaqueous phase liquid (DNAPL). Injection of a 60 g/L suspension of nZVI into a column containing 20-30 mesh Ottawa sand and PCE-DNAPL at a residual saturation of 5.5% resulted in a uniform distribution of nZVI and minimal displacement of PCE. Subsequent flushing with 267 pore volumes of water containing 3mM CaCl(2) at a Darcy velocity of 0.75 m/day resulted in steady-state effluent concentrations of PCE near the solubility limit (ca. 200mg/L) and production of dissolved-phase ethene (10-30 mg/L). Over the duration of the experiment, approximately 30% of the initial PCE-DNAPL mass reacted to form ethene, 50% was eluted as dissolved-phase PCE, and 20% remained in the column as PCE-DNAPL. To further explore the implications of the nZVI column results, a multiphase transport model was developed that incorporated rate-limited PCE-DNAPL dissolution and reactions with nZVI. Using a fitted pseudo first-order transformation rate coefficient of 1.421/h, the model accurately captured observed trends in effluent concentrations of PCE and ethene and overall mass balance. A model sensitivity study reveals a strong dependence of treatment effectiveness on system characteristics. The sensitivity analysis suggests that an increase in the extent of PCE transformation is facilitated by decreasing flow rate, emplacement of nZVI down-gradient of the DNAPL source zone, and decreasing length of the DNAPL source zone. These findings indicate that, although emplacement of high concentrations of nZVI within a PCE-DNAPL source zone can result in substantial transformation of the parent compound, careful attention to design parameters (e.g. flow rate, location and amount nZVI delivered) will be required to achieve complete conversion to benign reaction products.  相似文献   

20.
A particular problem with the release of dense nonaqueous phase liquids (DNAPLs) into the environment is identifying where the DNAPL is and if it is still moving. This question is particularly important at sites where thousands of cubic meters of DNAPLs were disposed of. To date, results from laboratory models have not been scaled to predict analogous migration at the larger length and time scales appropriate for sites where large volumes of DNAPLs were released. Modified inspectional analysis is a technique for developing scaling relationships through nondimensionalizing the governing equations. It was applied in this study to scale observations of DNAPL migration in a laboratory model to four hypothetical scenarios in the field where large volumes of DNAPL were released. One scenario was compared to a large DNAPL spill site. The length and time scales of DNAPL movement predicted from our analysis are consistent with those predicted from a numerical model of this site. To our knowledge, this is the first application of modified inspectional analysis for release of DNAPLs in a laboratory model. This methodology may prove useful for scaling results from other laboratory investigations of DNAPL migration to field-scale systems.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号