首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The aim of the study was to determine the relationship between airborne bacterial concentrations and particle counts measured simultaneously at different sites. Andersen single stage viable particle samplers were used for microbial measurements while a Laser particle counter gave the cumulated counts of particles larger than 0.5 μm diameter. The first phase of the study was performed in two experimental rooms where the basic level of microbial contamination was low. Peaks of concentrations were generated by human activity and both bacterial and particle counts were monitored over 1 h. In the second phase, measurements were run for several days in three different buildings normally occupied. Natural variations of bacterial and particle counts were monitored: microbial measurements were performed each hour while particle counts were started with a 10 min frequency. Statistics revealed strong positive correlations between bacterial and particle counts in four sites out of five. Analyses of covariance used to compare the regression lines obtained in each area showed that except for two natural sites, the regression lines were significantly different, indicating that no absolute relationship can be established between the two parameters. Therefore, particle counting should, of course, not take the place of microorganism measurements, but combining particle counting with bioaerosols measurements may allow detection of rapid variations instantaneously and indicate further microbial measurements. This strategy should improve the assessment of people“s real exposure to airborne microorganisms.  相似文献   

2.
Reliable estimates of heavy-truck volumes in the United States are important in a number of transportation applications including pavement design and management, traffic safety, and traffic operations. Additionally, because heavy vehicles emit pollutants at much higher rates than passenger vehicles, reliable volume estimates are critical to computing accurate inventories of on-road emissions. Accurate baseline inventories are also necessary to forecast future scenarios. The research presented in this paper evaluated three different methods commonly used by transportation agencies to estimate annual average daily traffic (AADT), which is used to determine vehicle miles traveled (VMT). Traffic data from continuous count stations provided by the Iowa Department of Transportation were used to estimate AADT for single-unit and multiunit trucks for rural freeways and rural primary highways using the three methods. The first method developed general expansion factors, which apply to all vehicles. AADT, representing all vehicles, was estimated for short-term counts and was multiplied by statewide average truck volumes for the corresponding roadway type to obtain AADT for each truck category. The second method also developed general expansion factors and AADT estimates. Truck AADT for the second method was calculated by multiplying the general AADT by truck volumes from the short-term counts. The third method developed expansion factors specific to each truck group. AADT estimates for each truck group were estimated from short-term counts using corresponding expansion factors. Accuracy of the three methods was determined by comparing actual AADT from count station data to estimates from the three methods. Accuracy of the three methods was compared using n-fold cross-validation. Mean squared error of prediction was used to estimate the difference between estimated and actual AADT. Prediction error was lowest for the method that developed separate expansion factors for trucks. Implications for emissions estimation using the different methods are also discussed.  相似文献   

3.
A portable, battery-operated, electro-optical dust analyzer operating on the principle of light scattering from individual dust particles in air drawn through a high-intensity light field has been developed for monitoring dust levels where external power may be unavailable. The instrument counts and size-discriminates airborne particles over two size ranges upwards of 0.3 microns with immediate readout. A dilution mechanism permits analysis of particulate concentrations as high as 2400 particles/cm3 on each channel. The self-contained Ni-Cd batteries are rechargeable. Total weight, including batteries and all components, is approximately 14 Ib. Total power used, mainly for pumping a filtered air sheath at 300 cm/sec and for the light source, is less than 34 watts. Another unique feature is the flow system designed for turbulence suppression.

Electronic calibration in terms of number of particles/cm3 for each size range is accomplished in the laboratory by means of a pulse generator with respect to which the readout indicator is calibrated for count. The input voltages to the pulse-height discriminators are appropriately attenuated for various pulse amplitudes simulating the output of the light-sensitive pickup, a photomultiplier tube.Pulse height as a function of particle size was measured for polystyrene latex beads ranging from 0.3 to 2 microns in diameter. Good correlation is obtained with results from commercial analyzers.

Field surveys have been undertaken with the CAES prototype analyzer at various sites in central Pennsylvania and at numerous sampling points within the cities of Pittsburgh and Philadelphia. Particulate concentrations as high as 1400 particles/ cm3 have been measured at a coal cleaning plant.  相似文献   

4.
Abstract

Reliable estimates of heavy-truck volumes in the United States are important in a number of transportation applications including pavement design and management, traffic safety, and traffic operations. Additionally, because heavy vehicles emit pollutants at much higher rates than passenger vehicles, reliable volume estimates are critical to computing accurate inventories of on-road emissions. Accurate baseline inventories are also necessary to forecast future scenarios. The research presented in this paper evaluated three different methods commonly used by transportation agencies to estimate annual average daily traffic (AADT), which is used to determine vehicle miles traveled (VMT). Traffic data from continuous count stations provided by the Iowa Department of Transportation were used to estimate AADT for single-unit and multiunit trucks for rural freeways and rural primary highways using the three methods. The first method developed general expansion factors, which apply to all vehicles. AADT, representing all vehicles, was estimated for short-term counts and was multiplied by statewide average truck volumes for the corresponding roadway type to obtain AADT for each truck category. The second method also developed general expansion factors and AADT estimates. Truck AADT for the second method was calculated by multiplying the general AADT by truck volumes from the short-term counts. The third method developed expansion factors specific to each truck group. AADT estimates for each truck group were estimated from short-term counts using corresponding expansion factors. Accuracy of the three methods was determined by comparing actual AADT from count station data to estimates from the three methods. Accuracy of the three methods was compared using n-fold cross-validation. Mean squared error of prediction was used to estimate the difference between estimated and actual AADT. Prediction error was lowest for the method that developed separate expansion factors for trucks. Implications for emissions estimation using the different methods are also discussed.  相似文献   

5.
The prototype charged fog generator described in a preceding paper1 was field tested on a fugitive emission source at a bentonite ore processing plant in Worland, Wyoming, during 1981. Participate matter samples were collected as fine and coarse fractions under three different test scenarios: with no control, with partial control (uncharged fog), and with full control (charged fog). Measured particulate matter sample concentrations were normalized for each test day with respect to the background values so that particle control efficiency of the device could be evaluated without any bias during the entire test program.

These tests have shown that mean value of the inhalable particle control efficiency of charged fog measured under all instrument settings and field conditions is increased by 78% when compared with uncharged fog. In particular, fine particle control efficiencies of over 90% were recorded under optimum instrument settings and ideal field conditions. The bentonite particles seemed to carry a net positive charge. The optimum instrument settings were found to be: 60 L/h water flow rate, an applied voltage of 10-15 kV and a spray pattern which covers maximum volume of dust-laden air. Ideal field conditions are high relative humidity and calm or low winds.

Charged fog technology appears to be an effective and economically feasible method to control sources of fugitive particle emission in the inhalable size range. Further research is needed to evaluate the inhalable particle control efficiency of the device for emissions of various chemical compositions.  相似文献   

6.
The body of information presented in this paper is directed to those individuals concerned with the measurement of the size distribution of particulate matter in air. The light scattering instrument described herein is characterized by the fact that it can accurately size particles almost independently of their index of refraction. The basic concept involves the simultaneous measurement of the intensity of light scattered by a single particle at two small scattering angles. The ratio of the two intensities is directly related io ine size of ihe pariicle, and for scattering angles of 5° and 10° the effective range of the instrument is 0.2 to 4 μm. The air flows through the optical system at such a rate that approximately 25 μs are required to determine the size of each particle, and concentrations as high as 104 particles/cc can be measured without dilution and without serious coincidence effects. By employing a multichannel analyzer as the data storage and readout device it is possible to detect changes in particulate size distribution within a few seconds. Calibration of the instrument has been performed using polystyrene latex spheres and materials having a wide range of index of refraction and shape including carbon black, iron oxide and spores.  相似文献   

7.
The conceptual design and evaluation of a fine particle sizing and counting instrument are introduced in this paper. A corresponding laboratory prototype was developed by coupling aerodynamic particle focusing with corona charging techniques that could detect particle sizes down to 25 nm in diameter. Comparison between the prototype and a condensation particle counter (CPC) using identical monodisperse particles showed that the measurements agreed well for the particle sizes in the range of 60–300 nm.  相似文献   

8.
A recently developed photometer utilizes near-forward scattered light to count and size aerosol particles in the diameter range 0.3-17 μ. The particles are drawn through a 1-cu mm illuminated volume without entering the body of the optical chamber. Hence, purging is almost instantaneous, and number concentrations below 1,000,000/cu ft give less than 3% coincidences. The scattered light pulse from each particle is detected by a photomultiplier tube. The resultant voltage pulses are amplified, measured by a series of ten discriminator circuits, and stored in a series of ten 5-decade electronic counters. At the end of a chosen period ranging from 1/3 to 30 min, a digital printer prints the number of particles at each diameter. At the end of the printout, the procedure automatically recycles. The instrument provides ten size classifications, each successively having a width ratio of 1.5 to 1. Greater precision is seldom practical since most aerosols contain particles of different refractive index, color, and shape, all of which affect the intensity of the scattered light. Calibration is accomplished with aerosols of uniform size such as spray-dried polystyrene and other latex suspensions, supplemented by calculations based on the Mie theory of light scattering.  相似文献   

9.
Reactions between ozone and terpenes have been shown to increase the concentrations of submicron particles in indoor settings. The present study was designed to examine the influence of air exchange rates on the concentrations of these secondary organic aerosols as well as on the evolution of their particle size distributions. The experiments were performed in a manipulated office setting containing a constant source of d-limonene and an ozone generator that was remotely turned “on” or “off” at 6 h intervals. The particle number concentrations were monitored using an optical particle counter with eight-channels ranging from 0.1–0.2 to>2.0 μm diameter. The air exchange rates during the experiments were either high (working hours) or low (non-working hours) and ranged from 1.6 to>12 h−1, with intermediate exchange rates. Given the emission rates of ozone and d-limonene used in these studies, at an air exchange rate of 1.6 h−1 particle number concentration in the 0.1–0.2 μm size-range peaked 1.2 h after the ozone generator was switched on. In the ensuing 4.8 h particle counts increased in successive size-ranges up to the 0.5–0.7 μm diameter range. At higher air exchange rates, the resulting concentrations of total particles and particle mass (calculated from particle counts) were smaller, and at exchange rates exceeding 12 h−1, no excess particle formation was detectable with the instrument used in this study. Particle size evolved through accretion and, in some cases, coagulation. There was evidence for coagulation among particles in the smallest size-range at low air exchange rates (high particle concentrations) but no evidence of coagulation was apparent at higher air exchange rates (lower particle concentrations). At higher air exchange rates the particle count or size distributions were shifted towards smaller particle diameters and less time was required to achieve the maximum concentration in each of the size-ranges where discernable particle growth occurred. These results illustrate still another way in which ventilation affects human exposures in indoor settings. However, the ultimate effects of these exposures on health and well being remain to be determined.  相似文献   

10.
As part of two separate studies aimed to characterize ambient pollutant concentrations at schools in urban areas, we compare black carbon and particle count measurements at Adcock Elementary in Las Vegas, NV (April–June 2013), and Hunter High School in the West Valley City area of greater Salt Lake City, UT (February 2012). Both schools are in urban environments, but Adcock Elementary is next to the U.S. 95 freeway. Black carbon (BC) concentrations were 13% higher at Adcock compared to Hunter, while particle count concentrations were 60% higher. When wind speeds were low—less than 2 m/sec—both BC and particle count concentrations were significantly higher at Adcock, while concentrations at Hunter did not have as strong a variation with wind speed. When wind speeds were less than 2 m/sec, emissions from the adjacent freeway greatly affected concentrations at Adcock, regardless of wind direction. At both sites, BC and particle count concentrations peaked in the morning during commute hours. At Adcock, particle count also peaked during midday or early afternoon, when BC was low and conditions were conducive to new particle formation. While this midday peak occurred at Adcock on roughly 45% of the measured days, it occurred on only about 25% of the days at Hunter, since conditions for particle formation (higher solar radiation, lower wind speeds, lower relative humidity) were more conducive at Adcock. Thus, children attending these schools are likely to be exposed to pollution peaks during school drop-off in the morning, when BC and particle count concentrations peak, and often again during lunchtime recess when particle count peaks again.

Implications: Particle count concentrations at two schools were shown to typically be independent of BC or other pollutants. At a school in close proximity to a major freeway, particle count concentrations were high during the midday and when wind speeds were low, regardless of wind direction, showing a large area of effect from roadway emissions even when the school was not downwind of the roadway. At the second school, which sits in an urban neighborhood away from freeways, high particle counts occurred even though solar radiation was low during wintertime conditions, meaning that exposure to high particle counts can occur throughout the year.  相似文献   


11.
No personal aerosol sampler has been evaluated for monitoring aeroallergens in outdoor field conditions and compared to conventional stationary aerobiological samplers. Recently developed Button Personal Inhalable Aerosol Sampler has demonstrated high sampling efficiency for non-biological particles and low sensitivity to the wind direction and velocity. The aim of the present study was to evaluate the Button Sampler for the measurement of outdoor pollen grains and fungal spores side-by-side with the widely used Rotorod Sampler. The sampling was performed for 8 months (spring, summer and fall) at a monitoring station on the roof of a two-storied office building located in the center of the city of Cincinnati. Two identical Button Samplers, one oriented towards the most prevalent wind and the other towards the opposite wind and a Rotorod Sampler were placed side-by-side. The total fungal spore concentration ranged from 129 to 12,980 spores m(-3) (number per cubic meter of air) and the total pollen concentration from 4 to 4536 pollen m(-3). The fungal spore concentrations obtained with the two Button Samplers correlated well (r = 0.95; p<0.0001). The pollen data also showed positive correlation. These findings strongly support the results of earlier studies conducted with non-biological aerosol particles, which demonstrated a low wind dependence of the performance of the Button Sampler compared to other samplers. The Button Sampler's inlet efficiency was found to be more dependent on wind direction when sampling larger sized Pinaceae pollen grains (aerodynamic diameter approximately 65 mum). Compared to Rotorod, both Button Samplers measured significantly higher total fungal spore concentrations. For total pollen count, the Button Sampler facing the prevalent wind showed concentrations levels comparable to that of the Rotorod, but the Button Sampler oriented opposite to the prevalent wind demonstrated lower concentration levels. Overall, it was concluded that the Button Sampler is efficient for the personal sampling of outdoor aeroallergens, and is especially beneficial for aeroallergens of small particle size.  相似文献   

12.
The Interagency Monitoring of Protected Visual Environments (IMPROVE) particle monitoring network consists of approximately 160 sites at which fine particulate matter (PM2.5) mass and major species concentrations and course particulate matter (PM10) mass concentrations are determined by analysis of 24-hr duration sampling conducted on a 1-day-in-3 schedule A simple algorithm to estimate light extinction from the measured species concentrations was incorporated in the 1999 Regional Haze Rule as the basis for the haze metric used to track haze trends. A revised algorithm was developed that is more consistent with the recent atmospheric aerosol literature and reduces bias for high and low light extinction extremes. The revised algorithm differs from the original algorithm in having a term for estimating sea salt light scattering from Cl(-) ion data, using 1.8 instead of 1.4 for the mean ratio of organic mass to measured organic carbon, using site-specific Rayleigh scattering based on site elevation and mean temperature, employing a split component extinction efficiency associated with large and small size mode sulfate, nitrate and organic mass species, and adding a term for nitrogen dioxide (NO2) absorption for sites with NO2 concentration information. Light scattering estimates using the original and the revised algorithms are compared with nephelometer measurements at 21 IMPROVE monitoring sites. The revised algorithm reduces the underprediction of high haze periods and the overprediction of low haze periods compared with the performance of the original algorithm. This is most apparent at the hazier monitoring sites in the eastern United States. For each site, the PM10 composition for days selected as the best 20% and the worst 20% haze condition days are nearly identical regardless of whether the basis of selection was light scattering from the original or revised algorithms, or from nephelometer-measured light scattering.  相似文献   

13.
A fluoride analyzer originally designed by Wiggins, St. John, Thomas arid associates at Stanford Research Institute, has been modified to improve its operational capabilities and reliability so as to operate for periods in excess of six months with virtually no maintenance. It measures hydrogen fluoride in the atmosphere in the sub-parts per billion range. The need for the instrument, method of measuring fluoride and the modifications made to improve the SRI instrument are presented. The instrument has been operated in the field for two years beside impingers which obtain daily integrated samples. The impingers samples are subsequently titrated. Satisfactory correlation has been found between the average daily values by the automatic analyzer and the impinger.  相似文献   

14.
ABSTRACT

Increases in large wildfire frequency and intensity and a longer fire season in the western United States are resulting in a significant increase in air pollution, including concentrations of PM2.5 (particulate matter <2.5 µm in aerodynamic diameter) that pose significant health risks to nearby communities. During wildfires, government agencies monitor PM2.5 mass concentrations providing information and actions needed to protect affected communities; this requires continuously measuring instruments. This study assessed the performance of seven candidate instruments: (1) Met One Environmental beta attenuation monitor (EBAM), (2) Met One ES model 642 (ES642), (3) Grimm Environmental Dust Monitor 164 (EDM), (4) Thermo ADR 1500 (ADR), (5) TSI DRX model 8543 (DRX), (6) Dylos 1700 (Dylos), and (7) Purple Air II (PA-II) in comparison with a BAM 1020 (BAM) reference instrument. With the exception of the EBAM, all candidates use light scattering to determine PM2.5 mass concentrations. Our comparison study included environmental chamber and field components, with two of each candidate instrument operating next to the reference instrument. The chamber component involved 6 days of comparisons for biomass combustion emissions. The field component involved operating all instruments in an air monitoring station for 39.5 days with hourly average relative humidity (RH) ranging from 19% to 98%. Goals were to assess instrument precision and accuracy and effects of RH, elemental carbon (EC), and organic carbon (OC) concentrations. All replicate candidate instruments showed high hourly correlations (R2 ≥ 0.80) and higher daily average correlations (R2 ≥ 0.90), where all instruments correlated well (R2 ≥ 0.80) with the reference. The DRX and Purple Air overestimated PM2.5 mass concentrations by a factor of ~two. Differences between candidates and reference were more pronounced at higher PM2.5 concentrations. All optical instruments were affected by high RH and by the EC/OC ratio. Equations to convert candidate instruments data to FEM BAM type data are provided to enhance the usability of data from candidate instruments.

Implications: This study tested the performance of seven candidate PM2.5 mass concentration measuring instruments in two settings - environmental chamber and field. The instruments were tested to determine their suitability for use during biomass combustion events and the effects of RH, PM mass concentrations, and concentrations of EC and OC on their performance. The accuracy and precision of each monitor and effect of RH, PM concentration, EC and OC concentrations are varied. The data show that most of these candidate instruments are suitable for measuring PM2.5 concentration during biomass combustions with a proper correction factor for each instrument type.  相似文献   

15.
Particulate mass concentration measurements have been made on environmental tobacco smoke (ETS) for the purpose of assessing the relative accuracy of several measurement procedures. ETS over a range of concentrations was generated in an environmental chamber by three methods. Mass concentration was measured by a gravimetric/spectrophotometric collection procedure, piezoelectric particle mass monitors, two nephelometry-based mass monitors, and a particle counting and sizing system. Two-hour average mass concentrations were determined by each method for concentrations ranging from very low levels up to those achieved by smoking one entire cigarette in the chamber. Statistical comparisons were made among procedures employing the gravimetric filter measurement as the basis for comparison. One nephelometry-based procedure gave significantly higher and the other significantly lower values than the filter determination. In one case, a correction for the difference between the particle mass density of the calibrating aerosol and that of ETS brought the nephelometry-based procedure into reasonable agreement with the filter measurement, while for the other, the correction did not resolve the discrepancy between methods. Statistically significant differences between the responses of two supposedly identical piezoelectric mass monitors were found, as was some slight dependence of the nephelometry- based procedures on method of ETS generation. In summary, the results indicate that significant errors can be expected if the instruments studied are used “off the shelf,” even for ETS generated under controlled laboratory conditions. Caution should be employed in field measurements where numerous sources and types of particulate matter can be encountered.  相似文献   

16.
Continuous monitors were employed for 18 months in an occupied townhouse to measure ultrafine, fine, and coarse particles; air change rates; wind speed and direction; temperature; and relative humidity (RH). A main objective was to document short-term and long-term variation in indoor air concentrations of size-resolved particles (0.01-20 microm) caused by (1) diumal and seasonal variation of outdoor air concentrations and meteorological variables, (2) indoor sources such as cooking and using candles, and (3) activities affecting air change rates such as opening windows and using fans. A second objective was to test and compare available instruments for their suitability in providing real-time estimates of particle levels and ancillary variables. Despite different measuring principles, the instruments employed in this study agreed reasonably well for particles less than 10 microm in diameter. The three instruments measuring fine and coarse particles (aerodynamic diameter between 0.3 and 20 microm) agreed to within 30% in their overall estimates of total volume. Two of these instruments employed optical scattering, and the third used an aerodynamic acceleration principle. However, several lines of evidence indicated that the instrument employing aerodynamic acceleration overestimated concentrations for particle diameters greater than 10 microm. A fourth instrument measuring ultrafine and accumulation-mode particles (0.01-1 microm) was operated with two different inlets providing somewhat different particle size ranges. The two inlets agreed in the ultrafine region (< 0.1 microm) but diverged increasingly for larger particles (up to 0.445 microm). Indoor sources affecting ultrafine particle concentrations were observed 22% of the time, and sources affecting fine and coarse particle concentrations were observed 12 and 15% of the time, respectively. When an indoor source was operating, particle concentrations for different sizes ranged from 2 to 20 times the average concentrations when no indoor source was apparent. Indoor sources, such as cooking with natural gas, and simple physical activities, such as walking, accounted for a majority (50-90%) of the ultrafine and coarse particle concentrations, whereas outdoor sources were more important for accumulation-mode particles between 0.1 and 1 microm in diameter. Averaged for the entire year and including no periods when indoor sources were apparent, the number distribution was bimodal, with a peak at approximately 10 nm (possibly smaller), a shallow minimum at approximately 14 nm, and a second broad peak at approximately 68 nm. The volume distribution was also bimodal, with a broad peak at approximately 200 nm, a minimum at approximately 1.2 microm, and then an upward slope again through the remaining size fractions. A database was created on a 5-min averaging time basis. It contains more than 90,000 measurements by two of the instruments and approximately 30,000 by the two optical scattering instruments. About 4500 hour-long average air change rates were also calculated throughout the year using a dedicated gas chromatograph with electron capture detection (GC/ECD). At high air change rates [> 0.8 air changes per hour (hr(-1))], particle concentrations were either elevated (when no source was present) or depressed (when an indoor source was operating) by factors of up to 2 compared with low air change rates.  相似文献   

17.
With a specially designed generator, producing an aerosol of concentration, chemical composition, and size distribution similar to incinerator aerosols, a scrubber was tested in the laboratory by sampling before and after the collector. Using an Andersen Sampler as a 7 stage cascade impactor the efficiency for 7 different size classes was determined. This technique provides a rapid and simple method for evaluating the performance of a collector as a function of particle size. The multistage impaction classifies the particles according to their aerodynamic behavior. Gravimetric analysis of each stage eliminates the need for tedious counting and sizing.  相似文献   

18.
Ostrya spp. and Carpinus spp. pollen was in vitro exposed to three atmospheric pollutants: CO, O3 and SO2. Two levels of each pollutant were used, and the first level corresponds to a concentration about the atmospheric hour-limit value acceptable for human health protection in Europe and the second level to about the triple of the first level. Experiments were done under artificial solar light with temperature and relative humidity controlled. The viability of the exposed pollen samples showed a significant decrease. Also, the germination percentage showed a significant decrease in both exposed pollens, and the effect was most pronounced for SO2, followed by O3 and CO. A general decreasing trend in the total soluble protein content of the exposed pollen samples when compared with the control was observed, but it was only statistically significant for the Ostrya spp pollen. The results showed marked effects were observed on the Ostrya spp. and Carpinus spp. pollen when exposed to air pollutant levels that can be considered safe for human health protection.  相似文献   

19.
Rapid and reliable detection of harmful algae in coastal areas and shellfish farms is an important requirement of monitoring programmes. Monitoring of toxic algae by means of traditional methods, i.e., light microscopy, can be time consuming when many samples have to be routinely analysed. Reliable species identification requires expensive equipment and trained personnel to carry out the analyses. However, all techniques for the monitoring of harmful algae usually require transportation of samples to specialised laboratories. In many monitoring laboratories, results are usually obtained within five working days after receiving the sample and therefore preventative measures are not always possible. Molecular technologies are rapidly improving the detection of phytoplankton and their toxins and the speed at which the results can be obtained. Assays are based on the discrimination of the genetic differences of the different species and species-specific probes can be designed. Such probes have been adapted to a microarray or phylochip format and assessed in several EU monitoring sites. Microarray results are presented for 1 year of field samples validated with cell counts from concentrated samples taken during toxic events from the weekly sampling of the Galician Monitoring Programme done by INTECMAR. The Galician monitoring laboratory does their own counting and their results are posted on their web site within 24 h. There was good correlation between cells present and microarray signals. In the few cases of false negatives, these can be attributed to poor RNA extraction of the target species, viz. Prorocentrum or Dinophysis. Where potential false positives were encountered, the smaller volume taken for cell counts as compared to the upto 300 times more volume taken for RNA extraction for the microarray is likely the cause for these differences, making the microarray more sensitive. The microarray was able to provide better species resolution in Alexandrium and Pseudo-nitzschia. In all cases, the toxins recovered by the toxin array were matched by target species in the array or in the cell counts.  相似文献   

20.
Abstract

Continuous monitors were employed for 18 months in an occupied townhouse to measure ultrafine, fine, and coarse particles; air change rates; wind speed and direction; temperature; and relative humidity (RH). A main objective was to document short-term and long-term variation in indoor air concentrations of size-resolved particles (0.01-20 μm) caused by (1) diurnal and seasonal variation of outdoor air concentrations and meteorological variables, (2) indoor sources such as cooking and using candles, and (3) activities affecting air change rates such as opening windows and using fans. A second objective was to test and compare available instruments for their suitability in providing real-time estimates of particle levels and ancillary variables.

Despite different measuring principles, the instruments employed in this study agreed reasonably well for particles less than 10 μm in diameter. The three instruments measuring fine and coarse particles (aerodynamic diameter between 0.3 and 20 μm) agreed to within 30% in their overall estimates of total volume. Two of these instruments employed optical scattering, and the third used an aerodynamic acceleration principle. However, several lines of evidence indicated that the instrument employing aerodynamic acceleration overestimated concentrations for particle diameters greater than 10 μm. A fourth instrument measuring ultrafine and accumulation-mode particles (0.01-1 μm) was operated with two different inlets providing somewhat different particle size ranges. The two inlets agreed in the ultrafine region (<0.1 μm) but diverged increasingly for larger particles (up to 0.445 μm).

Indoor sources affecting ultrafine particle concentrations were observed 22% of the time, and sources affecting fine and coarse particle concentrations were observed 12 and 15% of the time, respectively. When an indoor source was operating, particle concentrations for different sizes ranged from 2 to 20 times the average concentrations when no indoor source was apparent. Indoor sources, such as cooking with natural gas, and simple physical activities, such as walking, accounted for a majority (50-90%) of the ultrafine and coarse particle concentrations, whereas outdoor sources were more important for accumulation-mode particles between 0.1 and 1 um in diameter. Averaged for the entire year and including no periods when indoor sources were apparent, the number distribution was bimodal, with a peak at ~10 nm (possibly smaller), a shallow minimum at ~14 nm, and a second broad peak at ~68 nm. The volume distribution was also bimodal, with a broad peak at ~200 nm, a minimum at ~1.2 μm, and then an upward slope again through the remaining size fractions.

A database was created on a 5-min averaging time basis. It contains more than 90,000 measurements by two of the instruments and approximately 30,000 by the two optical scattering instruments. About 4500 hour-long average air change rates were also calculated throughout the year using a dedicated gas chromatograph with electron capture detection (GC/ECD). At high air change rates [>0.8 air changes per hour (hr?1)], particle concentrations were either elevated (when no source was present) or depressed (when an indoor source was operating) by factors of up to 2 compared with low air change rates.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏