首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 812 毫秒
1.
Assessment of environmental and occupational exposure to chemicals can be performed with environmental monitoring (EM) and biological monitoring (BM). Biological monitoring was for a long time considered as a method complementary to environmental monitoring. At present this attitude is changing and in certain areas biological monitoring is applied as the method of choice for exposure and health-risk assessment. This paper examines advantages and disadvantages of those two approaches. In occupational settings environmental monitoring of exposure to VOCs seems to be superior to biological monitoring (possibility of simultaneous determination of components of mixtures, simple interpretation, possibility of evaluation of short-term exposure to local irritants). In the case of this group of compounds BM can be useful in selected cases such as evaluation of dermal absorption or efficiency of protective measures. In the case of metals both forms of monitoring can be used depending on the available methods for interpretation of results. BM of exposure may be considered as superior for evaluating the effects of exposure to lead, cadmium and mercury. However, quantitative evaluation of cancer risk after exposure to arsenic or chromium is possible only on the basis of determination in the air and the use of unit risk values. Both environmental and biological monitoring are useful for evaluation of occupational and environmental exposure to polycyclic aromatic hydrocarbons (PAHs). In certain areas such as evaluation of exposure to external tobacco smoking, cytostatic drugs, and pesticides, biological monitoring is the method of choice used for individual exposure assessment or tracing the trends of environmental exposure.  相似文献   

2.
Exposure to perchlorethylene, especially for dry cleaning workers and for people living near dry cleaning shops, could lead to several diseases and disorders. This study examines the value of solid-phase microextraction (SPME) for sampling perchlorethylene in the atmosphere of dry cleaning shops. Carboxen/polydimethylsiloxane (CAR/PDMS) in 0.5-cm retracted mode was selected. There were no significant differences between sampling rates at different temperatures (range of 20 to 30 °C) and air velocities (2 to 50 cm/s). On the opposite, relative humidity (RH) had a significant effect on sampling rates. Method reproducibility was realized in the laboratory and field conditions and was 6.2 % and 7 to 11 %, respectively. Repeatability was also determined as 8.9 %. Comparison of the results according to the American Industrial Hygiene Association exposure assessment strategy showed the SPME sampler yields more conservative results in comparison with traditional standard method.  相似文献   

3.
UV-curable acrylates are used increasingly for coating wood surfaces in the furniture industry. One of the active components, tripropylene glycol diacrylate (TPGDA), is known to be both an allergen and irritant to the skin. Methods to measure dermal exposure to skin irritants and allergens, such as acrylates, are insufficient for exposure assessment and there is none for this compound. The aim of this investigation was to develop a skin and surface sampling method, based on tape stripping, and a gas chromatographic method for quantitative analysis for assessing occupational skin exposure to multifunctional acrylates. Twelve adhesives were tested for their efficiency to remove TPGDA and UV-coating from a glass surface, the skin of guinea pigs and human volunteers employing the tape-stripping method in order to find the best performing tape. Variables that affect removal efficiency such as the applied dose and its retention time on the skin, tape adhesion time on the skin, and the number of strippings required to detect the contaminant from the skin were studied. Fixomull tape performed the best during sampling and analysis and had the most consistent removal efficiencies for the studied substances. The average removal efficiency with a single stripping at the 2 microliters TPGDA exposed skin sites was 85% (RSD = 14.1), and for UV-resin exposed sites 63% (RSD = 20.2). The results indicated that this method can be used for measuring dermal exposure to multifunctional acrylates efficiently, accurately, and economically. This method provides a sensitive and powerful tool for the assessment of dermal exposure to multifunctional acrylates both from the skin and from other contaminated surfaces in occupational field settings.  相似文献   

4.
Beryllium is widely used in industry for its unique properties; however, occupational exposure to beryllium particles can cause potentially fatal disease. Consequently, exposure limits for beryllium particles in air and action levels on surfaces have been established to reduce exposure risks for workers. Field-portable monitoring methods for beryllium are desired in order to facilitate on-site measurement of beryllium in the workplace, so that immediate action can be taken to protect human health. In this work, a standardized, portable fluorescence method for the determination of trace beryllium in workplace samples, i.e., air filters and dust wipes, was validated through intra- and inter-laboratory testing. The procedure entails extraction of beryllium in 1% ammonium bifluoride (NH(4)HF(2), aqueous), followed by fluorescence measurement of the complex formed between beryllium ion and hydroxybenzoquinoline sulfonate (HBQS). The method detection limit was estimated to be less than 0.02 microg Be per air filter or wipe sample, with a dynamic range up to greater than 10 microg. The overall method accuracy was shown to satisfy the accuracy criterion (A< or = +/-25%) for analytical methods promulgated by the US National Institute for Occupational Safety and Health (NIOSH). Interferences from numerous metals tested (in >400-fold excess concentration compared to that of beryllium) were negligible or minimal. The procedure was shown to be effective for the dissolution and quantitative detection of beryllium extracted from refractory beryllium oxide particles. An American Society for Testing and Materials (ASTM) International voluntary consensus standard based on the methodology has recently been published.  相似文献   

5.
Personal and area samples for airborne lead were taken at a lead mine concentrator mill, and at a lead-acid battery recycler. Lead is mined as its sulfidic ore, galena, which is often associated with zinc and silver. The ore typically is concentrated, and partially separated, on site by crushing and differential froth flotation of the ore minerals before being sent to a primary smelter. Besides lead, zinc and iron are also present in the airborne dusts, together with insignificant levels of copper and silver, and, in one area, manganese. The disposal of used lead-acid batteries presents environmental issues, and is also a waste of recoverable materials. Recycling operations allow for the recovery of lead, which can then be sold back to battery manufacturers to form a closed loop. At the recycling facility lead is the chief airborne metal, together with minor antimony and tin, but several other metals are generally present in much smaller quantities, including copper, chromium, manganese and cadmium. Samplers used in these studies included the closed-face 37 mm filter cassette (the current US standard method for lead sampling), the 37 mm GSP or "cone" sampler, the 25 mm Institute of Occupational Medicine (IOM) inhalable sampler, the 25 mm Button sampler, and the open-face 25 mm cassette. Mixed cellulose-ester filters were used in all samplers. The filters were analyzed after sampling for their content of the various metals, particularly lead, that could be analyzed by the specific portable X-ray fluorescence (XRF) analyzer under study, and then were extracted with acid and analyzed by inductively coupled plasma optical emission spectroscopy (ICP-OES). The 25 mm filters were analyzed using a single XRF reading, while three readings on different parts of the filter were taken from the 37 mm filters. For lead at the mine concentrate mill, all five samplers gave good correlations (r2 > 0.96) between the two analytical methods over the entire range of found lead mass, which encompassed the permissible exposure limit of 150 mg m(-3) enforced in the USA by the Mine Safety and Health Administration (MSHA). Linear regression on the results from most samplers gave almost 1 ratio 1 correlations without additional correction, indicating an absence of matrix effects from the presence of iron and zinc in the samples. An approximately 10% negative bias was found for the slope of the Button sampler regression, in line with other studies, but it did not significantly affect the accuracy as all XRF results from this sampler were within 20% of the corresponding ICP values. As in previous studies, the best results were obtained with the GSP sampler using the average of three readings, with all XRF results within 20% of the corresponding ICP values and a slope close to 1 (0.99). Greater than 95% of XRF results were within 20% of the corresponding ICP values for the closed-face 37 mm cassette using the OSHA algorithm, and the IOM sampler using a sample area of 3.46 cm2. As in previous studies, considerable material was found on the interior walls of all samplers that possess an internal surface for deposition, at approximately the same proportion for all samplers. At the lead-acid battery recycler all five samplers in their optimal configurations gave good correlations (r2 > 0.92) between the two analytical methods over the entire range of found lead mass, which included the permissible exposure limit enforced in the USA by the Occupational Safety and Health Administration (OSHA). Linear regression on the results from most samplers gave almost 1 ratio 1 correlations (except for the Button sampler), indicating an absence of matrix effects from the presence of the smaller quantities of the other metals in the samples. A negative bias was found for the slope of the button sampler regression, in line with other studies. Even though very high concentrations of lead were encountered (up to almost 6 mg m(-3)) no saturation of the detector was observed. Most samplers performed well, with >90% of XRF results within +/- 25% of the corresponding ICP results for the optimum configurations. The OSHA algorithm for the CFC worked best without including the back-up pad with the filter.  相似文献   

6.
A field study was conducted with the goal of comparing the performance of three recently developed or modified sampling and analytical methods for the determination of airborne hexavalent chromium (Cr(VI)). The study was carried out in a hard chrome electroplating facility and in a jet engine manufacturing facility where airborne Cr(VI) was expected to be present. The analytical methods evaluated included two laboratory-based procedures (OSHA Method ID-215 and NIOSH Method 7605) and a field-portable method (NIOSH Method 7703). These three methods employ an identical sampling methodology: collection of Cr(VI)-containing aerosol on a polyvinyl chloride (PVC) filter housed in a sampling cassette, which is connected to a personal sampling pump calibrated at an appropriate flow rate. The basis of the analytical methods for all three methods involves extraction of the PVC filter in alkaline buffer solution, chemical isolation of the Cr(VI) ion, complexation of the Cr(VI) ion with 1,5-diphenylcarbazide, and spectrometric measurement of the violet chromium diphenylcarbazone complex at 540 nm. However, there are notable specific differences within the sample preparation procedures used in three methods. To assess the comparability of the three measurement protocols, a total of 20 side-by-side air samples were collected, equally divided between a chromic acid electroplating operation and a spray paint operation where water soluble forms of Cr(VI) were used. A range of Cr(VI) concentrations from 0.6 to 960 microg m(-3), with Cr(VI) mass loadings ranging from 0.4 to 32 microg, was measured at the two operations. The equivalence of the means of the log-transformed Cr(VI) concentrations obtained from the different analytical methods was compared. Based on analysis of variance (ANOVA) results, no statistically significant differences were observed between mean values measured using each of the three methods. Small but statistically significant differences were observed between results obtained from performance evaluation samples for the NIOSH field method and the OSHA laboratory method.  相似文献   

7.
The purpose of this study was to develop a sensitive and specific method for quantifying dermal exposure to the resin acids 7-oxodehydroabietic acid (7-OXO), dehydroabietic acid (DHAA), abietic acid (AA), and pimaric acid (PA). In addition the method was evaluated in occupational settings during production of wood pellets. Tape-strips were spiked with the substances to evaluate the recovery of the acids from the tape. The removal efficiency of the tape was assessed by tape-stripping a specified area on a glass plate spiked with resin acids. The recovery of the acids from human skin in vivo was evaluated by applying acids in methanol onto the skin of volunteers. Occupational dermal exposure to the resin acids was assessed by tape-stripping the skin of workers involved in the production of wood pellets. The resin acids were analyzed by liquid chromatography mass spectrometry (LC-MS). The limit of detection was 15 pg (7-OXO), 150 pg (DHAA), 285 pg (AA) and 471 pg (PA) per injection. The recovery from spiked tapes was in general 100%. The removal efficiency of the tape was 48-101%. Recovery tests from human skin in vivo showed a mean recovery of 27%. Quantifiable amounts of resin acids were observed on four different skin areas with an increase in exposure during a work shift. This study shows that occupational dermal exposure to resin acids can be assessed by tape-stripping and quantified by LC-MS.  相似文献   

8.
Occupational exposure to benzene was measured in two gasoline marketing terminals and five major refineries in Singapore. A total of 280 workers were monitored over two years. This assessment was carried out with two primary objectives: (1) To find out the extent of occupational exposure to benzene in the petroleum industry in Singapore, (2) To identify suitable biomarkers for monitoring of low levels of benzene exposure. The exposure was measured in five different categories of petroleum and petrochemical workers, i.e., truck drivers, despatch assistant, process operators, oil movements operators and laboratory technicians. The results revealed wide variations in exposure, from 0.01 to 13.6 ppm for personal time weighted average (TWA) exposure over the whole workshift. The exposure of truck drivers appeared to be the highest, with geometric mean (GM) of 1.98 ppm (ranged from 0.25 to 13.6 ppm). The average benzene exposure for process operators was relative low with a GM of 0.04 ppm. Lowest benzene exposure was found in the laboratory technicians, with a GM of 0.02 ppm. As cigarette smoking is known to affect metabolism of benzene, data analyses on the relationships with environmental exposure were conducted only on the 190 nonsmokers. The results showed that urinary trans, trans-muconic acid (ttMA), unmetabolized benzene in urine (UBZ) and benzene in blood (BBZ) were better biomarkers for low level benzene exposure as compared to urinary phenolic metabolites in urine, such as hydroquinone, phenol and catechol.  相似文献   

9.
采用固相微萃取法富集,气相色谱-质谱联用法定性和定量测定饮用水中致嗅物质土嗅素和2-甲基异茨醇。研究并讨论优化了纤维头的类型、盐的种类和浓度、温度、萃取时间等因素对异味化合物萃取量的影响。土嗅素和2-甲基异茨醇的检出限分别为1.02、2.13 ng/L,相对标准偏差分别为4.96%、7.74%。2种异味化合物在5~1 000 ng/L的范围内线性关系良好,相关系数均大于0.985。因此,用该方法能够很好地分析水中痕量的异味化合物。  相似文献   

10.
Two carbon analysis methods are currently being applied to the occupational monitoring of diesel particulate matter. Both methods are based on thermal techniques for the determination of organic and elemental carbon. In Germany, method ZH 1/120.44 has been published. This method, or a variation of it, is being used for compliance measurements in several European countries, and a Comité Européen de Normalization Working Group was formed recently to address the establishment of a European measurement standard. In the USA, a 'thermal-optical' method has been published as Method 5040 by the National Institute for Occupational Safety and Health. As with ZH 1/120.44, organic and elemental carbon are determined through temperature and atmosphere control, but different instrumentation and analysis conditions are used. Although the two methods are similar in principle, they gave statistically different results in a previous interlaboratory comparison. Because different instruments and operating conditions are used, between-method differences can be expected in some cases. Reasonable agreement is expected when the sample contains no other (i.e., non-diesel) sources of carbonaceous particulate and the organic fraction is essentially removed below about 500 degrees C. Airborne particulate samples from some mines may meet these criteria. Comparison data on samples from mines are important because the methods are being applied in this workplace for occupational monitoring and epidemiological studies. In this paper, results of a recent comparison on samples collected in a Canadian mine are reported. As seen in a previous comparison, there was good agreement between the total carbon results found by the two methods, with ZH 1/120.44 giving about 6% less carbon than Method 5040. Differences in the organic and elemental carbon results were again seen, but they were much smaller than those obtained in the previous comparison. The relatively small differences in the split between organic and elemental carbon are attributed to the different thermal programs used.  相似文献   

11.
The interrelationships between ventilation rate, indoor air quality, and energy consumption in operation rooms at rest are yet to be understood. We investigate the effect of ventilation rate on indoor air quality indices and energy consumption in ORs at rest. The study investigates the air temperature, relative humidity, concentrations of carbon dioxide, particulate matter (PM), and airborne bacteria at different ventilation rates in operation rooms at rest of a medical center. The energy consumption and cost analysis of the heating, ventilating, and air conditioning (HVAC) system in the operation rooms at rest were also evaluated for all ventilation rates. No air-conditioned operation rooms had very highest PM and airborne bacterial concentrations in the operation areas. The bacterial concentration in the operation areas with 6–30 air changes per hour (ACH) was below the suggested level set by the United Kingdom (UK) for an empty operation room. A 70% of reduction in annual energy cost by reducing the ventilation rate from 30 to 6 ACH was found in the operation rooms at rest. Maintenance of operation rooms at ventilation rate of 6 ACH could save considerable amounts of energy and achieve the goal of air cleanliness.  相似文献   

12.
Occupational sampling and analysis for multiple elements is generally approached using various approved methods from authoritative government sources such as the National Institute for Occupational Safety and Health (NIOSH), the Occupational Safety and Health Administration (OSHA) and the Environmental Protection Agency (EPA), as well as consensus standards bodies such as ASTM International. The constituents of a sample can exist as unidentified compounds requiring sample preparation to be chosen appropriately, as in the case of beryllium in the form of beryllium oxide (BeO). An interlaboratory study was performed to collect analytical data from volunteer laboratories to examine the effectiveness of methods currently in use for preparation and analysis of samples containing calcined BeO powder. NIST SRM(?) 1877 high-fired BeO powder (1100 to 1200 °C calcining temperature; count median primary particle diameter 0.12 μm) was used to spike air filter media as a representative form of beryllium particulate matter present in workplace sampling that is known to be resistant to dissolution. The BeO powder standard reference material was gravimetrically prepared in a suspension and deposited onto 37 mm mixed cellulose ester air filters at five different levels between 0.5 μg and 25 μg of Be (as BeO). Sample sets consisting of five BeO-spiked filters (in duplicate) and two blank filters, for a total of twelve unique air filter samples per set, were submitted as blind samples to each of 27 participating laboratories. Participants were instructed to follow their current process for sample preparation and utilize their normal analytical methods for processing samples containing substances of this nature. Laboratories using more than one sample preparation and analysis method were provided with more than one sample set. Results from 34 data sets ultimately received from the 27 volunteer laboratories were subjected to applicable statistical analyses. The observed performance data show that sample preparations using nitric acid alone, or combinations of nitric and hydrochloric acids, are not effective for complete extraction of Be from the SRM 1877 refractory BeO particulate matter spiked on air filters; but that effective recovery can be achieved by using sample preparation procedures utilizing either sulfuric or hydrofluoric acid, or by using methodologies involving ammonium bifluoride with heating. Laboratories responsible for quantitative determination of Be in workplace samples that may contain high-fired BeO should use quality assurance schemes that include BeO-spiked sampling media, rather than solely media spiked with soluble Be compounds, and should ensure that methods capable of quantitative digestion of Be from the actual material present are used.  相似文献   

13.
Portable X-ray fluorescence (XRF) technology may provide faster turn-around without compromising accuracy when assessing personal exposures to metals such as lead, but it has only been tested in limited field environments. This study is part of a series, where various types of sampler are used to collect airborne lead in different environments for presentation to a portable XRF analyzer. In this case personal samples were taken at a manufacturer of solder alloys consisting mainly of lead and tin, using the closed-face 37 mm cassette (CFC), the 37 mm GSP or "cone" sampler, the 25 mm Institute of Occupational Medicine (IOM) inhalable sampler, the 25 mm button sampler, and the open-face 25 mm cassette. Mixed cellulose-ester filters were used in all samplers. Following XRF analysis the samples were extracted with acid and analyzed by inductively coupled plasma optical emission spectroscopy (ICP). The internal surfaces of CFC's and 25 mm open-face cassettes were also wiped, and the wipes analyzed for lead to assess wall-losses in these two samplers. Analysis of all elements present is useful to ascertain contributions to matrix interference effects. In addition to lead, other metals such as tin, copper, iron, silver, cadmium and antimony were also detected in some or all of the samples by ICP analysis, but only copper and iron could be determined using the XRF analyzer under test. After the removal of a few outliers, all five samplers gave good correlations (r(2) > 0.9) between the two analytical methods over the entire range of found lead mass, which encompassed both the action level and the permissible exposure limit enforced in the USA by the Occupational Safety and Health Administration (OSHA). Linear regression on the results from most samplers gave almost 1 ratio 1 correlations without additional correction, indicating an absence of matrix effects, particularly from tin, which was the most common element after lead. The average of three XRF readings across filters from the GSP samplers gave the best results with 96.7% of results within +/-25% and 100% within +/-30% of the associated ICP values. Using the center reading only was almost as good with 90.0% of results within +/-25% and 96.7% within +/-30% of the associated ICP values, and results can be obtained faster with a single reading. The use of an algorithm developed by OSHA for three readings from the CFC filter samples gave the next best results with 93.3% of XRF results within +/-25% of the corresponding ICP values. However, analysis of wipes from the interior of the cassettes indicated a substantial loss of sample to the walls, and even larger wall-losses were encountered in the 25 mm open-face cassette. Neither this latter sampler nor the IOM or button sampler met the 95% criterion, even for +/-30% accuracy.  相似文献   

14.
The present paper reports on a rapid method for the analysis of gaseous emissions from ceramic industry, based on ion mobility spectrometry (IMS) as a means for on-site monitoring of volatile organic compounds (VOCs) produced during tile baking. IMS was calibrated with a set of reference compounds (i.e. ethyl acetate, ethanol, ethylene glycol, diethylene glycol, acetaldehyde, formaldehyde, 2-methyl-1,3-dioxolane, 2,2-dimethyl-1,3-dioxolane, 1,3-dioxolane, 1,4-dioxane, benzene, toluene, cyclohexane, acetone, acetic acid) via air-flow permeation. The technique was tested on a laboratory-scale kiln and tiles prepared with selected glycol- and resin-based additives. Finally, the analytical method was applied to emissions from two industries in the Modena (Italy) ceramic area. The results of all experimental phases were compared to those obtained by solid phase micro-extraction/gas chromatography/mass spectrometry (SPME/GC/MS). IMS showed potential as a real-time monitoring device for quality assessment in ceramic industry emissions. IMS spectra, SPME/GC/MS data, relationship between additives/baking conditions and produced VOCs and advantages and limitations of both techniques will be discussed.  相似文献   

15.
Vehicular traffic is one of the main sources of antimony in highly populated urban areas like Buenos Aires where an overall traffic density of 1 500 000 vehicles per day (corresponding to 7500 vehicles km(-2)) is estimated. In this context, a study was undertaken to ascertain the levels of Sb and other traffic-related elements (TRE) in the atmosphere of this city. To this end, sixty-seven samples of PM-10 particulate matter were collected during eight days in nine representative sampling sites located downtown Buenos Aires and spread over an area of about 30 km2. The collection of particulate matter was performed on ash-free glass-fibre filters using high volume samplers with PM-10 sampling heads. A combination of aqua regia and perchloric acid was used for leaching metals from filters. The resulting solutions were evaporated and then diluted with 0.1 mol l(-1) HCl. Antimony was determined by inductively coupled plasma-quadrupole mass spectrometry (ICP-QMS) at ng g(-1) levels. Concentrations of Sb varied from 12.9 +/- 0.9 to 375 +/- 23 microg g(-1)(equivalent to 0.87 +/- 0.06 to 15.3 +/- 0.8 ng m(-3)). Statistical analysis was performed on the data set including the measured PM-10 mass and Sb concentrations for the monitored period. Correlations of Sb with other TRE namely, Cu and Mo were also assessed. The highest concentrations of Sb were detected at two sites (Hospital Alemán and Casa Rapallini) located in streets with traffic consisting mostly of passenger cars and showing a "stop-and-go" pattern in peak hours. Antimony levels in the Buenos Aires PM-10 are by far below the level of 0.5 mg m(-3)(for an 8 hour workday, 40 hour work week) set by the US Occupational Safety and Health Administration (OSHA) for occupational exposure. However, monitoring of Sb and other TRE should be carried out in a systematic fashion to detect the possibility of increases in from the present levels.  相似文献   

16.
The study on the performance of a fluorinated polyaniline (PANI) as a fiber coating for solid-phase microextraction (SPME) had been reported and 16 polycyclic aromatic hydrocarbons (PAHs) were selected to evaluate the performance of this fiber. Various parameters including sample volume, extraction temperature, time of desorption and extraction, pH and ionic strength were investigated intensively. A direct comparison between PANI-SPME fiber and commercial fiber was conducted. The results showed that the PANI-SPME coating had high affinity towards target compounds and the proposed method was successfully applied for the detection of real samples: rainfall and Taihu Lake water collected from Southern China. The whole PANI-SPME-GC method offers acceptable accuracy, precision and sensitivity and low detection limits, which is applicable to monitor trace levels of PAHs in real water bodies.  相似文献   

17.
Exposure to vapours of volatile chemicals is a major occupational and environmental health concern. Toxicity testing of volatile organic compounds (VOCs) has always faced significant technological problems due to their high volatility and/or low solubility. The aim of this study was to develop a practical and reproducible in vitro exposure technique for toxicity testing of VOCs. Standard test atmospheres of xylene and toluene were generated in glass chambers using a static method. Human cells including: A549-lung derived cell lines, HepG2-liver derived cell lines and skin fibroblasts, were grown in porous membranes and exposed to various airborne concentrations of selected VOCs directly at the air/liquid interface for 1 h at 37 degrees C. Cytotoxicity of test chemicals was investigated using the MTS (3-(4,5-dimethylthiazol-2-yl)-5-(3-carboxymethoxyphenyl)-2-(4-sulfophenyl)-2H-tetrazolium) and NRU (neutral red uptake) assays following 24 h incubation. Airborne IC(50) (50% inhibitory concentration) values were determined using dose response curves for xylene (IC(50)=5350+/- 328 ppm, NRU; IC(50)=5750+/- 433 ppm, MTS in skin fibroblast) and toluene (IC(50)=0 500+/- 527 ppm, NRU; IC(50)=11,200 +/- 1,044 ppm, MTS in skin fibroblast). Our findings suggest that static direct exposure at the air/liquid interface is a practical and reproducible technique for toxicity testing of VOCs. Further, this technique can be used for inhalational and dermal toxicity studies of volatile chemicals in vitro as the exposure pattern in vivo is closely simulated by this method.  相似文献   

18.
A number of methods are used to assess exposure to high-molecular weight allergens. In the occupational setting, airborne dust is often collected on filters using pumps, the filters are eluted and allergen content in the eluate analysed using immunoassays. Collecting inhalable dust using person-carried pumps may be considered the gold standard. Other allergen sampling methods are available. Recently, a method that collects nasally inhaled dust on adhesive surfaces within nasal samplers has been developed. Allergen content can be analysed in eluates using sensitive enzyme immunoassays, or allergen-bearing particles can be immunostained using antibodies, and studied under the microscope. Settling airborne dust can be collected in petri dishes, a cheap and simple method that has been utilised in large-scale exposure studies. Collection of reservoir dust from surfaces using vacuum cleaners with a dust collector is commonly used to measure pet or mite allergens in homes. The sampling methods differ in properties and relevance to personal allergen exposure. Since methods for all steps from sampling to analysis differ between laboratories, determining occupational exposure limits for protein allergens is today unfeasible. A general standardisation of methods is needed.  相似文献   

19.
The aim of this study was to estimate mite antigen exposure in farming environments by passive sampling of airborne dust. Antigen concentrations were measured with enzyme immunoassays specific for three storage mites (SM): Acarus siro, Lepidoglyphus destructor, Tyrophagus putrescentiae and the house dust mite (HDM) Dermatophagoides pteronyssinus. Dust samples were collected with electrostatic dust fall collectors (EDCs) in three different areas of cattle farms. EDCs were placed in cow stables (working area), in changing rooms (transit area) and in different rooms of farmer dwellings (living area). Mite concentrations in the living area of farm homes were compared to those of urban homes. In dust samples from stables, antigens of all four mite species could be detected. The highest exposure level was to L. destructor (median 56.7 μg/m(2)), the lowest to A. siro (median 14.4 μg/m(2)). Mite concentrations of different species showed no correlation within the cow stables. In comparison to stables, the median mite concentrations in farm homes were significantly lower, ranging from below the detection limit to 1.5 μg/m(2). Antigens of SM were predominantly found in changing rooms and kitchens, and HDM antigens were mainly detected in bedrooms. Antigens of all mites were measured the least often in living rooms. T. putrescentiae was the most prevalent mite in all room types, and the exposure levels correlated strongly between different rooms. The number of SM positive samples in farm homes was considerably higher than in urban homes, while the percentage of HDM positive samples did not differ significantly.  相似文献   

20.
Portable X-ray fluorescence (XRF) technology may provide faster turn-around without compromising accuracy when assessing personal exposures to metals such as lead, but it has only been tested in limited field environments. This study is part of a series, where different sampler types are used to collect airborne lead in different environments for presentation to a portable XRF analyzer. In this case personal samples were taken at a bronze foundry where lead is added to an alloy of copper, zinc and iron to improve casting, using the closed-face 37 mm cassette, the 37 mm GSP or "cone" sampler, the 25 mm Institute of Occupational Medicine (IOM) inhalable sampler, the 25 mm Button sampler, and the open-face 25 mm cassette. Mixed cellulose-ester filters were used in all samplers. Following XRF analysis the samples were extracted with acid and analyzed by inductively coupled plasma optical emission spectroscopy (ICP). For lead, all five samplers gave correlations (r(2)) greater than 0.9 between the two analytical methods over the entire range of found lead mass, which encompassed both the action level and the permissible exposure limit enforced in the USA by the Occupational Safety and Health Administration (OSHA). However, a correction was required to adjust linear regression trendlines to give a 1 : 1 correlation for the average of three readings across the GSP sampler, and a similar correction was required for the single readings from the IOM sampler and the 25 mm filter cassette. The bias possibly is due to interference from other metals, possibly copper which can absorb the fluorescent radiation of lead. In the case of the Button sampler, the bias is larger, indicating a further source of error, perhaps due to the thickness of the deposit. However, in all cases, correction of the lead results did not greatly affect the overall percentage of samples where the XRF result was within 25% of the ICP result, although it did improve the overall accuracy of the results. The GSP, IOM and Button samplers are suitable candidates for further evaluation as compatible with on-site XRF analysis for lead and other metals. It is important to check carefully factory pre-set instrument calibrations, as a bias in the calibration for copper was observed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号