首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
A number of methods are used to assess exposure to high-molecular weight allergens. In the occupational setting, airborne dust is often collected on filters using pumps, the filters are eluted and allergen content in the eluate analysed using immunoassays. Collecting inhalable dust using person-carried pumps may be considered the gold standard. Other allergen sampling methods are available. Recently, a method that collects nasally inhaled dust on adhesive surfaces within nasal samplers has been developed. Allergen content can be analysed in eluates using sensitive enzyme immunoassays, or allergen-bearing particles can be immunostained using antibodies, and studied under the microscope. Settling airborne dust can be collected in petri dishes, a cheap and simple method that has been utilised in large-scale exposure studies. Collection of reservoir dust from surfaces using vacuum cleaners with a dust collector is commonly used to measure pet or mite allergens in homes. The sampling methods differ in properties and relevance to personal allergen exposure. Since methods for all steps from sampling to analysis differ between laboratories, determining occupational exposure limits for protein allergens is today unfeasible. A general standardisation of methods is needed.  相似文献   

2.
Well-validated methods for measuring airborne occupational allergens are essential for effective control and reduction of allergen exposures. For wheat flour allergens, specific immunoassays are available, but there is a need for optimisation and standardization of sample processing procedures. Wheat flour allergen elution and storage were studied using airborne dust samples collected in bakeries with a new parallel sampler. Forty-eight series of 9 parallel filters were subjected to extraction procedures varying in elution medium, shaking method, extraction vial, and centrifugation speed. Wheat allergens were measured with enzyme immunoassays, and the effect of various procedures evaluated by mixed regression analyses. The stability of the eluted allergens was assessed after storage for 20 days and 4 months at -20 degrees C, in the presence or absence of casein in the medium. Only the type of elution medium had significant effects on allergen recovery: addition of Tween-20 resulted in 3- to 100-fold increased levels, an effect that was most pronounced at low concentrations. Allergen levels in extracts were stable for at least 4 months at -20 degrees C, irrespective of the presence of casein in the medium. Addition of Tween-20 to the elution medium is essential for optimal extraction of wheat allergen. The recommended procedure further includes the use of conventional polystyrene tubes, simple shaking methods, and centrifugation after extraction. Wheat dust extracts in PBS-Tween can be stored frozen for at least 4 months, and addition of a stabilising protein is not required.  相似文献   

3.
Immunoassay methods are generally used for measuring of allergenic substances. However, they need special facilities, skilled handling, and time-consuming procedure. In this work, a fiber-optic immunoassay system which could measure allergen by fluorescent intensities of immune complexes formed by allergens and fluorescently labeled antibodies was established. Immune complexes absorbed on the optical fiber probe surface, and excitation light was injected into the probe, then evanescent field is created in the proximity of the probe. The fluorophores were excited by the evanescent light, and fluorescence was detected by a photo diode. The target allergen detected by our system was Der f1 derived from Dermatophagoides farinae that is one of the house dust mite and major source of inhaled allergens. The fluorophore used labeling on detecting antibody was cyanine 5. The system enabled to detect and quantitatively determine of Der f1. The measurement range was from 0.24 to 250?ng/ml, and the result competes with ELISA. The measurement time was 16?min/sample. The immunoassay system was applied to measurement of Der f1 from actual dust samples. Calculated values of Der f1 showed good correlations between the fiber-optic fluoroimmunoassay and ELISA.  相似文献   

4.
Fungal alpha-amylase is a flour supplement which is added to improve the quality of bakery products. Various studies have shown that exposure to this enzyme is an important risk factor for the development of bakers' allergy and this allergy is reported to be one of the most frequent causes of occupational asthma. A rapid assay was developed to monitor exposure to occupational allergens directly at the workplace. The sensitivity of the developed assay is 0.32 ng amylase mL(-1) in a buffer system with the commercially available alpha-amylase preparation Fungamyl 1600S as the standard. Initial validation tests (n = 33) were performed with airborne and settled dust from an industrial bakery. The new lateral flow immunoassay detected amylase in 22 of the 26 samples regarded as positive in an enzyme immunoassay, and was negative for all seven enzyme immunoassay-negative samples, while the four lateral flow immunoassay-negative/enzyme immunoassay-positive samples all had levels below 2 ng mL(-1). The sensitivity of 2 ng mL(-1) of the amylase lateral flow immunoassay is sufficient for first screening purposes and, therefore, this simple and rapid assay may allow direct on-site demonstration of work-related hazards of bio-allergen exposure. This would be particularly useful in occupational hygiene practice, especially in traditional or small-scale bakeries which lack the technological skills for testing the exposure to respiratory allergens.  相似文献   

5.
Pet allergens and mold growth related to damp are common phenomena in day care centers in Sweden but exposure measurements of these factors are lacking. The aim of this study was to investigate the relationship between building construction and indoor environment quality in Swedish day care centers and the potential for exposure to fungi (analyzed by quantitative PCR) and animal allergens (analyzed by ELISA). Measurements were performed in 21 day care centers (103 rooms) from one municipality in Sweden, which were identified as constructions at risk of dampness (85% of the buildings) and with visible damage and mold growth (54% of the buildings). Dust samples were collected using cotton swab and Petri dishes. Total fungal DNA was detected in 99% and 100%, Aspergillus/Penicillium DNA in 54% and 68%, and Stachybotrys chartarum DNA in 4% and 9% of the investigated rooms in cotton swab and Petri dish samples, respectively. The total fungal DNA levels (Geometric Mean, GM) were 4.2 × 10(6) cell equivalents per m(2) and 2.9 × 10(5) cell equivalents per m(2) per day in the swab and Petri dish samples, respectively. The concentrations (GM) of cat (Fel d1), dog (Can f1), and horse (Equ cx) allergens were 9.4, 7.2 ng m(-2) day(-1), and 5.0 unit per m(2) per day, respectively. Total fungal DNA levels were higher in risk construction buildings (p = 0.01), in rooms with linoleum flooring material (p = 0.003), and in buildings with rotating heat exchangers (p = 0.02). There were associations between total fungal DNA levels and cat (p = 0.02), dog (p < 0.001), and horse (p = 0.001) allergens. In conclusion, risk constructions, damp constructions, mould growth, fungal DNA, and animal allergens were common exposure factors in Swedish day care centers. Building constructions that represent a high risk for internal dampness should be avoided in the future, and measures to reduce allergen levels should be considered to protect pet-allergic children from asthmatic problems.  相似文献   

6.
The present study aimed to assess whether urinary germanium concentration can be used as a biomarker of inhalation exposure to airborne dust from metallic germanium (Ge) or GeO2 in the occupational setting. A novel hydride generation-based method coupled with fow-injection graphite furnace atomic absorption spectrometry (HG/FI-GFAAS) was developed for the determination of urinary germanium. It was found that urinary germanium concentration could be reliably determined by a standard additions method after thorough digestion of the urine and careful pH adjustment of the digest. The limit of detection (LOD) in urine for the HG/FI-GFAAS method was 0.25 microg Ge L(-1). In Belgian control male subjects, the urinary germanium concentration was below this LOD. In 75 workers currently exposed to inorganic germanium compounds, respirable and inhalable concentrations of germanium in the aerosols were measured on Monday and Friday at the job sites using personal air samplers. Spot-urine samples were collected on the same days before and after the work shift. The germanium concentrations of respirable dust correlated very well with those of inhalable dust and represented 20% of the inhalable fraction. Workers exposed to metallic Ge dust were on average ten times less exposed to germanium than those whose exposure involved GeO2 (3.4 versus 33.8 microg Ge m(-3)). This difference was reflected in the urinary germanium concentrations (3.4 versus 23.4 microg Ge g(-1) creatinine). Regression analysis showed that the concentration of germanium in the inhalable fraction explained 42% of the post-shift urinary germanium concentration either on Monday or on Friday, whereas in a subgroup of 52 workers mainly exposed to metallic germanium dust 57% (r = 0.76) of the Monday post-shift urinary germanium was explained. Urinary elimination kinetics were studied in seven workers exposed to airborne dust of either metallic Ge or GeO2. The urinary elimination rate of germanium was characterised by half-times ranging from 8.2 to 18.1 h (on average 12 h 46 min). The present study did not allow discrimination between the germanium species to which the workers were exposed, but it showed fast urinary elimination kinetics for inhalation exposure to dust of metallic Ge and GeO2. It pointed out that urine samples taken at the end of the work shift can be used for biological monitoring of inorganic germanium exposure in the occupational setting.  相似文献   

7.
Studies on personal dust and endotoxin concentrations among animal farmers have been either small or limited to a few sectors in their investigations. The present study aimed to provide comparable information on the levels and variability of exposure to personal dust and endotoxin in different types of animal farmers. 507 personal inhalable dust samples were collected from 327 farmers employed in 54 pig, 26 dairy, 3 poultry, and 3 mink farms in Denmark. Measurements in pig and dairy farmers were full-shift and performed during summer and winter, while poultry and mink farmers were monitored during 4 well-defined production stages. The collected samples were measured for dust gravimetrically and analyzed for endotoxin by the Limulus amebocyte lysate assay. Simple statistics and random-effect analysis were used to describe the levels and the variability in measured dust and endotoxin exposure concentrations. Measured inhalable dust levels had an overall geometric mean of 2.5 mg m(-3) (range 相似文献   

8.
The aim of this study was to estimate mite antigen exposure in farming environments by passive sampling of airborne dust. Antigen concentrations were measured with enzyme immunoassays specific for three storage mites (SM): Acarus siro, Lepidoglyphus destructor, Tyrophagus putrescentiae and the house dust mite (HDM) Dermatophagoides pteronyssinus. Dust samples were collected with electrostatic dust fall collectors (EDCs) in three different areas of cattle farms. EDCs were placed in cow stables (working area), in changing rooms (transit area) and in different rooms of farmer dwellings (living area). Mite concentrations in the living area of farm homes were compared to those of urban homes. In dust samples from stables, antigens of all four mite species could be detected. The highest exposure level was to L. destructor (median 56.7 μg/m(2)), the lowest to A. siro (median 14.4 μg/m(2)). Mite concentrations of different species showed no correlation within the cow stables. In comparison to stables, the median mite concentrations in farm homes were significantly lower, ranging from below the detection limit to 1.5 μg/m(2). Antigens of SM were predominantly found in changing rooms and kitchens, and HDM antigens were mainly detected in bedrooms. Antigens of all mites were measured the least often in living rooms. T. putrescentiae was the most prevalent mite in all room types, and the exposure levels correlated strongly between different rooms. The number of SM positive samples in farm homes was considerably higher than in urban homes, while the percentage of HDM positive samples did not differ significantly.  相似文献   

9.
10.
Symptoms such as shortness of breath and cough have been noted in woodworking facilities even where wood dust itself is well-controlled. Suspicion has fallen on other possible contaminants in the workplace atmosphere, including bacterial endotoxin. A few studies have indicated potentially high endotoxin exposure with exposure to fresh wood in sawmills and in the production of fiberboard and chipboard, but fewer studies have been carried out on exposure to endotoxin in dry wood work, for example in joineries. A study of the endotoxin content of airborne wood dust samples from US woodworking facilities is presented, from the re-analysis of samples which previously had been taken to establish mass collection relationships between the IOM sampler, the closed-face 37 mm plastic cassette (CFC) sampler and the Button sampler. Endotoxin was strongly correlated with total dust, but the endotoxin content of a few fresh wood samples was found to be up to ten times higher per unit of wood dust than for dried-wood samples, and this difference was significant. No long-term time-weighted average sample exceeded the recommended limit value of 50 EU m(-3) (EU, endotoxin units)used in the Netherlands, although a number of the IOM samples came close (seven samples or 44% exceeded 20 EU m(-3)) and one short-term (48 minute) sample registered a high value of 73 EU m(-3). The geometric mean concentration from the IOM samples (11 EU m(-3)) is within the range of geometric means found from Australian joineries (3.7-60, combined: 24 EU m(-3)). In contrast, the corresponding values from the CFC (3.6 EU m(-3)), and the Button sampler (2.1 EU m(-3)) were much lower and no samples exceeded 20 EU m(-3). Endotoxin is likely only to be a significant problem in working with dried woods when associated with very high dust levels, where the wood dust itself is likely to be a cause for concern. The results from the few samples in this study where fresh wood was being worked were similar to results from other studies involving fresh woods. The agreement between these studies is encouraging given the difficulties of endotoxin analysis and the wide variation often expected between different laboratories.  相似文献   

11.
In this study, air samples were taken using a BioSampler and gelatin filters from six sites in Beijing: office, hospital, student dormitory, train station, subway, and a commercial street. Dust samples were also collected using a surface sampler from the same environments. Limulus amoebocyte lysate (LAL) and Glucatell assays were used to quantify sample endotoxin and (1,3)- ${\rm{\beta}} $ -d-glucan concentration levels, respectively. Enzyme-linked immunosorbent assay (ELISA) was used to measure the dust mite allergens (Der p 1 and Der f 1). Ultrafine particle and lead concentrations in these sampling sites were also measured using P-Trak and atomic absorption spectrometer, respectively. Analysis of variance (ANOVA) and linear regression analysis were used to analyze the concentration data. Higher culturable bacteria (12,639 CFU/m3) and fungi (1,806 CFU/m3) concentrations were observed for the train station and the subway system, respectively. For the rest of sampling sites, their concentrations were comparable to those found in western countries, ranging from 990 to 2,276 CFU/m3 for bacteria, and from 119 to 269 CFU/m3 for fungi. ANOVA analysis indicated that there were statistically significant differences between the culturable bacterial and fungal concentration levels obtained for different sites (p value = 0.0001 and 0.0047). As for dust allergens, endotoxin, and (1,3)-β -d-glucan, their concentrations also seemed to be comparable to those found in the developed countries. Airborne allergen concentrations ranged from 16 to 68 ng/m3. The dust-borne allergen concentration was observed to range from 0.063 to 0.327 ng/mg. As for endotoxin, the highest airborne concentration of 25.24 ng/m3 was observed for the commercial street, and others ranged from 0.0427 to 0.1259 ng/m3. And dust-borne endotoxin concentration ranged from 58.83 to 6,427.4 ng/mg. For (1,3)-β -d-glucan, the airborne concentration ranged from 0.02 to 1.2 ng/m3. Linear regression analyses showed that there existed poor correlations between those in airborne and dust-borne states (R2?=?0.002~0.43). In our study, the lowest ultrafine particle concentration about 5,203 pt/cm3 was observed in office and the highest was observed at the train station, up to 32,783 pt/cm3. Lead concentration was shown to range from 80 to 170 ng/mg with the highest also observed at the train station. The information provided in this work can be used to learn the general situation of relevant health risks in Beijing. And the results here suggested that when characterizing exposure both airborne and dust-borne as well as the environments should be considered.  相似文献   

12.
Contamination by cadmium in the environment is of great concern because of its toxicity and threats to human and animal health. The current study was conducted to investigate the effects of a cadmium contaminated diet on the osmoregulation and urine concentration mechanisms of the semi-desert rodent Meriones shawi and eventual accumulation of this metal in vital organs such as the kidneys, which are directly implicated in water regulation. Originally, we used Differential Pulse Anodic Stripping Voltammetry (DPASV) to avoid the matrix interference due to the highly organic content in the biological samples. Our results show that Meriones shawi successfully maintained a homeostasis state and presented a special adaptation to regulate urine volume during cadmium exposure by decreasing diuresis and increasing urinary osmolality. The plasma osmolality and hematocrit remained constant throughout the experiment. The stripping signals of cadmium are linear up to 0.3-100 μg L(-1) range, with a detection limit of 0.28 μg L(-1). The DPASV technique was useful for easy, fast, selective and sensitive determination of Cd, which permits working at cellular concentration. This gives us more information about the chemical form in which Cd is introduced into the organ, as well as the intracellular Cd quantities. This study has potential importance if this valuable novel animal model, imitating human and animal environmental chronic exposure to Cd, could serve as an appropriate terrestrial biomonitor for Cd contaminated sites. These results are encouraging in the context of developing a low-cost and fast technology for the detection of pollutants and for studying the impairment caused by their effects.  相似文献   

13.
A high-performance liquid chromatography (HPLC) method for biomonitoring of occupational wood dust exposure based on nasal lavage as a biomonitoring matrix was developed. Gallic acid (GA) was chosen as the indicator compound for oak dust exposure. From the chromatographic profile of ash dust, four peaks were chosen as indicator compounds. Phenolic indicator compounds were analysed by HPLC. Personal dust samples and corresponding nasal lavage samples were collected from 16 workers exposed to oak dust and six to ash dust. The dust concentrations in the workers' breathing zone varied between 0.7 and 13.8 mg m(-3). The indicators revealed the nature of the wood dust inhaled. For the workers who did not use respirators, the correlation between the dust and corresponding indicator compound in their nasal lavage was significant; r2 = 0.59 (n = 12) for oak dust and r2 = 0.58 (n = 6) for ash dust, respectively. Further, the correlation for oak dust workers who used respirators was r = 0.67 (n = 4). Nasal lavage sampling and HPLC analysis of polyphenol indicator compounds are promising tools for measuring wood dust exposure. Although further validation is necessary, determination of the individual dose may prove invaluable in prospective epidemiological studies.  相似文献   

14.
15.
Inhalation of immunomodulating mycotoxins produced by Fusarium spp. that are commonly found in grain dust may imply health risks for grain farmers. Airborne Fusarium and mycotoxin exposure levels are mainly unknown due to difficulties in identifying Fusarium and mycotoxins in personal aerosol samples. We used a novel real-time PCR method to quantify the fungal trichodiene synthase gene (tri5) and DNA specific to F. langsethiae and F. avenaceum in airborne and settled grain dust, determined the personal inhalant exposure level to toxigenic Fusarium during various activities, and evaluated whether quantitative measurements of Fusarium-DNA could predict trichothecene levels in grain dust. Airborne Fusarium-DNA was detected in personal samples even from short tasks (10-60 min). The median Fusarium-DNA level was significantly higher in settled than in airborne grain dust (p < 0.001), and only the F. langsethiae-DNA levels correlated significantly in settled and airborne dust (r(s) = 0.20, p = 0.003). Both F. langsethiae-DNA and tri5-DNA were associated with HT-2 and T-2 toxins (r(s) = 0.24-0.71, p < 0.05 to p < 00.01) in settled dust, and could thus be suitable as indicators for HT-2 and T-2. The median personal inhalant exposure to specific toxigenic Fusarium spp. was less than 1 genome m(-3), but the exposure ranged from 0-10(5) genomes m(-3). This study is the first to apply real-time PCR on personal samples of inhalable grain dust for the quantification of tri5 and species-specific Fusarium-DNA, which may have potential for risk assessments of inhaled trichothecenes.  相似文献   

16.
Initiated in 1992, air monitoring of organic pollutants in the Canadian Arctic provided spatial and temporal trends in support of Canada's participation in the Stockholm Convention of Persistent Organic Pollutants. The specific analytical laboratory charged with this task was changed in 2002 while field sampling protocols remained unchanged. Three rounds of intensive comparison studies were conducted in 2004, 2005, and 2008 to assess data comparability between the two laboratories. Analysis was compared for organochlorine pesticides (OCPs), polychlorinated biphenyls (PCBs) and polycyclic aromatic hydrocarbons (PAHs) in standards, blind samples of mixed standards and extracts of real air samples. Good measurement accuracy was achieved for both laboratories when standards were analyzed. Variation of measurement accuracy over time was found for some OCPs and PCBs in standards on a random and non-systematic manner. Relatively low accuracy in analyzing blind samples was likely related to the process of sample purification. Inter-laboratory measurement differences for standards (<30%) and samples (<70%) were generally less than or comparable to those reported in a previous inter-laboratory study with 21 participating laboratories. Regression analysis showed inconsistent data comparability between the two laboratories during the initial stages of the study. These inter-laboratory differences can complicate abilities to discern long-term trends of pollutants in a given sampling site. It is advisable to maintain long-term measurements with minimal changes in sample analysis.  相似文献   

17.
Miners face a variety of respiratory hazards while on the job, including exposure to silica dust which can lead to silicosis, a potentially fatal lung disease. Currently, field-collected filter samples of silica are sent for laboratory analysis and the results take weeks to be reported. Since the mining workplace is constantly moving into new and often different geological strata with changing silica levels, more timely data on silica levels in mining workplaces could help reduce exposures. Improvements in infrared (IR) spectroscopy open the prospect for end-of-shift silica measurements at mine sites. Two field-portable IR spectrometers were evaluated for their ability to quantify the mass of silica on filter samples loaded with known amounts of either silica or silica-bearing coal dust (silica content ranging from 10-200 μg/filter). Analyses included a scheme to correct for the presence of kaolin, which is a confounder for IR analysis of silica. IR measurements of the samples were compared to parallel measurements derived using the laboratory-based U.S. Mine Safety and Health Administration P7 analytical method. Linear correlations between Fourier transform infrared (FTIR) and P7 data yielded slopes in the range of 0.90-0.97 with minimal bias. Data from a variable filter array spectrometer did not correlate as well, mainly due to poor wavelength resolution compared to the FTIR instrument. This work has shown that FTIR spectrometry has the potential to reasonably estimate the silica exposure of miners if employed in an end-of-shift method.  相似文献   

18.
This paper is the result of an investigation carried out in February 1997, which set out to learn about the development and application of occupational health standards, and in turn approaches to occupational environmental monitoring, in Russia, and to see how these were similar to, or different from, what takes place in other countries. The enquiry involved face-to-face meetings with senior Russian occupational health scientists and officials. It was confirmed that Russian occupational exposure standards are very stringent and provide a very high level of protection of workers. However, they are difficult to enforce, and it is suggested that the development of a strong and distinctive occupational hygiene discipline and profession in Russia would provide a "bridge" to enable more effective implementation and interpretation of those standards.  相似文献   

19.
A monitoring method for diesel particulate matter was published as Method 5040 by the National Institute for Occupational Safety and Health (NIOSH). Organic and elemental carbon are determined by the method, but elemental carbon (EC) is a better exposure measure. The US Mine Safety and Health Administration (MSHA) proposed use of NIOSH 5040 for compliance determinations in metal and nonmetal mines. MSHA also published a rulemaking for coal mines, but no exposure standard was provided. A standard based on particulate carbon is not considered practical because of coal dust interference. Interference may not be a problem if an appropriate size-selective sampler and EC exposure standard are employed. Submicrometer dust concentrations found in previous surveys of nondieselized, underground coal mines were relatively low. If a large fraction of the submicrometer dust is organic and mineral matter, submicrometer EC concentrations would be much lower than submicrometer mass concentrations. Laboratory and field results reported herein indicate the amount of EC contributed by submicrometer coal dust is minor. In a laboratory test, a submicrometer EC concentration of 31 microg m(-3) was found when sampling a respirable coal dust concentration over three times the US compliance limit (2 mg m(-3)). Laboratory results are consistent with surveys of nondieselized coal mines, where EC results ranged from below the method limit of detection to 18 microg m(-3) when size-selective samplers were used to collect dust fractions having particle diameters below 1.5 microm-submicrometer EC concentrations were approximate 7 microg m(-3). In dieselized mines, submicrometer EC concentrations are much higher.  相似文献   

20.
All major opencast mining activities produce dust. The major operations that produce dust are drilling, blasting, loading, unloading, and transporting. Dust not only deteriorates the environmental air quality in and around the mining site but also creates serious health hazards. Therefore, assessment of dust levels that arise from various opencast mining operations is required to prevent and minimize the health risks. To achieve this objective, an opencast coal mining area was selected to generate site-specific emission data and collect respirable dust measurement samples. The study covered various mining activities in different locations including overburden loading, stock yard, coal loading, drilling, and coal handling plant. The dust levels were examined to assess miners' exposure to respirable dust in each of the opencast mining areas from 1994 to 2005. The data obtained from the dust measurement studies were evaluated by using analysis of variance (ANOVA) and the Tukey-Kramer procedure. The analyses were performed by using Minitab 14 statistical software. It was concluded that, drilling operations produce higher dust concentration levels and thus, drill operators may have higher incidence of respiratory disorders related to exposure to dust in their work environment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号