首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The present study outlines applications of an enzyme-linked immunosorbent assay (ELISA) for the analysis of clenbuterol residues. Antisera were raised from rabbits immunized with diazotized clenbuterol-bovine serum albumin (BSA) conjugate. The assay was specific to clenbuterol with a half-maximum inhibition concentration (IC(50)) of 1.8 ng/mL and 2.5 ng/mL in blank swine urine and phosphate buffer solution, respectively. The assay had high cross-reactivity (86%) with mabuterol, but low with other adrenergic agonists and antagonists. The average recovery of clenbuterol, as measured with the ELISA, ranged from 90% to 112% in swine urine samples and from 86% to 95% in feeds, respectively. This new assay was compared with commercial ELISA test kits. An excellent correlation (r(2) = 0.98) between the two methods and satisfactory recoveries suggest that the new assay can be suitable for the determination of clenbuterol residues in real samples. The assay was used to analyze clenbuterol residues in 103 swine urine samples and 68 feed samples collected from northern China. Approximately 50% of the urine samples and 25% of the feed samples analyzed were found positive (concentration of clenbuterol > or = 1 ppb). The results indicate that clenbuterol was misused in some of the areas surveyed.  相似文献   

2.
A heterologous indirect enzyme-linked immunosorbent assay (ELISA) was developed, which was based on monoclonal antibody (Mab) to determine parathion residue in agricultural and environmental samples. Eight Mabs were produced by introducing the heterologous indirect ELISA into the screening procedure. It was shown that these Mabs had more broad-reactivity with twenty competitors than that of 5H7 (Mab produced by homologous screening). So it became much easier using these new Mabs to develop heterologous immunoassays. In addition, all the developed heterologous ELISAs could be used to determine parathion residue in semiquantitative or quantitative level, and their detection limitation (LOD) was around 2 ng/mL. Compared with the previous heterologous ELISA (hapten 11/5H7) with IC50 of 13.3 ng/mL, a better heterologous ELISA (hapten 11/1E1) was obtained with IC50 of 3.8 ng/mL, which improved the sensitivity 3.5 times. Finally, the latter was applied to parathion residue determination in spiked agricultural and environmental samples without extraction or cleanup. The average recoveries of parathion added to water, soil, cucumber, Chinese cabbage and carrot were between 80.4 % and 111.8 %. The LOD for water and soil samples was 5 ng/mL, and the LOD for cucumber, rice and corn samples was 10 ng/mL.  相似文献   

3.
A sensitive biotin–streptavidin‐amplified enzyme‐linked immunosorbent assay (BA‐ELISA) method was developed for detecting non‐steroidal anti‐inflammatory drug ketoprofen. Compared with traditional ELISA method, the sensitivity of proposed immunoassay was enhanced by the biotin–streptavidin system. Under the optimal condition, the median inhibitory concentration (IC50) was 0.25 ng mL?1, with minor cross‐reactivity to a number of structural analogs. This developed assay was successfully applied to detect the ketoprofen residues in different fish samples, and good recoveries (72.6–105.5%) were obtained. The results indicated that this immunoassay method could specifically detect trace ketoprofen residues and could be widely used for routine monitoring of food samples.  相似文献   

4.
A monoclonal antibody-based competitive antibody-coated enzyme-linked immunosorbent assay (ELISA) was developed and optimized for determining chlorpyrifos residue in agricultural products. The IC50 and IC10 of this ELISA were 3.3 ng/mL and 0.1 ng/mL respectively. The average recoveries in six agricultural products were between 79.5% and 118.0%, with the intra-assay coefficient of variation being less than 8 %. The limit of detection for all tested products was 30 ng/g. To the best of our knowledge, this assay has the best specificity among all the published research on ELISAs for chlorpyrifos.  相似文献   

5.
Diethyl (carboxymethyl) phosphonate (DECP) was used as the hapten to develop an indirect competitive enzyme-linked immunosorbent assay (IC-ELISA) for detecting organophosphorus pesticides (OPs). Conjugator of DECP with bovin serum albumin (BSA) was used as the immunogen for producing the polyclonal antibodies (PcAbs). Three antisera were obtained after the immune procedure. Characterization studies of the PcAbs indicated that the titer of antiserum-1 was highest in 3 antisera, and antiserum-1 had high affinity and specificity to the parathion, dichlorvos and pirimiphos. The IC-ELISA showed an IC50 of 0.428 μ g/mL with a detection limit of 0.0125 μ g/mL to parathion. The assay also indicated that the IC50 values of pirimiphos and dichlorvos were 0.331 μ g/mL and 1.25 μ g/mL respectively, and the detection limits of pirimiphos and dichlorvos were 0.0116 μ g/mL and 0.048 μ g/mL respectively. Recoveries of parathion, pirimiphos and dichlorvos spiked into water samples ranged from 90% to 160%. The results indicated that the ELISA could be a convenient and supplemental analytical tool for monitoring OPs residues in environmental water samples.  相似文献   

6.
This study was undertaken to develop and validate direct competitive ELISA for the determination of chloramphenicol residues in bovine milk. Antisera and an enzyme-tracer for chloramphenicol were prepared and used to develop an ELISA with inhibition concentrations, IC20 and IC50, of 0.09 and 0.44 ng mL?1, respectively. Milk samples were spiked with standards equivalent to 0, 0.2, 0.3, 0.5, 1.0 &; 1.5 ng mL?1 and extracted in methanol. The mean recoveries were found to be 73–100% with coefficient of variance 7–11%. The decision limit (CCα) and detection capability (CCβ) were calculated as 0.10 and 0.12 ng mL?1, respectively. The results were found comparable with the commercial ELISA, having recoveries of 87 to 100%, CCα 0.09 ng mL?1 and CCβ 0.12 ng mL?1. As per Commission Decision 2002/657/EC, in-house ELISA was further validated by using LC-MS/MS. Mass spectral acquisition was done by using electrospray ionization in the negative ion mode applying single reaction monitoring of the diagnostic transition reaction for CAP (m/z 152, 194 and 257). The calibration curve showed good linearity in concentrations from 0.025 to 1.6 ng mL?1 with correction coefficient 0.9902. The mean recoveries were found to be 88 to 100%. The CCα was calculated as 0.057 ng mL?1 and CCβ 0.10 ng mL?1. Since CCα and CCβ are less than half of the MRPL (0.15 ng mL?1), the test was found suitable for screening and quantification of CAP residues in bovine milk samples. Results of surveillance studies indicated that out of 31 analyzed milk samples, 12.9% samples were found with CAP residues but only 3.2% samples were declared positive with maximum concentration 0.31 ng mL?1, slightly above the MRPL.  相似文献   

7.
A monoclonal antibody-based competitive antibody-coated enzyme-linked immunosorbent assay (ELISA) was developed and optimized for determining chlorpyrifos residue in agricultural products. The IC(50) and IC(10) of this ELISA were 3.3 ng/mL and 0.1 ng/mL respectively. The average recoveries in six agricultural products were between 79.5% and 118.0%, with the intra-assay coefficient of variation being less than 8 %. The limit of detection for all tested products was 30 ng/g. To the best of our knowledge, this assay has the best specificity among all the published research on ELISAs for chlorpyrifos.  相似文献   

8.
Diethyl (carboxymethyl) phosphonate (DECP) was used as the hapten to develop an indirect competitive enzyme-linked immunosorbent assay (IC-ELISA) for detecting organophosphorus pesticides (OPs). Conjugator of DECP with bovin serum albumin (BSA) was used as the immunogen for producing the polyclonal antibodies (PcAbs). Three antisera were obtained after the immune procedure. Characterization studies of the PcAbs indicated that the titer of antiserum-1 was highest in 3 antisera, and antiserum-1 had high affinity and specificity to the parathion, dichlorvos and pirimiphos. The IC-ELISA showed an IC50 of 0.428 micro g/mL with a detection limit of 0.0125 micro g/mL to parathion. The assay also indicated that the IC50 values of pirimiphos and dichlorvos were 0.331 micro g/mL and 1.25 micro g/mL respectively, and the detection limits of pirimiphos and dichlorvos were 0.0116 micro g/mL and 0.048 micro g/mL respectively. Recoveries of parathion, pirimiphos and dichlorvos spiked into water samples ranged from 90% to 160%. The results indicated that the ELISA could be a convenient and supplemental analytical tool for monitoring OPs residues in environmental water samples.  相似文献   

9.
Abstract

Broiler chickens and swine fed furazolidone in their diet were sacrificed, and samples of liver, kidney, skin/fat and muscle were harvested and analyzed for furazolidone residue. Chickens fed 200 g of furazolidone/ton of feed were withdrawn from treatment 21, 14, 7, 5, 3, or 0 days before slaughter. Birds withdrawn from medication more than 5 days prior to slaughter had no residues in any of the tissues sampled. One of the 12 birds in each of the 5 day and 3 day withdrawal groups had detectable residues in the skin/fat. Seven of the 12 birds in the 0 day withdrawal group had residues of <2 ppb in skin/fat samples. Chickens fed 400 g furazolidone/ton of feed were withdrawn from treatment 0 days before slaughter. Residues of 0.7 to 3.5 ppb were found in the skin of these birds; residues were not found in other tissues. Swine were fed 300 g furazolidone/ton of feed for 2 weeks or 150 g/ton for 5 weeks. They were withdrawn from treatment 10, 7, 5, 3, or 0 days before slaughter. Tissue samples taken from these swine did not contain detectable furazolidone residues.  相似文献   

10.
Abstract

Paclobutrazol (PBZ) is a plant growth regulator (PGR) widely used in fruit and vegetable cultivation. However, due to the severe toxicity of PBZ, a sub-ppm level maximum residue limit (MRL) was established worldwide. Therefore, it is significant to propose a rapid, sensitive and high throughput screening method for monitoring the PBZ residues in foods. In this study, a simple and sensitive indirect competitive Enzyme-linked immunosorbent assay (icELISA) was established for PBZ detection in fruits basing polyclonal antibody. For both economy and pollution prevention, a microwave-solvent-free method was used to synthesize the PBZ hapten with high efficiency. The detection conditions, such as coating antigen concentration, antibody concentration, organic reagent concentration, ionic strength and pH, were optimized. Under the optimized conditions, this method showed high sensitivity and specificity. The detection range is 1.27-138.23?ng/mL, half-maximum inhibition concentration (IC50) is 13.26?ng/mL, and the IC20 was lower than the reported ELISAs for PBZ. Additionally, this method had high accuracy and precision. The recoveries were ranged from 88.78% to 96.80% in PBZ spiked apple samples with RSD below 4%. All the results showed that the polyclonal antibody based icELISA could be useful for PBZ screening in fruit samples.  相似文献   

11.
In-house developed ELISA was standardized to monitor atrazine residues in different environmental samples. The standard curve was linear, indicating an increase in log concentration with decrease in absorbance (%B/B0 = 1.075–0.042 Log C; r = ?0.966). The middle of the test was at 75 ng/L and the lowest detection limit at 4 ng/L. ELISA significantly correlated with the high performance liquid chromatography (HPLC) (r = 0.990). Internal validation showed good accuracy and precision. Maximum atrazine residues were present in Jehlum River water/sediments and maize/sugarcane plant roots. Most of the food samples were found to be contaminated. ELISA required less clean-up steps than HPLC, but showed matrix effect in soil/colored extracts.  相似文献   

12.
Gentamicin (Gent) is an aminoglycoside antibiotic being used in livestock sector. Gent residues could cause some genetic disorders by nonsense mutations. This study aimed to develop IgY-based ELISA for the detection of Gent in animal products. Gent was conjugated with Bovine serum albumin (BSA) by carbodiimide method for further immunization in the laying chickens. PEG-6000 extraction method was employed to extract IgY from the egg yolk. The titer of anti-Gent-IgY attained the peak of 1:256,000 after the 5th booster immunization. Checkerboard titration confirmed that, anti-Gent IgY in 1:2,000 dilution could give an Optical Density (OD) 1.0 at 2 µg mL?1 of Gent-OVA coating concentration. IgY-based indirect competitive ELISA (Ic-ELISA) showed that, the IC50 value of anti-Gent IgY was 2.69 ng mL?1 and regression curve equation was y = ?16.27x + 56.97 (R2 = 0.95, n = 3), confirming that, the detection limit (LOD, IC10 value) was 0.01 ng mL?1. Recoveries from fresh milk, pork and chicken samples were ranged from 69.82% to 94.32%, with relative standard deviation lower than 10.88%. Our results suggested that generated anti-Gent IgY antibodies can be used in routine screening analysis of Gent residues in food samples.  相似文献   

13.
In-house developed ELISA was standardized to monitor atrazine residues in different environmental samples. The standard curve was linear, indicating an increase in log concentration with decrease in absorbance (%B/B(0)=1.075-0.042 Log C; r= -0.966). The middle of the test was at 75 ng/L and the lowest detection limit at 4 ng/L. ELISA significantly correlated with the high performance liquid chromatography (HPLC) (r=0.990). Internal validation showed good accuracy and precision. Maximum atrazine residues were present in Jehlum River water/sediments and maize/sugarcane plant roots. Most of the food samples were found to be contaminated. ELISA required less clean-up steps than HPLC, but showed matrix effect in soil/colored extracts.  相似文献   

14.
A highly sensitive enzyme immunoassay is described for the detection of atrazine residues in water. Atrazine derivative was conjugated to Bovine Serum Albumin (BSA) to obtain an immunizing antigen and to Horseradish Peroxidase enzyme (POD) to obtain a marker for immunoassay. The formation of these conjugations was confirmed by UV spectroscopy as well as by gel-electrophoresis. Polyclonal antibodies were raised in rabbits by immunization with an atrazine-BSA conjugate containing 29 atrazine residues per BSA molecule. An ELISA on microtitration plates was optimized with peroxidase-atrazine conjugate. The middle of the test (50% B/Bo) was found to be at 90 ng/l, which is well below the maximum concentration permitted by the EC guidelines for drinking water. Detection limits for atrazine of about 1 ng/l could be reached. The assay did not require concentration or cleanup steps for drinking or ground water samples. Validation experiments showed good accuracy and precision. No cross-reactivities were shown by other s-triazines like terbutryn, ametryn, terbuthylazine, des-isopropylatrazine, and de-ethylatrazine except hydroxyatrazine. The latter was present at very low levels that can be calibrated/standardized before analysis or it may be considered as leftover residues of atrazine. Based on these results, it is suggested that this test can be applied to obtain fairly accurate results for atrazine concentration in water samples from different sources.  相似文献   

15.
An indirect competitive enzyme-linked immunosorbent assay (ELISA) has been developed and optimized for atrazine determination in soil at different depths (0-10, 10-20, and 20-30 cm) before and after 48 h of application, corn shoot and cow milk samples collected from Dina farm, Egypt. This assay was based on a specific polyclonal antibodies (PAb) raised by immunizing New Zealand rabbits with an immunogen prepared by coupling 3-{4-(ethylamino)-6-(isopropylamino)-1,3,5-triazine-2-yl} thiopropanoic acid to bovine serum albumin (BSA) via N-hydroxysuccinimide (NHS) active ester method. The sensitivity (estimated as IC?? value) was 17.5 μg mL?1 with a detection limit of 0.1 ng mL?1. The maximum atrazine concentration was found in soil especially in the deepest layer (325 and 890 μg kg?1 before and after application, respectively). Atrazine concentration in corn shoot was 333.28, μg kg?1 dry plant, while there was no detectable amount in milk. All samples screened by ELISA were validated by gas chromatography mass spectrometer procedure (GC/MS). Good correlation was achieved between the two methods (r = 0.997 for soil and 0.9814 for plant). This study demonstrates the utility and convenience of the simple, practical and cost-effective ELISA method in the laboratory for analysis of environmental samples. The method is ideal for the rapid screening of large numbers of samples in laboratories where access to GC/MS facilities, is limited or lacking.  相似文献   

16.
The objective of this study was to produce a generic antibody for immunoassay of fluoroquinolone drugs in meat. Two novel haptens of sarafloxacin were synthesized that were used to produce the monoclonal antibodies. The obtained monoclonal antibodies simultaneously recognized 12 fluoroquinolone drugs (sarafloxacin, diflocaxin, marbofloxacin, ofloxacin, ciprofloxacin, enrofloxacin, norfloxacin, pefloxacin, lomefloxacin, amifloxacin, enofloxacin and danofloxacin). After evaluation of different coating antigen/antibody combinations, a heterologous competitive indirect enzyme linked immunosorbent assay (ELISA) was developed to determine the 12 drugs. The crossreactivities to these analytes were in the range of 18%–113% and the limits of detection were in the range of 0.8–6.5 ng/mL depending on the compound. Eight fluoroquinolones licensed as veterinary drugs in China were fortified into blank chicken for ELISA analysis. The recoveries were in the range of 67.6%–94.6% with coefficients of variation lower than 12.4%. Therefore, this method could be used as a screen tool for routine monitoring of the residues of these fluoroquinolone drugs in animal derived foods.  相似文献   

17.
A 96-microwell enzyme-linked immunosorbent assay (ELISA) method was evaluated to determine PCDDs/PCDFs in sediment and soil samples from an EPA Superfund site. Samples were prepared and analyzed by both the ELISA and a gas chromatography/high resolution mass spectrometry (GC/HRMS) method. Comparable method precision, accuracy, and detection level (8 ng kg(-1)) were achieved by the ELISA method with respect to GC/HRMS. However, the extraction and cleanup method developed for the ELISA requires refinement for the soil type that yielded a waxy residue after sample processing. Four types of statistical analyses (Pearson correlation coefficient, paired t-test, nonparametric tests, and McNemar's test of association) were performed to determine whether the two methods produced statistically different results. The log-transformed ELISA-derived 2,3,7,8-tetrachlorodibenzo-p-dioxin values and log-transformed GC/HRMS-derived TEQ values were significantly correlated (r=0.79) at the 0.05 level. The median difference in values between ELISA and GC/HRMS was not significant at the 0.05 level. Low false negative and false positive rates (<10%) were observed for the ELISA when compared to the GC/HRMS at 1,000 ng TEQ kg(-1). The findings suggest that immunochemical technology could be a complementary monitoring tool for determining concentrations at the 1,000 ng TEQ kg(-1) action level for contaminated sediment and soil. The ELISA could also be used in an analytical triage approach to screen and rank samples prior to instrumental analysis.  相似文献   

18.
The objective of this study was to produce a generic monoclonal antibody for multi-determination of the residues of tetracycline drugs in bovine muscle and milk. Two new immunogens of doxycycline were prepared that were used to produce the monoclonal antibodies. Results showed the obtained antibodies simultaneously recognized seven tetracycline drugs (doxycycline, tetracycline, chlortetracycline, oxytetracycline, minocycline, methacycline, demeclocycline). The obtained antibodies and three coating antigens were arranged into six combinations to optimize the reagents combination. After comparison of the performances of these combinations, a heterologous indirect competitive ELISA was then used to determine the seven tetracyclines in bovine muscle and milk. The crossreactivities to the seven analytes were in the range of 47%–102% and the limits of detection were in the range of 1.5–6.9 ng/mL depending on the compound. The recoveries of the seven drugs from fortified blank samples were in the range of 75.3%–106.8% with coefficients of variation lower than 10.9%. Therefore, this method could be used as a multi-analytes screen tool for routine monitoring of the residues of these tetracycline drugs in bovine muscle and milk.  相似文献   

19.
A rapid and sensitive indirect competitive fluorescence-linked immunosorbent assay (cFLISA) method based on quantum dots as the fluorescence label coupled with secondary antibody (Ab2) for the detection of chlorpyrifos in drinking water has been developed. The cFLISA method allowed for chlorpyrifos determination in a liner working range of 15.2–205.5 ng mL?1. The 50 % inhibition value (IC50) and the limit of detection (LOD) of the cFLISA were 50.2 ng mL?1 and 8.4 ng mL?1, while the IC50 and the LOD of the conventhional enzyme linked immunosorbent assay (ELISA) were 95.3 ng- mL?1 and 16.2 ng mL?1, respectively. When the concentrations of chlorpyrifos were 200, 100 and 50 ng mL?1, the recoveries ranged from 90.8 % to 108.2 % with a coefficient of variation (CV) of 7.5 %–15.2 %. In water sample analysis, the results of cFLISA were similar to those obtained from a cELISA and a high performance liquid chromatography (HPLC) method, while the detection time by cFLISA was reduced 0.5 h compared with ELISA. It showed that cFLISA could be used as a new screening method for the detection of pesticide residue.  相似文献   

20.
Triolein-filled semipermeable membrane devices (SPMDs) were immersed at three locations along the St. Joseph River in northern Indiana for 30 days to see if the PCB content of fish from the same location could be predicted with this model device. Triolein from the SPMD's was analyzed for PCB using enzyme-linked immunosorbent assay (ELISA) and compared to residues detected in fish collected from the same locations. There was a significant difference (p < 0.05) in total PCB concentrations between SPMD samples. However, due to variability in PCB residues between species and low PCB residues in SPMDs, a direct correlation between PCBs in sportfish and SPMDs could not be determined.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号