首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Linear, quadratic, and artificial neural network (ANN)-based metamodels were developed for predicting the extent of anthrax spore inactivation by chlorine dioxide in a ventilated three-dimensional space over time from computational fluid dynamics model (CFD) simulation data. Dimensionless groups were developed to define the design space of the problem scenario. The Hammersley sequence sampling (HSS) method was used to determine the sampling points for the numerical experiments within the design space. A CFD model, comprised of multiple submodels, was applied to conduct the numerical experiments. Large eddy simulation (LES) with the Smagorinsky subgridscale model was applied to compute the airflow. Anthrax spores were modeled as a dispersed solid phase using the Lagrangian treatment. The disinfectant transport was calculated by solving a mass transport equation. Kinetic decay constants were included for spontaneous decay of the disinfectant and for the reaction of the disinfectant with the surfaces of the three-dimensional space. To enhance the mixing of the disinfectant with the room air, a momentum source was included in the simulation. An inactivation rate equation accounted for the reaction between the spores and the disinfectant. The ANN-based metamodels were most successful in predicting the number of viable bioaerosols remaining in an arbitrary enclosed space. Sensitivity analysis showed that the mass fraction of the disinfectant, inactivation rate constant, and contact time had the most influence on the inactivation of the spores.  相似文献   

2.
The efficacy of disinfection processes in water purification systems is governed by several key factors, including reactor hydraulics, disinfectant chemistry, and microbial inactivation kinetics. The objective of this work was to develop a computational fluid dynamics (CFD) model to predict velocity fields, mass transport, chlorine decay, and microbial inactivation in a continuous flow reactor. The CFD model was also used to evaluate disinfection efficiency in alternative reactor designs. The CFD reactor analysis demonstrates that disinfection efficiency is affected by both kinetics and mixing state (i.e., degree of micromixing or segregation). Residence time distributions (RTDs) derived from tracer analysis do not describe intrinsic mixing conditions. The CFD-based disinfection models account for reactor mixing patterns by resolution of the reactor velocity field and thus provide a better prediction of microbial inactivation than models that use an RTD.  相似文献   

3.
The effectiveness of gaseous ozone (O3) as a disinfectant was tested on Bacillus subtilis spores, which share the same physiological characteristics as Bacillus anthracis spores that cause the anthrax disease. Spores dried on surfaces of different carrier material were exposed to O3 gas in the range of 500-5000 ppm and at relative humidity (RH) of 70-95%. Gaseous O3 was found to be very effective against the B. subtilis spores, and at O3 concentrations as low as 3 mg/L (1500 ppm), approximately 3-log inactivation was obtained within 4 hr of exposure. The inactivation curves consisted of a short lag phase followed by an exponential decrease in the number of surviving spores. Prehydration of the bacterial spores has eliminated the initial lag phase. The inactivation rate increased with increasing O3 concentration but not >3 mg/L. The inactivation rate also increased with increase in RH. Different survival curves were obtained for various surfaces used to carry spores. Inactivation rates of spores on glass, a vinyl floor tile, and office paper were nearly the same. Whereas cut pile carpet and hardwood flooring surfaces resulted in much lower inactivation rates, another type of carpet (loop pile) showed significant enhancement in the inactivation of the spores.  相似文献   

4.
Bacillus subtilis subsp. niger spores are a commonly used biological indicator to evaluate the disinfection of an enclosed space. In the present study, chlorine dioxide (ClO2) gas was applied to inactivate B. subtilis subsp. niger spores in an enclosed space. The effects of the ClO2 gas concentration (1-3 mg/l), relative humidity (RH, 30-70%) and exposure time (30-90 min) were investigated using a response surface methodology (RSM). A three-factor Box-Behnken experimental design was used. The obtained data were adequately fitted to a second-order polynomial model with an R2adj of 0.992. The ClO2 gas concentration, RH and exposure time all significantly (P<0.05) and positively correlated with the inactivation of B. subtilis subsp. niger spores. The interaction between the ClO2 gas concentration and RH as well as that between the exposure time and RH indicated significant and synergistic effects (P<0.05). The predictive model was validated by additional eight experiments and proven to be with good accuracy. Overall, this model established by the RSM could show the trend of the inactivation of spores, indicate the interactions between important factors, and provide a reference to determine effective conditions for the disinfection in different enclosed spaces by ClO2 gas.

Implications: The inactivation of indoor biological contaminants plays an important role in preventing the transmission of pathogens and ensuring human safety. The predictive model using response surface methodology indicates the influence and interaction of the main factors on the inactivation of Bacillus subtilis subsp. niger spores by ClO2 gas, and can predict a ClO2 gas treatment condition to achieve an effective sterilization of enclosed spaces. The results in this paper will provide a reference for the application of ClO2 gas treatments for indoor disinfection.  相似文献   


5.
Abstract

Computational fluid dynamic (CFD) analysis of the thermal flow in the combustion chamber of a solid waste incinerator provides crucial insight into the incinerator’s performance. However, the interrelation of the gas flow with the burning waste has not been adequately treated in many CFD models. A strategy for a combined simulation of the waste combustion and the gas flow in the furnace is introduced here. When coupled with CFD, a model of the waste combustion in the bed provides the inlet conditions for the gas flow field and receives the radiative heat flux onto the bed from the furnace wall and gaseous species. An unsteady one-dimensional bed model was used for the test simulation, in which the moving bed was treated as a packed bed of homogeneous fuel particles. The simulation results show the physical processes of the waste combustion and its interaction with the gas flow for various operational parameters.  相似文献   

6.
The paper summarizes the results of a bench-scale study to evaluate the feasibility of using peracetic acid (PAA) as a substitute for sodium hypochlorite both for discharge into surface water and for agricultural reuse. Trials were carried out with increasing doses (1, 2, 3, 5, 10, and 15 mg/L) and contact times (6, 12, 18, 36, 42, and 54 minutes) to study disinfectant decay and bacterial removal and regrowth, using fecal coliform and Escherichia coli (E. coli) as process efficiency indicators. Peracetic acid decay kinetics was evaluated in tap water and wastewater; in both cases, PAA decays according to first-order kinetics with respect to time, and a correlation was found between PAA oxidative initial consumption and wastewater characteristics. The PAA disinfection efficiency was correlated with operating parameters (active concentration and contact time), testing different kinetic models. Two data groups displaying a different behavior on the basis of initial active concentration ranges (1 to 2 mg/L and 5 to 15 mg/L, respectively) can be outlined. Both groups had a "tailing-off" inactivation curve with respect to time, but the second one showed a greater inactivation rate. Moreover, the effect of contact time was greater at the lower doses. Hom's model, used separately for the two data groups, was found to best fit experimental data, and the disinfectant active concentration appears to be the main factor affecting log-survival ratios. Moreover, the S-model better explains the initial resistance of E. coli, especially at low active concentrations (< 2 mg/L) and short contact times (< 12 minutes). Microbial counts, performed by both traditional methods and flow cytometry, immediately and 5 hours after sample collection (both with or without residual PAA inactivation), showed that no appreciable regrowth took place after 5 hours, neither for coliform group bacteria, nor for total heterotrophic bacteria.  相似文献   

7.
The main objective of this study is to apply neutral electrolyzed water (NEW) spraying to inactivate bioaerosols. We evaluated the inactivation efficiency of NEW applied to inactivate two airborne bacterial Escherichia coli and Bacillus subtilis aerosols inside an environmental-controlled chamber in the study. Generated with electrolyzing 6.15 M sodium chloride brine, the NEW with free available chlorine (FAC) concentration 50, 100, and 200 ppm was pumped with an air pressure of 70 kg/cm2 through nozzle into the chamber to inactive E. coli and B. subtilis aerosols precontaminated air (initial counts of 3?×?104 colony-forming units [CFU]/m3). Bacterial aerosols were collected and cultured from chamber before and after NEW spray. The air exchange rate (ACH, hr?1) of the chamber was set to simulate fresh air ventilating dilution of indoor environment. First-order concentration decaying coefficients (Ka, min?1) of both bacterial aerosols were measured as an index of NEW inactivation efficiency. The result shows that higher FAC concentration of NEW spray caused better inactivation efficiency. The Ka values under ACH 1.0 hr?1 were 0.537 and 0.598 for E. coli of FAC 50 and 100 ppm spraying, respectively. The Ka values of FAC 100 ppm and 200 ppm spraying for B. subtilis were 0.063 and 0.085 under ACH 1.0 hr?1, respectively. The results indicated that NEW spray is likely to be effective in inactivation of bacterial airborne contamination. Moreover, it is observed in the study that the increase of ventilation rate and the use of a larger orifice-size nozzle may facilitate the inactivation efficiency.

Implications: Bacterial aerosols have been implicated in deterioration of air quality and occupational health. Effective, safe, and economic control technology is highly demanded, especially for agricultural and food industries. In the study, NEW mist spraying performed effectively in controlling E. coli and B. subtilis modeling bioaerosols contamination. The NEW revealed its potential as an alternative airborne disinfectant worth being discovered for improving the environmental quality in the future.  相似文献   

8.
A computational fluid dynamics (CFD) methodology for simulating the combustion process has been validated with experimental results. Three different types of experimental setups were used to validate the CFD model. These setups include an industrial-scale flare setups and two lab-scale flames. The CFD study also involved three different fuels: C3H6/CH4/Air/N2, C2H4/O2/Ar, and CH4/Air. In the first setup, flare efficiency data from the Texas Commission on Environmental Quality (TCEQ) 2010 field tests were used to validate the CFD model. In the second setup, a McKenna burner with flat flames was simulated. Temperature and mass fractions of important species were compared with the experimental data. Finally, results of an experimental study done at Sandia National Laboratories to generate a lifted jet flame were used for the purpose of validation. The reduced 50 species mechanism, LU 1.1, the realizable k-? turbulence model, and the EDC turbulence–chemistry interaction model were used for this work. Flare efficiency, axial profiles of temperature, and mass fractions of various intermediate species obtained in the simulation were compared with experimental data and a good agreement between the profiles was clearly observed. In particular, the simulation match with the TCEQ 2010 flare tests has been significantly improved (within 5% of the data) compared to the results reported by Singh et al. in 2012. Validation of the speciated flat flame data supports the view that flares can be a primary source of formaldehyde emission.
ImplicationsValidated computational fluid dynamics (CFD) models can be a useful tool to predict destruction and removal efficiency (DRE) and combustion efficiency (CE) under steam/air assist conditions in the face of many other flare operating variables such as fuel composition, exit jet velocity, and crosswind. Augmented with rigorous combustion chemistry, CFD is also a powerful tool to predict flare emissions such as formaldehyde. In fact, this study implicates flares emissions as a primary source of formaldehyde emissions. The rigorous CFD simulations, together with available controlled flare test data, can be fitted into simple response surface models for quick engineering use.  相似文献   

9.
ABSTRACT

Vitrification demonstrations were conducted for surrogates of three inorganic wastewater sludges in a high-temperature, refractory-lined, slurry-fed melter. The total par-ticulate concentrations and melter decontamination factors were determined for selected elements. The decontamination factors were less than 10 for cadmium and lead in all three demonstrations. The decontamination factors for chromium were less than 30 in the two demonstrations using refractories containing chromium, and they were greater than 150 for the demonstrations using refractories without chromium. Except for one demonstration on a surrogate waste with a high sulfate content, decontamination factors were above 80 for the other heavy metals in the demonstrations.  相似文献   

10.
以枯草芽孢杆菌芽孢为模型微生物,研究了实际水体中单独氯消毒、单独臭氧消毒和臭氧-自由氯联合作用的灭菌效果.结果表明,枯草芽孢杆菌芽孢对单独氯消毒的抗性很大,6 mg/L氯作用240 min后灭活率仅为0.84个对数级;臭氧对枯草芽孢杆菌芽孢有较好的灭活效果,臭氧作用5 min,对其有4.68个对数级的灭活率.与单独氯消...  相似文献   

11.
The Bio-response Operational Testing and Evaluation (BOTE) Project was a cross-government effort designed to operationally test and evaluate a response to a biological incident (release of Bacillus anthracis [Ba] spores, the causative agent for anthrax) from initial public health and law enforcement response through environmental remediation. The BOTE Project was designed to address site remediation after the release of a Ba simulant, Bacillus atrophaeus spp. globigii (Bg), within a facility, drawing upon recent advances in the biological sampling and decontamination areas. A key component of response to a biological contamination incident is the proper management of wastes and residues, which is woven throughout all response activities. Waste is generated throughout the response and includes items like sampling media packaging materials, discarded personal protective equipment, items removed from the facility either prior to or following decontamination, aqueous waste streams, and materials generated through the application of decontamination technologies. The amount of residual contaminating agent will impact the available disposal pathways and waste management costs. Waste management is an integral part of the decontamination process and should be included through “Pre-Incident” response planning. Overall, the pH-adjusted bleach decontamination process generated the most waste from the decontamination efforts, and fumigation with chlorine dioxide generated the least waste. A majority of the solid waste generated during pH-adjusted bleach decontamination was the nonporous surfaces that were removed, bagged, decontaminated ex situ, and treated as waste. The waste during the two fumigation rounds of the BOTE Project was associated mainly with sampling activities. Waste management activities may represent a significant contribution to the overall cost of the response/recovery operation. This paper addresses the waste management activities for the BOTE field test.Implications: Management of waste is a critical element of activities dealing with remediation of buildings and outdoor areas following a biological contamination incident. Waste management must be integrated into the overall remediation process, along with sampling, decontamination, resource management, and other important response elements, rather than being a stand-alone activity. The results presented in this paper will provide decision makers and emergency planners at the federal/state/tribal/local level information that can be used to integrate waste management into an overall systems approach to planning and response activities.  相似文献   

12.
To achieve the hygienic safety of food waste used as animal feed, a hydrothermal treatment process of 60–110 °C for 10–60 min was applied on the separated food waste from a university canteen. Based on the microbial analysis of raw waste, the inactivation of hygienic indicators of Staphylococcus aureus (SA), total coliform (TC), total aerobic plate counts (TPC), and molds and yeast (MY) were analyzed during the hydrothermal process. Results showed that indicators' concentrations were substantially reduced after hydrothermal treatment, with a greater reduction observed when the waste was treated with a higher temperature and pressure and a longer ramping time. The 110 °C hydrothermal treatment for 60 min was sufficient to disinfect food waste as animal feed from the viewpoint of hygienic safety. Results obtained so far indicate that hydrothermal treatment can significantly decrease microbial indicators' concentrations but does not lead to complete sterilization, because MY survived even after 60 min treatment at 110 °C. The information from the present study will contribute to the microbial risk control of food waste–amended animal feed, to cope with legislation on food or feed safety.

Implications: Reduction of microbial indicators at ramping time and holding time during the hydrothermal process showed that hydrothermal treatment is an effective method to achieve hygienic feed from food waste to a certain extent, but the conditions researched in this study were not enough for the complete sterilization of food waste, because of the different heat resistance of bacteria and spores.  相似文献   

13.
With its potential for low (if any) disinfection byproduct formation and easy retrofit for chlorine contactors, peracetic acid (PAA) or use of PAA in combination with other disinfectant technologies may be an attractive alternative to chlorine-based disinfection. Examples of systems that might benefit from use of PAA are water reuse schemes or plants discharging to sensitive receiving water bodies. Though PAA is in use in numerous wastewater treatment plants in Europe, its chemical kinetics, microbial inactivation rates, and mode of action against microorganisms are not thoroughly understood. This paper presents results from experimental studies of PAA demand, PAA decay, and microbial inactivation, with a complementary modeling analysis. Model results are used to evaluate techniques for measurement of PAA concentration and to develop hypotheses regarding the mode of action of PAA in bacterial inactivation. Kinetic and microbial inactivation rate data were collected for typical wastewaters and may be useful for engineers in evaluating whether to convert from chlorine to PAA disinfection.  相似文献   

14.
The use of gaseous ozone as a fungicide to preserve stored barley was studied. The effects of the following operating parameters on the fungicidal efficacy of ozone were examined: 1) the applied ozone dose, 2) ozonation time, 3) water activity of barley, and 4) temperature of barley. The effect of ozonation on germination of barley was also investigated. The experimental results showed that ozone was very effective in inactivation of fungi associated with the barley regardless of whether the fungi were in the forms of spores or mycelia. However, the mycelia were less resistant to ozone. With 5 minutes of ozonation, 96% of inactivation were achieved for spores as well as for mixtures of spores and small amount of mycelia by applying 0.16 and 0.10 mg of ozone/(g barley) x min, respectively. In addition, for sealed storage silos, inactivation of fungi continued when the ozone-containing gas was held inside the silos following a continuous ozone supply. The experimental results also revealed that increases in water activity and temperature of barley enhanced the fungicidal efficacy of ozone. Results of this study also indicated that the inactivation processes could be controlled by simply monitoring the exit ozone from the reactor instead of performing the time-consuming microbial examination. This finding would make the application of ozone in the preservation of cereal grains easier, simpler, and more practically applicable. The experimental results demonstrated that although ozonation above certain strength may reduce barley germination, inactivation of fungi was achieved with ozonation strengths far below the critical point.  相似文献   

15.
Reduction of viable airborne Staphylococcus epidermidis and Aspergillus niger spore concentrations using two types of photocatalytic fluorescent lamps under controlled environmental conditions (25 vs. 35 °C and 55 vs. 75% relative humidity) were investigated. Visible white-light and UVA black light were in-house spray-coated with TiO2 and then compared with a commercially coated visible white-light for microbial concentration reduction. The white-light photocatalytic lamps reduced the concentration of culturable S. epidermidis up to 92% independent of temperature or humidity change, while the black light photocatalytic lamps completely inactivated the culturable bacteria at 25 °C, 55% relative humidity. Humidity seemed to alleviate UVA damage since better bacteria survival was found. For A. niger spores, rising humidity or temperature could lower their concentration or drop their culturabilities so that a difference between the natural decay and photocatalytic disinfection could not be distinguished. Reductions of total bacteria and total fungi concentrations using these lamps were also examined under uncontrolled environmental conditions in an office and a waste-storage room. It was found that photocatalytic lamps could reduce total culturable bacteria concentration from 9 to 97% and total culturable fungi concentration from 3 to 95% within irradiation time of 30-480 min, respectively. Insignificant difference in concentration reduction among these photocatalytic lamps was pronounced.  相似文献   

16.
The release of Aspergillus versicolor, Cladosporium cladosporioides, and Penicillium melinii spores from agar and ceiling tile surfaces was tested under different controlled environmental conditions using a newly designed and constructed aerosolization chamber. This study revealed that all the investigated parameters, such as fungal species, air velocity above the surface, texture of the surface, and vibration of contaminated material, affected the fungal spore release. It was found that typical indoor air currents can release up to 200 spores cm−2 from surfaces with fungal spores during 30-min experiments. The release of fungal spores from smooth agar surfaces was found to be inadequate for accurately predicting the emission from rough ceiling tile surfaces because the air turbulence increases the spore release from a rough surface. A vibration at a frequency of 1 Hz at a power level of 14 W resulted in a significant increase in the spore release rate. The release appears to depend on the morphology of the fungal colonies grown on ceiling tile surfaces including the thickness of conidiophores, the length of spore chains, and the shape of spores. The spores were found to be released continuously during each 30-min experiment. However, the release rate was usually highest during the first few minutes of exposure to air currents and mechanical vibration. About 71–88% of the spores released during a 30-min interval became airborne during the first 10 min.  相似文献   

17.
Wastewater disinfection is practiced with the goal of reducing risks of human exposure to pathogenic microorganisms. In most circumstances, the efficacy of a wastewater disinfection process is regulated and monitored based on measurements of the responses of indicator bacteria. However, inactivation of indicator bacteria does not guarantee an acceptable degree of inactivation among other waterborne microorganisms (e.g., microbial pathogens). Undisinfected effluent samples from several municipal wastewater treatment facilities were collected for analysis. Facilities were selected to provide a broad spectrum of effluent quality, particularly as related to nitrogenous compounds. Samples were subjected to bench-scale chlorination and dechlorination and UV irradiation under conditions that allowed compliance with relevant discharge regulations and such that disinfectant exposures could be accurately quantified. Disinfected samples were subjected to a battery of assays to assess the immediate and long-term effects of wastewater disinfection on waterborne bacteria and viruses. In general, (viable) bacterial populations showed an immediate decline as a result of disinfectant exposure; however, incubation of disinfected samples under conditions that were designed to mimic the conditions in a receiving stream resulted in substantial recovery of the total bacterial community. The bacterial groups that are commonly used as indicators do not provide an accurate representation of the response of the bacterial community to disinfectant exposure and subsequent recovery in the environment. UV irradiation and chlorination/dechlorination both accomplished measurable inactivation of indigenous phage; however, the extent of inactivation was fairly modest under the conditions of disinfection used in this study. UV irradiation was consistently more effective as a virucide than chlorination/dechlorination under the conditions of application, based on measurements of virus (phage) diversity and concentration. Taken together, and when considered in conjunction with previously published research, the results of these experiments illustrate several important limitations of common disinfection processes as applied in the treatment of municipal wastewaters. In general, it is not clear that conventional disinfection processes, as commonly implemented, are effective for control of the risks of disease transmission, particularly those associated with viral pathogens. Microbial quality in receiving streams may not be substantially improved by the application of these disinfection processes; under some circumstances, an argument can be made that disinfection may actually yield a decrease in effluent and receiving water quality. Decisions regarding the need for effluent disinfection must account for site-specific characteristics, but it is not clear that disinfection of municipal wastewater effluents is necessary or beneficial for all facilities. When direct human contact or ingestion of municipal wastewater effluents is likely, disinfection may be necessary. Under these circumstances, UV irradiation appears to be superior to chlorination in terms of microbial quality and chemistry and toxicology. This advantage is particularly evident in effluents that contain appreciable quantities of ammonia-nitrogen or organic nitrogen.  相似文献   

18.
Gamma and electron-beam irradiation of Bacillus subtilis spores suspended in different types of water was studied to evaluate the inactivation of the spores and assess their possible use as a bioindicator for radiation processing. We found that the inactivation proceeded endogenously, being dose-rate-dependent and affected by oxygen. The radiation resistance of the suspended spores was found to be rather high; therefore, B. subtilis spores used as a bioindicator for efficiency of water treatment by radiation under practical conditions might result in the spores being overly conservative surrogates for pathogenic microorganisms. Moreover, the doserate dependency impedes the use of the spores as a bioindicator. Thus, B. subtilis spores cannot be recommended as a bioindicator for evaluation of the microbicidal efficacy of ionizing radiation processing of water.  相似文献   

19.
Information on the particle size distribution of bioaerosols emitted from open air composting operations is valuable in evaluating potential health impacts and is a requirement for improved dispersion simulation modelling. The membrane filter method was used to study the particle size distribution of Aspergillus fumigatus spores in air 50 m downwind of a green waste compost screening operation at a commercial facility. The highest concentrations (approximately 8 × 104 CFU m−3) of culturable spores were found on filters with pore diameters in the range 1–2 μm which suggests that the majority of spores are emitted as single cells. The findings were compared to published data collected using an Andersen sampler. Results were significantly correlated (p < 0.01) indicating that the two methods are directly comparable across all particles sizes for Aspergillus spores.  相似文献   

20.
G Matafonova  V Batoev 《Chemosphere》2012,89(6):637-647
Excilamps as modern mercury-free sources of narrow-band UV radiation represent an attractive alternative in environmental applications. This review focuses on recent studies on the water and surface decontamination with excilamps by means of direct photolysis and advanced oxidation processes. To date, direct photolysis and advanced oxidation processes (AOPs) such as UV/H2O2, UV/Fenton and UV/O3 have been applied for degradation of organic compounds (mainly, phenols, dyes and herbicides) in model aqueous solutions. Special emphasis is placed on studies combining UV irradiation (as a pre-treatment or post-treatment step) with biological treatment. In this review, the efficiencies of direct UV, UV/H2O2 and UV/TiO2 processes for inactivation of a variety of pathogenic microorganisms in water and on surfaces are discussed. The analysis of the literature shows that more works need to be done on scaling up the processes, degradation/mineralization of target pollutant(s) in real effluents and evaluation of energy requirements.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号