首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
As a complement to traditional exposure assessment, monitoring deposition of aerosols can be a simple and quick screening method for identifying deposited aerosols. In this presentation examples of screening studies, based on wipe sampling in combination with adequate analytical techniques, are described. These screening methods are rapid, simple and easy to carry out. The examples given in this presentation show a broad applicability and the methods are proven useful for assessing aerosol distribution in the workplace as well as to identify target spots for more extensive assessment of a worker's exposure situation.  相似文献   

2.
Low flow active sampling techniques collecting vapors and gases using thermally desorbable adsorbents are now feasible and desirable in many applications as they permit long integration times, the potential for miniaturized sampling configurations, and other advantages. At very low air flow rates (< 1 ml min(-1)), diffusive uptake on adsorbents in conventional sorbent tubes may equal or exceed the active (pumped) uptake rate, and even at low flow rates (1-4 ml min(-1)), diffusive uptake may significantly bias measurements. Thus, corrections to account for the diffusive flux or means to limit the diffusive uptake are needed in low flow applications. This paper presents (1) a theoretical analysis of the role of diffusive and advective uptake for several sampling geometries of tube-type samplers; (2) experimental confirmation using both laboratory and field studies; (3) estimates of the tortuosity and porosity of the glass wool packing used to retain the adsorbent, parameters needed to estimate diffusive fluxes in passive and active sampling; (4) a demonstration that orifice-equipped low flow active samplers can reduce diffusive uptake and improve precision, and (5) a model predicting the saturated adsorbent layer that helps to account for the gradual decline in uptake rates seen in passive sampling. Diffusive uptake will depend on the tube configuration and diffusion coefficient of the substance of interest, but for conventional sampling tubes (0.4-0.5 cm id, 1.5 cm air gap), sample flow rates should be maintained above 1 to 4 ml min(-1) to keep errors below 5%. Laboratory experiments showed close agreement with theoretical calculations, and the field study using 1 to 4 d sampling periods and 0.3 ml min(-1) flows demonstrated that the orifice-equipped samplers essentially eliminated diffusive uptake. No significant practical difficulties are encountered using orifices, e.g., pressure drop is minimal. Experimental estimates of tortuosity (0.79 +/- 0.02) and porosity (0.92 +/- 0.10) of the glass wool packing (0.3 cm length) represent relatively little resistance to diffusion; however, variation in the packing and adsorbent placement can degrade the precision achievable by passive samplers. Diffusion barriers, consisting most simply of an orifice, may be used to lower the diffusive uptake. A needle-type orifice permits flows below 0.1 ml min(-1) and is suitable for sampling periods as long as several weeks, and it provided greater precision than conventional open-ended sampling tubes (8% compared to 13%). Finally, the gradual decrease in diffusive fluxes often seen in passive sampling is attributed to additional resistance posed by a saturated adsorbent layer, in agreement with a simple model based on total VOCs and specific adsorptivity of the adsorbent.  相似文献   

3.
In the last decade, the development of novel analytical methodologies enabled the identification of several environmental pollutants responsible for health problems associated with indoor exposure. Polycyclic aromatic hydrocarbons (PAHs) are among the potential hazardous chemicals present in ambient air. Due to their bioaccumulation potential and carcinogenic/mutagenic effects, 16 PAHs are currently listed as priority air pollutants. The main goal of this work was to implement a new and simple method for sampling and determination of PAHs in air by using a thermal desorption (TD) technique followed by gas chromatography coupled with mass spectrometry analysis. A detailed study was carried out to optimise the experimental method in each of its phases, including (active) sampling, TD and chromatographic analysis. The results demonstrate that this approach allowed the detection and quantification of the six more volatile PAHs, namely, naphthalene, acenaphthylene, acenaphthene, fluorene, phenanthrene, and anthracene. Acceptable precision and good linearity over the explored range were obtained. No carry-over was observed during experimental tests and the method provided a reproducible answer. The applicability of the novel methodology was tested in real environment, namely, on the roof of a building in an urban area, in a domestic kitchen and in a collective car garage. The method enabled the identification of two PAHs in the field samples, specifically, naphthalene (two rings) and phenanthrene (three rings). With regard to PAHs sample composition, the most abundant PAH found, in the three different locations, was naphthalene, accounting for about 84–100 % of the total PAH mass detected.  相似文献   

4.
Under international treaty, the United States and Russia are disposing of their aging stockpile of chemical weapons. Incineration and chemical neutralization are options for sites in the United States, although Russia prefers the latter. The storage and disposal of bulk and chemical agents and weapons involve unique hazards of handling extremely toxic materials. There are three major areas of concern--the storage stockpile, the disposal area, and the discovery and destruction of "found" material not considered part of the stockpile. Methods have been developed to detect the presence of chemical agents in the air, and these are used to help assure worker protection and the safety of the local population. Exposure limits for all chemical agents are low, sometimes nanograms per cubic meter for worker control limits and picograms per cubic meter for general population limits. There are three types of monitoring used in the USA: alarm, confirmation, and historical. Alarm monitors are required to give relatively immediate real-time responses to agent leaks. They are simple to operate and rugged, and provide an alarm in near real-time (generally a few minutes). Alarm monitors for the demilitarization program are based on sorbent pre-concentration followed by thermal desorption and simple gas chromatography. Alarms may need to be confirmed by another method, such as sample tubes collocated with the alarm monitor and analyzed in a laboratory by more sophisticated chromatography. Sample tubes are also used for historical perimeter monitoring, with sample periods typically of 12 h. The most common detector is the flame photometric detector, in sulfur or phosphorous mode, although others, such as mass-selective detectors, also have been used. All agents have specific problems with collection, chromatography and detection. Monitoring is not made easier by interferences from pesticide spraying, busy roadways or military firing ranges. Exposure limits drive the requirements for analytical sensitivity. Lowering limits adds additional difficulties to the monitoring efforts. The various monitoring methods and the role they play in ensuring worker and general population safety are discussed.  相似文献   

5.
Air sampling, using sorbents, thermal desorption and gas chromatography, is a versatile method for identifying and quantifying trace levels of volatile organic compounds (VOCs). Thermal desorption can provide high sensitivity, appropropriate choices of sorbents and method parameters can accommodate a wide range of compounds and high humidity, and automated short-path systems can minimize artifacts, losses and carry-over effects. This study evaluates the performance of a short-path thermal desorption method for 77 VOCs using laboratory and field tests and a dual sorbent system (Tenax GR, Carbosieve SIII). Laboratory tests showed that the method requirements for ambient air sampling were easily achieved for most compounds, e.g., using the average and standard deviation across target compounds, blank emissions were < or = 0.3 ng per sorbent tube for all target compounds except benzene, toluene and phenol; the method detection limit was 0.05 +/- 0.08 ppb, reproducibility was 12 +/- 6%, linearity, as the relative standard deviation of relative response factors, was 16 +/- 9%, desorption efficiency was 99 +/- 28%, samples stored for 1-6 weeks had recoveries of 87 +/- 9%, and high humidity samples had recoveries of 102 +/- 12%. Due to sorbent, column and detector characteristics, performance was somewhat poorer for phenol groups, ketones, and nitrogen containing compounds. The laboratory results were confirmed in an analysis of replicate samples collected in two field studies that sampled ambient air along roadways and indoor air in a large office building. Replicates collected under field conditions demonstrated good agreement except for very low concentrations or large (> 41 volume) samples of high humidity air. Overall, the method provides excellent performance and satisfactory throughput for many applications.  相似文献   

6.
Occupational exposure to inhalational anesthetics occurs routinely in operating rooms. It could induce serious health hazards and diseases. This exposure assessment is a crucial step in determining risks. In this study, a pen-shaped holder for solid-phase microextraction (SPME) sampler was successfully applied as a time-weighted average sampling tool for workshift exposure assessment of operation room staff to halothane. It proved to be very convenient for use in occupational environments such as operation rooms. Samples were analyzed by a gas chromatography-mass spectrometry. The validity of the SPME method was checked in real-world conditions with Occupational Safety and Health Administration (OSHA) 103 standard method for the determination of inhalational anesthetics. A good agreement between OSHA 103 and SPME methods was obtained and results demonstrated no statistically significant differences in anesthetic concentrations determined by the two analytical methods (p?≥?0.05). It is concluded that SPME in retracted mode could successfully be applied in occupational exposure assessment purposes.  相似文献   

7.
静态顶空进样气相色谱法测定水中CS2的研究   总被引:2,自引:0,他引:2  
采用气相色谱法静态顶空进样,极性柱分离,ECD检测器检测,对CS2的测定进行了全面的实验.实验表明,本方法简单、快速,并且具有精密度好、准确度高和检出限低的特点,完全能够满足快速分析水中CS2的要求.  相似文献   

8.
While air sampling techniques using adsorbent-based collection, thermal desorption and chromatographic analysis have found a niche in ambient air sampling, occupational applications have been more limited. This paper evaluates the use of thermal desorption techniques for low flow active and passive sampling configurations which allow conveniently long duration sampling in occupational settings and other high concentration environments. The use of an orifice enables flows as low as 0.5 ml min(-1) and sampling periods up to several days without significant biases. A model is used to predict sampling rates of a passive sampler encompassing an orifice, a void space, glass wool, and the adsorbent. Laboratory and field tests conducted at a commercial offset printing facility, which contained a variety of volatile organic compounds (primarily aromatic but also a few chlorinated and terpene compounds at levels from 1 to 67,000 microg m(-3)), are used to evaluate the approach. Tenax GR and Carbosieve SIII, both singly and together, were employed as adsorbents. Side-by-side tests comparing high flow, low flow and passive samplers show excellent agreement and high linearity (r = 0.95) for concentrations spanning nearly five orders of magnitude. Active samplers were tested at flows as low as 0.5 ml min(-1), compared to typical flows up to 40 ml min(-1). Passive samplers demonstrated a linear range and agreement with predictions for adsorbate loadings from approximately 1 ng to nearly 10 microg. Using a chemical mass balance receptor model, concentrations in the facility were apportioned to solvents, inks and other indoor and outdoor sources. Overall, the use of low flow active and passive sampling approaches employing thermal desorption techniques provides good performance and tremendous flexibility that facilitates use in many applications, including workplace settings.  相似文献   

9.
Passive sampling of glycol ethers and their acetates in indoor air   总被引:1,自引:0,他引:1  
This study examined the performances of a thermal desorbable radial diffusive sampler for the weekly measurement of eight glycol ethers in indoor air and described the results of an application of this method carried out as part of HABIT'AIR Nord - Pas de Calais program for the air monitoring of these compounds in sixty homes located in northern France. The target compounds were the four glycol ethers banned from sale to the public in France since the 1990s (i.e. 2-methoxy ethanol, 2-ethoxy ethanol and their acetates) and four other glycol ethers derivatives of which the use have increased considerably (i.e. 1-methoxy-2-propanol, 2-butoxy ethanol and their acetates).A test program was carried out with the aim of validating the passive sampling method. It allowed the estimation of all the parameters of a method for each compound (calibration, analytical precision, desorption efficiency, sampling rate in standard conditions, detection limit and stability of sample before and after exposure), the examination of the influence of environmental factors on the sampling rate by some exposure chamber experiments and the assessment of the uncertainty of the measurements.The results of this evaluation demonstrated that the method has turned out to be suitable for six out of eight glycol ethers tested. The effect of the environmental factors on the sampling rates was the main source of measurement uncertainty. The measurements done in sixty homes revealed a relative abundance of 1-methoxy-2-propanol that was found in more than two thirds of homes at concentration levels of 4.5 microg m(-3) on average (a maximum value of 28 microg m(-3)). 1-methoxy-2-propanol acetate and 2-butoxy ethanol were also detected, but less frequently (in 19% of homes) and with the concentrations below 12 microg m(-3). The highest levels of these glycol ethers appear to be in relation to the emissions occurring at the time of cleaning tasks.  相似文献   

10.
以合成的新型胆甾酯类侧链聚硅氧烷液晶高分子作固定液 ,涂渍在弹性石英毛细管柱上 ,具有较高的柱效和选择性 ,热稳定性好 ,适于分离多种异构体混合物。  相似文献   

11.
Comprehensive two dimensional gas chromatography-time-of-flight mass spectrometry (GC×GC-TOF-MS) was used for screening and semiquantitation of semivolatile organic compounds in aerosol particles. As the volatility was a prerequisite parameter for the analysis, some compounds were transformed via derivatization such as silylation into more volatile ones. The identification of the analytes was made by comparing the GC retention indices and the TOF mass spectra with the NIST and the Golm metabolome database reference libraries. The data treatment was simplified by exploiting an additional classification of the identified compounds, namely the main functional group or specific element present in the molecule leading to different groups of compounds. This methodology was applied to identify compounds in 30 ± 4 nm, 50 ± 5 nm and total suspended particles (TSP) collected during spring and autumn of 2009 and summer of 2010 at the Station for Measuring Forest Ecosystem Atmosphere Relations (SMEAR II) at Hyyti?l? (Finland). The number of identified compounds was higher than 400, which were the most relevant compounds present in the samples, in terms of concentrations. The analysis of aerosol particles of different sizes, collected simultaneously, revealed that the number of compounds increased with the particle size whereas the normalized response factor decreased in most of the cases, aldehydes being an exception. This decrease could be associated with the formation or aggregation of new compounds onto the particles when they grow in the atmosphere.  相似文献   

12.
顶空便携气相色谱测定水中苯系物   总被引:3,自引:0,他引:3  
研究了分配常数、气液相比、温度和无机盐等对顶空分析灵敏度的影响.结果表明,这些参数对不同组分顶空灵敏度的影响有显著差异.气液相比对分配常数小的组分影响大,而温度和无机盐对分配常数大的组分影响大.提出了静态顶空/吸附热解吸/SENTEX便携气相色谱仪/微氩离子检测器测定水中4个苯系物的方法,平均相对标准偏差7.38%,平均相对误差3.46%,与标准方法比较,没有显著差异,而方法检出限低于标准方法1~2数量级.  相似文献   

13.
We propose to combine a passive sampler for polar organic compounds (POS) with a specific bioassay for phytotoxicity to assess the hazard of herbicidal compounds in surface waters. The POS consisted of an Empore disk coated with styrenedivinylbenzene deployed in a Teflon housing, which has relatively high sampling rates (e.g., approximately 1 L d(-1) for diuron). POS were deployed for 5 days in a small-scale field study in South East Queensland, Australia, in a relatively pristine environment and an urban environment to explore sensitivity towards herbicides and potential influences of non-herbicidal pollutants. Besides chemical analysis of 8 herbicides, a novel bioassay (Maxi-Imaging-PAM, IPAM) was employed to assess the phytotoxic effects of water samples and POS extracts. The IPAM allows rapid assessment of photosynthetic quantum yields of a large number of samples via chlorophyll-fluorescence imaging and the saturation pulse method. Sampling rates for several herbicides from laboratory calibrations were found to be applicable under field conditions. Toxic equivalent concentrations (with reference to the herbicide diuron) were computed from the concentrations determined by chemical analysis and the relative potency (also termed toxic equivalence factor) of the detected herbicides. There was good agreement between diuron equivalent concentrations from chemical analysis and diuron equivalent concentrations determined with the IPAM.  相似文献   

14.
建立了扩散吸附管采样,热脱附仪和气相色谱联用测定室内空气中BTEX的监测分析方法,方法的最低检出限为0.0002mg/m3。该方法使用方便、便于携带、无需电源,且与传统的泵采样方法具有较好的可比性,适合于室内空气中BTEX的监测。  相似文献   

15.
Low-molecular mass proteins rich in cysteines called metallothioneins (MT) can be considered as markers for the pollution of the environment by metals. Here, we report on suggestion for an automated procedure for the isolation of MT followed by voltammetric analysis. Primarily, we optimized the automated detection of MT using an electrochemical analyser. It was found that the most sensitive and repeatable analyses are obtained at a temperature of 4 °C for the supporting electrolyte. Further, we optimized experimental conditions for the isolation of MT by using antibody-linked paramagnetic microparticles. Under the optimal conditions (4 h long interaction between the microparticles and MT), the microparticles were tested on isolation of various amounts of MT. The lowest isolated amount of MT by antibody-linked paramagnetic microparticles was 5 μg ml(-1) of MT (50 ng). The automated procedure of MT isolation was further tested on isolation of MT from guppy fish (Poecilia reticulata) treated with silver(i) ions (50 μM AgNO(3)). The whole process lasted less than five hours and was fully automated. We attempted to correlate these results with the standard method for MT isolation. The correlation coefficient is 0.9901, which confirms that results are in good agreement. Moreover, the concentration of silver ions in tissues of fish treated with Ag(i) ions was determined by high performance liquid chromatography with electrochemical detection.  相似文献   

16.
Sulfonamide antibiotics coming from both human and veterinary medicine are among the most common emerging pollutants in freshwater. The present paper shows the successful application of passive sampling using POCIS in combination with an immunochemical ELISA technique and HPLC/MS/MS analysis to study the distribution of sulfonamides in streams around small towns in the Czech Republic, as well as around a major agglomeration of the city of Brno, including its waste water treatment plant (WWTP). Results indicated the presence of sulfonamides at most studied sites with concentrations ranging from <20 up to 736 ng of sulfamethoxazole equivalents per POCIS. Very high levels were detected in both the influent and effluent of the Brno WWTP with maxima > 8000 ng SMX per POCIS. All samplers collected down-stream of the studied towns and WWTPs clearly showed an increase in sulfonamide drug residues. Higher concentrations were determined in rivers at the city of Brno agglomeration. In agreement with other available studies, these findings indicate low efficiency of conventional WWTPs to eliminate polar pharmaceuticals such as sulfonamides. Good performance and correlation with the LC/MS results, as well as ease of use, indicate good potential for the immunochemical ELISA technique to become the screening tool for sulfonamide determination in surface waters including passive samplers.  相似文献   

17.
Diffusive sampling of a mixture of 42 volatile organic compounds (VOCs) in humidified, purified air onto the solid adsorbent Carbopack X was evaluated under controlled laboratory conditions. The evaluation included variations in sample air temperature, relative humidity and ozone concentration. Linearity of samples with loading was examined both for a constant concentration with time varied up to 24 h and for different concentrations over 24 h. Reverse diffusion and its increase with accumulation of sample were determined for all compounds. Tubes were examined for blank levels, change of blanks with storage time, and variability of blanks. Method detection limits were determined based on seven replicate samples. Based on this evaluation, 27 VOCs were selected for quantitative monitoring in the concentration range from approximately 0.1 to 4 ppbv. Comparison results of active and diffusive samples taken over 24 h and under the same simulated ambient conditions at a constant 2 ppbv were interpreted to estimate the effective diffusive sampling rates (ml min(-1)) and their uncertainties and to calculate the corresponding diffusive uptake rates (ng ppmv(-1) min(-1)).  相似文献   

18.
Air pollution problems in developing countries have gained larger fraction in the last decade especially due to non functioning and non implementation of effective air pollutioncontrol devices in industries. In industrial wastewater management, adequate treatability studies are conducted to arrive at a techno-economic treatment option. However no suchstudies were done for reducing air pollution or emission fromindustries until now in India. Little information was availableabout such studies in other countries. This article provides information about a novel technique known asflue gas treatability studies and to undertake such studies, a pilot scale system is installed in Air Pollution Control Divisionof M/s National Environmental Engineering research Institute, NEERI, Nagpur-20, India. This study is a tool for techno-economicselection of air pollution control systems specially for small/medium scale industrial emissions.  相似文献   

19.
In many countries, the presence of cyanobacteria in freshwater bodies used for both drinking water and recreational purposes is under increasing public health attention. Water managers are considering how to implement monitoring that leads to a minimization of the risks incurred by the users of potentially contaminated sites. To address this question, this study involved assessing the performance of a submersible probe for measuring phycocyanin-specific fluorescence as a function of cyanobacterial biomass, with the aim of applying it as a tool for surveillance management. Its advantages and limits compared to more traditional analyses are discussed. The monitoring of cyanobacteria in the water bodies of western France was carried out using a minifluorimeter specific to the fluorescence of phycocyanin, a pigment specific to cyanobacteria. The results are compared with the analyses recommended by the World Health Organisation (chlorophyll a and cell counting). This study based on nearly 800 samples shows a significant correlation between the phycocyanin content and the cyanobacterial biomass, expressed as the number of cells per mL (R2 = 0.73). This submersible probe is simple and rapid to use, making it possible to take into account horizontal and vertical heterogeneities in the proliferation growth. In this way, we are able to detect at an early stage the conditions that could potentially lead to a risk, in order to start sampling. Due to its sensitivity, this tool proves suitable for monitoring aimed at reducing the risks incurred by the users of contaminated sites and launching preventative actions. The use of the phycocyanin probe provides an effective tool to complement traditional analyses of cyanobacterial presence. It is suggested that a surveillance protocol based on phycocyanin concentration can significantly improved the accuracy of the extent of cyanobacterial bloom development in the light of spatial and temporal variabilities associated with these occurrences.  相似文献   

20.
downscaling procedures as a tool for integration of multiple air issues   总被引:1,自引:0,他引:1  
In assessing the risks associated with climate change,downscaling has proven useful in linking surfacechanges, at scales relevant to decision making, tolarge-scale atmospheric circulation derived from GCMoutput. Stochastic downscaling is related to synopticclimatology, weather-typing approaches (classifyingcirculation patterns) such as the Lamb Weather Typesdeveloped for the United Kingdom (UK), the EuropeanGrosswetterlagen (Bardossy and Plate, 1992) and thePerfect Prognosis (Perfect Prog) method from numericalweather prediction. The large-scale atmosphericcirculation is linked with site-specific observationsof atmospheric variables, such as precipitation, windspeed or temperature, within a specified region. Classifying each day by circulation patterns isachieved by clustering algorithms, fuzzy rule bases,neural nets or decision trees. The linkages areextended to GCM output to account for climate change. Stochastic models are developed from the probabilitydistributions for extreme events. Objective analysiscan be used to interpolate values of these models toother locations. The concepts and some applicationsare reviewed to provide a basis for extending thedownscaling approach to assessing the integrated riskof the six air issues: climate change, UV-B radiation,acid rain, transport of hazardous air pollutants, smogand suspended particulates.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号