首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
底泥中多环芳烃的处理技术进展   总被引:3,自引:0,他引:3  
底泥中多环芳烃(PAHs)的处理方法主要有物化处理和生物处理。物化处理方法有湿式空气氧化、溶剂浸提、热解吸等;生物处理有好氧处理和厌氧处理。物化处理速度快、效果明显,但能耗高、投资大;生物处理方法虽然能耗低,但速度慢、降解率较低。实际运用中宜发展物化和生物的组合工艺。  相似文献   

2.
Occurrence and fate of heavy metals in the wastewater treatment process   总被引:19,自引:0,他引:19  
The occurrence and the fate of heavy metals (Cd, Pb, Mn, Cu, Zn, Fe and Ni) during the wastewater treatment process were investigated in the wastewater treatment plant (WTP) of the city of Thessaloniki, northern Greece, operating in the activated sludge mode. For this purpose, wastewater and sludge samples were collected from six different points of the plant, namely, the influent (raw wastewater, RW), the effluent of the primary sedimentation tank (primary sedimentation effluent, PSE), the effluent of the secondary sedimentation tank (secondary sedimentation effluent, SSE), sludge from the primary sedimentation tank (primary sludge, PS), activated sludge from the recirculation stream (activated sludge, AS), and the digested/dewatered sludge (final sludge, FS).

The distribution of metals between the aqueous and the solid phase of wastewater was investigated. Good exponential correlation was found between the metal partition coefficient, logKp, and the suspended solids concentration. The mass balance of heavy metals in the primary, secondary and the whole treatment process showed good closures for all metal species. The relative distribution of individual heavy metals in the treated effluent and the sludge streams indicated that Mn and Cu are primarily (>70%) accumulated in the sludge, while 47–63% of Cd, Cr, Pb, Fe, Ni and Zn remain in the treated effluent.  相似文献   


3.
We created a database in order to quantitatively assess the occurrence and removal efficiency of pharmaceuticals and personal care products (PPCPs) in wastewater treatment plants (WWTPs). From 117 scientific publications, we compiled 6641 data covering 184 PPCPs. Data included the concentrations of PPCPs in WWTP influents and effluents, their removal efficiency and their loads to the aquatic environment. The first outputs of our database allowed to identify the most investigated PPCPs in WWTPs and the most persistent ones, and to obtain reliable and quantitative values on their concentrations, frequency of detection and removal efficiency in WWTPs. We were also able to compare various processes and pointed out activated sludge with nitrogen treatment and membrane bioreactor as the most efficient ones.  相似文献   

4.
Wang J  McPhedran KN  Seth R  Drouillard KG 《Chemosphere》2007,69(11):1802-1806
Screening level risk assessment models are used by many countries to assess the treatability of organic chemicals during the sewage treatment process, especially those that are new to commerce. The performance of one such model, the sewage treatment plant model, is evaluated in the current study by comparing model predictions with actual measurement data collected at various stages of a typical full-scale activated sludge type sewage treatment plant. A suite of ten polycyclic aromatic hydrocarbons (PAHs) with widely varying physico–chemical properties were monitored for the comparison. Model predicted removal efficiencies were in very good agreement with those measured for all ten PAHs. Observed chemical concentrations and their trends at various stages of the sewage treatment process were also well simulated by the model. Results also suggest that a reasonable first approximation estimate of a range for the biodegradation half-life needed for the model may be obtained by dividing reported aqueous biodegradation half-life by scaling factors of 50 and 150.  相似文献   

5.
The self-organising map approach was used to assess the efficiency of chlorinated solvent removal from petrochemical wastewater in a refinery wastewater treatment plant. Chlorinated solvents and inorganic anions (11 variables) were determined in 72 wastewater samples, collected from three different purification streams. The classification of variables identified technical solvents, brine from oil desalting and runoff sulphates as pollution sources in the refinery, affecting the quality of wastewater treatment plant influent. The classification of samples revealed the formation of five clusters: the first three clusters contained samples collected from the drainage water, process water and oiled rainwater treatment streams. The fourth cluster consisted mainly of samples collected after biological treatment, and the fifth one of samples collected after an unusual event. SOM analysis showed that the biological treatment step significantly reduced concentrations of chlorinated solvents in wastewater.  相似文献   

6.
A survey on the presence of pharmaceuticals in urban wastewater of a Spanish Mediterranean area (Castellon province) was carried out. The scope of the study included a wide variety of pharmaceuticals belonging to different therapeutical classes. For this purpose, 112 samples, including influent and effluent wastewater, from different conventional wastewater treatment plants were collected. Two monitoring programmes were carried out along several seasons. The first was in June 2008 and January 2009, and the second in April and October 2009. During the first monitoring, the occurrence of 20 analytes in 84 urban wastewater samples (influent and effluent) was studied. The selection of these pharmaceuticals was mainly based on consumption. From these, 17 compounds were detected in the samples, with analgesics and anti-inflammatories, cholesterol lowering statin drugs and lipid regulators being the most frequently detected groups. 4-Aminoantipyrine, bezafibrate, diclofenac, gemfibrozil, ketoprofen, naproxen and venlafaxine were the compounds most frequently found. In the highlight of these results, the number of analytes was increased up to around 50. A lot of antibiotic compounds were added to the target list as they were considered “priority pharmaceuticals” due to their more potential hazardous effects in the aquatic environment. Data obtained during the second monitoring programme (spring and autumn) corroborated the results from the first one (summer and winter). Analgesics and anti-inflammatories, lipid regulators together with quinolone and macrolide antibiotics were the most abundant pharmaceuticals. Similar median concentrations were found over the year and seasonal variation was not clearly observed. The removal efficiency of pharmaceuticals in the wastewater treatment plants was roughly evaluated. Our results indicated that elimination of most of the selected compounds occurred during the treatment process of influent wastewater, although it was incomplete.  相似文献   

7.
Zhang W  Wei C  Chai X  He J  Cai Y  Ren M  Yan B  Peng P  Fu J 《Chemosphere》2012,88(2):174-182
The occurrence, behaviors and fate of 18 PAHs were investigated in a coking wastewater treatment plant in Songshan coking plant, located in Shaoguan, Guangdong Province of China. It was found that the target compounds occurred widely in raw coking wastewater, treated effluent, sludge and gas samples. In raw coking wastewater, high molecular weight (MW) PAHs were the dominant compounds, while 3-6 ring PAHs predominated in the final effluent. The dominant compounds in gas samples were phenathrene, fluoranthene and pyrene, while they were fluoranthene, pyrene, chrysene and benzo[k]fluoranthene for sludge. The process achieved over 97% removal for all the PAHs, 47-92% of eliminations of these target compounds in liquid phase were achieved in biological stage. Different behaviors of PAHs were observed in the primary tank, anaerobic tank, aerobic tank, hydrolytic tank and coagulation tank units, while heavier and lower ones were mainly removed in anaerobic tank and aerobic tanks, respectively. Regarding the fate of PAHs, calculated fractions of mass losses for low MW PAHs due to transformation and adsorption to sludge accounted for 15-50% and 24-49%, respectively, while the rest was less than 1%. For high MW PAHs, the mass losses were mainly due to adsorption to sludge and separation with tar (contributing 56-76% and 22-39%, respectively), and the removal through transformation was less.  相似文献   

8.
Gao P  Ding Y  Li H  Xagoraraki I 《Chemosphere》2012,88(1):17-24
Occurrence and removal efficiencies of fifteen pharmaceuticals were investigated in a conventional municipal wastewater treatment plant in Michigan. Concentrations of these pharmaceuticals were determined in both wastewater and sludge phases by a high-performance liquid chromatograph coupled to a tandem mass spectrometer. Detailed mass balance analysis was conducted during the whole treatment process to evaluate the contributing processes for pharmaceutical removal. Among the pharmaceuticals studied, demeclocycline, sulfamerazine, erythromycin and tylosin were not detected in the wastewater treatment plant influent. Other target pharmaceuticals detected in wastewater were also found in the corresponding sludge phase. The removal efficiencies of chlortetracycline, tetracycline, sulfamerazine, acetaminophen and caffeine were >99%, while doxycycline, oxytetracycline, sulfadiazine and lincomycin exhibited relatively lower removal efficiencies (e.g., <50%). For sulfamethoxazole, the removal efficiency was approximately 90%. Carbamazepine manifested a net increase of mass, i.e. 41% more than the input from the influent. Based on the mass balance analysis, biotransformation is believed to be the predominant process responsible for the removal of pharmaceuticals (22% to 99%), whereas contribution of sorption to sludge was relatively insignificant (7%) for the investigated pharmaceuticals.  相似文献   

9.
脱木素工艺为中小制浆企业的黑液治理提供了新的方法。系统中酸化纤维污泥减小碱木素胶粒间的斥力 ,吸附废水中已析出的木质素和细小纤维 ;酸破坏了系统中胶体的水化膜 ,增大了胶体的粒径 ;混凝剂中和胶体表面电荷 ,增加颗粒间的接触机会 ,同时发挥了絮凝沉降的作用。该工艺与传统工艺相比 ,减少了酸及混凝剂的用量 ,木素沉降速度快。当试验废水pH =5、绝干纤维污泥与进水CODCr质量之比为 1.1、硫酸铝投加量为 160mg/L时 ,CODCr去除率高于 63 %。  相似文献   

10.
磁粉强化活性污泥法处理餐饮废水的研究   总被引:17,自引:0,他引:17  
磁粉强化活性污泥化是在常规活性污泥法中加入适量强磁性粉末的废水生物处理方法。研究了用磁粉活性污泥法净化处理餐饮废水,通过与普通活性污泥法的平行试验,结果表明,磁粉强化活性污泥法适宜的磁粉加入量为700mg/L儿,磁粉粒度<1μm,CODcr去除率和出水透光率都优于普通活性污泥法,活性污泥氮体结构和沉降性能明显改善。  相似文献   

11.
《Environmental Forensics》2013,14(3-4):227-241
The successful application of forensic geology to contamination studies involving natural systems requires identification of appropriate endmembers and an understanding of the geologic setting and processes affecting the systems. Studies attempting to delineate the background, or natural, source for hydrocarbon contamination in Gulf of Alaska (GOA) benthic sediments have invoked a number of potential sources, including seep oils, source rocks, and coal. Oil seeps have subsequently been questioned as significant sources of hydrocarbons present in benthic sediments of the GOA in part because the pattern of relative polycyclic aromatic hydrocarbon (PAH) abundance characteristic of benthic GOA sediments is inconsistent with patterns typical of weathered seep oils. Likewise, native coal has been dismissed in part because ratios of labile hydrocarbons to total organic carbon (e.g. PAH: TOC) for Bering River coal field (BRCF) sources are too low--i.e. the coals are over mature--to be consistent with GOA sediments. We present evidence here that native coal may have been prematurely dismissed, because BRCF coals do not adequately represent the geochemical signatures of coals elsewhere in the Kulthieth Formation. Contrary to previous thought, Kulthieth Formation coals east of the BRCF have much higher PAH: TOC ratios, and the patterns of labile hydrocarbons in these low thermal maturity coals suggest a possible genetic relationship between Kulthieth Formation coals and nearby oil seeps on the Sullivan anticline. Analyses of low-maturity Kulthieth Formation coal indicate the low maturity coal is a significant source of PAH. Source apportionment models that neglect this source will underestimate the contribution of native coals to the regional background hydrocarbon signature.  相似文献   

12.
Li X  Ke Z  Dong J 《Chemosphere》2011,82(5):635-638
The levels of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) were analyzed by an isotope-dilution high-resolution mass spectrometric in 16 sewage sludges, sampled from 2004 to 2009, from two municipal wastewater treatment plants (WWTPs) in Beijing. Total toxicity equivalent (TEQ) values were evaluated using the toxicity equivalent factors proposed by International for PCDD/Fs. The I-TEQs for these sewage sludges were from 0.97 to 15.0 pg g−1 dry weight (dw) with a mean value 4.43 pg g−1 dw, indicating that all I-TEQs were below Chinese legislation limit value regulated for agricultural use in soils.The results from limited samples (16 samples) showed that the levels of PCDD/Fs might be correlated with the sludge age. Meanwhile, the temporal trends of PCD/Fs suggested that the I-TEQs may correlate with rainfall in the present study.  相似文献   

13.
Sim WJ  Lee JW  Shin SK  Song KB  Oh JE 《Chemosphere》2011,82(10):1448-1453
We measured five estrogens in the wastewater samples from the municipal wastewater treatment plants (M-WWTPs), livestock wastewater treatment plants (L-WWTPs), hospital WWTPs (H-WWTPs) and pharmaceutical manufacture WWTPs (P-WWTPs) in Korea. The L-WWTPs showed the highest total concentration (0.195-10.4 μg L−1) of estrogens in the influents, followed by the M-WWTPs (0.028-1.15 μg L−1), H-WWTPs (0.068-0.130 μg L−1) and P-WWTPs (0.015-0.070 μg L−1). Like the influents, the L-WWTPs (0.003-0.729 μg L−1) and the M-WWTPs (0.001-0.299 μg L−1) also showed higher total concentration of estrogens in the effluents than the H-WWTPs (0.002-0.021 μg L−1) and P-WWTPs (0.011 μg L−1 in one sample). The L-WWTPs (37.5-543 μg kg−1, dry weight) showed higher total concentrations in sludge than the M-WWTPs (3.16-444 μg kg−1, dry weight) like the wastewater. The distribution of estrogens in the WWTPs may be affected by their metabolism in the human body, their transition through biological treatment processes, and their usage for livestock growth. Unlike the concentration results, the daily loads of estrogens from the M-WWTPs were the highest, which is related to the high capacities of WWTPs.  相似文献   

14.
Impacts of flooding on the soil environment with regard to soil pollution with polycyclic aromatic hydrocarbons and s‐triazine (cyanazine, simazine, atriazine, propazine, prometryn) herbicides have been evaluated. No clear differences in the sum of the PAHs content were observed in the present studies. Only changes in the levels of individual PAHs were noted. In soils covered with flooding both at a depth of 0–20 and 20–40 high molecular weight PAHs were predominant (especially mutagenic and carcinogenic 5‐rings PAHs) whereas in non‐flooded areas, 2‐ and 3‐rings PAHs constituted over 80%. In the case of s‐triazine herbicides, no influence of flooding on the changes in their content in agriculturally used soils was noted. On the other hand, clearly lower levels of cyanazine, simazine and atriazine were not in the flooded forest soil as compared to the non‐flooded forest soil.  相似文献   

15.
张羽  孙力平  钟远 《环境工程学报》2016,10(4):1681-1687
城市污水处理厂作为城市污水处理的重要承担者,其处理能力不足势必会对下游水体产生严重影响,也给水体的再生利用带来了难度,污水处理厂的去除效率变得尤为关注。以2014年3-12月天津市某污水处理厂氮的监测数据为基础,对其脱氮效率进行了评价。结果表明:污水处理厂脱氮效率偏低,总氮平均去除率为55.61%,且出水仅达到二级排放标准(GB 18918-2002),水厂进水C/N、水温对总氮的去除效率影响很大;水厂氨氮的平均去除率为87.40%,其去除率受进水NH4+-N浓度影响很大,水厂对高浓度的进水NH4+-N(大于70 mg/L)去除效率偏低,而进水NH4+-N小于60 mg/L时,出水NH4+-N基本能满足一级A排放标准(GB 18918-2002);水厂出水的亚硝态氮含量很高,其主要受溶解氧和C/N的影响;水厂对有机氮的去除效果不佳,需要采用深度处理技术。  相似文献   

16.
陈嵘  刘茵  李俊炎 《环境工程学报》2016,10(12):7093-7098
基于西安市污水处理厂出水一级A达标排放的要求,对西安市某污水处理厂A2/O工艺运行效果进行监测分析,结果表明,该污水处理厂出水总磷一级A达标率仅为31.61%,出水总磷浓度偏高成为该污水处理厂一级A达标的限制因素。通过对污水处理厂现场调研与水质沿程监测分析发现,该污水处理厂污泥水中含有大量SS和TP,此部分污泥水回流至系统前端导致生物池进水总磷浓度急剧升高,生物池超负荷运行导致出水总磷偏高。同时由于生物池碳源不足,厌氧池释磷作用微弱,影响了系统的除磷效果。针对以上问题,进行了初沉池运行方式调整、强化污泥处理、出水增设滤池等一系列改造措施。改造后系统除磷效果明显提高,出水TP降低至(0.39±0.08)mg·L-1,基本可以达到一级A排放标准。  相似文献   

17.
介绍了美国某污水处理厂的处理工艺流程、主要构筑物构成及其设计参数,通过对该污水处理厂一年内运行效果的调研,分析评价了该污水厂的进出水水质指标;该水厂工艺流程对TSS、BOD5、COD、NH3-N、TP和浊度的年平均去除率分别可以达到97.7%、97.7%、93.5%、82.6%、95.2%和97.9%,各项出水水质均优于我国《城镇污水处理厂污染物排放标准》(GB18918-2002)一级A标准,通过对该水厂工艺的介绍和分析,为我国污水厂的建设及改造升级提供了一定的参考依据.  相似文献   

18.
Goal, Scope and Background Dissolved organic carbon (DOC) constitutes a parameter of organic pollution for waters and wastewaters, which is not so often studied, and it is not yet regulated by directives. The term ‘DOC’ is used for the fraction of organics that pass through a 0.45 μm pores’ size membrane. The type of wastewater plays an important role in the quality of DOC and it has been shown that DOC may contain aquatic humic substances, hydrophobic bases, hydrophobic neutrals, hydrophilic acids, hydrophilic bases and hydrophilic neutrals. The quality of the DOC is expected to affect its fate in a wastewater treatment plant (WWTP), since a considerable fraction of DOC is not biodegradable, and it may be released in the aquatic environment together with the treated effluent. In the present study, the occurrence of DOC during the wastewater treatment process is investigated and its removal rates during primary, secondary and overall treatment are being estimated. Furthermore, a correlation is being attempted between DOC and the concentrations of selected Persistent Organic Pollutants (POPs) and Heavy Metals (HMs) in the dissolved phase of wastewaters, to examine whether there are common sources for these pollution parameters in WWTPs. Also, DOC is being correlated with the partition coefficients of the above-mentioned pollutants in wastewater, in order to examine the effect of ‘solubility enhancement’ in WWTPs and to evaluate the result of this phenomenon in the efficiency of a WWTP to remove organic pollutants. Methods For the purposes of this study, 24-h composite wastewater samples were collected from the influent (raw wastewater, RW), the effluent of primary sedimentation tank (primary sedimentation effluent, PSE) and the effluent of secondary sedimentation tank (secondary sedimentation effluent, SSE). Samples were analyzed for the presence of 26 POPs (7 PCBs and 19 organochlorine pesticides), 8 HMs and DOC. Results and Discussion Mean concentrations of DOC in RW and PSE were at similar levels (∼ 70 mg l−1), suggesting that primary treatment has a minor effect on the DOC content of wastewater. DOC concentrations in SSE were significantly lower (∼ 19 mg l−1) as a result of the degradation of organic compounds in the biological reactor. Calculated removals of DOC were 0.8% in the primary treatment, 63% in the secondary treatment, and 69% in the overall treatment, exhibiting large differences from other organic pollution parameters, such as BOD and COD. The overall DOC removal was found to be independent from the DOC concentration in raw wastewater. Poor correlation was also observed between the DOC content and the concentrations of wastewater contaminants, such as persistent organic pollutants (POPs) and heavy metals (HMs), probably suggesting that their occurrence in WWTPs is due to different sources. A good negative linear relationship was revealed between DOC concentrations and the logarithms of the distribution coefficients (K d) of various POPs and HMs between the solid and the liquid phases of wastewater. This relationship suggests that DOC facilitates hydrophobic pollutants to remain in the dissolved phase thus causing lower removal percentages during the treatment process. Conclusion DOC was measured at three stages of a municipal WWTP that receives mainly domestic wastewater and urban runoff. DOC concentrations in untreated and primarily treated wastewater were almost equal, and only after the secondary sedimentation there was a decrease. Concentrations and removal rates of DOC were in the same levels as in other WWTPs that receive municipal wastewater. The origin of DOC was found to be different to the one of POPs and of HMs, as no correlation was observed between the concentrations of DOC and the concentrations of these pollutants. On the contrary, DOC was found to have significant negative correlation with the K d of all pollutants examined, suggesting that it plays an important role in the partitioning of those pollutants between the dissolved and the sorbed phase of wastewaters. This effect of DOC on partitioning can affect the ability of WWTPs to remove toxic pollutants, and that way it facilitates the discharge of those chemicals in the aquatic ecosystems together with the treated effluent. Recommendation By the results of this work it is shown that the presence of DOC in wastewaters can significantly affect the partition of hazardous pollutants between the dissolved and the sorbed phase. It is therefore of importance that this parameter is controlled more in wastewaters, since it can cause a decrease in the efficiency of WWTPs to remove quantitatively persistent pollutants.  相似文献   

19.
针对不同形态氮类营养物在城市污水处理系统中迁移转化机理尚不明确这一问题,通过现场监测和实验室模拟分析,研究不同形态氮类营养物在整个城市污水处理系统(A/A/O工艺)中的转化特性。研究结果表明,在原污水总氮中溶解态氮和颗粒态氮比例相当,浓度分别为39.28 mg/L和41.24 mg/L,无机氮是溶解态氮的主要成分,比例占93.2%(36.61 mg/L),而有机氮含量极少,仅为2.67 mg/L。在颗粒态氮中有机氮比重很大,约占96.58 %(39.83 mg/L)。在整个一级处理过程中溶解态氮变化量很小,而颗粒态有机氮减少了45%,总氮降低主要是由于颗粒态有机氮通过沉淀作用去除而实现的。现场监测和模拟实验结果表明,溶解性有机氮在厌氧区和缺氧区中由于被厌氧微生物降解而大幅度减少,而在好氧区却有一定程度的增加。二级出水中的氮主要还是以无机氮为主,可通过进一步优化工艺参数来强化系统硝化/反硝化作用,去除污水中残留的无机氮。  相似文献   

20.
根据昆明市第一污水处理厂深度处理微絮凝-D型滤池工艺的运行数据,评价了工艺出水水质及总磷(TP)去除效果,同时分析了混凝剂投加量及药剂费用。结果表明,微絮凝-D型滤池工艺出水TP平均浓度为0.15 mg/L,最优水平值为0.05 mg/L,95%保证值为0.37 mg/L,TP平均去除率为63.6%。出水悬浮固体(SS)浓度95%保证值为10 mg/L。混凝剂聚合氯化铝(PAC)的投加量在1.5~4 mg Al2O3/L范围波动,去除单位TP的PAC投加量平均值为16.7 mg Al2O3/mg-P,投加比为2~8 mol-Al/mol-P。当投加比超过5时,出水TP浓度可达到0.3 mg/L以下。吨水PAC成本平均值为0.017元/t。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号