二氧化氟是一种具有广阔应用前景的饮用水消毒剂,制备和使用时可能产生一系列氯的不同氧化态物质,其中最主要的是ClO2、ClO2和ClO3,本研究用紫外分光光度法分别测定了ClO2和ClO2的含量,同时用改进的碘量法分别测定溶液中同时存在的ClO2、ClO2和ClO3,并讨论了有关的反应机理,测定的精密度和准确度均满足一般饮用水质分析的需要。  相似文献   

2.
受化工、造纸、农药等污染的地面水和加氯的自来水中含有氯酚类化合物。氯酚在水中的存在量达到PPb级浓度时,即会出现明显的恶臭味,由于这些化合物有致癌,致畸、致突变的潜在危险,美国环境保护局已把氯酚类化合物,列为水中优先分析的有机污染物。对于水中微量氯酚的测定,国内外文献报道中多数采用树脂富集,乙酸酐衍生化后,气相色谱法测定,但在富集树脂、色谱柱、富集和衍生化操作方法上颇具差异。作者用国产GDX-401树脂富集水中氯酚类化合物,在经过改装的  相似文献   

3.
水中微量五氯酚的气相色谱法测定   总被引:1,自引:0,他引:1  
提出GC-FCD分析方法测定水中微量五氯酚残留量。水样经萃取分离、衍生后,采用石油醚提取醋酸五氯酚酯,然后进入色谱柱,柱内填充2%OV-17+2%QF-1/ChromosorbW-HP(80~100目),柱温200℃,N_2流量80mL/min,五氯酚酯3min内出峰,最低检测浓度为0.1μg/L,各种样品回收率均在90%以上,样品测试结果满意,可用于多种水体中微量PCP残留量的测定。  相似文献   

4.
《水和废水监测分析方法 (第 3版 )》中载 ,阴离子洗涤剂用亚甲蓝分光光度法测定时 ,采用三氯甲烷多次重复萃取 ,最后定容 5 0mL ,测量吸光值。此法萃取工作量较大。现改为标准系列和水样相同操作 ,即采用 2 5mL三氯甲烷 1次萃取。用改进法和原方法对地表水样进行了对比测定 ,并对测定结果作t检验 ,检验表明两种方法之间无显著性差异。如此 ,改进法节省了时间和试剂 ,且提高了方法的灵敏度 ,尤其对低浓度的地表水水样更为适用。阴离子洗涤剂—亚甲蓝分光光度测定法的改进@郝永红$邯郸市环境监测中心站!河北邯郸056002 @宋宁$邯郸市…  相似文献   

5.
利用离子色谱法-抑制型电导检测了城市污水中的持久污染物高氯酸根,以IonPac AS20高容量强亲水阴离子交换柱分离,NaOH流动相等度淋洗,高氯酸根在12min内出峰。高氯酸根在0.01~50 mg/L内具有良好的线性,相关系数为0.9998,50μl进样时检出限可达到3μg/L。方法可用于多种城市污水中高氯酸根的监测,样品测定的标准相对偏差在0.60%~0.94%之间,加标回收率在97.3%~105.8%之间,具有较好的准确性和重现性。  相似文献   

6.
COD仪器快速测定法与标准法的比较   总被引:3,自引:0,他引:3  
介绍了HH-1型化学耗氧量测定仪快速测定COD的方法,实验结果表明此法在准确度,精度度方面与标准回流法具有可比性,它操作省时,试剂用量少,能自然显示COD值,对高含量,低含量水质均可测定,极适用于大批量样品的常规监测。  相似文献   

7.
余氯在pH6.5条件下与PADA发生显色反应,本文根据稳定悬浮颗粒对光的吸收行为研究选择波长测定水体中余氯,实验证明在450~515nm波长范围内任意选择两波长比色按照推导公式和模型计算余氯浓度,测定方便结果准确,且计算模型稳定,几乎不受操作环境影响。适合于废水和天然水的监测。  相似文献   

8.
水中酚类优先监测物的气相色谱测定法   总被引:1,自引:1,他引:1  
介绍测定环境水质中重点酚类污染物的色谱法,应用衍生化的前处理方法,分别采用填充柱和毛细管柱分离,氢焰检测器(FID)和电子捕获检测器(ECD)测定使用美国EPA的质量控制样品(QC),确定了方法的精密度和准确度.  相似文献   

9.
水中消毒副产物的监测方法研究进展   总被引:1,自引:0,他引:1       下载免费PDF全文
含氯、含氧等杀菌类消毒剂在饮用水生产、废水排放、再生水利用等环节应用广泛,会与水中的前驱物通过取代、氧化还原、水解、加成等反应形成种类繁多的消毒副产物(DBPs).DBPs的靶标监测基于已知DBPs的特性如挥发性、半挥发性、不挥发性等,采取相应的前处理和仪器分析方法;非靶标鉴别可对大量未知的DBPs进行筛查.综述了三卤...  相似文献   

10.
气相色谱/质谱法测定水中五氯酚   总被引:12,自引:0,他引:12       下载免费PDF全文
用GC/MS法测定环境水体和废水中的五氯酚 ,选择乙酸酐作衍生化试剂 ,二氯甲烷为萃取剂 ,比较了不同的衍生pH条件 ,以m/z为 2 6 6的定量特征离子定量 ,获得了较高的灵敏度和选择性  相似文献   

11.
氯气和二氧化氯气体共存时,用现有的分析方法不能分别测定,采用甲基橙比色法和硝酸银比浊法分别测定氯气和二氧化氯的总量,然后根据各自的反应原理和标准曲线方程建立二元一次方程组。通过求方程组的解,得到氯气和二氧化氯各自的含量,同时还研究了冷阱分离法,并对两种方法的测定结果进行了比较。  相似文献   

12.
In this work assays involving chlorinated water samples, which were previous spiked with humic substances or algae blue green and following the production of the THMs for 30 days is described. To implement the assays, five portions of 1,000 ml of water were stored in glass bottles. The water samples were treated with solutions containing 2, 3, 4 and 5 mg l−1 chlorine. The samples aliquots (60 ml) were transferred into the glass vials, 10 ml were removed to have a headspace and 100 μl of the 10 mg l−1 pentafluortoluene bromide solution was added to each vial. The extraction step was performed by adding 10 g of Na2SO4 followed by 5 ml of n-pentane. The vials were stopped with a TFE-faced septum and sealed with aluminum caps. The generated THMs were determined by gas chromatography with electron capture detector using reference solutions with concentration ranging from 8 to 120 μg l−1 THMs. Three assays were monitored during 30 days and chloroform was the predominant compound found in the water samples, while other species of THMs were not detected. The results showed that when the chlorine concentration was increased in water samples containing algae the concentration of THM varied randomly. Nevertheless, in water samples containing humic substances the increase of the THM concentration presented a relationship with the chlorine concentration. It was also observed that chloroform concentration increased with the elapsed time up to one and six days to water samples spiked with humic substances and algae blue green, respectively and decreased along 30 days. By other hand, assays performed using water samples containing decanted algae material showed that THM was not generated by the chlorine addition.  相似文献   

13.
系统研究了反应时间、水温、显色剂的用量及pH对游离性余氯测定的影响,优化选择最佳测定条件为控制水样pH〈8,水温25℃,显色剂用量2.5 ml,加入显色剂后立即比色测定游离性余氯。在此条件下,测定3种生活饮用水游离性余氯,回收率为96.7%~99.8%,测定结果与《生活饮用水标准检验法》(GB 5750-85)中37.3滴定法颇为一致。  相似文献   

14.
空气中氧化硫的测定对实验室测定条件比较敏感。通过实验表明显色时间,显色温度,盐酸副玫瑰苯胺纯度,蒸馏水质量等试验条件均对其校准曲线有影响,故在分析过程中,必须严格把握操作条件,遵循操作步骤。  相似文献   

15.
对测定水中硝基苯类化合物的锌还原-盐酸萘乙二胺分光光度法进行优化,简化了操作步骤,并将参加显色反应的水样体积由4.0 mL增加至8.0 mL,比色皿厚度由10 mm增加至20 mm,方法推荐检出限由0.20 mg/L降至0.05 mg/L,实验室检出限为0.042 mg/L,改进后的方法对标准样品的测定结果符合要求。  相似文献   

16.
根据化学需氧量测定原理和分析方法,推导出化学需氧量测定限,由测定限确定不同浓度废水化学需氧量测定的稀释倍数。  相似文献   

17.
水中油的测定方法探讨   总被引:10,自引:0,他引:10  
探讨了重量法,紫外光度法测定水中石油类的合适条件和动物油,植物油的干扰。按选定的操作方法测定,取得了满意结果。提供了一个处理石油醚的简单方法。  相似文献   

18.
吹气装置对水中硫化物测定的影响   总被引:1,自引:0,他引:1  
试验证实了硫化物吹气装置本身对测定很大的影响。改进的直筒悬挂式吹气装置是回收率高,重复性好等特点。S^2-〈0.2mg/L水样用此装置吹气分离,回收率可达0.2mg/L ̄0.8mg/L时,回收率也能达到93%以上,它是一种值得推广的吹气装置。  相似文献   

19.
对N,N-二乙基-1,4-苯二胺(DPD)分光光度法测游离氯的3个较权威的版本的操作步骤在显色效果、显色物稳定性、标准曲线和实测样品结果方面进行了对比,对<水质游离氯和总氯的测定N,N-二乙基-1,4-苯二胺分光光度法>(GB 11898-1989)操作步骤提出了一点改进建议.  相似文献   

20.
研制了一种测定水中Mg2 + 的测试管 ,测定范围为 0 .5mg/L~ 2 .0mg/L。该测试管适用于现场应急监测 ,具有快速、简便、抗干扰能力强和价格低廉等特点  相似文献   