首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 581 毫秒
1.
Long-term field comparisons of continuous and integrated filter measurements of mass concentrations of particulate matter (PM) with an aerodynamic diameter less than or equal to 2.5 microm (PM2.5) were performed at rural and urban sites in New York State. Two versions of the continuous tapered element oscillating microbalance (TEOM) mass monitor are deployed at each site, in addition to Federal Reference Method filter samplers. Data are grouped into monthly averages to retain and demonstrate seasonal differences. Strong seasonal dependence is observed-the TEOM monitors with the heated sensors are biased systematically low with respect to the Federal Reference Method measurements during the cold season. For the rural site, the average bias for the sample equilibration system (SES)-equipped and standard TEOM monitors is 14 and 24%, respectively. At this location, the TEOM monitor measurements were biased low for all 34 months. For the urban site, the average bias for the SES and standard TEOM monitors is 8 and 18%, respectively. At this location, the TEOM monitor measurements are as likely to be biased high as low during the warm-season months. The hour averaged data from the two versions of the TEOM monitor are also compared, and also indicate that the SES-equipped version of the TEOM monitor captures 7-11% more PM2.5 mass at these locations.  相似文献   

2.
Fine particulate matter (PM2.5) concentrations associated with 202 24-hr samples collected at the National Energy Technology Laboratory (NETL) particulate matter (PM) characterization site in south Pittsburgh from October 1999 through September 2001 were used to apportion PM2.5 into primary and secondary contributions using Positive Matrix Factorization (PMF2). Input included the concentrations of PM2.5 mass determined with a Federal Reference Method (FRM) sampler, semi-volatile PM2.5 organic material, elemental carbon (EC), and trace element components of PM2.5. A total of 11 factors were identified. The results of potential source contributions function (PSCF) analysis using PMF2 factors and HYSPLIT-calculated back-trajectories were used to identify those factors associated with specific meteorological transport conditions. The 11 factors were identified as being associated with emissions from various specific regions and facilities including crustal material, gasoline combustion, diesel combustion, and three nearby sources high in trace metals. Three sources associated with transport from coal-fired power plants to the southeast, a combination of point sources to the northwest, and a steel mill and associated sources to the west were identified. In addition, two secondary-material-dominated sources were identified, one was associated with secondary products of local emissions and one was dominated by secondary ammonium sulfate transported to the NETL site from the west and southwest. Of these 11 factors, the four largest contributors to PM2.5 were the secondary transported material (dominated by ammonium sulfate) (47%), local secondary material (19%), diesel combustion emissions (10%), and gasoline combustion emissions (8%). The other seven factors accounted for the remaining 16% of the PM2.5 mass. The findings are consistent with the major source of PM2.5 in the Pittsburgh area being dominated by ammonium sulfate from distant transport and so decoupled from local activity emitting organic pollutants in the metropolitan area. In contrast, the major local secondary sources are dominated by organic material.  相似文献   

3.
The impact of various atmospheric transport directions on ambient fine particle (PM2.5) concentrations at several sites in southeastern Canada was estimated (for May-September) using back-trajectory analysis. Three-day back trajectories (four per day) were paired with 6-hr average PM2.5 mass concentrations measured using tapered element oscillating microbalances (TEOM). PM2.5 concentrations at rural locations in the region were affected by nonlocal sources originating in both Canada and the United States. Comparison of sites revealed that, on average, the local contribution to total PM2.5 in the greater Toronto area (GTA) is approximately 30-35%. At each location, average PM2.5 concentrations under south/southwesterly flow conditions were 2-4 times higher than under the corresponding northerly flow conditions. The chemical composition of both urban and rural PM2.5 was determined during two separate 2-week spring/summer measurement campaigns. Components identified included SO4(2-) NO3-, NH4+, black carbon and organic carbon (OC), and trace elements. Higher particle mass at the urban Toronto site was composed of a higher proportion of all components. However, black carbon, NO3-, NaCl, and trace elements were found to be the most enriched over the rural/regional background levels.  相似文献   

4.
The results from a chemical characterization study of fine particulate matter (PM2.5) measured at three elementary schools in Central and Southeast Ohio is presented here. PM2.5 aerosol samples were collected from outdoor monitors and indoor samplers at each monitoring location during the period of February 1, 1999, through August 31, 2000. The locations included a rural elementary school in Athens, OH, and two urban schools within Columbus, OH. The trace metal and ionic concentrations in the collected samples were analyzed using an X-ray fluorescence spectrophotometer and ion chromatography unit, respectively. Sulfate ion was found to be the largest component present in the samples at all three of the sites. Other abundant components included nitrate, chloride, ammonium, and sodium ions, as well as calcium, silicon, and iron. The average PM2.5 concentrations showed similar temporal variations among the three sites within the study region. PM2.5 and its major component, sulfate ion, showed strong seasonal variations with maximum concentrations observed during the summer at all three of the sites. The indoor environment was found to be more contaminated during the spring months (March through May) at New Albany (a suburb of Columbus, OH) and East Athens (rural Ohio area). Potential source contribution function analysis showed that particulate matter levels at the monitoring sites were affected by transport from adjoining urban areas and industrial complexes located along the Ohio River Valley. A preliminary outdoor source apportionment using the principal component analysis (PCA) technique was performed. The results from the PCA suggest that the study region was primarily impacted by industrial, fossil fuel combustion, and geological sources. The 2002 emissions inventory data for PM2.5 compiled by Ohio Environmental Protection Agency also showed impacts of similar source types, and this was used to validate the PCA analysis.  相似文献   

5.
Fine particulate matter (PM2.5) mass was determined on a continuous basis at the Salt Lake City Environmental Protection Agency Environmental Monitoring for Public Awareness and Community Tracking monitoring site in Salt Lake City, UT, using three different monitoring techniques. Hourly averaged PM2.5 mass data were collected during two sampling periods (summer 2000 and winter 2002) using a real-time total ambient mass sampler (RAMS), sample equilibration system (SES)-tapered element oscillating microbalance (TEOM), and conventional TEOM monitor. This paper compares the results obtained from the various monitoring systems, which differ in their treatment of semivolatile material (SVM; particle-bound water, semivolatile ammonium nitrate, and semivolatile organic compounds). PM2.5 mass results obtained by the RAMS were consistently higher than those obtained by the SES-TEOM and conventional TEOM monitors because of the RAMS ability to measure semivolatile ammonium nitrate and semivolatile organic material but not particle-bound water. The SES-TEOM monitoring system was able to account for an average of 28% of the SVM, whereas the conventional TEOM monitor loses essentially all of the SVM from the single filter during sampling. Occasional mass readings by the various TEOM monitors that are higher than RAMS results may reflect particle-bound water, which, under some conditions, is measured by the TEOM but not the RAMS.  相似文献   

6.
The tapered element oscillating microbalance (TEOM) is one type of continuous ambient particulate matter (PM) monitor. Adsorption and desorption of moisture and semivolatile species may cause positive or negative artifacts in TEOM PM mass measurement. The objective of this field study was to investigate possible uncertainties associated with TEOM measurements in the poultry operation environment. For comparisons of TEOM with filter-based gravimetric method, four instruments (TEOM-PM10, low-volume PM10 sampler TEOM-PM2.5, and PM2.5 speciation sampler) were collocated and tested inside a poultry house for PM2.5 and PM10 (PM with aerodynamic equivalent diameter < or =2.5 and < or =10 microm, respectively) measurements. Fifteen sets of 24-hr PM10 concentrations and 13 sets of 24-hr PM2.5 measurements were obtained. Results indicate that compared with filter-based gravimetric method, TEOM gave significantly lower values of both PM10 and PM2.5 mass concentrations. For PM10, the average ratio of TEOM to the gravimetric method was 0.936. For PM2.5, the average ratio of TEOM to the gravimetric method was 0.738. Particulate matter in the poultry houses possibly contains semivolatile compounds and moisture due to high levels of relative humidity (RH) and gas pollutants. The internal heating mechanism of the TEOM may cause losses in mass through volatilization. To investigate the effects of TEOM settings on concentration measurements, the heaters of two identical TEOMs were set at 50 degrees C, 30 degrees C, or no heating at all. They were collocated and tested for total suspended particle (TSP), PM10, and PM25 measurements in layer house for 6 weeks. For all TSR PM10, and PM2.5 measurements, the internal TEOM temperature setting had a significant effect (P < 0.05). Significantly higher PM mass concentrations were measured at lower temperature settings. The effects of environmental (i.e., temperature, RH, NH3 and CO2 concentrations) and instrumental (i.e., filter loading and noise) parameters on PM measurements were also assessed using regression analysis.  相似文献   

7.
Gaseous and particulate pollutant concentrations associated with five samples per day collected during a July 2001 summer intensive study at the Pittsburgh Carnegie Mellon University (CMU) Supersite were used to apportion fine particulate matter (PM2.5) into primary and secondary contributions using PMF2. Input to the PMF2 analysis included the concentrations of PM2.5 nonvolatile and semivolatile organic material, elemental carbon (EC), ammonium sulfate, trace element components, gas-phase organic material, and NO(x), NO2, and O3 concentrations. A total of 10 factors were identified. These factors are associated with emissions from various sources and facilities including crustal material, gasoline combustion, diesel combustion, and three nearby sources high in trace metals. In addition, four secondary sources were identified, three of which were associated with secondary products of local emissions and were dominated by organic material and one of which was dominated by secondary ammonium sulfate transported to the CMU site from the west and southwest. The three largest contributors to PM2.5 were secondary transported material (dominated by ammonium sulfate) from the west and southwest (49%), secondary material formed during midday photochemical processes (24%), and gasoline combustion emissions (11%). The other seven sources accounted for the remaining 16% of the PM2.5. Results obtained at the CMU site were comparable to results previously reported at the National Energy Technology Laboratory (NETL), located approximately 18 km south of downtown Pittsburgh. The major contributor at both sites was material transported from the west and southwest. Some difference in nearby sources could be attributed to meteorology as evaluated by HYSPLIT model back-trajectory calculations. These findings are consistent with the majority of the secondary ammonium sulfate in the Pittsburgh area being the result of contributions from distant transport, and thus decoupled from local activity involving organic pollutants in the metropolitan area. In contrast, the major local secondary sources were dominated by organic material.  相似文献   

8.
The particulate matter (PM) concentration and composition, the PM10, PM2.5, PM1 fractions, were studied in the urban area of Genoa, a coastal town in the northwest of Italy. Two instruments, the continuous monitor TEOM and the sequential sampler PARTISOL, were operated almost continuously on the same site from July 2001 to September 2004. Samples collected by PARTISOL were weighted to obtain PM concentration and then analysed by PIXE (particle induced X-ray emission) and by ED-XRF (energy dispersion X-ray fluorescence), obtaining concentrations for elements from Na to Pb. Some of the filters used in the TEOM microbalance were analysed by ED-XRF to calculate Pb concentration values averaged over 7-30 d periods.  相似文献   

9.
Continuous monitoring of particulate matter (PM) with a diameter less than 2.5 microm (PM2.5) is quickly gaining acceptance as an alternative means of measuring fine PM in the United States. For this project, data were taken from all monitoring sites within Region 5 that used the tapered element oscillating microbalance (TEOM) for PM2.5 and had a collocated Federal Reference Method (FRM) monitor. Scatter plots of TEOM versus FRM show that for a significant fraction of the observations, an independent factor causes the TEOM to underestimate the FRM value. This underestimation appears to increase as temperature decreases. For this analysis, a linear relationship was fit to the TEOM versus FRM data, allowing a break or knot in the relationship, modeled as a change of slope, at a site-specific temperature. To test whether the models are adequate for adjusting future measurements, models were also developed using the first year of data only, and the remaining observations were used to test the durability of the relationships. For all but one monitor in Minnesota, the models developed for each site had consistently high R2s, were predictive of future measurements, and could be used to derive "FRM-like" results from the TEOM measurements. The temperature knots fitted by the model for individual sites ranged from 12.9 to 20.6 degrees C. Data from all six sites in the state of Michigan were also combined to determine if a single model could be developed for the entire state. While the single model for the state of Michigan worked reasonably well, some of the predicted concentrations at individual sites were systematically underestimating the observed concentrations on more polluted days. The same conclusion was drawn for a Region 5-wide model. This approach was also found to work very well for six individual TEOM monitors in New York State.  相似文献   

10.
Apportionment of primary and secondary pollutants during the summer 2001 Pittsburgh Air Quality Study (PAQS) is reported. Several sites were included in PAQS, with the main site (the supersite) adjacent to the Carnegie Mellon University campus in Schenley Park. One of the additional sampling sites was located at the National Energy Technology Laboratory, located approximately 18 km southeast of downtown Pittsburgh. Fine particulate matter (PM2.5) mass, gas-phase volatile organic material (VOM), particulate semivolatile and nonvolatile organic material (NVOM), and ammonium sulfate were apportioned at the two sites into their primary and secondary contributions using the U.S. Environmental Protection Agency UNMIX 2.3 multivariate receptor modeling and analysis software. A portion of each of these species was identified as originating from gasoline and diesel primary mobile sources. Some of the organic material was formed from local secondary transformation processes, whereas the great majority of the secondary sulfate was associated with regional transformation contributions. The results indicated that the diurnal patterns of secondary gas-phase VOM and particulate semivolatile and NVOM were not correlated with secondary ammonium sulfate contributions but were associated with separate formation pathways. These findings are consistent with the bulk of the secondary ammonium sulfate in the Pittsburgh area being the result of contributions from distant transport and, thus, decoupled from local activity involving organic pollutants in the metropolitan area.  相似文献   

11.
Outdoor and indoor fine particulate species were measured at the Lindon Elementary School in Lindon, Utah, to determine which components of ambient fine particles have strong indoor and outdoor concentration correlations. PM2.5 mass concentrations were measured using tapered element oscillating microbalance (TEOM) monitors and by gravimetric analysis of Teflon filter samples. Gas-phase HNO3, sulfur dioxide, particulate nitrate, strong acid, and particulate sulfate were measured using annular denuder samplers. Soot was measured using quartz filters in filter packs. Total particulate number was measured with a condensation nucleus counter (CNC). Total particulate number and fine particulate sulfate and soot were correlated for ambient and indoor measurements. Indoor PM2.5 mass showed a low correlation with outdoor PM2.5 mass because of the influence of coarse material from student activities on indoor PM2.5. Fine particle acidity and the potentiation of biological oxidative mechanisms by iron were not correlated indoors and outdoors.  相似文献   

12.
Abstract

Increased interest in the health effects of ambient par–ticulate mass (PM) has focused attention on the evaluation of existing mass measurement methodologies and the definition of PM in ambient air. The Rupprecht and Patashnick Tapered Element Oscillating MicroBalance (TEOM®) method for PM is compared with time–integrated gravimetric (manual) PM methods in large urban areas during different seasons. Comparisons are conducted for both PM10 and PM2.5 concentrations.

In urban areas, a substantial fraction of ambient PM can be semi–volatile material. A larger fraction of this component of PM10 may be lost from the TEOM–heated filter than the Federal Reference Method (FRM). The observed relationship between TEOM and FRM methods varied widely among sites and seasons. In East Coast urban areas during the summer, the methods were highly correlated with good agreement. In the winter, correlation was somewhat lower, with TEOM PM concentrations generally lower than the FRM. Rubidoux, CA, and two Mexican sites (Tlalnepantla and Merced) had the highest levels of PM10 and the largest difference between TEOM and manual methods.

PM2.5 data from collocation of 24–hour manual samples with the TEOM are also presented. As most of the semi–volatile PM is in the fine fraction, differences between these methods are larger for PM2.5 than for PM10.  相似文献   

13.
Abstract

Long-term field comparisons of continuous and integrated filter measurements of mass concentrations of par-ticulate matter (PM) with an aerodynamic diameter less than or equal to 2.5 μm (PM2.5) were performed at rural and urban sites in New York State. Two versions of the continuous tapered element oscillating microbalance (TEOM) mass monitor are deployed at each site, in addition to Federal Reference Method filter samplers. Data are grouped into monthly averages to retain and demonstrate seasonal differences. Strong seasonal dependence is observed—the TEOM monitors with the heated sensors are biased systematically low with respect to the Federal Reference Method measurements during the cold season. For the rural site, the average bias for the sample equilibration system (SES)-equipped and standard TEOM monitors is 14 and 24%, respectively. At this location, the TEOM monitor measurements were biased low for all 34 months. For the urban site, the average bias for the SES and standard TEOM monitors is 8 and 18%, respectively. At this location, the TEOM monitor measurements are as likely to be biased high as low during the warm-season months. The hour averaged data from the two versions of the TEOM monitor are also compared, and also indicate that the SES-equipped version of the TEOM monitor captures 7-11% more PM2.5 mass at these locations.  相似文献   

14.
重庆主城区春季典型天气的大气颗粒物浓度变化分析   总被引:4,自引:2,他引:2  
选取重庆大气超级站2010年春季典型天气时段的颗粒物实时监测数据,将β射线法和震荡天平法(TEOM法)的PM10监测值进行了比对,分析了PM10、PM2.5和PM1质量浓度百分比例关系及10μm以下颗粒物数浓度随粒径大小的分布规律。结果表明,β射线法与TEOM法的PM10监测结果基本一致,β射线法比TEOM法监测值平均偏低5.4%;PM2.5、PM1和PM0.5的数浓度均占PM10数浓度的98%以上;PM0.25数浓度占PM10数浓度的平均比例为34.9%,占PM1数浓度的平均比例为35.1%;TEOM法监测的PM2.5占PM10日均质量浓度平均比例为51.2%;β射线法监测的PM2.5占PM10日均质量浓度平均比例为56.9%,PM1占PM10平均比例为30.9%。  相似文献   

15.
Deployment of continuous analyzers in the Southeastern Aerosol Research and Characterization Study (SEARCH) network began in 1998 and continues today as new technologies are developed. Measurement of fine particulate matter (PM2.5) mass is performed using a dried, 30 degrees C tapered element oscillating microbalance (TEOM). TEOM measurements are complemented by observations of light scattering by nephelometry. Measurements of major constituents include: (1) SO4(2-) via reduction to SO2; (2) NH4+ and NO3- via respective catalytic oxidation and reduction to NO, (3) black carbon (BC) by optical absorption, (4) total carbon by combustion to CO2, and (5) organic carbon by difference between the latter two measurements. Several illustrative examples of continuous data from the SEARCH network are presented. A distinctive composite annual average diurnal pattern is observed for PM2.5 mass, nitrate, and BC, likely indicating the influence of traffic-related emissions, growth, and break up of the boundary layer and formation of ammonium nitrate. Examination of PM2.5 components indicates the need to better understand the continuous composition of the unmeasured "other" category, because it contributes a significant fraction to total mass during periods of high PM2.5 loading. Selected episodes are presented to illustrate applications of SEARCH data. An SO2 conversion rate of 0.2%/hr is derived from an observation of a plume from a coal-fired power plant during early spring, and the importance of local, rural sources of NH3 to the formation of ammonium nitrate in particulate matter (PM) is demonstrated.  相似文献   

16.
As part of an international research project, aerosol samples were collected by several filter-based devices on Nuclepore polycarbonate membrane, Teflon membrane and quartz fibre filters over separate daylight periods and nights, and on-line aerosol measurements were performed by TEOM and aethalometer within an urban canyon (kerbside) and at a near-city background site in Budapest, Hungary from 23 April–5 May 2002. Aerosol masses in PM2.0, PM10–2.0, PM2.5, PM10 size fractions and of TSP were determined gravimetrically; atmospheric concentrations of organic (OC) and elemental carbon (EC) for PM2.5 (or PM2.0), PM10 fractions and for TSP were measured by thermal–optical transmission method. Repeatability of the mass determination by Nuclepore filters seems to be 5–6%. Collections on Teflon filters yielded smaller mass on average by 8(±12)% than that for the Nuclepore filters. Quartz filters overestimated the PM10 mass in comparison with the Nuclepore filters due primarily to sampling artefacts on average by 10(±16)% at the kerbside. Tandem filter set-ups were utilised for correcting the sampling artefacts for OC by subtraction method. At the kerbside, the aerosol mass was made up on average of 35(±4)% of organic matter (OM) in the PM10 fraction, while the contribution of OM to the PM2.5 mass was 43(±9)%. At the background, OM also accounted for 43(±13)% of the PM2.0 mass. On average, EC made up 14(±6)%, 7(±2)% and 4.5(±1.1)% of the mass in the PM2.5, PM10 fractions and TSP, respectively, at the kerbside; while its contribution was only 2.1(±0.5)% in the PM2.0 fraction in the near-city background. Temporal variability for PM mass, OC and EC concentrations was related to road traffic, local meteorology and long-range transport of air masses. It was concluded that a direct coupling between the atmospheric concentration levels and vehicle circulation can be identified within the urban canyon, nevertheless, the local meteorology in particular and long-range transport of air masses have much more influence on the air quality than changes in the source intensity of road traffic. Concentration ratios of OC/EC were evaluated, and the amount of secondary organic aerosol (SOA) was estimated by using EC as tracer for the primary OC emissions. Mean contribution and standard deviation of the SOA to the OM in the PM2.5 size fraction at the kerbside over daylight periods and nights were of 37(±18) and 46(±16)%, respectively.  相似文献   

17.
ABSTRACT

Canadian particle monitoring programs examining PM10, PM2.5, and particle composition have been in operation for over 10 years. Until recently, the measurements were manual/filter-based with 24-hr sample collection varying in frequency from daily to every sixth day, using GrasebyAnderson dichotomous samplers. In the past few years, these monitoring activities have been expanded to include hourly measurements using tapered element oscillating microbalances (TEOMs). This continuous monitoring program started operation focusing on PM10, but now emphasizes PM2.5 through the addition of more TEOMs and switching of the inlets of some of the existing units. The data from all of these measurement activities show that there are broad geographical differences and also local- to regional-scale spatial differences in mass and composition of PM2.5. Due to variations in sources, significantly different PM2.5 concentrations are not uncommon within the same city. Comparison of nearby urban and rural sites indicates that 30 and 40% of the PM2.5 is from local urban sources in Montreal and Toronto, respectively. Hourly PM2.5 measurements in Toronto suggest that vehicular emissions are an important contributor to urban PM2.5. There has been a decreasing trend in urban PM2.5, with annual average concentrations between the 1987–1990 and 1993–1995 periods decreasing by 11 to 39%, depending upon the site. The largest declines were in Montreal and Halifax, and the smallest decline was in Toronto. Comparison of 24-hr TEOM and manual dichotomous sampler PM2.5 measurements from a site in Toronto indicates that the TEOM results in lower concentrations. The magnitude of this difference is relatively small in the warmer months, averaging about 12%. During the colder months the difference averages about 23%, but can be as large as 50%.  相似文献   

18.
Field evaluations and comparisons of continuous fine particulate matter (PM2,5) mass measurement technologies at an urban and a rural site in New York state are performed. The continuous measurement technologies include the filter dynamics measurement system (FDMS) tapered element oscillating microbalance (TEOM) monitor, the stand-alone TEOM monitor (without the FDMS), and the beta attenuation monitor (BAM). These continuous measurement methods are also compared with 24-hr integrated filters collected and analyzed under the Federal Reference Method (FRM) protocol. The measurement sites are New York City (the borough of Queens) and Addison, a rural area of southwestern New York state. New York City data comparisons between the FDMS TEOM, BAM, and FRM are examined for bias and seasonality during a 2-yr period. Data comparisons for the FDMS TEOM and FRM from the Addison location are examined for the same 2-yr period. The BAM and FDMS measurements at Queens are highly correlated with each other and the FRM. The BAM and FDMS are very similar to each other in magnitude, and both are approximately 25% higher than the FRM filter measurements at this site. The FDMS at Addison measures approximately 9% more mass than the FRM. Mass reconstructions using the speciation trends network filter data are examined to provide insight as to the contribution of volatile species of PM2.5 in the FDMS mass measurement and the fraction that is likely lost in the FRM mass measurement. The reconstructed mass at Queens is systematically lower than the FDMS by approximately 10%.  相似文献   

19.
Speciated fine particulate matter (PM2.5) data collected as part of the Speciation Trends Network at four sites in the Midwest (Detroit, MI; Cincinnati, OH; Indianapolis, IN; and Northbrook, IL) and as part of the Interagency Monitoring of Protected Visual Environments program at the rural Bondville, IL, site were analyzed to understand sources contributing to organic carbon (OC) and PM2.5 mass. Positive matrix factorization (PMF) was applied to available data collected from January 2002 through March 2005, and seven to nine factors were identified at each site. Common factors at all of the sites included mobile (gasoline)/secondary organic aerosols with high OC, diesel with a high elemental carbon/OC ratio (only at the urban sites), secondary sulfate, secondary nitrate, soil, and biomass burning. Identified industrial factors included copper smelting (Northbrook, Indianapolis, and Bondville), steel/manufacturing with iron (Northbrook), industrial zinc (Northbrook, Cincinnati, Indianapolis, and Detroit), metal plating with chromium and nickel (Detroit, Indianapolis, and Bondville), mixed industrial with copper and iron (Cincinnati), and limestone with calcium and iron (Bondville). PMF results, on average, accounted for 96% of the measured PM2.5 mass at each site; residuals were consistently within tolerance (+/-3), and goodness-of-fit (Q) was acceptable. Potential source contribution function analysis helped identify regional and local impacts of the identified source types. Secondary sulfate and soil factors showed regional characteristics at each site, whereas industrial sources typically appeared to be locally influenced. These regional factors contributed approximately one third of the total PM2.5 mass, on average, whereas local mobile and industrial sources contributed to the remaining mass. Mobile sources were a major contributor (55-76% at the urban sites) to OC mass, generally with at least twice as much mass from nondiesel sources as from diesel. Regional OC associated with secondary sulfate and soil was generally low.  相似文献   

20.
Federally funded, multistate field studies were initiated in 2002 to measure emissions of particulate matter (PM) < 10 microm (PM10) and total suspended particulate (TSP), ammonia, hydrogen sulfide, carbon dioxide, methane, nonmethane hydrocarbons, and odor from swine and poultry production buildings in the United States. This paper describes the use of a continuous PM analyzer based on the tapered element oscillating microbalance (TEOM). In these studies, the TEOM was used to measure PM emissions at identical locations in paired barns. Measuring PM concentrations in swine and poultry barns, compared with measuring PM in ambient air, required more frequent maintenance of the TEOM. External screens were used to prevent rapid plugging of the insect screen in the PM10 preseparator inlet. Minute means of mass concentrations exhibited a sinusoidal pattern that followed the variation of relative humidity, indicating that mass concentration measurements were affected by water vapor condensation onto and evaporation of moisture from the TEOM filter. Filter loading increased the humidity effect, most likely because of increased water vapor adsorption capacity of added PM. In a single layer barn study, collocated TEOMs, equipped with TSP and PM10 inlets, corresponded well when placed near the inlets of exhaust fans in a layer barn. Initial data showed that average daily mean concentrations of TSP, PM10, and PM2.5 concentrations at a layer barn were 1440 +/- 182 microg/m3 (n = 2), 553 +/- 79 microg/m3 (n = 4), and 33 +/- 75 microg/m3 (n = 1), respectively. The daily mean TSP concentration (n = 1) of a swine barn sprinkled with soybean oil was 67% lower than an untreated swine barn, which had a daily mean TSP concentration of 1143 +/- 619 microg/m3. The daily mean ambient TSP concentration (n = 1) near the swine barns was 25 +/- 8 microg/m3. Concentrations of PM inside the swine barns were correlated to pig activity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏