首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
This study characterized the emissions of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) from the stack flue gases of 17 industrial sources, which were classified into 10 categories. The results show that the mean PCDD/PCDF concentration of secondary zinc smelter (Zn-S) and secondary copper smelter (Cu-S) is 2.44 ng international toxic equivalent (I-TEQ)/Nm3 (N represents normal conditions at 0 degrees C, 760 mmHg), which was found to be significantly greater than that of industrial waste incinerators (mean concentration = 0.15 ng I-TEQ/Nm3). These results imply that the controlling of secondary metallurgical melting processes is more important than industrial waste incineration for the reduction of PCDD/PCDF emissions. The mean emission factors of cement production, Zn-S and Cu-S, are 0.052, 1.99, and 1.73 microg I-TEQ/t product, respectively. For industrial waste incineration, the mean emission factors of waste rubber, waste liquor, waste sludge, industrial waste solid (IWI)-1, IWI-2, IWI-3, and IWI-4 are 0.752, 0.435, 0.760, 6.64, 1.67, 2.38, and 0.094 microg I-TEQ/t feed, respectively. Most of the PCDD/PCDF emission factors established in this study are less than those reported in previous studies, which could be because of the more stringent regulations for PCDD/PCDF emissions in recent years.  相似文献   

2.
This study investigates the emissions of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) from four electric arc furnaces (EAFs) and eight secondary aluminum smelters (secondary ALSs) in Taiwan. The mean PCDD/F International-Toxicity Equivalents (I-TEQ) concentrations in the stack gases of these EAFs and secondary ALSs are 0.28 ng I-TEQ/Nm3 (relative standard deviation [RSD]= 100%) and 3.3 ng I-TEQ/Nm3 (RSD = 260%), respectively. The high RSDs, especially for those obtained from secondary ALSs, could be caused by the intrinsic differences in their involved feeding materials, furnace operating conditions, and air pollution control devices. The mean I-TEQ emission factor of PCDD/Fs for EAFs (1.8 microg I-TEQ/tonne-feedstock) is lower than that for secondary ALSs (37 microg I-TEQ/tonne-feedstock). This result might be because the involved furnace temperatures for secondary ALSs (650-750 degrees C) are lower than those for EAFs (1600-1700 degrees C), resulting in the deterioration of the combustion condition, leading to the formation of PCDD/Fs during the industrial process. This study found that the total PCDD/F emissions from EAFs (20 g I-TEQ/yr) and secondary ALSs (18 g I-TEQ/yr) are approximately 27, 53, and approximately 24, 49 times higher than those from municipal solid waste incinerators (MSWIs; 0.74 g I-TEQ/yr) and medical waste incinerators (MWIs; 0.37 g I-TEQ/yr), respectively; while those are 44 and 40% of total PCDD/F emission from sinter plants (45 g I-TEQ/ yr), respectively. Considering a more stringent emission limit has been applied to waste incinerators (0.1 ng I-TEQ/Nm3) in Taiwan lately, the results suggest that the control of the emissions from metallurgical processes has become the most important issue for reducing the total PCDD/F emission from industrial sectors to the ambient environment.  相似文献   

3.
Anderson DR  Fisher R 《Chemosphere》2002,46(3):371-381
Several countries have compiled national inventories of dioxin (polychlorinated dibenzo-p-dioxin [PCDD] and polychlorinated dibenzofuran [PCDF]) releases that detail annual mass emission estimates for regulated sources. High temperature processes, such as commercial waste incineration and iron ore sintering used in the production of iron and steel, have been identified as point sources of dioxins. Other important releases of dioxins are from various diffuse sources such as bonfire burning and domestic heating. The PCDD/F inventory for emissions to air in the UK has decreased significantly from 1995 to 1998 because of reduced emissions from waste incinerators which now generally operate at waste gas stack emissions of 1 ng I-TEQ/Nm3 or below. The iron ore sintering process is the only noteworthy source of PCDD/Fs at integrated iron and steelworks operated by Corus (formerly British Steel plc) in the UK. The mean waste gas stack PCDD/F concentration for this process is 1,2 ng I-TEQ/Nm3 based on 94 measurements and it has been estimated that this results in an annual mass release of approximately 38 g I-TEQ per annum. Diffuse sources now form a major contribution to the UK inventory as PCDD/Fs from regulated sources have decreased, for example, the annual celebration of Bonfire Night on 5th November in the UK causes an estimated release of 30 g I-TEQ, similar to that emitted by five sinter plants in the UK.  相似文献   

4.
Significant dioxin (polychlorinated dibenzo-para-dioxins (PCDDs)/polychlorinated dibenzo-furans (PCDFs)) pollution from a municipal solid waste incinerator was discovered in 1997 in Osaka prefecture/Japan. The cause and mechanism of pollution was identified by a detailed assessment of the environment and incinerator plant. The primary sources of PCDD/PCDF pollution were high dioxin releases from an intermittently operated waste incinerator with PCDD/PCDF emissions of 150 ng-TEQ/Nm3. PCDD/PCDF also accumulated in the wet scrubber system (3,000 μg TEQ/L) by adsorption and water recirculation in the incinerator. Scrubber water was air-cooled with a cooling tower located on the roof of the incinerator. High concentrations of dioxins in the cooling water were released as aerosols into the surrounding and caused heavy soil pollution in the area near the plant. These emissions were considered as the major contamination pathway from the plant. Decontamination and soil remediation in and around the incinerator plant were conducted using a variety of destruction technologies (including incineration, photochemical degradation and GeoMelt technology). Although the soil remediation process was successfully finished in December 2006 about 3 % of the waste still remains. The case demonstrates that releases from incinerators which do not use best available technology or which are not operated according to best environmental practices can contaminate their operators and surrounding land. This significant pollution had a large impact on the Japanese government’s approach toward controlling dioxin pollution. Since this incident, a ministerial conference on dioxins has successfully strengthened control measures.  相似文献   

5.
In April 1996 and 1998, the concentrations of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) were determined in 40 herbage samples collected in the neighborhood of a hazardous waste incinerator (HWI) under construction in Constanti (Catalonia, Spain). In April 2000, 20 months after the HWI began operating, herbage samples were again collected at the same sampling points in which samples had been taken in the previous surveys. PCDD/F concentrations ranged between 0.13 and 0.65 ng I-TEQ/kg (dry matter), with a median and mean values of 0.29 and 0.32 ng I-TEQ/kg (dry matter), respectively. The results were compared with those obtained in the 1996 (median, 0.53 ng I-TEQ/kg; mean, 0.61 ng I-TEQ/kg) and the 1998 (median, 0.23 ng I-TEQ/kg; mean, 0.31 ng I-TEQ/kg) surveys. While in the period 1996-1998 a significant decrease (49%, P < 0.001) in the mean PCDD/F levels was noted, in the period 1998-2000 an increase of 3% (P > 0.05) was found in the concentrations of PCDD/Fs. The analysis of the results suggests two potential hypotheses: either the emissions of PCDD/Fs from the HWI are not negligible, or the current PCDD/F emissions from other sources near the HWI remained at similar levels to those reached in 1998. Anyhow, an exhaustive evaluation of the present data shows an absence of notable PCDD/F contamination by the HWI in the area under its direct influence. It seems also probable that the decline in the atmospheric levels of PCDD/Fs due other emission sources of PCDD/Fs in this area is currently stopped.  相似文献   

6.
Municipal solid waste incinerators (MSWIs) have long been the major contributors of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) to ambient air in Taiwan. After stringent MSWI emission standards were introduced in 2001, the long-term continuous monitoring of flue gas and ambient air quality became necessary to ensure the effectiveness of the related control strategies. Three MSWIs and the surrounding ambient air were investigated in the current study for PCDD/F characteristics during 2006 to 2011. The average concentrations in the flue gas ranged from 0.008?~?0.0488 ng I-TEQ/Nm3, which is much less than the emission standard in Taiwan (0.1 ng I-TEQ/Nm3) (I-TEQ is the abbreviation of International Toxic Equivalent). This led to extremely low levels in the ambient air, 0.0255 pg I-TEQ/Nm3, much less than the levels seen in most urban areas around the world. Additionally, the results obtained using the Industrial Source Complex Short-Term Dispersion Model (ISCST3) indicate that the PCDD/F contributions from the three MSWIs to the ambient air were only in the range from 0.164?~?0.723 %. Principal component analysis (PCA) showed that the PCDD/Fs in the air samples had very similar characteristics to those from mobile sources. The results thus show that stringent regulations have been an effective control strategy, especially for urban areas, such as Taipei City.  相似文献   

7.
Yu BW  Jin GZ  Moon YH  Kim MK  Kyoung JD  Chang YS 《Chemosphere》2006,62(3):494-501
The metallurgy industry and municipal waste incinerators are considered the main sources of polychlorinated dibenzo-p-dioxin and dibenzofurans (PCDD/Fs) in many countries. This study investigated the emission factors and total emissions of PCDD/Fs and dioxin-like polychlorinated biphenyls (PCBs) emitted from metallurgy industries (including ferrous and nonferrous foundries) in Korea. The toxic equivalency (TEQ) emission factor of PCDD/Fs was the highest for secondary copper production, at 24451 ng I-TEQ/ton. The total estimated emissions of PCDD/Fs from these sources were 35.259 g I-TEQ/yr, comprising 0.088 g I-TEQ/yr from ferrous foundries, 31.713 g I-TEQ/yr from copper production, 1.716 g I-TEQ/yr from lead production, 0.111 g I-TEQ/yr from zinc production, and 1.631 g I-TEQ/yr from aluminum production. The total estimated annual amounts of dioxin-like PCBs emitted from these sources were 13.260 g WHO-TEQ/yr, comprising 0.014 g WHO-TEQ/yr from ferrous foundries, 12.675 g WHO-TEQ/yr from copper production, 0.170 g WHO-TEQ/yr from lead production, 0.017 g WHO-TEQ/yr from zinc production, and 0.384 g WHO-TEQ/yr from aluminum production. The highest emission factor was found for secondary copper smelting, at 9770 ng WHO-TEQ/ton.  相似文献   

8.
The effect of reaction time on formation of polychlorinated dibenzo-p-dioxins (PCDD) and dibenzofurans (PCDF) was studied under laboratory conditions in the system containing municipal waste incineration fly ash, activated carbon and copper chloride dihydrate at 300 degrees C in 99.999% N2 and N2 + 10% O2 atmosphere. The concentrations of tetra- to octa-chlorinated isomers as well as I-TEQ concentrations of toxic congeners are reported. The mechanism of PCDD and PCDF formation from chlorophenols and chlorinated biphenyls is discussed in the light of the time changes of PCDD/PCDF ratios.  相似文献   

9.
PCDD/PCDF reduction by the co-combustion process   总被引:1,自引:0,他引:1  
Lee VK  Cheung WH  McKay G 《Chemosphere》2008,70(4):682-688
A novel process, termed the co-combustion process, has been developed and designed to utilise the thermal treatment of municipal solid waste (MSW) in cement clinker production and reduce PCDD/PCDF emissions. To test the conceptual design; detailed engineering design of the process and equipment was performed and a pilot plant was constructed to treat up to 40 tonnes MSW per day. The novel process features included several units external to the main traditional cement rotary kiln: an external calcinations unit in which the hot gas calcined the limestone thus making significant energy savings for this chemical reaction; the lime generated was used in a second chamber to act as a giant acid gas scrubber to remove SOx and particularly HCl (a source of chloride); an external rotary kiln and secondary combustion unit capable of producing a hot gas at 1200 degrees C; a gas cooler to simulate a boiler turbogenerator set for electricity generation; the incorporation of some of the bottom ash, calcined lime and dust collector solids into the cement clinker. A PCDD/PCDF inventory has been completed for the entire process and measured PCDD/PCDF emissions were 0.001 ng I-TEQ/Nm(3) on average which is 1% of the best practical means [Hong Kong Environmental Protection Department, 2001. A guidance note on the best practicable means for incinerators (municipal waste incineration), BPM12/1] MSW incineration emission limit values.  相似文献   

10.
An experimental campaign was carried out on a hospital and cemetery waste incineration plant in order to assess the emissions of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and polycyclic aromatic hydrocarbons (PAHs). Raw gases were sampled in the afterburning chamber, using a specifically designed device, after the heat recovery section and at the stack. Samples of slags from the combustion chamber and fly ashes from the bag filter were also collected and analyzed. PCDD/Fs and PAHs concentrations in exhaust gas after the heat exchanger (200–350 °C) decreased in comparison with the values detected in the afterburning chamber. Pollutant mass balance regarding the heat exchanger did not confirm literature findings about the de novo synthesis of PCDD/Fs in the heat exchange process. In spite of a consistent reduction of PCDD/Fs in the flue gas treatment system (from 77% up to 98%), the limit of 0.1 ng ITEQ Nm−3 at the stack was not accomplished. PCDD/Fs emission factors for air spanned from 2.3 up to 44 μg ITEQ t−1 of burned waste, whereas those through solid residues (mainly fly ashes) were in the range 41–3700 μg ITEQ t−1. Tests run with cemetery wastes generally showed lower PCDD/F emission factors than those with hospital wastes. PAH total emission factors (91–414 μg kg−1 of burned waste) were in the range of values reported for incineration of municipal and industrial wastes. In spite of the observed release from the scrubber, carcinogenic PAHs concentrations at the stack (0.018–0.5 μg Nm−3) were below the Italian limit of 10 μg Nm−3.  相似文献   

11.
This report presents results of emission measurements of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) in the flue gas of seven oil, nine gas, and two wood firing systems under laboratory conditions. The burn rate of the combustion was in the range of the rated useful heat output. Two additional test series varied the amount of combustion air and thus the heat output. The PCDD/PCDF emissions for oil- and gas-fired boilers are in the range of 0.0020-0.0142 ng I-TEQ/m3 (referring to 3% O2 in the dry flue gas). No correlation between the combustion technique and the PCDD/PCDF emissions could be established. In the tests with the wood-fired furnaces PCDD/PCDF concentrations in the flue gas ranging from 0.014 to 0.076 ng I-TEQ/m3 (referring to 13% O2 in the dry flue gas) were found. A significant correlation between the firing rate of the heating insert and the measured PCDD/PCDF concentrations was found. On examination of three typical 2,3,7,8-CDD/CDF congener profiles, a comparable pattern could be observed with natural gas and light fuel oil. The congener distribution for wood combustion is considerably different.  相似文献   

12.
Steps towards a European dioxin emission inventory   总被引:7,自引:0,他引:7  
Quass U  Fermann MW  Bröker G 《Chemosphere》2000,40(9-11):1125-1129
The results of a project aiming at collection and evaluation of information regarding the industrial and non-industrial emission sources for dioxins and furans (PCDD/PCDF) in 17 European Countries (EU 15, CH, N) are presented. An overview about national documents covering dioxin emission inventories for the period 1990-1995 is given. Some data on emissions associated with residual materials, waste and waste water are presented additionally. Based on the air emission data contained in these documents the most important emission sources were determined which are assumed to cover about 90% of the overall emissions. For the selected sources and for all 17 countries new estimates of the atmospheric PCDD/PCDF emissions were derived from average emission factors and statistical activity rates for the year 1994. As a result, on the European scale the largest annual PCDD/PCDF emission is assessed to be released from municipal waste incineration, quite closely followed by emissions from iron ore sintering. Considerable releases of dioxins and furans--based, however, on highly uncertain data--are further assessed for domestic burning, accidental fires and (former) use of contaminated wood preservatives (pentachlorophenol). A lower but still significant emission is further assigned to the sector of non-ferrous metal production; particular processes used in this branch proved to generate very high PCDD/PCDF flue gas concentrations.  相似文献   

13.
Dated sediment cores provide an excellent way to investigate the historical input of persistent organic pollutants into the environment and to identify possible sources of pollution. The vertical distribution of polychlorinated dibenzo-p-dioxins/polychlorinated dibenzofurans (PCDD/F) and polychlorinated biphenyls (PCB) was investigated in a sediment core from Greifensee to elucidate the historical trends of PCDD/F and PCB inputs between 1848 and 1999. Concentrations of PCB and PCDD/F increased by more than one order of magnitude between 1930 and 1960. PCB and PCDD/F concentrations were 5700 ng/kg dry weight (dw) and 160 ng/kg dw, respectively, in sediments originating from the late 1930s and reached a maximum of 130,000 ng/kg dw and 2400 ng/kg dw, respectively, in the early 1960s. From 1960 on, concentrations decreased to the 1930s level by the mid 1980s. A remarkable shift in the PCDD/F pattern was observed after the early 1940s. Before 1940, the PCDD/F pattern was PCDF dominated (ratio of PCDD to PCDF=0.41+/-0.11), while the PCDD started to be the major species after the early 1940s (ratio of PCDD to PCDF=1.46+/-0.38). The temporal trends of PCB and PCDD/F correlate surprisingly well with each other. This might be due to the coincidence of two factors. The introduction of PCB on the market in the 1930s resulted in emissions due to the widespread use of these industrial chemicals. In the same time period, waste incineration became an increasingly popular way to get rid of garbage, boosting the PCDD/F emissions significantly. The rapid decline of PCDD/F and PCB concentrations in the sediment starting in the early 1960s reflects the result of better emission control techniques in thermal processes and the improvement of waste water treatment in the catchment of Greifensee.  相似文献   

14.
Atmospheric concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/F) compounds were investigated at three different regions of Istanbul which reflect urban, urban/industrial, and sub-urban characteristics. Air samples were collected simultaneously for both gaseous and particulate phases using high volume samplers on monthly time intervals from May 2011 to October 2012. The highest concentrations (3,056 fg/m3 and 156 fg I-TEQ/m3) were observed at the sampling site that reflects traffic, residential, and industrial emission source characteristics, while the lowest concentrations (829 fg/m3 and 38 fg I-TEQ/m3) were observed at the sampling point which is far away from centrum and reflects sub-urban characteristics. Concentrations of PCDD congeners were, in general, found to be higher than PCDF congeners, and OCDD, 1,2,3,4,6,7,8-HpCDD/F, and OCDF congeners were recorded to be the most abundant congeners. Winter season concentrations were also found to be higher especially in particulate phase. As a result, combustion processes such as motor vehicles and residential heating equipment were thought to be the principal sources of emissions of PCDD/F compounds when both congener profiles and seasonal variations are considered. Basic statistical evaluation of the data resembled high degree of inverse correlations between PCDD/F concentrations and UV and solar radiation.  相似文献   

15.
Over the past decades in China, the number of medical waste incinerators (MWIs) has been rising rapidly, causing emissions of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). In this study, samples of fly ash, ash deposits, and bottom ash from typical MWIs were analyzed for PCDD/Fs and their distribution characteristics. Results showed international toxic equivalent (I-TEQ) values in the range of 6.9–67 ng I-TEQ/g in fly ash and ash deposits, whereas the concentration in bottom ash was extremely low (only 1.33 pg I-TEQ/g), yet the generation of PCDD/Fs was mostly de novo synthesis in fly ash and ash deposits according to the ratio of PCDFs to PCDDs; the major distribution differences of PCDD/Fs in fly ash was manifested by the content of toxic furan 2,3,7,8-TCDF, but other toxic PCDD/Fs showed similar distribution. Other findings are that 2,3,4,7,8-PeCDF had the most contribution to TEQ concentration, and that the most abundant toxic furan congener is 1,2,3,4,6,7,8-HpCDF. Correlation analysis showed that there was no significant correlation between PCDD/Fs concentration and several other physical and chemical parameters.

Implications: This paper is of interest because it presents the emission performances of PCDD/Fs in ash from medical waste incineration in China. PCDD/F contents in fly ash and ash deposits vary between 6.9 and 67.3 ng I-TEQ/g. However, the concentration in bottom ash was extremely low (only 1.33?×?10?3 ng I-TEQ/g). The fingerprints of PCDD/Fs in fly ash are almost similar, except for 2,3,7,8-TCDF. There is no marked correlation between PCDD/Fs and other physicochemical properties.

Supplemental Materials: Supplemental materials are available for this paper. Go to the publisher's online edition of the Journal of the Air & Waste Management Association.  相似文献   

16.
The concentrations of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) were determined in plasma samples of 20 nonoccupationally exposed subjects living in the vicinity of a new hazardous waste incinerator (HWI), now under construction in Tarragona (Catalonia, Spain). The mean PCDD/F value was 27.0 pg I-TEQ/g lipid with a range from 14.8 to 48.9 pg I-TEQ/g lipid. All samples showed higher PCDD than PCDF levels. Although PCDD/F concentrations were higher in women (27.7 pg I-TEQ/g lipid) than in men (25.2 pg I-TEQ/g lipid), the difference was not statistically significant. While a significant correlation (r = 0.565, p < 0.01) between the age of the subjects and the levels of PCDD/F in plasma could be observed, no significant differences were found in relation to the specific residential area. The plasma concentrations of PCDD/F obtained in the current study are discussed and compared with the results of similar investigations reported in the last two years.  相似文献   

17.
Abad E  Caixach J  Rivera J 《Chemosphere》2003,50(9):1175-1182
This study presents the results of a dioxin abatement programme undertaken in the municipal waste incineration plant of Montcada i Reixac (Barcelona, Spain) after the replacement of an obsolete air cleaning device by a new flue gas treatment system. A number of sampling campaigns were conducted with the aim of characterising stack gas emission levels of polychlorinated dibenzo-p-dioxins (PCDDs)/polychlorinated dibenzofurans (PCDFs) and to evaluate initial specifications of dioxin stack gas emission values below 0.1 ng I-TEQ/Nm(3). Preliminary results revealed levels between 44 and 111 ng I-TEQ/Nm(3) when the gas-cleaning system consisted only of an old electrostatic precipitator (ESP). Decreased levels around 15 ng I-TEQ/Nm(3) were observed when the semi-dry scrubber began to operate and the ESP was switched off. Again, remarkable dioxin removal was observed after the installation of the fabric filter and levels around 0.3-0.4 ng I-TEQ/Nm(3) were soon achieved. Nevertheless, the limit of 0.1 ng I-TEQ/Nm(3) was reached by additional injection of activated carbon which helped to lower PCDD/PCDF levels to around 0.036 ng I-TEQ/Nm(3). The results also demonstrated a significant change in the dioxin distribution present in combustion-derived materials (stack gas emission, bottom ash and solid waste from gas treatment). The major dioxin fraction was found in gaseous matrices before the flue gas control system was upgraded. After this step, the major dioxin fraction content was observed in solid waste from gas treatment.  相似文献   

18.
After entry into force of the Stockholm Convention and Aarhus Protocol and in order to implement the upcoming European legal background, the European countries are asked to apply control measures to reduce the release of persistent organic pollutants (POPs) such as dioxins and furans (PCDD/PCDF) and polychlorinated biphenyls as well as to establish POPs release inventories. In this perspective, development of measuring techniques of emissions is a focal issue in acquiring useful information. In this paper, results of various measurement campaigns at different municipal waste incineration (MWI) plants using long-term automated sampling of PCDD/PCDF are presented. The samples collected from both manual and automated campaigns were analyzed following the European Standard EN-1948:2006 by high-resolution gas chromatograph/high-resolution mass spectrometer. Performances of two different commercial systems have been investigated. Anomalous values occurred during one long-term campaign (22.16 pg I-toxic equivalent (TEQ)/Nm(3)), compared to average values (4-5 pg I-TEQ/Nm(3)) of the MWI. At this maximum value, a main occurrence of abnormal and instable operating conditions has been found. Sampling based on long-term basis was found to be more reliable to monitor PCDD/PCDF emissions than occasional short-term sampling. Nevertheless, the results of long-term campaigns demonstrate that emission levels detected in 15-30 days campaigns, when unsteady operating conditions can occur, as start-up and shut down, are not immediately comparable to the typical levels in a 6-8 h, when operating conditions are generally stable. Moreover, there are often differences observed in the congener profiles between short- and long-term campaigns.  相似文献   

19.
Liu HM  Lu SY  Buekens AG  Chen T  Li XD  Yan JH  Ma XJ  Cen KF 《Chemosphere》2012,86(3):300-307
In order to determine the baseline contamination by polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) in different areas in China, prior to the construction of municipal solid waste incinerators (MSWIs), a total of 32 representative soil samples was collected near 16 incinerators and analyzed for their PCDD/F concentrations. The PCDD/F baseline concentrations in the soil samples ranged from 0.32 to 11.4 ng I-TEQ kg−1 (dry matter), with average and median value of 2.73 and 2.24 ng I-TEQ kg−1 (dry matter), respectively, and a span between maximum and minimum recorded value of 36. The PCDD homologues predominated in 26 out of 32 soil samples, with the ratio (PCDDs)/(PCDFs) ranging from 1.1 to 164; however in the other 6 samples, PCDF homologues were larger, with the same ratio varying from 0.04 to 0.8. Principal component analysis (PCA) and hierarchical cluster analysis (HCA) were used to examine PCDD/F amount and profile in these soil samples, and their possible associations with known emission sources: in this process 6 really distinct isomer fingerprints were identified. Background PCDD/F levels and profiles were comparable to those found in soils from China and other countries and indicate a rather low baseline PCDD/F contamination of soils. The present data provide the tools for future assessment of a possible impact of these MSWIs.  相似文献   

20.
The levels of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) were determined in soil and vegetation samples taken from 24 sites in the vicinity of an old municipal solid waste incinerator (San Adrià del Besòs, Barcelona, Spain). Duplicate samples were collected within a radius of 3 km from the stack. PCDD/F concentrations in soils ranged from 1.22 to 34.28 ng I-TEQ/kg (d.m.) with median and mean values of 9.06 and 12.24 ng I-TEQ/kg, respectively. In turn, the levels of PCDD/Fs in vegetation samples ranged from 0.33 to 1.98 ng I-TEQ/kg (d.m.), with median and mean values of 0.58 and 0.70 ng I-TEQ/kg, respectively. Although the present PCDD/F concentrations in soil samples were higher than those recently found in soils taken near other incinerators from Catalonia, they are of the same order of magnitude than the levels of these pollutants found in incinerators from other countries. By contrast, the concentrations of PCDD/Fs in herbage samples were comparable to those found in recent surveys carried out in Catalonia.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号