首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
As national trends accelerate towards the reduction of ventilation and infiltration rates in buildings, coupled with an increased use of synthetic chemicals in the indoor environment, a new phenomenon has arisen: the “sick building” syndrome. Traditional approaches to environmental health developed for the outdoor air, or for the industrial occupational setting, are inadequate to deal with this problem. It is argued that a comprehensive approach to the problem of indoor air pollution is necessary to protect public health.  相似文献   

2.
A sample of 58 occupied homes in Rochester, NY, most of which incorporated special builder-designed weatherization components, were studied to assess (1) the effectiveness of construction techniques designed to reduce air leakage; (2) the indoor air quality and air-exchange rates in selected airtight houses, and (3) the impact on indoor air quality of mechanical ventilation systems employing air-to-air heat exchangers. The “specific leakage area” was measured in each house using the fan pressurization technique. Houses built with polyethylene vapor barriers and joint-sealing were as a group 50% tighter than a similar group of houses without such components. Mechanical ventilation systems with air-to-air heat exchangers were installed in nine relatively airtight houses, some of which had gas stoves and/or tobacco smoking occupants. Air-exchange rates and indoor concentrations of radon (Rn), formaldehyde (HCHO), nitrogen dioxide (NO2), and humidity were measured in each house for 1-week periods with and without mechanical ventilation. More detailed measurements, including concentrations of carbon monoxide and inhalable particulates, were made in two of these houses by a mobile laboratory. In all nine houses, air-exchange rates were relatively low (0.2–0.5 ach) without mechanical ventilation, and yet indoor concentrations of Rn, HCHO, and NO2 were below existing guidelines. Mechanical ventilation systems were effective in further reducing indoor contaminant concentrations. We conclude that when contaminant source strengths are low, acceptable indoor air quality can be compatible with low air-exchange rates.  相似文献   

3.
In recent years, scientist have come to realize that contaminated air inside buildings is a major route of human exposure to certain air pollutants. While scientific interest in the problem continues to grow, efforts to measure indoor pollution concentrations, define exposure levels, and estimate health risks remain in their infancy. Within this arena, policymakers must deal with the question of how best to protect public health and safety in the face of incomplete and often contradictory information. In the past, official response to environmental pollution has traditionally taken the form of “control by regulation.” However, creation of a regulatory framework for indoor air quality poses special policy issues that suggest the need to explore alternative modes of intervention. Ambient outdoor air is a public good, in the sense that enjoyment by one individual in no way detracts from use or enjoyment by others. Indoor air, on the other hand, is not a public good, especially in private residences. Costs and benefits of maintaining adequate indoor air quality are internalized within households, suggesting the possibility of a private demand for clean indoor air. Promulgation of indoor air quality standards and other regulations must confront the fact that individuals are already making decisions about their own air quality. Regulations might or might not improve these decisions. Development of effective and reasonable policy requires an appreciation of the scope for private action and consideration of the likelihood that public intervention will foster improved private choices. Among the logical and relatively inexpensive modes of intervention are public information programs, development of simple warning devices, and product testing and labeling.  相似文献   

4.
5.
Ambient temperature may influence both the emission and the perception of human odor. This paper studies how human odor is perceived at different temperatures. The intensity of human odor in an auditorium was judged by an odor panel in an adjacent space. The ventilation rate of the occupied auditorium was 5–17 L/sec person. A continuous sample of odorous air was exhausted from the auditorium through a glass tube to an odor test station. One-half of the air flow was heated 1–7 K, and the other half was unheated. The odor panel was asked to compare the odor intensity of the two air flows. The air flow judged to have the strongest odor was stepwise dilluted with clean air (air temperature difference maintained). The dilution required to provide the same odor intensity in the two air flows was estimated. At air temperatures 23–32 °C no significant influence of temperature on perceived intensity of body odor was found. The ventillation requirement in auditoria and similar spaces is likely to be independent of the temperature level, provided that the occupants are kept thermally neutral or cooler, so that little or no perspiration occurs.  相似文献   

6.
A subcommittee of the Nordic Committee for Building Codes has released guidelines for building regulations regarding indoor air quality, especially concerning ventilation. The main features of the guidelines, such as acceptable outdoor air quality for ventilation and minimum outdoor air flows for dwellings and offices, are presented and discussed. Mechanical ventilation is, in principle, required in all buildings including dwellings, due to the requirement of a minimum outdoor air change of 0.5 h−1 and the normal highly airtight nature of new buildings. The guidelines are a basis for designing energy-efficient buildings while maintaining an indoor air quality which provides acceptable comfort and does not impair health.  相似文献   

7.
A complete assessment of the health effects of diesel emissions must take into account the possible chemical transformations (and associated biological impacts) of particulate organic matter (POM) due to reactions with the many gaseous copollutants which have now been unambiguously demonstrated to be present in atmospheres burdened by photochemical air pollution. These copollutants include the “trace” species, nitric (HNO3) and nitrous (HONO) acids, the nitrate radical (NO3), formaldehyde (H2CO) and formic acid (HCOOH), as well as the criteria pollutants, ozone (O3) and nitrogen dioxide (NO2). Techniques for establishing the atmospheric concentrations of the trace pollutants (and their spatial and temporal variations) are briefly described, and we present results of investigations into the reactions of polycyclic aromatic hydrocarbons (PAH) coated on filters and exposed to ambient concentrations of O3 and NO2. Environmental health implications of these results are discussed and include the potential for sampling “artifacts” and their possible effects on the correlation (or lack thereof) between ambient PAH levels and urban lung cancer rates, as well as the problems associated with understanding the appropriate POM “dose” to be employed in animal testing and assessments of impacts on human health.  相似文献   

8.
Air pollution has been associated with an increased incidence of respiratory disease. However, significant differences may exist between air pollution levels measured at conventional fixed monitoring stations and actual levels inhaled by a subject. Furthermore, studies of effects of air pollution might best be done using asthmatics as study subjects, since they have irritable airways. This is a preliminary report of a study using a control and asthmatic group in which effects of air pollution are assessed by sympton and medication diaries and simple pulmonary function tests. Air pollution exposure is measured using a small portable sampler for particulates, SO2 and NO2; these samplers are carried by the subject (“personal”) and are situated inside and outside the home. Levels obtained are compared to data obtained from the same type of sampler located at a fixed monitoring station. Preliminary analysis of the data shows that the levels of pollutants are low and there are significant differences between the four air pollution measurements, with weak correlations among the various measurements. In this preliminary report, change in pulmonary function during the day correlates only with personal NO2 measurements. This suggests the need for estimating air pollution exposure using “personal” samplers, when investigating health effects.  相似文献   

9.
Allergic respiratory disease due to common allergens of organic origin is wwell known. Less familiar, but of increasing importance, are chemicals of organic and inorganic nature, met as dusts, vapours, and fumes. Their relevance is shown in occupational respiratory allergic disorders. Confirmation is given by “real life,” simulated, occupational-type provocation tests. Controlled exposure with minute amounts for brief periods, thus closely simulating allergic sensitivity, can precisely identify etiological causes in often complex exposures. The capacity of these widely different agents in different forms to elicit the different patterns of asthmatic reactions, is a pointed example of their potential role, as well as the role of chemical agents in general. The introduction into indoor environments of such materials demands consideration of their possible allergenic ffects and of the need to recognise the various forms of allergic respiratory reaction they may cause.  相似文献   

10.
The recovery of energy from the combustion of municipal solid wastes is becoming an attractive alternative as landfill space becomes scarce and the availability of fossil fuels decreases. Particulate emissions from “waste-as-fuel” processes, however, may differ significantly in chemical and physical properties from particulate emissions produced by firing only coal. Such differences can affect the design and operation of air pollution control equipment. Presented in this paper are the results of a 2-month test program at Ames, Iowa, with a mobile electrostatic precipitator (ESP) and a mobile scrubber supplied by the U.S. Environmental Protection Agency (EPA), Industrial Environmental Research Laboratory (IERL), Research Triangle Park. PEDCo Environmental, Inc., and Acurex Corporation jointly conducted the test program to examine the effect of burning refuse-derived fuel (RDF) on particulate and heavy metal control efficiencies. The mobile ESP was used only as a primary control device, whereas the mobile scrubber was tested both upstream and downstream of the existing full-scale ESP. This paper also presents a status report on a PEDCo test program with a pilot fabric filter at Ames.  相似文献   

11.
Results from a two-box model for calculation of tracer gas concentrations in rooms are given and consequences of different definitions of “ventilation efficiency” are discussed. Results from three different series of experiments are presented. The first two series were dilution experiments; examples of the results are given and discussed. The third series of tests was performed with one person working at a desk in the test room. Above the person;s head, a tracer gas (N2O) was injected into the convection plume, with as low momentum as possible. Starting with zero concentration, a test continued until steady-state conditions were established for the concentration levels in the different parts of the room. The tests included simulation of summer, autumn/spring, and winter daytime conditions. The results indicate a tendency towards lower tracer gas concentrations in the “breathing zone” when the supply air (typical flow rate equivalent to two air changes per hour) is brought into the room at a low level as compared to a high level close to the ceiling. The exhaust air terminal device in all tests was situated high in the “corridor” wall.  相似文献   

12.
13.
A standardized questionnaire was used in a two-year follow-up study to test the effectiveness of non-regulatory recommendations to improve indoor air quality of 103 ice arenas in Finland. In addition, the performance of a state-of-the-art emission control technology (ECT) on propane-fueled resurfacers was evaluated by measuring the one-week average nitrogen dioxide (NO2) concentration in a small sample of arenas. The number of retrofitted ECT on propane-fueled resurfacers increased from 6 to 37 (8% to 37% of ice arenas) and the number of electric resurfacers from 7 to 9 (both 9% of arenas) in 1994–1996. At the same time, the prevalence of inadequate ventilation increased among the most susceptible small arenas (volume <30 000 m3) from 11 (31%) to 19 (38%). Combustion-powered resurfacers (88%) and inadequate ventilation (24%) were prevalent also among the 17 new arenas built in 1994–1996. ECT resurfacers significantly decreased the mean indoor NO2 concentration of eleven arenas from 650 μg/m3 to 147 μg/m3. Thus, retrofitting resurfacers with ECT seems to be a feasible mitigation option to improve indoor air quality in ice arenas, but the ultimate solution is an electric ice resurfacer. Non-regulatory recommendations seem to be partially effective in abatement against the air quality problems, but additional regulatory measures are needed for full compliance in all arenas.  相似文献   

14.
The article describes the influence of wood preservatives on water bioceonosis. The “battery” of toxicology tests was used to cover luminescent bacteria test, algae growth inhibition test, crustacean and fish lethal tests. The test samples used were pure wood preservative and water after the wood preservative leaching from wood sample. It was observed that the wood preservative is leaching from the wood sample in 10% within 1 month of exposition. Achieved results indicate the necessity of toxic assessment of wood preservative after wood element protection.  相似文献   

15.
This paper re-proves and generalizes results by Hardin and Sweet on the time to absorption in certain Markov chains by using a theorem on the time to extinction in multitype branching processes. Renaming “absorption” as “death” and “state immediately before absorption” as “cause of death” makes possible an interpretation in terms of competing risks. This is of very limited value, however, due to the rather severe mathematical restrictions on the Markov chains at hand.  相似文献   

16.
Occurrence of flame retardants (FRs) in the indoor environment of highly flame-retarded public facilities is an important concern from the viewpoint of exposure because it is likely that FRs are used to a greater degree in these facilities than in homes. For this study, brominated flame-retardants (BFRs) and organophosphate flame-retardants and plasticizers (OPs), and brominated dibenzo-p-dioxins/furans (PBDD/DFs) were measured in eight floor dust samples taken from a Japanese commercial hotel that was assumed to have many flame-retardant materials. Concentrations of polybrominated diphenylethers (PBDEs) and hexabromocyclododecanes (HBCDs) varied by about two orders of magnitude, from 9.8–1700 ng/g (median of 1200 ng/g) and from 72–1300 ng/g (median of 740 ng/g), respectively. Concentrations of the two types of BFRs described above were most dominant among the investigated BFRs in the dust samples. It is inferred that BFR and PBDD/DF concentrations are on the same level as those in house and office dust samples reported based on past studies. Regarding concentrations of 11 OPs, 7 OPs were detected on the order of micrograms per gram, which are equivalent to or exceed the BFR concentrations such as PBDEs and HBCDs. Concentrations of the investigated compounds were not uniform among dust samples collected throughout the hotel: concentrations differed among floors, suggesting that localization of source products is associated with FR concentrations in dust. Passive air sampling was also conducted to monitor BFRs in the indoor air of hotel rooms: the performance of an air cleaner placed in the room was evaluated in terms of reducing airborne BFR concentrations. Monitoring results suggest that operation of an appropriate air cleaner can reduce both gaseous and particulate BFRs in indoor air.  相似文献   

17.
A pilot field study was conducted with nine members of the general public to measure carbon monoxide exposure using personal monitors. The principal study objectives were to design and evaluate the research protocol and the instrumentation performance for application to the conduct of a large-scale personal monitoring program. Integrated carbon monoxide exposure was monitored and recorded according to type of activity such as “commuting” or “at work” for approximately 45 days by each subject. All subjects except one were able to handle both the equipment and data recording requirements with no significant problems. Actual data recording responsibilities consumed less than 10 min daily. The data consisted of 355 person-days each over 6-h duration, and weekdays only, from which 8-h average personal exposure levels could be computed. The 9 ppm (μL/L) ambient air quality standard was exceeded on 22 person-days. Elevated carbon monoxide concentrations during the commuting activity were frequently associated with the exceedences.  相似文献   

18.
Given the shrinking spatial contrasts in outdoor air pollution in Switzerland and the trends toward tightly insulated buildings, the Swiss Cohort Study on Air Pollution and Lung and Heart Diseases in Adults (SAPALDIA) needs to understand to what extent outdoor air pollution remains a determinant for residential indoor exposure. The objectives of this paper are to identify determining factors for indoor air pollution concentrations of particulate matter (PM), ultrafine particles in the size range from 15 to 300 nm, black smoke measured as light absorbance of PM (PMabsorbance) and nitrogen dioxide (NO2) and to develop predictive indoor models for SAPALDIA. Multivariable regression models were developed based on indoor and outdoor measurements among homes of selected SAPALDIA participants in three urban (Basel, Geneva, Lugano) and one rural region (Wald ZH) in Switzerland, various home characteristics and reported indoor sources such as cooking. Outdoor levels of air pollutants were important predictors for indoor air pollutants, except for the coarse particle fraction. The fractions of outdoor concentrations infiltrating indoors were between 30% and 66%, the highest one was observed for PMabsorbance. A modifying effect of open windows was found for NO2 and the ultrafine particle number concentration. Cooking was associated with increased particle and NO2 levels. This study shows that outdoor air pollution remains an important determinant of residential indoor air pollution in Switzerland.  相似文献   

19.
A free-jet scrubber is an innovative gas cleaner in which the primary liquid/gas contacting takes place in the turbulent mixing zone emanating from a jet nozzle. The first such devices, powered by supersonic steam or air ejectors, were exceptionally effective cleaners but were criticized as being high-energy users. A great reduction in the energy consumption of free-jet scrubbers has been accomplished in the last four years, a feat which may seem in contradiction to the “contacting power rule.” An explanation of what is happening in these devices must take into account the effectiveness with which energy and water are utilized. thereby leading one to a somewhat circular definition of “effective contacting power.” The theoretical implication of this analysis is primarily to remind us that there are many paths between two states and some are more energy efficient than others. The practical value is that such analysis generates information which aids in choosing between several design options, a direct benefit of the various free-jet configurations.  相似文献   

20.
The institutional and legislative framework of Swedish environmental protection is presented with special reference to the role of consultation in the policy process. The functions and duties of the National Environment Protection Board, the Franchise Board for Environment Protection, the Environment Advisory Board, and the Product Control Board are outlined. The main thrust of the 1969 Environment Protection Act, the 1972 Hazardous Products Control Act, and the environmental impact assessment requirements of the Planning and Building Legislation is presented. The character of consultation within this framework is also discussed, with reference to the role of public participation and of organized regulated interests. It is found that the main functions of consultation in policy-making are “feeding back on former policy,” “foreseeing future policies,” and “canvassing for consensus.” In the stage of policy clarification, consultation is found to be a means of “catering for compliance” and “creating coherence.” In policy implementation, consultation is an important means of gathering information from parties possibly affected by implementative decisions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号