共查询到17条相似文献,搜索用时 963 毫秒
1.
耐高温反渗透膜在化工废水处理中的应用 总被引:1,自引:0,他引:1
以某化工工艺废水的超滤出水为原水,采用耐高温反渗透膜进行处理,考察了操作压力、废水pH、膜面流速及废水总铁质量浓度对耐高温反渗透膜产水通量及脱盐率(以电导率减小率计,下同)和TOC去除率的影响。实验结果表明,在操作压力为0.24 MPa、废水pH为7.60、膜面流速为2.0 m/s的最佳条件下运行4 200 min后,产水通量衰减约73%,反渗透系统的脱盐率为95%~97%,TOC去除率为83%~95%,出水电导率在50μs/cm左右,出水TOC为21~23 mg/L。 相似文献
2.
针对膜蒸馏法处理石化反渗透浓水的膜面污染物进行了分析及清洗工艺优化研究。在反渗透浓水温度为73℃、渗透侧真空度为-0.093 MPa的条件下进行膜蒸馏实验,实验后期膜通量衰减迅速,脱盐率基本保持在99.5%以上,产水p H基本稳定在6.5~7.0。膜面污染物的SEM表征结果显示,膜蒸馏的膜面污染主要为碳酸钙、硅酸钙、氢氧化镁结垢污染和氯化钠、氯化钾等盐类结晶污染。实验结果表明:分别以盐酸和去离子水为清洗液静态浸泡清洗污染膜时,污染物的去除效果最好,Na OH溶液次之,草酸最差;分别采用盐酸和去离子水动态清洗污染膜,膜通量和脱盐率均能恢复到初始水平,随运行时间的延长,经去离子水清洗后膜的膜通量出现衰减。 相似文献
3.
4.
采用缺氧膨胀床(AEB)反应器处理高浓度硝酸盐废水,研究了反应器的快速启动和挂膜特性,以及在反硝化连续流运行条件下对废水的处理效果。实验结果表明:采用自然挂膜方式,填料层从下至上生物膜厚度逐渐增加;AEB的快速启动8 d可完成,COD去除率由44.9%升至92.3%,NO_3~--N去除率由39.8%升至98.4%;稳定运行阶段(进水COD 4 628~5 548 mg/L、ρ(NO_3~--N) 1 339~1 505 mg/L),COD去除率稳定在95%左右,NO_3~--N去除率稳定在98%~99%,COD和NO_3~--N的容积负荷去除量最高可达27.8 kg/(m~3·d)和7.3 kg/(m~3·d)。 相似文献
5.
采用活性污泥法处理有机磷酸酯综合废水,进行了探索试验和工艺条件优化试验。在进水 COD 为700毫克/升左右、污泥负荷为0.38—0.4公斤 BOD/公斤 MLSS.天、水力停留时间为9—10小时时,各项目的去除率为:COD84.7—91.3%,BOD95.7%左右,酚大于99.6%,总磷30—50%;达标率为:COD85.3%,BOD 和酚均接近100%。 相似文献
6.
采用芳香聚酰胺膜(NF-1#)、复合膜(NF-2#)和聚酰胺复合膜(NF-3#)深度处理棉针织品印染废水,考察了膜分离性能及膜污染情况的影响因素。实验结果表明,在操作压力为0.5MPa、废水温度为25~35℃、废水pH为7的条件下,NF-1#膜处理效果最佳,COD去除率最高,为76.0%~85.0%;脱盐率也最高,达90.0%。膜过滤后浓水送污水厂处理,产水回用于车间生产。操作压力增高、废水温度升高和废水pH增大均导致滤饼层阻力(Rc)和膜过滤过程中的总阻力(Rt)增加,Rc是Rt的主要组成部分,同时也是导致膜透过通量下降的主要因素。 相似文献
7.
8.
采用自制聚丙烯中空纤维疏水膜,开展了内压式真空膜蒸馏处理某气田采出水的实验研究,考察了膜通量、脱盐率、产水电导率及产水水质等随运行时间的变化,针对实验后期出现的膜污染情况对膜蒸馏浓水除硬后进行二段膜蒸馏,再对出水进一步做催化臭氧氧化处理。实验结果表明:105 h后,废水中各离子浓度随着废水的浓缩而急剧升高,同时废水的高硬度造成膜堵塞,产生膜污染;除硬后去除了膜结垢污染,改善了膜疏水性能,膜通量恢复到初始膜通量的73%;膜蒸馏出水经催化臭氧氧化处理后,出水COD、TOC和ρ(NH4+-N)分别为49 mg/L、6.5 mg/L和11.0 mg/L,满足回用要求。 相似文献
9.
超滤膜处理油田采出水及污染膜的微观分析 总被引:5,自引:1,他引:4
采用纳米Al2O3改性聚偏氟乙烯超滤膜处理油田采出水,分析了污染膜的结构和污染膜上的主要污染物.实验结果表明,超滤膜具有很好的通透性,稳定运行时膜通量达150 L/(m2·h).超滤出水中COD去除率大于90%,其他各项指标去除率均大于98%,超滤出水达到了低渗透油田回注水水质标准(SY/T 5329-94<碎屑岩油藏注水水质推荐指标及分析方法>).污染膜因污染物的存在而使其孔径和孔深度都比新膜减小.污染膜上的主要污染物为含有一定长碳链的烃类衍生物,主要是油田采出水中的油类物质.污染膜上的主要无机元素为Ca、Mg和Al,还有少量的Si、S及Fe. 相似文献
10.
11.
A leachate purification system, equipped with the thin open channel spiral wound modules, is studied in this paper. In Phase I, effluent from an activated sludge process followed by the flocculation/sedimentation process was fed into the landfill leachate treatment unit. After 2 wk of operation, the permeate flux dropped dramatically, from an average value of 6.5l/m(2)/h to 4.23 l/m(2)/h. The significant decline of membrane flux was likely caused by membrane fouling. In Phase II, raw leachate was fed directly into the reverse osmosis leachate treatment system. An average flux of 7.8l/m(2)/h was maintained at an initial trans-membrane pressure difference of 20 bar, which increased to 40 bar before membrane chemical cleaning. An average recovery rate of 70% was achieved. Throughout the observation in Phase II, an average reduction rate of 98.2% for the dissolved solids was obtained. The reduction rate of COD was greater than 99.5% with a constant level of the permeate COD. Chloride was eliminated by more than 99%, while over 98% of NH(4)-N was reduced. A negligible permeate flux drop was observed after cleaning the membrane effectively. The study shows that direct reverse osmosis membrane filtration with thin open channel spiral wound modules is able to achieve satisfactory results in terms of water quality, process stability and membrane flux. The obtained quality of the permeate quality in this study met the German standards for leachate discharge. At the end of each filtration cycle, the membrane was maintained through alkaline chemical cleaning in order to remove any irreversible membrane fouling. After the maintenance procedure, the membrane flux was found to recover to the initial value. 相似文献
12.
13.
14.
15.
16.
17.
采用预处理-超滤-反渗透工艺深度处理某炼油厂污水场的二沉池出水。预处理单元出水COD为40mg/L,ρ(NH3-N)为1mg/L,SS为6.3mg/L,能够满足超滤-反渗透系统的进水要求。超滤单元进水压力在0.04~0.08MPa波动,反渗透单元进水压力在0.92~1.12MPa波动,运行均稳定,化学清洗周期均可超过一个月。预处理-超滤-反渗透工艺产水回用于二级脱盐装置脱盐水补水的成本为每吨产水2.04元,低于企业现有的新鲜水每吨3.45元的费用。该优质产水取代新鲜水回用,每年可为企业节约100多万元。 相似文献