首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A radiation fog physics, gas- and aqueous-phase chemistry model is evaluated against measurements in three sites in the San Joaquin Valley of California (SJV) during the winter of 1995. The measurements include for the first time vertically resolved fog chemical composition measurements. Overall the model is successful in reproducing the fog dynamics as well as the temporal and spatial variability of the fog composition (pH, sulfate, nitrate, and ammonium concentrations) in the area. Sulfate production in the fog layer is relatively slow (1–4 μg m−3 per fog episode) compared to the episodes in the early 1980s because of the low SO2 concentrations in the area and the lack of oxidants inside the fog layer. Sulfate production inside the fog layer is limited by the availability of oxidants in the urban areas of the valley and by SO2 in the more remote areas. Nitrate is produced in the rural areas of the valley by the heterogeneous reaction of N2O5 on fog droplets, but this reaction is of secondary importance for the more polluted urban areas. The gas-phase production of HNO3 during the daytime is sufficient to balance the nitrate removed during the nighttime fog episodes. Entrainment of air from the layer above the fog provides another source of reactants for the fog layer. Wet removal is one of most important processes inside the fog layer in SJV. We estimate based on the three episodes investigated during IMS95 that a typical fog episode removes 500–2000 μg m−2 of sulfate, 2500–6500 μg m−2 of nitrate, and 2000–3500 μg m−2 of ammonium. For the winter SJV valley the net fog effect corresponds to reductions in ground ambient concentrations of 0.05–0.2 μg m−3 for sulfate, 3–6 μg m−3 for total nitrate, and 1–3 μg m−3 for total ammonium.  相似文献   

2.
During the course of one year (March 2004–March 2005), PM2.5 particulate nitrate concentrations were semi-continuously measured every 10 min at a Madrid suburban site using the Rupprecht and Patashnick Series 8400N Ambient Particulate Nitrate Monitor (8400N). Gaseous pollutants (NO, NO2, O3, HCHO, HNO2) were simultaneously measured with a DOAS spectrometer (OPSIS AR-500) and complementary meteorological information was obtained by a permanent tower. The particulate nitrate concentrations ranged from the instrumental detection limit of around 0.2 μg m−3, up to a maximum of about 25 μg m−3. The minimum monthly average was reached during August (0.32 μg m−3) and the maximum during November (3.0 μg m−3). Due to the semi-volatile nature of ammonium nitrate, peaks were hardly present during summer air pollution episodes. A typical pattern during days with low dispersive conditions was characterized by a steep rise of particulate nitrate in the morning, reaching maximum values between 9 and 14 UTC, followed by a decrease during the evening. On some occasions a light increase was observed at nighttime. During spring episodes, brief diurnal nitrate peaks were recorded, while during the autumn and winter episodes, later and broader nitrate peaks were registered. Analysis of particulate nitrate and related gaseous species indicated the photo-chemical origin of the morning maxima, delayed with respect to NO and closely associated with secondary NO2 maximum values. The reverse evolution of nitrate and nitrous acid was observed after sunrise, suggesting a major contribution from HNO2 photolysis to OH formation at this time of the day, which would rapidly produce nitrate in both gaseous and particulate phase. Some nocturnal nitrate maxima appeared under high humidity conditions, and a discussion about their origin involving different possible mechanisms is presented, i.e. the possibility that these nocturnal maximum values could be related to the heterogeneous formation of nitrous and nitric acid by the hydrolysis of NO2 on wet aerosols.  相似文献   

3.
A laboratory study was conducted to examine formation of secondary organic aerosols. A smog chamber system was developed for studying gas–aerosol interactions in a dynamic flow reactor. These experiments were conducted to investigate the fate of gas and aerosol phase compounds generated from hydrocarbon–nitrogen oxide (HC/NOx) mixtures irradiated in the presence of fine (<2.5 μm) particulate matter. The goal was to determine to what extent photochemical oxidation products of aromatic hydrocarbons contribute to secondary organic aerosol formation through uptake on pre-existing inorganic aerosols in the absence of liquid water films. Irradiations were conducted with toluene, p-xylene, and 1,3,5-trimethylbenzene in the presence of NOx and ammonium sulfate aerosol, with propylene added to enhance the production of radicals in the system. The secondary organic aerosol yields were determined by dividing the mass concentration of organic fraction of the aerosol collected on quartz filters by the mass concentration of the aromatic hydrocarbon removed by reaction. The mass concentration of the organic fraction was obtained by multiplying the measured organic carbon concentration by 2.0, a correction factor that takes into account the presence of hydrogen, nitrogen, and oxygen atoms in the organic species. The mass concentrations of ammonium, nitrate, and sulfate concentrations as well as the total mass of the aerosols were measured. A reasonable mass balance was found for each of the aerosols. The largest secondary organic aerosol yield of 1.59±0.40% was found for toluene at an organic aerosol concentration of 8.2 μm−3, followed by 1.09±0.27% for p-xylene at 6.4 μg m−3, and 0.41±0.10% for 1,3,5-trimethylbenzene at 2.0 μg m−3. In general, these results agree with those reported by Odum et al. and appear to be consistent with the gas–aerosol partitioning theory developed by Pankow. The presence of organic in the aerosol did not affect significantly the hygroscopic properties of the aerosol.  相似文献   

4.
One hundred ninety-five chemically speciated samples were collected from March 2003 to February 2005 in the Seoul Metropolitan area to investigate the characteristics of the major components in PM2.5 and to characterize the chemical variations between smog and non-smog events. The annual average PM2.5 concentration was 43 μg m−3 that is almost three times higher than the US NAAQS annual PM2.5 standard of 15 μg m−3. During this sampling period, smog and yellow sand events were observed on 27 and 10 days, respectively. The PM2.5 concentrations and its constituents during smog events were about two–three times higher than those during non-smog and yellow sand events. In particular, the mass fractions of secondary aerosols such as sulfate, nitrate, and ammonium during the smog events were higher than those of the other constituents. The mean concentration and mass fraction of secondary organic carbon (SOC) were highest during the winter smog events. Sulfate, nitrate and SOC that can have long residence times were important species during the smog events suggesting that regional scale sources rather than local sources were important. Five-day backward air trajectory analysis showed that the air parcels during smog events passed through the major industrial areas in China more often than those during non-smog events.  相似文献   

5.
Fine particulate matter (PM2.5) was sampled at 5 Spanish locations during the European Community Respiratory Health Survey II (ECRHS II). In an attempt to identify and quantify PM2.5 sources, source contribution analysis by principal component analysis (PCA) was performed on five datasets containing elemental composition of PM2.5 analysed by ED-XRF. A total of 4–5 factors were identified at each site, three of them being common to all sites (interpreted as traffic, mineral and secondary aerosols) whereas industrial sources were site-specific. Sea-salt was identified as independent source at all coastal locations except for Barcelona (where it was clustered with secondary aerosols). Despite their typically dominant coarse grain-size distribution, mineral and marine aerosols were clearly observed in PM2.5. Multi-linear regression analysis (MLRA) was applied to the data, showing that traffic was the main source of PM2.5 at the five sites (39–53% of PM2.5, 5.1–12.0 μg m−3), while regional-scale secondary aerosols accounted for 14–34% of PM2.5 (2.6–4.5 μg m−3), mineral matter for 13–31% (2.4–4.6 μg m−3) and sea-salt made up 3–7% of the PM2.5 mass (0.4–1.3 μg m−3). Consequently, despite regional and climatic variability throughout Spain, the same four main PM2.5 emission sources were identified at all the study sites and the differences between the relative contributions of each of these sources varied at most 20%. This would corroborate PM2.5 as a useful parameter for health studies and environmental policy-making, owing to the fact that it is not as subject to the influence of micro-sitting as other parameters such as PM10. African dust inputs were observed in the mineral source, adding on average 4–11 μg m−3 to the PM2.5 daily mean during dust outbreaks. On average, levels of Al, Si, Ti and Fe during African episodes were higher by a factor of 2–8 with respect to non-African days, whereas levels of local pollutants (absorption coefficient, S, Pb, Cl) showed smaller variations (factor of 0.5–2).  相似文献   

6.
For over one year, the Environmental Protection Commission of Hillsborough County (EPCHC) in Tampa, Florida, operated two dichotomous sequential particulate matter air samplers collocated with a manual Federal Reference Method (FRM) air sampler at a waterfront site on Tampa Bay. The FRM was alternately configured as a PM2.5, then as a PM10 sampler. For the dichotomous sampler measurements, daily 24-h integrated PM2.5 and PM10–2.5 ambient air samples were collected at a total flow rate of 16.7 l min−1. A virtual impactor split the air into flow rates of 1.67 and 15.0 l min−1 onto PM10–2.5 and PM2.5 47-mm diameter PTFE® filters, respectively. Between the two dichotomous air samplers, the average concentration, relative bias and relative precision were 13.3 μg m−3, 0.02% and 5.2% for PM2.5 concentrations (n=282), and 12.3 μg m−3, 3.9% and 7.7% for PM10–2.5 concentrations (n=282). FRM measurements were alternate day 24-h integrated PM2.5 or PM10 ambient air samples collected onto 47-mm diameter PTFE® filters at a flow rate of 16.7 l min−1. Between a dichotomous and a PM2.5 FRM air sampler, the average concentration, relative bias and relative precision were 12.4 μg m−3, −5.6% and 8.2% (n=43); and between a dichotomous and a PM10 FRM air sampler, the average concentration, relative bias and relative precision were 25.7 μg m−3, −4.0% and 5.8% (n=102). The PM2.5 concentration measurement standard errors were 0.95, 0.79 and 1.02 μg m−3; for PM10 the standard errors were 1.06, 1.59, and 1.70 μg m−3 for two dichotomous and one FRM samplers, respectively, which indicate the dichotomous samplers have superior technical merit. These results reveal the potential for the dichotomous sequential air sampler to replace the combination of the PM2.5 and PM10 FRM air samplers, offering the capability of making simultaneous, self-consistent determinations of these particulate matter fractions in a routine ambient monitoring mode.  相似文献   

7.
Sampling and analysis of carbonaceous compounds in particulate matter presents a number of difficulties related to artefacts during sampling and to the distinction between organic (OC) and elemental carbon (EC) during analysis. Our study reports on a comparative analysis of OC, EC and WSOC (water-soluble organic carbon) concentrations, as well as sampling artefacts, for PM2.5 aerosol in three European cities (Amsterdam, Barcelona and Ghent) representing Southern and Western European urban environments. Comparability of results was ensured by using a single system for sample analysis from the different sites. OC and EC concentrations were higher in the vicinity of roads, thus having higher levels in Amsterdam (3.9–6.7 and 1.7–1.9 μg m−3, respectively) and Barcelona (3.6–6.9 and 1.5–2.6 μg m−3) than in Ghent (2.7–5.4 and 0.8–1.2 μg m−3). A relatively larger influence of secondary organic aerosols (SOA), as deduced from a larger OC/EC ratio, was observed in Ghent. In absolute sense, WSOC concentrations were similar at the three sites (1.0–2.3 μg m−3). Positive artefacts were higher in Southern (11–16% of the OC concentration in Barcelona) than in Western Europe (5–12% in Amsterdam, 5–7% in Ghent). During special episodes, the contribution of carbonaceous aerosols from non-local sources accounted for 67–69% of the OC concentration in Western Europe, and for 44% in Southern Europe.  相似文献   

8.
We present measurements of ammonia (NH3) over a deciduous forest in southern Indiana collected during four field campaigns; two in the spring during the transition to leaf-out and two during the winter. Above canopy NH3 concentrations measured continuously using two Wet Effluent Diffusion Denuders indicate mean concentrations of 0.6–1.2 μg m−3 during the spring and 0.3 μg m−3 during the winter. Measurements suggest that on average the forest act as a sink of NH3, with a representative daily deposition flux of 1.8 mg-NH3 m−2 during the spring. However, on some days during the spring inverted concentration gradients of NH3 were observed resulting in an apparent upward flux of nearly 0.2 mg-NH3 m−2 h−1. Analyses suggest that this apparent emission flux may be due to canopy emission but evaporation of ammonium nitrate particles may also be partly responsible for the observed inverted concentration gradients.  相似文献   

9.
An instrument was developed for semi-continuous measurement of the size-distribution of submicron nitrate, ammonium, sulphate and chloride. Novel in the instrumentation is the size-classification, which is realised with a pre-separator that consists of a set of four parallel impactors. The cut-off diameters of the impactors are at 0.18, 0.32, 0.56 and 1.0 μm. Aerosols smaller than the associated cut-off size pass the respective impactor and arrive in the detector. The manifold with impactors contains two additional lines, one open line and one containing a filter that removes all aerosols. This latter line provides an on-line field-blank. The sample air-flow is automatically switched by wide-bore ball valves to one of the six sampling lines for a period of 20 min; a measuring cycle thus takes 2 h.Down-stream of the pre-separator the sampling and automated on-line analysis of the transmitted aerosol is accomplished with a “MARGA”. In this instrument steam condensation is used to grow the aerosol. The droplets formed are collected in a cyclone that drains to wet-chemical analysis systems. A wet-denuder between pre-separator and collector removes interfering gases, like nitric acid and ammonia. This enables artefact-free and thus representative semi-continuous measurement of the size-distribution of the semi-volatile (ammonium) nitrate.The novel MARGA-sizer was first used in a 1 week field-test. After modifications it was then deployed in a monitoring campaign of 2 months in the summer of 2002, at the top level of the meteo-tower of Cabauw in the centre of the Netherlands. The high location, 200 m, was chosen to obtain data on ammonium nitrate that are minimally affected by surface emissions of ammonia. The data coverage over the period was over 60%; failure of the instrumentation was mainly associated with spells of extreme solar heating of the tower and associated high temperatures inside.The average concentration of nitrate was 2.6 μg m−3, which was very similar to the value interpolated from data in the national network. The mass concentration of submicron nitrate was 2.0 μg m−3, of which 46% was in particles smaller than 0.32 μm. To put this in perspective: the concentration of submicron sulphate was similar to that of nitrate, while 53% was in particles smaller than 0.32 μm. The ion balance showed that the compounds were present as the fully neutralised salts. Quite large diurnal variations were observed for nitrate, with a surprising maximum in the afternoon. The size-distribution of the semi-volatile nitrate was rather constant over a daily cycle.  相似文献   

10.
Fine particle nitrate concentrations were measured at 10-min intervals for approximately 9.5 months beginning on 14 February 2002, at the Baltimore Supersite Ponca St. location using an R&P 8400N semi-continuous monitor. The measurement results were used to characterize seasonal and shorter-term excursions in nitrate concentrations and determine their influence on PM2.5 concentrations. Over the 9.5-month study period, nitrate levels of 1.7±1.6 μg m−3 accounted for 11.4% of the PM2.5 mass. Monthly averages ranged from 0.8 μg m−3 in August to 2.9 μg m−3 in November, and accounted for 4.7–17.3% of monthly PM2.5 mass. Hourly averages, however, were often larger, especially in the colder months, owing to numerous relatively short-term transients, where hourly nitrate concentrations exceeded 5.0 μg m−3. These often occurred along with NOx and ultrafine particle transients during the morning commute hours.A total of 275 short-term transients (31.7% of the total) exceeding 1.0 μg m−3 were identified. These were associated with one of three sets of conditions. The first, most typical (177, i.e. 64.4% of the 275 incidences), is characterized by high NOx typically between 0500 and 0800EST and is attributed to early morning commute traffic activity. The second type occurred during the afternoon due to photochemical activity. The excursions in the afternoon occurred infrequently (only 9.5% of all the observed transients) during the study period and were characterized by less elevated nitrate concentrations than morning and nighttime transients. The third (72, i.e. 26.2% of the 275 transients) occurred at night, typically between 2000EST and 0200EST.Multiple linear regression analysis between nitrate excursions and volume size distributions indicates that particulate nitrate observed is closely related to the near accumulation (0.1–0.2 μm) and droplet modes (0.5–1.0 μm) in the morning hours, and associated with the droplet (0.5–1.0 μm) and coarse modes (1.0–2.5 μm) for nighttime transients, suggesting that processes governing particulate nitrate formation depend on time-of-day.  相似文献   

11.
PM10 aerosols at McMurdo Station, Antarctica were sampled continuously during the austral summers of 1995–1996 and 1996–1997. PM10 (particles with aerodynamic diameters less than 10 μm) mass concentrations at Hut Point, located less than 1 km from downtown McMurdo, averaged 3.4 μg m−3, more than an order of magnitude lower than the USEPA annual average National Ambient Air Quality Standard (NAAQS) of 50 μg m−3. Concentrations of methanesulfonate and nitrate were similar to those measured at other Antarctic coastal sites. Non-sea-salt sulfate (NSS) concentrations on Ross Island were higher than those found at other coastal locations. The average elemental carbon concentration (129 ng m−3) downwind of the station was two orders of magnitude higher than those measured at remote coastal and inland Antarctic sites during summer. Average sulfur dioxide concentrations (746 ng m−3) were 3–44 times higher than those reported for coastal Antarctica. Concentrations of Pb and Zn were 17 and 46 times higher than those reported for the South Pole. A methanesulfonate to biogenic sulfate ratio (R) of 0.47 was derived that is consistent with the proposed temperature dependence of R.  相似文献   

12.
Regular measurements of total mass concentration and mass-size distribution of near-surface aerosols, made using a ten-channel Quartz Crystal Microbalance (qcm) Impactor for the period October 1998–December 1999 at the tropical coastal station Trivandrum (8.5°N, 77°E), are used to study the response of aerosol characteristics to regional mesoscale and synoptic processes. Results reveal that aerosol mass concentrations are generally higher under land breeze conditions. The sea breeze generally has a cleansing effect, depleting the aerosol loading. The continental air (LB regime) is richer in accumulation mode (submicron) aerosols than the marine air. On a synoptic scale, aerosol mass concentration in the submicron mode decreased from an average high value of ∼86 μg m−3 during the dry months (January–March) to ∼11 μg m−3 during the monsoon season (June–September). On the contrary mass concentration in the supermicron mode increased from a low value of ∼15 μg m−3 during the dry months to reach a comparatively high value of ∼35 μg m−3 during April, May. Correspondingly, the effective radius (Reff) increased from a low value of 0.15–0.17 μm to ∼0.3 μm indicating a seasonal change in the size distribution. The mass-size distribution shows mainly three modes, a fine mode (∼0.1 μm); a large mode (∼0.5 μm) and a coarse mode (∼3 μm). The fine mode dominates in winter. In summer the large mode becomes more conspicuous and the coarse mode builds up. The fine mode is highly reduced in monsoon and the large and coarse modes continue to remain high (replenished) so that their relative dominance increases. The size distribution tends to revert to the winter pattern in the post-monsoon season. Accumulation (submicron) aerosols account for ∼98% of the total surface area and ∼70% of the total volume of aerosols during winter. During monsoon, even though they still account for ∼90% of the area, their contribution to the volume is reduced to ∼50%; the coarse aerosols account for the rest.  相似文献   

13.
Direct atmospheric fixed-nitrogen deposition can contribute to eutrophication in coastal and estuarine waters and can be enhanced by heterogeneous reactions between gaseous atmospheric nitrogen species and aerosol sea salt, which increase deposition rates. Size-segregated aerosol samples were collected from two coastal sites: Weybourne, England and Mace Head, Ireland. Major-ion aerosol concentrations were determined and temporal patterns were interpreted with the use of air-mass back trajectories. Low levels of terrestrially derived material were seen during periods of clean, onshore flow, with respective concentration ranges for nitrate and ammonium of 0.47–220 and below detection limit to 340 nmol m−3. Corresponding levels of marine derived material during these periods were high, with sodium concentrations ranging from 39 to 1400 nmol m−3. Highest levels of terrestrially derived material were seen during polluted, offshore flow, where the air had passed recently over strong source regions of the UK and northern Europe, with concentration ranges of nitrate and ammonium of 5.6–790 and 9.7–1000 nmol m−3, respectively. During polluted flow ∼40–60% of the nitrate was found in the coarse mode (>1 μm diameter) and under clean marine conditions almost 100% conversion was seen. In addition, our data suggests strong evidence for dissolution/coagulation processes that also shift nitrate to the coarse mode. Furthermore, such processes are thought also to give rise to the size-shifting of aerosol ammonium, since significant coarse-mode fractions of this species (∼19–45%) were seen at both sites. A comparison of the relative importance of nitrate and ammonium in the overall dry deposition of inorganic fixed-nitrogen at each site indicates that at Weybourne the mass-weighted dry deposition velocity of the latter is around double that seen at Mace Head with its resultant contribution to the overall inorganic nitrogen dry flux exceeding that of nitrate.  相似文献   

14.
A water surface sampler (WSS) was employed in combination with greased knife-edge surface deposition plates (KSSs) to measure the vapor phase deposition rates of PCBs to the sampler at an urban site, Chicago, IL. This sampler employed a water circulation system that continuously removed deposited PCBs. Total (gas+particle) and particulate PCB fluxes were collected with the WSS and KSSs, respectively. Gas phase PCB fluxes were then calculated by subtracting the KSS fluxes (particulate) from the WSS fluxes (gas+particle). The calculated gas phase PCB fluxes averaged 830±910 ng m−2d−1. This flux value is, in general, higher than the fluxes determined using simultaneously measured air–water concentrations in natural waters and is in the absorption direction. This difference is primarily because the PCBs were continuously removed from the WSS water keeping the water PCB concentration near zero.Concurrently, ambient air samples were collected using a modified high volume air sampler. The gas phase PCB concentrations ranged between 1.10 and 4.46 ng m−3 (average±SD, 2.29±1.28 ng m−3). The gas phase fluxes were divided by the simultaneously measured gas phase ambient concentrations to determine the overall gas phase mass transfer coefficients (MTCs) for PCBs. The average gas phase overall MTCs (Kg) for each homolog group ranged between 0.22 and 1.32 cm s−1 (0.54±0.47 cm s−1). The average MTC was in good agreement with those determined using similar techniques.  相似文献   

15.
The present study reports findings on TSP loading in the ambient air of two major cities in Pakistan – Karachi and Islamabad. Data for TSP were collected at one site in Karachi and two in Islamabad between 10 December 1998 and 08 January 1999. This article reports one of the highest TSP loadings recorded so far in any megacity of the world. During the study period, average daily TSP concentrations at the Karachi site ranged from 627 to 938 μg m−3 with a mean of 668 μg m−3. On four occasions TSP concentrations were >1000 μg m−3 (range 1031–1736 μg m−3). At the Islamabad sampling site in close proximity to the city's industrial sector, daily TSP concentrations varied in the range of 428–998 μg m−3 (mean 691 μg m−3). Even at a relatively remote site of the city (Saidpur), TSP loading was high (range 145–448 μg m−3; mean 275 μg m−3). By virtue of the WHO definition, the 24-h average TSP concentrations in a busy commercial site in Karachi and in the vicinity of an industrial sector in Islamabad were in “exceedance” by a factor of 4–8. At Saidpur, the remote site, the 24-h average TSP loading exceeded the WHO guideline of 120 μg m−3 by a factor of 1.2–3.7.  相似文献   

16.
Atmospheric transport of trace elements has been found to be an important pathway for their input to the ocean. TSP, PM10, and PM2.5 aerosol samples were collected over the Northern South China Sea in two cruises in 2003 to estimate the input of aerosol from continent to the ocean. About 23 elements and 14 soluble ions in aerosol samples were measured. The average mass concentration of TSP in Cruise I in January (78 μg m−3) was ∼twice of that in Cruise II in April (37 μg m−3). Together with the crustal component, heavy metals from pollution sources over the land (especially from the industry and automobiles in Guangzhou) were transported to and deposited into the ocean. The atmospheric MSA concentrations in PM2.5 (0.048 μg m−3 in Cruise I and 0.043 μg m−3 in Cruise II) over Northern South China Sea were comparable to those over other coastal regions. The ratio of non-sea-salt (NSS)-sulfate to MSA is 103-655 for Cruise I and 15-440 for Cruise II in PM2.5 samples, which were much higher than those over remote oceans. The estimated anthropogenic sulfate accounts for 83–98% in Cruise I and 63–95% in Cruise II of the total NSS-sulfate. Fe (II) concentration in the aerosols collected over the ocean ranged from 0.1 to 0.9 μg m−3, accounting for 16–82% of the total iron in the aerosol, which could affect the marine biogeochemical cycle greatly.  相似文献   

17.
The average total (wet plus dry) nitrogen deposition to the Tampa Bay Estuary was 7.3 (±1.3) kg-N ha−1 yr−1 or 760 (±140) metric tons-N yr−1 for August 1996–July 1999, estimated as a direct deposition rate to the 104,000-ha water surface. This nitrogen flux estimate accounted for ammonia exchange at the air–sea interface. The uncertainty estimate was based on measurement error. Wet deposition was 56% of the total nitrogen deposition over this period, with an average 0.78 ratio of dry-to-wet deposition. Wet nitrogen deposition rates varied considerably, from near zero to 1.3 kg-N ha−1 month−1. About 40% of the total nitrogen flux occurred during the summer months of June, July and August when rainfall was the highest, except for 1997–1998 when the El Niño phenomenon brought unseasonal rainfall. Ammonia/ammonium contributed to 58%, and nitric acid/nitrate 42%, of the total nitrogen deposition over the 3-yr period. In one summer as waters of Tampa Bay warmed above 28°C and ammonium concentrations reached 0.03 mg l−1, the estimated net flux of ammonia was from the Bay waters to the atmosphere.  相似文献   

18.
Micrometeorological measurements and ambient air samples, analyzed for concentrations of NH3, HNO3, NH4+, and NO3, were collected at an alpine tundra site on Niwot Ridge, Colorado. The measured concentrations were extremely low and ranged between 5 and 70 ng N m−3. Dry deposition fluxes of these atmospheric species were calculated using the micrometeorological gradient method. The calculated mean flux for NH3 indicates a net deposition to the surface and indicates that NH3 contributed significantly to the total N deposition to the tundra during the August–September measurement period. Our pre-measurement estimate of the compensation point for NH3 in air above the tundra was 100–200 ng N m−3; thus, a net emission of NH3 was expected given the low ambient concentrations of NH3 observed. Based on our results, however, the NH3 compensation point at this alpine tundra site appears to have been at or below about 20 ng N m−3. Large deposition velocities (>2 cm s−1) were determined for nitrate and ammonium and may result from reactions with surface-derived aerosols.  相似文献   

19.
《Chemosphere》2013,90(11):1307-1315
This study investigated the presence and distribution of 22 antibiotics, including eight quinolones, nine sulfonamides and five macrolides, in the water, sediments, and biota samples from Baiyangdian Lake, China. A total of 132 samples were collected in 2008 and 2010, and laboratory analyses revealed that antibiotics were widely distributed in the lake. Sulfonamides were the dominant antibiotics in the water (0.86–1563 ng L−1), while quinolones were prominent in sediments (65.5–1166 μg kg−1) and aquatic plants (8.37–6532 μg kg−1). Quinolones (17.8–167 μg kg−1) and macrolides [from below detection limit (BDL) to 182 μg kg−1] were often found in aquatic animals and birds. Salvinia natans exhibited the highest bioaccumulation capability for quinolones among three species of aquatic plants. Geographical differences of antibiotic concentrations were greatly due to anthropogenic activities. Sewage discharged from Baoding City was likely the main source of antibiotics in the lake. Risk assessment of antibiotics on aquatic organisms suggested that algae and aquatic plants might be at risk in surface water, while animals were likely not at risk.  相似文献   

20.
The long-range transported smokes emitted by biomass burning had a strong impact on the PM2.5 mass concentrations in Helsinki over the 12 days period in April and May 2006. To characterize aerosols during this period, the real-time measurements were done for PM2.5, PM2.5–10, common ions and black carbon. Moreover, the 24-h PM1 filter samples were analysed for organic and elemental carbon (OC and EC), water-soluble organic carbon (WSOC), ions and levoglucosan. The Finnish emergency and air quality modelling system SILAM was used for the forecast of the PM2.5 concentration generated by biomass burning. According to the real-time PM2.5 data, the investigated period was divided into four types of PM situations: episode 1 (EPI-1; 25–29 April), episode 2 (EPI-2; 1–5 May), episode 3 (EPI-3; 5–6 May) and a reference period (REF; 24 March–24 April). EPI-3 included a local warehouse fire and therefore it is discussed separately. The PM1 mass concentrations of biomass burning tracers—levoglucosan, potassium and oxalate—increased during the two long-range transport episodes (EPI-1 and EPI-2). The most substantial difference between the episodes was exhibited by the sulphate concentration, which was 4.9 (±1.4) μg m−3 in EPI-2 but only 2.4 (±0.31) μg m−3 in EPI-1 being close to that of REF (1.8±0.54 μg m−3). The concentration of particulate organic matter in PM1 was clearly higher during EPI-1 (11±3.3 μg m−3) and EPI-2 (9.7±4.0 μg m−3) than REF (1.3±0.45 μg m−3). The long-range transported smoke had only a minor impact on the WSOC-to-OC ratio. According to the model simulations, MODIS detected the fires that caused the first set of concentration peaks (EPI-1) and the local warehouse fire (EPI-3), but missed the second one (EPI-2) probably due to dense frontal clouds.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号