首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 350 毫秒
1.
Aerosol water content was determined from relative humidity controlled optical particle counter (ASASP-X) size distribution measurements made during the Southeastern Aerosol and Visibility Study (SEAVS) in the Great Smoky Mountains National Park during summer 1995. Since the scattering response function of the ASASP-X is sensitive to particle refractive index, a technique for calibrating the ASASP-X for any real refractive index was developed. A new iterative process was employed to calculate water mass concentration and wet refractive index as functions of relative humidity. Experimental water mass concentrations were compared to theoretically predicted values assuming only ammonium sulfate compounds were hygroscopic. These comparisons agreed within experimental uncertainty. Estimates of particle hygroscopicity using a rural aerosol model of refractive index as a function of relative humidity demonstrated no significant differences from those made with daily varying refractive index estimates. Although aerosol size parameters were affected by the assumed chemical composition, forming ratios of these parameters nearly canceled these effects.  相似文献   

2.
ABSTRACT

Aerosol size distributions were measured during the summertime 1995 Southeastern Aerosol and Visibility Study (SEAVS) in Great Smoky Mountains National Park using an Active Scattering Aerosol Spectrometer (ASASP-X) optical particle counter. We present an overview of the experimental method, our data inversion technique, timelines of the size distribution parameters, and calculations of dry accumulation mode aerosol density and refractive index. Aerosol size distributions were recorded during daylight hours for aerosol in the size range 0.1 < Dp < 2.5 u,m. The particle refractive index used for the data inversion was calculated with the partial molar refractive index approach using 12-hr measured aerosol chemical composition. Aerosol accumulation mode volume concentrations ranging from 1 to 26 u,m3 cm-3 were observed, with an average of 7 ± 5 u,m3 cm-3. The study average dry accumulation mode geometric volume median diameter was 0.27 ± 0.03 u,m, and the mean geometric standard deviation was 1.45 ± 0.06. Using an internally mixed aerosol model, and assuming chemical homogeneity across the measured particle distribution, an average accumulation mode dry sulfate ion mass scattering efficiency of 3.8 ± 0.6 m2 g-1 was calculated.  相似文献   

3.
Aerosol size distributions were measured during the summertime 1995 Southeastern Aerosol and Visibility Study (SEAVS) in Great Smoky Mountains National Park using an Active Scattering Aerosol Spectrometer (ASASP-X) optical particle counter. We present an overview of the experimental method, our data inversion technique, timelines of the size distribution parameters, and calculations of dry accumulation mode aerosol density and refractive index. Aerosol size distributions were recorded during daylight hours for aerosol in the size range 0.1 < Dp < 2.5 microns. The particle refractive index used for the data inversion was calculated with the partial molar refractive index approach using 12-hr measured aerosol chemical composition. Aerosol accumulation mode volume concentrations ranging from 1 to 26 micron 3 cm-3 were observed, with an average of 7 +/- 5 micron 3 cm-3. The study average dry accumulation mode geometric volume median diameter was 0.27 +/- 0.03 micron, and the mean geometric standard deviation was 1.45 +/- 0.06. Using an internally mixed aerosol model, and assuming chemical homogeneity across the measured particle distribution, an average accumulation mode dry sulfate ion mass scattering efficiency of 3.8 +/- 0.6 m2 g-1 was calculated.  相似文献   

4.
Abstract

The hygroscopic properties of the organic fraction of aerosols are poorly understood. The ability of organic aerosols to absorb water as a function of relative humidity (RH) was examined using data collected during the 1999 Big Bend Regional Aerosol and Visibility Observational Study (BRAVO). (On average, organics accounted for 22% of fine particulate matter with an aerodynamic diameter less than 2.5 µm (PM2.5) mass). Hourly RH exceeded 80% only 3.5% of the time and averaged 44%. BRAVO aerosol chemical composition and dry particle size distributions were used to estimate PM2.5 light scattering (Bsp) at low and high ambient RH. Liquid water growth associated with inorganic species was sufficient to account for measured Bsp for RH between 70 and 95%.  相似文献   

5.
The hygroscopic properties of the organic fraction of aerosols are poorly understood. The ability of organic aerosols to absorb water as a function of relative humidity (RH) was examined using data collected during the 1999 Big Bend Regional Aerosol and Visibility Observational Study (BRAVO). (On average, organics accounted for 22% of fine particulate matter with an aerodynamic diameter less than 2.5 microm (PM2.5) mass). Hourly RH exceeded 80% only 3.5% of the time and averaged 44%. BRAVO aerosol chemical composition and dry particle size distributions were used to estimate PM2.5 light scattering (Bsp) at low and high ambient RH. Liquid water growth associated with inorganic species was sufficient to account for measured Bsp for RH between 70 and 95%.  相似文献   

6.
ABSTRACT

The Southeastern Aerosol and Visibility Study (SEAVS) was undertaken to characterize the size-dependent composition, thermodynamic properties, and optical characteristics of the ambient atmospheric particles in the southeastern United States. The field portion of the study was carried out from July 15 to August 25, 1995.

As part of the study a relative humidity controlled inlet was built to raise or lower the relative humidity to predetermined levels before the aerosol was passed into an integrating nephelometer or particle-sizing device. Five other integrating nephelometers were operated in various configurations, two of which were fitted with a 2.5 μm inlet. Fine particle (<2.5 μm) samplers were operated to measure concentrations of sulfate, nitrate, and ammonium ions, organic and elemental carbon, and fine soil. Mass size distributions were measured with an eight-stage, single orifice cascade impactor.  相似文献   

7.
Abstract

The Interagency Monitoring of Protected Visual Environments (IMPROVE) equation used to assess compliance under the U.S. Environmental Protection Agency (EPA) Haze Rule assumes that dry mass scattering efficiencies for aerosol chemical components are constant. However, examination of aerosol size distributions and chemical composition during the Big Bend Regional Aerosol and Visibility Observational Study and the Southeastern Aerosol and Visibility Study suggests that volume and mass scattering efficiencies vary directly with increasing particle light scattering and aerosol mass concentration. This is consistent with the observation that particle distributions were shifted to larger sizes under more polluted conditions and appears to be related to aging of the aerosol during transport to remote locations.  相似文献   

8.
The Southeastern Aerosol and Visibility Study (SEAVS) was undertaken to characterize the size-dependent composition, thermodynamic properties, and optical characteristics of the ambient atmospheric particles in the southeastern United States. The field portion of the study was carried out from July 15 to August 25, 1995. As part of the study a relative humidity controlled inlet was built to raise or lower the relative humidity to predetermined levels before the aerosol was passed into an integrating nephelometer or particle-sizing device. Five other integrating nephelometers were operated in various configurations, two of which were fitted with a 2.5 microns inlet. Fine particle (< 2.5 microns) samplers were operated to measure concentrations of sulfate, nitrate, and ammonium ions, organic and elemental carbon, and fine soil. Mass size distributions were measured with an eight-stage, single orifice cascade impactor. Four different strategies for estimating scattering were used. First, an externally mixed model with constant specific scattering coefficients, sulfate ion mass interpreted as ammonium bisulfate, and ammonium bisulfate growth as a function of relative humidity, is assumed. Second, an externally mixed aerosol model, assuming constant dry specific scattering but with sulfate ammoniation and associated composition-dependent hygroscopicity explicitly accounted for, is used. Third, an externally mixed aerosol model, but with sulfate ammoniation, associated growth as a function of relative humidity, and sulfate size distributions, is applied. Fourth, an internally mixed aerosol model with measured sulfur size distributions and estimated size distributions for other species is used with the growth characteristics of the mixture being estimated using the Zdanovskii-Stokes-Robinson (ZSR) assumptions. Only ionic species were considered to be hygroscopic. The second, third, and fourth approaches yield similar results with reconstructed scattering comparing quite favorably with measured scattering. Accounting for sulfate ammoniation and associated water uptake was the most important detail in achieving closure between measurements and modeled scattering. In general, differences between estimated scattering, assuming internally or externally mixed models, was small. These same models were used to estimate wet to dry scattering ratios. The R2 for an ordinary least-squares regression between measured and predicted ratios was high (0.71-0.92), and in most cases the scattering ratio was insensitive to modeling assumptions. However, during some sample periods differences between predicted scattering ratios for the different modeling assumptions were as high as 30%.  相似文献   

9.
Simultaneous continuous measurements have been made at an urban background site of PM10 mass by Tapered Element Oscillating Microbalance, particle number density by condensation nucleus counter and Fuchs surface area using an epiphaniometer. Concurrent measurements of gaseous NOx and CO have been used to indicate road traffic emissions, and data from a nearby meteorological station have been used for relative humidity, temperature and windspeed. The data indicate that particle number density is a far better indicator of traffic activity than PM10 mass which is strongly influenced by a high background, and also tends to peak rather later than the gaseous pollutants and particle number, presumably as a result of advection of accumulation mode aerosol. PM10 mass and Fuchs surface area generally show a very similar temporal trend, although there is a tendency for the ratio of surface area to dry particle mass to increase with relative humidity. The sampling period included bonfire night celebrations which caused substantial increases in all particle parameters, although the ratio of particle mass to number was considerably higher than for the morning rush hour road traffic-influenced peak.  相似文献   

10.
ABSTRACT

Measurements collected using five real-time continuous airborne particle monitors were compared to measurements made using reference filter-based samplers at Bakers-field, CA, between December 2, 1998, and January 31, 1999. The purpose of this analysis was to evaluate the suitability of each instrument for use in a real-time continuous monitoring network designed to measure the mass of airborne particles with an aerodynamic diam less than 2.5 μm (PM2.5) under wintertime conditions in the southern San Joaquin Valley. Measurements of airborne particulate mass made with a beta attenuation monitor (BAM), an integrating nephelometer, and a continuous aerosol mass monitor (CAMM) were found to correlate well with reference measurements made with a filter-based sampler. A Dusttrak aerosol sampler overestimated airborne particle concentrations by a factor of ~3 throughout the study. Measurements of airborne particulate matter made with a tapered element oscillating microbalance (TEOM) were found to be lower than the reference filter-based measurements by an amount approximately equal to the concentration of NH4NO3 observed to be present in the airborne particles. The performance of the Dusttrak sampler and the integrating nephelometer was affected by the size distribution of airborne particulate matter. The performance of the BAM, the integrating nephelometer, the CAMM, the Dusttrak sampler, and the TEOM was not strongly affected by temperature, relative humidity, wind speed, or wind direction within the range of conditions encountered in the current study. Based on instrument performance, the BAM, the integrating nephelometer, and the CAMM appear to be suitable candidates for deployment in a real-time continuous PM2.5 monitoring network in central California for the range of winter conditions and aerosol composition encountered during the study.  相似文献   

11.
Aerosol size distributions were measured in the air exhausted from a horizontal spike Soderberg aluminum reduction cell at the Kaiser Aluminum and Chemical Corporation plant in Tacoma, Wash. The particle size distributions were measured with the University of Washington cascade impactor, developed specifically for source testing. The particle mass concentrations and size distributions were found to vary significantly with changes in the cell process operations. For a typical aerosol size distribution at the exit of the cell hood the mass mean particle diameter was 5.5 microns and the particle size standard geometric deviation was 25.  相似文献   

12.
Abstract

In developing countries, high levels of particle pollution from the use of coal and biomass fuels for household cooking and heating are a major cause of ill health and premature mortality. The cost and complexity of existing monitoring equipment, combined with the need to sample many locations, make routine quantification of household particle pollution levels difficult. Recent advances in technology, however, have enabled the development of a small, portable, data-logging particle monitor modified from commercial smoke alarm technology that can meet the needs of surveys in the developing world at reasonable cost. Laboratory comparisons of a prototype particle monitor developed at the University of California at Berkeley (UCB) with gravi-metric filters, a tapered element oscillating microbalance, and a TSI DustTrak to quantify the UCB particle monitor response as a function of both concentration and particle size and to examine sensor response in relation to changes in temperature, relative humidity, and elevation are presented here. UCB particle monitors showed good linearity in response to different concentrations of laboratory-generated oleic acid aerosols with a coarse (mass median diameter, 2.1 µm) and fine (mass median diameter, 0.27–0.42 µm) size distributions (average r2 = 0.997 ± 0.005). The photoelectric and ionization chamber showed a wide range of responses based on particle size and, thus, require calibration with the aerosol of interest. The ionization chamber was five times more sensitive to fine rather than coarse particles, whereas the photoelectric chamber was five times more sensitive to coarse than fine. The ratio of the response between the two sensors has the potential for mass calibration of individual data points based on estimated parameters of the size distribution. The results demonstrate the significant potential of this monitor, which will facilitate the evaluation of interventions (improved fuels, stoves, and ventilation) on indoor air pollution levels and research on the impacts of indoor particle levels on health in developing countries.  相似文献   

13.
Indoor sources have been identified as a major contributor to the increase of particle concentration in indoor environments. The work presented here is a study of the characteristics of particulate matter number size distribution and mass concentration under controlled indoor activities in a laboratory room. The objective is to characterize particulate matter concentrations indoors resulted under the influence of specific sources. Measurements were performed in an empty laboratory (period September–October 2006) using a GRIMM SMPS+C system (particle size range between 11.1 and 1083.3 nm), a DustTrak Aerosol Monitor (TSI) and a P-Trak Ultrafine Particle Counter (TSI). The studied indoor activities included candle burning, hot plate heating, water boiling, onion frying, vacuuming, hair drying, hair spraying, smoking and burning of incense stick. The AMANpsd computer algorithm was used to evaluate the modal structure of measured particle number size distribution data. Furthermore, the change of the particle number size distribution shape under the influence of different emission sources was studied versus time. Finally the particle emission rates were computed. High particle number concentrations were observed during smoking, onion frying, candle burning and incense stick burning. The highest particle mass concentrations were measured during smoking and hair spraying. The shift of the particle size distribution to larger diameters suggests the presence of strong coagulation effect during candle burning, incense stick burning, smoking and onion frying. The size distribution was mainly bimodal during onion frying and candle burning, whereas the size distribution remained unimodal during incense stick burning and smoking experiments.  相似文献   

14.
The U.S. Environmental Protection Agency (EPA) has proposed a new secondary standard based on visibility in urban areas. The proposed standard will be based on light extinction, calculated from 24-hr averaged measurements. It would be desirable to base the standard on a shorter averaging time to better represent human perception of visibility. This could be accomplished by either an estimation of extinction from semicontinuous particulate matter (PM) data or direct measurement of scattering and absorption. To this end we have compared 1-hr measurements of fine plus coarse particulate scattering using a nephelometer, along with an estimate of absorption from aethalometer measurements. The study took place in Lindon, UT, during February and March 2012. The nephelometer measurements were corrected for coarse particle scattering and compared to the Filter Dynamic Measurement System (FDMS) tapered element oscillating microbalance monitor (TEOM) PM2.5 measurements. The two measurements agreed with a mass scattering coefficient of 3.3 ± 0.3 m2/g at relative humidity below 80%. However, at higher humidity, the nephelometer gave higher scattering results due to water absorbed by ammonium nitrate and ammonium sulfate in the particles. This particle-associated water is not measured by the FDMS TEOM. The FDMS TEOM data could be corrected for this difference using appropriate IMPROVE protocols if the particle composition is known. However, a better approach may be to use a particle measurement system that allows for semicontinuous measurements but also measures particle bound water. Data are presented from a 2003 study in Rubidoux, CA, showing how this could be accomplished using a Grimm model 1100 aerosol spectrometer or comparable instrument.

Implications: Visibility is currently based on 24-hr averaged PM mass and composition. A metric that captures diurnal changes would better represent human perception. Furthermore, if the PM measurement included aerosol bound water, this would negate the need to know particulate composition and relative humidity (RH), which is currently used to estimate visibility. Methods are outlined that could accomplish both of these objectives based on use of a PM monitor that includes aerosol-bound water. It is recommended that these techniques, coupled with appropriate measurements of light scattering and absorption by aerosols, be evaluated for potential use in the visibility based secondary standard.  相似文献   

15.
Abstract

The concentration of fine particulate nitrate, sulfate, and carbonaceous material was measured for 12-hr day-night samples using diffusion denuder samplers during the Project Measurement of Haze and Visibility Effects (MOHAVE) July to August 1992 Summer Intensive study at Meadview, AZ, just west of Grand Canyon National Park. Organic material was measured by several techniques. Only the diffusion denuder method measured the semivolatile organic material. Fine particulate sulfate and nitrate (using denuder technology) determined by various groups agreed. Based on the various collocated measurements obtained during the Project MOHAVE study, the precision of the major fine particulate species was ±0.6 μg/m3 organic material, ±0.3 μg/m3 ammonium sulfate, and ±0.07 μg/m3 ammonium nitrate. Data were also available on fine particulate crustal material, fine and coarse particulate mass from the Interagency Monitoring of Protected Visual Environments sampling system, and relative humidity (RH), light absorption, particle scattering, and light extinction measurements from Project MOHAVE. An extinction budget was obtained using mass scattering coefficients estimated from particle size distribution data. Literature data were used to estimate the change in the mass scattering coefficients for the measured species as a function of RH and for the absorption of light by elemental carbon. Fine particulate organic material was the principal particulate contributor to light extinction during the study period, with fine particulate sulfate as the second most important contributor. During periods of highest light extinction, contributions from fine particulate organic material, sulfate, and light-absorbing carbon dominated the extinction of light by particles. Particle light extinction was dominated by sulfate and organic material during periods of lowest light extinction. Combination of the extinction data and chemical mass balance analysis of sulfur oxides sources in the region indicate that the major anthropogenic contributors to light extinction were from the Los Angeles, CA, and Las Vegas, NV, urban areas. Mohave Power Project associated secondary sulfate was a negligible contributor to light extinction.  相似文献   

16.
With the development of satellite experiments supplementary and validating ground-based measurements are gaining growing importance for the inference and evaluation of radiation-related aerosol parameters. Both kinds of measurements have been conducted and interpreted mainly under globally or locally restricted aspects for a limited time period only. Results are presented from four rural regions (coastal zone, lowlands, highlands, high mountain); they are column-related aerosol parameters, deduced from monitoring programs of spectral aerosol optical depth (AOD) as well as almucantar sky irradiance measurements. After 13 years of continuous measurements of trends and variations in aerosol optical depths, these results are based on 5 years of data collection (1994–1998). There are significant differences among the parameters of the four regions when related to the inversion method of the AOD spectra. A clear interdependence was found between all column-related parameters and the real part of the refractive index, which in turn depends on the chosen retrieval method. The differences among the four regions are characterized mainly by their different altitudes, with relative humidity being responsible for their internal variation. An increase in the relative humidity from 35 to 55–60% influences the most interesting parameters such as refractive index (real part), hemispheric backscattered fraction b, and direct radiative forcing ΔF as follows: The real part of the refractive index decreases from 1.6±0.05 to 1.42±0.04, b decreases by 8–10%, and, due to the increase in AOD, ΔF increases by about 20% in the spectral region 0.4–1.0 μm. The quantities of the parameters depend on the retrieval methods too.  相似文献   

17.
Abstract

Aerosol size distributions from ferrous foundry cupola furnaces vary depending on semicontinuous process dynamics, time along the tap-to-tap cycle, dilution ratio, and the physical and chemical nature of the charge and fuel. All of these factors result in a highly time-dependent emission of particulate matter (PM) 2.5 µm or less in aerodynamic diameter (PM2.5)—even on a mass concentration basis. Control measures are frequently taken on the basis of low-reliability parameters such as emission factors and loosely established mass ratios of PM2.5 to PM 10 µm or less in aerodynamic diameter (PM10). The new environmental requirements could entail unexpected and undesired drawbacks and uncertainties in the meaning and effectiveness of process improvement measures. The development of process-integrated and flue-gas cleaning measures for reduction of particle emissions requires a better knowledge of generation mechanisms during melting. Available aerosol analyzers expand the range of control issues to be tackled and contribute to greatly reduce the uncertainty of engineering decisions on trace pollutant control. This approach combines real-time size distribution monitoring and cascade impactors as preseparators for chemical or morphological analysis. The results allow for establishing a design rationale and performance requirement for control devices. A number size distribution below 10 µm in aerodynamic equivalent diameter was chosen as the main indicator of charge influence and filter performance. Size distribution is trimodal, with a coarse mode more than 12 µm that contributes up to 30% of the total mass. A temporal series for these data leads to identification of the most relevant size ranges for a specific furnace (e.g., the most penetrating size range). In this cupola, this size range is between 0.32 and 0.77 µm of aerodynamic equivalent diameter and defines the pollution control strategy for metals concentrating within this size range. Scrap quality effect is best monitored at less than 0.2 µm in aerodynamic equivalent diameter and has been confirmed as strongly dependent on the physical state of the charge.  相似文献   

18.
A survey on the concentration of particulate matter in the urban atmosphere was carried out in the city of Sao Carlos, Brazil. Five sites were selected for data collection one in the city centre (high concentration of people and automotive vehicles), three in industrial areas, and one at the interface with the countryside. The particle size distribution and mass concentration, temperature, humidity and wind velocity were measured at each site. In the city centre, the concentration of the particles smaller than 10 μm (PM10) was also measured. The particle size distribution was obtained with a laser scattering particle counter. The total and PM10 concentrations were obtained with high volume samplers. The tests were performed for 75 consecutive weeks. The results show that the particle concentration is sensitive to seasonal conditions. During autumn and winter, which is the drier and windy period of the year, larger particles were dispersed, leading to higher concentrations, both total and PM10. The relative humidity varied with the schedule of sampling and with the season the autumn and winter weeks were much drier than the other periods. Higher rainfall levels coincided with lower particle concentrations. All these results are statistically significant.  相似文献   

19.
Abstract

The real-time ambient mass sampler (RAMS) is a continuous monitor based on particle concentrator, denuder, drier, and tapered element oscillating microbalance (TEOM) monitor technology. It is designed to measure PM2.5 mass, including the semi-volatile species NH4NO3 and semi-volatile organic material, but not to measure PM2.5 water content. The performance of the RAMS in an urban environment with high humidity was evaluated during the July 1999 NARSTO-Northeast Oxidant and Particles Study (NEOPS) intensive study at the Baxter water treatment plant in Philadelphia, PA. The results obtained with the RAMS were compared to mass measurements made with a TEOM monitor and to constructed mass obtained with a Particle Concentrator-Brigham Young University Organic Sampling System (PC-BOSS) sampler designed to determine the chemical composition of fine particles, including the semi-volatile species. An average of 28% of the fine particulate material present during the study was semi-volatile organic material lost from a filter during particle collection, and 1% was NH4NO3 that was also lost from the particles during sampling. The remaining mass was dominantly nonvolatile (NH4)2SO4 (31%) and organic material (37%), with minor amounts of soot, crustal material, and nonvolatile NH4NO3. Comparison of the RAMS and PC-BOSS results indicated that the RAMS correctly monitored for fine particulate mass, including the semi-volatile material. In contrast, the heated filter of the TEOM monitor did not measure the semi-volatile material. The comparison of the RAMS and PC-BOSS data had a precision of ±4.1 μg/m3 (±9.6%). The precision of the RAMS data was limited by the uncertainty in the blank correction for the reversible adsorption of water by the charcoal-impregnated cellulose sorbent filter of the RAMS monitor. The precision of the measurement of fine par-ticulate components by the PC-BOSS was ±6-8%.  相似文献   

20.
Abstract

Optical measurements of particle size and concentration were made at the chromium plating tank and exhaust system at a commercial hexavalent chromium plating facility. Particles were examined at three locations in the exhaust system: 1) directly at the hexavalent chromium plating bath surface, 2) at the exit of a cyclone separator located in the exhaust system approximately three to four meters downstream of the bath, and 3) in the exhaust stack, downstream of the induced draft fan and all abatement devices. Particle diameters at the bath surface ranged from 0.3 to 25 μm. Downstream of the cyclone exit and mesh pad filters, particle top sizes were approximately 5 and 0.7 mm, respectively. On a mass basis, the collection efficiency of all abatement devices was 99.997%. Assuming that droplets in the flow consist primarily of water and chromium, correcting the total particle mass flow against water content gives a chromium emission rate of 64,000 μg/hr, which compares favorably with a value of 77,000 μg/hr measured with EPA methods. This initial agreement, which should be validated through additional measurements over a broad range of flow conditions, raises the possibility of continuous monitoring for chromium metal emissions using particle size/mass as a surrogate.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号