首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
Palm oil mill effluent (POME) is highly polluting wastewater generated from the palm oil milling process. Palm oil mill effluent was used as an electrolyte without any additive or pretreatment to perform electrocoagulation (EC) using electricity (direct current) ranging from 2 to 4 volts in the presence of aluminum electrodes with a reactor volume of 20 L. The production of hydrogen gas, removal of chemical oxygen demand (COD), and turbidity as a result of electrocoagulation of POME were determined. The results show that EC can reduce the COD and turbidity of POME by 57 and 62%, respectively, in addition to the 42% hydrogen production. Hydrogen production was also helpful to remove the lighter suspended solids toward the surface. The production of Al(OH)XHO at the aluminum electrode (anode) was responsible for the flocculation-coagulation process of suspended solids followed by sedimentation under gravity. The production of hydrogen gas from POME during EC was also compared with hydrogen gas production by electrolysis of tap water at pH 4 and tap water without pH adjustment under the same conditions. The main advantage of this study is to produce hydrogen gas while treating POME with EC to reduce COD and turbidity effectively.  相似文献   

2.
Batch electrocoagulation experiments were carried out to evaluate the removal of sulfate and COD from petroleum refinery wastewater using three types of electrodes: aluminum, stainless steel, and iron. The effects of current density, electrode arrangement, electrolysis time, initial pH, and temperature were investigated for two wastewater samples with different concentrations of COD and sulfate. The experimental results indicated that the utilization of aluminum, as anode and cathode, was by far the most efficient arrangement in the reduction of both the contaminants. The treatment process was found to be largely affected by the current density and the initial composition of the wastewater. Although electrocoagulation was found to be most effective at 25°C and a pH of 8, the influence of these two parameters on the removal rate was not significant. The results demonstrated the technical feasibility of electrocoagulation as a possible and reliable technique for the pretreatment of heavily contaminated petroleum refinery wastewater.  相似文献   

3.
Electrocoagulation with aluminum electrodes was used to treat the vegetable oil refinery wastewater (VORW) in a batch reactor. The effects of operating parameters such as pH, current density, PAC (poly aluminum chloride) dosage and Na(2)SO(4) dosage on the removal of organics and COD removal efficiency have been investigated. It has been shown that the removal efficiency of COD increased with the increasing applied current density and increasing PAC and Na(2)SO(4) dosage and the most effective removal capacity was achieved at the pH 7. The results indicate that electrocoagulation is very efficient and able to achieve 98.9% COD removal in 90 min at 35 mAcm(-2) with a specific electrical energy consumption of 42 kWh(kgCOD(removed))(-1). The effluent was very clear and its quality exceeded the direct discharge standard.  相似文献   

4.
Chemical, electrochemical and flow variables were optimized to examine the effectiveness of the electrocoagulation process for the removal of copper, lead and cadmium. The electrochemical process, which uses electrodes of commercial laminate steel, was applied to simulated wastewater containing 12 mg dm(-3) of copper, 4 mg dm(-3) of lead and 4 mg dm(-3) of cadmium. The optimum conditions for the process were identified as pH=7, flow rate=6.3 cm(3) min(-1) and a current density between 31 and 54 A m(-2). When the electrode geometric area and time of electrolysis reached critical values, the copper removal reached a maximum value of 80%. A linear relationship was identified between the current density and the mass of generated sludge. In addition, a linear relationship was found between specific energy consumption and current density. The results of this investigation provide important data for the development of an industrial-scale electrolytic reactor.  相似文献   

5.
Long-term consumption of water containing excessive fluoride can lead to fluorosis of the teeth and bones. Electrocoagulation (EC) is an electrochemical technique, in which a variety of unwanted dissolved particles and suspended matter can be effectively removed from an aqueous solution by electrolysis. Continuous flow experiments with monopolar aluminium electrodes for fluoride removal were undertaken to investigate the effects of the different parameters such as: current density (12.5-50A/m(2)), flow rate (150-400 mL/min), initial pH (4-8), and initial fluoride concentration (5-25mg/L). The highest treatment efficiency was obtained for the largest current and the removal efficiency was found to be dependent on the current density, the flow rate and the initial fluoride concentration when the final pH ranged between 6 and 8. The composition of the sludge produced was analysed using the X-ray diffraction (XRD) spectrum. The strong presence of the aluminium hydroxide [Al(OH)(3)] in the above pH range, which maximizes the formation of aluminium fluoride hydroxide complex [Al(n)F(m)(OH)(3n-m)], is the main reason for defluoridation by electrocoagulation. The results obtained showed that the continuous flow electrocoagulation technology is an effective process for defluoridation of potable water supplies and could also be utilized for the defluoridation of industrial wastewater.  相似文献   

6.
This study examined o-nitrophenol removal from aqueous solutions by electrochemical oxidation employing a modified electrode. The modified electrode was produced by electrodepositing lead oxide onto a titanium substrate. Following electrochemical oxidation of o-nitrophenol-containing solutions, the remaining o-nitrophenol concentration and chemical oxygen demand (COD) values were determined. The optimum parameters were current density of 40 mA cm(-2), pH of 2.47, 60 min of electrolysis time, 4 g L(-1) NaCl electrolyte solution and temperature of 30 degrees C. Under these optimum conditions of electrochemical degradation using a lead oxide/titanium modified electrode complete removal of o-nitrophenol and COD was achieved.  相似文献   

7.
脉冲电解处理餐饮废水的试验研究   总被引:5,自引:0,他引:5  
脉冲电解是废水电解处理技术发展的一个重要方向。本文用改装的直流、脉冲两用电源对餐饮废水做了对比处理研究。试验结果表明,脉冲电解的处理效果优于直流电解,在CODcr的去除率相近的情况下,电耗可降低5.5%。当脉冲频率为1.67KHz,水力修留时间为29min,电流为50mA时,电耗为0.222KWh/m^3,CODcr的去除率可以达到83.1%。  相似文献   

8.
Within a few years all domestic wastewater effluents in the United States will be subjected to a minimum of a properly operated primary and secondary treatment process. This implies a very high degree of removal of the more readily biologically degradable material as measured by the BOD test. This practice will to a large degree negate the value of the BOD test as a pollution parameter. Organic carbon appears to be a more suitable means for determining the strength of a wastewater or for controlling the operation of physical and chemical treatment processes. Studies were conducted to determine the effect of time of passage on the ratio of organic carbon to BOD, COD and carbohydrate. The ratio was found to vary with both time and the state of the sample. The carbon content was reduced to a lesser degree than the other parameters. Organic carbon content appears to correlate better with COD than with BOD. The efficiency of a chemical precipitation process can be determined on the basis of organic carbon removal.  相似文献   

9.
Eight small-scale municipal wastewater treatment plants were evaluated over a period of 19 months in the suburb of Las Rozas in Madrid (Spain). Four plants used compact extended aeration, two used conventional activated sludge, two used conventional extended aeration, one used a rotary biodisc reactor and the other used a peat bed reactor. The best results were obtained from the plants that used conventional technologies and the biodisc. Conventional activated sludge and extended aeration had higher removal efficiencies for ammonia, TSS, COD and BOD(5) and produced good quality final effluents for final disposal in accordance with the discharge standard. Empirical equations that correlated the concentration of dissolved oxygen in the effluents with the efficiencies of TSS, ammonia, COD and BOD(5) removals for all plants evaluated were obtained. The performance of the plants using compact extended aeration was affected more than those using conventional technologies or rotary biodisc when the capacity exceeded that of its initial design.  相似文献   

10.
三维电极电解硝基苯废水处理实验研究   总被引:4,自引:0,他引:4  
以涂膜活性炭-活性炭为填充粒子,对三维电极电解硝基苯废水进行了研究。通过实验探讨了投盐量、槽电压、主电极间距、反应时间及初始浓度对电解硝基苯废水的影响。结果表明,三维电极在电极间距为9mm、槽电压为20V、硫酸钠投加量为1.5g/L、pH值为6、电解时间为90min的条件下,硝基苯去除率可达90%以上。在三维电极电解作用下,硝基苯转化为可生化和低毒的苯胺,苯胺在三维电极电解作用下还可以得到进一步的降解。  相似文献   

11.
Wood processing effluents contain different types of phenolic compounds, from simple monomers to high molecular weight (MW) polyphenolic polymers, that can inhibit wastewater treatment. This work presents a comparative study of the methanogenic toxicity produced by three wood processing effluents (hardboard, fiberboard and BKME (kraft mill effluent)) using Pinus radiata, Eucalyptus and Tepa as feedstock (the last one being a native Chilean tree species). This study evaluates the influence of non-adapted granular and adapted flocculent sludge on forest industrial wastewater treatment as well as continuous anaerobic biodegradation of hardboard processing effluent using the upflow anaerobic sludge blanket (UASB). The adapted biomass (flocculent sludge) did not show any lag-phase signs. The 50% IC (the concentration causing 50% inhibition of methanogenic activity) was 4.3 g COD-effluent (chemical oxygen demand (COD)-of the effluent)/l and 2.8 g COD-effluent/l for the flocculent sludge and the granular sludge, respectively. The UASB system worked at low organic load rates (0.1-0.4 g COD/l d) with the COD removal ranging between 10 and 30%, and color removal did not occur under anaerobic conditions due to high MW. Indeed, the MW analysis indicates the presence of phenolic compounds over 25,000 Da in the anaerobic effluent.  相似文献   

12.
研究了在单独电解作用下及超声辐射.电解联合作用下,降解马拉硫磷农药废水的不同效果,详细探讨了电解时间、酸碱性、电压、电流及加入电解质的量等因素对结果的影响。实验结果表明,马拉硫磷农药废水在电解单独作用下,COD去除率可达到86.86%;在超声辐射-电解联合作用下,COD去除率可达到91.53%。  相似文献   

13.
This study focuses on a lab-scale rotating biological contactor (RBC) treating vegetable oil wastewater with high BOD and COD. The fabricated RBC was checked for efficiency in degrading polluted wastewater under different operating conditions. The maximum removal efficiencies for BOD and COD were 95.75% and 89%, respectively. This high removal percentage was obtained with 30% submergence of 10 discs rotating at 8 rpm. For the first time, bio-kinetic models were applied to the experimental results for vegetable oil wastewater. The best fit was obtained with the modified Stover-Kincannon and Grau model. The saturation constant (Ks) values were 1.872 and 3.024 g/L/d for BOD and COD, respectively, for the modified Stover-Kincannon and Grau model. For the Grau second-order model, the saturation constant was 1.416 and 3.744 g/L/d for BOD and COD, respectively. The predicted effluent BOD and COD values of the modified Stover–Kincannon model fitted almost exactly with the experimental values. This clearly predicts that this model can be best used to predict effluent BOD and COD concentration in a Rotating Biological contactor treating vegetable oil wastewater. The kinetic parameters determined in this study can be used to improve the design and operation of continuous mode RBC systems.  相似文献   

14.
The main objective of this paper was to perform a preliminary comparative study between chemical and electrochemical coagulation processes, both followed by flocculation and sedimentation of an effluent from an upflow anaerobic sludge blanket (UASB) reactor treating simulated wastewater from an unbleached Kraft pulp mill. The electrochemical treatment removed up to 67% (with aluminum electrodes) and 82% (with stainless-steel electrodes) of the remaining chemical oxygen demand (COD) and 84% (stainless steel) and 98% (aluminum) of the color in the wastewater. These efficiencies were achieved with an energy consumption ranging from 14 to 20 Wh l(-1). The coagulation-flocculation treatment with ferric chloride and aluminum sulfate removed up to 87% and 90% of COD and 94% and 98% of color, respectively. The addition of a high molecular weight cationic polymer enhanced both COD and color removal efficiencies. The two post-treatment processes proved to be technically feasible; however the economical feasibility could not be assessed since the experiments were performed with small reactors that could distort scale factors.  相似文献   

15.
Industrialization plays a major role in a nation's growth. However, with an increase in industrial activities, pollution levels are also increasing. Among all industries, the sugar‐processing industry is one that requires large amounts of water to process the sugar, and, consequently, it discharges large amounts of water as effluent. Highly polluted wastewater brings changes to the physicochemical characteristics of the surrounding environment. Iron compounds have had a significant impact when they are used in wastewater treatment in various applications, including when they are used to minimize the pollution levels in sugar industry wastewater (SIWW). To minimize the pollutant levels from SIWW, iron compounds have been key for uses in treatments involving chemical and electro‐oxidation. Two different methodologies of electrocoagulation and chemical coagulation have been used to treat SIWW. In electrocoagulation, an iron plate is used as an electrode material under specific operating conditions. Ferrous sulfate and ferric chloride have been used as chemical coagulants at various pH and mass loading levels. The use of iron metals shows an 82% reduction in chemical oxygen demand (COD) and an 84% reduction in color at the optimum condition of pH 6, an electrode distance of 20 millimeters, and a current density of 156 square centimeters. As a chemical coagulant, iron salt (ferrous sulfate) provides a reduction of 77% COD and a 91% reduction of color at pH 6 and a 40‐millimole mass loading. Electrochemical treatment using iron was found to be suitable to treat SIWW. The sludge generated after treatment can be burned or composted with the possible recovery of some of the treatment costs.  相似文献   

16.
Since the performance of algal treatment for pulp mill effluent decreases with increasing color intensity and AOX content, which mainly originate from the chlorine bleaching of Kraft pulp, the separated CEH bleaching effluent was pre-treated by both the conventional and the heterogeneous catalytic ozonation processes. An increase in the BOD(5)/COD ratio from 0.11 to 0.28 and 87% color abatement in terms of Pt-Co were achieved by catalytic ozonation, which had the best treatment performance. Biodegradability enhancement of the CEH effluent correlated well with a decrease in toxicity, high-molecular-weight-compound content, and AOX abatement. By the pre-treatment of the CEH bleaching effluent, the overall efficiencies of algal treatment of the combined pulp mill effluent in terms of the fractional removal of COD and color were increased from 76% and 53% to 86-90% and 96-99%, respectively. Effects of both the conventional and the catalytic ozonation pre-treatments on subsequent biological treatment were close to each other and they reduced the filling period of the Sequential Batch Reactor (SBR) cycle from 8 to 5 days.  相似文献   

17.
Color and chemical oxygen demand (COD) in bleach plant effluents are of concern. Acidified flyash can effectively remove both color and COD from caustic bleach plant effluents. Equally effective, but quicker and easier, is to acidify the effluent to approximately pH 1 and use untreated flyash. Based on maximum color removal, the required contact time is short, about 10 min, and the optimum ash dosage is that amount which raises the pH of the final effluent to about 5. Sufficient color removal is obtained to easily meet Maine's color regulations. Preliminary tests on samples of deionized water spiked with two arochlors of PCB showed high removal efficiency.The major cost of implementing and operating the cleanup procedure will be the cost of the required acid. This might be minimized by using some of the acidic (chlorine) effluent to lower the pH of the caustic effluent. This will, however, lead to less color reduction, and an unknown effect on the COD.  相似文献   

18.
微生物菌剂在酿酒废水处理中的应用研究   总被引:6,自引:1,他引:5  
采用厌氧-好氧工艺,结合微生物菌剂对酿酒废水进行了处理研究。进水CODCr浓度可达到8,456.3-22,442.0mg/L,BOD55,040.0-9.557.1mg/L,pH3-4,可不调pH,采用微生物菌剂接种可启动厌氧反应器,COD有机负荷最高达到10.2gCOD/Ld,COD去除率稳定在91-95%,BOD去除率90-94%,出水pH6.6-7.1,出水CODCr在2,000mg/L以下,BOD5800mg/L以下。厌氧污泥可全部颗粒化。好氧处理系统中接种微生物菌剂,曝气10-12小时,可保证出水中CODCr在230mg/L以下,甚至直接达到国家一级排放标准。微生物菌剂的应用是取得该处理效果的关键。  相似文献   

19.
采用混凝沉淀一厌氧水解酸化一催化铁内电解(即Cu/Fe体系)一好氧组合工艺处理焦化废水,研究了催化铁内电解法用于焦化废水的预处理时,对焦化废水的COD、色度、总磷的去除率。结果表明,催化铁用于焦化废水的预处理,可以提高废水的可生化性,使好氧处理的COD去除率提高,达到80%-90%;催化铁对焦化废水有较好的脱色效果,色度去除率为77.7%-89.3%;催化铁能够去除部分总磷,但是由于微生物生长需要,需在厌氧段补充磷。试验证明,催化铁内电解法是一种有效的焦化废水预处理工艺。  相似文献   

20.
Resting (living) bio-sludge from a domestic wastewater treatment plant was used as an adsorbent of both direct dyes and organic matter in a sequencing batch reactor (SBR) system. The dye adsorption capacity of the bio-sludge was not increased by acclimatization with direct dyes. The adsorption of Direct Red 23 and Direct Blue 201 onto the bio-sludge was almost the same. The resting bio-sludge showed higher adsorption capacity than the autoclaved bio-sludge. The resting bio-sludge that was acclimatized with synthetic textile wastewater (STWW) without direct dyes showed the highest Direct Blue 201, COD, and BOD(5) removal capacities of 16.1+/-0.4, 453+/-7, and 293+/-9 mg/g of bio-sludge, respectively. After reuse, the dye adsorption ability of deteriorated bio-sludge was recovered by washing with 0.1% sodium dodecyl sulfate (SDS) solution. The direct dyes in the STWW were also easily removed by a GAC-SBR system. The dye removal efficiencies were higher than 80%, even when the system was operated under a high organic loading of 0.36kgBOD(5)/m(3)-d. The GAC-SBR system, however, showed a low direct dye removal efficiency of only 57+/-2.1% with raw textile wastewater (TWW) even though the system was operated with an organic loading of only 0.083kgBOD(5)/m(3)-d. The dyes, COD, BOD(5), and total kjeldalh nitrogen removal efficiencies increased up to 76.0+/-2.8%, 86.2+/-0.5%, 84.2+/-0.7%, and 68.2+/-2.1%, respectively, when 0.89 g/L glucose (organic loading of 0.17kgBOD(5)/m(3)-d) was supplemented into the TWW.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号