Recent catastrophic industrial accidents have left the public wary of most industrial facilities. Fearing illness and death from toxic releases, the public has opposed siting hazardous waste facilities in their locale. Associated with these concerns are fears of declining property values and a perceived reduction in the quality of life for a community. Recent political actions stemming from these fears have made siting these facilities an extremely unpopular and expensive process.

This paper presents a systematic, phased approach for performing a reliability and hazards analysis of a hazardous waste facility design. It also demonstrates how the results of a risk analysis can present an accurate "risk picture" of the facility for use in alleviating public fears. A typical analysis is outlined and methods that can be used to convey to the public the results of this type of risk analysis are explored.  相似文献   

2.
Environmental Science and Pollution Research - Chlorinated disinfectants are widely used in hospitals, COVID-19 quarantine facilities, households, institutes, and public areas to combat the spread...  相似文献   

3.
污水处理一体化装置的研究现状与展望   总被引:1,自引:0,他引:1  
污水处理一体化装置具有投资省、占地少、能耗低、处理效果好及管理简便等优点,是现代污水处理的新方向,有着广阔的应用前景。本文结合几种典型的污水处理工艺对污水处理一体化装置进行了概括性的介绍与展望。  相似文献   

4.
BACKGROUND, AIMS AND SCOPE: Composting facilities are known to release odorous volatiles due to biodegradation of municipal waste and plant residues. Although odour perception and its grading is influenced by experience, attitude and adaptation, these emissions have created a lack of acceptance for residents in the vicinity of composting facilities. Enclosure of compost pile halls, ventilation systems and biofilters are often insufficient to minimise the burden of compost-derived compounds in the air. Moreover, economic considerations forced smaller communities to establish less sophisticated facilities with open storage areas and other relevant sources for wind-borne dispersal of bioaerosols. Aim of the present study was to characterise the immission and dispersal of microbial volatiles (MVOC) and, besides, to find coincidences between MVOC and compost odour. METHODS: In the course of this study, the surroundings of two composting facilities, differing in their type of process engineering, were investigated for emission of volatiles in the environment. Both microbially and plant-derived substances were assessed, several of which have low odour thresholds. Air samples were taken in distances ranging from 50 to 800 m in a downwind direction from each facility. RESULTS AND DISCUSSION: Compost-derived and microbial volatile organic compounds (MVOC) were found at distances of up to 800 m from the composting facilities. Terpenes like alpha-pinene, camphene and camphor were the dominant compounds and coincided with typical compost odour, whereas several typical MVOC were not found at greater distances. The terpenes in combination with certain MVOC may play an important role in the perception of compost odour. Exposure concentrations were not of toxicological relevance, but sensory irritation and psychohygienic effects due to an annoyance potential of such compounds should not be dismissed. RECOMMENDATIONS AND OUTLOOK: Although terpenes are generally associated with pleasant odour characteristics, they seemed to contribute to malodours in a mixture with other VOC, in this context of volatile waste from compost facilities. Malodorous emissions from biowaste have to be considered as sources of health complaints and the investigation of mixtures of compost-derived volatiles is still inevitable. Exposure levels have to be discussed taking VOC mixtures into account. Within composting facilities, technical devices have to be improved to minimise dispersal of volatiles to prevent residents from immissions eventually causing health complaints.  相似文献   

5.
Environmental Science and Pollution Research - Sustainable long-term solutions to managing tailings storage facilities (TSFs) are integral for mines to operate in a safe and environmentally...  相似文献   

6.
Novel aerial methane (CH4) detection technologies were used in this study to identify anomalously high-emitting oil and gas (O&G) facilities and to guide ground-based “leak detection and repair” (LDAR) teams. This approach has the potential to enable a rapid and effective inspection of O&G facilities under voluntary or regulatory LDAR programs to identify and mitigate anomalously large CH4 emissions from a disproportionately small number of facilities. This is the first study of which the authors are aware to deploy, evaluate, and compare the CH4 detection volumes and cost-effectiveness of aerially guided and purely ground-based LDAR techniques. Two aerial methods, the Kairos Aerospace infrared CH4 column imaging and the Scientific Aviation in situ aircraft CH4 mole fraction measurements, were tested during a 2-week period in the Fayetteville Shale region contemporaneously with conventional ground-based LDAR. We show that aerially guided LDAR can be at least as cost-effective as ground-based LDAR, but several variable parameters were identified that strongly affect cost-effectiveness and which require field research and improvements beyond this pilot study. These parameters include (i) CH4 minimum dectectable limit of aerial technologies, (ii) emission rate size distributions of sources, (iii) remote distinction of fixable versus nonfixable CH4 sources (“leaks” vs. CH4 emissions occurring by design), and (iv) the fraction of fixable sources to total CH4 emissions. Suggestions for future study design are provided.

Implications: Mitigation of methane leaks from existing oil and gas operations currently relies on on-site inspections of all applicable facilities at a prescribed frequency. This approach is labor- and cost-intensive, especially because a majority of oil and gas–related methane emissions originate from a disproportionately small number of facilities and components. We show for the first time in real-world conditions how aerial methane measurements can identify anomalously high-emitting facilities to enable a rapid, focused, and directed ground inspection of these facilities. The aerially guided approach can be more cost-effective than current practices, especially when implementing the aircraft deployment improvements discussed here.  相似文献   


7.
Fixed-roof tanks are used extensively at manufacturing, waste management, and other facilities to store or process liquids containing volatile organic compounds. Federal and state air standards require the control of organic air emissions from many of these tanks. A common practice used for some fixed-roof tanks that are required to use controls is to vent the tank through an activated carbon canister. When organic vapors are adsorbed on activated carbon, heat is released. Under certain conditions, the temperature of the carbon bed can increase to a level at which the carbon or organic vapors spontaneously ignite, starting a fire in the carbon bed. Bed fires in carbon canisters are not uncommon and can present a significant safety hazard at facilities if proper safety measures are not implemented. This article discusses how carbon adsorber bed fires occur and presents general guidance on safety measures for carbon canisters installed on fixed-roof tanks to reduce the likelihood of a carbon bed fire and to minimize the impact in the event of a fire.  相似文献   

8.
铀尾矿对地下水的环境影响研究   总被引:1,自引:0,他引:1  
在越来越多的铀矿冶场面临退役的情况下,有关铀废石、尾矿的环境影响研究日益受到人们的重视并成为铀矿冶场退役环境影响评价的重要组成部分.本文在广泛搜集国内外有关研究资料的基础上,对前人所做的工作进行了总结,指出了目前研究中存在的问题和未来研究发展的方向.  相似文献   

9.
Selection of acceptable sites for industrial facilities, especially hazardous waste management facilities, can be made using a relatively new technique referred to as “fuzzy set analysis.” The methodology presented is applicable to multiple alternative decision making, when criteria are of unequal importance, and is based on the concept of establishing a subjective value for each alternative according to each criterion, and then raising the subjective value to a power commensurate with the relative importance of the criterion. This exponential weight is calculated on the basis of a preferential analysis of criteria comparisons. Apart from the ranking of the alternatives, fuzzy set analysis provides a quantitative representation of the community opinion of the order of importance of the criteria, regardless of the sites being considered. Based on the importance factors averaged from a cross section of the community, public concern could also be ranked.  相似文献   

10.
All U.S. Department of Defense (DoD) facilities are required under Executive Order (EO) 13148, "Greening the Government through Leadership in Environmental Management," to establish quality-based environmental management systems (EMSs) that support environmental decision-making and verification of continuous environmental improvement by December 31, 2005. Compliance with EO 13148 as well as other federal, state, and local environmental regulations places a significant information management burden on DoD facilities. Cost-effective management of environmental data compels DoD facilities to establish robust database systems that not only address the complex and multifaceted environmental monitoring, record-keeping, and reporting requirements demanded by these rules but enable environmental management decision-makers to gauge improvements in environmental performance. The Enterprise Environmental Safety and Occupational Health Management Information System (EESOH-MIS) is a new electronic database developed by the U.S. Air Force to manage both the data needs associated with regulatory compliance programs across its facilities as well as the non-regulatory environmental information that supports installation business practices. The U.S. Air Force, which has adopted the Plan-Do-Check-Act methodology as the EMS standard that it will employ to address EO 13148 requirements.  相似文献   

11.
Actinomycetes are the dominant bacteria isolated from bioaerosols sampled at composting facilities. Here, a novel method for the isolation of actinomycetes is reported, overcoming masking of conventional agar plates, as well as reducing analysis time and costs. Repeatable and reliable actinomycetes growth was best achieved using a soil compost media at an incubation temperature of 44 °C and 7 days’ incubation. The results are of particular value to waste management operators and their advisors undertaking regulatory risk assessments that support environmental approvals for compost facilities.  相似文献   

12.
ABSTRACT

Owners of hazardous waste treatment, storage, and disposal facilities, and certain major air pollution sources, must conduct several separate ambient air dispersion modeling analyses before beginning construction of new facilities or modifying existing facilities. These analyses are critical components of the environmental permitting and facility certification processes and must be completed to the satisfaction of federal, state, and local regulatory authorities.

The U.S. Army has conducted air dispersion modeling for its proposed chemical agent disposal facilities to fulfill the following environmental regulatory and risk management requirements: (1) Resource Conservation and Recovery Act human health and ecological risk assessment analysis for the hazardous waste treatment and storage permit applications, (2) Quantitative Risk Assessment to support the site-specific risk management programs, and (3) Prevention of Significant Deterioration ambient air impact analysis for the air permit applications. The purpose of these air dispersion modeling studies is to show that the potential impacts on human health and the environment, due to operation of the chemical agent disposal facilities, are acceptable. This paper describes and compares the types of air dispersion models, modeling input data requirements, modeling algorithms, and approaches used to satisfy the three environmental regulatory and risk management requirements listed above. Although this paper discusses only one industry (i.e., chemical demilitarization), the information it contains could help those in other industries who need to communicate to the public the purpose and objectives of each modeling analysis. It may also be useful in integrating the results of each analysis into an overarching summary of compliance and potential risks.  相似文献   

13.

Purpose  

The two artificial sweeteners cyclamate (CYC) and acesulfame (ACE) have been detected in wastewater and drinking water treatment plants. As in both facilities ozonation might be applied, it is important to find out if undesired oxidation products (OPs) are formed.  相似文献   

14.
This is the consolidated report of emissions of PCDD/F from facilities in the organic chemical manufacturing chain leading to polyvinyl chloride. Data have been gathered from facilities in the US and Canada from a number of manufacturers and at various steps in the manufacturing process. Estimates of US emissions or transfers of PCDD/F were generated on an "Upper Bound" and "Most Likely" basis. The Most Likely estimate of US emissions of PCDD/F to the open environment, that is, air, water and land surface by facilities in this chain, based on evaluation of non-detects at one-half the detection limit is about 12 g I-TEQ per year. On this same basis, an estimated 19 g is disposed of in secure landfills.  相似文献   

15.
This study sought to fill the gap in information about the type and the concentration of bioaerosols present in the air of biomethanization facilities (BF). Evaluation of bioaerosol composition and concentration was achieved in two biomethanization facilities located in Eastern Canada, during summer and winter. In order to have a thorough understanding of the studied environment, the methodology combined culture of bacteria and molds, qualitiative polymerase chain reaction (qPCR) for specific microorganisms, endotoxin quantification, and next-generation sequencing (NGS) for bacterial diversity. Results revealed that workers in biomethanization facilities are exposed to bioaerosols and pathogenic microorganisms similar to those found in composting plants. However, human exposure levels to bioaerosols are lower in BF than in composting plants. Despite these differences, use of personal protective equipment is recommended to lower the risks of health problems.

Implications: Biomethanization is a new technology used in eastern Canada for waste management. In the next few years, it is expected that there will be an expansion of facilities in response of tight governmental regulations. Workers in biomethanization facilities are exposed to various amounts of bioaerosols composed of some harmful microorganisms. Therefore, monitoring this occupational exposure could be an interesting tool for improving worker’s health.  相似文献   


16.
Municipal solid waste (MSW) management is a major concern for highly urbanized societies. Among proposed MSW management systems, regionalization programs generally have received considerable attention. This study analyzes real-world operational data to assess different MSW management policies, especially regionalization strategies, and their impact on MSW management systems in the Taipei metropolitan area. Linear programming is also used to identify the minimum costs sustained by each policy. The linear programming results show that regionalization programs are more economical and also improve incinerator operation efficiency. Sensitivity analysis indicates that the minimum treatment requirement of incinerators is a very sensitive influence on the MSW flows distributed through the entire region. The MSW of several "sensitive" administrative districts will be allocated to different treatment facilities according to different management strategies. A list of preferential sequences of MSW treatment and disposal facilities can also be identified by the model presented in this study. The results of this study may provide a useful tool for aiding decision-making related to real-world MSW management problems.  相似文献   

17.
Mathematical models of radionuclide distribution and transport in the environment have been developed to assess the impact on people of routine and accidental releases of radioactivity from a variety of nuclear activities, including: weapons development, production, and testing; power production; and waste disposal. The models are used to estimate human exposures and doses in situations where measurements have not been made or would be impossible or impractical to make. Model results are used to assess whether nuclear facilities are operated in compliance with regulatory requirements, to determine the need for remediation of contaminated sites, to estimate the effects on human health of past releases, and to predict the potential effects of accidental releases or new facilities. This paper describes the various applications and types of models currently used to represent the distribution and transport of radionuclides in the terrestrial and aquatic environments, as well as integrated global models for selected radionuclides and special issues in the fields of solid radioactive waste disposal and dose reconstruction. Particular emphasis is placed on the issue of improving confidence in the model results, including the importance of uncertainty analysis and of model verification and validation.  相似文献   

18.
广州市城市生活垃圾管理系统规划   总被引:7,自引:0,他引:7  
运用最小费用规划模型,选取运输费用以及各处理设施(包括垃圾焚烧、制肥、回收利用、 填埋和中转处理)的处理费用为因子,同时把经济收入作为负的费用从中扣除,对选取的三个规划方案进行了计算,得出了广州市市区城市生活垃圾管理系统处理的最低费用,并给出了市属8个区的垃圾量相应的处理设置。  相似文献   

19.
In this study, in order to understand accurate calculation of greenhouse gas emissions of urban solid waste incineration facilities, which are major waste incineration facilities, and problems likely to occur at this time, emissions were calculated by classifying calculation methods into 3 types. For the comparison of calculation methods, the waste characteristics ratio, dry substance content by waste characteristics, carbon content in dry substance, and 12C content were analyzed; and in particular, CO2 concentration in incineration gases and 12C content were analyzed together. In this study, 3 types of calculation methods were made through the assay value, and by using each calculation method, emissions of urban solid waste incineration facilities were calculated then compared. As a result of comparison, with Calculation Method A, which used the default value as presented in the IPCC guidelines, greenhouse gas emissions were calculated for the urban solid waste incineration facilities A and B at 244.43 ton CO2/day and 322.09 ton CO2/day, respectively. Hence, it showed a lot of difference from Calculation Methods B and C, which used the assay value of this study. It is determined that this was because the default value as presented in IPCC, as the world average value, could not reflect the characteristics of urban solid waste incineration facilities. Calculation Method B indicated 163.31 ton CO2/day and 230.34 ton CO2/day respectively for the urban solid waste incineration facilities A and B; also, Calculation Method C indicated 151.79 ton CO2/day and 218.99 ton CO2/day, respectively.

Implications: This study intends to compare greenhouse gas emissions calculated using 12C content default value provided by the IPCC (Intergovernmental Panel on Climate Change) with greenhouse gas emissions calculated using 12C content and waste assay value that can reflect the characteristics of the target urban solid waste incineration facilities. Also, the concentration and 12C content were calculated by directly collecting incineration gases of the target urban solid waste incineration facilities, and greenhouse gas emissions of the target urban solid waste incineration facilities through this survey were compared with greenhouse gas emissions, which used the previously calculated assay value of solid waste.  相似文献   


20.
Abstract

Chenfang Lin is with the Department of Soil and Environmental Science at National Chung Hsing University.Municipal solid waste (MSW) management is a major concern for highly urbanized societies. Among proposed MSW management systems, regionalization programs generally have received considerable attention. This study analyzes real-world operational data to assess different MSW management policies, especially regionalization strategies, and their impact on MSW management systems in the Taipei metropolitan area. Linear programming is also used to identify the minimum costs sustained by each policy. The linear programming results show that regionalization programs are more economical and also improve incinerator operation efficiency. Sensitivity analysis indicates that the minimum treatment requirement of incinerators is a very sensitive influence on the MSW flows distributed through the entire region. The MSW of several “sensitive” administrative districts will be allocated to different treatment facilities according to different management strategies. A list of preferential sequences of MSW treatment and disposal facilities can also be identified by the model presented in this study. The results of this study may provide a useful tool for aiding decision-making related to real-world MSW management problems.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号