首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Objectives The purpose of this study was to determine electromagnetic fields, electric fields, humidity, temperature, and illumination levels in hairdresser salons located in the downtown area of Aydin, Turkey. Also some health problems which could be related with the occupational factors are evaluated. Materials and methods The study was carried out in 30 hairdresser salons, all of which had been registered within the past 5 years. Electric and electromagnetic fields, illumination, temperature and humidity measurements were determined for hairdryers, hood hairdryers and depilatory heaters in the participating salons. A brief questionnaire about characteristics and the health status of hairdressers and workplace conditions was prepared and administered to the hairdressers at the salons. Results The mean electric fields of hairdryers, hood hairdryers and depilatory heaters were determined as 518 ± 74, 1,123 ± 199, and 648 ± 146 in V/m, respectively, at 5 cm from the surface of each device. These appliances generate mean electromagnetic fields in excess of 0.25 μT at 5 cm: hand-held hairdryers, 5.0 ± 0.7 μT; hood hairdryers, 1.6 ± 0.3 μT; and depilatory heaters 1.9 ± 0.6 μT. Total average of cumulative electric and electromagnetic fields, measured at a distance of 90 cm from the surface of these three devices was calculated to be 98.8 V/m and 0.5 μT, in the participating salons. Conclusions This preliminary study suggests that physical environmental factors in the salons may be contributing to the health problems of the hairdressers, and the electrical equipments in the workplaces may have cumulative electric and electromagnetic effects.  相似文献   

2.
The chemical environment that dairy farmers are exposed to during milking was investigated. Volatile organic compounds (VOCs) were analysed and identified, and the levels of formaldehyde, ammonia and carbon dioxide were measured in eight farms in northern Sweden. Both stationary and personal samples were taken. A total of 70 VOCs were identified from the adsorbent samples, with p-cresol, 2-butanone, ethyl acetate, alpha-pinene and delta 3-carene occurring at the highest levels. All monitored levels were significantly lower for compounds having a stated highest occupational exposure level (OEL). Using multivariate techniques some differences in the composition of the workplace air between and within the farms were found. No difference was found between personal exposure and the surrounding environment in the cowshed.  相似文献   

3.
室内人造板材制品释放挥发性有机化合物研究   总被引:5,自引:0,他引:5       下载免费PDF全文
通过对浸渍纸层压木质地板、实木地板、实木复合地板、竹地板、胶合板、细木工板6种共39个人造板材中的挥发性有机物进行定性研究,确定了家用人造板材制品释放的主要挥发性有机物种类,以及人造板材制品中芳香族化合物的主要来源.通过对5间购入新家具的室内环境空气中甲醛、苯、甲苯和总挥发性有机化合物(TVOC)的定量分析,确定了人造板材制品释放挥发性有机化合物的污染水平.研究表明,人造板材释放的挥发性有机化合物以烯烃、芳香族、酯类化合物为主,其中芳香族化合物主要来源于胶合板和细木工板,室内人造板材制品的使用可以使室内环境空气中挥发性有机化合物的质量浓度显著提高.  相似文献   

4.
During a monitoring campaign concentrations of volatile organic compounds (VOCs) were measured in indoor air of 79 dwellings where occupants had not complained about health problems or unpleasant odour. Parameters monitored were the individual concentration of 68 VOCs and the total concentration of all VOCs inside the room. VOCs adsorbed by Tenax TA were then analysed by means of thermal desorption, gas chromatography and mass spectrometry. The analytical procedure and quantification was done according to the recommendation of the ECA-IAQ Working Group 13 which gave a definition of the total volatile organic compound (TVOC) concentration. Using this recommendation TVOC-concentrations ranged between 33 and 1600 microg m(-3) with a median of 289 microg m(-3). Compounds found in every sample and with the highest concentrations were 2-propanol, alpha-pinene and toluene. Save for a few samples, all concentrations measured have been a factor 2 to 10 lower, compared to data from similar studies. Only a few terpenes and aldehydes were found exceeding published reference data or odour threshold concentrations. However, it has been found that sampling and analysing methods do have a considerable impact on the results, making direct comparisons of studies somewhat questionable. 47% of all samples revealed concentrations exceeding the threshold value of 300 microg TVOC m(-3) set by the German Federal Environmental Agency as a target for indoor air quality. Using the TVOC concentration as defined in the ECA-IAQ methodology is instrumental in assessing exposure to VOCs and identifying sources of VOCs. The background concentrations determined in this study can be used to discuss and interpret target values for individual and total volatile organic compounds in indoor air.  相似文献   

5.
Several hundred chemical compounds were found in workroom environments in the rubber industry, but most of the published exposure data relate to the production of tyres; information from the "non-tyre" sections are very limited, if any. This study was carried out to identify chemical substances and measure their air concentrations in the repair shop of a brown coal mine in which damaged rubber conveyor belts were repaired. GC-MS and HPLC analysis of stationary air samples resulted in identification of aliphatic and aromatic hydrocarbons to C12, PAHs, alcohols, phenols, ketones, heterocyclic nitrogen and sulfur compounds. Quantitative evaluation of occupational exposure included determination of organic compound vapours collected on charcoal (GC-MSD), polycyclic aromatic hydrocarbons (HPLC), N-nitrosoamines and other amines (GC-NPD) and DNPH derivatives of aldehydes (HPLC) in the breathing zone of workers representing all job titles. The concentrations of investigated compounds were very low. Carcinogenic substances: N-nitrosoamines, benzene, PAHs were not present in workroom air in concentrations exceeding limits of detection of the analytical methods being applied; concentrations of methylisobutylketone, tetrachloroethylene, naphtha, aromatic hydrocarbons, phthalates and aldehydes were much lower than the respective occupational exposure limit values. The results indicate much lower exposure than that reported in the production of tyres and other fabricated rubber products.  相似文献   

6.
Carbon monoxide (CO) is one of the six criteria air pollutants related to urbanization and has a wide range of health effects. The study measured and compared the exhaled CO levels among commuters and roadside vendors in potentially heavy and low traffic volume areas of Karachi, a megacity in Pakistan. Saddar town [areas of M. A. Jinnah Road (Tibet Center, Denso Hall) and Empress Market] was selected to represent an area of high traffic volume and the suburban town of Gadap (Gadap and Gulshan-e-Maymar) was selected to represent an area of no or low traffic volume. The study compared the CO exposure of commuters and roadside vendors in high and low traffic volume in Karachi. CO exposure was measured in expired air using the breath analyzer module of Bacharach Monoxor-II, USA. A total of 326 individuals (115 commuters and 211 stationary roadside vendors) from Saddar town (n?=?193) and Gadap town (n?=?133) were selected. In addition, CO levels in ambient air in the same areas, using portable CO analyzer (Bacharach, Monoxor-II, USA), were measured. The mean ambient CO level at Saddar town was 15.6 (SE ± 2.6) ppm compared to 3.3 (SE ± 0.3) ppm at Gadap town. The mean CO level in expired air was significantly higher among nonsmokers at Saddar town (12.8 ± 0.5 ppm) compared to the nonsmokers at Gadap town (7.8 ± 0.4 ppm). The mean CO level in expired air among smokers was twice that of nonsmokers (21.6 vs. 10.6 ppm). CO in expired air was greater among high traffic volume commuters and roadside stationary population in Karachi, Pakistan. The population in Karachi is exposed to high concentration of air pollutants. These pollutants need to be characterized for health effects and interventions needs to be developed.  相似文献   

7.
Air samples were collected in Izmir, Turkey at two (suburban and urban) sites during three sampling programs in 2002 and 2004 to determine the ambient concentrations of several monoaromatic, chlorinated and oxygenated volatile organic compounds (VOCs). Samples were analyzed for 60 VOCs using gas chromatography/mass spectrometry and 28 compounds were detected in most samples. On the average, urban air VOC concentrations were about four times higher than those measured at the suburban site. Toluene (40.6%) was the most abundant compound in suburban site and was followed by benzene (7.4%), o,m-xylene (6.5%), and 1,2-dichloroethane (5.1%). In urban site, toluene (30.5%), p-xylene (14.9%), o,m-xylene (11.4%), and ethyl benzene (7.2%) were the dominating compounds in summer. In winter, toluene (31.1%), benzene (23.9%), 1,2-dichloroethane (9.5%), and o,m-xylene (8.2%) were the most abundant compounds. Receptor modeling (positive matrix factorization) has been performed to estimate the contribution of specific source types to ambient concentrations. Six source factors (gasoline vehicle exhaust, diesel vehicle exhaust+residential heating, paint production/application, degreasing, dry cleaning, and an undefined source) were extracted from the samples collected in the urban site. Three source factors (gasoline vehicle exhaust, diesel vehicle exhaust, and paint production/application) were identified for the suburban site.  相似文献   

8.
Hourly concentrations of ozone (O(3)), 55 volatile organic compounds (VOCs, ozone precursors) and nitrogen oxides (NOx) were measured at an upwind urban site, a downwind suburban site, and a rural site in central Taiwan, from January 2003 to December 2006. VOC and NOx mean concentrations showed a gradient from high to low across the urban (56 ppb and 34 ppb), suburban (38 ppb and 27 ppb) and rural sites (25 ppb and 21 ppb) but a reverse gradient in ozone across these sites (24, 27, and 29 ppb, respectively). Although there was about twice the difference in VOC concentrations between the urban and rural sites, nearly 65% ozone formation potential was contributed to by the same 9 VOCs. Seasonal patterns showed peak ozone levels in autumn and minima in summer at the urban site, but minima in winter at the downwind suburban and rural sites. Ozone precursor levels, on the other hand, were lowest in summer and highest in winter. The diurnal pattern showed that ozone levels peaked one hour later at the rural site than at the urban site. The ethylbenzene to m,p-xylene ratio, an indicator of the age of the air mass, increased from 0.4 at the urban site to 0.6 at the suburban site and 0.8 at the rural site during daily peak ozone times. This finding suggests the transport of ozone and precursors from upwind to downwind producing elevated ozone levels in the suburban and rural areas. Ozone episodes occurred mostly in days with a mean midday UV index of 6.5 (1 UV index=100 J m(-2)) and wind speed at 1.3 m s(-1) at all three sites.  相似文献   

9.
以某高校新生发样为研究样本,将生源地分为东北、西北、西南、华北、华南、华中、华东7个地域,采用电感耦合等离子发射光谱法对发样中所含铬、铜、镍、铅、锌进行测定,通过非参数检验及偏相关性检验分析不同地区发样中重金属含量与性别、身体质量指数(BMI)的关系。结果显示,所采集发样中铬、铜、镍、铅、锌的含量变化范围依次为0.22~101.84、0.36~112.24、0.70~128.75、1.39~136.13、1.12~719.50μg/g;发样中重金属浓度的地区排序为东北>华东>华北>西北>华中>西南>华南。聚类分析和主成分分析结果显示,不同地区发样中重金属的来源有所差异:东北、西北、华北地区发样中重金属可能主要来源于燃煤、工业生产过程、机动车排放,方差贡献率分别为39.47%、25.78%、22.89%;华中、华东、西南、华南地区发样中重金属可能主要来源于工业生产过程、机动车排放、冶金化工过程,贡献率分别为47.76%、27.51%、18.24%。相关性检验显示,男性发样内铬、铜、镍、铅含量高于女性。其中,偏胖或偏瘦女性存在较高的铅暴露风险;40.2%的男性发锌含量低于正常值下限,24.4%的女性发锌含量低于正常值下限,且偏瘦女性发内缺锌现象显著;男、女发铜含量高于正常值上限的比例分别为91.8%、85.6%,存在不同程度的铜暴露风险。  相似文献   

10.
It is costly to sample all air pollutants of a general community. Air sampling should be conducted based on a practical assessment strategy and monitoring plan. In Hong Kong, the Environmental Protection Department (HKEPD) launched an Indoor Air Quality (IAQ) certification scheme to grade workplace IAQ as 'Excellent' or 'Good' by measuring the levels of nine common indoor air pollutants, namely carbon dioxide (CO(2)), carbon monoxide (CO), respirable suspended particulates (RSP), nitrogen dioxide (NO(2)), ozone (O(3)), formaldehyde (HCHO), total volatile organic compounds (TVOC), radon (Rn), and airborne bacteria count (ABC). Although average office IAQ performance has been improved since the implementation of this certification scheme, there are still resource issues and technical difficulties. To streamline the assessment of office IAQ performance, this study proposes a simple index of IAQ benchmarks formulated in compliance with the HKEPD requirements. In particular, three of the nine listed common air pollutants were selected as the 'representatives' for the overall satisfactory IAQ. Together with the assessment results of 422 Hong Kong air-conditioned offices, the index was evaluated in terms of test sensitivity, specificity and predictive values. Proved to be feasible to describe the IAQ of some air-conditioned offices, this IAQ index would be a useful tool for policymakers, building owners and professionals to quantify IAQ performance in offices and to make decisions on resources and manpower management for efficient mitigation actions.  相似文献   

11.
The main purpose of this work was the preliminary qualitative study of organic compounds in wastewaters of swine slaughterhouses. The samples were collected in a local abattoir and submitted to Liquid-Liquid Extraction (LLE) and Solid-phase Extraction (SPE) with XAD-4TM resin as stationary phase. The instrumental analysis was performed by Gas Chromatography with Mass Spectrometer Detector (GC/MSD). The compounds present in the LLE and SPE extracts were identified by the GC/MSD library (Wiley). The results pointed out that SPE and LLE can extract practically the same classes of compounds at the same amounts. LLE works well for the extraction of polar organic compounds, with acidified samples, while SPE presents a better performance for the extraction of less polar organic compounds. Aldehydes were main class of the compounds extracted by SPE and LLE and decenal was the major aldehyde identified. Fatty alcohols and carboxylic acids were also identified but in minor proportions.  相似文献   

12.
综合评价室内空气质量初探   总被引:7,自引:2,他引:5  
阐述了现行室内空气质量评价方法存在的不足,通过分析比较,确定了利用计权型多因子环境质量评价指数进行室内空气质量的综合评价方法.根据当前由于室内装修引起的室内空气污染特点,选择了甲醛、氨气、苯、甲苯、二甲苯和总挥发性有机物等6项指标作为评价因子,各评价因子的权重系数用其危害等级计算得到.  相似文献   

13.
The main objective of this work was to quantify and characterize the major indoor air contaminants present in different stages of a municipal WWTP, including microorganisms (bacteria and fungi), carbon dioxide, carbon monoxide, hydrogen sulfide ammonia, formaldehyde, and volatile organic compounds (VOCs). In general, the total bacteria concentration was found to vary from 60 to >52,560 colony-forming units (CFU)/m3, and the total fungi concentration ranged from 369 to 14,068 CFU/m3. Generally, Gram-positive bacteria were observed in higher number than Gram-negative bacteria. CO2 concentration ranged from 251 to 9,710 ppm, and CO concentration was either not detected or presented a level of 1 ppm. H2S concentration ranged from 0.1 to 6.0 ppm. NH3 concentration was <2 ppm in most samples. Formaldehyde was <0.01 ppm at all sampling sites. The total VOC concentration ranged from 36 to 1,724 μg/m3. Among the VOCs, toluene presented the highest concentration. Results point to indoor/outdoor ratios higher than one. In general, the highest levels of airborne contaminants were detected at the primary treatment (SEDIPAC 3D), secondary sedimentation, and sludge dehydration. At most sampling sites, the concentrations of airborne contaminants were below the occupational exposure limits (OELs) for all the campaigns. However, a few contaminants were above OELs in some sampling sites.  相似文献   

14.
The aim of this study was to investigate the relation between two toxic volatile organic compounds, 1,3-butadiene and benzene, and a commonly used indicator of vehicle exhaust fumes, NO(2). This was to see if NO(2) can be used to indicate personal exposure to carcinogenic substances or at least estimate ambient levels measured at a stationary point. During the winter of 2001, 40 randomly selected persons living in the City of Umea (in the north of Sweden) were recruited to the study. Personal measurements of 1,3-butadiene, benzene and NO(2) were performed for one week, and were repeated for 20 of the 40 participants. Additional information was gathered using a diary kept by each participant. During the same time period weekly stationary measurements were performed at one urban background station and one street station in the city centre. The results from the personal measurements showed a negligible association of NO(2) with 1,3-butadiene (r= 0.06) as well as with benzene (r= 0.10), while the correlation coefficient between 1,3-butadiene and benzene was high and significant (r= 0.67). In contrast to the personal measurements, the stationary measurements showed strong relations between 1,3-butadiene, benzene and NO(2) both within and in-between the street and urban background station. This study supports NO(2) as a potential indicator for 1,3-butadiene and benzene levels in streets or urban background air, while the weak relations found for the personal measurements do not support the use of NO(2) as an indicator for personal 1,3-butadiene and benzene exposure.  相似文献   

15.
Multivariate techniques have been applied to the set of dataobtained after one year sampling of volatile organic compounds(VOCs), including volatile aldehydes in the area of Madrid inorder to evaluate the possible correspondence among groups ofanalysed compounds, as far as modelling of different emissionsources in relation to location and season. The measurements were carried out at four sites in Madrid, characteristic for urban and suburban areas. Additionally, as reference, a rural area 100 km far from the city was considered. Results of correlation analysis, factor and cluster analysis are presented.Higher correlations were found between variables related withtraffic emissions. Factor analysis results showed two mainsignificant variables related to anthropogenic and biogenicemissions respectively. In relation to cluster analysis, samples were grouped according to sampling site and seasonal variations.  相似文献   

16.
This study evaluated the relationship between the breath concentrations of, and personal exposure to, toluene, xylene and ethylbenzene of thirty workers from ten gasoline stations. Personal exposure air samples and workplace samples were collected simultaneously. Each subject provided a sample of exhaled breath after his or her personal exposure air was sampled. Twenty-five personal air, 17 workplace and 30 breath samples were collected in this study. Results indicated that breath concentrations of toluene and xylene were significantly correlated with personal monitoring concentrations. Furthermore, multiple regression analysis showed that exhaled toluene levels were highly influenced by personal toluene concentrations and the amount of personal gasoline sold (r2 = 0.762), while exhaled xylene levels depended on wind speed and personal xylene exposure concentrations (r2 = 0.665). Exhaled ethylbenzene levels were too low to present a relationship between concentrations and personal exposure levels. The exhaled toluene, xylene and ethylbenzene concentrations ranged from 4.3 to 41.8, 0.9 to 13.9, and 0.2 to 6.5 ppb, and the corresponding personal monitoring concentrations ranged from 60.3 to 572.3, 16.4 to 156.6, and 10.7 to 136.6, respectively. The average number of symptoms per person, according to neurotoxic questionnaire 16 (abbreviated as Q16) was 4.1 and six workers showed over six symptoms in Q16. This study suggests that exhaled toluene and xylene levels are suitable for use as biological exposure indices even at the ppb-level of exposure. Gasoline service workers are exposed to high levels of volatile organic compounds (VOCs) and the potential threats to their neurological systems deserve further investigation.  相似文献   

17.
This study describes occupational exposure to acrylates and other solvents during nail sculpturing, including comparative measurements of the exposure using four different sculpturing methods: The acrylic method, the UV-gel method, the acrylic powder method and the resin method. Thirty-two nail technicians working in 22 different salons participated in the study. In total, 92 measurements were performed, comprising 70 solvent measurements and 22 measurements of ethyl 2-cyanoacrylate. The solvents most frequently present in all samples were acetone, ethyl acetate, toluene and n-butyl acetate, measured in 96%, 94%, 91% and 81% of the samples, respectively. The study shows that the overall solvent exposure was low, with all measurements calculated as the additive effect (n = 70) below 20% of the OEL (arithmetic mean 0.06 and range 0.01-0.19). No statistically significant difference between sculpturing methods were observed (p = 0.05).  相似文献   

18.
Brominated organic and inorganic by-products are generated during ozonation of groundwater containing high bromide concentrations. This study measured concentrations of bromate, bromoform, bromoacetic acids, bromoacetonitriles, bromoacetone, 2,4-dibromophenol and aldehyde generated by ozonation. The potential mutagenicity of ozonated waters was assessed using the Ames and Microtox tests. Test results for the 18 ozonated groundwater samples demonstrate that bromate formation is associated with high pH, bromide and alkalinity content, low levels of dissolved organic carbon (DOC) and ammonia, and low alkalinity. Brominated organic by-products were correlated with high bromide ion and natural organic matter content, and low ammonia concentrations. The Ames test results demonstrate that all extracts from ozonated water have mutagenic activity; however, the 18 raw groundwater samples had no mutagenicity. The Microtox test results also show that the ozonated water samples were highly toxic. Generally, both bromide and DOC content promoted the formation of ozonation by-products and mutagenicity. Controlling of bromide and DOC concentrations is an effective method of reducing potential by-product formation and eliminating mutagenicity problems associated with groundwater ozonation.  相似文献   

19.
The Egyptian Red Sea environment especially along El-Sokhna area to the Suez refineries (Suez) is severely contaminated with organic compounds, as well as overfishing. This may be well contributory to recent serious declines in fish stocks. Fish embryos are also particularly vulnerable to oil exposure, even at extremely low concentrations of less than one part per billion. Consequently, even traces of oil pollution at levels often considered safe for wildlife can cause severe damage to fish. Sixteen polycyclic aromatic hydrocarbons (PAHs) were investigated in ten fish species of aquatic species by high performance liquid chromatography (HPLC). The compositions of PAHs determined in all samples were measured in order to use them as chemical markers for identifying different sources of PAH pollutants in the studied region. The total content of these16 PAHs ranged from 399.616 up to 67,631.779 ng/g wet weight. The data show that these values are considered to be alarmingly high enough to cause lethal toxicity effect by accumulation. All studied aquatic species samples are characterized by relatively high concentrations of the six-membered ring PAHs. The origin of PAHs in the collected samples is either petrogenic, biogenic, or mixed petrogenic and biogenic.  相似文献   

20.
对上海市某综合型城市地下空间空气进行采样、监测,得到CO 2、TVOC、甲醛、微生物、PM 10、PM 2.5等6类污染物的特征分布,基于国内外不同的空气质量标准作分析比较。结果表明,该典型综合型地下空间的空气污染情况较普遍,其中甲醛、TVOC污染较为突出,平均浓度超标倍数分别为1.056倍、3.755倍;共发现9种潜在致病菌属,占总数的0.893%。地下空间污染物的累积与内部建筑的设计、装修、功能属性、空调系统等众多因素有关。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号