The objective of this study is to investigate the potential process for the removal of carbon dioxide (CO2) from flue gas using fundamental membrane contactor, which is a membrane gas absorption (MGA) system. The experiments consisted of microporous polyvinylidenefluoride (PVDF) flat sheet membrane with 0.1 μm (as module I) and 0.45 μm (as module II) pore size. 2-Amino-2-methyl-1-propanol (AMP) solution was employed as the liquid absorbent. The effect of AMP concentration was studied with variation in the range 1–5 M. In addition, the experiments were carried out with 10%, 20%, 30% and 40% gas ratio of CO2 to N2 and pure CO2 as well. Through contact angle measurement, membranes for module I and module II were obtained with CA values of around 130.25° and 127.77°, respectively. The mass transfer coefficients for module II are lower than those of module I for 1–5 M of AMP. Furthermore, the increase in CO2 concentration in the feed gas stream enhanced the CO2 flux as the driving force of the system was increased in sequence from 1 M to 5 M of AMP. However, after the particular percentage (40%) of CO2 inlet concentration, the CO2 fluxes seem saturated. The combination of AMP as liquid absorbent and PVDF microporous membrane in MGA system has shown the potential to remove the CO2 from flue gas. In addition, the higher AMP concentration gave higher mass transfer coefficient at low liquid flow rates.  相似文献   

2.
The behavior of natural carbon dioxide (CO2) droplets (8–10 mm in diameter) were observed in a seafloor hydrothermal system at the Okinawa Trough. The natural CO2 droplet contain 95–98% of CO2, 2–3% of H2S, and other gas species. The ascending CO2 droplets were tracked by a remotely operated vehicle (ROV), and depth, temperature, salinity, pH and partial pressure of CO2 (pCO2) in seawater near the CO2 droplets were measured during droplet ascent by a conductivity-temperature-depth sensor (CTD) and in situ pH/pCO2 sensor. The visual images of the rising CO2 droplets were recorded with a high definition television camera on the ROV. A mapping survey (400 m × 400 m; 4 horizontal layers) revealed a dominant distribution of low pH area over the natural CO2 venting site. The size and rise rate of CO2 droplets decreased during their ascent in the water column from depths of 1424 to 679 m (a tracking interval of 745 m). The CO2 droplets dissolved gradually to become small flakes of CO2 hydrate while rising, and these ascending flakes were found to disappear at 679 m depth. Although a pH as low as 5 was detected just above the liquid CO2 venting site on the seafloor, no detectable pH depression in the water column ambient to the rising CO2 droplets was observed. The results of the pH mapping survey showed only localized pH depression over the CO2 venting site.  相似文献   

3.
Ash deposition is still an unresolved problem when retrofitting existing air-fired coal power plants to oxy-fuel combustion. Experimental data are quite necessary for mechanism validation and model development. This work was designed to obtain laboratory combustor data on ash and deposits from oxy-coal combustion, and to explore the effects of oxy-firing on their formation. Two bituminous coals (Utah coal and Illinois coal) and one sub-bituminous coal (PRB coal) were burned on a down-fired combustor under both oxy- and air-firing. Two oxy-fired cases, i.e., 27 vol% O2/73 vol% CO2 and 32 vol% O2/68 vol% CO2, were selected to match the radiation flux and the adiabatic flame temperature of air combustion, respectively. Once-through CO2 was used to simulate fully cleaned recycled flue gas. The flue gas excess oxygen was fixed at 3 vol%. For each case, both size-segregated fly ash and bulk fly ash samples were obtained. Simultaneously, ash deposits were collected on an especially designed un-cooled deposition probe. Ash particle size distributions and chemical composition of all samples were characterized. Data showed that oxy-firing had insignificant impacts on the tri-modal ash particle size distributions and composition size distributions in the size range studied. Bulk ash compositions also showed no significant differences between oxy- and air-firing, except for slightly higher sulfur contents in some oxy-fired ashes. The oxy-fired deposits were thicker than those from air-firing, suggesting enhanced ash deposition rates in oxy-firing. Oxy-firing also had apparent impacts on the deposit composition, especially for those components (e.g., CaO, Fe2O3, SO3, etc.) that could contribute significantly to ash deposition. Based on these results, aerodynamic changes in gas flow and changes in combustion temperature seemed more important than chemical changes of ash particles in determining deposit behavior during oxy-coal combustion.  相似文献   

4.
Basic research on the corrosive effect of flue gases has been performed at the BAM Federal Institute for Materials Research and Testing (Germany). Conditions at both high and low temperatures were simulated in specially designed experiments. Carburization occured in flue gases with high CO2 content and temperatures higher than 500 °C. In SO2 containing flue gases sulphur was detected in the oxide scale. At lower temperatures no corrosion was observed when gases with low humidity were investigated. Humidity higher than 1500 ppm was corrosive and all steels with Cr contents lower than 12% revealed corroded surfaces. At low temperatures below 10 °C a mixture of sulphuric and nitric acid condensed on metal surfaces. Acid condensation caused severe corrosion. Humidity, CO2, O2, and SO2 contents are the important factors determining corrosion. Below 300 °C acid condensation is the primary reason for corrosion. Low humidity and low temperatures are conditions which can be expected in the CO2 separation and treatment process. This work includes major conditions of the flue gas and CO2 stream in CCS plants and CCS technology.  相似文献   

5.
A post-combustion CO2 capture process intended for offshore operations has been designed and optimised for integration with a natural gas-fired power plant on board a floating structure developed by the Norway-based company Sevan Marine ASA—designated Sevan GTW (gas-to-wire). The concept is constrained by the structure of the floater carrying a SIEMENS modular power system rated at 450 MWe, with a capture rate of 90% and CO2 compression (1.47 Mtpa) for pipeline pressure at 12 MPa. A net efficiency of 45% (based on a lower heating value) is estimated for the system with CO2 capture, thus suggesting that the post-combustion CO2 capture system is accountable for a fuel penalty of nine percentage points.The rationale behind the technology selection is the urgency of replacing the dispersed aero-derivative gas turbines which power the offshore oil and gas production units in Norwegian waters with near-zero emission power.As (inherently) fresh water usually constitutes a limiting factor in sea operations, efforts are made to obtain a neutral water balance to obtain an optimal design. This is primarily achieved by controlling the cleaned flue gas temperature at the top of the absorber column.  相似文献   

6.
In order to evaluate the risk of hydrate formation in CO2 transport one has to be able to predict the water content in the fluid phase in equilibrium with the CO2-hydrate. A literature review has identified some knowledge gaps, for example, there are no results available at temperatures lower than 243.15 K (?30 °C); and none of the models found in literature predicts the water content with high accuracy. A model based on equality of water fugacity in fluid and hydrate phase is presented here and used for the predictions of water content in equilibrium with hydrates. Although this model gives better accuracy in the overall temperature and pressure ranges of measurements than the models found in the literature, it is not accurate enough to satisfy the requirements of CO2 transport. The simulation results also show that it is possible to form hydrate at low water content, such as xw = 50 vppm, if temperature is low enough. In order to verify the results and improve the model accuracy further, more experimental data in a larger temperature and pressure region are required.  相似文献   

7.
Calcium looping (CaL) is a promising post-combustion CO2 capture technology which is carried out in a dual fluidized bed (DFB) system with continuous looping of CaO, the CO2 carrier, between two beds. The system consists of a carbonator, where flue gas CO2 is adsorbed by CaO and a regenerator, where captured CO2 is released. The CO2-rich regenerator flue gas can be sequestered after gas processing and compression. A parametric study was conducted on the 10 kWth DFB facility at the University of Stuttgart, which consists of a bubbling fluidized bed carbonator and a riser regenerator. The effect of the following parameters on CO2 capture efficiency was investigated: carbonator space time, carbonator temperature and calcium looping ratio. The active space time in the carbonator, which is a function of the space time and the calcium looping ratio, was found to strongly correlate with the CO2 capture efficiency. BET and BJH techniques provided surface area and pore volume distribution data, respectively, for collected sorbent samples. The rate of sorbent attrition was found to be 2 wt.%/h which is below the expected sorbent make-up rate required to maintain sufficient sorbent activity. Steady-state CO2 capture efficiencies greater than 90% were achieved for different combinations of operational parameters. Moreover, the experimental results obtained were briefly compared with results derived from reactor modeling studies. Finally, the implications of the experimental results with respect to commercialization of the CaL process have been assessed.  相似文献   

8.
Post-combustion CO2 capture and storage (CCS) presents a promising strategy to capture, compress, transport and store CO2 from a high volume–low pressure flue gas stream emitted from a fossil fuel-fired power plant. This work undertakes the simulation of CO2 capture and compression integration into an 800 MWe supercritical coal-fired power plant using chemical process simulators. The focus is not only on the simulation of full load of flue gas stream into the CO2 capture and compression, but also, on the impact of a partial load. The result reveals that the energy penalty of a low capture efficiency, for example, at 50% capture efficiency with 10% flue gas load is higher than for 90% flue gas load at the equivalent capture efficiency by about 440 kWhe/tonne CO2. The study also addresses the effect of CO2 capture performance by different coal ranks. It is found that lignite pulverized coal (PC)-fired power plant has a higher energy requirement than subbituminous and bituminous PC-fired power plants by 40.1 and 98.6 MWe, respectively. In addition to the investigation of energy requirement, other significant parameters including energy penalty, plant efficiency, amine flow rate and extracted steam flow rate, are also presented. The study reveals that operating at partial load, for example at half load with 90% CO2 capture efficiency, as compared with full load, reduces the energy penalty, plant efficiency drop, amine flow rate and extracted steam flow rate by 9.9%, 24.4%, 50.0% and 49.9%, respectively. In addition, the effect of steam extracted from different locations from a series of steam turbine with the objective to achieve the lowest possible energy penalty is evaluated. The simulation shows that a low extracted steam pressure from a series of steam turbines, for example at 300 kPa, minimizes the energy penalty by up to 25.3%.  相似文献   

9.
The capture of CO2 from a hot stove gas in steel making process containing 30 vol% CO2 by chemical absorption in a rotating packed bed (RPB) was studied. The RPB had an inner diameter of 7.6 cm, an outer diameter of 16 cm, and a height of 2 cm. The aqueous solutions containing 30 wt% of single and mixed monoethanolamine (MEA), 2-(2-aminoethylamino)ethanol (AEEA), and piperazine (PZ) were used. The CO2 capture efficiency was found to increase with increasing temperature in a range of 303–333 K. It was also found to be more dependent on gas and liquid flow rates but less dependent on rotating speed when the speed was higher than 700 rpm. The obtained results indicated that the mixed alkanolamine solutions containing PZ were more effective than the single alkanolamine solutions. This was attributed to the highest reaction rate of PZ with CO2. A higher portion of PZ in the mixture was more favorable to CO2 capture. The highest gas flow rates allowed to achieve a desired CO2 capture efficiency and the correspondent height of transfer unit (HTU) were determined at different aqueous solution flow rates. Because all the 30 wt% single and mixed alkanolamine solutions could result in a HTU less than 5.0 cm at a liquid flow rate of 100 mL/min, chemical absorption in a RPB instead of a packed bed adsorber is therefore suggested to capture CO2 from the flue gases in steel making processes.  相似文献   

10.
Capture and storage of CO2 from fossil fuel fired power plants is drawing increasing interest as a potential method for the control of greenhouse gas emissions. An optimization and technical parameter study for a CO2 capture process from flue gas of a 600 MWe bituminous coal fired power plant, based on absorption/desorption process with MEA solutions, using ASPEN Plus with the RADFRAC subroutine, was performed. This optimization aimed to reduce the energy requirement for solvent regeneration, by investigating the effects of CO2 removal percentage, MEA concentration, lean solvent loading, stripper operating pressure and lean solvent temperature.Major energy savings can be realized by optimizing the lean solvent loading, the amine solvent concentration as well as the stripper operating pressure. A minimum thermal energy requirement was found at a lean MEA loading of 0.3, using a 40 wt.% MEA solution and a stripper operating pressure of 210 kPa, resulting in a thermal energy requirement of 3.0 GJ/ton CO2, which is 23% lower than the base case of 3.9 GJ/ton CO2. Although the solvent process conditions might not be realisable for MEA due to constraints imposed by corrosion and solvent degradation, the results show that a parametric study will point towards possibilities for process optimisation.  相似文献   

11.
We sketch four possible pathways how carbon dioxide capture and storage (CCS) (r)evolution may occur in the Netherlands, after which the implications in terms of CO2 stored and avoided, costs and infrastructural requirements are quantified. CCS may play a significant role in decarbonising the Dutch energy and industrial sector, which currently emits nearly 100 Mt CO2/year. We found that 15 Mt CO2 could be avoided annually by 2020, provided some of the larger gas fields that become available the coming decade could be used for CO2 storage. Halfway this century, the mitigation potential of CCS in the power sector, industry and transport fuel production is estimated at maximally 80–110 Mt CO2/year, of which 60–80 Mt CO2/year may be avoided at costs between 15 and 40 €/t CO2, including transport and storage. Avoiding 30–60 Mt CO2/year by means of CCS is considered realistic given the storage potential represented by Dutch gas fields, although it requires planning to assure that domestic storage capacity could be used for CO2 storage. In an aggressive climate policy, avoiding another 50 Mt CO2/year may be possible provided that nearly all capture opportunities that occur are taken. Storing such large amounts of CO2 would only be possible if the Groningen gas field or large reservoirs in the British or Norwegian part of the North Sea will become available.  相似文献   

12.
Significant differences exist in the flue gas composition in hot recycle Oxyfuel conditions as e.g. the high CO2 partial pressure (>90 vol%, dry), the very high SO2 concentration and the high water content (approx. 30 vol%). Therefore certain design and operation criteria have to be observed for the flue gas desulphurization with forced oxidation under Oxyfuel combustion conditions. Several performance tests have been executed at the 30 MWth Oxyfuel pilot plant in Schwarze Pumpe to evaluate the main performance parameters and to assess the influence of the major operation parameters. The results show that there are no fundamental problems for the operation of the flue gas desulphurization unit under Oxyfuel combustion conditions. High removal rates could be reached and no negative impact of the high CO2 partial pressure was observed under the tested operating conditions. No major differences in the gypsum quality have been observed between air firing and Oxyfuel conditions.  相似文献   

13.
The oxyfuel process is one of the most promising options to capture CO2 from coal fired power plants. The combustion takes place in an atmosphere of almost pure oxygen, delivered from an air separation unit (ASU), and recirculated flue gas. This provides a flue gas containing 80–90 vol% CO2 on a dry basis. Impurities are caused by the purity of the oxygen from the ASU, the combustion process and air ingress. Via liquefaction a CO2 stream with purity in the range from 85 to 99.5 vol% can be separated and stored geologically. Impurities like O2, NOX, SOX, and CO may negatively influence the transport infrastructure or the geological storage site by causing geochemical reactions. Therefore the maximum acceptable concentrations of the impurities in the separated CO2 stream must be defined regarding the requirements from transportation and storage. The main objective of the research project COORAL therefore is to define the required CO2 purity for capture and storage.  相似文献   

14.
Oxy-fuel combustion systems have been under development to reduce CO2 emissions from coal-fired power plants. In oxy-fuel combustion system, Hg in the flue gas causes corrosion in CO2 purification and compression units. Also, SO3 in the flue gas corrodes the equipment and ducts of oxy-fuel combustion system. Therefore, Hg and SO3 need to be removed.Babcock-Hitachi conducted tests using a 1.5 MWth Combustion & Air Quality Control System (AQCS) test facility which consists of oxygen supply unit, furnace, Selective Catalytic Reduction (SCR) catalyst, Clean Energy Recuperator (CER), Dry Electrostatic Precipitator (DESP), flue gas recirculation system, Wet Flue Gas Desulfurization (WFGD), and CO2 Compression and Purification Unit (CPU). In both cases of air and oxy-fuel combustion, the Hg removal across the DESP could be improved, and SO3 concentration at the DESP outlet could be reduced to less than 1 ppm by installing a CER upstream of the DESP and reducing the gas temperature at the DESP inlet. Hg was not dissolved in the drain recovered from CO2 compressor, and may be adsorbed at an inner part of CO2 compressor. This indicated that Hg needs to be removed at a location upstream of the CO2 compressor to prevent corrosion of the compressor.  相似文献   

15.
Chemical-Looping Combustion (CLC) is an emerging technology for CO2 capture because separation of this gas from the other flue gas components is inherent to the process and thus no energy is expended for the separation. Natural or refinery gas can be used as gaseous fuels and they may contain different amounts of light hydrocarbons. This paper presents the combustion results obtained with a Cu-based oxygen carrier using mixtures of CH4 and light hydrocarbons (LHC) (C2H6 and C3H8) as fuel. The effect on combustion efficiency of the fuel reactor temperature, solid circulation flow rate and gas composition was studied in a continuous CLC plant (500 Wth). Full combustions were reached at 1073 and 1153 K working at oxygen to fuel ratios, ? higher than 1.5 and 1.2 respectively. Unburnt hydrocarbons were never detected at any experimental conditions at the fuel reactor outlet. Carbon formation can be avoided working at 1153 K or at ? values higher than 1.5 at 1073 K. After 30 h of continuous operation, the oxygen carrier exhibited an adequate behavior regarding attrition and agglomeration. It can be concluded that no special measures should be taken in a CLC process with Cu-based OC with respect to the presence of LHC in the fuel gas.  相似文献   

16.
Studies of the kinetics of sulfur dioxide (SO2)- and oxygen (O2)-induced degradation of aqueous monoethanolamine (MEA) during the absorption of carbon dioxide (CO2) from flue gases derived from coal- or natural gas-fired power plants were conducted as a function of temperature and the liquid phase concentrations of MEA, O2, SO2 and CO2. The kinetic data were based on the initial rate which shows the propensity for amine degradation and obtained under a range of conditions typical of the CO2 absorption process (3–7 kmol/m3 MEA, 6% O2, 0–196 ppm SO2, 0–0.55 CO2 loading, and 328–393 K temperature). The results showed that an increase in temperature and the concentrations of MEA, O2 and SO2 resulted in a higher MEA degradation rate. An increase in CO2 concentration gave the opposite effect. A semi-empirical model based on the initial rate, ?rMEA = {6.74 × 109 e?(29,403/RT)[MEA]0.02([O]2.91 + [SO2]3.52)}/{1 + 1.18[CO2]0.18} was developed to fit the experimental data. With the higher order of reaction, SO2 has a higher propensity to cause MEA to degrade than O2. Unlike previous models, this model shows an improvement in that any of the parameters (i.e. O2, SO2, and CO2) can be removed without affecting the usability of the model.  相似文献   

17.
Chemical-Looping Combustion (CLC) is an emerging technology for CO2 capture because separation of this gas from the other flue gas components is inherent to the process and thus no energy is expended for the separation. Natural or refinery gas can be used as gaseous fuels and they may contain different amounts of sulphur compounds, such as H2S and COS. This paper presents the combustion results obtained with a Cu-based oxygen carrier using mixtures of CH4 and H2S as fuel. The influence of H2S concentration on the gas product distribution and combustion efficiency, sulphur splitting between the fuel reactor (FR) and the air reactor (AR), oxygen carrier deactivation and material agglomeration was investigated in a continuous CLC plant (500 Wth). The oxygen carrier to fuel ratio, ?, was the main operating parameter affecting the CLC system. Complete fuel combustion were reached at 1073 K working at ? values ≥1.5. The presence of H2S did not produce a decrease in the combustion efficiency even when working with a fuel containing 1300 vppm H2S. At these conditions, the great majority of the sulphur fed into the system was released in the gas outlet of the FR as SO2, affecting to the quality of the CO2 produced. Formation of copper sulphide, Cu2S, and the subsequent reactivity loss was only detected working at low values of ?  1.5, although this fact did not produce any agglomeration problem in the fluidized beds. In addition, the oxygen carrier was fully regenerated in a H2S-free environment. It can be concluded that Cu-based oxygen carriers are adequate materials to be used in a CLC process using fuels containing H2S although quality of the CO2 produced is affected.  相似文献   

18.
Using a combination of experimental (petrophysical and mineralogical) methods, the effects of high-pressure CO2 exposure on fluid transport properties and mineralogical composition of two pelitic caprocks, a limestone and a clay-rich marl lithotype have been studied. Single and multiphase permeability tests, gas breakthrough and diffusion experiments were conducted under in situ p/T conditions on cylindrical plugs (28.5 mm diameter, 10–20 mm thickness).The capillary CO2 sealing efficiency of the initially water-saturated sample plugs was found to decrease in repetitive gas breakthrough experiments on the same sample from 0.74 to 0.41 MPa for the limestone and from 0.64 to 0.43 MPa for the marl. Helium breakthrough experiments before and after the CO2 tests showed a decrease in capillary threshold (snap-off) pressure from 1.81 to 0.62 MPa for the limestone.Repetitive CO2 diffusion experiments on the marlstone revealed an increase in the effective diffusion coefficient from 7.8 × 10?11 to 1.2 × 10?10 m2.Single-phase (water) permeability coefficients derived from steady-state permeability tests ranged between 7 and 56 nano-Darcy and showed a consistent increase after each CO2 test cycle. Effective gas permeabilities were generally one order of magnitude lower than water permeabilities and exhibit the same trend. XRD measurements performed before and after exposure to CO2 did not reveal any distinct change in the mineral composition for both samples. Similarly, no significant changes were observed in specific surface areas (determined by BET) and pore-size distributions (determined by mercury injection porosimetry). High-pressure CO2 sorption experiments on powdered samples revealed significant CO2 sorption capacities of 0.27 and 0.14 mmol/g for the marlstone and the limestone, respectively.The changes in transport parameters in the absence of detectable mineral alterations may be explained by carbonate dissolution and further precipitation along a pH profile across the sample plug which would not be subject to quantitative mineral alteration.  相似文献   

19.
A novel CO2 separation concept is described wherein the enzyme carbonic anhydrase (CA) is used to increase the overall rate of CO2 absorption after which hydrated CO2 reacts with regenerable amine-bearing polyacrylamide buffering beads (PABB). Following saturation of the material's immobilized tertiary amines, CA-bearing carrier water is separated and recycled to the absorption stage while CO2-loaded material is thermally regenerated. Process application of this concept would involve operation of two or more columns in parallel with thermal regeneration with low-pressure steam taking place after the capacity of a column of amine-bearing polymeric material was exceeded. PABB CO2-bearing capacity was evaluated by thermogravimetric analysis (TGA) for beads of three acrylamido buffering monomer ingredient concentrations: 0 mol/kg bead, 0.857 mol/kg bead, and 2 mol/kg bead. TGA results demonstrate that CO2-bearing capacity increases with increasing PABB buffering concentration and that up to 78% of the theoretical CO2-bearing capacity was realized in prepared PABB samples (0.857 mol/kg recipe). The highest observed CO2-bearing capacity of PABB was 1.37 mol of CO2 per kg dry bead. TGA was also used to assess the regenerability of CO2-loaded PABB. Preliminary results suggest that CO2 is partially driven from PABB samples at temperatures as low as 55 °C, with complete regeneration occurring at 100 °C. Other physical characteristics of PABB are discussed. In addition, the effectiveness of bovine carbonic anhydrase for the catalysis of CO2 dissolution is evaluated. Potential benefits and drawbacks of the proposed process are discussed.  相似文献   

20.
A laboratory-scale reactor system was built and operated to demonstrate the feasibility of catalytically reacting carbon dioxide (CO2) with renewably-generated hydrogen (H2) to produce methane (CH4) according to the Sabatier reaction: CO2 + 4H2  CH4 + 2H2O. A cylindrical reaction vessel packed with a commercial methanation catalyst (Haldor Topsøe PK-7R) was used. Renewable H2 produced by electrolysis of water (from solar- and wind-generated electricity) was fed into the reactor along with a custom blend of 2% CO2 in N2, meant to represent a synthetic exhaust mixture. Reaction conditions of temperature, flow rates, and gas mixing ratios were varied to determine optimum performance. The extent of reaction was monitored by real-time measurement of CO2 and CH4. Maximum conversion of CO2 occurred at 300–350 °C. Approximately 60% conversion of CO2 was realized at a space velocity of about 10,000 h?1 with a molar ratio of H2/CO2 of 4/1. Somewhat higher total CO2 conversion was possible by increasing the H2/CO2 ratio, but the most efficient use of available H2 occurs at a lower H2/CO2 ratio.  相似文献   