首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 24 毫秒
1.
Trickle-bed air biofilters (TBABs) are suitable for treating volatile organic compounds (VOCs) at a significantly high practical loading because of their controlled environmental conditions. The application of TBAB for treating styrene-contaminated air under periodic backwashing and cyclical nonuse periods at a styrene loading of 0.64-3.17 kg chemical oxygen demand (COD)/m3 x day was the main focus of this study. Consistent long-term efficient performance of TBAB strongly depended on biomass control. A periodic in situ upflow with nutrient solution under media fluidization, that is, backwashing, was approached in this study. Two different nonuse periods were employed to simulate a shutdown for equipment repair or during weekends and holidays. The first is a starvation period without styrene loading, and the second is a stagnant period, which reflects no flow passing through the biofilter. For styrene loadings up to 1.9 kg COD/m3 x day, removal efficiencies consistently above 99% were achieved by conducting a coordinated biomass control strategy, that is, backwashing for 1 hr once per week. Under cyclical nonuse periods for styrene loadings up to 1.27 kg COD/m3 x day, stable long-term performance of the biofilter was maintained at more than 99% removal without employing backwashing. No substantial impact of nonuse periods on the biofilter performance was revealed. However, a coordinated biomass control by backwashing subsequently was unavoidable for attaining consistently high removal efficiency at a styrene loading of 3.17 kg COD/m3 x day. As styrene loading was increased, reacclimation of the biofilter to reach the 99% removal efficiency following backwashing or the nonuse periods was delayed. After the non-use periods, the response of the biofilter was a strong function of the biomass in the bed. No significant difference between the effects of the two different nonuse periods on TBAB performance was observed during the study period.  相似文献   

2.
Abstract

In this research, pilot-scale trickle bed biofilter systems have been analyzed to determine their effectiveness in controlling toluene in waste gas streams. These studies evaluated two synthetic microbial attachment media—a monolithic channelized medium and a pelletized ceramic medium. Operational parameters considered included toluene loading, empty bed residence time (EBRT), temperature, and long-term operation. The channelized medium provided 99% removal efficiency for a toluene loading of 0.725 kg COD/m3-day during the initial stages. However, continuous operation resulted in reduced and erratic efficiencies, due to air channeling caused by random plugging. After biomass accumulated within the channels and was subsequently removed by hosing, performance of the channelized medium never regained the previous levels. Similarly, the pelletized medium exhibited consistently good performance until the accumulation of excess biomass in the medium interstices also caused overall performance to deteriorate.

Implementation of a suitable backwashing strategy for biomass control was achieved for the pelletized medium by using full medium fluidization. This strategy permitted long-term operation of the biofilter at a toluene loading of 2.27 kg COD/m3-day and 1 minute EBRT, with efficiencies consistently over 99% and no appreciable back-pressure development between successive periods of backwashing.  相似文献   

3.
Cai Z  Kim D  Sorial GA 《Chemosphere》2007,68(6):1090-1097
Two independent parallel trickling bed air biofilters (TBABs) ("A" and "B") with two different typical VOC mixtures were investigated. Toluene, styrene, methyl ethyl ketone (MEK), and methyl isobutyl ketone (MIBK) were the target VOCs in the mixtures. Biofilter "A" was fed equal molar ratio of the VOCs and biofilter "B" was fed a mixture based on EPA 2003 emission report. Backwashing and substrate starvation operation were conducted as biomass control. Biofilter "A" and "B" maintained 99% overall removal efficiency for influent concentration up to 500 and 300 ppmv under backwashing operating condition, respectively. The starvation study indicated that it can be an effective biomass control for influent concentrations up to 250 ppmv for biofilter "A" and 300 ppmv for "B". Re-acclimation of biofilter performance was delayed with increase of influent concentration for both biofilters. Starvation operation helped the biofilter to recover at low concentrations and delayed re-acclimation at high concentrations. Furthermore, re-acclamation for biofilter "B" was delayed due to its high toluene content as compared to biofilter "A". The pseudo first-order removal rate constant decreased with increase of volumetric loading rate for both biofilters. MEK and MIBK were completely removed in the upper 3/8 media depth. While biofilter depth utilization for the removal of styrene and toluene increased with increase of influent concentrations for both biofilters. However, toluene removal utilized more biofilter depth for biofilter "B" as compared to biofilter "A".  相似文献   

4.
管式生物过滤器去除乙苯废气   总被引:1,自引:0,他引:1  
生物过滤由于其良好的成本效益和环境友好性已经成为控制挥发性有机化合物(VOCs)含量和气味气体排放的常规技术。营养物质的均匀分布、生物膜和介质床内的气体流是成就一个性能优良的生物过滤器至关重要的因素。而由本实验室开发的管式生物过滤器(TBFs)已被证明具备此优势。本实验的管式生物过滤器以聚氨酯海绵作为填料,研究在不同有机负荷、气体停留时间(EBCT)、进气量和表面活性剂等条件下乙苯废气的去除效率(RE)。实验同时记录了管式生物过滤器启动阶段的表现。初期使附着在填料上的微生物暴露在浓度为40 mg/m3的乙苯废气中40 d,此时的气体停留时间为15 s,使微生物慢慢适应并逐步降解乙苯废气;然后连续地控制管式生物过滤器的入口乙苯浓度为40、80、120和160 mg/m3,以使有机负荷逐步升高。结果表明,乙苯去除效率随着有机负荷的增大而逐步减小。当气体停留时间从15 s增加到30 s和60 s,而有机负荷控制在38.60 g/(m3·h)时,乙苯废气去除效率略微增加。此外,随着进气量的增大乙苯废气的最大平均去除效率有所下降而此时的降解容量增大,这个过程中乙苯进气浓度保持不变。结果还表明,在营养液中加入聚乙二醇辛基苯基醚这种表面活性剂可以提高乙苯废气的去除效率。  相似文献   

5.
The main research objective of this study is to enhance the removal of recalcitrant compounds that are not readily bioavailable due to limiting mass transfer rate between the liquid and gas phases. Four trickle-bed air biofilters (TBABs), loaded with pelletized diatomaceous earth support media, were run at an empty bed residence time (EBRT) of 120 sec. After an acclimation period at constant loading rate (LR) of n-hexane (13.2 g m?3 hr?1) and intermittent feeding of methanol, n-hexane influent LR was then increased in step-wise fashion to 47.7 g m?3 hr?1 for biofilters receiving acidic nutrients (pH 4), and to 36.3 g m?3 hr?1 for biofilters receiving nutrient at pH 7. The results have shown that for TBABs receiving nutrient at pH 4, greater elimination capacities were obtained as compared to TBABs working at pH 7. n-Hexane removal efficiency of more than 84% at LR up to 47.7 g m?3 hr?1 was obtained for pH 4 nutrient-fed biofilters, while for biofilters with nutrients fed at pH 7, the removal efficiency did not exceed 64% for n-hexane LR of 36.3 g m?3 hr?1. The microbial analysis revealed that no fungal community was detected in TBABs run at neutral pH. The fungi communities that were initially acclimating TBABs run at pH 4, namely, Aspergillus niger and Fusarium solani, were not detected at the end of the experiment, while Gibberella moniliformis (Fusarium verticillioides) genus became the dominant species. Gibberella moniliformis (Fusarium verticillioides) was present along all the biofilter media and sustained very high n-hexane elimination at steady-state condition.
Implications:With growing apprehension about sustainability and environmental protection, with limited resources available, and with the passage of the 1990 Amendments to the Clean Air Act, there is more need for using air pollution control techniques that are sound economically and proven environmentally friendly. Biofiltration systems, namely, trickle-bed air biofilters, were for decades recognized as efficient in treating air pollutants. Thus, the application of this technique over a wide industrial spectrum would certainly contribute to reduction of hazardous gas emissions.  相似文献   

6.
Abstract

Biofiltration is an economical air pollution control (APC) technology, particularly suitable for the treatment of air-streams having high flow rates and low concentrations of volatile organic compounds (VOCs). This technology utilizes enzymatic catalysis at ambient conditions to mineralize such pollutants to CO2, H2O, and salts. A pilot-scale study conducted for more than 4 years investigated the development of a new biofiltration technology employing trickle bed air biofilters (TBABs). Following the completion of this experimental study, additional data analysis was performed to develop a simple lumped-parameter biofilter model, assuming first-order kinetics. This model related the observed biofilter performance to the principle independent physical, thermodynamic, and biochemical parameters. The initial model has subsequently been expanded to incorporate Monod kinetics. In this paper, the development and use of the final explicit lumped-parameter biofilter model and design equation, incorporating Monod kinetics, are presented. To facilitate the application of this model, practical procedures are also presented for the determination of VOC solubility, VOC biokinetic Monod parameters, and the maximum practical biofilter inlet VOC concentration.  相似文献   

7.
ABSTRACT

Trickle-bed air biofilters (TBABs) are suitable for treatment of hydrophilic volatile organic compounds, but they pose a challenge for hydrophobic compounds. Three laboratory-scale TBABs were used for the treatment of an airstream contaminated with different ratios of n-hexane and benzene mixtures. The ratios studied were 1:1, 2:1, and 1:3 n-hexane:benzene by volume. Each TBAB was operated at a pH of 4 and a temperature of 20 °C. The use of acidic-buffered nutrient solution was targeted for changing the microorganism consortium to fungi as the main biodegradation element. The experimental plan was designed to investigate the long-term performance of the TBABs with an emphasis on different mixture loading rates, removal efficiency with TBAB depth, volatile suspended solids, and carbon mass balance closure. n-Hexane loading rate was kept constant in the TBABs for comparison reasons and ranged from 4 to 22 g/(m3.hr). Corresponding benzene loadings ranged from 4 to 43 g/(m3.hr). Generally, benzene behavior in the TBAB was superior to that of n-hexane because of its higher solubility. n-Hexane showed improved performance in the 2:1 mixing ratio as compared with the other two ratios.

IMPLICATIONS The use of biofilters is a cheap and attractive option; however, their application is limited because of several challenges. One of them is the reluctance of hydrophobic compounds for biodegradation and the coexistence of other compounds in air emissions. This paper evaluated the impact of different mixing ratios of two hydrophobic compounds and the effect of increasing influent concentration. Finally, a comparison is provided on the best performance attained for these hydrophobic compounds as single solutes. The results of this study will aid in the design and operation of full-scale biofilters.  相似文献   

8.
Biofiltration is an economical air pollution control (APC) technology, particularly suitable for the treatment of air-streams having high flow rates and low concentrations of volatile organic compounds (VOCs). This technology utilizes enzymatic catalysis at ambient conditions to mineralize such pollutants to CO2, H2O, and salts. A pilot-scale study conducted for more than 4 years investigated the development of a new biofiltration technology employing trickle bed air biofilters (TBABs). Following the completion of this experimental study, additional data analysis was performed to develop a simple lumped-parameter biofilter model, assuming first-order kinetics. This model related the observed biofilter performance to the principle independent physical, thermodynamic, and biochemical parameters. The initial model has subsequently been expanded to incorporate Monod kinetics. In this paper, the development and use of the final explicit lumped-parameter biofilter model and design equation, incorporating Monod kinetics, are presented. To facilitate the application of this model, practical procedures are also presented for the determination of VOC solubility, VOC biokinetic Monod parameters, and the maximum practical biofilter inlet VOC concentration.  相似文献   

9.
ABSTRACT

This study utilized a biotrickling filter with blast-furnace slag packings (sizes = 20-40 mm; specific surface area = 120 m2/m3) to treat toluene in an air stream. Also studied were the effects of volumetric loading (L), nutrient addition, and superficial gas velocity (Ug) or gas retention time on toluene elimination capacity. Experimental results indicate that, for a test period of 121 days, with no excess biomass removal, toluene removal efficiencies of over 90% were obtained with Ug < 80 m/hr and L < 30 g/m3.hr. For a test period of 49 days, with Ug < 80 m/hr and L increased from 1.2 to 81 g/m3.hr, the absence of nutrient supplementation did not limit the toluene elimination capacity. Nutrients stored in the biofilm could adequately support the microbial activity for the toluene elimination. According to data regression, a simplified mass-transfer model is proposed, which correlates the contaminant concentration with the packing height or gas empty bed retention time. As verified, the model proposed herein can be applied to cases involving low influent contaminant concentrations or loadings to the extent that none or only a trace amount of the contaminant can be found in the recirculation liquid. Although small media with larger specific surface areas can achieve a better mass transfer, the problems of frequent backwashing and relatively greater gas resistance in using this type of media probably outweigh the advantages, particularly for full-scale systems that would not be watched as closely as laboratory test systems.  相似文献   

10.
Modeling variations of medium porosity in rotating drum biofilter   总被引:1,自引:0,他引:1  
Yang C  Chen H  Zeng G  Yu G  Liu X  Zhang X 《Chemosphere》2009,74(2):245-249
Rotating drum biofilters (RDBs) mounted with reticulated polyurethane sponge media has showed high removal efficiencies over a long period of time when used for volatile organic compound (VOC) removal. Due to the accumulation of biomass within the sponge medium, the porosity of a filter bed usually changes dynamically, which makes it difficult to predict and to control. In this paper, the porosity of a multi-layer RDB bed was investigated by a diffusion-reaction model in which biofilm growth and decay were taken into account at the pore scale of the sponge medium. Temporal and spatial changes of porosity were studied under various organic loadings and gas empty bed contact times (EBCTs). The porosity of the biofilter bed was assumed to be a function of biofilm thickness, and all the pores were assumed to be uniform. Toluene was selected as the model VOC. The model was solved using numerical methods through the MATLAB software. Results show that the porosity decreased with increased time of operation, increased toluene loading, or decreased gas EBCT value. The porosity in the outermost medium layer was less than that in the inner medium layers. Toluene removal efficiencies and porosities calculated from this model correlated with the experimental data well. Porosity variation was proposed to be an indicator for prediction of biofilter performance in biofilters as a consequence.  相似文献   

11.
Abstract

Butanol, ether, toluene, and hexane, which have Henry's constants ranging from 0.0005 to 53, were used to investigate the effects of substrate solubility or availability on the removal of volatile organic compounds (VOCs) in trickle-bed biofilters. Results from this study suggest that, although removal of a VOC generally increases with a decrease in its Henry's constant, an optimal Henry's constant range for biofiltration may exist. For the treatment of VOCs with high Henry's constant values, such as hexane and toluene, the transfer of VOCs between the vapor and liquid phases or between the vapor phase and the biofilm is a rate-determining step. However, oxygen (O2) transfer may become a rate-limiting step in treating VOCs with low Henry's constants, such as butanol, especially at high organic loadings. The results demonstrated that in a gas-phase aerobic biofilter, nitrate can serve both as a growth-controlling nutrient and as an electron acceptor in a biofilm for the respiration of VOCs with low Henry's constants. Microbial communities within the biofilters were examined using denaturing gradient gel electrophoresis to provide a more complete picture of the effect of O2 limitation and denitrification on biofilter performance.  相似文献   

12.
Biofiltration of high loads of ethyl acetate in the presence of toluene.   总被引:1,自引:0,他引:1  
To date, biofilters have been used primarily to control dilute, usually odorous, off-gases with relatively low volatile organic compound (VOC) concentrations (< 1 g m-3) and VOC loads (< 50 g m-3 hr-1). Recently, however, U.S. industry has shown an interest in applying biofilters to higher concentrations of VOCs and hazardous air pollutants (HAPs). In this study, the behavior of biofilters under high loads of binary VOC mixtures was studied. Two bench-scale biofilters were operated using a commercially available medium and a mixture of wood chips and compost. Both were exposed to varying mixtures of ethyl acetate and toluene. Concentration profiles and the corresponding removal efficiencies as a function of VOC loading were determined through frequent grab-sampling and GC analysis. Biofilter response to two frequently encountered operating problems--media dry-out and operating temperatures exceeding 40 degrees C--was also evaluated under controlled conditions. Microbial populations were also monitored to confirm the presence of organisms capable of degrading both major off-gas constituents. The results demonstrated several characteristics of biofilters operating under high VOC load conditions. Maximum elimination capacities for ethyl acetate were typically in the range of 200 g m-3 hr-1. Despite the presence of toluene degraders, the removal of toluene was inhibited by high loads of ethyl acetate. Several byproducts, particularly ethanol, were formed. Short-term dry-out and temperature excursions resulted in reduced performance.  相似文献   

13.
Abstract

Two biofilters were operated to treat a waste gas stream intended to simulate off-gases generated during the manufacture of reformulated paint. The model waste gas stream consisted of a five-component solvent mixture containing acetone (450 ppmv), methyl ethyl ketone (12 ppmv), toluene (29 ppmv), ethylbenzene (10 ppmv), and p-xylene (10 ppmv). The two biofilters, identical in construction and packed with a polyurethane foam support medium, were inoculated with an enrichment culture derived from compost and then subjected to different loading conditions during the startup phase of operation. One biofilter was subjected to intermittent loading conditions with contaminants supplied only 8 hr/day to simulate loading conditions expected at facilities where manufacturing operations are discontinuous. The other biofilter was subjected to continuous contaminant loading during the initial start period, and then was switched to intermittent loading conditions. Experimental results demonstrate that both startup strategies can ultimately achieve high contaminant removal efficiency (>99%) at a target contaminant mass loading rate of 80.3 g m?3 hr?1 and an empty bed residence time of 59 sec. The biofilter subjected to intermittent loading conditions at startup, however, took considerably longer to reach high performance. In both biofilters, ketone components (acetone and methyl ethyl ketone) were more rapidly degraded than aromatic hydrocarbons (toluene, ethylbenzene, and p-xylene). Scanning electron microscopy and plate count data revealed that fungi, as well as bacteria, populated the biofilters.  相似文献   

14.
ABSTRACT

A pilot apparatus of a regenerative catalytic oxidizer (RCO) equipped with two electrical heaters and two 20-cm i.d. × 200-cm height regenerative beds was used to treat methyl ethyl ketone (MEK) and toluene, respectively, in an airstream. The regenerative beds were packed with gravel (approximate particle size 1.25 cm, specific area 205 m2/m3, and specific heat capacity 840 J/kg °C) as a solid regenerative material and K-type thermal couples for measuring solid and gas temperatures, respectively. The catalyst bed temperature was kept around 400 °C and the gas superficial velocity was operated at 0.234 m/sec. This investigation measured and analyzed distributions of solid and gas temperatures with operating time and variations of volatile organic compound (VOC) concentrations in the regenerative beds. The overall VOC removal efficiency exceeded 98% for MEK and 95% for toluene. Degradation of VOCs will exist for MEK on the surface of solid material (gravel) in the temperature range of 330-400 °C, but toluene does not exhibit this phenomenon.  相似文献   

15.
The characteristics and concentrations of volatile organic compounds (VOCs) in the roadside microenvironments of metropolitan Hong Kong were investigated. The VOC concentrations, especially toluene, benzene and chlorinated VOCs in Hong Kong were high when compared with those in most developed cities. The average and maximum concentration of toluene was 74.9 and 320.0 μg m−3, respectively. The respective values for benzene were 25.9 and 128.6 μg m−3. The chlorinated VOCs were dominated by trichloroethylene and tetrachloroethylene. The maximum concentrations of these two species reached 248.2 and 144.0 μg m−3, respectively. There were strong variations in the spatial fluctuation and characteristic of VOC concentrations. The highest VOC concentrations were found in the industrial district, which were followed by those in the commercial district, the central business district and finally the residential district. The highest concentrations of most VOC species, especially chlorinated VOC were found in the industrial and commercial districts. The average benzene/toluene ratio in Hong Kong was 0.5 suggesting that vehicular emission was the dominant VOC source in most areas of Hong Kong. There were strong deviations in benzene/toluene, benzene/ethylbenzene and benzene/(m+p-xylene) ratios in the commercial district, and highly chlorinated VOC in the industrial and commercial districts. These suggest that there were other benzene and VOC sources overlying on the high background VOC concentrations in these districts. The common usage of organic solvents in the building and construction industries, and in the small industries in the industrial and commercial districts were believed to be important sources of VOC in Hong Kong.  相似文献   

16.
Effect of substrate Henry's constant on biofilter performance   总被引:4,自引:0,他引:4  
Butanol, ether, toluene, and hexane, which have Henry's constants ranging from 0.0005 to 53, were used to investigate the effects of substrate solubility or availability on the removal of volatile organic compounds (VOCs) in trickle-bed biofilters. Results from this study suggest that, although removal of a VOC generally increases with a decrease in its Henry's constant, an optimal Henry's constant range for biofiltration may exist. For the treatment of VOCs with high Henry's constant values, such as hexane and toluene, the transfer of VOCs between the vapor and liquid phases or between the vapor phase and the biofilm is a rate-determining step. However, oxygen (O2) transfer may become a rate-limiting step in treating VOCs with low Henry's constants, such as butanol, especially at high organic loadings. The results demonstrated that in a gas-phase aerobic biofilter, nitrate can serve both as a growth-controlling nutrient and as an electron acceptor in a biofilm for the respiration of VOCs with low Henry's constants. Microbial communities within the biofilters were examined using denaturing gradient gel electrophoresis to provide a more complete picture of the effect of O2 limitation and denitrification on biofilter performance.  相似文献   

17.
This study examined student’s exposure to volatile organic compounds (VOCs) while commuting by bus and motorcycle in Taipei, Taiwan in the winter of 1992. A total of 19 target G5-C10 VOCs on three most frequently used commuting routes were collected on Tenax-GC adsorbent tubes. The VOCs were desorbed by thermal desorption method and analyzed by GCMS. The most abundant VOC exposure experienced by commuters was to toluene. Several alkylated benzenes, such as propyl benzenes, ethyl-methyl-benzenes and trimethyl-benzenes, were relatively abundant on the roads in Taipei. The mean benzene concentration measured in buses was 173 µg/m3 and 379.7 µg/m3 on motorcycles. On the average, the commuters in Taipei experienced about three to eight times higher VOC concentrations than the commuters in Los Angeles, California. Higher VOC concentrations were measured on motorcycles than in buses. The VOC concentrations were not significantly different between morning and afternoon commutes, nor among the three commuting routes. VOC concentrations measured in classrooms at three schools in downtown Taipei did not vary significantly on each sampling day. However, at each school the in-classroom VOC concentrations varied significantly over the six consecutive sampling days. The VOC concentrations measured on the roads were about five times higher than those measured in the school classrooms in the city. Moderate to high correlations were found among most of the measurements of the 19 VOCs. The survey questionnaire indicated that daily commuting time ranged from 45 minutes for elementary school students to 95 minutes for vocational school students. The projected upper-bound cancer risks associated with student’s exposure to benzene ranged from 7.5 x 10-3 to 1.8 x 10-5 during their commutes in Taipei.  相似文献   

18.
Excessive accumulation of biomass within gas-phase biofilters often results in the deterioration of removal performance. Compared with chemical and biological technologies, physical technologies are more effective in removing biomass and inducing less inhibition of the biofilter performance. This study applied different physical technologies, namely, air sparging, mechanical mixing, and washing with water at various temperatures, to remove excess biomass in biofilters treating toluene. Filter pressure drop, removed dry biomass, biofilter performance, and microbial metabolic characteristics were analyzed to evaluate the effectiveness of the methods. Results showed that air sparging was inefficient for biomass removal (1 kg dry biomass/m3 filter), whereas mechanical mixing significantly inhibited removal efficiencies (<30%). Washing of the packing with fluids was feasible, and hot fluids can remove a large amount of biomass. However, hot fluids reduce microbial activity and inhibit removal performance. Washing of the packing with either 20°C or 50°C water showed efficiency as >3 kg dry biomass/m3 filter can be removed at both temperatures with removal efficiencies at approximately 40% after treatment. Finally, different technologies were compared and summarized to propose an optimized strategy of biomass control for industrial biofilters.

Implications: This study is to apply different physical technologies, namely, air sparging, mechanical mixing, and washing with water of different temperatures, to remove the excess biomass in biofilters treating toluene. The filter pressure drop, removed dry biomass, biofilter performance, and microbial metabolic characteristics were all analyzed to evaluate the effectiveness of the methods. The results of this study provide useful information regarding biomass control of industrial biofilters.  相似文献   


19.
Methane (CH4) removal in the presence of ethanol vapors was performed by a stone-based bed and a hybrid packing biofilter in parallel. In the absence of ethanol, a methane removal efficiency of 55 ± 1% was obtained for both biofilters under similar CH4 inlet load (IL) of 13 ± 0.5 gCH4 m?3 h?1 and an empty bed residence time (EBRT) of 6 min. The results proved the key role of the bottom section in both biofilters for simultaneous removal of CH4 and ethanol. Ethanol vapor was completely eliminated in the bottom sections for an ethanol IL variation between 1 and 11 gethanol m?3 h?1. Ethanol absorption and accumulation in the biofilm phase as well as ethanol conversion to CO2 contributed to ethanol removal efficiency of 100%. In the presence of ethanol vapor, CO2 productions in the bottom section increased almost fourfold in both biofilters. The ethanol concentration in the leachate of the biofilter exceeding 2200 gethanol m?3 leachate in both biofilters demonstrated the excess accumulation of ethanol in the biofilm phase. The biofilters responded quickly to an ethanol shock load followed by a starvation with 20% decrease of their performance. The return to normal operations in both biofilters after the transient conditions took less than 5 days. Unlike the hybrid packing biofilter, excess pressure drop (up to 1.9 cmH2O m?1) was an important concern for the stone bed biofilter. The biomass accumulation in the bottom section of the stone bed biofilter contributed to 80% of the total pressure drop. However, the 14-day starvation reduced the pressure drop to 0.25 cmH2O m?1.  相似文献   

20.
Because of the characteristics of low operating cost and convenient operation, the biotrickling filter is extensively researched and used to treat low concentration waste gas contaminated by volatile organic compounds (VOCs) and other odors. In this paper, two laboratory-scale biotrickling filters were constructed and toluene was selected as the sole carbon source, and the effects of different waste-gas flow configuration patterns on the purification capacity and the microbial community functional diversity of biotrickling filters were evaluated. The results indicated that the flow-directional-switching (FDS) biotrickling filter had better purification performance, and the maximum elimination capacity reached 480 g·m?3·hr?1, which was 17.1% higher than conventional unidirectional-flow (UF) biotrickling filter. Comparing the purification capacities of different sections in two biotrickling filters, the maximum toluene elimination capacity of section III in FDS system could reach 542 g·m?3·hr?1, which was 2.8 times as great as that in UF system, which resulted from the difference of elimination capacity in two systems. By analyzing the metabolic activity of two systems by community-level physiological profiling (CLPP) with Biolog (Biolog Inc., Hayward, CA) ECO-plate technique, metabolic activity in three sections of FDS system was higher than that of UF system. The metabolic activity was the highest in section III of FDS system and 46.8% higher than that of UF system. Shannon index and McIntosh index of section III in FDS system were 6.2% and 31.5% higher, respectively, than those of UF system.

Implications: The flow-directional-switching (FDS) biotrickling filter had a better purification performance than unidirectional-flow (UF) biotrickling filter at high inlet loadings, because FDS produced a more uniform distribution of biomass and microbial metabolic capacity along the length of the packed bed without diminishing activity and removal capacity in the inlet section.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号