首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
A prospective study was performed on 2119 pregnancies that underwent genetic amniocentesis. Indications for amniocentesis were either maternal age (⩾35) or triple-test results (risk⩾1/380). The study covered a 36-month period and assessed the prevalence of minor ultrasound markers both in fetuses with Down syndrome and normal control fetuses at 15–19 week' gestation. Only fetuses with normal karyotype or trisomy 21 were considered. Six minor sonographic markers were considered: nuchal thickness, pyelectasia, femur observed/expected and humerus observed/expected ratios, bowel echogenicity, and choroid plexus cysts. One or more ultrasound soft markers were present in 23 out of 33 fetuses with Down syndrome (70%) and in 572 out of 2069 normal fetuses (28%). Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

2.
The median maternal serum free beta human chorionic gonadotropin (hCG) multiple of the median (MOM) of 480 Down syndrome cases in the second trimester was 2·64, significantly greater than the reported median MOM of intact hCG (p<0·0001). In 234 of these cases from retrospective and prospective studies, the effectiveness of maternal serum free beta hCG was evaluated in combination with alpha-fetoprotein (AFP) and maternal age in second-trimester Down syndrome screening. Down syndrome detection in the gestational age range of 14–16 weeks was 82 per cent. In all gestational weeks (14–22), a 77·7 per cent Down syndrome detection rate was achieved. In prospective screening of 44 272 patients under the age of 35 years, 69 per cent of Down syndrome cases were detected (73 per cent in gestational weeks 14–16). The false-positive rate for the prospective study was 3·8 per cent. The use of free beta hCG combined with maternal serum AFP and maternal age-related risk for Down syndrome in a screening population (i.e., women under 35 years) yields an improved detection efficiency over other protocols.  相似文献   

3.
Assisted reproductive technologies (ART) have increased both the number of pregnancies in women beyond the age of 35 and the incidence of multiple pregnancies. Various methods of screening for Down syndrome (DS) were introduced in clinical practice during the last two decades, and specific problems were encountered when they were applied for twin pregnancies. The current review aims to explore the problematic issue of prenatal DS screening in ART twins. Overall, more women with twin pregnancies (mainly those who conceived via assisted reproduction) are found to be false positive for DS. This is because mid-trimester maternal serum screening is associated with a higher false-positive rate secondary to changes in the feto-placental endocrinologic metabolism, reflected mainly in high human chorionic gonadotrophin (hCG) levels in the ART pregnancies. First-trimester nuchal translucency (NT) measurement in twin pregnancies is not affected by the problems encountered in serum screening. This sonographic screening approach enables a fetus-specific identification of those fetuses at high risk of DS and is associated with a lower false-positive rate than mid-trimester serum screening. DS screening in ART twins presents several challenges in determining the most appropriate screening test modality. Whether there is any significant benefit of adding first-trimester biochemistry or nasal bone scanning in screening ART-conceived twins awaits further investigation. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

4.
This review summarizes the development, history and use of second-trimester sonographic markers for the detection of fetal Down syndrome over three decades. Starting with the nuchal fold thickening in 1985 and culminating in the genetic sonogram in the 1990s. The combination of second-trimester serum screening with the ultrasound markers improved the detection rate of affected fetuses but also allowed patients to decrease their risk of carrying a fetus with Down syndrome if the genetic sonogram was normal. More recently the role of the genetic sonogram and its markers have changed with the wide spread use of first-trimester screening. This prior screening ultimately decreases the prevalence of fetal Down syndrome in the second trimester to less than 85% of what it was in the first-trimester as most fetuses with Down syndrome are now identified early. Current interpretation of the second-trimester Down syndrome markers must be based on the result of the first trimester and combined screening to achieve the most accurate risk estimate of an affected fetus. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

5.
We assessed the discriminatory efficiency and cost-effectiveness of a novel way of organising first trimester screening for Down syndrome (DS), contingent testing, where a serological test (PAPP-A and β-hCG: the double test) is made in early first trimester and followed by nuchal translucency testing (NT) only in women with an intermediate risk, e.g. <1:65 and >1:1000, and not in all women as in normal first trimester screening (NFTS). Using Monte Carlo simulation contingent testing had a detection rate (DR) of 78.9% and a false-positive rate (FPR) of 4.0% for DS with 19.4% of women offered NT testing. The DR of NFTS was 85.5% and the FPR 4.4%. The decrease in NT screening was associated with an increase from 23% to 29% in the proportion of DS cases born. The cost of the contingent testing programme was £53 000 per DS case not born and £91 000 in NFTS. The number of aborted fetuses per DS case were 0.35 and 0.36, respectively. Thus, contingent testing is an organisation of first trimester screening where costs can be reduced with a marginal decrease in performance. Contingent testing is attractive in areas where NT screening is the bottleneck preventing the introduction of first trimester screening. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

6.
The effect of repeat testing in maternal serum multiple marker screening for Down's syndrome was estimated using samples stored in an antenatal serum bank. Human chorionic gonadotropin (hCG) and unconjugated oestriol (uE3) levels were determined in 142 pairs of routinely collected samples which had already been tested for alpha-fetoprotein (AFP). For each marker, about two-thirds of the pairs of values were within 20 per cent of each other and most were within 40 per cent. A multivariate Gaussian model was used to estimate the detection and false-positive rates for different repeat testing policies. A policy of repeat testing those with a high risk of a Down's syndrome term pregnancy given age and marker levels would reduce the false-positive rate but there would also be a reduction in the detection rate. For example, using all three markers and a 1 in 250 cut-off risk, the estimated false-positive rate would fall from 5·3 to 3·8 per cent but the detection rate would decrease from 58 to 55 per cent. A policy of repeating those with either high or borderline risks would produce a modest improvement in screening efficiency. Repeating the 11 per cent with a risk exceeding 1 in 500 yields an estimated false-positive rate of 5·0 per cent and a detection rate of 60 per cent. A policy of selective repeat testing is not recommended as it would not substantially improve screening efficiency. Nonetheless, if a repeat test has been performed, the parameters given in this paper will enable an unbiased estimate of the Down's syndrome risk to be calculated for individual women.  相似文献   

7.
Serum measurements of pregnancy-associated plasma protein A (PAPP-A) and the free β-human chorionic gonadotrophin (hCG) subunit were made in 13 women with Down syndrome (DS) pregnancies and six other women with fetal aneuploidy ascertained at chorionic villus sampling (CVS), as well as 89 women with contemporaneous normal control pregnancies. Median serum PAPP-A measurements (0·31 MOM, 95 per cent confidence interval (CI) 0·22–0·65 vs. normal 1·06, 95 per cent CI 0·89–1·20) were lower and free β-hCG subunit measurements (1·13 MOM, 95 per cent CI 0·93–2·63 vs. normal 0·91, 95 per cent CI 0·79–1·03) were higher at statistically significant levels. Receiver operator characteristic (ROC) curves showed that the highest sensitivity for detection, 71·2 per cent (95 per cent CI 54·7–87·6 per cent), was for depressed PAPP-A levels; the combination of low serum PAPP-A levels, maternal age, and elevated free β-hCG levels yielded a detection rate of 78·9 per cent (95 per cent CI 64·9–92·8 per cent) of the affected pregnancies at 8–12 weeks' gestation.  相似文献   

8.
The relationship between first-trimester maternal serum Schwangerschafts protein 1 (SP1) and the karyotype of the pregnancy was examined in 692 women who underwent chorionic villus biopsy at 6–12 weeks. There were 30 pregnancies with abnormal karyotypes, consisting of 14 Down's syndrome (DS), eight trisomy 18, and eight other anomalies, two of which were mosaics. The normal ranges and medians for gestation were defined from the 662 cases in which the karyotype was normal. The median SP1 (0·5 MOM) of the abnormal group was significantly lower than that of the normal group (10 MOM). This relationship was maintained for the DS pregnancies (0·4 MOM) and for anomalies other than trisomy 18 (0·43 MOM) but not trisomy 18 (1·1 MOM). It is possible that the use of SP1 as a screening test for chromosome anomalies in the first trimester could have a 43 per cent detection rate for a 5 per cent false-positive rate.  相似文献   

9.
For the last 6 years, sonographic signs for excessive fluid accumulation in the backs of 10- to 12-week-old fetuses have been looked for prior to transabdominal chorionic biopsy. In 1400 pregnancies, subsequent karyotype analyses revealed 28 cases of Down syndrome. In 15 ( = 54 per cent), a large fluid cushion over most of the back had been documented at the time of biopsy. Only a few chromosomally normal fetuses with the same peculiarity were observed. The cushion was also present in fetuses with trisomies 18 and 13 , and in Turner syndrome. Systematic first-trimester screening for nuchal fluid accumulation seems to be a recommended method for the detection of Down syndrome and other chromosome anomalies in young pregnant women at low risk. It compares favourably with current methods of maternal serum screening performed at 16–18 weeks which require a higher number of invasive procedures.  相似文献   

10.
Over a 2-year period from January 1991 to December 1992, second-trimester maternal serum screening for Down's syndrome using alpha-fetoprotein (aFP), human chorionic gonadotrophin (hCG), and unconjugated oestriol (uE3) was made available to five health districts in East Anglia, with a total population of 1·2 million. Amniocentesis was offered when the risk of Down's syndrome at term was 1:200 or greater. 25359 singleton pregnancies were screened, representing an uptake of 77 per cent. The recall rate for the 24 per cent of women who had not had a dating scan prior to the test was 9·4 per cent compared with 3·9 per cent for those who had been scanned (P<0·0005). Seventy-five per cent (36/48) of Down's syndrome pregnancies were detected for a false-positive rate of 4·0 per cent. Twenty-five out of 36 of detected Down's syndrome pregnancies were dated by scan prior to sampling, and in the 11 remaining cases, the dates were confirmed by scan after a high-risk result was obtained. The exclusion of uE3 from the screening protocol would have reduced the detection rate to 52 per cent (25/48) for the same false-positive rate. Eighty-five per cent of women identified at high risk accepted the offer of an amniocentesis. Other fetal abnormalities detected were trisomy 18 (3), trisomy 13 (2), 45,X (6), 69,XXX (5), other chromosome abnormalities (9), open neural tube defects (26), hydrocephalus (7), abdominal wall defects (4), and steroid sulphatase deficiency (6).  相似文献   

11.
This prospective study investigates the relationship between insulin-dependent diabetes and maternal serum levels of alpha-fetoprotein (AFP), unconjugated oestriol (uE3), and human chorionic gonadotropin (hCG). It also examines the potential impact on screening for Down syndrome. The population-based cohort included 20 321 pregnant women in Maine who underwent routine serum screening for Down syndrome in the second trimester. The cohort included 52 women with insulin-dependent diabetes. Maternal serum AFP levels are now routinely adjusted for insulin-dependent diabetes. These adjustments, therefore, were made routinely in the diabetic women, but no equivalent adjustments were made for uE3 and hCG values. The initial false-positive rate (using all three markers) among the women with diabetes was not significantly different from that in the non-diabetic population (7·7 and 5·4 per cent, respectively). Prior to adjustment for insulin-dependent diabetes, the median AFP level in the 52 women was 0·73 multiples of the median (MOM); the median levels of uE3 and hCG were 0·93 and 0·98 MOM, respectively. When the uE3 and hCG levels were adjusted, the initial false-positive rate was unchanged. Median serum levels of uE3 were significantly higher in the 33 women whose onset of diabetes was prior to 19 years of age (0·99 MOM) than in the 19 women whose onset of diabetes was at age 19 or older (0·84 MOM). This is the first population-based study to investigate the relationship between diabetes and serum levels of AFP, uE3, and hCG, and confirms earlier observations from a case—control study that found only slightly lower uE3 and hCG levels.  相似文献   

12.
Free β-HCG is a new analyte that has been suggested to be superior to total HCG when used in combination with alpha-fetoprotein (AFP) for Down syndrome risk screening in early pregnancy. We have evaluated this claim on 21 samples collected from Down syndrome pregnancies and 180 samples from unaffected pregnancies. The detection rates for the combination of AFP with free β-HCG or the combination of AFP with total HCG were identical (71 per cent) but the initial screen positive rate (equivalent to the false-positive rate) was 7·5 per cent for AFP+free β-HCG screening compared with 3·5 per cent for AFP+ total HCG screening. We conclude that the case for free β-HCG is unproven and suggest that further data be collected before free β-HCG becomes acceptable.  相似文献   

13.
In pregnancies obtained after assisted reproduction the false-positive rate of second trimester Down syndrome (DS) screening is increased by 1.5–3-fold. This may cause an increase in the number of amniocenteses and the fetal loss rate. The present study for the first time examined whether assisted reproductive technologies affect the results of first trimester screening. The markers PAPP-A, free β-hCG and the nuchal translucency (NT) thickness were examined at 12–14 weeks' gestation. Screening markers in 47 in vitro fertilisation (IVF), 63 ovulation induction (OI) and 3026 spontaneously conceived singleton pregnancies were compared. The MoM (multiples of the median) value in the IVF pregnancies was 1.02 (95% CI: 0.85–1.22) for PAPP-A, 1.14 (95% CI: 0.95–1.37) for β-hCG and 0.97 (95% CI: 0.89–1.05) for NT; the MoM value in the OI pregnancies was 0.89 (95% CI: 0.76–1.05) for PAPP-A, 1.08 (95% CI: 0.93–1.25) for β-hCG and 1.02 (95% CI: 0.95–1.11) for NT. The first trimester marker values in assisted reproductive pregnancies and spontaneously conceived pregnancies were not significantly different. Estimated false-positive rates for a risk cut-off of 1:400 varied from 4.7% in IVF pregnancies to 5.1% in OI pregnancies. Therefore the false-positive rate in Down syndrome screening should be independent of the method of conception. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

14.
Our aim was to evaluate the potential value of the ratio of the maternal urinary beta-core fragment of human chorionic gonadotropin (βC-hCG) to creatinine (Cr) in discriminating between normal pregnancies and pregnancies associated with fetal chromosomal abnormalities. We hypothesized that pregnancies with fetal chromosomal abnormalities had abnormal quantities of βC-hCG in the urine. The aims of the present study were to investigate retrospectively whether maternal urinary ratios of βC-hCG/Cr are abnormal in women carrying fetuses with chromosome aberrations and to determine normative median values and a reference range for βC-hCG/Cr between 14 and 19 weeks' gestation. Maternal urinary βC-hCG and Cr concentrations were measured in 150 healthy women from 14 to 19 weeks and compared with ten cases of fetal chromosomal abnormalities matched for gestational age. The preliminary cut-off points corresponded to 0·29 multiple of the normal median (MOM) and 2·83 MOM, which were equivalent to the tenth and 90th centiles of the normal range. Of ten cases of fetal chromosomal abnormalities, one out of one (100 per cent) case with trisomy 18 and three of four (75 per cent) cases of variant 9 chromosome had low βC-hCG/Cr (≤0·29 MOM). One of five (20 per cent) cases with Down syndrome had elevated βC-hCG/Cr (≤2·83 MOM). Urinary βC-hCG/Cr ratios obtained in the second trimester may be useful for improved detection efficiency of Down syndrome, trisomy 18, and inversion of chromosome 9. Second-trimester maternal urinary βC-hCG/Cr should be investigated further as a potential marker for fetal chromosome anomalies.  相似文献   

15.
The use of prenatal ultrasound has proven efficacious for the prenatal diagnosis of chromosomal abnormalities. The first sonographic sign of Down syndrome, the thickened nuchal fold, was first described in 1985. Since that time, multiple sonographically-identified markers have been described as associated with Down syndrome. The genetic sonogram, involving a detailed search for sonographic signs of aneuploidy, can be used to both identify fetuses at high risk for aneuploidy and, when normal, can be used to decrease the risk for aneuploidy for a pregnancy when no sonographic markers are identified. Combining the genetic sonogram with maternal serum screening may be the best method of assessing aneuploidy risk for women who desire such an assessment in the second trimester. Trisomy 18, Trisomy 13, and triploidy are typically associated with sonographically identified abnormalities and have a high prenatal detection rate. The use of the described sonographic signs in low-risk women requires further investigation, however, patients at increased risk for aneuploidy due to advanced maternal age or abnormal serum screening can benefit from a genetic sonogram screening for sonographic signs of aneuploidy to adjust their baseline risk of an affected fetus. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

16.
We investigated the contribution of different screening criteria to the prenatal detection of Down syndrome (DS) as well as other chromosomal anomalies in the Jewish population in Israel during 1990 and 1992. There was a significant decrease (P<0·03) in the incidence of DS live-births during 1992 (40:78 442) compared with 1990 (69:73 751) which paralleled a marked increase in total prenatal testing and in DS cases detected prenatally. Private laboratories, which perform amniocenteses mostly for women with a low risk of DS and without genetic counselling, had a significantly lower detection rate (1:917) compared with that of the genetic institutes, which following genetic counselling test both women ≥ 37 years of age (1:91) and women younger than 37 years (1:113). The detection of chromosomal anomalies other than DS was less affected by the reason for amniocentesis. Amniocentesis indicated by maternal serum marker screening of women younger than 37 years identified a greater number of chromosomal anomalies other than DS than amniocentesis based on age (≥37 years) alone (111:9604 versus 94:9810; P<0·06). Prenatal detection of DS is most effective when the indication for amniocentesis follows genetic counselling. The increasing use of maternal serum marker screening leads to a significant improvement in the positive detection rate of chromosomal anomalies other than DS in young women.  相似文献   

17.
Cytogenetic data are presented from a total of 1306 consecutive pregnancies with successful diagnosis obtained from both chorionic villi after short-time culture (CVS-SC) and amniotic fluid cell cultures (AC); samples had been taken simultaneously at combined placentacentesis (placental biopsy) and amniocentesis during the second (92·8 per cent) and third (7·2 per cent) trimesters. Concordant results were obtained in 1218 pregnancies with a normal karyotype and in 62 pregnancies with an aberrant fetal karyotype. Discrepant, i. e. false-positive and false-negative, results were found in 26 cases (2 per cent). From these data the accuracy of CVS-SC, defined as the proportion of all correct diagnoses, is calculated to be 98 per cent. Three non-mosaic and 14 mosaic false-positive results obtained after CVS-SC could not be confirmed by AC. Related to 1235 true normal fetal karyotypes, the specificity of CVS-SC, i.e. the proportion of normal karyotypes correctly diagnosed, amounts to 98·6 per cent. In nine pregnancies, an aberrant fetal karyotype detected after AC was missed by CVS-SC. The sensitivity of CVS-SC, i.e. the proportion of abnormal fetuses correctly diagnosed (62 out of 71), amounts to 87·3 per cent in our study group.  相似文献   

18.
Objectives The aim of this study was to evaluate the role of nasal bone assessment in first-trimester screening for Down syndrome (DS) in the Korean population. Methods From July 2004 to March 2006, we prospectively evaluated the fetal nasal bones at 11–14 weeks' gestation in the Korean population. Results A successful evaluation was possible in 6490 of 6787 fetuses (95.6%). Absent, hypoechoic, and short nasal bones were seen in 4 (26.7%), 4 (26.7%), and 1 (6.7%) of 15 fetuses with DS, respectively, whereas in 5 (0.1%), 11 (0.2%), and 246 (3.8%) of 6456 normal fetuses. The incidence of absent and hypoechoic nasal bone showed significant differences between normal fetuses and fetuses with DS (P < 0.0005, both). Screening for DS using an absent or hypoechoic nasal bone resulted in a sensitivity of 53.3%, a specificity of 99.8%, a positive likelihood ratio of 215.2, and a negative likelihood ratio of 0.5. Conclusion Our study showed that nasal bone abnormality at 11–14 weeks of gestation had a high association with DS in the Korean population. This suggests that nasal bone assessment can be used to supplement the current first-trimester screening for DS in the Korean population. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

19.
In order to elucidate the consistency between generally used age-dependent risk values for Down syndrome (DS) and estimates of the probability of miscarriage in Down pregnancies we have compared expected numbers with estimated numbers of births with DS in Denmark had no intervention at all been carried out. The expected numbers were calculated from the distribution of newborn children according to maternal age combined with the age-related risk of DS. The estimated numbers of children that actually would have been born without any intervention were estimated from observed numbers of cases of DS, i.e. the cases born plus – with corrections because of the high probability of miscarriage in DS pregnancies – a proportion of those cases discovered prenatally. The analysis was carried out separately for mothers aged 35 years or older and for younger mothers. We found a high degree of compatibility between expected and estimated numbers, probably with a minor underestimation of the expected values for the older mothers. The performance of DS screening in Denmark in the period under consideration (1980–1998) is discussed in relation to the figures presented. Despite the fact that 11.8% of all pregnancies were subjected to an invasive diagnostic procedure, only about 38% of all births with DS were prevented. This means that in the period 1990–1998, reluctance to accept serological screening has indirectly resulted in the birth of almost 300 cases of DS in Denmark and at the same time the miscarriage of an unreasonable high number of normal fetuses. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

20.
This study examined the effect of estimation of gestational age from the menstrual history compared with that from crown—rump length (CRL) measurement on the detection rate of screening for aneuploidies in the first trimester. Pregnancy-associated plasma protein A (PAPP-A) was assayed in blood collected prior to chorionic villus sampling in 356 women with unaffected pregnancies and 28 women with an aneuploid pregnancy. There were 14 Down's syndrome (DS) pregnancies. All pregnancies were dated from menstrual history and CRL measurement. The average CRL gestation in the aneuploid population was 2.5 days less than that derived from the LMP (95 per cent confidence interval (CI) for LMP—CRL gestation: using the algorithm based on unaffected pregnancies 0–3.5 days; using the matched case—control approach 1–4.5 days). The average CRL gestation in the DS population was 2 days less but this did not reach statistical significance (95 per cent CI for LMP—CRL gestation: using the algorithm — 1 to 4.5 days; using the matched case—control approach 0 to 5.5 days). The detection rate of aneuploidies in the first trimester using maternal serum PAPP-A was reduced by 7 per cent (and by 3 per cent for DS) for a 5 per cent false-positive rate when using CRL rather than LMP to date the pregnancy. This phenomenon is a consequence of an apparent reduction of gestational age when estimated by CRL in the aneuploid population. Further studies are required to evaluate whether CRL is an unbiased estimate of gestation for Down's syndrome pregnancies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号