首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Dioxins like polychlorinated dibenzo-p-dioxins (PCSDDs), polychlorinated dibenzofurans (PCDFs) and polychlorinated biphenyls (PCBs) are mainly emitted from waste incinerators (WIs) and have become an international research focus because of its serious concerns over the adverse health effects. The detoxification of PCCDs/Fs and PCBs is very difficult because of their stable chemical structure. A significant hydrodechlorination/detoxification of polychlorinated 1-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and polychlorinated biphenyls (PCBs) were achieved in fly ash by using an aqueous mixture of calcium hydroxide and sulfur. Two different fly ashes were studied: originating from municipal waste incinerator (FA1) and industrial waste incinerator (FA2). They were heated with the aqueous mixture at 150 °C for 30 or 60 min with agitation. Higher decomposition (87%) and detoxification (87.7%) of PCDD/Fs and PCBs were achieved at 150 °C with two runs; every run was for 30 min, compared to one run for 60 min. FA2 gave higher decomposition and detoxification as compared to FA1, which might be due to higher metal content that played a catalytic role to decompose and detoxify the PCDDs, PCDFs and PCBs. The decomposition and detoxification of PCDFs in fly ash was higher than PCDDs and was augmented with increasing number of chlorides on aromatic compounds. As the highly significant decomposition and detoxification of higher concentration of PCDD/Fs and PCBs were achieved in 1 hour without additive catalyst and at low temperature of 150 °C, therefore, the developed method is cost effective and most suitable to apply on commercial/industrial level. The detail results of hydrodechlorination/detoxification of PCDD, PCDFs at different conditions are described and its mechanism is discussed.  相似文献   

2.
The toxic equivalency (TEQ) values of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) are predicted with a model based on the homologue concentrations measured from a laboratory-scale reactor (124 data points), a package boiler (61 data points), and operating municipal waste incinerators (114 data points). Regardless of the three scales and types of equipment, the different temperature profiles, sampling emissions and/or solids (fly ash), and the various chemical and physical properties of the fuels, all the PCDF plots showed highly linear correlations (R(2)>0.99). The fitting lines of the reactor and the boiler data were almost linear with slope of unity, whereas the slope of the municipal waste incinerator data was 0.86, which is caused by higher predicted values for samples with high measured TEQ. The strong correlation also implies that each of the 10 toxic PCDF congeners has a constant concentration relative to its respective total homologue concentration despite a wide range of facility types and combustion conditions. The PCDD plots showed significant scatter and poor linearity, which implies that the relative concentration of PCDD TEQ congeners is more sensitive to variations in reaction conditions than that of the PCDF congeners.  相似文献   

3.
Effects of carbon concentration and Cu additive in simulated fly ash (SFA) and real fly ash (RFA) on the formation of polychlorinated dibenzofurans (PCDFs), polychlorinated dibenzo-p-dioxins (PCDDs), chlorobenzenes, and polychlorinated biphenyls which were all regarded as persistent chlorinated aromatics in iron ore sintering were investigated. In the annealing process of SFA with various carbon contents, the yield of chlorinated aromatics and the I-TEQ obtained their maximum at 10 wt% carbon content. Active carbon in SFA acted as the carbon source as well as an adsorbent which led to higher production of PCDD/F in solid phase at 10 wt% carbon content. The increase of carbon content will be beneficial on the formation of 2,3,7,8-Chloro-substituted PCDF compared with 2,3,7,8-Chloro-substituted PCDD. In addition, the CuCl2·2H2O was a much more powerful catalyst in the formation of chlorinated aromatic compounds compared with elementary Cu, since it served as both a catalyst and a chlorine donor. However, the RFA behaved similarly with SFA with elementary Cu in the formation of chlorinated aromatic compounds. The effect of carbon content and copper additives on formation of 2,3,7,8-chloro-substituted congeners displayed similar characteristics with the tetra- to octa-PCDD/F isomers and even the total PCDD/Fs.  相似文献   

4.
The formation of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDDs/Fs) from carbon that was produced by the pyrolysis of paper fibers and from wood charcoal was investigated experimentally. Fibers obtained from filter paper were pyrolyzed at 300° and 800°C to produce low- and high-temperature carbon samples. The two types of carbon and wood charcoal were mixed with silica (SiO2) and trace copper oxide to produce three synthetic fly ash samples. Experiments to measure the formation of PCCDs/Fs from the three ash samples were conducted using a bench-scale reactor. The two carbon samples derived from paper fibers generated more PCDDs/Fs than was generated by the wood charcoal. The PCDDs/Fs generated by the low-temperature carbon and by the wood charcoal were dominated by the lower-chlorinated PCDFs. Such unique homologue distribution patterns are very similar to those generated by the open burning of household waste. The high-temperature carbon generated more highly chlorinated PCDDs/Fs. The effect of pyrolysis temperature on the de novo formation of PCDDs/Fs from residual carbon is discussed. Paper and paper products contained in household waste are likely to be the source of unburned carbon that contributes to high PCDD/F emissions in the open burning of household waste.  相似文献   

5.
The huge amount of medical waste (MW) has caused a tough challenge to environmental protection in China because of its serious infectious potential. At present, incineration is the most common technology for MW disposal. Unfortunately, the medical waste incinerator (MWI) is considered one of the major sources of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). This study was conducted to investigate the generation and the components of MW; the fingerprint of PCDD/Fs in MWI; and PCDD/F, polychlorinated biphenyl (PCB) and hexachlorobenzene concentrations in residue ash. The estimated annual production of MW was estimated to be 0.97 million tons in China in 2008; in addition, plastic and rubber accounted for 24.5% of MW contents. PCDD/F emissions from MWI could be divided into two main groups according their fingerprints, and the ratio of PCDFs/PCDDs was mostly over 1.5, with a mean value of 3.43. The toxic equivalent of PCDD/Fs was over 30 times that of the value of PCBs in the residue ash, and PCDD/F contents in fly ash accounted for approximately 67% of the total output of PCDD/Fs, which was in line with the UNEP default emission factors for MWI (class 3, 63.7%).  相似文献   

6.
The present paper refers to the results of a research project on the polychlorinated dibenzyil-p-dioxin (PCDD) and polychlorinated dibenzofurans repartition in particulate and volatile phase in emissions from municipal solid waste incinerators. The distribution of such micropollutants between the different phases is analyzed in terms of absolute weights and in terms of 2, 3, 7, 8 TCDD Equivalents. This paper shows that more than half of the total content of PCDD/Fs emitted are adsorbed in the fly ash, with the remaining part in the volatile phase. Such repartition is inverted if the PCDD/Fs are expressed in terms of 2, 3, 7, 8 TCDD Equivalent.  相似文献   

7.
Sludge as dioxins suppressant in hospital waste incineration   总被引:1,自引:0,他引:1  
Nitrogen containing compounds such as ammonia, urea and amines can effectively inhibit the formation of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). Sewage sludge accumulates both sulfur and nitrogen during wastewater treatment so it could be used to reduce PCDD/Fs formation. Indeed, it is observed in this study that the gas evolving from the sludge drying process can significantly suppress chlorobenzene (CBz) and PCDD/Fs formation from fly ash collected from a hospital waste incinerator. For instance, the reduction of hexachlorobenzene (HxCBz) and PCDD/Fs amount was 92.1% and 78.7%, respectively, when the drying gas evolving from 2g sludge flew through 2g fly ash. These tests were conducted in the frame of projects devoted to hospital waste incineration. The disposal technology for hospital waste (HW), developed in this institute, features rotary kiln pyrolysis combined with post-combustion followed by flue gas cleaning. Hence, some preliminary tests were devoted to investigate dioxins suppression by co-pyrolysis and co-combustion of polyvinyl chloride (PVC) and sludge in lab scale. More experimental research will be conducted to appropriately assess these effects of sludge on PCDD/Fs emissions during co-pyrolysis/combustion of HW and sludge.  相似文献   

8.
Hospital solid waste incinerator (HSWI) fly ash contains a large number of carbon constituents including powder activated carbon and unburned carbon, which are the major source of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in fly ash. Therefore, the removal of carbon constituents could reduce PCDD/Fs in fly ash greatly. In this study, the effects of the main flotation parameters on the removal of carbon constituents were investigated, and the characteristics of the final product were evaluated. The results showed that loss on ignition (LOI) of fly ash increased from 11.1% to 31.6% during conditioning process. By optimizing the flotation parameters at slurry concentration 0.05 kg/l, kerosene dosage 12 kg/t, frother dosage 3 kg/t and air flow rate 0.06 m3/h, 92.7% of the carbon constituents were removed from the raw fly ash. Under these conditions, the froth product has LOI of 56.35% and calorific values of 12.5 MJ/kg, LOI in the tailings was below 5%, and the total toxic equivalent (TEQ) of PCDD/Fs decreased from 5.61 ng-TEQ/g in the raw fly ash to 1.47 ng-TEQ/g in the tailings. The results show that column flotation is a potential technology for simultaneous separation of carbon constituents and PCDD/Fs from HSWI fly ash.  相似文献   

9.
The presence of endocrine disrupting chemicals (EDCs) in the environment has wide-ranging potential ecological and health impacts on animals and humans. A significant amount of experimental and theoretical work has been performed the examining formation and control of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs), which account for only part of the EDCs being emitted from combustion devices. Generally accepted mechanistic theories for PCDD/F formation propose heterogeneous reactions in the cooler regions of the combustor involving gas-phase organic precursors (such as chlorobenzenes or chlorophenols), a chlorine donor [such as hydrogen chloride (HCl)], and a flyash-bound metallic catalyst (such as copper chloride). There is evidence that some other proposed EDCs, including polychlorinated biphenyls (PCBs), are formed through a similar mechanistic pathway as PCDD/Fs. In addition, there is evidence that certain important steps in the catalytic reaction between the copper catalyst and the organic precursors may suggest a common rate limiting step for the heterogeneous formation of the previously mentioned EDCs. This paper reports on a bench-scale experimental study to characterize a newly built reactor system that was built to: produce levels and distributions of PCDD/F production similar to those achieved by previous researchers; verify similar responses to changes in independent variables; examine the hypothesis that PCB formation rates exhibit trends similar to PCDD/F formation rates as reactor variables are changed; and begin to explore the dependence of PCB formation on temperature and precursor type. The reactor system has been built, and initial reactor characterization studies have been performed. Initial experiments yielded results that support the hypothesis of a similar formation mechanism of PCBs and PCDD/Fs in combustors. Initial experiments uncovered potential deficiencies with the reactor system and the experimental procedures and have suggested corrective action to improve the experimental system.  相似文献   

10.
The characterization of PCDD/Fs and heavy metals in the flue gas and fly ash of Harbin municipal solid waste (MSW) incineration plant, located in the northeast of China, was investigated in this study. The MSW was treated in a twin internal fluidized (TIF) bed incinerator. The results indicate that the emission of PCDD/Fs into the environment is 0.02 ng I-TEQ/m3 and the level of PCDD/Fs in the fabric filter fly ash is 0.7982 ng I-TEQ/g. The leachability levels of Pb, Cd and Hg in the fly ash are below the limits of environmental protection standard in China. However, the contents of Cu, Zn, and Hg are high in the fly ash. This suggests that the fly ash is a hazardous waste that requires special treatment and disposal. The practice of more than four years of operation shows that the TIF bed incinerator is very suitable and practical for China.  相似文献   

11.
An efficient dechlorination/detroxification method for p-nitrochlorobenzene, p-chloroanisole and 1-chloronaphthalene on municipal waste incinerator fly ash in presence of reducing agents with water/alcohol mixtures was developed. Dechlorination% was higher in water/isopropanol mixture at temperature <100 °C. Metal contents of fly ash played a vital role in enhancing dechlorination at low temperature. Moreover, the fly ash particles provided the surface to accomplish reduction and substitution reactions by adsorbing the chlorinated aromatic compound, hydrogen and hydroxyl ions. The mechanism of dechlorination was envisaged.  相似文献   

12.
The leaching behavior of dioxins from landfill containing bottom ash and fly ash from municipal solid waste incineration has been investigated by leaching tests with pure water, non-ionic surfactant solutions, ethanol solutions, or acetic acid solutions as elution solvents for a large-scale cylindrical column packed with ash. Larger amounts of dioxins were eluted from both bottom ash and fly ash with ethanol solution and acetic acid solution than with pure water. Large quantities of dioxins were leached from fly ash but not bottom ash by non-ionic surfactant solutions. The patterns of distribution of the dioxin congeners in the leachates were very similar to those in the bottom ash or fly ash from which they were derived.  相似文献   

13.
Pollutant emissions from co-firing of refuse derived fuel (RDF) and coal were investigated in a vortexing fluidized bed combustor (VFBC). RDF-5 was made of common municipal solid waste (MSW). CaCO3 was injected in the combustor to absorb HCl at 850 °C. The results show that NOx and HCl emissions increase with RDF-5 co-firing ratio. The NOx concentration in flue gas at the bottom of the combustor is higher than that at the top. However, the trend of HCl released is reverse compared with NOx emissions. It was found that the HCl concentration decreases with increasing the molar ratio of Ca/Cl. However, the effect of CaCO3 addition on HCl retention is not significant when the molar ratio of Ca/Cl is higher than 5. The chlorine content in fly ash increases obviously with the molar ratio of Ca/Cl. PCDD/Fs emissions decrease slightly with an addition of CaCO3. In this study incomplete combustion is regarded as the main cause for polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) formation.  相似文献   

14.
Presence, sources and behaviour of polybrominated diphenyl ethers (PBDEs) and polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) were evaluated in Spanish sewage sludge. A total of 120 samples were seasonally collected from October 2005 to September 2006 at 31 urban wastewater treatment plants (WWTPs). Concentrations of PBDEs (ranging between 57.5 and 2606 ng/g dry weight) were two to three orders of magnitude higher than those obtained for PCDDs (0.17-5.03 ng/g d.w.) and PCDFs (0.05-3.07 ng/g d.w.). All the samples presented International Toxicity Equivalents (I-TEQ) levels (ranging between 2.06 and 44.4 ng/kg d.w.) below the limit values proposed by European Union for land application. Congener patterns evaluation revealed that the use of Deca-BDE commercial mixture seems to be the major source of PBDEs in the sludge. Nevertheless, origin of PCDD/Fs should be related to atmospheric deposition, faeces and presence of PCDD/Fs precursors such as pentachlorophenol in the sludge. No correlations (p > 0.05) were found between pollutant concentrations (PBDEs and PCDD/Fs) and wastewater treatment plant (WWTP) characteristics (capacity nor sludge rate). Lower levels of PBDEs and PCDFs were found in WWTPs using biological nitrogen and phosphorous elimination, suggesting that these compounds are susceptible of microbial elimination. According to our knowledge, this is the first work comparing together both PBDEs and PCDD/Fs sludge patterns.  相似文献   

15.
The input and output samples from existing large-scale municipal solid waste incinerator (MSWI) were collected and analyzed for polychlorinated dibenzo-р-dioxins and dibenzofurans (PCDD/Fs) in this study, aiming to evaluate PCDD/F characteristic and the corresponding mass balance through the whole system. The grate-type MSWI is equipped with semi-dry scrubber, activated carbon injection, and bag filter as air pollutant control devices (APCDs). Results showed that on the output side, the stack gas, bottom ash and fly ash presented their mean dioxin levels of 0.078 ng I-TEQ/Nm(3), 12.94 ng I-TEQ/kg and 858 ng I-TEQ/kg, respectively, and showed large similarities in congener profiles. Instead, on the input side, the municipal solid waste (MSW) presented a mean dioxin level of 15.56 ng I-TEQ/kg and a remarkable difference in congener profiles compared with those of the output. The dioxin mass balance demonstrated that the annual dioxin input value was around 5.38 g I-TEQ/yr, lower than the total output value (7.62 g I-TEQ/yr), signifying a positive dioxin balance of about 2.25 g I-TEQ/yr.  相似文献   

16.
Polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) are formed during waste incineration and in waste-to-energy boilers. Incomplete combustion, too short residence times at low combustion temperatures (<700 °C), incineration of electronic waste and plastic waste containing chlorine are all factors influencing the formation of PCDD/Fs in boilers. The impact of chlorine and catalysing metals (such as copper and iron) in the fuel on PCDD/F formation was studied in a 12 MWth circulating fluidised bed (CFB) boiler. The PCDD/F concentrations in the raw gas after the convection pass of the boiler and in the fly ashes were compared. The fuel types were a so-called clean biomass with low content of chlorine, biomass with enhanced content of chlorine from supply of PVC, and solid recovered fuel (SRF) which is a waste fuel containing higher concentrations of both chlorine, and catalysing metals. The PCDD/F formation increased for the biomass with enhanced chlorine content and it was significantly reduced in the raw gas as well as in the fly ashes by injection of ammonium sulphate. A link, the alkali chloride track, is demonstrated between the level of alkali chlorides in the gas phase, the chlorine content in the deposits in the convection pass and finally the PCDD/F formation. The formation of PCDD/Fs was also significantly reduced during co-combustion of SRF with municipal sewage sludge (MSS) compared to when SRF was fired without MSS as additional fuel.  相似文献   

17.
Open dumping sites in Surabaya and Palembang, Indonesia, have been studied to investigate emissions of polychlorinated dibenzo-para-dioxins and dibenzofurans (PCDD/Fs) and dioxin-like polychlorinated biphenyls (DL-PCBs), as well as the resulting soil contamination that might be caused by open burning of municipal solid waste. The emission factors of the waste residue, accounting for the ratio of waste burned, have also been characterized. The concentrations of PCDD/Fs and DL-PCBs in soil from Palembang were 61–310 pg-TEQ/g (dry weight) and 6.3–32 pg-TEQ/g, respectively. In Surabaya, very low levels of PCDD/Fs and DL-PCBs, ranging from 0.075 to 0.098 and 0.00032 to 0.095 pg-TEQ/g, respectively, were observed in soil for an open dumping site that included a top cover layer of soil above the compacted waste. The large difference in concentrations can be explained by the fact that open burning of waste is the source of PCDD/Fs and DL-PCBs. The emission factors for the residue for PCDD/Fs ranged from 27 to 140 pg-TEQ/g, and a sensitivity analysis found that the maximum emission factor to the residue could be 5600 pg-TEQ/g. Our results indicate that emissions of PCDD/Fs can be controlled by modifying the open dumping process to one that involves depositing soil layers on top of the compacted waste.  相似文献   

18.
粉煤灰综合利用研究进展   总被引:6,自引:0,他引:6  
介绍了粉煤灰的物理化学性质。综述了粉煤灰在建材制造、建筑工程、道路工程、农业、废水处理和催化反应中的应用现状以厦未来的应用前景。  相似文献   

19.
Air emissions and residual ash samples were collected and analyzed during experiments of open, uncontrolled combustion of electronic waste (e-waste), simulating practices associated with rudimentary e-waste recycling operations. Circuit boards and insulated wires were handled separately to simulate processes associated with metal recovery. The average emissions of polychlorinated dibenzodioxins and dibenzofurans (PCDD/PCDFs) were 92 ng toxic equivalency (TEQ)/kg [n = 2, relative standard deviation (RSD) = 98%] and 11 900 ng TEQ/kg (n = 3, RSD = 50%) of the initial mass of the circuit boards and insulated wire, respectively. The value for the insulated wire is about 100 times higher than that for backyard barrel burning of domestic waste. The emission concentrations of polybrominated dibenzodioxins and dibenzofurans (PBDD/PBDFs) from the combustion of circuit boards were 100 times higher than for their polychlorinated counterparts. Particulate matter (PM) sampling of the fly ash emissions indicated PM emission factors of approximately 15 and 17 g/kg of the initial mass for the circuit boards and insulated wire, respectively. Fly ash samples from both types of e-waste contained considerable amounts of several metallic elements and halogens; lead concentrations were more than 200 times the United States regulatory limits for municipal waste combustors and 20 times those for secondary lead smelters. Leaching tests of the residual bottom ash showed that lead concentrations exceeded U.S. Environmental Protection Agency landfill limits, designating this ash as a hazardous waste.  相似文献   

20.
After the deadly earthquake on May 12, 2008 in Wenchuan county of China, several different incineration approaches were used for medical waste disposal. This paper investigates the generation properties of polycyclic aromatic hydrocarbons (PAHs) during the incineration. Samples were collected from the bottom ash in an open burning slash site, surface soil at the open burning site, bottom ash from a simple incinerator, bottom ash generated from the municipal solid waste (MSW) incinerator used for medical waste disposal, and bottom ash and fly ash from an incinerator exclusively used for medical waste. The species of PAHs were analyzed, and the toxicity equivalency quantities (TEQs) of samples calculated. Analysis results indicate that the content of total PAHs in fly ash was 1.8 × 103 times higher than that in bottom ash, and that the strongly carcinogenic PAHs with four or more rings accumulated sensitively in fly ash. The test results of samples gathered from open burning site demonstrate that Acenaphthylene (ACY), Acenaphthene (ACE), Fluorene (FLU), Phenanthrene (PHE), Anthracene (ANT) and other PAHs were inclined to migrate into surrounding environment along air and surface watershed corridors, while 4- to 6-ring PAHs accumulated more likely in soil. Being consistent with other studies, it has also been confirmed that increases in both free oxygen molecules and combustion temperatures could promote the decomposition of polycyclic PAHs. In addition, without the influence of combustion conditions, there is a positive correlation between total PCDD/Fs and total PAHs, although no such relationship has been found for TEQ.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号