首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The appearance of assimilable organic carbon (AOC), microbial regrowth, disinfection by-products (DBPs), and pipe corrosion in drinking water distribution systems are among those major safe drinking water issues in many countries. The water distribution system of Cheng-Ching Lake Water Treatment Plant (CCLWTP) was selected in this study to evaluate the: (1) fate and transport of AOC, DBPs [e.g., trihalomethanes (THMs), haloacetic acids (HAAs)], and other organic carbon indicators in the selected distribution system, (2) correlations between AOC (or DBPs) and major water quality parameters [e.g. dissolved oxygen (DO), free residual chlorine, and bacteria, and (3) causes and significance of corrosion problems of the water pipes in this system. In this study, seasonal water samples were collected from 13 representative locations in the distribution system for analyses of AOC, DBPs, and other water quality indicators. Results indicate that residual free chlorine concentrations in the distribution system met the drinking water standards (0.2 to 1 mg l(-1)) established by Taiwan Environmental Protection Administration (TEPA). Results show that AOC measurements correlated positively with total organic carbon (TOC) and UV-254 (an organic indicator) values in this system. Moreover, AOC concentrations at some locations were higher than the 50 microg acetate-C l(-1) standard established by Taiwan Water Company. This indicates that the microbial regrowth might be a potential water quality problem in this system. Higher DO measurements (>5.7 mg l(-1)) might cause the aerobic biodegradation of THMs and HAAs in the system, and thus, low THMs (<0.035 mg l(-1)) and HAAs (<0.019 mg l(-1)) concentrations were observed at all sampling locations. Results from the observed negative Langelier Saturation Index (LSI) values, higher Ryznar Stability Index (RSI) values, and high Fe3+ concentrations at some pipe-end locations indicate that highly oxidative and corrosive conditions occurred. This reveals that pipe replacement should be considered at these locations. These findings would be helpful in managing the water distribution system for maintaining a safe drinking water quality.  相似文献   

2.
This study investigates the microorganism growth indicator and determines the assimilable organic carbon (AOC) content at the Cheng-Ching Lake Advanced Water Treatment Plant (CCLAWTP) in Kaohsiung, Taiwan. Notably, AOC is associated with the biological stability within the water distribution network and has garnered considerable attention in the environmental engineering field in recent years. Water samples were collected from the effluent of each unit in CCLAWTP once monthly during December 2008 to November 2009. Items of water quality related to carbon concentration levels, including AOC, total organic carbon, dissolved organic carbon, UV254, and specific ultraviolent absorbance were analyzed. Analytical results demonstrate that the average AOC concentration in raw water was 83.61 ??g/L and reduced in freshwater was controlled at an average of 50 ??g/L after an advanced treatment system of roughly 54% of AOC was removed in compliance with treatment plant standards. If AOC concentrations in freshwater can be reduced, study results can provide a direction for improving water treatment capabilities.  相似文献   

3.
Stability of drinking water can be indicated by the assimilable organic carbon (AOC). This AOC value represents the regrowth capacity of microorganisms and has large impacts on the quality of drinking water in a distribution system. With respect to the effectiveness of traditional and advanced processing methods in removing trace organic compounds (including TOC, DOC, UV254, and AOC) from water, experimental results indicate that the removal rate of AOC at the Cheng Ching Lake water treatment plant (which utilizes advanced water treatment processes, and is hereinafter referred to as CCLWTP) is 54%, while the removal rate of AOC at the Gong Yuan water treatment plant (which uses traditional water treatment processes, and is hereinafter referred to as GYWTP) is 36%. In advanced water treatment units, new coagulation–sedimentation processes, rapid filters, and biological activated carbon filters can effectively remove AOC, total organic carbon (TOC), and dissolved organic carbon (DOC). In traditional water treatment units, coagulation–sedimentation processes are most effective in removing AOC. Simulation results and calculations made using the AutoNet method indicate that TOC, TDS, NH3-N, and NO3-N should be regularly monitored in the CCLWTP, and that TOC, temperature, and NH3-N should be regularly monitored in the GYWTP.  相似文献   

4.
Heterotrophic bacteria in drinking water distribution system: a review   总被引:1,自引:0,他引:1  
The microbiological quality of drinking water in municipal water distribution systems (WDS) depends on several factors. Free residual chlorine and/or chloramines are typically used to minimize bacterial recontamination and/or regrowth in WDS. Despite such preventive measures, regrowth of heterotrophic (HPC) and opportunistic bacteria in bulk water and biofilms has yet to be controlled completely. No approach has shown complete success in eliminating biofilms or HPC bacteria from bulk water and pipe surfaces. Biofilms can provide shelter for pathogenic bacteria and protect these bacteria from disinfectants. Some HPC bacteria may be associated with aesthetic and non-life threatening diseases. Research to date has achieved important success in understanding occurrence and regrowth of bacteria in bulk water and biofilms in WDS. To achieve comprehensive understanding and to provide efficient control against bacteria regrowth, future research on bacteria regrowth dynamics and their implications is warranted. In this study, a review was performed on the literature published in this area. The findings and limitations of these papers are summarized. Occurrences of bacteria in WDS, factors affecting bacteria regrowth in bulk water and biofilms, bacteria control strategies, sources of nutrients, human health risks from bacterial exposure, modelling of bacteria regrowth and methods of bacteria sampling and detection and quantification are investigated. Advances to date are noted, and future research needs are identified. Finally, research directions are proposed to effectively control HPC and opportunistic bacteria in bulk water and biofilms in WDS.  相似文献   

5.
This present study assessed the chlorine tolerance of some Citrobacter species recovered from secondary effluents from the clarifiers of two wastewater treatment plants in the Eastern Cape, South Africa. The bacterial survival, chlorine lethal dose and inactivation kinetics at lethal doses were examined. Inactivation of the test bacteria (n = 20) at the recommended dose of 0.5 mg/l for 30 min exposure showed a progressive reduction in bacterial population from 4 to 5 log reduction and residuals ranged between 0.12 and 0.46 mg/l. The bactericidal activity of chlorine increased at higher dosages with a substantial reduction in viability of the bacteria and complete inactivation of the bacterial population at a lethal dose of 0.75 and 1.0 mg/l in 30 min. For the inactivation kinetics, bactericidal activity of chlorine increased with time showing a 3.67–5.4 log reduction in 10 min, 4.0–5.6 log reduction in 20 min and above 6.3 log reductions to complete sterilization of bacterial population over 30 min for all the entire test Citrobacter isolates used in this study. Furthermore, there was a strong correlation (R 2 > 0.84) between bacteria inactivation and increase in contact time. This study appears to have provided support for laboratory evidence of bacterial tolerance to chlorine disinfection at current recommended dose (0.5 mg/l for 30 min), and chlorine concentration between 0.75 and 1.0 mg/l was found to have a better disinfecting capacity to check tolerance of Citrobacter species.  相似文献   

6.
New environmental standards for protecting aquatic organisms for zinc (e.g., 0.03 mg/L) in surface waters were set in Japan in 2003. Although wastewater effluent might be one of the major pathways of zinc to public water bodies in Japan, current status of concentration of zinc in wastewater effluent was not clear due to higher detection limits (e.g., 0.5 mg/L) than the level required by the new regulations. This study aims at assessing current status of zinc in wastewater effluent in Japan to revise wastewater effluent standards for protecting aquatic organisms. Survey of zinc in wastewater treatment plants (WWTPs) was carried out in Japan in 2005, setting the detection limits at least 0.01 mg/L. The results of the survey suggested the difficulty to remove zinc (especially dissolved zinc) with conventional activated sludge treatment if concentration of zinc in influent was relatively low. And it was suggested that high concentration of dissolved zinc might be derived from some industries discharging high concentration of zinc. The concentration of zinc in wastewater influent without industrial discharges was about 0.1 mg/L which might be lower than that in wastewater from industries discharging high concentration of zinc. Finally, effluent standards for point sources including WWTPs to public water bodies were set at 2 mg/L in 2006. Based on the results of the survey that it was difficult to remove dissolved zinc discharged from industries at WWTPs, the effluent standards from industries to sewerage were set at the same value of the effluent standards from WWTPs to public water bodies.  相似文献   

7.
The impact of the total organic carbon (TOC), chlorine dosage, water temperature, reaction time, pH, and seasonal variation on the formation of haloacetic acids (HAAs) in the Karoon River in Iran was studied. The results showed that dichloroacetic acid and trichloroacetic acid were the most detected HAA5. The HAA5 formation potential (HAA5FP) levels in the Karoon River water in spring time, when the water TOC content exceeded 4 mg/L, were 1.38 times higher than during the winter season, when the water TOC content was below 3.5 mg/L. There was not a strong correlation between the HAA5FP and the residence time for the Karoon River water. For the range of the water temperatures studied, there was little variation in the HAA5FP in cold water, but in warmer water, the values of the HAA5FP varied quickly.  相似文献   

8.
To ascertain the quality of drinking water being supplied, water quality monitoring and surveillance was conducted in Gangtok city at various treatment stages, service reservoirs, distribution network, public standposts, and households. No significant change in raw water quality was observed on day-to-day basis. Residual chlorine was found in the range of nil to 0.2 mg/l in the sump water/finished water. Throughout the year (i.e., during summer, winter, and monsoon seasons), the total coliform and fecal coliform counts were ranged from nil to 7 CFU/100 ml and nil to 3 CFU/100 ml, respectively, in sump water of Selep and VIP complex water treatment plant; however, at consumer end, those were observed as nil to 210 CFU/100 ml and nil to 90 CFU/100 ml, respectively. These variations in bacterial counts among the different service reservoirs and consumer ends may be attributed to the general management practices for maintenance of service reservoirs and the possibility of enroute contamination. Evaluation of the raw water quality indicates that the water is suitable for drinking after conventional treatment followed by disinfection. The finished water quality meets the level of standards described as per Bureau of Indian Standard specifications (BIS:10500 1991) for potability in terms of its physicochemical characteristics.  相似文献   

9.
This study was primarily aimed at investigating the physicochemical and microbial quality of water in 14 such dugouts from five districts in the northern region of Ghana. Results obtained suggest that except for colour, turbidity, total iron and manganese, many physicochemical parameters were either within or close to the World Health Organisation’s acceptable limits for drinking water. Generally, colour ranged from 5 to 750 Hz (mean 175 Hz), turbidity from 0.65 to 568 nephelometric turbidity units (NTU; mean 87.9 NTU), total iron from 0.07 to 7.85 mg/L (mean 1.0 mg/L) and manganese from 0.03 to 1.59 mg/L (mean 0.50 mg/L). Coliform counts in water from all the dugouts in both wet and dry seasons were, however, above the recommended limits for drinking water. Total and faecal coliforms ranged from 125 to 68,000 colony forming units (cfu)/100 mL (mean 10,623 cfu/100 mL) and <?1 to 19,000 cfu/100 mL (mean 1,310 cfu /100 mL), respectively. The poor microbial quality, as indicated by the analytically significant presence of coliform bacteria in all samples of dugout water, strongly suggests susceptibility and exposure to waterborne diseases of, and consequent health implications on, the many people who continuously patronise these vital water resources throughout the year. In particular, more proactive sustainable water management options, such as introduction to communities of simple but cost-effective purification techniques for water drawn from dugouts for drinking purposes, education and information dissemination to the water users to ensure environmentally hygienic practices around dugouts, may be needed.  相似文献   

10.
The occurrence, concentrations, patterns, and loads of 17 2,3,7,8-substituted congeners of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) were determined in treated wastewater collected at the outlets from 14 wastewater treatment plants (WTPs), divided into three size categories. The analysis also considered the effect of wastewater outflow on the final concentrations of PCDDs/Fs, as the samples were collected during flooding and stable hydrological conditions. None of the studied WTPs were found to completely remove toxic congeners of PCDDs/Fs from wastewater: the PCDD concentrations in the outgoing effluent during stable wastewater flow ranged from 2.99 to 177.19 pg/L, PCDFs from 6.05 to 51.30 pg/L, and the Toxic Equivalent (TEQ) was between 0.94 and 4.87 pg/L. The results from high wastewater flow were less diversified, ranging from 5.04 to 8.85 pg/L for PCDDs, from 11.47 to 32.33 pg/L for PCDFs and from 2.00 to 4.65 pg/L for TEQ. The smallest WTPs demonstrated the highest average total and TEQ concentrations due to limited volume, short retention time and outdated technology, and, hence, insufficient treatment efficiency. The largest WTPs have the potential to substantially affect the quality of river water, as despite being associated with the lowest concentrations, they released much greater volumes of treated wastewater and, hence, the greatest amounts of analyzed compounds. Elevated TEQ values were observed at high flow in all WTP size categories indicating the impact of high and stable wastewater flow on the concentrations of the observed PCDDs/Fs.  相似文献   

11.
Concern over the presence of fecal coliform in public drinking water supplies has been expressed in recent years in Pakistan since it has been regarded as pathogenic organism of prime importance in gastroenteritis. Two major drinking water distribution systems in the Cantt area of Rawalpindi district covering the Westridge and Tench areas was monitored over a 2-month period to determine the prevalence of fecal coliform and chlorine residual. The collected samples were examined for total chlorine, free chlorine residual, chloramines, total coliforms, fecal coliforms, and turbidity. The drinking water quality monitoring in the distribution network was performed by collecting samples from water source, overhead reservoir, and residential taps. In the Westridge area, total chlorine varied from the lowest value of 0.27 mg/L at Station # W-5 to the highest value of 0.42 mg/L at Station # W-2, total coliforms varied from 1.1 to 3.6 most probable number (MPN)/100 mL with presence of Escherichia coli in all samples, total dissolved solids (TDS) ranged from 199.5 to 205 mg/L, conductivity fluctuated between 399 and 411 microS/cm, and turbidity varied from 0.43 to 0.73 NTU. In the Tench area, the value of total chlorine ranged from 0.14 mg/L at Station # T-7 to 0.55 mg/L at Station # T-1. Total coliform varied from 3.6 to 5.1 MPN/100 mL and fecal coliform were detected at all the stations except at Station # T-1. TDS ranged from 201.4 to 257 mg/L, conductivity varied from 343 to 513 microS/cm, and turbidity ranged between 0.66 and 1.55 NTU. It is recommended to the respective agencies to ensure that the chlorine residual is available at consumer end.  相似文献   

12.
系统研究了反应时间、水温、显色剂的用量及pH对游离性余氯测定的影响,优化选择最佳测定条件为控制水样pH<8,水温25℃,显色剂用量2.5 ml,加入显色剂后立即比色测定游离性余氯。在此条件下,测定3种生活饮用水游离性余氯,回收率为96.7%~99.8%,测定结果与《生活饮用水标准检验法》(GB 5750-85)中37.3滴定法颇为一致。  相似文献   

13.
In studies on the formation of disinfection byproducts (DBPs), it is necessary to scavenge residual active (oxidizing) chlorine in order to fix the chlorination byproducts (such as haloethanoates) at a point in time. Such research projects often have distinct needs from requirements for regulatory compliance monitoring. Thus, methods designed for compliance monitoring are not always directly applicable, but must be adapted. This research describes an adaptation of EPA Method 552 in which ascorbic acid treatment is shown to be a satisfactory means for reducing residual oxidizing chlorine, i.e., HOCl, ClO-, and Cl2, prior to determining concentrations of halocarboxylates. Ascorbic acid rapidly reduces oxidizing chlorine compounds, and it has the advantage of producing inorganic halides and dehydroascorbic acid as opposed to halogenated organic molecules as byproducts. In deionized water and a sample of chlorinated tap water, systematic biases relative to strict adherence to Method 552 were precise and could be corrected for using similarly treated standards and analyte-fortified (spiked) samples. This was demonstrated for the quantitation of chloroethanoate, bromoethanoate, 2,2-dichloropropanoate (dalapon), trichloroethanoate, bromochloroethanoate, and bromodichlorocthanoate when extracted, as the acids, into tert-butyl methyl ether (MTBE) and esterified with diazomethane prior to gas chromatography with electron capture detection (GC-ECD). Recoveries for chloroethanoate, bromoethanoate, dalapon, dichloroethanoate, trichloroethanoate, bromochloroethanoate, bromodichloroethanoate, dibromoethanoate, and 2-bromopropanoate at concentrations near the lower limit of detection were acceptable. Ascorbic acid reduction appears to be the best option presently available when there is a need to quench residual oxidants fast in a DBP formation study without generating other halospecies but must be implemented cautiously to ensure no untoward interactions in the matrix.  相似文献   

14.
The aim of this study was to estimate the risk for caries and fluorosis in a desertification area, applying the calcium/fluoride concentration ratio of underground water and the quality of water in a selected geographical region. This study was performed in the municipality of São João do Rio do Peixe, located in the tropical semiarid lands of Brazil. A total of 111 groundwater samples were collected. Fluoride concentration varied from 0.11 to 9.33 mg/L. Thirty percent of all samples analyzed showed values above 1.5 mg/L, while 64 % were above the ideal limit of 0.7 mg/L. Mean calcium concentration was 47.6 mg/L, and 14.4 % of all samples presented values above the WHO acceptable limits. The proportional value of calcium/fluoride in water showed that only 12 % of the samples were suitable for dental caries prevention with minimal risk for dental fluorosis. Mapping of the fluoride distribution indicated that approximately 2,465 people could be affected by dental fluorosis and 1,057 people might be affected by skeletal fluorosis. It can be concluded that, in addition to fluoride, many water parameters were not suitable for the drinking water. Mapping out calcium/fluoride ratio may indicate areas of water suitability for caries control, whereas the fluoride concentration solely can indicate the areas with the risk for fluorosis. This approach can be relevant for health authorities for identifying communities where dental caries or dental fluorosis is prevalent.  相似文献   

15.
The ground water quality of District Nainital (Uttarakhand, India) has been assessed to see the suitability of ground water for drinking and irrigation applications. This is a two-part series paper and this paper examines the suitability of ground water including spring water for drinking purposes. Forty ground water samples (including 28 spring samples) were collected during pre- and post-monsoon seasons and analyzed for various water quality constituents. The hydrochemical and bacteriological data was analyzed with reference to BIS and WHO standards and their hydrochemical facies were determined. The concentration of total dissolved solids exceeds the desirable limit of 500 mg/L in about 10% of the samples, alkalinity values exceed the desirable limit of 200 mg/L in about 30% of the samples, and total hardness values exceed the desirable limit of 300 mg/L in 15% of the samples. However, no sample crosses the maximum permissible limit for TDS, alkalinity, hardness, calcium, magnesium, chloride, sulfate, nitrate, and fluoride. The concentration of chloride, sulfate, nitrate, and fluoride are well within the desirable limit at all the locations. The bacteriological analysis of the samples does not show any sign of bacterial contamination in hand pump and tube-well water samples. However, in the case of spring water samples, six samples exceed the permissible limit of ten coliforms per 100 ml of sample. It is recommended that water drawn from such sources should be properly disinfected before being used for drinking and other domestic applications. Among the metal ions, the concentration of iron and lead exceeds the permissible limit at one location whereas the concentration of nickel exceeds the permissible limit in 60 and 32.5% of the samples during pre- and post-monsoon seasons, respectively. The grouping of samples according to their hydrochemical facies indicates that majority of the samples fall in Ca–Mg–HCO3 hydrochemical facies.  相似文献   

16.
456 water samples collected from 152 water sources in 2006 were analyzed for 21 volatile organic compounds (VOCs). Concentrations of 21 VOCs ranged from below method detection limits of the laboratory to 7.65 ??g/L (toluene), but seldom exceeded the concentration limits set in the National Drinking Water Quality Standards (GB5749-2006) or the National Environmental Quality Standards for Surface Water (GB3838-2002) of China. Of the 21 individual VOCs analyzed, 11 VOCs were detected in at least one sample at or above 1.0 ??g/L; 6.6% of the water samples had a detection of at least one VOC at or above 1.0 ??g/L, and 2.6% had a detection of at least two VOCs at or above 1.0 ??g/L. Based on the statistical data of detection frequencies above the method detection limits, 75% of the samples detected at least one VOC, and 65% of the samples detected at least two VOCs. Chloroform, toluene, and 1,2-dichloroethene were the three most frequently detected VOCs, with detection frequencies of 76.97%, 68.42%, and 44.08%, respectively. Volatile halogenated hydrocarbons and gasoline components were the two most frequently detected VOC groups.  相似文献   

17.
This paper reports a reconnaissance survey of the concentrations of sterol compounds (as indicators of fecal contamination) in a large water supply system in southeast Australia comprising a network of rivers, channels, and drains. Levels of coprostanol and cholestanol were determined in surface water and bottom sediment using gas chromatography–mass spectrometry analysis across 17 strategic sampling sites and over 12 months. Clear differences in the levels of fecal contamination were observed among sites. Four sites routinely contained high levels of the fecal indicator sterols indicated from surface water and sediment sample analysis. Coprostanol concentrations at each location varied from 0 ng/L at the reference site to 11,327 ng/L in a surface water sample of a drain directly downstream of a knackery. The majority of the sites contained coprostanol in the range of 500 to 800 ng/L. Since no fecal-associated sterol compounds were detected at the external reference sites, these were assumed to be free from fecal contamination. Sewage water discharge and/or substantial water runoff maybe the principal factors contributing to fecal contamination of the supply drains and channels.  相似文献   

18.
A study was undertaken to assess the quality of groundwaters in the Kathmandu Valley, Nepal. The groundwater samples were randomly collected from shallow well, tube well, and deep-tube wells located at different places of Kathmandu, Lalitpur, and Bhaktapur districts in the Kathmandu valley. Physical, chemical, and microbiological parameters of the samples were evaluated to estimate the groundwater quality for drinking water. It was found that the groundwater in the valley is vulnerable to drink due to presence of iron and coliform bacteria. Iron was estimated to be much higher then the acceptable limit of World Health Organization (WHO) drinking-water quality guidelines (1.9 mg/L). Total coliform bacteria enumerated in groundwaters significantly exceeded the drinking-water quality standard and observed maximum coliform (267 CFU/100 mL) in shallow wells. The electrical conductivity and turbidity were found to be 875 ??S/cm and 55 NTU, respectively, which are above the WHO recommendations for drinking water guidelines. However, pH value was measured within the acceptable limit. Arsenic, chloride, fluoride, and hardness concentrations were found to be in agreement with the recommendations of WHO drinking-water quality guidelines.  相似文献   

19.
碘化钾-淀粉试纸法测定余氯   总被引:4,自引:0,他引:4  
基于余氯对碘化钾的氧化作用和碘淀粉反应,本文提出了测定余氯的碘化钾-淀粉试纸法。研究了最佳测试条件,用于测定医院污水中的余氯,获得满意结果。测量范围为1.0-10.0mg/L。  相似文献   

20.
The occurrences of pharmaceuticals and personal care products as emerging organic contaminants (EOCs) have been reported in several countries of the world except from African countries. This study was therefore conducted to investigate the occurrence of nine antibiotics, five antipyretics, atenolol, bezafibrate, and caffeine in wastewater and surface water samples from the Umgeni River. The water samples were extracted with solid-phase extraction using hydrophilic-lipophilic balance (HLB) and C-18 cartridges for the acidic and neutral drugs, respectively. The quantification was carried out with high-performance liquid chromatography-diode array detector (HPLC-DAD) using the standard addition method. The method limits of detections were in the range of 0.14–0.97 μg/L while the recoveries were between 53.8 and 108.1 %. The wastewater had 100 % occurrence of the analytes studied, with caffeine having the highest concentration at 61?±?5 μg/L and nalidixic acid being the most observed antibiotic at 31?±?3 μg/L. The waste treatment process reduced the influent concentrations by 43.0–94.2 % before discharge except for atenolol removal that is lower. The concentrations of the analytes were lower in the surface water with most compounds having concentrations below 10 μg/L except acetaminophen and atenolol. The estuary mouth and Blue Lagoon had the highest concentrations of some of the compounds in surface water which depict downstream load. The factors governing the fate and mobility of these compounds in this environment are not fully understood yet and will require further studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号