首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 625 毫秒
1.
A simple system to evaluate the 222Rn (radon) exhalation rate from soil has been improved. A sampling cuvette of 2.1 L is placed so that it covers the targeted ground soil, and radon emanating from the soil accumulates within the cuvette for 24 h. Its internal radon concentration is measured by the combination of an activated charcoal (PICO-RAD) and a liquid scintillation counting system. This study shows variations of the conversion factor (CF: unit Bq m(-3)/cpm) of PICO-RAD. The range of CF due to temperature (10-30 degrees C) was between -21% and +69%, and this due to humidity (30-90%) was between 0% and -15%. Humidity and radon concentration in the cuvette covering soil tended to saturate in a few hours. The above information was used to correct the CF for the evaluation. The improved system shows high reliability and can be easily applied to natural environments.  相似文献   

2.
Galicia (NW Spain) is a radon-prone area in the Iberian Peninsula. Measurements were carried out at a rural dwelling, with an annual average of radon concentration over 4000 Bq m−3 and a maximum of 9000 Bq m−3, found during a radon screening campaign held in the Autonomous Community of Galicia. We performed a detailed study to identify the main contamination source and the behaviour of the radon concentration, in which a linear dependence with temperature was verified, once corrected for relative humidity. We used different passive methods (charcoal canisters and two types of etched track detectors) as well as a radon concentration monitor that provided continuous measurement. Subsequent to this characterization, and in order to reduce the high radon concentration, a remedial action was developed using different passive and forced ventilation methods. A modified subslab depressurization technique was found to be the most effective remedy, providing a radon concentration reduction of around 96%. This method also has the advantages of being inexpensive and reliable over time.  相似文献   

3.
Radon adsorption by activated charcoal collectors such as PicoRad radon detectors is known to be largely affected by temperature and relative humidity. Quantitative models are, however, still needed for accurate radon estimation in a variable environment. Here we introduce a temperature calibration formula based on the gas adsorption theory to evaluate the radon concentration in air from the average temperature, collection time, and liquid scintillation count rate. On the basis of calibration experiments done by using the 25 m3 radon chamber available at the National Institute of Radiological Sciences in Japan, we found that the radon adsorption efficiency may vary up to a factor of two for temperatures typical of indoor conditions. We expect our results to be useful for establishing standardized protocols for optimized radon assessment in dwellings and workplaces.  相似文献   

4.
In order to maintain an acceptable Indoor Air Quality (IAQ), policies, strategies and guidelines have been developed worldwide and exposure concentrations of the indoor radon have been specified. Mapping indoor radon levels for a region could be done with intensive measurements on a large number of samples. To obtain the most accurate estimate of the levels with the uncertainties specified, a statistical model has been developed in this study to predict the fractions of samples in a region having an average radon level above the action levels of 150Bqm(-3) and 200Bqm(-3). The model was based on a transformation of the variation from a small sample set of data to a population geometric distribution via an estimator, known as the 'sample correction factor'. Using a dataset from a cross-sectional measurement of indoor radon levels in 216 Hong Kong offices, where the mean was 37.2Bqm(-3) and the 68% range was from 17.3Bqm(-3) to 80.3Bqm(-3), the 'sample correction factor' was evaluated and tested by the Monte-Carlo simulations. The model estimates of the fractions above the indoor radon action levels 150Bqm(-3) and 200Bqm(-3) (1.2-7.7% and 0.4-4.1% for a sample size of 20, 2.8-5.1% and 0.8-2.4% for a sample size of 60) were demonstrated to be consistent with those determined from the dataset (3.5% and 1.4%). With the 'sample correction factor' thus quantified, it will be possible to provide the required data for the policymakers making appropriate decisions on resources and manpower management.  相似文献   

5.
Significantly elevated radon concentrations were found in several adjacent houses in Clinton, New Jersey. The United States Environmental Protection Agency screened 56 of the houses and selected 10 for demonstration of radon-reduction techniques. Each of the 10 houses received an intensive radon diagnostic evaluation before a house-specific radon reduction plan was developed. Depressurization effects caused by temperature differentials and the operation of mechanical equipment were quantified. Before and after radon reduction plans were implemented, radon concentrations were determined by charcoal canisters and continuous radon monitors. A variety of sealing and subslab depressurization techniques were applied to the 10 houses. Radon concentrations were reduced by over 95% in all 10 houses. The cost of applying radon reduction techniques ranged from $1500 to $8500 per house. House construction characteristics were described which contributed to the high cost of radon reduction. In summary, the 10-house radon reduction demonstration in Clinton, New Jersey was successful in showing homeowners with similar house types some effective ways of reducing radon concentrations.  相似文献   

6.
To quantify the effectiveness of Sub-Slab Depressurisation, widely used in the United Kingdom (U.K.) to mitigate indoor radon gas levels in residential properties, a study was made of radon concentration data collected from a set of 170 homes situated in Radon Affected Areas in Northamptonshire and neighbouring counties, remediated using conventional sump/pump technology. A high incidence of satisfactory remediation outcomes was achieved, with 100% of the houses remediated demonstrating post-remediation radon concentrations below the U.K. domestic Action Level of 200 Bq m(-3), while more than 75% of the sample exhibited radon mitigation factors (defined as the ratio of radon concentrations following and prior to remediation) <0.2. Two systematic trends are identified. Firstly, absolute radon concentration reduction following remediation is directly proportional to initial radon concentration, with a mean reduction factor of 0.96 and a residual component of around 75 Bq m(-3). Secondly, houses with lower initial radon concentrations demonstrate poorer (higher) mitigation factors. These observations support a model in which the total indoor radon concentration within a dwelling can be represented by two principal components, one susceptible to mitigation by sub-slab depressurisation, the other remaining essentially unaffected. The first component can be identified with radon emanating from the subsoil and bedrock geologies, percolating through the foundations of the dwelling as a component of the soil-gas, and potentially capable of being attenuated by sub-slab depressurisation or radon-barrier remediation technologies. The second contribution can be identified with radon emanating from materials used in the construction of the dwelling with a further contribution from the natural background level, and is essentially unaffected by ground-level remediation strategies. Modelling of a multi-component radon dependency using ground-radon attenuation factors derived from the experimental data, in conjunction with typical background and structural-radon levels, yields behaviour in good agreement with the observed dependence of mitigation factor on initial radon concentration.  相似文献   

7.
Galician soils are among those with the highest (222)Rn exhalation rates in Spain. A year-round study of the indoor (222)Rn concentration in buildings in the Santiago de Compostela area (Galicia, Northwest of Spain) was performed. The study is based on systematic samplings with active charcoal canisters, following a modified EPA 520/5-87-005 protocol. These measurements were complemented by others obtained using etched track dosimeters. Each data set follows a log-normal distribution, with a geometric mean of (253+/-3)Bqm(-3) for charcoal canisters and (285+/-2.5)Bqm(-3) for etched track detectors. After correcting for the different measuring conditions, the mean value of both methods differed by only 2%. A careful analysis of the seasonal dependence of our measurements did not reveal any significant seasonal variations in the (222)Rn concentration. Parallel to these measurements, different meteorological parameters were recorded, which revealed a direct correlation between the indoor radon concentration and the outdoor temperature derivative with respect to time.  相似文献   

8.
To identify the most applicable technology for the short-term assessment of domestic radon levels, comparative assessments of a number of integrating detector types, including track-etch, electret and activated charcoal were undertaken. Thirty-four unremediated dwellings in a high-radon area were monitored using track-etch detectors exposed for one-month and three-month periods. In parallel, one-week measurements were made in the same homes at one-month intervals, using co-located track-etch, charcoal and electret detectors exposed simultaneously, while three of the homes were also monitored by continuous-sampling detectors at hourly intervals over extended periods. Calibration of dose-integrating devices against each other and against continuous-monitoring systems confirmed good responsivity and linearity. Although track-etch, charcoal and electret devices are suitable in principle for one-week measurements, zero-exposure offset and natural radon variability cause many one-week results to be equivocal, necessitating repetition of the measurement. One-week exposures can be reliable indicators in low-radon areas or for new properties, but in high-radon areas, the use of three-month exposures is indicated. This analysis also established confidence limits for short-term measurements.  相似文献   

9.
The paper presents the results of indoor radon concentration survey in 201 homes and offices in Niska Banja (the Spa of Nis), a well-known health resort and a spa in the South-East of Serbia. Radon indoor concentrations were determined by active charcoal method, according to standard EPA procedure. The indoor radon concentrations were in the range of up to 200 Bq/m(3) (47%), from 200-600 Bq/m(3) (26%) and over 600 Bq/m(3) (27%). Three areas of extremely high average radon concentrations were found (1,340-4,340 Bq/m(3)), with a maximum above 13,000 Bq/m(3). The content of natural radionuclides ((226)Ra, (214)Pb, (214)Bi, (235)U, (228)Ac, (212)Pb, (212)Bi, (208)Tl, (40)K) and (137)Cs, as well as the content of total uranium, thorium and potassium in mud used in peloidotherapy in the Health Institute "Niska Banja" was determined, too. The activities of the radionuclides were determined on an HPGe detector, by standard gamma spectroscopy. The results indicated considerably high amounts of total uranium and thorium (0.021 g/kg mud and 0.003 g/kg mud, respectively), due to the karsts origin of the soil.  相似文献   

10.
Radon-222 in Brazil: an outline of indoor and outdoor measurements   总被引:3,自引:0,他引:3  
This study discusses the methodology for measuring and assessing the radon concentration in indoor and outdoor environments. A research study was developed to investigate the long-term behavior of the diurnal and seasonal fluctuations of radon (222)Rn EEC (Equilibrium-Equivalent Concentration) and the influence of temperature and other climatic aspects on this behavior. The study was performed by means of both integrated and instantaneous measurements of radon and its short-lived daughter products for a period of 1 year in an indoor environment in Rio de Janeiro city, Brazil (reference environment), with continuous measurement, using a radon monitor with an alpha spectrometry detector.For a single day, a variability of about 50% could be observed in the (222)Rn EEC values measured on a hourly basis, with a maximum occurring early in the morning and a minimum in the afternoon. For the long-term period, seasonality is responsible for a two order of magnitude variability, with a maximum of 50 Bq.m(-3) in winter (dry season) and a minimum of 0.5 Bq.m(-3) in the summer months (wet season), outdoors. A negative correlation with temperature was observed. The conclusions of this experiment led to a survey of radon gas concentration in dwellings in Rio de Janeiro city, Brazil, in urban area with nearly 7 million inhabitants, through integrated sampling methods, using a Solid State Nuclear Track Detectors Technique (SSNTD). The study was conducted in different geomorphological locations in town. The radon gas concentration in Rio de Janeiro dwellings ranged from 5 Bq.m(-3) to 200 Bq.m(-3). A good correlation between indoor radon gas concentration and location of dwellings was observed. The seashore areas presented the lowest levels of indoor radon concentration, whereas the highest levels were found close to the mountains.  相似文献   

11.
A large scale radon survey using track etch detectors has been carried out from 1995 to 1998 in Greece in order to estimate the radon concentrations in Greek dwellings and the exposure of the Greek population to radon. The total data set consisted of 1,277 samples. Residential potential alpha energy concentration values ranged between (0.024 +/- 0.009) and (8 +/- 1) WLM per year (P < 0.05) and effective doses between (0.09 +/- 0.04) and (28 +/- 4) mSv (P < 0.05). The mean lifetime risk for the Greek population due to radon was found to be 0.4%.  相似文献   

12.
Evaluation was made of the distribution of radon gas and radiation exposure rates in the four main natural gas treatment facilities in Syria. The results showed that radiation exposure rates at contact of all equipment were within the natural levels (0.09-0.1 microSvh(-1)) except for the reflex pumps where a dose rate value of 3 microSvh(-1) was recorded. Radon concentrations in Syrian natural gas varied between 15.4 Bq m(-3) and 1141 Bq m(-3); natural gas associated with oil production was found to contain higher concentrations than the non-associated natural gas. In addition, radon concentrations were higher in the central processing facilities than the wellheads; these high levels are due to pressurizing and concentrating processes that enhance radon gas and its decay products. Moreover, the lowest 222Rn concentration was in the natural gas fraction used for producing sulfur; a value of 80 Bq m(-3) was observed. On the other hand, maximum radon gas and its decay product concentrations in workplace air environments were found to be relatively high in the gas analysis laboratories; a value of 458 Bq m(-3) was observed. However, all reported levels in the workplaces in the four main stations were below the action level set by IAEA for chronic exposure situations involving radon, which is 1000 Bq m(-3).  相似文献   

13.
The concentration activity of radon-222 has been monitored, with some interruptions, from 1997 to 2005 in the end section of a slightly rising, dead-end, 38-m long tunnel located in the Phulchoki hill, near Kathmandu, Nepal. While a high concentration varying from 6 x 10(3) Bq m(-3) to 10 x 10(3) Bq m(-3) is observed from May to September (rainy summer season), the concentration remains at a low level of about 200 Bq m(-3) from October to March (dry winter season). This reduction of radon concentration is associated with natural ventilation of the tunnel, which, contrary to expectations for a rising tunnel, takes place mainly from October to March when the outside air temperature drops below the average tunnel temperature. This interpretation is supported by temperature measurements in the atmosphere of the tunnel, a few meters away from the entrance. The temporal variations of the diurnal amplitude of this temperature indeed follow the ventilation rate deduced from the radon measurements. In the absence of significant ventilation (summer season), the radon exhalation flux at the rock surface into the tunnel atmosphere can be inferred; it exhibits a yearly variation with additional transient reductions associated with heavy rainfall, likely to be due to water infiltration. No effect of atmospheric pressure variations on the radon concentration is observed in this tunnel. This experiment illustrates how small differences in the location and geometry of a tunnel can lead to vastly different behaviours of the radon concentration versus time. This observation has consequences for the estimation of the dose rate and the practicability of radon monitoring for tectonic purposes in underground environments.  相似文献   

14.
High-resolution gamma spectrometry was used to determine the concentration of 40K, 238U and 232Th series in soil samples taken from areas surrounding the city of Aldama, in Chihuahua. Results of indoor air short-time sampling, with diffusion barrier charcoal detectors, revealed relatively high indoor radon levels, ranging from 29 to 422 Bq/m3; the radon concentrations detected exceeded 148 Bq/m3 in 76% of the homes tested. Additionally, liquid scintillation counting showed concentrations of radon in drinking water ranging from 4.3 to 42 kBq/m3. The high activity of 238U in soil found in some places may be a result of the uranium milling process performed 20 years ago in the area. High radon concentrations indoor and in water may be explained by assuming the presence of uranium-bearing rocks underneath of the city, similar to a felsic dike located near Aldama. The estimated annual effective dose of gamma radiation from the soil and radon inhalation was 3.83 mSv.  相似文献   

15.
Fifty granitic rock samples were collected from different plutons in the central part of the Eastern Desert of Egypt and were analyzed for specific concentrations of (238)U, (232)Th and (40)K radionuclei. The measurements were carried out using a high performance and stability Nomad Plus spectroscopy system attached to a 1.7 keV (FWHM) HPGe detector. The spectra were analyzed using the direct gamma counting comparison method as well as the traditional absolute efficiency curve method. The highest average value of (238)U concentration (1184 Bq kg(-1)) was observed at EI Misikat region whereas the highest average values of (40)K and (232)Th concentration (2301.8 and 162.5 Bq kg(-1) respectively), were detected at Gabal Homret Waggat area. The radium equivalent activity (Ra(eq)), the absorbed dose rate (D), the external hazard index (H(ex)) and the annual gonadal dose equivalent were also calculated and compared to the international recommended values. Radon exhalation rate from the rock samples were measured using the activated charcoal canister method. The average value of radon exhalation varies from 0.052 to 0.69 Bq m(-2) h(-1) and depends on the specific concentration of uranium.  相似文献   

16.
Concentrations of airborne radon ranging from 0.05 to 135 pCi/L were found in houses in Maine. Tracketch cups were placed in five positions for 100 houses to determine integrated average radon concentrations over the period October 1980–May 1981. To investigate the association between elevated radon concentrations in well water and the indoor airborne radon concentrations, the radon in the water supplies of these houses was measured by liquid scintillation. Monitors of airborne radon, recording in intervals of 10 min for periods of 5–7 days, were used for dynamic studies in 18 houses, determining the component of airborne radon associated with major water uses, such as showers, laundry, and dishwashing, which liberate radon in bursts. House residents kept logs noting the time of major water uses. For some of the houses, ventilation rates ranging from 0.3 to 2 air changes per hour were determined by analysis of the dynamic data. The component of airborne radon associated with water sources was found to vary inversely with ventilation rate and directly with waterborne radon concentration, with 0.8 ± 0.2 pCi Rn/L air per nCi Rn/L water at a ventilation rate of 1.0 air change per hour. The data are pertinent to a study which has revealed significant correlations between county averages, from the National Cancer Institute, or age-adjusted cancer mortality rates in Maine and average values of radon concentrations in water for the counties.  相似文献   

17.
To predict the radon concentration in a house environment and to understand the role of all factors affecting its behavior, it is necessary to recognize time variation in both air exchange rate and radon entry rate into a house. This paper describes a new approach to the separation of their effects, which effectively allows continuous estimation of both radon entry rate and air exchange rate from simultaneous tracer gas (carbon monoxide) and radon gas measurement data. It is based on a state-space statistical model which permits quick and efficient calculations. Underlying computations are based on (extended) Kalman filtering, whose practical software implementation is easy. Key property is the model's flexibility, so that it can be easily adjusted to handle various artificial regimens of both radon gas and CO gas level manipulation. After introducing the statistical model formally, its performance will be demonstrated on real data from measurements conducted in our experimental, naturally ventilated and unoccupied room. To verify our method, radon entry rate calculated via proposed statistical model was compared with its known reference value. The results from several days of measurement indicated fairly good agreement (up to 5% between reference value radon entry rate and its value calculated continuously via proposed method, in average). Measured radon concentration moved around the level approximately 600 Bq m(-3), whereas the range of air exchange rate was 0.3-0.8 (h(-1)).  相似文献   

18.
A new winter and summer investigation of radon concentrations in parts of the Ogof Ffynnon Ddu system at Penwyllt, South Wales, has been carried out using 100 environmental National Radiological Protection Board track etch detectors. Fifty detectors were installed in the system in December 1998 and again in August 1999 for a period of a month. The data obtained confirm that the system has moderately high radon concentrations with a system mean of 2318 Bq m(-3) in winter and 2844 Bq m(-3) in summer. Traverse means have a summer high of 3094 Bq m(-3) for OFDI to Cwm Dwr and a winter low of 1946 Bq m(-3). The extremely high concentrations approaching 20,000 Bq m(-3), reported previously from the system (Hyland, 1995), have not been reproduced. The data show that the airflow directions at the entrances are not what might have been predicted. Air appears to be largely continuously emerging from the lowest entrance but, at the higher entrances, conversely to the predictions, in winter air enters and in summer appears to be coming out or is variable. Internally, there are sites that in winter have very low radon concentrations that can only be explained by the ingress of fresh air. These are not matched in the summer experiment, again indicating that ingress of fresh air to some parts of the system is very variable. The data illustrate the complexity of airflow within a multi-entrance system but behind these variations several mean concentrations can be obtained from which an approximation of the dose likely to be received can be calculated. Using the maximum mean concentration obtained, 3094 Bq m(-3), and using the latest dose conversion, a 10 h underground trip in the Ogof Ffynnon Ddu system yields a calculated dose of 0.12 mSv. Given that the recommended limit for a member of the public is 1 mSv, this dose would be reached after about 80 h of caving in the system.  相似文献   

19.
Although United Kingdom (UK) Building Regulations applicable to houses constructed since 1992 in Radon Affected Areas address the health issues arising from the presence of radon in domestic properties and specify the installation of radon-mitigation measures during construction, no legislative requirement currently exists for monitoring the effectiveness of such remediation once construction is completed and the houses are occupied. To assess the relative effectiveness of During-Construction radon reduction and Post-Construction remediation, radon concentration data from houses constructed before and after 1992 in Northamptonshire, UK, a designated Radon Affected Area, was analysed. Post-Construction remediation of 73 pre-1992 houses using conventional fan-assisted sump technology proved to be extremely effective, with radon concentrations reduced to the Action Level, or below, in all cases. Of 64 houses constructed since 1992 in a well-defined geographical area, and known to have had radon-barrier membranes installed during construction, 11% exhibited radon concentrations in excess of the Action Level. This compares with the estimated average for all houses in the same area of 17%, suggesting that, in some 60% of the houses surveyed, installation of a membrane has not resulted in reduction of mean annual radon concentrations to below the Action Level. Detailed comparison of the two data sets reveals marked differences in the degree of mitigation achieved by remediation. There is therefore an ongoing need for research to resolve definitively the issue of radon mitigation and to define truly effective anti-radon measures, readily installed in domestic properties at the time of construction. It is therefore recommended that mandatory testing be introduced for all new houses in Radon Affected Areas.  相似文献   

20.
Domestic radon levels in parts of the United Kingdom are sufficiently high as to increase the risk of lung-cancer among residents. Public health campaigns in the county of Northamptonshire, a designated radon Affected Area with 6.3% of homes having average radon levels in excess of the UK Action Level of 200 Bq m(-3), have encouraged householders to test for radon and then, if indicated to be necessary, to carry out remediation in their homes. These campaigns have been only partially successful, since to date only 40% of Northamptonshire houses have been tested, and only 15% of those householders finding raised levels have proceeded to remediate. Those who remediate have been shown to have smaller families, to be older, and to include fewer smokers than the average population, suggesting that current strategies to reduce domestic radon exposure are not reaching those most at risk. During 2004-2005, the NHS Stop-Smoking Services in Northamptonshire assisted 2847 smokers to quit to the 4-week stage, the 15% (435) of these 4-week quitters remaining quitters at 1year forming the subjects of a retrospective study considering whether smoking cessation campaigns contribute significantly to radon risk reduction. Quantitative assessment of the risk of lung-cancer among the study population, from knowledge of the individuals' age, gender, and smoking habits, together with the radon levels in their homes, demonstrates that smoking cessation programmes have significant added value in reducing the incidence of lung-cancer in radon Affected Areas, and contribute a substantially greater health benefit at a lower cost than the alternative strategy of reducing radon levels in the smokers' homes, while they remain smokers. Both radon remediation and smoking cessation programmes are very cost effective in Northamptonshire, with smoking cessation being significantly more cost effective, and these are potentially valuable programmes to drive health improvements through promotion of the uptake or environmental management for radon in the home.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号