首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 982 毫秒
1.
Different methods exist for measuring soil water and solute fluxes in and below the root zone and have been critically reviewed. Besides indirect methods (e.g. water balance, tensiometer, time domain reflectometry – TDR, frequency domain reflectometry – FDR, environmental tracer) direct methods (e.g. drainage-type lysimeter, water fluxmeter) have a long tradition and have been successfully used in seepage research. A large weighable out door lysimeter is the best method for obtaining reliable data about seepage water quantity and quality, but it involves significant investment and additional expenses for maintenance. To tackle this problem new methods for the vertical collection of large volume soil monoliths (up to 6 m3) as well as for the horizontal collection (up to 6 m3) have been developed. For the placement of the lysimeter a container lysimeter unit was constructed, which is cheaper than a conventional steel or concrete cellar. Furthermore, the technical design of the newly developed lysimeter types as a weighable gravitation lysimeter, a weighable groundwater lysimeter and a lateral flow lysimeter are presented.  相似文献   

2.
Landfill aeration by means of low pressure air injection is a promising tool to reduce long term emissions from organic waste fractions through accelerated biological stabilization. Top covers that enhance methane oxidation could provide a simple and economic way to mitigate residual greenhouse gas emissions from in situ aerated landfills, and may replace off-gas extraction and treatment, particularly at smaller and older sites. In this respect the installation of a landfill cover system adjusted to the forced-aerated landfill body is of great significance. Investigations into large scale lysimeters (2 × 2 × 3 m) under field conditions have been carried out using different top covers including compost materials and natural soils as a surrogate to gas extraction during active low pressure aeration. In the present study, the emission behaviour as well as the water balance performance of the lysimeters has been investigated, both prior to and during the first months of in situ aeration. Results reveal that mature sewage sludge compost (SSC) placed in one lysimeter exhibits in principle optimal ambient conditions for methanotrophic bacteria to enhance methane oxidation. Under laboratory conditions the mature compost mitigated CH4 loadings up to 300 l CH4/m2 d. In addition, the compost material provided high air permeability even at 100% water holding capacity (WHC). In contrast, the more cohesive, mineral soil cover was expected to cause a notably uniform distribution of the injected air within the waste layer. Laboratory results also revealed sufficient air permeability of the soil materials (TS-F and SS-Z) placed in lysimeter C. However, at higher compaction density SS-Z became impermeable at 100% WHC.Methane emissions from the reference lysimeter with the smaller substrate cover (12–52 g CH4/m2 d) were significantly higher than fluxes from the other lysimeters (0–19 g CH4/m2 d) during in situ aeration. Regarding water balance, lysimeters covered with compost and compost-sand mixture, showed the lowest leachate rate (18–26% of the precipitation) due to the high water holding capacity and more favourable plant growth conditions compared to the lysimeters with mineral, more cohesive, soil covers (27–45% of the precipitation).On the basis of these results, the authors suggest a layered top cover system using both compost material as well as mineral soil in order to support active low-pressure aeration. Conventional soil materials with lower permeability may be used on top of the landfill body for a more uniform aeration of the waste due to an increased resistance to vertical gas flow. A compost cover may be built on top of the soil cover underlain by a gas distribution layer to improve methane oxidation rates and minimise water infiltration. By planting vegetation with a high transpiration rate, the leachate amount emanating from the landfill could be further minimised. The suggested design may be particularly suitable in combination with intermittent in situ aeration, in the later stage of an aeration measure, or at very small sites and shallow deposits. The top cover system could further regulate water infiltration into the landfill and mitigate residual CH4 emissions, even beyond the time of active aeration.  相似文献   

3.
Performance of compacted clay liners commonly used as landfill barrier systems can be subject to decline in terms of hydraulic conductivity if left exposed to atmospheric conditions for an extended period of time prior to placement of overlaying layers. The resulting desiccation cracking can lead to increased hydraulic conductivity. Desiccation crack intensity was studied for three clayey soils commonly used for construction of landfill barrier system in a relatively large scale test setup exposed to real time atmospheric conditions over a complete annual cycle. A white separator geotextile cover was presumed to be capable of reducing the intensity of desiccation cracking through absorbing and maintaining higher amounts of moisture and reducing the temperature of the soil surface in comparison to a directly exposed soil surface. Desiccation cracking was monitored using a digital imaging technique for three compacted clay liners in two sets, one open to air and the second covered with the white geotextile. Crack intensity factor approached a relatively stable phase after certain cycles corresponding to atmospheric dry wet cycles. The results indicated that the white separator geotextile was capable of reducing the crack intensity factor by 37.4–45.9% throughout the experiment including the cyclic phase of desiccation cracking. During the stable phase, the maximum reduction in crack intensity factor of 90.4% as a result of applying geotextile cover was observed for the soil with the lowest plastic index and clay content and therefore the lowest magnitude of crack intensity factor. The other two soils with similar clay content but different plastic index showed 23.6% and 52.2% reductions in crack intensity factor after cyclic phase when covered with geotextile.  相似文献   

4.
Leachate recirculation has been shown in lysimeter, pilot-scale and full-scale investigations to reduce the time required for waste stabilization, improve leachate quality, provide the opportunity for leachate volume reduction, and to enhance the rate of gas production. New generation full-scale landfills are implementing recirculation as a leachate management tool with increasing frequency. Leachate recirculation techniques used at full-scale landfills include pre-wetting of waste, leachate spraying, surface ponds, vertical injection wells and horizontal introduction systems. From observations of operating full-scale recirculating landfills, it appears to be important to provide flexibility in design, minimize low permeability daily and intermediate cover, include adequateex situstorage volume, control infiltration into the landfill, and utilize waste moisture holding capacity efficiently.  相似文献   

5.
Conventional landfill cover systems for municipal solid waste include low-permeability compacted clay barriers to minimize infiltration into the landfilled waste. Such layers are vulnerable in climates where arid to semi-arid conditions prevail, whereby the clay cover tends to desiccate and crack, resulting in drastically higher infiltration, i.e., lower cover efficiency. To date, this phenomenon, which has been reported in field observations, has not been adequately assessed. In this paper, the performance of a cover system solely relying on a clay barrier was simulated using a numerical finite element formulation to capture changes in the clay layer and the corresponding modified hydraulic characteristics. The cover system was guided by USEPA Subtitle-D minimum requirements and consisted of a clay layer underlying a protective vegetated soil. The intrinsic characteristics of the clay barrier and vegetative soil cover, including their saturated hydraulic conductivities and their soil-water characteristic curves, were varied as warranted to simulate intact or "cracked" conditions as determined through the numerical analyses within the proposed methodology. The results indicate that the levels of percolation through the compromised or cracked cover were up to two times greater than those obtained for intact covers, starting with an intact clay hydraulic conductivity of 10(-5)cm/s.  相似文献   

6.
Incinerator bottom ash (IBA) is a residual produced from incinerating municipal solid waste. In the past, IBA presented a big waste disposal problem; however, various recycling approaches have been adopted in recent years to mitigate this problem, as well as to provide a useful alternative to using primary aggregate resources. The use of IBA as an alternative to conventional aggregates in different civil engineering construction applications helps to conserve premium grade aggregate supplies; however, when IBA is in contact with water in the field, as a consequence of precipitation events or changes in water table, elements, such as salts and heavy metals, may be released to the soil and ground water. In this work, IBA waste was mixed with limestone aggregate to produce a blend with acceptable mechanical properties and minimum environmental risks for use as road foundation. The study focused on evaluating potential environmental impacts of some constituents, including sulphate, chloride, sodium, copper, zinc and lead in IBA blends using a lysimeter as a large scale leaching tool. Moreover, a specific scenario simulating field conditions was adopted in the lysimeter to assess the potential impact of changing conditions, such as IBA content in the blend, liquid to solid ratio (L/S) and pH value, on long-term release of heavy metals and salts. Then, numerical modelling was used to predict the release of the aforementioned constituents from IBA based on initial measurement of intrinsic material properties and the kinetic desorption process concept. Experimental results showed that zinc and lead were released in very low concentrations but sodium and sulphate were in high concentrations. The control limestone only blend also demonstrated low release concentrations of constituents in comparison to IBA blends, where constituent concentrations increased with increase in IBA content. Experimental results were compared with numerical results obtained using a non-equilibrium desorption model. Good agreement was found between the two sets of data.  相似文献   

7.
Methane is an important greenhouse gas emitted from landfill sites and old waste dumps. Biological methane oxidation in landfill covers can help to reduce methane emissions. To determine the influence of different plant covers on this oxidation in a compost layer, we conducted a lysimeter study. We compared the effect of four different plant covers (grass, alfalfa + grass, miscanthus and black poplar) and of bare soil on the concentration of methane, carbon dioxide and oxygen in lysimeters filled with compost. Plants were essential for a sustainable reduction in methane concentrations, whereas in bare soil, methane oxidation declined already after 6 weeks. Enhanced microbial activity - expected in lysimeters with plants that were exposed to landfill gas - was supported by the increased temperature of the gas in the substrate and the higher methane oxidation potential. At the end of the first experimental year and from mid-April of the second experimental year, the methane concentration was most strongly reduced in the lysimeters containing alfalfa + grass, followed by poplar, miscanthus and grass. The observed differences probably reflect the different root morphology of the investigated plants, which influences oxygen transport to deeper compost layers and regulates the water content.  相似文献   

8.
An alternative landfill capping technique known as ‘Phytocapping’ (establishment of perennial plants on a layer of soil placed over the waste) was trailed in Rockhampton, Australia. In this technique, trees were used as ‘bio-pumps’ and ‘rainfall interceptors’ and soil cover as ‘storage’ of water. The environmental performance of the phytocapping system was measured based on its ability to minimise water percolation into the waste. The percolation rate was modelled using HYDRUS 1D for two different scenarios (with and without vegetation) for the thick and thin caps, respectively. Results from the modelling showed percolation rates of 16.7 mm year?1 in thick cover and 23.8 mm year?1 in thin cover, both of which are markedly lower than those expected from a clay cap. Results from monitoring and observations showed that 19 trees out of 21 tree species grew well in the harsh landfill environment. Top ten performing species have been identified and are recommended to be grown on phytocaps in the Central Queensland region.  相似文献   

9.
A lysimeter study was performed to monitor effects of elevated ozone on juvenile trees of Fagus sylvatica L. as well as on the plant–soil system. During a fumigation period over almost three growing seasons, parameters related to plant growth, phenological development and physiology as well as soil functions were studied. The data analyses identified elevated ozone to delay leaf phenology at early and to accelerate it at late developmental stages, to reduce growth, some leaf nutrients (Ca, K) as well as some soluble phenolics (hydroxycinnamic acid derivatives, total flavonol glycosides). No or very weak ozone effects were found in mobile carbon pools of leaves (starch, sucrose), and other phenolic compounds (flavans). Altered gene expression related to stress and carbon cycling corresponded well with findings from leaf phenology and chemical composition analyses indicating earlier senescence and oxidative stress in leaves under elevated ozone. Conversely in the soil system, no effects of ozone were detected on soil enzyme activities, rates of litter degradation and lysimeter water balances. Despite the fact that the three reported years 2003–2005 were climatically very contrasting including a hot and dry as well as an extremely wet summer, and also mild as well as cold winters, the influence of ozone on a number of plant parameters is remarkably consistent, further underlining the phytotoxic potential of elevated tropospheric ozone levels.  相似文献   

10.
Methane oxidation in a landfill cover with capillary barrier   总被引:6,自引:0,他引:6  
The methane oxidation potential of a landfill cover with capillary barrier was investigated in an experimental plant (4.8 m x 0.8 m x 2.1m). The cover soil consisted of two layers, a mixture of compost plus sand (0.3 m) over a layer of loamy sand (0.9 m). Four different climatic conditions (summer, winter, spring and fall) were simulated. In and outgoing fluxes were measured. Gas composition, temperature, humidity, matrix potential and gas pressure were monitored in two profiles. CH4 oxidation rate within the investigated top cover ranged from 98% to 57%. The minimum was observed for a short time after irrigation. Temperature distribution, gas concentration profiles and lab-scaled batch experiments indicate that before irrigation the highest oxidising activity took place in a depth of about 30 cm. After irrigation the oxidising horizon seemed to migrate upwards since methanotrophic bacteria develop better there due to an adequate supply with oxygen. It can be assumed that the absence of oxygen is one of the most important limiting factors for the CH4 oxidation process. Abrupt cross-overs between horizons of different soil material may lead to zones of increased water saturation and decreased soil respiration.  相似文献   

11.
Hydraulic properties of waste and cover soil from Kimpo Metropolitan Landfill were experimentally measured by laboratory tests. The degree of compaction was changed to identify the effect on hydraulic conductivity, field capacity, and permanent wilting point. Properties were utilized in developing a reliable numerical tool for leachate analysis. HELP, a simulation model for hydrologic evaluation of landfill performance, was adopted for that purpose. For calibration, results from simulation using the parameter values measured by laboratory tests were compared against the field data. The model was applied to predict the leachate level change according to the degree of compaction and cover soil thickness variation. It was found that the increase in the degree of compaction for intermediate cover soil and waste results in the decrease of field capacity and hydraulic conductivity, hence, the increase of leachate level. The effect of cover layer thickness on the leachate level was minor. Based on the findings from laboratory and numerical experiments, a guideline for reclamation practice was recommended.  相似文献   

12.
13.
To reliably predict field operation performance derived from lab-based tests, it is very important to observe and consider all the specific landfill-site properties. The purpose of this study was to suggest and discuss the availability of batch and lysimeter tests to estimate the oxygen amount and the aeration period. To achieve this purpose, a comparison between lab test (batch and lysimeter tests) and full-scale applications was conducted. This study showed that aerobic batch and lysimeter tests could be used to estimate the amount of oxygen (mg-O2/g-DM) required to bio-stabilize landfilled wastes within a short period of time. In addition, aeration periods necessary to reach the target value can be calculated by a first-order kinetic depending on moisture content. Therefore, this study suggests that when applying in situ aeration processes to field-scale landfills, the amount of aeration required to bio-stabilize landfilled wastes has to be determined by the aerobic batch test, and then the aeration period required to reach the target value can be calculated by a reliable monitoring of the oxygen concentration in a landfill site in combination with the first-order kinetic.  相似文献   

14.
Most sludge has historically been disposed of in landfills and by ocean dumping but, because of its heavy metal content, this will be totally banned in Korea starting in 2012, based on the London Dumping Convention. Therefore, treatment and disposal methods that are environmentally friendlily are urgently required. The recycling of sewage sludge is a good treatment method for solving sludge problems in an environmentally friendly way. In this study, physical and environmental tests were conducted to evaluate the feasibility of using the by-products of thermal hydrolysis of sewage sludge as barrier layer materials in the final cover systems for landfills. In addition, testing methods for freezing-thawing (KS F 2332) and wetting-drying (KS F 2330) cycles were conducted to assess the effects of cold and hot soil climates starting from pavement. These tests yielded positive results for alternative materials for the barrier layer in a final cover system for a landfill.  相似文献   

15.
Several lysimeter scenarios and approaches exist to study the fate of agro-chemicals or contaminants from deposition in soil columns. In many systems just transport and leaching of the parent compound is followed, in some systems the leaching and transport of the metabolites is investigated as well. In more sophisticated lysimeter systems the volatilization and also the mineralization of the applied chemicals can be additionally monitored. Depending on the lysimeter system used and on the fact whether the applied chemicals are 14C-labeled or not, different results and various interpretations of the results might be achieved. Different lysimeter systems are described in this paper and a real dataset of a specific lysimeter experiment was transferred and evaluated in a virtual approach in the different lysimeter systems in order to show the advantages and disadvantages of the various systems.  相似文献   

16.
A compacted soil liner (CSL) has been widely used as a single barrier layer or a part of composite barrier layer in the landfill final cover system to prevent water infiltration into solid wastes for its acceptable hydraulic permeability. This study was conducted to test whether the CSL was also effective in prohibiting landfill gas emissions. For this purpose, three different compaction methods (i.e., reduced, standard, and modified Proctor methods) were used to prepare the soil specimens, with nitrogen as gas, and with water and heptane as liquid permeants. Measured gas permeability ranged from 2.03x10(-10) to 4.96x10(-9)cm(2), which was a magnitude of two or three orders greater than hydraulic permeability (9.60x10(-13) to 1.05x10(-11)cm(2)). The difference between gas and hydraulic permeabilities can be explained by gas slippage, which makes gas more permeable, and by soil-water interaction, which impedes water flow and then makes water less permeable. This explanation was also supported by the result that a liquid permeability measured with heptane as a non-polar liquid was similar to the intrinsic gas permeability. The data demonstrate that hydraulic requirement for the CSL is not enough to control the gas emissions from a landfill.  相似文献   

17.
In Europe, the use of direct methods using lysimeters for measuring water and solute flow in soils increased in recent years. Large weighable lysimeters are best suitable for obtaining reliable data about seepage water quantity and quality. Field lysimeters – lysimeters built in directly in agriculturally used areas – of high technical standard allow a precise determination of the influence of different cropping systems on groundwater quality. They combine the advantages of true field conditions and laboratory possibilities of varying parameters, handling and maintenance. Due to the specific needs of each application the instrumentation varies. Based on general remarks on the advantages of precise weighing lysimeters four standardized lysimeter configurations are presented. Beside the specific needs of design and setup of lysimeter stations, there is need to define general requirements to enable comparable results based on standardized basic design and to reduce individual mistakes.  相似文献   

18.
At the former uranium mining site of Ronneburg, large scale underground and open pit mining for nearly 40 years resulted in a production of about 113,000 tonnes of uranium and about 200 million cubic metres of mine waste. In their present state, these materials cause risks to human health and strong environmental impacts and therefore demand remedial action. The remediation options available are relocation of mine spoil into the open pit and on site remediation by landscaping/contouring, placement of a cover and revegetation. A suitable vegetated cover system combined with a surface water drainage system provides long-term stability against erosion and reduces acid generation thereby meeting the main remediation objectives which are long-term reduction of radiological exposure and contaminant emissions and recultivation. The design of the cover system includes the evaluation of geotechnical, radiological, hydrological, geochemical and ecological criteria and models. The optimized overall model for the cover system has to comply with general conditions as, e.g. economic efficiency, public acceptance and sustainability. Most critical elements for the long-term performance of the cover system designed for the Beerwalde dump are the barrier system and its long-term integrity and a largely self-sustainable vegetation.  相似文献   

19.
To prevent acid mine drainage arising from oxygen and water penetration of sulphide-rich mine tailings, the tailings are covered with layers of dry sealing material. Plant roots have a great ability to penetrate dense materials, and if the roots are able to penetrate the sealing layer of a tailings deposit, its oxygen-shielding properties could be reduced. The objective of this study was to evaluate whether plant roots are able to penetrate sealing layers covering mine tailings deposits. Root penetration into layers of various sealing materials, such as clayey moraine (clay, 8-10%; silt, 22-37%; sand, 37-55%; gravel, 15-18%), moraine (unspecified), 6-mm bentonite (kaolin clay) fabric, lime and clay, Cefyll (mixture of pulverized coal fly ash, cement and water) and a mixture containing biosludge (30-35%) and bioashes (65-70%), was investigated. In the field, roots were studied by digging trenches alongside vegetation growing in 3- and 10-year-old mine sites. In the greenhouse root growth of Betula pendula, Pinus sylvestris, Poa pratensis and Salix viminalis were studied in compartments where the plants had been growing for 22 months. The results from the field experiment indicated that roots are able to penetrate both deep down in the cover layer (1.7 m) and also into the sealing layers of various materials, and even to penetrate hard Cefyll. The addition of nutrients in the top cover reduced deep root growth and thereby also penetration through the sealing layer. Low hydraulic conductivity of the sealing layer or a thick cover layer had less effect on root penetration. In the greenhouse experiment roots did not penetrate the thin bentonite fabric, due to low pH (2.1-2.7) that was created from the underlying weathered mine tailings. The clayey moraine was penetrated by all species used in the greenhouse experiment; Pinus sylvestris had the greatest ability to penetrate. To prevent root penetration of the other sealing layer, a suitable condition for the plants should be created in the upper part of the cover layer, namely a sufficient amount of plant nutrients. However, to define such a condition is difficult since different plant species have different requirements.  相似文献   

20.
Large amounts of construction materials will be needed in Europe in anticipation for capping landfills that will be closed due to the tightening up of landfill legislation. This study was conducted to assess the potential environmental impacts of using refuse derived fuel (RDF) and municipal solid waste incineration (MSWI) ashes as substitutes for natural materials in landfill cover designs. The leaching of substances from a full-scale landfill cover test area built with different fly and bottom ashes was evaluated based on laboratory tests and field monitoring. The water that drained off above the liner (drainage) and the water that percolated through the liner into the landfill (leachate) were contaminated with Cl?, nitrogen and several trace elements (e.g., As, Cu, Mo, Ni and Se). The drainage from layers containing ash will probably require pre-treatment before discharge. The leachate quality from the ash cover is expected to have a minor influence on overall landfill leachate quality because the amounts generated from the ash covers were low, <3–30 l (m2 yr)?1. Geochemical modelling indicated that precipitation of clay minerals and other secondary compounds in the ash liner was possible within 3 years after construction, which could contribute to the retention of trace elements in the liner in the long term. Hence, from an environmental view point, the placement of ashes in layers above the liner is more critical than within the liner.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号