首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 769 毫秒
1.
This paper focuses on investigating the current--voltage (I--V) and power--voltage (P--V) characteristics of a photovoltaic (PV) module connected in various configurations like series, parallel, and series-parallel. The performance analysis of PV module has been carried out under uniform and non-uniform conditions such as change in irradiation (passing clouds), change in temperature, accumulation of dust, and change in wind speed using MATLAB-Simulink environment. From the observed results, it has been indicated that for a given number of PV modules, the array configurations affect the maximum available output power and more local maxima are found under partially shaded conditions. Moreover, the comparative analysis of PV module has been performed for various configurations under the above disturbances. From the results, it is evident that even under non-uniform conditions, the parallel configuration of PV modules is more prominent and maximum output power is obtained. Further, parallel layout is particularly convenient for minimizing shadowing effects. The parameters of the PV module have been obtained from the manufacturer datasheet (KC200GT) for these investigations.  相似文献   

2.
Outdoor power performance measurements of silicon (Si) solar cells and its assembled module were carried out at the coastal site of geographical location of 12.0107° Latitude and 79.856° Longitude, of Puducherry, India. Measurements were analyzed in comparison with the daily solar illumination data obtained by an optical pyranometer deployed with global measurement condition. It was found that the module required ~3 times more illumination to stabilize in its output voltage than the requirement of an individual cell and exhibited 11.35% loss in its efficiency compared to its STC value. Proposed operation of 5.30 hours was found resulting in an output rating fixed at ~40% from its 100% full capacity.  相似文献   

3.
The module performance is an important consideration for selecting PV technologies for electricity production, as well as the economic aspect. Also, PV energy yield under varying environmental conditions is largely dependent on the type of technology used. Therefore, this article presents a comparative analysis of different PV modules, of the same power, namely, monocrystalline, polycrystalline, amorphous silicon and hybrid, based on performance, cost and space requirement. The performance is evaluated in terms of module power output, yield, capture losses, fill factor and efficiency, according to the IEC 61724 standards, using Gwako, Nigeria as a case study. A novel technique called Fundamental PV Module Performance Analysis is used to analyze and compare the performance of the PV modules. The performance of a single module is then employed to calculate the overall performance of a PV array designed for a small off-grid house, and a suitable module is determined amongst the modules under study. Results provide insights into the behaviors of the different technologies with the environmental factors of the location, which have an impact on their power and kWh/kW outputs and the efficiency. This knowledge, coupled with the understanding of the constraints of cost and the module space requirements would be useful to researchers, engineers, installers etc. in Nigeria, for planning and developing photovoltaic electric systems for off-grid applications.  相似文献   

4.
A contactless transformer coupling (CTC) transmission system transmits electric energy via an alternating magnetic field through an air-gap. The transmitted power can be enhanced by the application of resonant effects. Transmitting and receiving coils are usually single layer solenoids with series capacitors, which, in combination, allow the receiving element to be tuned to the required transmitter frequency. An input DC source is used to obtain high-frequency AC signal through the standardized half-bridge DC/AC switching circuit. Further, the high-frequency signal passes through matching transformer and contactless coupling induction coil, which can be considered as an isolated input and output stage. Coupling must be tight to achieve high efficiency. This paper then applies the methods of Taguchi parameter design forthe contactless transformer coupling transmission system, which enhances the output voltage, loss factor, and output efficiency of the transmission system. The results of measurement verify the feasibility of this structure in the experiment.  相似文献   

5.
ABSTRACT

According to the structure of photovoltaic/phase change material (PV/PCM), the mechanism of internal heat transfer, transmission, storage, and temperature control is analyzed, and a two-dimensional finite element analysis model of PV/PCM structure is established. This study is carried out on the effect of PCM thermal conductivity on internal temperature distribution characteristics of PV/PCM and temperature control characteristics of solar cells. The results show that the increase in thermal conductivity of PCM can prolong the temperature control time of solar cell in PV/PCM system, for example, when the thermal conductivity is increased from 0.2 W/(m·K) to1.5 W/(m·K) under a thickness of 4 cm, the duration when PV/PCM solar cell temperature is controlled below 40°C and extended from 52 min to 184 min. In addition, PV/PCM experimental prototypes are designed with the LA-SA-EG composite PCM peak melting point of 46°C and thermal conductivity of 0.8 W/(m·K) and 1.1 W/(m·K), respectively. The results indicate that compared with PCM-free solar cells, the maximum temperature of PV/PCM prototype solar cells with thermal conductivity of 0.8 W/(m·K) and 1.1 W/(m·K) is reduced by 10.8°C and 4.6°C, respectively, with average output power increased by 4.1% and 2.2%, respectively, under simulated light sources. Under natural light conditions, the average output power is increased by 6.9% and 4.3%, respectively. The results provide theoretical and experimental basis for the optimization of PV/PCM design by changing the thermal conductivity of PCM.  相似文献   

6.
Conventional solar photovoltaic (PV) module converts the light component of solar radiation into electrical power, and heat part is absorbed by module increasing its operating temperature. Combined PV module and heat exchanger generating both electrical and thermal powers is called as hybrid photovoltaic/thermal (PV/T) solar system. The paper presents the design of a PV/T collector, made with thin film PV technology and a spiral flow absorber, and a simulation model, developed through the system of several mathematical equations, to evaluate the performance of PV/T water collectors. The effect of various parameters on the thermal and electrical efficiency has been investigated to obtain optimum combination of parameters. Finally, a numerical simulation has been carried out for the daily and annual yield of the proposed PV/T collector, and comparison with a standard PV module is discussed.  相似文献   

7.
This article presents a two-stage maximum power point tracking (MPPT) controller using artificial neural network (ANN) for photovoltaic (PV) standalone system, under varying weather conditions of solar irradiation and module temperature. At the first-stage, the ANN algorithm locates the maximum power point (MPP) associated to solar irradiation and module temperature. Then, a simple controller at the second-step, by changing the duty cycle of a DC–DC boost converter, tracks the MPP. In this method, in addition to experimental data collection for training the ANN, a circuit is designed in MATLAB-Simulink to acquire data for whole ranges of weather condition. The whole system is simulated in Simulink. Simulation results show small transient response time, and low power oscillation in steady-state. Furthermore, dynamic response verifies that this method is very fast and precise at tracking the MPP under rapidly changing irradiation, and has very low power oscillation under slowly changing irradiation. Experimental results are provided to verify the simulation results as well.  相似文献   

8.
Daily global solar radiation on a horizontal surface and duration of sunshine hours have been determined experimentally for five meteorological stations in Saudi Arabia, namely, Abha, Al-Ahsa, Al-Jouf, Al-Qaisumah, and Wadi Al-Dawaser sites. Five-years of data covering 1998–2002 period have been used. Suitable Angstrom models have been developed for the global solar radiation estimation as a function of the sunshine duration for each respective sites. Daily averages of monthly solar PV power outputs have been determined using the Angstrom models developed. The effect of the PV cell temperature on the PV efficiency has been considered in calculating the PV power output. The annual average PV output energy has been discussed in all five sites for small loads. The minimum and maximum monthly average values of the daily global solar radiation are found to be 12.09 MJ/m2/d and 30.42 MJ/m2/d for Al-Qaisumah and Al-Jouf in the months of December June, respectively. Minimum monthly average sunshine hours of 5.89 hr were observed in Al-Qaisumah in December while a maximum of 12.92 hr in Al-Jouf in the month of June. Shortest range of sunshine hours of 7.33–10.12 hr was recorded at Abha station. Minimum monthly average Solar PV power of 1.59 MJ/m2/day was obtained at Al-Qaisumah in the month of December and a maximum of 3.39 MJ/m2/day at Al-Jouf in June. The annual PV energy output was found to be 276.04 kWh/m2, 257.36 kWh/m2, 256.75 kWh/m2, 245.44 kWh/m2, and 270.95 kWh/m2 at Abha, Al-Ahsa, Al-Jouf, Al-Qaisumah, and Wadi Al-Dawaser stations, respectively. It is found that the Abha site yields the highest solar PV energy among the five sites considered.  相似文献   

9.
The effect of air mass (AM) on the performance of multi-crystalline silicon (m-Si), amorphous silicon (a-Si), and hetero-junction with intrinsic thin layer (HIT)-technology-based photovoltaic (PV) modules are evaluated for representative day of four seasons during the year 2011 for composite climate of India. To find the best performing PV module technology with respect to AM at the site, annual energy yields and performance ratio against different AM bands (AM 1–4.5) are plotted. It is found that HIT modules perform better than m-Si and a-Si at each AM band. Annual energy yields for all three technologies decrease with increasing order of AM bands. The performance ratio for HIT and m-SI modules initially increases and then decreases with increasing order of AM bands. However, for a-Si modules, the performance ratio decreases with increasing order of the AM bands.  相似文献   

10.
This study designs and applies a new energy-conservation type solar-powered lighting system using a high-pressure sodium lamp to areas not having any utility company's electricity. The proposed system uses a zero-voltage-switching (ZVS) DC/DC converter in the batteries’ charge circuit to reduce the switching loss for a higher charging efficiency. Said system also adopts the maximum power point tracking (MPPT) technique to maximize the solar panels’ photovoltaic conversion capability. When dark, the batteries in the proposed system will discharge, with a raised voltage, through a push-pull DC/DC converter; said voltage, as the input voltage of the series-parallel resonant inverter, will be regulated to dim the lamp. To enable the efficient usage of the batteries’ stored energy capacity, this control scheme of the proposed system may adjust the night-time discharge time lengths, according to season difference, and compute the usable capacity for the load, according to the batteries’ charged voltage, so as to select a suitable pre-scheduled light-dimming curve for the lamp to achieve energy conservation for the batteries and continuity in lighting when dark.  相似文献   

11.
ABSTRACT

The uncertainty in the output power of the photovoltaic (PV) power generation station due to variation in meteorological parameters is of serious concern. An accurate output power prediction of a PV system helps in better design and planning. The present study is carried out for the prediction of output power of PV generating station by using Support Vector Machines. Two cases are considered in the present study for prediction. Case-I deals with the prediction of PV module parameters such as Voc, Ish, Rs, Rsh, Imax, Vmax, Pmax, and case-II deals with the prediction of power generation parameters such as PDC, PAC, and system efficiency. Historical data of PV power station with an installed capacity of 10 MW and weather information are used as input to develop four different seasons-based SVM models for all parameters. The performance results of the models are presented in terms of Mean Relative Error (MRE) and Root Mean Square Error (RMSE). Additionally, the performance results obtained with polynomial and Radial Based Function kernel are also compared to show that which kernel has better prediction accuracy, and practicability. The result shows that the minimum average RMSE and MRE for case-I with Radial Based Function kernel are 0.034%, 0.055%, 0.002%, 1.726%, 0.044%, 0.047%, 2.342%, and 0.005%, 0.014%, 0.079%, 0.885%, 0.005%, 0.007%, 0.013%, and for case-II with poly kernel are 0.014%, 0.016%, 0.149% and 0.011%, 0.0175, 1.03%, respectively. The present study will be helpful to provide technical guidance to the prediction of the PV power System.  相似文献   

12.
太阳能光伏发电成本及展望   总被引:1,自引:0,他引:1  
针对太阳能电池的昂贵发电成本,分析和预测了国内外的太阳能光伏产业链的现状与发展;指出研制高效率、低成本太阳能光伏发电系统将是今后的任务。  相似文献   

13.
This paper analyses actual performance of three grid-connected photovoltaic systems based on different silicon technologies, installed at the faculty of sciences of Agadir. The outdoor facilities consist of 2.04 kWp of mono crystalline (m-Si), 1.86 kWp of amorphous (μcSi/a-Si:H), and 2.04 kWp of multi crystalline (mc-Si) silicon PV systems. Datasets were collected during one entire year under real measured irradiation and ambient temperature conditions. The performance of these roof mounted PV systems was conducted on daily and monthly bases. Parameters like annual specific yield, system efficiency, and performance ratio were evaluated and found to be 1827 kWh/kWp.year, 20.9% and 80.2% for amorphous, 1863 kWh/kWp.year, 21.3% and 80.7%, for mono crystalline and 1895 kWh/kWp.year, 21.7% and 82.2% for multi crystalline.  相似文献   

14.
In this paper, an isolated ac module with pseudo dc-link and galvanic isolation is proposed for photovoltaic energy conversion. The studied grid-tie ac module can individually extract the maximum solar power from each photovoltaic panel and transfer to ac utility system. It consists of an interleaved active-clamping single-ended primary-inductive circuit (SEPIC) with a secondary voltage doubler, a full-bridge polarity selector operating under line frequency to achieve high efficiency. For the studied topology, key features such as reduced input current ripple, zero-voltage switching (ZVS) of primary switches, low reverse-recovery current of the output diodes, and lower switch voltage stress are obtained. Also, to reduce input current ripple, an interleaved control strategy is adopted. A simple control strategy is proposed to generate a rectified sinusoidal waveform voltage at the pseudo dc-link capacitors and achieve the high maximum power point tracking (MPPT) accuracy. The operation principles and design considerations of the studied ac module are analyzed and discussed. A prototype with 25–60 V dc input, 110 V/60 Hz ac output and 150 W power rating has been constructed for verifying the feasibility of the proposed ac module.  相似文献   

15.
高鹏 《四川环境》2014,(3):54-60
通过对220kV及110kV户内布置、户外布置方式的变电站,架空输电线路以及地下电缆线的工频电场强度、工频磁场强度的监测,分析比较了变电站及输电线路对环境的贡献水平以及衰减规律。结果表明输变电设施对环境的贡献值非常有限,且随与之距离的增加而明显衰减。  相似文献   

16.
随着电网规模的不断扩大,220 k V电压等级的输变电网络将越来越多地介入人们的日常生活,如何对民众关心的220 k V输变电工程进行客观的环境影响评价分析成为越来越重要的实际问题。以某拟建220 k V输变电工程环境影响评价为例,介绍了评价因子尤其是电磁环境的现状监测、类比监测及模式预测综合分析,深入分析了该拟建输变电工程环境影响评价全过程,对输变电工程环境影响评价工作具有一定的指导意义。  相似文献   

17.
MgO nanocrystals were synthesized and doped with different concentrations in poly(methylmethacrylate) (PMMA) to prepare hybrid organic-inorganic coatings based on polymer nanohybrid thin films. The nanoparticles were found to be spherical with 62 nm diameter as determined by X-ray diffraction (XRD) and atomic force microscope (AFM). The coatings were characterized by spectroscopic tools such as optical absorption, transmission and fluorescence spectroscopy. The prepared nanohybrid films were spin-coated on cost-effective luminescent PMMA substrates doped with highly efficient luminescent dyes luminescent solar concentrators (LSCs). The outdoor photostability tests demonstrated enhanced protection against UVA radiation for coated LSCs compared to bare LSC substrates. The current–voltage characteristics of commercially produced LSC prototypes showed that the poor UV response of monocrystalline silicon solar cell can be improved by for LSCs coated by PMMA/MgO nanohybrid films which act as luminescent down shifting layer (LDSL).  相似文献   

18.
Amorphous silicon (a-Si:H)-based solar cells have the lowest ecological impact of photovoltaic (PV) materials. In order to continue to improve the environmental performance of PV manufacturing using proposed industrial symbiosis techniques, this paper performs a life cycle analysis (LCA) on both conventional 1-GW scaled a-Si:H-based single junction and a-Si:H/microcrystalline-Si:H tandem cell solar PV manufacturing plants and such plants coupled to silane recycling plants. Both the energy consumed and greenhouse gas emissions are tracked in the LCA, then silane gas is reused in the manufacturing process rather than standard waste combustion. Using a recycling process that results in a silane loss of only 17% instead of conventional processing that loses 85% silane, results in an energy savings of 81,700 GJ and prevents 4400 tons of CO2 from being released into the atmosphere per year for the single junction plant. Due to the increased use of silane for the relatively thick microcrystalline-Si:H layers in the tandem junction plants, the savings are even more substantial – 290,000 GJ of energy savings and 15.6 million kg of CO2 eq. emission reductions per year. This recycling process reduces the cost of raw silane by 68%, or approximately $22.6 million per year for a 1-GW a-Si:H-based PV production facility and over $79 million per year for tandem manufacturing. The results are discussed and conclusions are drawn about the technical feasibility and environmental benefits of silane recycling in an eco-industrial park centered around a-Si:H-based PV manufacturing plants.  相似文献   

19.
风能作为一种清洁无污染的可再生能源,已经被广泛运用到电力事业的发展中来。近年来,新疆的风力发电发展迅速,风电场建设过程中不可避免地会对土壤及植被造成一定的破坏,人为地加剧了水土流失。概述了风电项目水土流失特点,以新疆华电小草湖风电场工程为例,结合项目区具体特点,分区设置防治措施。通过工程措施、植物措施与临时措施的有机结合,有效地防止水土流失。  相似文献   

20.
This work deals with the application of a Life Cycle Assessment approach for evaluating the environmental and energy impacts ascribed to the production of photovoltaic (PV) cells of first and second generations. PV technologies based on silicon and CuInSe2 (CIS) thin films were taken into account herein. PV systems prepared with amorphous silicon (a-Si) showed a low environmental impact and short energy payback time when compared to those ones obtained using crystalline silicon (c-Si). PV technologies associated with mono-crystal (mono-Si) and polycrystalline silicon (multi-Si) showed large emissions of CO2, nitrogen oxides, non-methane volatile organic compounds, particulates, and SO2 into air per square meter of PV panel processed. In addition, these technologies displayed a significant fossil fuel demand, biological oxygen demand, and global warming potential, which make them eco-unfriendly. Ribbon silicon (ribbon-Si) and CIS thin films showed intermediate impact scores, but further improvements in their production chain are needed before these devices are commercially used. The technologies examined herein were categorized in first- and second-generation technologies in order to compare their environmental impact and conversion efficiency. Much attention was also paid to the development of third-generation PV cells with improved conversion efficiencies and lower environmental impacts.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号