首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Emission factors for PCDD/PCDF determined from open combustion are used to estimate national emission budgets; therefore, it is important to have confidence in their accuracy. It has been suspected that artefacts may form due to the presence of hot metal surfaces of sampling equipment, thus skewing emission factors. In this study, emissions of PCDD/PCDF from open burning of forest biomass over a brick hearth were sampled. Five experiments were carried out using a portable sampler. Experiments were designed where the key variable, sample hood and inlet temperatures were manipulated. Other variables such as fuel origin, type and density were consistent. The measured concentration of PCDD/PCDF in the smoke samples ranged from 0.01 μg TEQ (t fuel)−1 at the lowest maximum hood temperature (185 °C) to 15 μg TEQ (t fuel)−1 at the highest maximum hood temperature (598 °C). when hood inlet temperatures exceeded 400 °C emission factors were significantly elevated and this is attributed to the formation of artefacts that can cause the over estimation of emission factors. The increase in hood temperature also resulted in a change in the PCDD/PCDF congener and homologue profile of the emissions. For example at the lowest temperature (Fire 1) the PCDD/PCDF ratio measured was 50:1, whereas at the highest temperature (Fire 5) this ratio was about 0.53:1. When the sampler hood and inlet temperatures were kept in the normal operating range of <200 °C, emission factors were comparable to those observed in many previous studies in Australia with emissions dominated by PCDD.  相似文献   

2.
Polychlorinated dibenzo-p-dioxin and dibenzofuran (PCDD/PCDF) were overall measured and compared in ambient air, water, soils, and sediments along the upper reaches of the Haihe River of North China, so as to evaluate their concentrations, profiles, and to understand the processes of gas–particle partitioning and air–water/soil exchange. The following results were obtained: (1) The average concentrations (toxic equivalents, TEQs) of 2,3,7,8-PCDD/PCDF in air, water, sediment, and soil samples were 4,855 fg/m3, 9.5 pg/L, 99.2 pg/g dry weight (dw), and 56.4 pg/g (203 fg TEQ/m3, 0.46 pg TEQ/L, 2.2 pg TEQ/g dw, and 1.3 pg TEQ/g, respectively), respectively. (2) Although OCDF, 1,2,3,4,6,7,8-HpCDF, OCDD, and 1,2,3,4,6,7,8-HpCDD were the dominant congeners among four environmental sinks, obvious discrepancies of these congener and homologue patterns of PCDD/PCDF were observed still. (3) Significant linear correlations for PCDD/PCDF were observed between the gas–particle partition coefficient (K p) and the subcooled liquid vapor pressure (P L 0) and octanol–air partition coefficient (K oa). (4) Fugacity fraction values of air–water exchange indicated that most of PCDD/PCDF homologues were dominated by net volatilization from water into air. The low-chlorinated PCDD/PCDF (tetra- to hexa-) presented a strong net volatilization from the soil into air, while high-chlorinated PCDD/PCDF (hepta- to octa-) were mainly close to equilibrium for air–soil exchange.  相似文献   

3.
The concentrations of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), dioxin-like polychlorinated biphenyls (dl-PCBs) and polybrominated diphenylethers (PBDEs) in 33 breast milk samples collected in 2006-2007 from primipara mothers close to four industrial areas of Slovak Republic were determined. The total PCDDs/PCDFs and dl-PCBs expressed as TEQ based on WHO TEFs 1998 in breast milk samples varied from 5.0 to 51.8 pg g−1 fat (median: 13.1 pg g−1 fat; mean: 18.0 pg g−1 fat). The measurements of seven PBDE congeners (IUPAC No. 28, 47, 99, 100, 153, 154, and 183) were performed for the first time in human milk from Slovakia. PBDE levels ranged between 0.22 and 1.62 ng g−1 fat, with median and mean value of 0.43 ng g−1 fat and 0.57 ng g−1 fat respectively. No statistically significant differences were observed between studied areas in total PBDE concentrations.Furthermore, this study presents first results concerning the daily intake (DI) of PCDDs/PCDFs and dioxin-like compounds for the most vulnerable breast-fed infant population in Slovakia. The total PCDD/PCDF and dl-PCB DI for an infant during the first 2 months of life was estimated in a range from 14.4 to 230 pg TEQ kg−1 b.w., with a median value of 58.9 pg TEQ kg−1 b.w.. The DI values substantially exceeded the tolerable daily intake (TDI) 1-4 pg TEQ kg−1 b.w. recommended by WHO. The dietary infant intake concerning PBDEs was estimated to be between 0.69 and 7.1 ng kg−1 b.w. d−1, with median value of 1.7 ng kg−1 b.w. d−1.  相似文献   

4.
Since current estimates of hexachlorobenzene (HCB), polychlorinated biphenyls (PCB), dioxins (PCDD) and furans (PCDF) from ships are based on a relatively limited and old data set, an update of these emission factors has been outlined as a target towards improved Swedish emission inventories. Consequently, a comprehensive study was undertaken focusing on these emissions from three different ships during December 2003 to March 2004. Analyses were performed on 12 exhaust samples, three fuel oil samples and three lubricating oil samples from a representative selection of diesel engine models, fuel types and during different “real-world” operating conditions.The determined emissions corresponded reasonably well with previous measurements. The data suggest however that previous PCDD/PCDF emission factors are somewhat higher than those measured here. As expected the greatest emissions were observed during main engine start-up periods and for engines using heavier fuel oils. Total emissions for 2002, using revised emission factors, have been calculated based on Swedish sold marine fuels and also for geographical areas of national importance. In terms of their toxic equivalence (WHO-TEQ), the PCDD/PCDF emissions from ships using Swedish fuels are small (0.37–0.85 g TEQ) in comparison to recent estimates for the national total (ca. 45 g TEQ). Emissions from other land-based diesel engines (road vehicles, off-road machinery, military vehicles and locomotives) are estimated to contribute a further 0.18–0.42 g TEQ. Similarly, HCB and PCB emissions from these sources are small compared to 1995 national emission inventories.  相似文献   

5.
This report presents results of emission measurements of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) in the flue gas of seven oil, nine gas, and two wood firing systems under laboratory conditions. The burn rate of the combustion was in the range of the rated useful heat output. Two additional test series varied the amount of combustion air and thus the heat output. The PCDD/PCDF emissions for oil- and gas-fired boilers are in the range of 0.0020-0.0142 ng I-TEQ/m3 (referring to 3% O2 in the dry flue gas). No correlation between the combustion technique and the PCDD/PCDF emissions could be established. In the tests with the wood-fired furnaces PCDD/PCDF concentrations in the flue gas ranging from 0.014 to 0.076 ng I-TEQ/m3 (referring to 13% O2 in the dry flue gas) were found. A significant correlation between the firing rate of the heating insert and the measured PCDD/PCDF concentrations was found. On examination of three typical 2,3,7,8-CDD/CDF congener profiles, a comparable pattern could be observed with natural gas and light fuel oil. The congener distribution for wood combustion is considerably different.  相似文献   

6.
PCDD/PCDF,chlorinated pesticides and PAH in Chinese teas   总被引:5,自引:0,他引:5  
Fiedler H  Cheung CK  Wong MH 《Chemosphere》2002,46(9-10):1429-1433
Four samples of Chinese tea (two green teas, and two brick teas) were analyzed for their concentrations of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/PCDF), chlorinated pesticides and PAH. The infusions prepared from these teas were also analyzed for PCDD/PCDF. The levels of DDT and its metabolites in tea leaves were within the safety limit of 0.2 mg/kg. Rather high levels of total PAH were obtained in brick tea (1048–1162 mg/kg), when compared with green tea (497–517 mg/kg). In terms of PCDD/PCDF, the concentrations of green tea and brick tea differed by a factor of 16, while the concentrations of all infusions were within a factor of 2. The dioxin concentrations in green tea leaves can be explained through uptake of atmospheric PCDD/PCDF. The higher concentrations in the brick tea leaves are due the longer exposure time, and to certain extent, the use of old leaves, branches and roots when making the tea, and additional components such as soil particulates through contamination. Certain Chinese populations drinking a large amount of brick tea (>3 l per day) indicated that individuals of these populations consume more tea than Europeans or North Americans result in a comparably higher intake of PCDD/PCDF. Tea consumption can attribute to up to 10% of the TDI recommended by WHO (only PCDD/PCDF considered, no PCB analyzed).  相似文献   

7.
Taking into account current environmental concerns, the main objective of this work focused a national inventory aiming to estimate the amount of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/PCDF) released in Portugal in 2006. The methodology used was based on the Standardized Toolkit for Identification and Quantification of Dioxins and Furan Releases, developed by UNEP Chemicals, in 2005. The method allows the assessment of the amount of PCDD/PCDF released into the environment along five vectors involving air, water, land, products and residues. Facing some difficulties mainly regarding to the availability of data for some activities known to produce PCDD/PCDF, three scenarios (Sc1 to Sc3) corresponding to lower, central and upper estimates were established. The Sc1 scenario (lower estimate) includes the situations where in case of doubt or scarce information, reduced or none emission values were assumed, Sc2 refers to a central estimate, which is believed to be the most realistic for the Portuguese situation, while Sc3 corresponds to the worst case (upper estimate). The results obtained pointed out that the total amount of PCDD/PCDF emitted in Portugal during the period under analysis was in the range of 51.2-217.9 g TEQ year−1, with the most likely value of 95.2 g TEQ year−1 achieved under the Sc2 scenario. This study also showed that the methodology developed by UNEP Chemicals is a very simple one, and the main difficulty is the availability of data. The main indicators calculated in this study were 8.98 μg TEQ/(year person) by taking into account the total amount of PCDD/PCDF released, and 3.63 μg TEQ/(year person) when only air emissions were considered.  相似文献   

8.
The concentrations, compositional profiles, and possible sources of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/PCDF) in water column and surface sediment samples from the lower reaches of the Yangtze River were investigated, and the potential risks posed by these chemicals were evaluated. Concentrations of the 17 2,3,7,8-substituted PCDD/PCDF in the water and sediment samples ranged from 0.45 to 10.0 pg TEQ/L (mean 2.34 pg TEQ/L) and from 0.31 to 51 pg TEQ/g dw (mean 5.25 pg TEQ/g dw), respectively. Water and sediments from the Nanjing–Nantong sections of the Yangtze River were found to have elevated PCDD/PCDF levels, and the PCDD/PCDF TEQ concentrations in 13 sediment samples exceeded the probable effect levels (PEL), above which adverse biological effects are likely. Multivariate statistical analysis indicated that the principal PCDD/PCDF contamination source for the water and sediment was the production and use of pentachlorophenol (PCP) or sodium pentachlorophenate (PCP-Na). PCDD/PCDF concentrations were stable over time near the Yangtze River Estuary but had increased sharply in recent decades in the Nanjing–Nantong section, which will have been related to the growth in industrial activities and other anthropogenic PCDD/PCDF sources. Total organic carbon (TOC) and PCDD/PCDF concentrations correlated significantly (R?=?0.474, P?<?0.01), suggesting that TOC plays an important role in the transport and re-distribution of PCDD/PCDF in the Yangtze River basin.  相似文献   

9.
Bulk depositions and surface soil were collected in a suburban area, near the Adriatic Sea, in order to assess the contribution of a municipal solid waste incinerator to the area’s total contamination with polychlorinated dibenzodioxins and polychlorinated dibenzofurans (PCDDs and PCDFs). Samples were collected at two sites, situated in the area most affected by plant emissions (according to the results of the Calpuff air dispersion model), and at an external site, considered as a reference. Results show that the studied area is subject to low contamination, as far as these compounds are concerned. Deposition fluxes range from 14.3 pg m−2 d−1 to 89.9 pg m−2 d−1 (0.75 pg-TEQ m−2 d−1 to 3.73 pg-TEQ m−2 d−1) and no significant flow differences are observed among the three monitored sites. Total soil concentration amounts to 93.8 ng kg−1 d.w. and 1.35 ng-TEQ kg−1 d.w, on average, and confirms a strong homogeneity in the studied area. Furthermore, from 2006 to 2009, no PCDD/Fs enrichment in the soil was noticed. Comparing the relative congener distributions in environmental samples with those found in stack emissions from the incineration plant, significant differences are observed in the PCDD:PCDF ratio and in the contribution of the most chlorinated congeners. From this study we can conclude that the incineration plant is not the main source of PCDD/Fs in the studied area, which is apparently characterized by a homogeneous and widespread contamination situation, typical of an urban area.  相似文献   

10.
《Chemosphere》2012,86(11):1749-1758
Taking into account current environmental concerns, the main objective of this work focused a national inventory aiming to estimate the amount of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/PCDF) released in Portugal in 2006. The methodology used was based on the Standardized Toolkit for Identification and Quantification of Dioxins and Furan Releases, developed by UNEP Chemicals, in 2005. The method allows the assessment of the amount of PCDD/PCDF released into the environment along five vectors involving air, water, land, products and residues. Facing some difficulties mainly regarding to the availability of data for some activities known to produce PCDD/PCDF, three scenarios (Sc1 to Sc3) corresponding to lower, central and upper estimates were established. The Sc1 scenario (lower estimate) includes the situations where in case of doubt or scarce information, reduced or none emission values were assumed, Sc2 refers to a central estimate, which is believed to be the most realistic for the Portuguese situation, while Sc3 corresponds to the worst case (upper estimate). The results obtained pointed out that the total amount of PCDD/PCDF emitted in Portugal during the period under analysis was in the range of 51.2–217.9 g TEQ year−1, with the most likely value of 95.2 g TEQ year−1 achieved under the Sc2 scenario. This study also showed that the methodology developed by UNEP Chemicals is a very simple one, and the main difficulty is the availability of data. The main indicators calculated in this study were 8.98 μg TEQ/(year person) by taking into account the total amount of PCDD/PCDF released, and 3.63 μg TEQ/(year person) when only air emissions were considered.  相似文献   

11.
There is a lack of information regarding persistent organic pollutants (POPs) in soil from Slovakia. This paper reports the concentrations of 17 polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), 12 dioxin-like polychlorinated biphenyls (dl-PCBs) and 6 indicator PCBs associated with 32 soil samples collected in 2007 from areas in the vicinity up to several kilometres from four selected industrial PCDD/F sources in Slovakia and one background area.The results show that the total WHO1998-PCDD/F/dl-PCB-TEQ concentrations varied from 0.34 to 18.05 pg g−1 dry weight (dw) and the average total TEQ concentrations in samples collected at the Šala, Košice, Krompachy and Dubová areas were 3.18, 2.64, 7.80, and 3.19 pg g−1 dw respectively. The average of the total WHO1998-TEQ values in three soil samples representing the background Starina area was 0.66 pg g−1 dw. The predominant contaminants among 2,3,7,8-substituted PCDD/Fs, dl-PCB, and indicator PCBs was OCDD, PCB 118, and PCB 153 respectively. The major contributors to the TEQ were 2,3,4,7,8-PeCDF, PCB 126, 1,2,3,7,8-PeCDD, PCB 156 and 1,2,3,4,7,8-HxCDF + 1,2,3,4,7,9-HxCDF in descending order.  相似文献   

12.
Open burning for waste disposal is, in many countries, the dominant source of polychlorinated dibenzodioxins, dibenzofurans and biphenyls (PCDD/PCDF/PCB) release to the environment. To generate emission factors for open burning, experimental pile burns of about 100 kg of household waste were conducted with emissions sampling. From these experiments and others conducted by the same authors it is found that less compaction of waste or active mixing during the fire - “stirring” - promotes better combustion (as evidenced by lower CO/CO2 ratio) and reduces emissions of PCDD/PCDF/PCB; an intuitive but previously undemonstrated result. These experiments also support previous results suggesting PCDD/PCDF/PCB generation in open burning - while still highly variable - tends to be greater in the later (smoldering) phases of burning when the CO/CO2 ratio increases.  相似文献   

13.
Significant dioxin (polychlorinated dibenzo-para-dioxins (PCDDs)/polychlorinated dibenzo-furans (PCDFs)) pollution from a municipal solid waste incinerator was discovered in 1997 in Osaka prefecture/Japan. The cause and mechanism of pollution was identified by a detailed assessment of the environment and incinerator plant. The primary sources of PCDD/PCDF pollution were high dioxin releases from an intermittently operated waste incinerator with PCDD/PCDF emissions of 150 ng-TEQ/Nm3. PCDD/PCDF also accumulated in the wet scrubber system (3,000 μg TEQ/L) by adsorption and water recirculation in the incinerator. Scrubber water was air-cooled with a cooling tower located on the roof of the incinerator. High concentrations of dioxins in the cooling water were released as aerosols into the surrounding and caused heavy soil pollution in the area near the plant. These emissions were considered as the major contamination pathway from the plant. Decontamination and soil remediation in and around the incinerator plant were conducted using a variety of destruction technologies (including incineration, photochemical degradation and GeoMelt technology). Although the soil remediation process was successfully finished in December 2006 about 3 % of the waste still remains. The case demonstrates that releases from incinerators which do not use best available technology or which are not operated according to best environmental practices can contaminate their operators and surrounding land. This significant pollution had a large impact on the Japanese government’s approach toward controlling dioxin pollution. Since this incident, a ministerial conference on dioxins has successfully strengthened control measures.  相似文献   

14.
Hsu JF  Guo HR  Wang HW  Liao CK  Liao PC 《Chemosphere》2011,83(10):1353-1359
Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) are unintentional byproducts of combustion and industrial processes. Firefighters face the risk of occupational exposure to PCDD/Fs. Congener-specific analyses of 17 PCDD/Fs were performed on 20 serum samples collected from firefighters and fire scene investigators, and four soot samples that had deposited on the surfaces of the fire helmets and were collected after the firefighters had fought fires. The PCDD/F concentrations on the helmets that were contaminated by being worn at the fire scenes were 63-285 times higher than those on a clean helmet. The median serum PCDD/F concentration of the 16 firefighters (12 pg WHO2005-TEQ g−1 lipid) was not different from those of the males from the general Taiwanese population (9.4 pg WHO2005-TEQ g−1 lipid). However, the median PCDD/F level in the four fire scene investigators (15 pg WHO2005-TEQ g−1 lipid) was higher than those in the male from the general Taiwanese population (Mann-Whitney U test, p < 0.01). Furthermore, the serum samples from the firefighters and fire scene investigators, and the soot samples from the fire scenes presented similarly distinctive PCDD/F profiles that had elevated proportions for 10 PCDF congeners. Limited data indicated that the fire scene investigators were occupationally exposed to PCDD/Fs at the fire scenes. We suggested that the firefighters were not occupationally exposed to PCDD/Fs at the fire scenes due to appropriate protection. However, the fire scene investigators may have had more occupational exposure to PCDD/Fs due to poor protection, and further research must be performed to confirm this.  相似文献   

15.
Ogura I  Masunaga S  Nakanishi J 《Chemosphere》2001,44(6):1473-1487
The atmospheric bulk (dry and wet) deposition of dioxins was investigated at four locations (Tokyo, Yokohama, Tsukuba, and Tanzawa) in the Kanto region (in Japan) over one year using a stainless-steel pot. Annual average polychlorinated dibenzo-p-dioxins/polychlorinated dibenzofurans (PCDD/PCDF) deposition fluxes were estimated to be from 450 to 1300 ng/m2/yr, and the annual average TEQ fluxes from 5.7 to 17 ng-TEQ/m2/yr at the four locations. The PCDD/PCDF deposition flux was higher in winter than in summer. The deposition flux could be related to ambient temperature, particularly for less chlorinated PCDDs/PCDFs, while the deposition flux is not necessarily related to the amount of precipitation. The PCDD/PCDF deposition flux increased as the particle deposition flux increased, for the winter samples. Based on the ratio of the PCDD/PCDF deposition fluxes to the particle deposition fluxes, the contribution of the reentrainment of soil particles to the TEQ of PCDD/PCDF deposition was considered to be negligible in this region. Based on the air concentrations monitored near our deposition sampling points by the municipalities, the ratio of the annual deposition flux to the annual average air concentration was roughly estimated to be 0.082 cm/s. The range of deposition flux in the Kanto region was estimated to be from 1.5 to 31 (median: 9.8) ng-TEQ/m2/yr based on the range of air concentration data measured by the municipalities. The total annual deposition flux in the entire Kanto region was estimated to range from 50 to 900 g-TEQ/yr (median 320 g-TEQ/yr). This estimated flux was of the same order as the sum of estimated emissions from municipal solid waste incinerators and industrial waste incinerators in the Kanto region. The contributions of dioxin-like PCBs in Yokohama, Tsukuba, and Tanzawa depositions were less than 10% of the total TEQ; however, in Tokyo it was almost equal to or more than 50%.  相似文献   

16.
Abstract

This study characterized the emissions of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) from the stack flue gases of 17 industrial sources, which were classified into 10 categories. The results show that the mean PCDD/PCDF concentration of secondary zinc smelter (Zn-S) and secondary copper smelter (Cu-S) is 2.44 ng international toxic equivalent (I-TEQ)/Nm3 (N represents normal conditions at 0 °C, 760 mmHg), which was found to be significantly greater than that of industrial waste incinerators (mean concentration = 0.15 ng I-TEQ/Nm3). These results imply that the controlling of secondary metallurgical melting processes is more important than industrial waste incineration for the reduction of PCDD/PCDF emissions. The mean emission factors of cement production, Zn-S and Cu-S, are 0.052, 1.99, and 1.73 μg I-TEQ/t product, respectively. For industrial waste incineration, the mean emission factors of waste rubber, waste liquor, waste sludge, industrial waste solid (IWI)-1, IWI-2, IWI-3, and IWI-4 are 0.752, 0.435, 0.760, 6.64, 1.67, 2.38, and 0.094 μg I-TEQ/t feed, respectively. Most of the PCDD/PCDF emission factors established in this study are less than those reported in previous studies, which could be because of the more stringent regulations for PCDD/PCDF emissions in recent years.  相似文献   

17.
Human breast milk offers the optimal nutrition for all infants and have been widely used in biomonitoring programs to assess human exposure to lipophylic environmental contaminants such as polychlorinated dibenzo-p-dioxins (PCDD), polychlorinated dibenzofurans (PCDF) and polychlorinated biphenyls (PCB). There are no previous reports from Turkey on chemically determined levels of PCDDs, PCDFs, and PCBs in human breast milk expressed as World Health Organization (WHO) toxic equivalents (TEQ). To get an overview of the levels of these contaminants in Turkish human milk, samples from 51 Turkish women living in the Ankara, İstanbul, Antalya, Kahramanmaraş, and Afyon provinces were analyzed by high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS) throughout 2007. The mean concentrations of WHOPCDD/F-TEQ and WHOPCB-TEQ of all samples from the five regions were 7.5 and 3.1 pg g−1 on a lipid basis, respectively. PCDD/F concentrations ranged between 0.78 and 29.3 pg WHO-TEQ g−1 fat (1.7 and 36.2 pg WHO-TEQ g−1 fat, respectively, including PCB). Of the five studied locations, the lowest levels of ∑TEQs (PCDD/F + PCB) were found in the Afyon (6.8 pg WHO-TEQ g−1 fat) and the highest in the Antalya (15.6 pg WHO-TEQ g−1 fat) province. The results have been discussed in terms of regions and PCDD/F and PCBs for which analyses had been made. The mean levels of PCDD/Fs and PCBs in Turkish human milk are comparable to that found in other countries.  相似文献   

18.
Chicken eggs from five different production types (conventional, omega-3 enriched, free range, organic and free run) were collected, when available, from three regions (west, central and east) of Canada to determine persistent organic pollutant (POP) concentrations. Total polychlorinated biphenyl (PCB) concentrations (∑37 congeners) in yolks from the eggs ranged from 0.162 ng g−1 lipid to 24.8 ng g−1 lipid (median 1.25 ng g−1 lipid) while the concentration of the sum of the 6 indicator PCBs ranged from 0.100 ng g−1 lipid to 9.33 ng g−1 lipid (median 0.495 ng g−1 lipid). Total polychlorinated dibenzo-p-dioxin/dibenzofuran (PCDD/F) concentrations ranged from 2.37 pg g−1 lipid to 382 pg g−1 lipid (median 9.53 pg g−1 lipid). The 2005 WHO toxic equivalency (TEQ) ranged from 0.089 pg TEQPCDD/F+dioxin-like[DL]-PCB g−1 lipid to 12.8 pg TEQPCDD/F+DL-PCB g−1 lipid (median 0.342 pg TEQPCDD/F+DL-PCB g−1 lipid). PCB and PCDD/F concentrations were significantly different (p < 0.001) in egg yolks from different regions of collection. In contrast to observations in Europe, PCB and PCDD/F concentrations in Canadian egg yolks were not impacted solely by the production type (e.g., conventional, free range, organic, etc.) used to maintain the laying chickens. Additionally, only one Canadian free range yolk from western Canada (12.8 pg TEQPCDD/F+DL-PCB g−1 lipid) exceeded the European toxic equivalent concentration limits for eggs (5 pg TEQPCDD/F+DL-PCB g−1 lipid). This differs from observations in Europe where free range/home produced eggs frequently have higher POP concentrations than eggs from other production types. Median PCB dietary intake estimates based on consumption of eggs were less than 10 ng d−1 while median PCDD/F intakes were less than 45 pg d−1.  相似文献   

19.
Thirty-one samples of baked-salt products used in commercial food additives were analyzed for the presence of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs). Dioxins were highly detected in 12 samples of baked salts. The amount of dioxins found in the samples ranged from 12.47 pg/g to 406.56 pg/g (0.71 pg TEQ/g to 23.51 pg TEQ/g, respectively). The most abundant congeners, as TEQ values, were 2,3,4,7,8-PeCDF; 1,2,3,7,8-PeCDF; and 1,2,3,4,7,8-HxCDF in PCDF congeners and 1,2,3,7,8-PeCDD; 1,2,3,6,7,8-HxCDD; and 1,2,3,7,8,9-HxCDD in PCDD congeners. Meanwhile, PCDDs/PCDFs were analyzed in high-temperature-treated samples of natural sea salt alone and natural sea salt to which di-(2-ethylhexyl)phthalate (DEHP) had been added. In the former case, PCDD/PCDF formation was most evident at temperatures near 450 degrees C, the total amount of dioxins was 90.07 pg/g (6.07 pg TEQ/g), and PCDD congeners comprised less than 50% of the total PCDDs/PCDFs. However, when the latter samples were heated, the total PCDD/PCDF concentration was 512.30 pg/g (21.53 pg TEQ/g), with PCDD congeners comprising over 87% of the total PCDDs/PCDFs.  相似文献   

20.
Exhaust emissions of seventeen 2,3,7,8-substituted polychlorinated dibenzo-p-dioxin/furan (PCDD/F) congeners, tetra-octa PCDD/F homologues, 12 WHO 2005 polychlorinated biphenyl (PCB) congeners, mono-nona chlorinated biphenyl homologues, and 19 polycyclic aromatic hydrocarbons (PAHs) from three legacy diesel engines were investigated. The three engines tested were a 1985 model year GM 6.2 J-series engine, a 1987 model year Detroit Diesel Corporation 6V92 engine, and a 1993 model year Cummins L10 engine. Results were compared to United States’ mobile source inventory for on-road diesel engines, as well as historic and modern diesel engine emission values. The test fuel contained chlorine at 9.8 ppm which is 1.5 orders of magnitude above what is found in current diesel fuel and 3900 ppm sulfur to simulate fuels that would have been available when these engines were produced. Results indicate PCDD/F emissions of 13.1, 7.1, and 13.6 pg International Toxic Equivalency (I-TEQ) L−1 fuel consumed for the three engines respectively, where non-detects are equal to zero. This compares with a United States’ mobile source on-road diesel engine inventory value of 946 pg I-TEQ L−1 fuel consumed and 1.28 pg I-TEQ L−1 fuel consumed for modern engines equipped with a catalyzed diesel particle filter and urea selective catalytic reduction. PCB emissions are 2 orders of magnitude greater than modern diesel engines. PAH results are representative of engines from this era based on historical values and are 3-4 orders of magnitude greater than modern diesel engines.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号